networkdesign ppts

20
Network Proposal

Upload: shwetasharma112

Post on 15-Jun-2015

699 views

Category:

Education


0 download

DESCRIPTION

mdf/idf

TRANSCRIPT

Page 1: Networkdesign ppts

Network Proposal

Page 2: Networkdesign ppts
Page 3: Networkdesign ppts

Mdf

Page 4: Networkdesign ppts
Page 5: Networkdesign ppts

Planning Process

Brainstorm• Size of building• Current

network in existing buildings

• Staff/Student needs

• Equipment

Page 6: Networkdesign ppts

Data ClosetsThe properties of the data closets will be

• room temperature will be kept between 68  - 70 • adequately vented• relative humidity between 30% and 50%• no fluorescent lighting• plenty of isolated ground power outlets• dedicated power and generator• wide doors• more than 3 feet of space behind data racks• fire suppression• restricted access via electronic access control; door

hardware/locking mechanism should be fail secure 

The 10000 G2 Series Rack includes cooling and cable management. Front and rear door handles provide easy access while lock bars provide added security.

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

Page 7: Networkdesign ppts

MDF• One Main Distribution Facility

(MDF) will be located in a room on the first floor common area, near the media center. The HP ProCurve Secure Router will select the best path for data by looking at the IP addresses.

• The controller, Aruba 3000, will connect to WAN (Administration Building). This Domain Controller will control communication and share and store information, while the file and print server will “hand out” the addresses of the network.

• E-mail, student information systems, grades, and business systems will be controlled by the WAN server in the administration building.

C

E

G

D

F

H

I

K

J

L

Power

Fault

Locator A

ProCurve NetworkingHP Innovation

Console Auxiliary PortInternalPower

PoEPwr

2

1

2

4

1

3

PoE

Temp

Fan

Flash

DIMM

Mgmt

ChasTest

B

Reset Clear

ProCurve Switch 5400zlManagement ModuleJ8726A

PoE

ProCurveSwitch 5412zlJ8698A

Usezl Modules

only

Status

Modules

K

I

G

F

D

B

E

C

A H

J

LLED Mode

Usr

PoE

Act

FDx

Spd

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

POWER

STAT US

3200

0

1000ACT

LNK

ACT

LNK

1

1000ACT

LNK

ACT

LNK

2

1000ACT

LNK

ACT

LNK

3

LNK

ACT

LNK

SERIAL

1000ACT

n e t w o r k s

zlProCurve24p SFP

zl Module J8706A Use ProCurve mini-GBICs and SFPs only

1 5

62

3

4

7 11

128

9

10

13 17

1814

15

16

19 23

2420

21

22

zlProCurve24p SFP

zl Module J8706A Use ProCurve mini-GBICs and SFPs only

1 5

62

3

4

7 11

128

9

10

13 17

1814

15

16

19 23

2420

21

22

zlProCurve24p SFP

zl Module J8706A Use ProCurve mini-GBICs and SFPs only

1 5

62

3

4

7 11

128

9

10

13 17

1814

15

16

19 23

2420

21

22

zlProCurve24p SFP

zl Module J8706A Use ProCurve mini-GBICs and SFPs only

1 5

62

3

4

7 11

128

9

10

13 17

1814

15

16

19 23

2420

21

22

zlProCurve24p SFP

zl Module J8706A Use ProCurve mini-GBICs and SFPs only

1 5

62

3

4

7 11

128

9

10

13 17

1814

15

16

19 23

2420

21

22

zlProCurve24p SFP

zl Module J8706A Use ProCurve mini-GBICs and SFPs only

1 5

62

3

4

7 11

128

9

10

13 17

1814

15

16

19 23

2420

21

22

UID

1

2

HPProLiantDL360

G5

UID

1

2

HPProLiantDL360

G5

Page 8: Networkdesign ppts

Common AreaCommon Area

Page 9: Networkdesign ppts

IDF• One Intermediate

Distribution Facility (IDF) will be placed in the middle on the each of each learning community.

• Two switches will offer redundancy.

• Fiber uplinks from the switch will be a good investment.

• UPS will be in place in case of power failure.

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

47

46

45

44

43

47

46

45

44

43

+- +-

!

hp T2200 XR

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

47

46

45

44

43

47

46

45

44

43

7

6

12

13

19

18

24

J4820A 24 port 10/100TX13 14 15 16

19 20 21 22

5 6

11 12

1 2 3 4

7 8 9 101

17 18

23 24

hp procurve10/100TXxl Module J4820A

xl

7

6

12

13

19

18

24

J4820A 24 port 10/100TX13 14 15 16

19 20 21 22

5 6

11 12

1 2 3 4

7 8 9 101

17 18

23 24

hp procurve10/100TXxl Module J4820A

xl

7

6

12

13

19

18

24

J4820A 24 port 10/100TX13 14 15 16

19 20 21 22

5 6

11 12

1 2 3 4

7 8 9 101

17 18

23 24

hp procurve10/100TXxl Module J4820A

xl

C

E

G

D

F

H

I

K

J

L

Power

Fault

Locator A

ProCurve NetworkingHP Innovation

Console Auxiliary PortInternalPower

PoEPwr

2

1

2

4

1

3

Po E

Tem p

Fan

Flash

DIMM

Mg m t

ChasTest

B

Reset Clear

ProCurve Switch 5400zlManagement ModuleJ8726A

PoE

ProCurveSwitch 5412zlJ8698A

Usezl Modules

only

Status

Modules

K

I

G

F

D

B

E

C

A H

J

LLE D Mo de

Usr

Po E

Act

FDx

Sp d

C

E

G

D

F

H

I

K

J

L

Power

Fault

Locator A

ProCurve NetworkingHP Innovation

Console Auxiliary PortInternalPower

PoEPwr

2

1

2

4

1

3

Po E

Tem p

Fan

Flash

DIMM

Mg m t

ChasTest

B

Reset Clear

ProCurve Switch 5400zlManagement ModuleJ8726A

PoE

ProCurveSwitch 5412zlJ8698A

Usezl Modules

only

Status

Modules

K

I

G

F

D

B

E

C

A H

J

LLE D Mo de

Usr

Po E

Act

FDx

Sp d

7

6

12

13

19

18

24

J4820A 24 port 10/100TX13 14 15 16

19 20 21 22

5 6

11 12

1 2 3 4

7 8 9 101

17 18

23 24

hp procurve10/100TXxl Module J4820A

xl

7

6

12

13

19

18

24

J4820A 24 port 10/100TX13 14 15 16

19 20 21 22

5 6

11 12

1 2 3 4

7 8 9 101

17 18

23 24

hp procurve10/100TXxl Module J4820A

xl

7

6

12

13

19

18

24

J4820A 24 port 10/100TX13 14 15 16

19 20 21 22

5 6

11 12

1 2 3 4

7 8 9 101

17 18

23 24

hp procurve10/100TXxl Module J4820A

xl

7

6

12

13

19

18

24

J4820A 24 port 10/100TX13 14 15 16

19 20 21 22

5 6

11 12

1 2 3 4

7 8 9 101

17 18

23 24

hp procurve10/100TXxl Module J4820A

xl

Page 10: Networkdesign ppts

Learning Learning CommunityCommunity

(six total in building)(six total in building)

Page 11: Networkdesign ppts
Page 12: Networkdesign ppts

Bandwidth

• Dallastown’s Intermediate Building will need 100MB bandwidth. In order for all Internet traffic to be managed in one place, Internet access, provided by Comcast, will come from the Administration building. The switches will support 10GB backbone (IDF to MDF).

Page 13: Networkdesign ppts
Page 14: Networkdesign ppts

Cabling• On each floor (2 floors) of each learning community (3 wings), we

have planned for fiber-optic backbone between wiring closets (IDF to MDF), with two strands running from each switch. Fiber optic cable has the ability to transmit signals over much longer distances and can carry information at greater speeds than coaxial and twisted pair. Other advantages of fiber include expansive bandwidth, low attenuation, electromagnetically isolated, great distance between repeaters, and enhanced security (difficult to eavesdrop).

 • Cat6 cables will connect the patch panels to the classrooms. Cat6,

rated to 1000 Mbs (Gigabit Ethernet) are currently industry standard. Four cables will run from each switch to the outlets in the classrooms. A cable tray will be installed every five feet in order to support the cables that are run horizontally. Five drops will be installed in each classroom. An outlet will be placed near the teacher’s station and the others will be installed in a bank along one wall of each of the classrooms.

Page 15: Networkdesign ppts

Cabling Rules

When running cable, it is best to follow a few simple rules: ·   Always use more cable than you need. Leave plenty of

slack. ·   Test every part of a network as you install it. Even if it is

brand new, it may have problems that will be difficult to isolate later.

·   Stay at least 3 feet away from fluorescent light boxes and other sources of electrical interference.

·   Label both ends of each cable. ·   Use cable ties (not tape) to keep cables in the same

location together. ·   Keep records.

Page 16: Networkdesign ppts

Wireless• Due to the need for flexibility within the

classroom, a wireless network is a natural complement to a wired system. The controller manages the channels for the wireless connections in the classrooms. Access Points will be located in each classroom, workroom, project room, science lab, and office and are connected to the IDF via cat6 cables. Additionally, Access Points will be located in the gym, auditorium, cafeteria, music room, media center and offices. Aruba AP60 access points will be purchased.  The price for these access points is very competitive and wireless offers greater access and more mobility.

60

PWR WLAN

ENET

Page 17: Networkdesign ppts

Testing Documentation

• Network drops will be numbered incrementally.• IP addresses will be used to name the switch

electronics. • Connectivity tests will be done to verify IP

addresses and Internet connection. • Visio diagrams and wiring maps will be kept to

document network. • Passwords, firewalls and Internet content filters

are some of the security measures that are located in the Administration Building.

• Security considerations will be balanced with user convenience.

Page 18: Networkdesign ppts

• Web 2.0 Tools – wikis, blogs, social networks, etc.

• Portable Digital Devices – laptops, mp3 players, PDA, cell phones, etc.

• Interactive Whiteboards and Projectors • General Productivity Tools

– word processors, spreadsheet, slide presentation programs, databases

• Multimedia Projects– PhotoStory, Movie Maker, Digital Streaming

• Internet Tools/Resources – e-mail, search engines, creative commons, wireless access,

video on demand

APPLICATIONS

Page 19: Networkdesign ppts

Item/Make/Model Location QTY Cost Total

         HP ProCurve Switch 5412zl Intelligent Edge (J8698A) MDF/IDFs 13 $3,404.99 $44,264.87

HP ProCurve Secure Router 7203dl (J8753A) MDF 1 $1,649.00 $1,649.00

HP Proliant Servers DL360 MDF 2 $4,949.00 $9,898.00

HP Proliant BL Patch Panels MDF/IDFs 49 $1,150.00 $56,350.00

Network Blocks Classrooms/common areas 627 $2.69 $1,686.63

Wall Plates Classrooms/common areas 627 $1.25 $783.75

Aruba AP60 Access point Classrooms/common areas 320 $289.99 $92,796.80

Aruba 3600 Controller MDF 1 $8,429.99 $8,429.99

T1500 G3 UPS MDF/IDFs 7 $478.00 $3,346.00

HP 10000 G2 Series Rack MDF/IDFs 14 $2,539.00 $35,546.00

Fiber Optic Cabling MDF - - IDF 1 $674.50 $674.50

Cabling - Cat6 (4 colors) Thru building 112 $129.00 $14,448.00

3ft patch cables cat6 MDF/IDFs 1151 $3.00 $3,453.00

Connectors RJ45 Cat 6 cables 2302 $0.20 $460.40

Fiber Optic Connectors Fiber Optic Cables 24 $13.76 $330.24

         

Project Total $274,117.18

Budget

Page 20: Networkdesign ppts

Conclusion

The educated person of the 21st century will be a life-long learner who knows how to access information and turn it into meaningful knowledge. Technology will be the universal tool for life.

 