new features in janisoft 2019 r3 english...(since 2019 r2 sp02) in the item data register, you set...
TRANSCRIPT
Document author Nazmi Shtavica Created October 2019
File name Neuheiten_JANIsoft_2019_R3_EN.DOCX
Number of pages 25 © Software & Maschinen Services Public
New features
New features in JANIsoft 2019 R3
English
Documentation Version 2019 R3
German October 2019
Page 2 of 25
JANIsoft 2019 R3
Page 2 of 25
Table of contents
1 Program changes .............................................................................................................................................. 4 1.1 Design type, general .................................................................................................................................. 4
1.1.1 Unit processing .............................................................................................................. 4 1.1.2 Output of lists ................................................................................................................. 4
2 General changes/new features .......................................................................................................................... 5 2.1 Changes steel systems .............................................................................................................................. 5
2.1.1 CE marking for steel systems ........................................................................................ 5 3 Steel window systems ....................................................................................................................................... 7
3.1 Janisol Arte ................................................................................................................................................ 7 3.1.1 Bending radii, Janisol Arte 2.0 and Janisol Arte 66 ....................................................... 8 3.1.2 Janisol Arte 66 mm – New wide profiles ....................................................................... 9 3.1.3 Janisol window – Aluminium-laminated and integrated spacer tape........................... 10
3.2 Forms ....................................................................................................................................................... 11 4 Design type aluminium .................................................................................................................................... 12
4.1 Systems no longer available .................................................................................................................... 12 4.2 Changes to aluminium systems ............................................................................................................... 12
4.2.1 Calculation ................................................................................................................... 12 4.2.2 Output .......................................................................................................................... 13
4.3 Windows/doors, aluminium ...................................................................................................................... 14 4.3.1 Schüco AWS 50/65/70: ............................................................................................... 14 4.3.2 Window systems AWS 60-90: ..................................................................................... 14 4.3.3 Window fittings ............................................................................................................. 14 4.3.4 General modifications, window systems ..................................................................... 15 4.3.5 Schüco door fittings ADS: ............................................................................................ 15 4.3.6 Unit processing ............................................................................................................ 16 4.3.7 Technical settings ........................................................................................................ 17 4.3.8 Barcode for fittings table: ............................................................................................. 17
5 Folding industrial doors steel ........................................................................................................................... 18 5.1 Jansen folding doors, type of operation “Manual” ................................................................................... 18
6 Sliding units aluminium .................................................................................................................................... 18 6.1 Schüco ASE 67 PD .................................................................................................................................. 18 6.2 Schüco ASS 77 PD.HI, Schüco ASS 77 PD.NI ....................................................................................... 20 6.3 Schüco ASS 39 PD.NI ............................................................................................................................. 21 6.4 Schüco ASS 80 FD.HI ............................................................................................................................. 21 6.5 Unit processing ........................................................................................................................................ 21 6.6 Schüco ASS 70.HI Design Edition ........................................................................................................... 22 6.7 Technical settings .................................................................................................................................... 22
6.7.1 Schüco ASE 67 PD: .................................................................................................... 22 6.7.2 Forms ........................................................................................................................... 22
7 Façades aluminium .......................................................................................................................................... 23 7.1 Unit processing ........................................................................................................................................ 23 7.2 Technical settings .................................................................................................................................... 23 7.3 Security systems (aluminium) .................................................................................................................. 24
7.3.1 CE marking .................................................................................................................. 24
Documentation Version 2019 R3
German October 2019
Page 3 of 25
JANIsoft 2019 R3
Page 3 of 25
7.3.2 Unit processing ............................................................................................................ 24 7.3.3 Forms ........................................................................................................................... 25 7.3.4 Sun shading ................................................................................................................. 25
The new features and changes are described in general terms. The availability of the systems, materials and functions depends on which edition of the program you have.
Please also consider the notes in the cover letter for the version that is appended as a PDF document in the program directory ...\“ServiceDesk\Documents” in the PDF file format.
The cover letter pertaining to changes that are made to the version with forthcoming service packs can be found in the menu ribbon under General > Help > Program informat ion > Serv ice Pack XY > Detai ls .
If you have any questions about further improvements in the version our Service Desk colleagues will be happy to assist you.
Documentation Version 2019 R3
German October 2019
Page 4 of 25
JANIsoft 2019 R3
Page 4 of 25
1 Program changes
1.1 Design type, general
1.1.1 Unit processing
Panic doors labelled (EN 179 or EN 1125):
Symbols
Starting with this version, an additional symbol will be shown in anti-panic doors that conform to EN 179 or EN 1125.
The symbols are on the layer for the opening symbols. If you have hidden this layer in the Def ine unit appearance dialogue, the symbols will not be shown.
1.1.2 Output of lists
Materials list:
Optional output of the article descriptions from the article management
Starting with this version, you will find in the output options for the materials list under the group Addit ional informat ion on the ar t ic le the new property Art ic le descr ipt ion from ar t ic le management . If you tick this check box, the article descriptions from the article management will be output for the articles instead of the purposes.
Documentation Version 2019 R3
German October 2019
Page 5 of 25
JANIsoft 2019 R3
Page 5 of 25
2 General changes/new features
2.1 Changes steel systems
2.1.1 CE marking for steel systems
Starting with this version, the documents CE mark ing and Declarat ion of Per formance can be output for the following systems.
Steel windows/doors:
• Economy 50 E30
• Economy 50 RS DIN 18095
• Economy 60 E30
• Economy 60 RS DIN 18095
• Economy 60 RS burglar resistant
• Janisol 2 EI30
• Janisol 2 EI30 stainless steel
• Janisol C4
• Janisol burglar resistant
• Jansen Art15
Steel sliding systems:
• Janisol 2 EI30 fire-resistant sliding door
• Janisol Arte sliding doors
• Janisol lift-and-slide door
• Jansen sliding door
Steel folding sliding systems:
• Janisol folding wall
You set the defaults for the respective systems in the system default settings or specifically in the item for each opening in the Field propert ies dialogue.
➔About CE marking (for windows/doors and façades) You provide the CE information separately according to the classification reports. Automated calculation for the CE marking has top priority in our development pipeline.
Documentation Version 2019 R3
German October 2019
Page 6 of 25
JANIsoft 2019 R3
Page 6 of 25
Documentation Version 2019 R3
German October 2019
Page 7 of 25
JANIsoft 2019 R3
Page 7 of 25
3 Steel window systems
3.1 Janisol Arte
Settings for glazing now only specific for the opening:
The settings for the glazing (Glazing for windows , Glazing of f ixed l ights & doors ) have been removed from the technical settings for the Janisol Arte system.
For all new items created, you will find the properties in the Field propert ies dialogue under the group Glass/panel . There you make specific settings for each opening.
Nothing changes for items already created in the previous versions. For these items, the settings for the glazing are maintained in the item window in the Sett ings (Technical /Process ing) register.
Janisol Arte, material type “Galvanised”, design “With push-in gasket”:
Basic depth 66 mm entered
(Since 2019 R2 SP02)
In the I tem data register, you set your defaults for the entire item under the System/mater ial /prof i les group. Starting with this version, you can alternatively choose between the entries 60 mm or 66 mm in the new Basic depth field for the combination material type Galvanised and design With push- in gasket .
In the Field proper t ies dialogue, you define the basic depth for the field under the Prof i les group. As standard, your defaults are carried over from the item data.
The settings for the glazing can be specifically defined for each opening. For this you will find the properties in the Field propert ies dialogue under the group Glass/panel .
Documentation Version 2019 R3
German October 2019
Page 8 of 25
JANIsoft 2019 R3
Page 8 of 25
3.1.1 Bending radii, Janisol Arte 2.0 and Janisol Arte 66
Minimum bending radii, Janisol Arte 2.0 profiles
The following modifications have been made:
• Additional bending radii
• Message in the event of a shortfall
Type of profile Profile 1 Profile 2 Minimum bending radius in mm (R) L-profile 601.611 601.611.09 300 T-profile 602.611 602.611.09 300 Z-profile 603.611 603.611.09 300 H-profile 605.611 605.611.09 300
Type of profile Profile 1 Profile 2 Minimum bending radius in mm (R) L-profile 601.610 601.610.09 300 T-profile 602.610 602.610.09 300 Z-profile 603.610 603.610.09 300 H-profile 605.610 605.610.09 300
Type of profile Profile 1 Profile 2 Minimum bending radius in mm (R) L-profile 601.615 Z 601.615.09 525 L-profile 601.616 Z 850 T-profile 602.615 Z 602.615.09 625 T-profile 602.616 Z 950 Z-profile 603.615 Z 603.615.09 625 Z-profile 603.616 Z 1050 H-profile 605.615 Z 605.615.09 625
Minimum bending radii, glazing beads Arte 2.0
Glazing bead type Glazing bead 1 Glazing bead 2 Glazing bead 3 Minimum bending radius (R) Look 62.510GV+GZ 62.511GV+GZ** 62.512GV+GZ** 300 Steel angle 402.190 Z 402.191 Z 402.192 Z 300 Steel angle 402.990 402.991 402.992 300
Documentation Version 2019 R3
German October 2019
Page 9 of 25
JANIsoft 2019 R3
Page 9 of 25
Minimum bending radii, Janisol Arte 66 mm profiles
Type of profile Profile 1 Profile 2 Minimum bending radius in mm (R) L-profile 601.612 450 T-profile 602.613 450 Z-profile 603.612 603.612.09 450 H-profile 605.612 450
Minimum bending radii, glazing beads Arte 66 mm
Glazing bead type
Glazing bead 1
Glazing bead 2
Glazing bead 3
Glazing bead 4
Glazing bead 5
Minimum bending radius (R)
Aluminium glazing beads
405.031 405.032 405.033 405.034 405.035 440
3.1.2 Janisol Arte 66 mm – New wide profiles
New wide, profiles for Arte 66:
• 601.632Z (same purpose as 601.630Z)
• 602.632Z (same purpose as 602.630Z)
• 602.633Z (same purpose as 602.615Z)
• 603.632Z (same purpose as 603.630Z)
• 605.632Z (same purpose as 605.630Z)
• 601.645Z (same purpose as 601.612Z)
• 602.645Z (same purpose as 601.613Z)
• 603.645Z (same purpose as 603.612Z)
• 605.645Z (same purpose as 605.612Z)
• 600.612Z (same purpose as 600.609Z)
Documentation Version 2019 R3
German October 2019
Page 10 of 25
JANIsoft 2019 R3
Page 10 of 25
3.1.3 Janisol window – Aluminium-laminated and integrated spacer tape
Starting with this version, the new entry Spacer tape a luminium- laminated can be selected in the technical settings of the Janisol system under the group Glazing for windows or Glazing of f ixed l ights & doors when the glazing type Wet g lazing has been selected from the Spacer tape/g lazing gasket selection list.
With this selection, the self-adhesive spacer tape is calculated as the inside and outside glazing gasket for the glazing in the Janisol Primo system. (450.039 (14 × 4 mm), 450.040 (14 × 5 mm), 450.041 (14 × 6 mm).
Spacer tape aluminium-laminated for Janisol Primo profiles
Profiles:
• 601.635.6Z
• 602.635.6Z
• 603.635.6Z
• 605.635.6Z
• 601.685.6Z
• 602.685.6Z
• 603.685.6Z
• 605.685.6Z
• 601.634.6Z
• 600.002.6Z (edge profile)
• 602.634.6Z
Documentation Version 2019 R3
German October 2019
Page 11 of 25
JANIsoft 2019 R3
Page 11 of 25
3.2 Forms
Fire protection monitoring report:
Forms have been updated
(Since 2019 R2 SP02)
The following forms have been updated:
• Jansen Janisol 2 T30-19
• Jansen Janisol 2 T30-2
➔“Fire protection monitoring report” dialogue
Declaration of conformity for fire protection barrier:
Forms have been updated
The following forms have been updated:
• Janisol 2 T30 (updated since 2019 R2 SP02)
• Janisol C4 F90 (updated since 2019 R2 SP02)
• Economy 50 RS
• Economy 60 RS
➔“Declaration of conformity for fire protection barrier” dialogue
Documentation Version 2019 R3
German October 2019
Page 12 of 25
JANIsoft 2019 R3
Page 12 of 25
4 Design type aluminium
4.1 Systems no longer available
Window and door systems aluminium
The following system has been discontinued from the Schüco product range and is no longer offered in the new items program.
System
Schüco AWS 112.IC
4.2 Changes to aluminium systems
4.2.1 Calculation
Contacts:
Aluminium surface finish supplements – Fixed lengths
In the Contacts dialogue, new input possibilities for supplements for small bar lengths have been included for the system coater Schüco and for the coater templates for non-Schüco coaters.
In the conditions, you will find under the group Aluminium sur face f inish supplements new input fields for the following f ixed lengths :
<1001 mm
<3001 mm
<5001 mm
System coater Schüco:
Corresponding supplements are entered as percentages in the master data. For existing projects, the input fields are preset at zero so that the calculation does not change.
Non-Schüco coaters:
The input fields are preset at zero in the master data.
➔Properties list contact type “Coater” in the “Contacts” dialogue
Documentation Version 2019 R3
German October 2019
Page 13 of 25
JANIsoft 2019 R3
Page 13 of 25
4.2.2 Output
C2C in bronze and new in silver
Starting with this version, the C2C output is also possible in silver for the supported systems.
During the output of theC2C list, the program checks whether the framework conditions are fulfilled for an output in silver or bronze. For example, the article for C2C must be used for the C2C output in silver when a glazing rebate insulation is used. The corresponding certification symbol is printed in the document created. If an item does not meet the requirements for silver or bronze, you get an error list stating the reason.
The systems for which cradle to cradle certificates exist are supported. Information about the supported systems can be found in the program: Menu ribbon, register General > Help > Prof i le systems > Column C2C .
Requirements for output of the C2C list are for example:
• The vent must not be bonded (to attain security class RC2 and higher).
• No electrical/electronic components may be installed.
• No PT bars may be used.
• No PVC components may be installed.
Documentation Version 2019 R3
German October 2019
Page 14 of 25
JANIsoft 2019 R3
Page 14 of 25
4.3 Windows/doors, aluminium
4.3.1 Schüco AWS 50/65/70:
Single-leaf and double-leaf Window doors, easy-access with 20 mm threshold
For easy-access window doors with the selected option Inward-opening, easy-access balcony/pat io door , 20 mm threshold , starting with this version the fitting Schüco AvanTec SimplySmart can also be selected in the systems with the basic depths 50 to 70 mm.
4.3.2 Window systems AWS 60-90:
Glass bridges for RC glazing beads
The new glass bridges are calculated.
System Outer frame: Glass bridge Art. (PU)
Vent frame: Glass bridge Art. (PU)
AWS 90 288279 (100) 288280 (100)
AWS 75 265795 (40) 265796 (40)
AWS 70 265794 (40) 288168 (100)
AWS 65 288167 (100) 265795 (40)
AWS 60 233480 (100) 265794 (40)
4.3.3 Window fittings
Window fittings Schüco AvanTec SimplySmart and surface-mounted SimplySmart:
New minimum vent dimension for diagonal windows:
When calculating the window fittings Schüco AvanTec SimplySmart and surface-mounted SimplySmart, the minimum vent dimensions documented in the BK 1-3 SimplySmart – Schüco SimplySmart window f i t t ings (10.2019) are taken into account for diagonal windows.
Surface-mounted fitting discontinued
The surface-mounted fitting (fittings types BASIC – surface-mounted f i t t ing , etc.) can no longer be selected for the new T/S units. Existing items will remain unchanged.
Schüco SimplySmart top light fittings:
Burglar resistance RC2 and RC3
For the opening type 210: Top l ight , the top light fittings SimplySmart (OL 200 and OL 320) can be selected with security classes RC2 and RC3 starting with this version.
Schüco AvanTec SimplySmart burglar resistance RC1N, RC2:
Casing mechanism
The casing mechanisms Art. 277399 (AWS 60/70/75) and Art. 277400 (AWS 90) can be used for the units RC1N and RC2.
Requirements: a vent profile suitable for the application must be selected.
• Window doors: Selection only for the variants with zero level threshold.
Documentation Version 2019 R3
German October 2019
Page 15 of 25
JANIsoft 2019 R3
Page 15 of 25
• Turn/tilt and tilt before turn windows: Selection only for operating type Standard wi th reduced operat ing force .
4.3.4 General modifications, window systems
Schüco AWS 75 PD.SI:
Update BFK 1-1E (10.2019)
The calculation follows the updated order and fabrication documents.
Schüco AWS 120 CC.HI with CCB:
Cover profile Art. 265911 in combination with anodised profiles
When the sun shading system CCB is used in combination with anodised surface finishes, the new H-profile Art. 265911 is calculated as the cover profile instead of Art. 284894. With regard to this, please note the changes in the fabrication manual 1.1 (e.g. K1022536).
4.3.5 Schüco door fittings ADS:
New round tube handle bars (length 3 m) (BK1-4 (10.2019))
The new door pull bars of the round tube series can be entered. For calculating the door pull bars, you must select the desired bracket (Art. 279428 or Art. 279431) as Addit ional outer handle (or as Outer handle ).
If you select the Art. 279428, you have the option of defining the location of a third middle handle.
➔Door fittings: Handle bars
Documentation Version 2019 R3
German October 2019
Page 16 of 25
JANIsoft 2019 R3
Page 16 of 25
4.3.6 Unit processing
System templates, windows/doors:
New template “Corner window (E1) with corner mullion 90 degrees”
Starting with this version, a new template is also available for you to select in addition to the previously already available system templates Corner window (E1) and Corner window without corner mul l ion .
Corner window (E1) with corner mullion 90 degrees
System templates > 01 – Windows & Doors > 03 – Geometry > 05 – 3D
When you select this new template, corner windows (E1) are always assembled with a corner mullion. Changing the corner profile is possible in the item. The rule “Last used with the template” is not applied.
Schüco AWS 75 PD.HI:
Change to the axis dimension when using Art. 502670, 502680, 502690 and 502700 as mullion/transom
For the profile Art. 502670, 502680, 502690 and 502700 (purposes Mull ions and Transoms ), the reference has been moved 4.95 mm to the centre of the outer cavity.
Please note for existing items:
As a result of this correction, the axis dimension of the unit and thus all dependent vent and glass sizes change. Please check your affected items.
Documentation Version 2019 R3
German October 2019
Page 17 of 25
JANIsoft 2019 R3
Page 17 of 25
4.3.7 Technical settings
Window systems Schüco AWS:
Settings for the glazing rebate insulation
• The property AWS 65, AWS 70.HI g lazing rebate insulat ion has been renamed Glazing rebate insulat ion .
• The check box has been replaced by a selection list. You can now select your desired glazing rebate insulation option from this.
• Starting with this version, the property is also available for the following systems:
Schüco AWS 90.SI
Schüco AWS 90 BS.SI+
Schüco AWS 120 CC.SI
➔Technical settings, group U value calculat ion > Glazing rebate insulat ion
Schüco AWS 75 BS.SI+:
Settings for the glazing rebate insulation
Starting with this version, for the glazing of the asymmetrical mullion it is possible to select via the property Type of g lazing which glazing rebate insulation is to be calculated (use before the glazing or use after the glazing, standard or C2C standard).
➔Technical settings > Group U value calculat ion > Type of g lazing
Output of lists
4.3.8 Barcode for fittings table:
“Barcode 128” can now only be used with restrictions
Materials list, infill panel plan, unit overview, window vent and fittings list
Please note if you print in the named lists a code for the automatic processing of the locking bars: The barcode with Code 128 will in some instances no longer support all properties of the opening that is required for calculating the locking bars. Please use the QR code and, on the locking bar machine, the scanner with the Art. No. 289220.
See for example ➔ Settings for materials list
Documentation Version 2019 R3
German October 2019
Page 18 of 25
JANIsoft 2019 R3
Page 18 of 25
5 Folding industrial doors steel
5.1 Jansen folding doors, type of operation “Manual”
Changed vent widths
Automatic calculation of the vent widths has been corrected for the following opening combinations of the free vent combination (intersections 5, 6, 7).
• Odd and even
• Even and zero
• Even and even
Please note:
This change also affects the vent dimension of existing items.
6 Sliding units aluminium
6.1 Schüco ASE 67 PD
90-degree corners
(Outer frame/vent frame versions 57/57, 57/57 light, 90/90, 90/57SC and 57/90SC)
Starting with this version, corner units can be entered.
Double-track and triple-track 90-degree internal and external corners
Double-track and triple-track 90-degree corners can be created so that they correspond to the following order manual types:
Type 2D/1 90-degree A
Type 2D/1 90-degree I
Type 2C 90-degree A
Type 3F 90-degree A
Type 3F 90-degree I
As system templates, select the new templates (04 – Sl id ing uni ts -> 01 – Sl iding and l i f t and s l ide units ) in the Select template dialogue.
Documentation Version 2019 R3
German October 2019
Page 19 of 25
JANIsoft 2019 R3
Page 19 of 25
Double- track 90-degree corner (external double -vent)
Trip le- track 90-degree corner (external double-vent)
In the I tem proper t ies dialogue box, define the width of the vent and the position of the access leaf in the unit parameters. Via the unit parameter Corner conf igurat ion , you determine whether an external corner or an internal corner should be created.
For type 2C 90-degree A, change the opening type to : in the desired level for an external corner. F ixed f ie ld .
Double-track 90-degree all-glass corners as internal and external corners
Double-track 90-degree corners can be created so that they correspond to the following order manual types:
Type 2B 90-degree A
Type 2B 90-degree I
For the system template, in the Select template dialogue box select the template Double-track 90-degree a l l -g lass corner (04 – Sl id ing uni ts -> 01 – Sl id ing and l i f t and s l ide units ).
Double- track 90-degree a l l -g lass corner
In the I tem proper t ies dialogue box, define the width of the vent in the unit parameters. With the unit parameter Corner conf igurat ion , you determine whether an external corner or an internal corner should be created. Define the glass corner variant (mitre, butt with stepped glazing) in the unit parameter Glass design in corner .
If you have selected the Mitre option for the glass design of the corner, you must define in the technical settings how the mitre should be configured at the glass corners (group Glazing > Glass edge for a l l -g lass corner (mitre) ).
Calculating adhesive for additional bonding
Starting with this version, the adhesive required for bonding the infill with the vent is calculated (special adhesive Art. 288180, special adhesive Art. 288181 and surface activator Art. 265431).
Calculation of the required adhesive is done based on the processing guidelines documented in the order and fabrication manual. Additional amounts of adhesive to compensate for any bonding deviations must be entered as additional material.
Documentation Version 2019 R3
German October 2019
Page 20 of 25
JANIsoft 2019 R3
Page 20 of 25
6.2 Schüco ASS 77 PD.HI, Schüco ASS 77 PD.NI
Security classes
Starting with this version, the following types can be created in other security classes. When selecting the fittings type in the Field proper t ies dialogue, the selections are changed and added accordingly.
Types Fittings types, old Fittings types, new
Type 2A/1
Type 2A/1.2
Standard => Standard
RC1 capability => RC1N*
RC2N
RC2 capability => RC2*
No fittings => No fittings
* This change also affects the calculation of existing items.
Types Fittings types, old Fittings types, new
Type 2A
Type 2A.2
Type 2B
Standard => Standard
RC1N
RC2
RC2N
No fittings => No fittings
Schüco ASS 77 PD.HI, Schüco ASS 77 PD.SI, Schüco ASS 77 PD.NI
SNO/SNS sensor unit with finger trap protection SK2
The SNO/SNS sensor unit (Art. 262935) can be optionally calculated starting with this version. If the entry SK2 is selected in the Field propert ies dialogue under the group Fit t ing for the property Finger trap protect ion , you are offered the additional check box SNO/SNS sensor unit .
Documentation Version 2019 R3
German October 2019
Page 21 of 25
JANIsoft 2019 R3
Page 21 of 25
6.3 Schüco ASS 39 PD.NI
Interlock section profile with reinforcement (structural profile)
(Since 2019 R2 SP01)
Previously, the reinforcement option for the interlock section profile could be selected via the Modify sect ion function.
Since 2019 R2 SP01, it is possible to select in a selection list the option for reinforcement in the Field propert ies dialogue when the SLF interlock section profile is selected (Structura l prof i le smal l ins ide ; Structura l prof i le large ins ide ; Structura l prof i le large on both s ides ).
For existing items only, the entry 4: Modi fy sect ion is displayed and preset, and the original profile setting remains.
The vent widths are calculated according to the insert unit of the structural profiles.
➔Notes on Schüco ASS 39 PD.NI
6.4 Schüco ASS 80 FD.HI
Additional profiles Art. 430400 and Art. 430410 no longer pre-rolled
The additional profiles Art. 430400 and Art 430410 can no longer be ordered pre-rolled.
Please note:
If the setting in the master data for these articles was pre-rolled, starting with this version the setting will automatically be changed to customer-rolled.
If these articles were set to pre-rolled in existing items, these will now be automatically changed to customer-rolled.
➔About the pre-rolled profile code
6.5 Unit processing
Schüco ASE 60/80.HI Design Line:
New unit parameter “Type”
(Since 2019 R2 SP02)
Via the new unit parameter Type , you define how the centre section should be configured (dialogue I tem propert ies > Register I tem data > Group Unit parameters ).
When selecting Design Line , the narrow interlock section profile (Schüco ASE 60: Art. 494450; Schüco ASE 80.HI Art. 494410) is calculated.
Existing items are not changing. The selection for the unit parameter is preset in accordance with the interlock section profiles selected therein.
➔Schüco ASE 60/80.HI: unit parameter “Type”
Documentation Version 2019 R3
German October 2019
Page 22 of 25
JANIsoft 2019 R3
Page 22 of 25
6.6 Schüco ASS 70.HI Design Edition
Unit parameters “Type” – “Design Edition” selection renamed (since 2019 R2 SP02)
The selection Design Edi t ion for the unit parameter Type has been renamed Design Line . (Dialogue I tem propert ies > Register I tem proper t ies > Group Unit parameters ).
The calculation itself is not changing. When Design L ine is selected, the centre section is being built up in the usual way with a narrow double vent area in accordance with ASS 70.HI Design Edition.
➔Schüco ASS 70.HI: unit parameter “Type”
6.7 Technical settings
6.7.1 Schüco ASE 67 PD:
Colour setting for end stop and rebate buffer
(Technical settings > Group Colours )
• The technical setting Door holder has been renamed End s top .
• The technical setting Spacer has been renamed Rebate buf fer .
The possible selections in the selection lists remain unchanged.
➔Technical settings, windows/doors (aluminium)
6.7.2 Forms
Planning documents:
Schüco ASE 67 PD manufacturer’s checklist
Starting with this version, it is possible to call up the document Manufacturer ’s check l is t for the Schüco ASE 67 PD system.
General > Extras > Forms > ASE 67 PD and ASS 77 PD planning documents
➔“ASE 67 PD and ASS 77 PD planning documents” dialogue
Documentation Version 2019 R3
German October 2019
Page 23 of 25
JANIsoft 2019 R3
Page 23 of 25
7 Façades aluminium
7.1 Unit processing
Schüco FWS 50/60:
Unit parameters thermal insulation – Single glazing
Starting with this version, the entry Single g lazing can be selected for units of the systems Schüco FWS 50 and Schüco FWS 60 for the unit parameter Thermal insulation. This selection allows single glazings of 4 to 14 mm.
7.2 Technical settings
Schüco FWS 50/60:
Calculating single-sided gaskets with fins for transoms
(Technical settings > Group Gaskets > Gaskets wi th f ins )
The technical setting Gasket on one s ide has been renamed Gasket wi th f ins . Starting with this version, instead of a check box you will find a selection list with the following options:
a. Without gasket with fin
b. On all bolts
c. On top bolts only
d. On bottom bolts only
e. On inner bolts only
Existing items will remain unchanged. If in the previous versions you had ticked the check box for existing items, starting with this version the setting will be On al l bolts .
➔Technical settings, façades (aluminium)
Documentation Version 2019 R3
German October 2019
Page 24 of 25
JANIsoft 2019 R3
Page 24 of 25
7.3 Security systems (aluminium)
7.3.1 CE marking
CE marking in accordance with EN 16034
Starting with this version, the documents CE mark ing and Declarat ion of Per formance can be output for the following systems.
• Schüco ADS 80 FR 30
• Schüco ADS 80 FR 60
• Schüco AWS 60 FR 30 F30/EI30
• Schüco AWS 60 FR 30 G30/EW30
• Schüco AWS 70 FR 30 F30/EI30
• Schüco AWS 70 FR 30 G30/EW30
For these systems, the details already available for windows and doors relating to the product’s important characteristics have been supplemented by the characteristics specified in EN 16034 for windows and doors with fire and smoke protection properties:
• Fire resistance (for rooms with fire and/or smoke compartmentalisation)
• Smoke protection (only for applications in which the limitation of smoke spread is required)
• Self-closing (only for self-closing fire and/or smoke protection doors and/or windows)
• Capability for release
• Sustainability of capability for release
• Sustainability of self-closing with respect to quality loss
• Sustainability of self-closing with respect to ageing (corrosion)
You set these defaults for the respective systems in the system default settings or specifically in the item for each opening in the Field propert ies dialogue.
➔About CE marking (for windows/doors and façades)
7.3.2 Unit processing
Sample items in accordance with CE classification Fire-res. system in the project explorer
(Only with the material Fire and smoke res istant a luminium .)
Sample items are installed with the installation of the version 2019 R3. You can find these in the project explorer in the project list in the project CE Fire-res. system aluminium windows and doors .
Using the item descriptions, you can recognise the criteria fulfilled in the item with respect to the CE marking.
Via the Insert i tem from another pro ject function, you can simply copy over these items into your project.
1. Open the desired project in the project explorer.
2. In the Project l is t of contents , click on Inser t i tem f rom another pro ject . The Insert i tem from another pro ject dialogue opens.
3. There, select the items and click on the OK button to finish. The dialogue closes and the items are added to the project.
Documentation Version 2019 R3
German October 2019
Page 25 of 25
JANIsoft 2019 R3
Page 25 of 25
The surface finishes of the profiles are set to zero: mi l l f in ish and s i lver is set as the default fittings colour. The specific settings for the CE marking in the Field proper t ies dialogue are selected according to the criteria fulfilled in the sample item.
When using these items, please note:
Alterations to the sample items are not allowed. If changes are nevertheless made, these must be checked against the order and fabrication manual and conformity must be verified by you. Schüco will accept no warranty claims if the item is altered.
7.3.3 Forms
Declaration of conformity for fire protection barrier:
Schüco Firestop T90
(Since 2019 R2 SP01)
The form Schüco F irestop T90 has been updated.
➔“Declaration of conformity for fire protection barrier” dialogue
New: Installation confirmation in accordance with EN 16034
Starting with this version, it is possible to call up two new forms from the program.
• Installation confirmation, window in accordance with EN 16034 (German)
• Installation confirmation, door in accordance with EN 16034 (German)
Menu ribbon: Register General > Register Extras > Group Forms > Insta l la t ion conf i rmat ion in accordance wi th EN 16034 .
➔“Installation confirmation in accordance with EN 16034” dialogue
7.3.4 Sun shading
Schüco Integralmaster:
Changed maximum installable sizes (BFK 4-1 (10.2019))
The maximum installable sizes are checked in accordance with the sizes documented in the updated order manual.
➔About Schüco Integralmaster sun shading
Document author Nazmi Shtavica Created September 2019
File name Neuheiten_JANIsoft_2019_R2_EN.docx
Number of pages 29 © Software & Maschinen Services Public
New features
New features in JANIsoft 2019 R2
English
Documentation Version 2019 R2
English September 2019
Page 2 of 29
JANIsoft 2019 R2
Page 2 of 29
Jansen steel content
1 Programme changes ......................................................................................................................................... 4 1.1 Construction type, general ......................................................................................................................... 4
1.1.1 Calculation/quotation ..................................................................................................... 4 1.1.2 Order documents (Quotation ...): ................................................................................... 4 1.1.3 Glass spacers ................................................................................................................ 5 1.1.4 Output of lists ................................................................................................................. 5 1.1.5 CAD export .................................................................................................................... 6 1.1.6 Machine control (MCO) ................................................................................................. 7 1.1.7 Fabrication time calculation ........................................................................................... 7
1.2 Steel profiles .............................................................................................................................................. 8 1.3 New glazing bead button ........................................................................................................................... 8
2 New steel systems ........................................................................................................................................... 10 2.1 Jansen Art’15 ........................................................................................................................................... 10 2.2 Janisol Arte 66 ......................................................................................................................................... 11 2.3 VISS FIRE 50 roof glazing ....................................................................................................................... 12
3 Expansion Steel door systems ........................................................................................................................ 13 3.1 Door fitting manager ................................................................................................................................ 13
3.1.1 Entry of the hinge position as a free door hinge combination ..................................... 13 3.1.2 Optional additional calculation of the retaining catch unit and limiting stay (single-leaf)/(double-leaf) if Dorma/Boxer door closers have been selected .................................................................. 13
3.2 Economy 50 doors ................................................................................................................................... 14 3.3 Janisol HI doors ....................................................................................................................................... 15
3.3.1 Janisol HI RC door fittings (burglar resistant) .............................................................. 15 3.3.2 Janisol HI door optimisation ........................................................................................ 15
3.4 Janisol 2 E30, Janisol C4 EI60, Economy 60 E30/E60 ........................................................................... 16 4 Expansion Steel window systems ................................................................................................................... 17
4.1 Janisol Arte replacement of drainage profile ........................................................................................... 17 4.1.1 Standardisation of the Janisol Primo window to Janisol ............................................. 18
4.2 Economy 50 RC windows ........................................................................................................................ 19 4.2.1 Jansen Economy 50 RC window fittings ..................................................................... 19
5 Window and door systems aluminium ............................................................................................................. 20 5.1 Window/door systems (aluminium) that can no longer be delivered ....................................................... 20 5.2 Schüco VentoAir window rebate ventilator .............................................................................................. 20 5.3 Schüco AWS 60 BD ................................................................................................................................. 20 5.4 Schüco AWS/ADS 50.NI system ............................................................................................................. 20 5.5 Schüco AWS VV ventilation vent optimisations....................................................................................... 20 5.6 Unit processing ........................................................................................................................................ 21
5.6.1 Entrance door infill ....................................................................................................... 21 5.6.2 Cavity-fitted gearbox as a handle ................................................................................ 21 5.6.3 Technical settings ........................................................................................................ 21
6 Sliding units aluminium .................................................................................................................................... 22 6.1 Templates for 90-degree corners renamed ............................................................................................. 22 6.2 Schüco ASS 80 FD.HI ............................................................................................................................. 22 6.3 Schüco ASE 60/80.HI .............................................................................................................................. 23
Documentation Version 2019 R2
English September 2019
Page 3 of 29
JANIsoft 2019 R2
Page 3 of 29
7 Façades ........................................................................................................................................................... 24 7.1 Schüco AWS 114 and Schüco AWS 114.SI insert units ......................................................................... 24 7.2 System selection ...................................................................................................................................... 24
7.2.1 Façade systems summarised ...................................................................................... 24 7.2.2 Schüco TTC 50 ............................................................................................................ 25
8 Security systems .............................................................................................................................................. 26 8.1 Schüco TipTronic SimplySmart RWA ...................................................................................................... 26 8.2 Door fittings all series (BK 3-1 (06.2019)) ............................................................................................... 27
9 Sun shading ..................................................................................................................................................... 28 9.1 Schüco CSB in front of Schüco FWS 50/60 façades .............................................................................. 28 9.2 Integralmaster as a system solution ........................................................................................................ 28 9.3 Schüco sun shading ALB: ........................................................................................................................ 29
Documentation Version 2019 R2
English September 2019
Page 4 of 29
JANIsoft 2019 R2
Page 4 of 29
1 Programme changes
1.1 Construction type, general
1.1.1 Calculation/quotation
Users can enter VAT rates
Starting with this version, in addition to the standard VAT rate other VAT rates can be entered as well (this represents an expansion for international markets). This has resulted in the following changes:
• Entry of the VAT rate has been moved from the User set t ings dialog box to the VAT rates dialog box (menu ribbon: General tab > Sett ings tab > General group > VAT rates ).
Please note:
Entry of the VAT rate was user-specific in previous versions. Starting with this version, entry of the VAT is no longer user-specific and applies for the entire workspace. Following installation of the update, the VAT rate that appears will generally be the most recent VAT rate entered by the user who first started the programme.
• Additional VAT rates can be entered in the VAT rates dialog box with any name and a descriptive text.
a. If you only keep the standard VAT rate, this rate will automatically be displayed for all projects and items as before.
b. If you include other VAT rates in addition to the standard VAT rate, these rates can be allocated to the projects and items. A VAT rate can also be selected via the window Quick calculat ion .
The allocated VAT rates are included and displayed in the Calculat ion list and in the Order documents (Quotat ion . . . ) .
➢ VAT rates dialog box
Settings for Calculation in the Output opt ions dialog box
1.1.2 Order documents (Quotation ...):
Note regarding the transfer of a tax liability can be edited
If the VAT liability is to be transferred to the client, the net output is required. In the Document propert ies l is t in the Quotat ion . . . window under the Detai ls group, tick the Transfer tax l iab i l i ty check box. The VAT will not be shown in the order documents – with the exception of the delivery note. A note will appear at the end of the document obliging the customer to pay the VAT for the work performed. This text was fixed in previous versions.
Documentation Version 2019 R2
English September 2019
Page 5 of 29
JANIsoft 2019 R2
Page 5 of 29
Starting with this version, it will be possible to modify the text of the note, if necessary (menu ribbon: General tab > Sett ings tab > General group > VAT rates ).
➢ VAT rates dialog box
1.1.3 Glass spacers
New spacers
The following new spacers can be found in the selection list in the Glass and panel dialog box:
Spacers Material
Ensinger/Thermix TX.N pro Steel/plastic
Ensinger/Thermix Low Psi Aluminium/plastic
➢ Glass and panel dialog box (master data)
1.1.4 Output of lists
Order, bulk quantity list, quantity list, price enquiry for execution in EXC3: Setting for output of profiles, accessories
In the previous versions, in addition to the actual profiles (insulated, non-insulated and insulating bars) the setting Output > Prof i les in the Prof i le summary list also resulted in the output of articles that are calculated with a length (for example certain locking bars).
Starting with this version, such articles will be output with the setting Output > Accessor ies in the Accessory summary list.
As a result:
• With the setting Output > Prof i les , the Prof i le summary list will only include the profiles insulated, non-insulated and insulating bars.
• With the setting Output > Accessor ies , all other articles that do not have the profiles insulated, non-insulated and insulating bars are output in the Accessory summary . The list does not contain any articles that can be output optionally in other lists (e.g. ventilators, sun shading).
➢ Settings for Order in the Output opt ions dialog box
➢ Settings for Bulk quantity list in the Output opt ions dialog box
➢ Settings for Quantity list in the Output opt ions dialog box
➢ Settings for Enquiry for execution in EXC3 in the Output opt ions dialog box
Documentation Version 2019 R2
English September 2019
Page 6 of 29
JANIsoft 2019 R2
Page 6 of 29
1.1.5 CAD export
CAD export STEP file
(Optional additional function for the basic configuration level and up)
With this new function, the data for a unit (profiles, fillings) can be exported to a STEP file (ISO 10303 – Standard for the exchange of product model data).
➢ Export STEP file (universal 3D-file)
Documentation Version 2019 R2
English September 2019
Page 7 of 29
JANIsoft 2019 R2
Page 7 of 29
1.1.6 Machine control (MCO)
New functions in processing mode
Starting with this version, processing can easily be placed in the desired item of the profile with a mouse click.
The Move context menu function can also be used to move the position of the processing with a mouse click.
1.1.7 Fabrication time calculation
New triggers
New triggers for the calculation of fabrication time have been added. Use the filter function of the Inc luded s ince column in the Tr igger for fabr icat ion t ime calculat ion dialog box to see an overview of the triggers included in Version 2019 R2.
If you want to use the new triggers in your production lines, you must reallocate them to the corresponding activities and enter the time.
➢ Trigger for fabr icat ion t ime calculat ion dialog box
Documentation Version 2019 R2
English September 2019
Page 8 of 29
JANIsoft 2019 R2
Page 8 of 29
1.2 Steel profiles The following profiles have been removed for Economy 60 E30 and Economy 60 RS:
• 400.050
• 400.050GV
1.3 New glazing bead button Glazing bead button – 450.009 Steel open/Aluminium open – 450.025 for stainless steel glazing beads. New fixing knob with new PU quantity, checked based on the article with the packing unit.
The product corresponds to glazing bead buttons 450.007 and 450.008 and is loosely packed with 1,000 pieces per packing unit.
Documentation Version 2019 R2
English September 2019
Page 9 of 29
JANIsoft 2019 R2
Page 9 of 29
New control for the selection of the fixing heads, selection in settings (Technical/Processing). Delivery of glazing bead fixing head:
0 = loosely packed 1 = stacked (for fixing kit, 499.001 optimised)
Documentation Version 2019 R2
English September 2019
Page 10 of 29
JANIsoft 2019 R2
Page 10 of 29
2 New steel systems
2.1 Jansen Art’15 New Jansen profile system Jansen Art’15 with ServicePack 1 Outward-opening doors with opening types 0, 10, 11, 50, 51
The desired option can be selected in the Field propert ies under the Opening group in the Design field:
• flush-fitted
• face-fitted (single-leaf doors with or without fixed field)
• Rebated
For simple working with this system we recommend downloading the provided templates. You can download it HERE. You can then import the downloaded ZIP file in JANIsoft under “Import data” and use it as a template.
Documentation Version 2019 R2
English September 2019
Page 11 of 29
JANIsoft 2019 R2
Page 11 of 29
2.2 Janisol Arte 66 New window solution with 66mm deepness in the existing system Janisol Arte available with ServicePack 2 There are new tilt and turn windows in this system. The glazing settings can now be defined per field.
Documentation Version 2019 R2
English September 2019
Page 12 of 29
JANIsoft 2019 R2
Page 12 of 29
2.3 VISS FIRE 50 roof glazing
System Comment
VISS Fire 50 Roof glazing only
For VISS Fire 50 (roof glazing)
Starting with this version, the new VISS Fire 50 system can be selected for the following templates:
02: Façades:
01: Mullion –transom: Sloped modular façade
04: Skylight constructions
Mono-pitch roof Gable roof, symmetrical
4-sided pyramid
You define the desired fire resistance class in the unit parameters. The following classes are possible:
• RE30, REW30, REI30, RE45, REW45, REI45, RE60, REW60, REI60
Documentation Version 2019 R2
English September 2019
Page 13 of 29
JANIsoft 2019 R2
Page 13 of 29
3 Expansion Steel door systems
3.1 Door fitting manager
3.1.1 Entry of the hinge position as a free door hinge combination
A field with the position is included in the selection list Door hinge combination per hinge.
The user should now be able to change the hinge item directly in the field.
Note: Leaf top dimension and lower edge leaf / pedestal.
As soon as a standard value is changed, the message is displayed.
“The positioning of the door hinges has been changed. There is no check for compliance with the buildability according to system specifications.”
3.1.2 Optional additional calculation of the retaining catch unit and limiting stay (single-leaf)/(double-leaf) if Dorma/Boxer door closers have been selected
Default settings: without retaining catch, without limiting stay.
The articles are allocated to the slide rails as accessories and are generally calculated.
Documentation Version 2019 R2
English September 2019
Page 14 of 29
JANIsoft 2019 R2
Page 14 of 29
3.2 Economy 50 doors Multi-point locking systems for the full panic function:
– Multi-point locking systems 555.622–555.637 are calculated with all dependent articles.
– The catalogue has been expanded to include multi-point locking systems 555.622–555.637.
Documentation Version 2019 R2
English September 2019
Page 15 of 29
JANIsoft 2019 R2
Page 15 of 29
3.3 Janisol HI doors
3.3.1 Janisol HI RC door fittings (burglar resistant)
New RC fittings with the selection of a fitting identical to aluminium.
3.3.2 Janisol HI door optimisation
3.3.2.1.1 Sill profile 680.652Z replaces 680.650Z
Profile 680.652Z was entered in the programme as the initial selection and replaces profile 680.650Z (being discontinued).
Documentation Version 2019 R2
English September 2019
Page 16 of 29
JANIsoft 2019 R2
Page 16 of 29
3.4 Janisol 2 E30, Janisol C4 EI60, Economy 60 E30/E60
New double-vent solution (pendulum meeting rail) / market solution in UK
(only in England available, activation possible on request)
For single- and double-leaf doors (opening types 10, 11, 50, 51) and the Standard secur ity fitting type, in the Field propert ies dialog box (Prof i les group) in the Design selection list, there is a new entry called Lock s ide wi th pendulum meet ing r a i l .
Documentation Version 2019 R2
English September 2019
Page 17 of 29
JANIsoft 2019 R2
Page 17 of 29
4 Expansion Steel window systems
4.1 Janisol Arte replacement of drainage profile
Plastic profile replacement article
Description: for outward-opening windows, the plastic profile Article 452.981 is now a replacement for drainage profile 452.995 (with the exception of pivot window 452.995).
Construction with plug-in gasket, depth 60.
Variant: outward-opening.
Opening type:
1. 100 2. 101 3. 410 4. 411 5. 220 6. 221
Documentation Version 2019 R2
English September 2019
Page 18 of 29
JANIsoft 2019 R2
Page 18 of 29
4.1.1 Standardisation of the Janisol Primo window to Janisol
Starting with this version, the Janisol Pr imo system can no longer be selected to create new items.
Starting with this version, for the Janisol Pr imo system, items in the Janisol system can be selected if the material type in the item data is set to galvan ised .
Documentation Version 2019 R2
English September 2019
Page 19 of 29
JANIsoft 2019 R2
Page 19 of 29
4.2 Economy 50 RC windows
4.2.1 Jansen Economy 50 RC window fittings
Starting with this version, the new fittings in accordance with order information Jansen Economy 50 RC window will be calculated for windows in the Economy 50 system with security class WK1, WK2 (RC2) and WK3 (RC3).
Please note: The previous fitting calculation will only be continued for existing items that have been entered using the Economy 50 burglar -res istant system (through version 2018 R2).
Documentation Version 2019 R2
English September 2019
Page 20 of 29
JANIsoft 2019 R2
Page 20 of 29
5 Window and door systems aluminium
5.1 Window/door systems (aluminium) that can no longer be delivered The following systems have been removed from the Schüco product range and will no longer be offered for new items in the programme.
System
Schüco ADS 90.SI SimplySmart
5.2 Schüco VentoAir window rebate ventilator
Window systems depth 60 mm (BK 0-1 (06.2019):
Schüco AWS 90.SI+, Schüco AWS 90.SI+ Green, Schüco AWS 90 BS.SI+
Starting with this version, the Schüco VentoAir window rebate ventilator can also be recorded for windows with centre gaskets in systems with a depth of 90 mm. To do so, in the Field proper t ies dialog box, go to the Opening group and the VentoAir rebate fan property. Select the desired type there.
Add Schüco VentoAir rebate fan
5.3 Schüco AWS 60 BD
Conversion to Schüco SimplySmart window fittings
(System not available in all countries)
Starting with this version, the fitting types for the Schüco AvanTec SimplySmart and Schüco surface-mounted SimplySmart window fittings can be selected for new items. Existing items will remain unchanged.
5.4 Schüco AWS/ADS 50.NI system
Art. 157800 and 158380 coupling profiles
The profile sections with coupling profiles Art. 157800 and 158380 will no longer be offered for selection for unit couplings (article to be discontinued).
Please note: This change affects existing items for which these coupling profiles were used. They will no longer be calculated. If necessary, check the calculation results.
5.5 Schüco AWS VV ventilation vent optimisations The PU size will no longer be calculated for Article 276464 (RC case for FR locking component).
Documentation Version 2019 R2
English September 2019
Page 21 of 29
JANIsoft 2019 R2
Page 21 of 29
5.6 Unit processing
5.6.1 Entrance door infill
CAD export STEP file (door infill)
(Optional additional function for the basic configuration level and up)
Entrance door infill (triple panel) via the online configurator for door infill:
The door infill loaded in Schüco AD UP doors with vent profiles for mounted infill (one-sided and two-sided mechanical) can be exported in a STEP file (ISO 10303 – Standard for the exchange of product model data). The door infill is exported with the necessary processing.
Export STEP file (door infill)
5.6.2 Cavity-fitted gearbox as a handle
Security lock can be calculated differently for security classes > Basic
When selecting a cavity-fitted gearbox as a handle, starting with this version you define whether the security lock should be calculated or not in the Field proper t ies .
5.6.3 Technical settings
Rebate gasket for inside for face-fitted window vents: Corner edge protection Art. 224716
(Various window systems)
Starting with this version, corner edge protection Art. 224716 can be selected for standard thickness Art. 224310 for the property Rebate gasket for ins ide for face-f i t ted window vents (Gasket group).
Schüco AD UP 75, Schüco AD UP 90 and Schüco AWS 75 SI+/ADS 75.SI systems: Alternative glazing rebate insulation in accordance with the C2C standard
Starting with this version, the alternative glazing rebate insulation in C2C standard can be selected for the property Glazing var iant (U value opt imisat ion group).
Note: An activation code is required for Schüco AWS 75 SI. This code can be obtained from support.
Documentation Version 2019 R2
English September 2019
Page 22 of 29
JANIsoft 2019 R2
Page 22 of 29
6 Sliding units aluminium
6.1 Templates for 90-degree corners renamed (Schüco ASE 60/80.Hl (double-track only), Schüco ASS 39 PD.NI, Schüco ASS 77 PD.HI and Schüco ASS 77 PD.HI manual)
In order to distinguish them from the new templates for the ASE 67 PD system, the templates have been renamed. The calculation of the items remains unchanged.
Template Old name New name
Double- track 90-degree corner
Double- track 90-degree corner ( internal double vent)
Trip le- track 90-degree corner
Trip le- track 90-degree corner ( internal double vent)
6.2 Schüco ASS 80 FD.HI
Window fittings turn/tilt: Conversion to Schüco AvanTec SimplySmart
(Since 2019 SP02)
Types with a turn/tilt vent: Schüco AvanTec SimplySmart fittings are automatically calculated as the fittings.
Documentation Version 2019 R2
English September 2019
Page 23 of 29
JANIsoft 2019 R2
Page 23 of 29
6.3 Schüco ASE 60/80.HI
Spandrel safety barrier (French balcony)
1A.B 1A.B.2 1B.B
1C.B 1C.B.2
Starting with this version, spandrel safety barriers can be entered before the inward-facing movable vents of the single-track type (not level with the threshold, narrow interlock or TipTronic).
For suitable units, look in the Field proper t ies dialog box in the Spandrel safety barr ier group. If you select With spandrel safety barr ier , you can provide further information about the Spandrel safety barr ier .
Documentation Version 2019 R2
English September 2019
Page 24 of 29
JANIsoft 2019 R2
Page 24 of 29
7 Façades
7.1 Schüco AWS 114 and Schüco AWS 114.SI insert units
New automatic fittings “Outward-opening SimplySmart TipTronic”
For opening types 221: Projected top-hung window and 270: Paral le l -opening window , new fitting types can be selected in the TipTronic design.
• Basic – Outward-opening SimplySmart TipTronic
• RC2 – Outward-opening SimplySmart T ipTronic (only 221: Projected top-hung window)
For the fitting calculation, in the Field propert ies dialog box, define the conditions in accordance with the risk analysis in the order manual. Enter the necessary protective measures via Ins tal lat ion pos i t ion/access ib i l i ty (E1 or E2) and Use of bui ld ing/space (N1 to N3).
Please note: Only the new fitting type can be selected for new items. Existing items will remain unchanged.
7.2 System selection
7.2.1 Façade systems summarised
New group Aluminium façade
The Aluminium façade systems group has been abolished. Starting with this version, you will see the new Aluminium façade group in the overview of the systems and in the System templates and Select template dialog boxes.
Old groups New group
Aluminium mullion – transom façade
=> Aluminium façades Aluminium constructions
Aluminium structural glazing façades
Documentation Version 2019 R2
English September 2019
Page 25 of 29
JANIsoft 2019 R2
Page 25 of 29
7.2.2 Schüco TTC 50
Note: Schüco TTC 50 is a new solution and therefore may not be used with an old activation. A new activation code can be obtained from support.
The following restrictions and special features have been defined in the TTC 50 system:
1. Only module units are permitted, i.e. for TTC 50 only the Modular façade template can be selected and no skylight constructions are possible.
2. There is no variant in SG. 3. Insulation variants are available in SI, HI and standard. There is no single glazing. 4. Burglar resistance is not supported. 5. Old glass carriers on K1016538 will be replaced with follow-up articles. 6. Outer frame adapter 267408 is not supported. 7. With glazing rebate ventilation, the settings Total ventilation and Ventilation concept with gasket
fin are permitted. 8. The drainage level in a continuous transom can be set on the mullion via the function Modify
profile section detail.
Documentation Version 2019 R2
English September 2019
Page 26 of 29
JANIsoft 2019 R2
Page 26 of 29
8 Security systems
8.1 Schüco TipTronic SimplySmart RWA
Drives – changed article numbers
(Since 2019 SP01 and SP02)
Name Old drive type New drive
Dr. K50+ I 400 LS 291600 291661
Dr. K50+ I 400 RS 291601 291662
Dr. K50+ I 600 LS 291602 291663
Dr. K50+ I 600 RS 291603 291664
Dr. K50+ I 800 LS 291604 291665
Dr. K50+ I 800 RS 291605 291666
Dr. K50+ I 1000 RS 291606 291667
Dr. K50+ A 400 RS 291613 291669
Dr. K50+ A 600 RS 291614 291670
Dr. K50+ IZ 400 291607 291671
Dr. K50+ IZ 400 291608 291672
Dr. K50+ IZ 600 291609 291673
Dr. K50+ IZ 600 291610 291674
Dr. K50+ IZ 800 291611 291675
Dr. K50+ IZ 800 291612 291676
Dr. K50++ A 400 RS 291630 291669 (SP01)
Dr. K50++ A 600 RS 291632 291670 (SP01)
RWA closer LS ESR3 243591 276693
RWA closer RS ESR3 243592 276694
RWA closer LS ESR4 243595 276697
RWA closer RS ESR4 243596 276698
RWA closer RS ESR8 276148 276968
Documentation Version 2019 R2
English September 2019
Page 27 of 29
JANIsoft 2019 R2
Page 27 of 29
8.2 Door fittings all series (BK 3-1 (06.2019))
SafeMatic bolt locks and touch bars
(Schüco ADS 65.NI FR30, Schüco ADS 65.NI FR30, Schüco ADS 80 FR30, Schüco ADS 80 FR60, Firestop T90/F90, Schüco ADS 90 FR30, Schüco ADS 76.NI SP)
SafeMatic locks no longer have latch bolt monitoring.
In combination with a touch bar, use
• a lock contact switch (Art. 262626) instead of latch bolt monitoring for a single-leaf door.
• an InterLock lock in combination with a shoot bolt lock with a lock contact switch (Art. 279355/279349) for a double-leaf door.
The calculation has been modified in the programme.
Documentation Version 2019 R2
English September 2019
Page 28 of 29
JANIsoft 2019 R2
Page 28 of 29
9 Sun shading
9.1 Schüco CSB in front of Schüco FWS 50/60 façades Starting with this version, Schüco CSB sun shading can be used in front of Schüco FWS 50/60 façade systems.
About Schüco sun shading CSB
Note: An activation code is required for Integralmaster. This code can be obtained from support.
9.2 Integralmaster as a system solution
Update BFK 4-1
Note: Not available in all countries.
Starting with this version, the Integralmaster glare protection and sun shading integrated in the glazing beads will be calculated as a Schüco system solution. The calculation in the programme follows the updated order pages in the order and fabrication manual 4-1 (06.2019).
The entry options in the Field propert ies dialog box under the In tegralmaster sun shading group have been modified and expanded.
• The Colour of the suspens ion rod property has been renamed Colour of the guide rod .
• Operating type Manual : define the desired variant via the new property Chain type .
• Operating type Electr ic (not for fixed glazing): define the desired variant (separable, not separable) via the new property Cable l ink connector .
Changes upon price request/order:
• Starting with this version, a system article number is calculated for the inside blind. (Integralmaster motor = Art. 20030, Integralmaster chain = Art. 200301). At present, automatic pricing in the programme still cannot be implemented for this article. The price must be requested. To do so, use the list Pr ic ing request for Integralmaster sun shading .
• Germany: The processing variant must be provided for the pricing request/order (variant 1: SUN-MASTER; variant 2: customer). You must enter this information in the output options as a comment in the relevant list.
Please note: Existing items with Integralmaster sun shading are changing:
• In previous versions of the programme, there was no calculation for the standard glass support variant with an electric drive because this type of drive required special glass supports that were
Documentation Version 2019 R2
English September 2019
Page 29 of 29
JANIsoft 2019 R2
Page 29 of 29
included with the delivery. With the system change, these special glass supports are no longer needed for electric drives. Standard glass supports are calculated.
• In previous versions, the inside blind with electric drive moved from bottom to top. The new design moves from top to bottom like the manual variant.
• The semi-transparent fabric blinds and the darkened fabric blinds are no longer available for selection. For items from previous versions, the next possible blind from the selection list is used instead.
• Double vent correction: In previous versions, vent openings received the operating side on the side that was defined in the Field propert ies dialog box. Starting with this version, the operating side will be calculated inversely for the access leaf and the leaf. The operating side information in the Field proper t ies dialog box will be used for the access leaf. The slave leaf automatically receives the operating side on the other side (for example, view from inside: access leaf = operating side left, slave leaf = operating side right).
9.3 Schüco sun shading ALB:
Product range adjustment (BFK 4-2 (02.2019))
A number of article adjustments have been made to the ALB large louvre blade system because of optimisations to individual system components. ALB needle louvre blades and ALB glass louvre blades are no longer available in the system. Accessory components for these two systems will also be removed from the product range.
The calculation has been modified in the programme accordingly (CAL-40555: Implementation is still pending in part; glass louvre blades still pending).
For the Schüco ALB active linear drive system, needle louvre blades can no longer be selected for new items.