ndt method and acceptance criteria.docx
TRANSCRIPT
-
8/11/2019 NDT Method and Acceptance Criteria.docx
1/1
NDT METHOD TESTING METHOD ACCEPTANCE
STRUCTURAL: Non Tubular
VTAWS D1.1/D1.1 M:2002 Part 6.9 Visual
Inspection
AWS D1.1 / D1.1 M:2002,Structural Welding Code Steel,
Section 6 Table 6.1
PT
ASTM E 16595
Standard Test Method for LiquidPenetrant Examination
MTASTM E70991
Standard Practice for Magnetic Particle
UT
ASTM E 16497Standard Practice for Ultrasonic Contact
Examination of weldments
AWS D1.1 M:2002Standard welding code-steel Section 6,
Table 6.2 UT AcceptanceRejectionCriteria (Statically loaded non-tubular
connections)
RT
ASME V, Article 2, RadiographicExamination with reference to ASTM
1032-92
AWS D1.1 / M:2002 Paragraph 6.12.1 Non Destructive TestingRadiographic
Testing Acceptance Criteria for Non-
Tubular connections
STRUCTURAL: Tubular
PT
ASTM E16599Standard Test Method for Liquid
Penetrant Examination
MT Same of non-tubular
UT
ASTM E16497Standard Practice for Ultrasonic Contact
Examination of Weldments
AWS C6.13.3Ultrasonic Acceptance Criteria for
Tubular Connections
RT
ASME V, Article 2,
Radiographic Examination withreference to ASTM 1013292
AWS D1.1 M:2002 Paragraph 6.12.3Non Destructive Testing Radiographic
Testing Acceptance Criteria for TubularConnections
PRESSURE VESSELS
PT ASTM E6595Standard Test Method for Liquid
Penetrant Examination
MT ASME V Article 25Magnetic Particle Standards Paragraph
4.2
UT ASTM E16497Standard Practice for Ultrasonic Contact
Examination of weldments
ASME VIII Div. 1,Appendix 12 Paragraph 3,
Acceptance Rejection Standards
RT ASME Section V, Article 2,Radiographic Examination
ASME 1, Part PR51,Acceptance Standards for Radiography
POWER BOILER
PT
MT
UT ASTM E16492,Standard Practice for Ultrasonic Contact
Examination of weldments
ASME VIII Div. 1, Appendix 12Paragraph 3,
Acceptance Rejection Standard
RT ASME Section V, Article 2,Radiographic Examination
ASME I, Part PR51 , Acceptance Standards for Radiography