4
ADVANTAGES Quiet running High level of performance in a compact size Multi-voltage power supply input Stable vacuum in the transfer area to the turbomolecular pump Fast evacuation to deep vacuum by automatic switching from parallel to serial operation POSSIBLE AREAS OF USE Can be used as roughing pump for turbomolecular pumps – i.a. for surface finishing Instrumental analysis especially in the field of spectroscopy Vacuum drying oven PERFORMANCE DATA Series model N 950.50 Material design KNE-W KNDC-B Pump head PPS Diaphragm PTFE-coated Valve plate FPM Flow rate at atm. pressure (l/min) 55.0 Ultimate vacuum (mbar abs.) 2 Max. operating pressure (bar rel./psig) 0.5/7.3 Permissible ambient temperature (ºC) +10 ... +40 Permissible media temperature (ºC) +5 ... +40 Weight (kg/lbs) 7.4/16.3 6.5/14.3 ELECTRICAL DATA Voltage (V) 100–240 24 Motor Brushless DC motor with AC power supply Brushless DC motor Protection class motor IP 20 Frequency (Hz) 50–60 - Power P 1 (W) 140 120 I max (A) 1.90 5.00 N 950.50 SERIES VACUUM PUMPS N 950.50 KNE-W – with multiple- voltage power supply input N 950.50 KNDC-B with brushless DC motor f l e x i b l e c u s t o m -f it c o s t - e f f e c t i v e K N F M o d u l ar S y s t e m Please visit our website www.knf.com to get more information

Upload: others

Post on 08-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: N 950.50 SERIES VACUUM PUMPS - KNFAuspumpkurve10-liter-Daten N950.50 KNBC-B; KNE-W Saugvermögen Daten N950.50 KNBC-B; KNE-W 0.1 1 10 100 1000 pressure in mbar 0.01 0.1 1 10 suction

ADVANTAGES●● Quiet running

●● High level of performance in a compact size

●● Multi-voltage power supply input

●● Stable vacuum in the transfer area to the turbomolecular pump

●● Fast evacuation to deep vacuum by automatic switching from parallel to serial operation

POSSIBLE AREAS OF USE●● Can be used as roughing pump

for turbomolecular pumps – i.a. for surface finishing

●● Instrumental analysis – especially in the field of spectroscopy

●● Vacuum drying oven

PERFORMANCE DATASeries model N 950.50Material design KNE-W KNDC-BPump head PPSDiaphragm PTFE-coated Valve plate FPMFlow rate at atm. pressure (l/min) 55.0Ultimate vacuum (mbar abs.) 2Max. operating pressure (bar rel./psig) 0.5/7.3Permissible ambient temperature (ºC) +10 ... +40Permissible media temperature (ºC) +5 ... +40Weight (kg/lbs) 7.4/16.3 6.5/14.3

ELECTRICAL DATA Voltage (V) 100–240 24Motor Brushless DC motor with AC power supply Brushless DC motorProtection class motor IP 20Frequency (Hz) 50–60 -Power P1 (W) 140 120Imax (A) 1.90 5.00

N 950.50 SERIESVACUUM PUMPS

N 950.50 KNE-W – with multiple- voltage power supply input

N 950.50 KNDC-B with brushless DC motor

flexible •custom-fit•cost

-effec

tive

KNF Modular System

Please visit our website www.knf.com

to get more information

Page 2: N 950.50 SERIES VACUUM PUMPS - KNFAuspumpkurve10-liter-Daten N950.50 KNBC-B; KNE-W Saugvermögen Daten N950.50 KNBC-B; KNE-W 0.1 1 10 100 1000 pressure in mbar 0.01 0.1 1 10 suction

Kurve Daten N950.50 KNBC-B; KNE-W

0 100 200 300 400 500 600 700 800 900 1000pressure in mbar

0

12

24

36

48

60

flow

rate

in l/

min

0 100 200 300 400 500 600 700 800 900 1000

pressure in hPa

29.9 27.0 24.0 21.1 18.1 15.1 12.2 9.2 6.3 3.3 0pressure in inHg

0 2 4 6 8 100

200

400

600

800

atm.

pump down time in min

pres

sure

in m

bar

Auspumpkurve10-liter-Daten N950.50 KNBC-B; KNE-W

Saugvermögen Daten N950.50 KNBC-B; KNE-W

0.1 1 10 100 1000pressure in mbar

0.01

0.1

1

10

suct

ion

spee

d in

m3 /h

1 10 100 1000

pressure in hPa

N 950.50 KNE-W

N 950.50 KNE-W

N 950.50 KNE-W | PUMP DOWN TIME FOR 10 LITER VESSEL N 950.50 KNE-W | SUCTION PUMPING SPEED (1.500 1/MIN)

PERFORMANCE DATASeries model Flow rate at

atm. pressure(l/min)1)

Max. operat-ing pressure (bar rel./psig)

Ultimate vacuum(mbar abs.)

N 950.50 KNE-W 55.0 0.5/7.3 21) Liter at STP

N 950.50 KNE-W

mmin

Page 3: N 950.50 SERIES VACUUM PUMPS - KNFAuspumpkurve10-liter-Daten N950.50 KNBC-B; KNE-W Saugvermögen Daten N950.50 KNBC-B; KNE-W 0.1 1 10 100 1000 pressure in mbar 0.01 0.1 1 10 suction

Kurve Daten N950.50 KNBC-B; KNE-W

0 100 200 300 400 500 600 700 800 900 1000pressure in mbar

0

12

24

36

48

60

flow

rate

in l/

min

0 100 200 300 400 500 600 700 800 900 1000

pressure in hPa

29.9 27.0 24.0 21.1 18.1 15.1 12.2 9.2 6.3 3.3 0pressure in inHg

Saugvermögen Daten N950.50 KNBC-B; KNE-W

0.1 1 10 100 1000pressure in mbar

0.01

0.1

1

10

suct

ion

spee

d in

m3 /h

1 10 100 1000

pressure in hPa

0 2 4 6 8 100

200

400

600

800

atm.

pump down time in min

pres

sure

in m

bar

Auspumpkurve10-liter-Daten N950.50 KNBC-B; KNE-W

N 950.50 KNDC-B

N 950.50 KNDC-B

N 950.50 KNDC-B | PUMP DOWN TIME FOR 10 LITER VESSEL N 950.50 KNDC-B | SUCTION PUMPING SPEED (1.500 1/MIN)

N 950.50 KNDC-B

PERFORMANCE DATASeries model Flow rate at

atm. pressure (l/min)1)

Max. operat-ing pressure (bar rel./psig)

Ultimate vacuum(mbar abs.)

N 950.50 KNDC-B 55.0 0.5/7.3 21) Liter at STP

mmin

Page 4: N 950.50 SERIES VACUUM PUMPS - KNFAuspumpkurve10-liter-Daten N950.50 KNBC-B; KNE-W Saugvermögen Daten N950.50 KNBC-B; KNE-W 0.1 1 10 100 1000 pressure in mbar 0.01 0.1 1 10 suction

ACCESSORIESDescription Illustration Part No. DetailsControl cable 125391 0.5 m long

Gas ballast valve on request

Hose connector 004950 G 1/4, for tube ID 9

Sealing for hose connector 029112 G 1/4

Small flange, stainless steel 048116 G 1/4, KF 16

SPARE PARTSDescription Part No. DetailsSpare parts kit 125411 Diaphragm, valves, sealing ring

www.knf.com

KN

F re

serv

es t

he r

ight

to

mak

e te

chni

cal c

hang

es w

ithou

t no

tice.

KN

F 05

/201

9. w

ww

.knf

.com

The performance values for the series models shown on this data sheet were determined under test conditions. The actual performance values may differ and depend in particular on the usage conditions and therefore on the specific application, on the parameters of the components involved in the user’s system and on any technical modifi- cations carried out which deviate from the standard configuration or the as delivered condition.

If individual designs have been created for specific customers on the basis of series models, other technical performance data may apply. Before operation begins, the relevant operating instructions and/or assembly or installation instructions should be read and the safety information contained in these instructions should be noted. KNF reserves the right to make changes to the product and the associated documen-tation without prior notice to the customer.