netastra product family overview. netastra solution highlights high capacity per sector 200 mbps...
TRANSCRIPT
NetAstra NetAstra Product Family Overview Product Family Overview
NetAstra Solution Highlights
High capacity per Sector• 200 Mbps aggregate throughput
Ethernet connectivity Low cost 50 Mbps Base Station High capacity end user equipment –5, 10, 20, 50 Mbps Up to 32 SUs per sector Guaranteed SLA and capacity per Subscriber Unit Small and constant latency- 4 to 10msec typical under full sector load Wide range of frequency bands - 4.9 to 6 GHz, 3.3-3.8 GHz, 205
GHz
High capacity PtMP for bandwidth demanding applications and guaranteed SLA
Common Architectures
3
IP/MPLS
Enterprise Network
Network
1Network
1
Enterprise Networks:ETH / TDM / FR / ATM
• Access Backhaul• Mobile Backhaul• Video Surveillance• Homeland Security
Enterprise Network
L2VPN/L3VPN
Pseudowires
Network
2Network
2
Network
3Network
3
Enterprise Networks:ETH / TDM / FR / ATM
NetAstra HPMP Link Components
4
High Capacity Base Station:
»NetAstra AU 5x200» NetAstra AU 5x50 » NetAstra AMU 5x100
High Capacity Subscriber Units:
» NetAstra SU 5x05» NetAstra SU 5x50» NetAstra SU 5x20» NetAstra SU 5x10» NetAstra HMU 5x100
Base Station External Antenna
IDU-ODU:CAT-5e ETH Cable
Link Components
5
High Capacity Base Station:
» AU 5x200 – up to 200 Mbps Aggregate» AUM 5x100 – up to 100 Mbps Aggregate» AU 5x50 – up to 50 Mbps Aggregate
High Capacity Subscriber Units:»SU 5x50 – up to 50 Mbps Aggregate»SU 5x20 – up to 20 Mbps Aggregate»SU 5x10 – up to 10 Mbps Aggregate»SU 5x05 – up to 5 Mbps Aggregate
Base Station External Antenna (Dual Polarization) 60°, 90°, 120°
IDU-ODU:CAT-5e ETH Cable
IDU or PoE(AC/DC)
Embedded Antenna
Integrated Antenna
Connectorized Antenna
+
NetAstra AU-5x200 High Capacity Base Station
Fully outdoor
Small form factor ODU
Low Power consumption
High TX power for long range
MIMO/Diversity
NetAstra SU 5xxx - High Capacity Subscriber Unit
Small Form Factor Antenna.ODU is connectorized
High Gain Integrated Antenna
Connectorized ODU
NetAstra HPMP Products – Fixed / Nomadic Radios
8
Product Max. Throughput Antenna Type
NetAstra AU 5x200 200M Aggregate Connectorized - 60°, 90°, 120°
NetAstra AU 5x50 50M Aggregate Connectorized - 60°, 90°, 120°
» NetAstra SU 5x50 50M Aggregate Connectorized / Integrated
» NetAstra SU 5x20 20M Aggregate Embedded / Integrated
» NetAstra SU 5x10 10M Aggregate Connectorized / Embedded
» NetAstra SU 5x05 5M Aggregate Connectorized / Integrated
4.9 GHz, 5.x GHz, 6.x GHz Products
Product Max. Throughput Antenna Type
NetAstra AU 3x100 100M Aggregate Connectorized - 90° (3.x), 60° (2.5)
» NetAstra SU 3x20 20M Aggregate Connectorized / Integrated
» NetAstra SU 3x10 10M Aggregate Connectorized / Integrated
3.x GHz Products
NetAstra HPMP Products – Fixed / Nomadic Radios
9
Product Max. Throughput Antenna Type
NetAstra AU 2x100 100M Aggregate Connectorized - 90° (3.x), 60° (2.5)
» NetAstra SU 2x20 20M Aggregate Connectorized / Integrated
2.5 GHz Products
NetAstra HPMP Unlicensed 5.x Products
Application Product Max. Throughput
Antenna Type
Mobility / Nomadic / FixedNetAstra AUM 5x200 100M Aggregate Connectorized
Nomadic / FixedNetAstra AU 5x200 200M Aggregate Connectorized
Nomadic / FixedNetAstra AU 5x50 50M Aggregate
Connectorized /Integrated
Mobility / Nomadic / FixedNetAstra AUM 5x100 100M Aggregate Connectorized
Nomadic / FixedNetAstra SU 5x50 50M Aggregate
Connectorized / Integrated
Nomadic / FixedNetAstra SU 5x20 20M Aggregate
Embedded /Integrated
Nomadic / FixedNetAstra SU 5x10 10M Aggregate Embedded
Nomadic / Fixed (AC+PoE)
NetAstra SU 5x10 AC 10M Aggregate Integrated
Nomadic / FixedNetAstra SU 5x05 5M Aggregate
Connectorized / Integrated
NetAstra HPMP Licensed 3.x Products
Application Product Max. Throughput Antenna Type
Mobility / Nomadic / FixedNetAstra AU 3x100
100M Aggregate Connectorized
Nomadic / FixedNetAstra SU 3x20
20M Aggregate Connectorized / Integrated
Nomadic / FixedNetAstra SU 3x10
10M Aggregate Connectorized / Integrated
NetAstra HPMP Licensed 2.5 Products
Application Product Max. Throughput Antenna Type
Mobility / Nomadic / FixedNetAstra AU 2x100
100M Aggregate Connectorized
Nomadic / FixedNetAstra SU 2x20
20M Aggregate Connectorized / Integrated
NetAstra Point-to-MultiPoint Portfolio
Highest capacity Base Station
Up to 200 Mbps throughput
Up to 50 Mbps per SU!
Guaranteed SLA (similar to PtP)
Low and fixed Latency
Highest spectrum efficiency – 5 bps/Hz
Long range (40Km)
Carrier grade PtMP
Multi Band: 2.5-2.7 GHz 3.3-3.8 GHz and 4.9-6.0 GHz
Inter / Intra site synchronization
13
Link Components: New AU 5x50 5.x GHz Integrated Antenna
Support up to 50 Mbps net aggregate throughput Comply with ETSI, WPC, MII and Universal regulations
FCC/IC - August/12 Operated with PoE devices (IDU GBE AC and DC) and
IDU DT6 Integrated antenna basic spec:• Gain: 13 dBi• Az. Beam-width: 90 deg.• Frequency: 4.9-5.950 GHz Works with all NetAstra Subscriber Units (SU 5x50, SU
5x20, SU 5x10 and SU 5x05) Support 5 and 10 MHz Channel BW -8 to 25 dBm Support GbE interface
14
Link Components: New SU 5x05 5.x GHz
Support up to 5 Mbps net aggregate throughput Form factors: Connectorized & Integrated Antenna Comply with WPC, MII, Universal, ETSI (May/2012),
FCC/IC (Aug/2012) regulations Operated with PoE devices (IDU GBE AC and DC) Works with all NetAstra Base-stations (AU 5x200 and
AU 5x50) Support 5, 10, 20 and 40 MHz Channel BW -8 to 25 dBm Power consumption < 12 Watt Integrated antenna basic spec:
• Gain: 15 dBi• Az. Beam-width: 15 degrees• El. Beam-width: 30 degrees
Integrated NetAstra SU 5x05
Connectorized NetAstra SU 5x05 D
15
Link Components: IDU – DT6
1U small form factor Indoor unit for ODUs traffic aggregation• 6 POEs for ODUs• Network interfaces – SFP , GE• Built-in switch
Applicable for both NetStream and NetAstra
Customer advantages• Easy installation• Less indoor space• Network interface flexibly
Target market: • ISP/ESP with multiple NetAstra Sectors looking for carrier grade solution • Carrier/ vertical sites with co located NetStream
16
NetAstra HPMP Link Components: IDU DT6
17
The IDU DT6 provides aggregation for multiple NetAstra links and HBSs at a hub locationIt supports all NetStream and NetAstra ODUs
• Up to 6 PoE Interfaces (PoE legacy mode / PoE)
• Up to 25 W per PoE port
•2 LAN Interfaces 10/100/1000 Mbps; auto-negotiation
• SFP Interfaces: 2 x SFP ports of 1000 Mbps (standard MSA)
• 19” rack mounted, 1iU and half width
• Power feeding is 44 VDC - 56VDC, Dual redundant inputs
NetAstra HPMP Link Components: HSU AC + PoE
18
AC in
LAN
DataEMS
AC in
LAN
DataEMS
DC out
DC + Data
PoE Out to feed external device (i.e. Camera)
PoE Out to feed a repeater radio
The NetAstra SU 5x10 AC has a new PoE Out port:The port delivers DC / DC + ETH (user configurable) as seen below:
NetAstra HPMP Link Components: PoE
19
ISP
AC/DC
PoE
Data InCAT-5e ETH Cable
Data Out + DCCAT-5e ETH Cable
NetAstra HPMP Products for Licensed Market
20
The 3.X GHz market
• Mainly dedicated for BWA (especially
3.3, 3.4-3.6 GHz)
• Used by Wi-MAX – 802.16e (TDD) and
Wi-MAX – 802.16d (FDD) technologies
The 2.5 GHz Market
• 2.5 to 2.7 GHz defined for Mobile /
Access applications
• Mobile Wi-MAX (802.16e) -
Residential Access/Mobility
• LTE – Mobility, very few networks
NetAstra Products: 3.3- 3.8 GHz, 2.5-2.7 GHz Up to 100 Mbps per sector 5, 10, 20 MHz channel BW HBS:
• Connectorized ODU
• External antenna - 90° @ 3.x GHz, 60° @ 2.5 GHz
HSUs
• 20 Mbps aggregate only
• Integrated , Connectorized antenna All other features are similar to 5.x
The Unique P2MP SolutionThe Unique P2MP Solution
NetAstra Unique Selling Points
Highest Base Station capacity for the best user experience – 200Mbps
Highest spectrum efficiency for grater ROI - ~ 5bps/Hz
Secured Service Level Agreement for demanding applications
Low latency
Compact Subscriber Units (SUs) with low visual impact
Co-exist with NetStream Point to Point links
Long Range -40km
Carrier grade solution
NetAstra HPMP – Main Features
Service
Radio Performance
Configurable Maximum Information Rate (MIR) per SU
Enhanced QoS – 4 level queue per SU Networking features – VLAN, QinQ per SU Long Range – 40km @ 20Mbps
Advanced OFDM & MiMO 2x2 / Diversity for nLOS performance Enhanced interference mitigation capability Inter & intra site sync. to reduce self interference Dedicated traffic bandwidth allocation ensuring SLA & latency Low latency, min < 3msec , typical 4 to 10msec Channel BW – 10, 20, 40 MHz Regulation- FCC/ETSI/WPC/UNI /MII
NetAstra HPMP – Main Features – ctd.
Operational
Multi band Base Stations and SUs Simple to deploy Fully integrated with Netronics Lagacy solutions:
Coexists with NetStream 5x10/25/50/200 and NetStream 5x06/36
Common Link Manager Common NMS
User 1 - QPSK User 2 - 64 QAM User 3 - 64 QAM
Competition NetAstra
Secured Service Level Agreement – Example
Unexpected reduction of User-1 performance (e.g. lower modulation than planned) doesn’t affect Other Netronics users in the sector except user 1. Thus, securing others’ SUs SLA
User 1 - 64QAM User 2 - 64QAM User 3 - 64QAM
X Mb X Mb X Mb
Effective Capacity (Mbps) @ User 1 modulation is lower than planned
X MbX Mb
X/4 Mb
X/2 Mb
X/2 MB X/2 Mb
Planned Capacity (Mbps)
Dedicated VS. Shared BW Allocation
Attribute Shared BW Allocation NetAstra Dedicated BW allocation
BW allocation Upon traffic Fixed, configurable
Efficient when…Many users in a sector,Users’ throughput is low
Few users in a sector, Users’ throughput is high
Over-Subscription1:N N users per channel
1:1 Single user per channel
User average rate Depends on traffic load Depends on the configuration
What enables SLA? CIR / MIR Fixed allocation time per user
Is SLA guaranteed No Guaranteed
Service latency Long and variable Short
26
NetAstra PtMP system employs a Dedicated BW allocation which allows operators and service providers guarantee high-end services to their end-customers
32 HSUs per HBS HBS supports up to 32 HSUs Better BW allocation granularity per HSU No backward compatibility with releases prior to 3.3
Topic Before Release 3.3 Release 3.3
Max number of HSUs 16 32
Total Number of Time-Slots 16 64
Min Number of Time-Slots per HSU
1 2
Max Number of Time-Slots per HSU
8 32 (half HBS capacity)
Max Time-Slot Throughput6.25 Mbps @ 20 MHz12.5 Mbps @ 40 MHz
1.56 Mbps @ 20 MHz3.12 Mbps @ 40 MHz
Max Delay per HSU 21 msec 40.5 msec
Min Delay per HSU 2.25 msec 2.25 msec
27
32 HSUs per HBS (continued)
1. Time Slot duration is equal (1.25 ms)2. Number of TSs increased by 4 times (16 >> 64)3. TS capacity decreased by 4 times (6.25 >> 1.56 Mbps @ 20 MHz) which improves
capacity granularity per HSU
20msec
80msec
28
1.25ms
32 HSUs per HBS (continued) Use case #1:
• Channel BW: 20 MHz • Customer required capacity: 3 Mbps
Topic Before Release 3.3 Release 3.3
Required TS 1 2
Actually used capacity 6.25 Mbps 3.12 Mbps
Not used capacity 3.25 Mbps 0.12 Mbps
% not used capacity 108% 4%
29
32 HSUs per HBS (continued) Use case #1:
• Channel BW: 20 MHz • Customer required capacity: 19 Mbps
Topic Before Release 3.3 Release 3.3
Required TS 4 13
Actually used capacity 25 Mbps 20 Mbps
Not used capacity 6 Mbps 1 Mbps
% not used capacity 31.58% 7%
30
32 HSUs per HBS (continued)
User Required Capacity [Mbps]
Act
ual
Cap
acit
y [M
bp
s]
Unused BW
Required Capacity
31
MobilityMobility
Mobility, Nomadic & Fixed modesFixed: Fixed HSU is permanently installed on specific location HSU synchronize and register only to a specific HBS Administrator manually allocate a service and register the HSU to the
HBS only after the HSU synchronized to HBS
33
Mobility, Nomadic & Fixed modesNomadic: Nomadic HSU may move from one BS to another BS but gets service only while
on stationary position ETH service is provided when user is in a stationary position only Service is pre-configured to HSU
HBS1
HBS2
34
No Service
Mobility, Nomadic & Fixed modesNomadic: Nomadic HSU may move from one BS to another BS but gets service only while
on stationary position ETH service is provided when user is in a stationary position only Service is pre-configured to HSU
HBS1
HBS2
35
Service Available
Mobility, Nomadic & Fixed modesNomadic: Nomadic HSU may move from one BS to another BS but gets service only while
on stationary position ETH service is provided when user is in a stationary position only Service is pre-configured to HSU
HBS1
HBS2
36
No Service
Mobility, Nomadic & Fixed modesNomadic: Nomadic HSU may move from one BS to another BS but gets service only while
on stationary position ETH service is provided when user is in a stationary position only Service is pre-configured to HSU
HBS1
HBS2
37
Service Available
Mobility, Nomadic & Fixed modes
Mobility: Mobile Unit (HMU) enjoys continuous service while in motion from
different HBSs in the network seamlessly Service is pre-configured
38
Stronger Signal
Weaker Signal
Mobility, Nomadic & Fixed modes
Mobility: Mobile Unit (HMU) enjoys continuous service while in motion from
different HBSs in the network seamlessly Service is pre-configured
39
Stronger Signal
Weaker Signal
NetAstra AUM 5x200 Tput VS. RangeAntenna: Vehicle 10 dBi, Base-Station: 15 dBiFrequency: 5.8 GHzRate: Adaptive (Diversity)Fade margin: 6 dB
Maximum Throughput
40
40 MHz
20 MHz
10 MHz
5 MHz
NetAstra AUM 5x200 Tput VS. RangeAntenna: Vehicle 10 dBi, Base-Station: 15 dBiFrequency: 5.8 GHzRate: Adaptive (Diversity)Fade margin: 10 dB
Typical Throughput - based on Max Rate 16 QAM 3/4
41
40MHz
20MHz
10MHz
5MHz
NetAstra HMU 5x100 Tput VS. RangeAntenna: Vehicle 10 dBi, Base-Station: 15 dBiFrequency: 5.8 GHzRate: Adaptive (Diversity)Fade margin: 6 dB
Maximum Throughput
42
40 MHz
20 MHz
10 MHz
5 MHz
NetAstra HMU 5x100 Tput VS. RangeAntenna: Vehicle 10 dBi, Base-Station: 15 dBiFrequency: 5.8 GHzRate: Adaptive (Diversity)Fade margin: 10 dB
Typical Throughput - based on MAX rate 16 QAM 3/4
43
40 MHz
20 MHz
10 MHz
5 MHz
Sector Aggregate Capacity vs. Channel BW @ 5.x GHz
Cap
aci
ty [
Mb
ps]
Distance [Km]
16.5
200 Mbps over 3.7 Km
120 Mbps over 10 Km
•HBS antenna -15 dBi•HSU antenna – 23 dBi•For 5 MHz Channel BW it is recommended to use NetAstra SU 5x10 only
40MHz
20MHz
5MHz
10MHz
Feature ReviewFeature Review
Asymmetric BW Allocation• Enables 200 Mbps aggregate throughput per sector• Increases range per given throughput• Full scale Fixed UL/DL ratios:
CBW Ratio
40 & 20 MHz 92% / 8%
10 MHz 83% / 17%
5 MHz 70% / 30%
Attention: Same UL/DL ratio should be configured for all sectors in close
proximity The configured UL/DL is applicable to all HSUs in the sector Online configuration - No service interruption46
Spectrum Viewer: HBS & HSU • Built-in spectrum analysis tool, enables selection of the
best channel
• Enable to perform spectrum analysis outside of the operating band
Enable define spectrum analysis from 1 min – 24 hours (resolution in seconds)
• Spectrum viewer operational modes:
– Per whole sector (HBS + HSUs)
– Per HSU – Directly or remotely via HBS
– Note: Service is affected during operation
Max Interference report for all sector (DL)
47
Automatic Channel Selection (ACS)
The HBS Sector Radio scans all available channels (user configurable) looking for the channel with less noise
The channel with best performance will be assigned and inherited by registered HSUs
Once a channel is being used, the radios monitor that the service is being provided at acceptable quality
48
CH1 CH2 CH3 CH ‘N’
Consider relevant
Consider relevant
Consider relevant
Consider as “Not relevant”
…
Co – Location Interference
f1
f2
Mutual interference
When several HBS sector
radios/PtP radios are
collocated at a common hub
site, interference may occur
from one unit to another.
HBS
HBS
HSUs
HSUs
49
Hub Site Synchronization
HSS Eliminates the
Interference between the
collocated units by
synchronizing the TX and the
RX of collocated radios
HSS can also be connected to
a GPS receiver (GSU) to allow
synchronizing multiple sites
f1
f2HBS
HBS
HSUs
HSUs
HSS
50
Setting TX Ratio
51
92%
AU
• The HBS transmission ratio can be set to support symmetric (50/50) or asymmetric BW allocation
• The HBS TX ratio of the Downlink & Uplink is inherited by the sector HSUs• When installing collocated HBS radios, all radios must utilize the same TX ratio• The TX Ratio allocation is fixed (non-adaptive)
8%
92%
8%92%
8%UL/DL = 8/92
ApplicationsApplications
NetAstra – Value Proposition
High capacity connectivity to BW demanding & high-end applications in urban to rural deployments:
Service Providers
• Access business users with demand for high capacity and SLA
• Rural and remote broadband connectivity
• Backhaul of access solutions –e.g. Wireless PtMP and landline DSLAM
Government & Enterprise Networks
• HQ - branches broadband connectivity
• Utilities connectivity
• Gov. networks connectivity– e.g. education, Health care
• Access for high capacity video surveillance cameras
Urban - High Capacity SLA Corporate Access
NetAstraAU 5x200
SU 5xxx Sector Capacity- 92Mbps• 7 clients @ 6Mbps
• 3 clients @ 10Mbps
• 1 client @ 20Mbps
SUs range 2km @20MHz Channel BW
Sector Capacity- 75Mbps• 7 clients @ 5Mbps
• 2 clients @ 10Mbps
• 1 clinet @ 20 Mbps
SUs range 6km @20MHz Channel BW
Service Provider Application
Urban - High Capacity Corporate Access
NetStream 5x200
Service providerNetwork
Service ProviderPremises
NetAstraAU 5x200
Multi sectors can be backhauled with NetStream 5x200
Service Provider Application
Medium Capacity Corporate Access - Self Backhaul
Built in backhaul from AU site to the Service Provider premises
Assumption that the provider premise is located within the served sector
Service providerNetwork
Service providerPremises
Corporate 20 Mbps Corporate 20 Mbps
Corporate 10 Mbps
NetAstraAU 5x200
Service Provider Application
Sub Urban - Medium Capacity Corporate Access
Single ODU covers 2 sectors using 2 uni-polarized antennas (SIMO), one per sector
Capacity- each sector up to 25 Mbps
Single
Service providerNetwork
Service Provider Application
NetAstraAU 5x200
NetStream 5x200
Service providerPremises
Rural Broadband – Connecting Communities
Broadband connection to remote communities
Service providerNetwork
Sector Capacity- 30Mbps
• 5 villages @ 6Mbps
SU range 30km @20MHz Channel BW
Sector Capacity- 48Mbps
• 8 villages @ 6Mbps
SU range 20km @20MHz Channel BW
Service Provider Application
NetAstraAU 5x200
NetStream 5x200
Service providerPremises
Safe City –Video surveillance
Access to high capacity cameras, collocated cameras
Backhaul of mesh WiFi cloud, carrying Video surveillance
NetStream 5x200
Service providerNetwork
High resolution Camera
Collocated Cameras
Private Network Application
NetAstraAU 5x200
Service providerPremises
High Capacity Inter-Office connectivity
HQ
Two modes of operations:
• WLAN : Traffic from branch to branch is switched back by the AU
• Access : Higher network hierarchy switches the traffic
Private Network Application
NetAstraAU 5x200
Success StoriesSuccess Stories
Rural connectivity in Peru
62
Three regions, two of which are complex Andean regions due to topography and population
Customer: Peruvian Government, FITEL
Challenges:
Project drivers: social inclusion reach out to the rural
Services provision to >200 remote villages: Telephony, data services, private lines to businesses in some villages
Why Netronics:
End to End offering – Backhaul and Access , PtP and PtMP High coherency between the Radio planning and field trail resultsQoS and SLA
ISP in Netherland
Customer: An ISP , serves a wide base of corporate clients, among them large and small businesses, universities, medical centers and banks
Challenge :
Meet the need of bandwidth demanding corporate client applications. Harsh winter climate in the region and in scenarios with no direct line-of-sight.
Why Netronics:
63
“What we love about NetAstra HPMP is that it provides up to 100 Mbps full duplex dedicated symmetrical throughput and dedicated bandwidth, which is something that no other product in the market today can claim.”
CEO
ISP in Ireland
The Customer:
A leading Wireless ISP, provides broadband services in Ireland’s Mid & South West Region. Specializing in the provision of cost-competitive broadband to rural areas to residential, small business and corporate. From 2010 provides speeds of up to 10 Mb download and 8Mb upload.
Challenge:
Providing cost-competitive broadband service to demanding corporate customers in suburban and rural areas
Base Station
64
Telco Tanzania Customer:
Telecom provider, based in Dar es Salaam. Offering wide rang of Telecom services: mobile, International call, and fixed broadband
Challenge:
Reliable, fast and affordable symmetrical connectivity for Tanzanian businesses located in very dense urban areas
65
Thank youThank you
www.netronics-networks.comwww.netronics-networks.com