Prod. No. Name Description Analogue Inputs IP Class
DCP1 25001 Display Control 1 2 lines text display, numeric keys and alarm indication 1 x product pressure, 1 x oxygen readings IP 54
IPC 25010 Intellicontrol Touch screen 7 colour, wide screen, alarm indication and trends 1 x product pressure, 1 x oxygen readings, 2 x column pressure IP 54
* All volumetric units: [Sm] 15 gr. 981 mbar ** Modification possible Note: Capacity of the plant is stated at 30C ambient air temperature. Variance5%
WORLDWIDE MANUFACTURER OF PSA GENERATORS
OXYMAT NITROGEN GENERATORS
Maximum operating pressure 8 bar (g)
Operating temperature 10-40C
Minimum inlet pressure 7 bar (g)
Dew point max +3C
Air quality ISO Specification ISO 8573.1:2001.2.4.1
model Nitromat N040 ECO
Nitrogen purity rate [%, ppm] 5% 95 3% 97
2% 98
1% 99
0,5% 99.5
0.1% 99.9
500ppm 99.95
100ppm 99.99
50ppm 99.995%
10ppm 99.999%
5ppm 99.9995
1ppm 99.9999
Sm/hour (*) 5.00 4.00 3.50 3.00 2.49 1.67 1.38 0.78 0.62 0.44 0.39 0.27
Air feed [m/min.] F.A.D. at min. 7 bar 0.17 0.15 0.14 0.14 0.12 0.09 0.08 0.06 0.06 0.05 0.04 0.04
Power consumption generator [kW]
Nitrogen outlet pressure [bar] (g) (**) 5
Minimum Nitrogen receiver tank [litres] 20
Minimum Air receiver tank [litres] 20
Hose connection [inches] 3/4
Dimensions L x W x H [cm] 50x60x150
Shipping dimensions L x W x H [cm] 70x80x175
Maintenance area L x W x H [cm] 70x130x170
Weight [kg] 115
0.1
20 20 20 20 20 20 20 20 20 20 20
20 20 20 20 20 20 20 20 10 10 10