muv nt eng 50hz - salmson.com€¦ · muv 0 137 14 qm3/h hm pumping of clean, non-muddy liquids in...

8
MUV 0 137 14 Qm 3 /h Hm Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors : - Supply - Boosting - Watering - Irrigation - Washing stations - Heating - Air conditioning And for incorporation into all modular systems. Abstraction from wells, springs, rivers, ponds... OPERATING RANGES Flow rates of up to: 14 m 3 /h Manometric heads of up to: 137 m CE Max. operating pressure: 10 bar Max. intake pressure: 6 bar Temperature range: – 15° to + 90°C Max. ambient temperature: + 40°C DN (nominal diameter) of ports: G1”to G1” 1/2 Reference MEI*: ≥ 0,10 *Minimum Efficiency Index VERTICAL MULTI-STAGE PUMPS 2 pole - 50 Hz APPLICATIONS ADVANTAGES - Extended shaft design allows for opti- mised alignment - Stainless steel impellers and stages, cast iron pump housing - Impeller rings and seals between very thick cells: impervious to thermal expan- sion and eliminates the risk of seizing; - Standardised mechanical seal +90°C N.T. N o 141-13/ENG. - Ed.4/10-14 • MUV Certified 1 MUV

Upload: lamhanh

Post on 30-Sep-2018

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MUV NT ENG 50Hz - salmson.com€¦ · MUV 0 137 14 Qm3/h Hm Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors : - Supply - Boosting-Watering

MUV

0

137

14 Qm3/h

Hm

Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors :- Supply - Boosting- Watering - Irrigation - Washing stations - Heating - Air conditioning

And for incorporation into all modular systems.Abstraction from wells, springs, rivers, ponds...

OPERATING RANGESFlow rates of up to: 14 m3/hManometric heads of up to: 137 m CEMax. operating pressure: 10 barMax. intake pressure: 6 barTemperature range: – 15° to + 90°CMax. ambient temperature: + 40°CDN (nominal diameter) of ports: G1”to G1”1/2

Reference MEI*: ≥ 0,10*Minimum Efficiency Index

VERTICAL MULTI-STAGE PUMPS

2 pole - 50 Hz

APPLICATIONS

ADVANTAGES- Extended shaft design allows for opti-mised alignment

- Stainless steel impellers and stages, cast iron pump housing

- Impeller rings and seals between very thick cells: impervious to thermal expan-sion and eliminates the risk of seizing;

- Standardised mechanical seal +90°C

N.T. No 141-13/ENG. - Ed.4/10-14

• MUV

Certified

1

MUV

Page 2: MUV NT ENG 50Hz - salmson.com€¦ · MUV 0 137 14 Qm3/h Hm Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors : - Supply - Boosting-Watering

0 2 4 6 8 10 12 140

20

40

60

80

100

120

MUV 102-905 - 50 Hz

MUV102-112

MUV302-312

MUV502-509

MUV902-905

Hm

Qm3/h

DESIGN• Hydraulic part- Vertical, multi-stage, centrifugal, with 2 to 12 stages.

- Vertical axis, in-line suction/delivery orifices in the lower part

- Impellers fitted directly onto the extended motor shaft.

- Standardised mechanical seal ensures leak-tightness of shaft passage.

• Motor- Standard ventilated- With extended shaft end- Rotor-shaft guide bearings lubricated for life.

Rotation speed: 2900 rpmThree-phase winding: 230-400 VSingle-phase : 230 VFrequency : 50 Hz (optional 60 Hz)Insulation class: 155 (F)Protection class: IP 54

BASIC CONSTRUCTIONMain parts MaterialPump casing EN GJL250 Impellers 304 stainless steelCells (stage housing) 304 stainless steelPump shaft Stainless steelCell centring device 304 stainless steelMechanical seal Carbon/Silicon carbideO-rings EPDM ethylene propyleneFixing-support bearing EN GJL250

HYDRAULIC PRESELECTION RANGE

IDENTIFICATIONMUV 10 2 - O E - T / 2 / 6 / OEM / XX / B

Pump family

Nominal flowrate in m3/h (at 50 hz / 2 poles)

Number of impellers

O = PN16 oval flanges

E = EPDM gasket

M = Single-phase / T = Three-phase

2 = 2 pole

Nothing = 50 Hz / 6 = 60 Hz

Original Equipment Manufacturer

Technical definition code

Technical definition code

2

MUV

Page 3: MUV NT ENG 50Hz - salmson.com€¦ · MUV 0 137 14 Qm3/h Hm Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors : - Supply - Boosting-Watering

SECTIONAL DIAGRAM

Designation reference noSuction housing 1130Stage housing with interstage crossover 1150Stage housing without interstage crossover 1160Impeller 2250Impeller spacer 2410Shaft sleeve spacer 2460aMechanical seal support ring 2460bImpeller thickness washer 2460dImpeller/snap ring support rin 2520Thrower 2540Shaft end washer 2911a/bStage housing with bearing 3044

Designation reference noLantern ring mount 3180Shaft sleeve for bearing 3400Mechanical seal 4220/4240 •friction faces •membrane •springO-rings 4610a/b/cPlugs 6515/65211/2 snap ring 6545M8 screws (motor stud bolts) 6571Equipped motor casing 8110Rotor shaft 9220

Designation reference noTerminal cover gasket 9460Fan 9820Fan cover 9822Terminal cover 9825Rear bearing shroud 9831Capacitor 9860Shaft end nut 9923aSpring washer 9944Spring pin 9966

3

MUV

Page 4: MUV NT ENG 50Hz - salmson.com€¦ · MUV 0 137 14 Qm3/h Hm Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors : - Supply - Boosting-Watering

0

10

20

30

40

50

60

70

80

90

100

110

0,5 1,0 1,5 2,0 2,5 3,0

0 0,2 0,4 0,6 0,8

010203040

0,5 1,0 1,5 2,0 2,5 3,002468

0

0,2

0,4

0,6

0,8

1,0

0,5

0

0

0 1,0 1,5 2,0 2,5 3,0

112

110

109

108

107

106

105

104

103

102

112

110109

106105

104103

102

107108

MUV 102-112 - 50 Hz

Q/l/sηp % NPSH

NPSH

ηp

Hm

P2 kW

Qm³/h

Qm³/h

Qm³/h

0

20

40

60

80

100

120

1 2 3 4 5 6 7 8

0

0

0

0

0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2,0 2,2

0

20

40

1 2 3 4 5 6 7 80

4

8

0

0,5

1,0

1,5

2,0

2,5

1 2 3 4 5 6 7 8

509

508

507

506

505

504

503

502

507506

505504

502

508

503

509

MUV 502-509 - 50 Hz

ηp %

Hm

P2 kW

Qm³/h

Qm³/h

Qm³/h

Q/l/s NPSH

NPSH

ηp

0

20

40

60

80

100

120

1 2 3 4 5

0

0

0

0

0,2 0,4 0,6 0,8 1,0 1,2 1,4

010203040

1 2 3 4 502468

0

0,5

1,0

1,5

1 2 3 4 5

MUV 302-312 - 50 Hz312

310

309

308

307

306

305

304

303

302

312

310309

308307306

305304303302

ηp %

Hm

P2 kW

Qm³/h

Qm³/h

Qm³/h

Q/l/s NPSH

NPSH

ηp

0

10

20

30

40

50

60

70

80

2 4 6 8 10 12 14

0

0

0

0

0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0

0

20

40

60

2 4 6 8 10 12 140

1

2

3

0

0,5

1,0

1,5

2,0

2,5

2 4 6 8 10 12 14

MUV 902-905 - 50 Hz

905

904

903

902

905

904

903

902

ηp %

Hm

P2 kW

Qm³/h

Qm³/h

Qm³/h

Q/l/s NPSH

NPSH

ηp

HYDRAULIC PERFORMANCE

4

MUV

Page 5: MUV NT ENG 50Hz - salmson.com€¦ · MUV 0 137 14 Qm3/h Hm Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors : - Supply - Boosting-Watering

INSTALLATION DIAGRAMS• Flooded suction pump on storage tank or mainswater system (with low-water protection system)

• Pump in suction mode

0,10m

min

min. 0,70m

HA

HC

Low level

High levelMains water supply

Strainer

Strainer foot valve

5

MUV

Page 6: MUV NT ENG 50Hz - salmson.com€¦ · MUV 0 137 14 Qm3/h Hm Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors : - Supply - Boosting-Watering

H

130187 215

252

100

80

M12

H

Ø MX

19,5

4 x Ø 14

MUV 9 - 6"PN16 - D50

100162

M10

4 x Ø 14

Ø MX

MUV 1/3/5 - 6"PN16 - D32

75180212204

50

MUV 1/3 : Rp 1"MUV 5 : Rp 1"1/4

248

Rp 1"1/2

TYPE P2 Rendement selon charge (%) 1x 230 3x230 3x400 Pmax H M X Poids µF DN

kW 4/4 3/4 2/4 A A A Bar mm mm mm kg (version Mono)

MUV102 0,37 - - - 4 1,7 1 10 418 121 110 17,5 15 32MUV103 0,37 - - - 4 1,7 1 10 418 121 110 17,8 15 32MUV104 0,37 - - - 4 1,7 1 10 418 121 110 18,1 15 32MUV105 0,55 - - - 4 3,1 1,8 10 438 121 110 18,4 15 32MUV106 0,55 - - - 4 3,1 1,8 16 458 121 110 18,7 15 32MUV107N 0,75 79 78,6 75,1 4,7 3,1 1,8 16 485 136 118 21,9 20 32MUV108N 0,75 79 78,6 75,1 4,7 3,1 1,8 16 525 136 118 22,2 20 32MUV109N 1,1 80,1 80,2 77,6 7,5 4,2 2,4 16 525 136 118 22,5 25 32MUV110N 1,1 80,1 80,2 77,6 7,5 4,2 2,4 16 545 136 118 22,8 25 32MUV112N 1,1 80,1 80,2 77,6 7,5 4,2 2,4 16 585 136 118 23,3 25 32MUV302 0,37 - - - 4 1,7 1 10 410 121 110 17,6 15 32MUV303 0,55 - - - 4 3,1 1,8 10 410 121 110 17,9 15 32MUV304N 0,75 79 78,6 75,1 4,7 3,1 1,8 10 441 136 118 21,3 20 32MUV305N 0,75 79 78,6 75,1 4,7 3,1 1,8 16 465 136 118 21,7 20 32MUV306N 1,1 80,1 80,2 77,6 7,5 4,2 2,4 16 489 136 118 20,4 25 32MUV307N 1,1 80,1 80,2 77,6 7,5 4,2 2,4 16 513 136 118 22,4 25 32MUV308N 1,5 82,1 81,6 78,4 9,6 5,6 3,3 16 544 156 126 25,7 40 32MUV309N 1,5 82,1 81,6 78,4 9,6 5,6 3,3 16 592 156 126 26,1 40 32MUV310N 1,5 82,1 81,6 78,4 9,6 5,6 3,3 16 592 156 126 26,5 40 32MUV312N 2,2 83,4 84 82,9 - 7 4,1 16 640 156 126 27,2 - 32MUV502 0,55 - - - 4 3,1 1,8 10 410 121 110 17,7 15 32MUV503N 0,75 79 78,6 75,1 4,7 3,1 1,8 10 417 136 118 21,1 20 32MUV504N 1,1 80,1 80,2 77,6 7,5 4,2 2,4 10 441 136 118 21,5 25 32MUV505N 1,1 80,1 80,2 77,6 7,5 4,2 2,4 16 465 136 118 21,8 25 32MUV506N 1,5 82,1 81,6 78,4 9,6 5,6 3,3 16 496 156 126 25,2 40 32MUV507N 1,5 82,1 81,6 78,4 9,6 5,6 3,3 16 520 156 126 25,6 40 32MUV508N 2,2 83,4 84 82,9 - 7 4,1 16 544 156 126 26,0 - 32MUV509N 2,2 83,4 84 82,9 - 7 4,1 16 592 156 126 26,3 - 32MUV902N 0,75 79 78,6 75,1 4,7 3,1 1,8 10 463 136 118 23,5 20 50MUV903N 1,1 80,1 80,2 77,6 7,5 4,2 2,4 10 463 136 118 23,9 25 50MUV904N 1,5 82,1 81,6 78,4 9,6 5,6 3,3 10 500 156 126 27,3 40 50MUV905N 2,2 83,4 84 82,9 - 7 4,1 16 530 156 126 27,8 - 50

ELECTRICAL AND DIMENSIONAL SPECIFICATIONS

TYPE P2 Efficiency according to load % 1x 230 3x230 3x400 Pmax H M X Weight µF DN

kW 4/4 3/4 2/4 A A A Bar mm mm mm kg (single-phase version)

6

MUV

Page 7: MUV NT ENG 50Hz - salmson.com€¦ · MUV 0 137 14 Qm3/h Hm Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors : - Supply - Boosting-Watering

RECOMMENDED ACCESSORIES FEATURESa) Electrical-“T” types: 230-400 V - 50 Hz three-phase - M” types: - 230 V - 50 Hz single-phase with capacitor integrated into the terminal box.- Three-phase motors MUST be protected by a slave switch.

- Stuffing box used for connections to the motor terminal box.

b) Fitting- On solid base using foundation bolts.- Installation of pump in suction mode with compulsory strainer foot valve, or flooded suction mode on storage tank or mains water system with low water protection kit.

- Connection to pump via a flexible hose or rigid piping.

- The installation must allow for the protection of the pump against adverse weather condi-tions and frost (avoid direct exposure to rain or sun).

c) PackagingPump delivered in cardboard packaging, wit-hout connection fittings.

OPTIONS AND ACCESSOIRES • Shut-off valves• Non-return valves• Strainer foot valve• Vibration-damping sleeves• Suction kit• Bladder or galvanised tanks• Surge tanks• ME low-water protection kit• ACSON: on/off control and low-water protec-tion device

• Protective slave switch for three-phase motor…

• ACSON: on/off control and low-water protection device.

•Protective slave switch for three-phase motor

• Strainer foot valve • Non-return valve

• Shut-off valve • Vibration-damping sleeves

• Vibration-damping sleeves

• Surge tank

• Bladder tank

7

MUV

Page 8: MUV NT ENG 50Hz - salmson.com€¦ · MUV 0 137 14 Qm3/h Hm Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors : - Supply - Boosting-Watering

NOTES

8

MUV