 COMPRESSED AIR CONTROL PANELS FOR STANDARD SOLUTIONS ISO 9001 ISO 13485 PED 97/23/EC MDD 93/42/EC Prod. No. Name Description Analogue Inputs IP Class DCP1 25001 Display Control 1 2 lines text display, numeric keys and alarm indication 1 x product pressure, 1 x oxygen readings IP 54 IPC 25010 Intellicontrol Touch screen 7” colour, wide screen, alarm indication and trends 1 x product pressure, 1 x oxygen readings, 2 x column pressure IP 54 * All volumetric units: [Sm³] 15 gr. 981 mbar ** Modification possible Note: Capacity of the plant is stated at 30 C ambient air temperature. Variance±5% WORLDWIDE MANUFACTURER OF PSA GENERATORS OXYMAT NITROGEN GENERATORS Maximum operating pressure 8 bar (g) Operating temperatur e 10-40°C Minimum inlet pressure 7 bar (g) Dew point max +3°C Air quality ISO Specificatio n ISO 8573.1:2001.2.4.1 model Nitromat N040 ECO Nitrogen p urity rate [%, ppm] 5% 95 3% 97 2% 98 1% 99 0,5% 99.5 0.1% 99.9 500ppm 99.95 100ppm 99.99 50ppm 99.995% 10ppm 99.999% 5ppm 99.9995 1ppm 99.9999 Sm³/hour (*) 5.00 4.00 3.50 3.00 2.49 1.67 1.38 0.78 0.62 0.44 0.39 0.27 Air feed [m³/min.] F.A.D. at min. 7 bar 0.17 0.15 0.14 0.14 0.12 0.09 0.08 0.06 0.06 0.05 0.04 0.04 Power consumption generator [kW] Nitrogen outlet pressure [bar] (g) (**) 5 Minimum Nitrogen receiver tank [litres] 20 Minimum Air receiver tank [litres] 20 Hose connection [inches] 3/4 Dimensions L x W x H [cm] 50x60x150 Shipping dimensions L x W x H [cm] 70x80x175 Maintenance area L x W x H [cm] 70x130x170 Weight [kg] 115 0.1 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 10 10

Upload: ddadara

Post on 06-Oct-2015

8 views

Category:

Documents


0 download

DESCRIPTION

OXYMAT

TRANSCRIPT

  • COMPRESSED AIR

    CONTROL PANELS FOR STANDARD SOLUTIONS

    ISO 9001 ISO 13485

    PED 97/23/EC MDD 93/42/EC

    Prod. No. Name Description Analogue Inputs IP Class

    DCP1 25001 Display Control 1 2 lines text display, numeric keys and alarm indication 1 x product pressure, 1 x oxygen readings IP 54

    IPC 25010 Intellicontrol Touch screen 7 colour, wide screen, alarm indication and trends 1 x product pressure, 1 x oxygen readings, 2 x column pressure IP 54

    * All volumetric units: [Sm] 15 gr. 981 mbar ** Modification possible Note: Capacity of the plant is stated at 30C ambient air temperature. Variance5%

    WORLDWIDE MANUFACTURER OF PSA GENERATORS

    OXYMAT NITROGEN GENERATORS

    Maximum operating pressure 8 bar (g)

    Operating temperature 10-40C

    Minimum inlet pressure 7 bar (g)

    Dew point max +3C

    Air quality ISO Specification ISO 8573.1:2001.2.4.1

    model Nitromat N040 ECO

    Nitrogen purity rate [%, ppm] 5% 95 3% 97

    2% 98

    1% 99

    0,5% 99.5

    0.1% 99.9

    500ppm 99.95

    100ppm 99.99

    50ppm 99.995%

    10ppm 99.999%

    5ppm 99.9995

    1ppm 99.9999

    Sm/hour (*) 5.00 4.00 3.50 3.00 2.49 1.67 1.38 0.78 0.62 0.44 0.39 0.27

    Air feed [m/min.] F.A.D. at min. 7 bar 0.17 0.15 0.14 0.14 0.12 0.09 0.08 0.06 0.06 0.05 0.04 0.04

    Power consumption generator [kW]

    Nitrogen outlet pressure [bar] (g) (**) 5

    Minimum Nitrogen receiver tank [litres] 20

    Minimum Air receiver tank [litres] 20

    Hose connection [inches] 3/4

    Dimensions L x W x H [cm] 50x60x150

    Shipping dimensions L x W x H [cm] 70x80x175

    Maintenance area L x W x H [cm] 70x130x170

    Weight [kg] 115

    0.1

    20 20 20 20 20 20 20 20 20 20 20

    20 20 20 20 20 20 20 20 10 10 10