TRANSCRIPT
NEC Varnasep 12-18, 2005
A. Marinov
Andrey Marinov On behalf of the CMS Forward RPC Collaboration
Y. Ban, J. Cai, H. Liu, S. Qian, Q. Wang, Y. Ye, J. Ying, Yucheng Ge - Peking University, Beijing, China
B. Hong , S. J. Hong , K. S. Lee, S. Park, K. S. Sim - KODEL, Seoul, S. KoreaA. Ball, J-P. Chatelain, I. Crotty, A. Sharma, W. Whitaker - CERN, Geneva, Switzerland
W. Van Doninck - Vrije Universiteit Brussel, Brussels, BelgiumS. Akimenko - IHEP, Protvino, Russia
L. Litov, A. Marinov - University of Sofia, Sofia, BulgariaA. Devlieger – University of Victoria, Victoria, Canada
M. I. Asghar, I. Ahmed, H. Hoorani - National Centre for Physics, Quaid-i-Azam University Campus, Islamabad, Pakistan
Z. Aftab, M. S. Khan, T. Solaija - Pakistan AtomicEnergy Commission, Islamabad, PakistanA. Colaleo, G. Iaselli, F. Loddo, M. Maggi - INFN Bari, Itlay
B. Michal Marcisovsky Samuel Scheonholz Rene Kuo Manohar Jonnalagedda CERN Geneva
2NEC Varnasep 12-18, 2005
A. Marinov
CMS Detector
Endcaps
3NEC Varnasep 12-18, 2005
A. Marinov
FORWARD Resistive Plate Chambers
Final Gas mixture used in all tests95.5 Freon 3.5 Isob 0.3 SF6 + RH 50% = 5000 ppm
4NEC Varnasep 12-18, 2005
A. Marinov
Forward RE Resistive Plate Chambers
• 96 Channels. 3 sectors by 32 strips A ,B, C
• Standard LVDS output
• Slow Control for Threshold and temperature measurements for each F.E.B.
5NEC Varnasep 12-18, 2005
A. Marinov
Testing RE with Cosmics
• Cosmic stand.Top and Bottom layers
scintilators.
Possibility to put 10 chambers inside to test them with cosmics
6NEC Varnasep 12-18, 2005
A. Marinov
Cosmic Stand Trigger
Counters Setup
7NEC Varnasep 12-18, 2005
A. Marinov
Cosmic Stand TriggerElectronics Setup
8NEC Varnasep 12-18, 2005
A. Marinov
Cosmic Stand Data Acquisition
Run Signal
Recording
EnableTrigger
RecordingStop recording
Reading the TDCs
9NEC Varnasep 12-18, 2005
A. Marinov
Main VME Frame
10NEC Varnasep 12-18, 2005
A. Marinov
Data Format From the TDC
64 bit channel information1 time bin is 10ns
1 1 1
128 bit presenting the time information from each TDC
64 bit channel information
64 bit channel information
0 0 0 0… …
11NEC Varnasep 12-18, 2005
A. Marinov
Software and Computing
DAQ PC Database PC
MXI bus
TCP/IP
TCP/IP
Tracking PC
CAEN 1527HV power supply
TCP/IP
I2C MultiplexerFor slow control
RS232
Control PC
12NEC Varnasep 12-18, 2005
A. Marinov
Software and ComputingDAQ PC
MXI bus
Pentium 4 1.6 GHz512Mb RAM120GB HDD
Linux PlatformUsing standard drivers from National Instruments for the MXI/PCI controller.
Running Software Offline Analyses Software
Online Tracking engine
13NEC Varnasep 12-18, 2005
A. Marinov
Data From Cosmic TestStrips Profile
Using only 2 scintilators from the top and 2 form the bottom layer
14NEC Varnasep 12-18, 2005
A. Marinov
Data From Cosmic TestStrips Profile
Coincidence with 2 scintilators from top, 2 from bottom and small counter placed on sector B.
15NEC Varnasep 12-18, 2005
A. Marinov
Data From Cosmic Test
triggers
noisenoiserate N
NN
stripratestrips
noiserate NN
/32
Noise and Time distribution
Time bins 0-128 (1bin is 10ns)
Counts400ns
60ns
Noise
Noise
]/[]/[
]/[
22
2
1
1.
1.
cmHzcmHz
runstripsnoisecmHz
R
TSNR
16NEC Varnasep 12-18, 2005
A. Marinov
Data From Cosmic TestTime Distribution
17NEC Varnasep 12-18, 2005
A. Marinov
Data From Cosmic StandEfficiency and Cluster Size
Scanning for efficiency and Cluster size values at different voltages.
18NEC Varnasep 12-18, 2005
A. Marinov
Online Tracking Software
19NEC Varnasep 12-18, 2005
A. Marinov
Continuously H.V. MonitoringRecording the HV currents every 2 min, and store the data in to the Database.
Including the environment conditions. Temperature and Humidity
20NEC Varnasep 12-18, 2005
A. Marinov
Databasehttp://forwardrpc.cern.ch/cms_forward_rpc/index.htm
Online • HV monitoring and QC IV
data storage• Searchable tracking for
individual Gaps / Chambers
• Production QC procedures • Mechanics• Cosmic Tests
VISIBLESEARCHABLEWORLDWIDE
Chamber QC data Gas gaps QC data
Environment conditions data
DATABASE
Production data
Results form Cosmic Test
21NEC Varnasep 12-18, 2005
A. Marinov
Quality Control and Certification for CMS installation
• Checklists are included in all production steps• Quality control and measurements for the gaps• Cosmic Test Data for Noise, Strips Profile, Efficiency, Cluster Size, HV monitoring, Environment conditions.
Certification file for each Endcap RPC Detector
22NEC Varnasep 12-18, 2005
A. Marinov
Summary and Future
Summary•All tests and QC for RE chambers are set up.•100 chambers (RE) are Quality Certificated and ready for Installation in CMS experiment•Production and QC processes are in time.
To do•Optimizing the tracking software