nc - mechanical float level switchesall level switches use a hermetically sealed reed contact...

10
NC - Mechanical Float Level Switches Special Features: z Available Materials: Brass, Stainless Steel, Buna-N, Polypropylene and PVC z Maximum Pressure: 400 PSIG z Maximum Temperature: 300°F z Singlepoint and Multipoint Designs z Field Changeable Switch Logic Versatile Design Our level switch products are designed to meet a wide range of application requirements by addressing such design considerations as: z Pressure and Temperature z Mounting Orientation z Termination z Media Characteristics such as Density, Viscosity and Corrosivity z Materials of Construction z Switch Load Design Flexibility Some level switches can be provided to detect the interface between two dissimilar liquids such as water and oil. Our level switches can be provided with other mounting styles such as flanges, bent stem, different NPT, straight threads, and metric size mounting plugs. Our level switches can be made intrinsically safe for hazardous applications by the use of I.S. barriers such as the REL-6000 series. Contact protection relays such as the RL-series should always be considered to protect switches from overload. Operation All level switches use a hermetically sealed reed contact actuated by a magnet in the float. As the float rises and falls, the magnetic field causes the switch inside the stem to open or close. Our level switches can be mounted in the tank top or bottom, or can be adapted for side mounting. Switches will operate normally with up to a 30 degree tilt from vertical. All single point switches are field selectable for normally open (N/O) or normally closed (N/C) switch operation by simply removing the retaining ring and flipping the float. Copyright 2008 Flow Network http://www.flow-network.com Acworth, GA 30101 Phone (770) 917-0940 Fax (770) 917-8352 Email [email protected] Page 1/10

Upload: others

Post on 23-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NC - Mechanical Float Level SwitchesAll level switches use a hermetically sealed reed contact actuated by a magnet in the float. As the float rises and falls, the magnetic field causes

NC - Mechanical Float Level Switches

Special Features:

Available Materials: Brass, Stainless Steel, Buna-N, Polypropylene and PVC Maximum Pressure: 400 PSIG Maximum Temperature: 300°F Singlepoint and Multipoint Designs Field Changeable Switch Logic

Versatile Design

Our level switch products are designed to meet a wide range of application requirements by addressing such design considerations as:

Pressure and Temperature Mounting Orientation Termination Media Characteristics such as Density, Viscosity and Corrosivity Materials of Construction Switch Load

Design Flexibility

Some level switches can be provided to detect the interface between two dissimilar liquids such as water and oil. Our level switches can be provided with other mounting styles such as flanges, bent stem, different NPT, straight threads, and metric size mounting plugs.

Our level switches can be made intrinsically safe for hazardous applications by the use of I.S. barriers such as the REL-6000 series. Contact protection relays such as the RL-series should always be considered to protect switches from overload.

Operation

All level switches use a hermetically sealed reed contact actuated by a magnet in the float. As the float rises and falls, the magnetic field causes the switch inside the stem to open or close. Our level switches can be mounted in the tank top or bottom, or can be adapted for side mounting. Switches will operate normally with up to a 30 degree tilt from vertical.

All single point switches are field selectable for normally open (N/O) or normally closed (N/C) switch operation by simply removing the retaining ring and flipping the float.

Copyright 2008 Flow Network http://www.flow-network.comAcworth, GA 30101 Phone (770) 917-0940 Fax (770) 917-8352 Email [email protected]

Page 1/10

Page 2: NC - Mechanical Float Level SwitchesAll level switches use a hermetically sealed reed contact actuated by a magnet in the float. As the float rises and falls, the magnetic field causes

NC - Mechanical Float Level Switches

NCP Small Polypropylene Switches

Copyright 2008 Flow Network http://www.flow-network.comAcworth, GA 30101 Phone (770) 917-0940 Fax (770) 917-8352 Email [email protected]

Page 2/10

Page 3: NC - Mechanical Float Level SwitchesAll level switches use a hermetically sealed reed contact actuated by a magnet in the float. As the float rises and falls, the magnetic field causes

NCP Small Polypropylene Switches

NCB Small BUNA-N Switches

Copyright 2008 Flow Network http://www.flow-network.comAcworth, GA 30101 Phone (770) 917-0940 Fax (770) 917-8352 Email [email protected]

Page 3/10

Page 4: NC - Mechanical Float Level SwitchesAll level switches use a hermetically sealed reed contact actuated by a magnet in the float. As the float rises and falls, the magnetic field causes

NCB General Purpose BUNA-N Switches

Copyright 2008 Flow Network http://www.flow-network.comAcworth, GA 30101 Phone (770) 917-0940 Fax (770) 917-8352 Email [email protected]

Page 4/10

Page 5: NC - Mechanical Float Level SwitchesAll level switches use a hermetically sealed reed contact actuated by a magnet in the float. As the float rises and falls, the magnetic field causes

NCS All Stainless Steel Switches

Copyright 2008 Flow Network http://www.flow-network.comAcworth, GA 30101 Phone (770) 917-0940 Fax (770) 917-8352 Email [email protected]

Page 5/10

Page 6: NC - Mechanical Float Level SwitchesAll level switches use a hermetically sealed reed contact actuated by a magnet in the float. As the float rises and falls, the magnetic field causes

NC Bent Stem Sidemount And Pvc Switches

Copyright 2008 Flow Network http://www.flow-network.comAcworth, GA 30101 Phone (770) 917-0940 Fax (770) 917-8352 Email [email protected]

Page 6/10

Page 7: NC - Mechanical Float Level SwitchesAll level switches use a hermetically sealed reed contact actuated by a magnet in the float. As the float rises and falls, the magnetic field causes

NCG Standard Multipoint Level Switches

Copyright 2008 Flow Network http://www.flow-network.comAcworth, GA 30101 Phone (770) 917-0940 Fax (770) 917-8352 Email [email protected]

Page 7/10

Page 8: NC - Mechanical Float Level SwitchesAll level switches use a hermetically sealed reed contact actuated by a magnet in the float. As the float rises and falls, the magnetic field causes

NCG Standard Multipoint Level Switches

Copyright 2008 Flow Network http://www.flow-network.comAcworth, GA 30101 Phone (770) 917-0940 Fax (770) 917-8352 Email [email protected]

Page 8/10

Page 9: NC - Mechanical Float Level SwitchesAll level switches use a hermetically sealed reed contact actuated by a magnet in the float. As the float rises and falls, the magnetic field causes

NCM Miniature Multipoint Level Switches

Copyright 2008 Flow Network http://www.flow-network.comAcworth, GA 30101 Phone (770) 917-0940 Fax (770) 917-8352 Email [email protected]

Page 9/10

Page 10: NC - Mechanical Float Level SwitchesAll level switches use a hermetically sealed reed contact actuated by a magnet in the float. As the float rises and falls, the magnetic field causes

NCM Miniature Multipoint Level Switches

Copyright 2008 Flow Network http://www.flow-network.comAcworth, GA 30101 Phone (770) 917-0940 Fax (770) 917-8352 Email [email protected]