new data sheet: tembreak 2 pvs400-ndh mccb for use … · 2017. 1. 26. · data sheet: tembreak 2...
TRANSCRIPT
-
Max In (A) of Frame
ModelNumber of PolesType
Nominal current ratings
Electrical characteristics
Rated insulation voltageRated impulse voltage
Ultimate breaking capacity(IEC, JIS)
Service breaking capacity(IEC, JIS)
Protection
Fixed thermal, fixed magneticAdjustable thermal, fixed magneticMagnetic trip only (adjustable)
Installation
Front connection (FC)Extension bar (FB)Rear connection (RC)Plug-in (PM)DIN rail mounting (DA)Dimensions
Weight
Operation
Direct Opening ActionToggle operationBreaker mounted (HB)Door mounted (HS)Motor operation
Endurance
MCCB Electrical Characteristics to IEC 60947-2, EN 60947-2, JIS C 8201-2-1 ANN.1,
Frame reference Quantity Unit Condition TB2 H/L 400
3 (4)NDH
250,400
(1150)8
5 ----
-5
---
••--
260-
185103
-5.6
•••
-1,000
-4,000
In
U iU imp
Icu
Ics
heightwidth
depthweight
Electrical
Mechanical
50°C
AC 50/60 Hz
1000V DC750V DC600V DC500V DC350V DC
1000V DC750V DC600V DC500V DC350V DC
3 pole4 pole
3 pole4 pole
1000V DC750V DC
350 - 600V DC-
(A)
(V)(kV)
(kA)
(kA)
(mm)(mm)
(mm)(kg)
cycles
cycles
DATA SHEET: TEMBREAK 2 PVS400-NDH MCCBFOR USE ABOVE 250V DC
400PVS400
Page 1 of 3
Connect all poles in series. The time constant (L/R) of the circuit should be less than 2.0ms nearby
rated current less than 5ms for short circuit < 10kA less than 10ms for short circuit < 20kA less than 15ms for short circuit > 20kA
-
CL CL
CL
CL CL CL CL
HL
L
HL
HL
HL
H
4P
4P26
0
86.998.6
8
214
104.6
228
90102
116
13.1
110
45
45 4570 115
51
129.1146.645
185
3014
.544
.530(max.)12
ø148
ø11
420
60 6060 60 60
126.581.5
14.5
30 44.5
349
260
118
92
R6
36.598.68
90102
104.6
228
260
830
ø13129.1
30 45 45 45
104.
610
8.4
68.4
15391
539
214
45
228
45 45 45
ø36ø1
3
(max
.)
52.5
1.6t
37.68
1.6t
36.6
100
146.6
Interpole barrier(removable)
Mounting hole
Insulating plate
Insulating plate
ON side : 37.6OFF side : 36.6
M10 screw
M6Mounting screw
Trip button (red)
M6Tapped hole
Con
duct
or
over
lap,
max
Con
duct
or
over
lap,
max
Stud can be turned 45° or 90°
Mounting plate
Insulating plate
Insulating plate
Interpole barrier
M6Tapped hole
Drilling plan (front view) Panel cutout (front view)
Preparation of conductor With extension bars (optional) Drilling plan (front view)
Panel cutout dimensions shown give an allowance of 1.0mm around the handle escutcheon.
Front-connected
Rear-connected
Note: See section 4 for the installation of the insulating plate.
Note: Studs are factory installed in horizontal direction both on the line and load sides.See section 4 for the installation of the insulating plate.
DATA SHEET: TEMBREAK 2 PVS400-NDH MCCB FOR USE ABOVE 250V DC Outline Dimensions PVS400-NDH (4P)
ASL: Arrangement Standard Line HL: Handle Frame Centre Line Front connected
Page 2 of 3
-
100
125
200
300
400
500
700
1000
1500
2000
3000
4000
5000
8000
0.005
0.01
0.02
0.040.06
0.1
0.2
0.40.6
1
2
6
4
10
203040
1
2
6
4
10
203040
1
3
2
seco
ndm
inute
hour
Tripp
ing T
ime
Percent Rated Current
Percent Rated Current
Time/Current Characteristic Curves PVS400-NDH 3P
Page 3 of 3
DATA SHEET: TEMBREAK 2 PVS400-NDH MCCBFOR USE ABOVE 250V DC