n-comfort nexans thermostat programme · nexans’ heating system portfolio. precise and accurate...

4
Nexans Thermostat Programme N-Comfort Nexans Thermostat Programme

Upload: others

Post on 16-Jan-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: N-Comfort Nexans Thermostat Programme · Nexans’ heating system portfolio. Precise and accurate temperature control is important to fully achieve the advan - tages of floor heating

Nexans Thermostat Programme

N-ComfortNexans Thermostat Programme

Page 2: N-Comfort Nexans Thermostat Programme · Nexans’ heating system portfolio. Precise and accurate temperature control is important to fully achieve the advan - tages of floor heating

N-Comfort Thermostat Programme

Nexans thermostat programme

Type CDFR-001 CDFR-002 CEF-001 CR-001

Description Programmable digital thermostat with room and floor sensor and day/night function

Programmable digital thermostat with room and floor sensor and pre-programmed day/night function

Electronic thermostat with room and floor sensor without day/night function

Power regulator

Application For indoor use in all room types

For indoor use in all room types

For indoor use in all room types

For indoor use. Recom-mended in small rooms

Technical dataRated VoltageMax. loadIP ClassTemperature scaleAccuracyMax. circuit breaker sizeLength of floor sensorOn/off-switchRegulating periodTemperature limitationFactory sensor settingOptimising function

230 VAC, 50 Hz3600 W, 16 AIP21+5 to +37 °C0.4 °C16 A3 mTwo-poleN/AYesFloorYes

230 VAC, 50 Hz3600 W, 16 AIP21+5 to +37 °C0.4 °C16 A3 mTwo-poleN/AYesRoomYes

230 VAC, 50 Hz3600 W, 16 AIP21+5 to +37 °C0.4 °C16 A3 mTwo-poleN/AYesFloorNo

230 VAC, 50 Hz3600 W, 16 AIP21N/AN/A16 A3 mTwo-pole30 min.NoN/AN/A

The N-Comfort thermostat programme adds a new and powerful dimension to Nexans’ heating system portfolio.

Precise and accurate temperature control is important to fully achieve the advan-tages of floor heating without using more electric energy than necessary. Heating cables in combination with an accurate thermostat are probably the most energy efficient heating system one can have in a modern building.

The design of the thermostat is unique, and every detail has been carefully designed paying special attention to aesthetic appear ance, user-friendliness and quality, as required and demanded by both consumers and professional installers.

In addition to the thermostats being easy to install and adjust, the temperature is digitally controlled by software specifically developed for underfloor heating systems.The N-Comfort series comprises four different controllers – three thermostats and one power regulator. Whatever your need is, you will find a N-Comfort controller optimal for your needs. From just simple power control to advanced day/night control, N-Comfort will do the job!

Page 3: N-Comfort Nexans Thermostat Programme · Nexans’ heating system portfolio. Precise and accurate temperature control is important to fully achieve the advan - tages of floor heating

N-Comfort CDFR-001 and CDFR-002The N-Comfort CDFR range comprises programmable digital thermostats for use in all indoor room types. The two versions are delivered with different factory set-ups to make installation as quick and easy as possible, but both types can be programmed to fit the users’ needs in any room. The thermo-stats are equipped with both room and floor sensor. It is up to the installer to determine which sensor to activate. If necessary, both sensors can be acti-vated. The floor sensor will then function as a temperature limitation sensor in order to avoid overheating of the floor.

N-Comfort CEF-001The model CEF-001 is an electronic thermostat for use in all indoor room types. It is equipped with both a room and a floor sensor. Which sensor to use can be chosen by simply adjusting a jumper behind the front cover. If the floor sensor is the active sensor, it will also function as a temperature limitation sensor. The maxi-mum allowed floor temperature can be set by adjusting a potentiometer positioned behind the front cover.

The N-Comfort CEF-001 is recommended for use in all room types. It is especially suitable for bathrooms and other rooms with concrete floors and high output (100 – 150 W/m²).

N-Comfort CR-001CR-001 is a power regulator with no sensor. By turning the wheel, the user can control the heating cable’s output. The regulator works with a cycle of 30 minutes. Turning the wheel tells the regulator how many minutes it shall stay on and off within the cycle.

Example: The regulator wheel is put in position ”5”, pointing straight upwards. The regulator will turn the cables on for 15 minutes and off for 15 minutes, working in 30 minute cycles. The resulting heating cable output is 50% of the nominal wattage.

The N-Comfort CR-001 is recommended for use in small rooms with concrete floors like for example toilets, small bathrooms etc. It is also ideal for replacing old 1-2-3-switches commonly used in the 70’s and 80’s.

Model CDFR-001 CDFR-002

Default sensor Floor Room

Factory programming No factory set day/night programme

Day/night function for weekdays and weekends can be programmed by the user

4-event programmeWeekdays, mon – fri:1. 2.3.4.2-event programme Weekend:1.2.

Recommended room types • Bathroom• Washroom• Toilet• Concretefloorswithhigh

output in general

• Livingroom• Kitchen• Sleepingroom• Hall• Livingareasingeneral

Factory settings:

CDFR-001 and CDFR-002

CR-001 and CEF-001

Page 4: N-Comfort Nexans Thermostat Programme · Nexans’ heating system portfolio. Precise and accurate temperature control is important to fully achieve the advan - tages of floor heating

Installation of floor sensorApplicable for: CDFR-001, CDFR-002,

CEF-001Parts needed: Sensor (enclosed in

thermostat package) Flexible conduit, same

length as the sensor Piece of tape, approx.

10 cm.

Seal off the flexible conduit in the floor end with a piece of tape, and install it in the floor, centered between two heating cable strings. It should reach at least 50 cm into the floor. The other end of the conduit shall end up in the junction box where the thermostat shall be installed. Then feed the sensor into the conduit from the junction box end so that the end of the sensor ends up near the floor end of the conduit.

Installation of the thermostatApplicable for: All modelsParts needed: Thermostat or regulator Junction box Mounting screws to

fasten the thermostat/regulator

Make sure that the power supply is completely disconnected. Open the thermostat by using a small screwdriver and remove the frame and the front cover. Connect the heating cable, power leads and sensor (if applicable) to the correct terminals on the back side of the thermostat/regulator. Put the thermostat/regulator in place in the junction box and attach it with mounting screws. Put the frame and front cover in place and attach by applying a light pressure until a ”click” is heard.

Full installation instructions are enclosed in the box.

Nexans Norway AS, Innspurten 9, Helsfyr, P.O.Box 6450 Etterstad, N-0605 Oslo, Norway Phone: + 47 22 88 61 00, Fax: + 47 22 88 61 01, [email protected]

www.nexans.no, www.nexans.com/heating

NEXANS NORWAY AS reserves the right to implement product changes without prior notice, as our products are being continuously developed.

Global expert in cables and cabling system

Save money with day/night temeperature controlUsing the day/night function in CDFR-001 and CDFR-002 is likely to have a very positive impact on heating expenses. It is recommended to use this functionality in all living areas like living rooms, sleeping rooms, kitchens and halls. The electricity consumption has been proven to be reduced by up to 25% compared to buildings with no such temperature control. Modern heating cable solutions are thin with less mass to be heated. This makes modern heated floors very suitable for day/night temperature control.

Positioning of the floor sensor

Installation and use of the thermostat

Lude

ns R

ekla

meb

yrå

/ 25

Mar

ch 2

008

/ 30