new products 2010 - toshiba · operation cooling heating air-flow direction top & bottom* top...
TRANSCRIPT
![Page 1: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/1.jpg)
![Page 2: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/2.jpg)
New Products 2010
![Page 3: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/3.jpg)
Super Daiseikai V [RAS-xxPKVP-E]
Super Daiseikai V [RAS-xxPKVP-E]
Super Daiseikai III [RAS-BxxSKVP-E]
Super Daiseikai III [RAS-BxxSKVP-E]
Daiseikai [RAS-xxSKVR-E]
Suzumi Plus [RAS-xxSKV2-E]
[RAS-BxxUFV-E]
Hybrid Inverter [RAS-xxSKV-E]
AvAnt [RAS-xx7SKV-E3]
Fix Speed H/P [RAS-xxSKHP-ES]
Fix Speed C/O [RAS-xxSKP-ES]
Fix Speed H/P [RAS-xxSKHP-ES(2)*]
*new OD size 13 + 24
RAS Single - Line Up 2009 2010
C O
P
(Siz
e 1
0)
5,3
5,1
4,2
3,7
3,6
![Page 4: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/4.jpg)
Super Daiseikai III C/O H/P [RAS-BxxSKVP-E]
[RAS-MxxSKCVP-E]
Super Daiseikai III H/P [RAS-BxxSKVP-E]
Hybrid Inverter C/O H/P [RAS-MxxSKCV-E]
[RAS-MxxSKV-E]
Suzumi C/O H/P [RAS-MxxSKCV-E]
[RAS-MxxSKV-E]
Duct C/O H/P [RAS-MxxGDCV-E]
[RAS-MxxGDV-E]
Duct C/O H/P [RAS-MxxGDCV-E]
[RAS-MxxGDV-E]
Compact Cassette C/O H/P [RAS-MxxSMUCV-E]
[RAS-MxxSMUV-E]
Compact Cassette C/O H/P [RAS-MxxSMUCV-E]
[RAS-MxxSMUV-E]
Console H/P [RAS-BxxUFV-E]
RAS Multi - Line Up Indoor
2009 2010
![Page 5: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/5.jpg)
Features:
• Bi-Flow Console
• For Single and Multi application
• Energy class A/A for 10/13k (Single)
• Energy class B/C for 18k (Single)
• COP 4,18/4,27 (size 10k at single application)
• Elegant design
• Floor heating feature with low air-flow
• Quiet operation for more comfort
• Efficient „IAQ“ filter system
• Single operation with Suzumi plus outdoor unit
• Multi operation with all multi outdoor units
Models: RAS-B10UFV-E (2,5/3,2kW) RAS-B13UFV-E (3,5/4,2kW) RAS-B18UFV-E (5,0/5,8kW)
RAS Single/Multi – Console
![Page 6: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/6.jpg)
3 comfort features: Bi-flow, supreme heating mode and smart user interface
Smart user interface
Floor warming mode
• Pureflow filter • One touch my comfort • Hi-power mode • Eco-logic mode • Comfort sleep • Timer
Bi-flow
Elegant and simple design
RAS Console
Features
![Page 7: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/7.jpg)
Operation Cooling Heating
Air-flow direction
Top & Bottom* Top Top & Bottom Top Bottom
The two outlet at the top and bottom ensure a comfortable air conditioning. You can choose the best air outlet from the following patterns. Especially, the warm air from the bottom is TOSHIBA`s original feature and it flows directly to the floor and spreads along the floor.
Bi-flow
* In case of cooling operation with upper and lower flow, lower flow stops automatically when it reaches the setting temperature.
RAS Console - Features
only
![Page 8: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/8.jpg)
RAS-B10UFV-E
RAS-B13UFV-E
RAS-B18UFV-E
RAS-10SAV2-E
RAS-13SAV2-E
RAS-18SAV2-E
Single combination
(Suzumi Plus outdoor unit)
RAS-M14GAV-E RAS-M18GAV-E
RAS-4M23SAV-E RAS-3M26GAV-E1 RAS-4M27GAV-E1
RAS-5M34UAV-E
RAS-3M18SAV-E
RAS Console
Combinations
Multi combination
(Inverter multi outdoor unit)
![Page 9: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/9.jpg)
RAS 5 room multi outdoor unit
![Page 10: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/10.jpg)
Merkmale:
• DC Hybrid Inverter
High Energy Saving Control High Power Factor Control • DC Twin Rotary Compressor Low Noise & Low Vibration Energy Saving (Low Revolution) High Reliability (Low Load to Shaft) • World´s best class heating capacity & COP 4,24 • Wide selection of indoor units (Hi-wall, Console, 4-way cassette and duct)
Model: RAS-5M34UAV-E (10/12kW)
RAS Multi – 5-room outdoor unit
![Page 11: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/11.jpg)
Capacity (kW) Cooling 10,0 (3,7 to 11,0)
Heating 12,0 (3,4 to 14,0)
Power consumption (kW) Cooling 2,923
Heating 2,833
Dimension (mm)
Height 890
Width 900
Depth 320
EER 3,42
COP 4,24
Sound pressure (dB) Cooling 51
Heating 54
Total piping length (m) 80
Height difference (m) 15
Outdoor temperature range (℃) Cooling
Heating
10 to 43
-10 to 22
RAS Multi – 5-room outdoor unit
Specification
RAS-5M34UAV-E
Weight : 75 kg
890
320
900
![Page 12: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/12.jpg)
Super DAISEIKAI
Suzumi
Console
Duct
Compact 4-way
Cassette (60x60)
RAS Multi – 5-room outdoor unit
Highest flexibility
![Page 13: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/13.jpg)
Features:
• High-static pressure duct unit for single use
• Combination with Digital Inverter BIG
• Chassis equal to S-MMS indoor unit
• Industrial No. 1 COP (3,45/3,31)
• External static pressure of up to 196Pa
• 3 steps switchable static pressure
68,6 / 137 / 196 Pa
Models: RAV-SM2242DT-E (20,0/22,4kW) RAV-SM2802DT-E (23,0/27,0kW)
RAV – High Static Duct
Available July 2010 / week 28
![Page 14: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/14.jpg)
Outdoor unit Power supply 3N~380-415V / 50Hz Maximum current 8HP:18A / 10HP:22A
Indoor unit Power supply 1φ220-240V / 50Hz Maximum current 8HP&10HP:15A
RAV – High Static Duct
Electrical Wiring
![Page 15: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/15.jpg)
Parts name Model name Notes Remarks
Drain pump kit TCB-DP32DE Stand-up about 320mm or less
Filter chamber TCB-FCY100DE For long-life filter and high-efficiency
filter
Long-life pre-filter TCB-PF3DE Dust collecting effect : 50% Use with TCB-FCY100DE
High-efficiency filter 65 TCB-UFM3DE Dust collecting effect : 65% Use with TCB-FCY100DE
High-efficiency filter 90 TCB-UFM7DE Dust collecting effect : 90% Use with TCB-FCY100DE
TCC-link adapter TCB-PCNT30TLE2 1:1 model connection interface
RAV – High Static Duct
Indoor accessories
![Page 16: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/16.jpg)
Features:
• Power supply 400V 3phase
• Nr.1 EER/COP
• Additional outdoor unit (14/16kW) for 1:1 with 4-way-cassette, or Twin/Triple- application
• Extended capacities
SP1404: 2,6 - 14 kW cooling cap.
SP1404: 2,4 - 16,5 kW heating cap.
• Extended operation range
cooling: -15 – 46°C
Models: RAV-SP1104AT8-E (10,0/11,2kW) RAV-SP1404AT8-E (12,5/14,0kW) RAV-SP1604AT8-E (14,0/16,0kW)
RAV – Super Digital Inverter Outdoor units 3ph
Available Aug. 2010 /
Week 32
![Page 17: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/17.jpg)
Window Switch & On/Off
TCB-IFCB5-PE
Application control PC Board for RAV and VRF indoor units providing 2 different control functions:
• Window Switch
• Remote On/Off
With using a (local supplied) window switch the unit operation is turned off after opening the window (contact) and not operate again until the window is closed again
After closing:
• Standard function, indoor unit remains off
• Return function, indoor unit will revert to the last setting before the window was opened.
Controller for single indoor unit or a group of up to 8 indoor units (when connected to the master unit of that group)
![Page 18: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/18.jpg)
Preview 2011
Console unit for VRF 2,2 / 2,8 / 3,6 / 4,6 / 5,6 kW For S-MMS, S-HRM, MiNI-SMMS Plan vor January 2011
Console unit for LC 4,0 / 5,0 kW Combination with DI and S-DI Plan vor May 2011
2-Way cassette unit for VRF 2,2 – 16,0 kW New chassis type (290 mm height) Plan vor Q1 2011
![Page 19: New Products 2010 - Toshiba · Operation Cooling Heating Air-flow direction Top & Bottom* Top Top & Bottom Top Bottom The two outlet at the top and bottom ensure a comfortable air](https://reader030.vdocument.in/reader030/viewer/2022041213/5e02f3acd9e2ea2f20410eb5/html5/thumbnails/19.jpg)
Thank you for your attention !