ncr 35298

1

Click here to load reader

Upload: cblair

Post on 04-Mar-2016

214 views

Category:

Documents


0 download

DESCRIPTION

Nonconformance Report

TRANSCRIPT

Page 1: Ncr 35298

7/21/2019 Ncr 35298

http://slidepdf.com/reader/full/ncr-35298 1/1

NCR Record

NCR 35298 Status Submit To Source (290)

Initiator  KIRCHEIS, BRYCE Entry User CMA7551

Initiator Location Warranty Services Entry Date 10/02/2014

Project USUCBWRT-UA32 - UF WARRANTY Supervisor  MCCOLL, ANTHONY

Qty 3 Date of Nonco n 07/10/2014

BOM Item / WBSCode TAL-S326636 Supplier  EXLAR CORPORATION

P.O.# Prod. Order  

NCR Error Code DAMAGED/FAULTY PART Part Descr EXLAR ACTUATOR (LINEAR)-VERSA GUN SERVOCOMAU/ABB/KUKA

Rework Hrs 0 Print / BOM Revision Mfg. Part Number: VG GSX40-0602

Material Costs 7,845.00 Unit 2014-00001544

Total NCR Costs 0

 Ac tio n Due Date 10/23/2014 Source of Noncon Supplier Quality Issue-Arlans Blair, Chris

 Ass ign ee

4M Analysis Man: Machine: Method: Y Material: Y

Detailed ProblemDescription

The results from the training cell evaluation where clear, however the root-cause HASN¿T been identified yet (and this makes the results veryconfusing) Mfg. Name: EXLAR CORPORATION Description: ACTUATOR (LINEAR)-VERSA GUN SERVO COMAU/ABB/KUKA Mfg. PartNumber: VG GSX40-0602 TAL-S326636 (2) GSX40-0602 servo actuator TAL-S326637 (1) GSX40-0605 servo actuator

Comment

The facts are straight forward: 1. The fault / error code identified a ¿grounding¿ issue to axis 8 (servo weld gun) 2. The fault / error codes at therobot were eliminated only when the actuator was replaced. 3. The fault / error codes haven¿t reappeared since the actuator was replaced. 4.The actuators passed the ¿hi-pot test¿ at 2800V 5. The actuators operated perfectly when connected to a series of ¿closed-loop test¿, using asimple drive unit (powered at 120V) 6. The ¿05¿ actuator that had the ¿hard fault¿ on Sunday, operated without error when connected to thetraining robot (not connected to gun) The next step are: A. Tomorrow (July 2nd) the ¿05¿ hard-fault actuator will be tested on the robot in ARS

S12R02, to see if we can replicate the fault / error (to protect production, the unit will be operated off of the gun). B. Bryce Kircheis will provide: a.(2) GSX40-0602 Comau actuators + (1) GSX40-0605 Comau actuator to John Saari, in warranty exchange for the 3 units that have causedproblems. b. *the recovered units will be returned to the Innovation Center, where they can be tested on the Blue Room robots i. Doug / Tony willmake sure we have the same condition of robot in the test to replicate the fault / error code C. Chris Somercik will provide a quote to John Saarifor a simple Lenze test amplifier, so that John can operate the servo guns off of the robot to help in future investigations. During our investigation,Dave Taylor visited the training cell¿he isn¿t very happy with the problems he is having with the Comau equipment, and he doesn¿t want anymore lost production due to Comau! There will be a report from Chris Somercik and Doug Holland, that will address the testing and results. Istrongly recommend an internal Comau Kaizen to see if we can determine the root-cause of this problem.

Design House

Interim Corrective Ac tio n Requested

Repair by Floor Other

Problem Statement

Interim Corrective Ac tion

Root Cause

PermanentCorrective Action

Error Code

Drawing Path

Gatekeeper  BLAIR, CHRIS Concurrence No Closure No

Rework Hours Em pl oy ee L oc at io n Dat e Tas k Ho ur s

 A  A  A

Page 1 of 1 NCR System

12/2/2015http://uussth01wbxp010/wbs/NC004.NcrForm?p_ncrid=35298&p_action=search