Eureka project
NewvoiceImproved rehabilitation of
laryngectomised patients
G.J. VerkerkeUniversity Medical Center Groningen
The Netherlands
![Page 2: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/2.jpg)
Thebe, 18e dynasty(1400 BC)
Nowadaysmedical problemsare still often solved bytechnical solutions.This requires a multidisciplinary approachin which MD’s and engineers co-operate.
![Page 3: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/3.jpg)
Dept of Biomedical Engineering,
University Medical Center Groningen, NL
GJ Verkerke (project leader), HK Schutte, G Rakhorst,
HC van der Mei, TG van Kooten, EB van der Houwen,
MBM van Leeuwen, MJ Gibcus, AJ Knol, J Tack
VU medical center, Amsterdam, NL
HF Mahieu, JM Festen, IM Verdonck, CDL van Gogh
University Medical Centre St. Radboud, Nijmegen, NL
HAM Marres, JA Jansen
University Hospital Groningen, Groningen, NL
FWJ Albers, BFAM van der Laan
University Hospital Dijkzigt Rotterdam, Rotterdam, NL
CA Meeuwis
Intravasc.nl, Groningen, NL
JP van Loon, EJO ten Hallers
Medin Instruments, Groningen, NL
H Leever, A de Jong
SASA, Thesinge, NL
HJ Busscher
Eureka project NewvoiceParticipants
Katharinen Hospital, ENT-department, Stuttgart, D
R HagenAdeva Medical GmbH, Lübeck, D
J GrundeiUniversity of Wales, Cardiff, UK
M WatersPrincipality Ltd, Newport, UK
L Basil
Medical Healthcom s.r.o., Prague, CZ
F ŠramEuropean Hospital, ENT-department, Rome, I
IF HerrmannUniversity of Padova, ENT-department, Padova, I
A StaffieriUniversidad del Pais Vasco, San Sebastian, SP
J Algaba
![Page 4: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/4.jpg)
After laryngectomy
tracheostoma valve
+ HME-filter
![Page 5: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/5.jpg)
Drawbacks
• Voice quality
• Fixation of TSV, HME-filter
• Fixation of shunt valve
• Biofilm formation
![Page 6: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/6.jpg)
Goal of the project
Voice-producing shunt prosthesis
• Shunt valve
• Biofilm-resistant material
• Voice-producing element
• Fixation method for shunt,
TSV-valve,HME-filter
• Integration
• Clinical testing
![Page 7: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/7.jpg)
Biofilm adhesion
![Page 8: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/8.jpg)
Applied coatings
1 C16H19F17O3Si
2 C8H4Cl3F13Si
3 C14H19F13O3Si
4 C10H4Cl3F17Si
5 C20H10F33ClSi
6 C36H76O4Si
7 C7H16O2Si3
8 C3H4Cl3F3Si
A C10H4Cl3F17Si
B C8H18O5Si
PEO chains in water
20 nmglass substrata
1.5
nm
0.2 nm
Supersmooth mold
![Page 9: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/9.jpg)
In-vitro test set-up
1. Grafting of shunt valves2. Biofilm-formation3. Flushing with PBS4. Flushing with medium5. After 8 days
determination of bacteria and yeasts
phosphatebufferedsaline
growthmedium
pump
shunt valve
artificial throat
![Page 10: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/10.jpg)
Micro-organisms
• Candida albicans GBJ 13/4a• Candida tropicalis GB 9/9• Staphylococcus aureus GB 1/2• Staphylococcus epidermidis GB 9/6• Streptococcus salivarius GB 24/9• Rothia dentocariosa GB 52/52b
![Page 11: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/11.jpg)
In-vitro results
0%
20%
40%
60%
80%
100%
120%
140%
coating
% c
olo
ny
fo
rm
ing
un
its
controle
coating 5
coating 6
coating 7
coating 8
coating A
coating B
= Bacteria
= Yeasts
![Page 12: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/12.jpg)
Glass side Brush side
In-vitro results
![Page 13: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/13.jpg)
Advancing water contact angles:
Silicone rubber 115 degrees
Argon plasma treated 15 degrees
After six weeks in vivo
In-vivo results
![Page 14: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/14.jpg)
Goal of the project
Voice-producing shunt prosthesis
• Biofilm-resistant material
• Voice-producing element
• Fixation method for shunt, TSV-valve,HME-filter
• Shunt valve
• Integration
• Clinical testing
![Page 15: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/15.jpg)
Requirements
• Geometry: in shunt valve• Sound
– fundamental frequency: 110 Hz ♂, 210 Hz ♀– SPL: 65 dB - 80 dB at 30 cm – Frequency-variation: +18%, -6%
• Energy source: 0.4 - 1.5 kPa, 180 - 320 ml/s• Power spectrum: decay of 10-12 dB/octave• Reliability
![Page 16: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/16.jpg)
Membrane principle
![Page 17: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/17.jpg)
Numerical simulation
![Page 18: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/18.jpg)
![Page 19: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/19.jpg)
Lung model
![Page 20: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/20.jpg)
In-vitro results
F0 vs. P, for h0l3
0
20
40
60
80
100
120
140
0,00 0,50 1,00 1,50 2,00
P (kPa)
F0 (Hz)
h0l3I
h0l3II
h0l3III
Linear (h0l3I)
Linear (h0l3II)
Linear (h0l3III)
JW Tack, Annals Biomed Eng, 2006
![Page 21: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/21.jpg)
In-vitro results
JW Tack, Head Neck, 2007 (in press)
![Page 22: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/22.jpg)
In-vivo results
![Page 23: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/23.jpg)
Goal of the project
Voice-producing shunt prosthesis
• Biofilm-resistant material
• Voice-producing element
• Fixation method for shunt, TSV-valve,HME-filter
• Shunt valve
• Integration
• Clinical testing
![Page 24: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/24.jpg)
Voice rehabilitation after total laryngectomy:
Background
• Shunt valve
• Tracheostoma valve & Heat and Moisture Exchange (HME) filter
Fixation problems:
• Discrepancies between shunt valve and TE fistula
• Difficulties in long-term attachment of tracheostoma valve and/or HME filter to the peri-stomal skin
ten Hallers EJO, Acta Otolaryngol, 2005
![Page 25: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/25.jpg)
• Ring: CP Titanium grade 2
• Stop: Silicon rubber
• Mesh:
– Knitted monofilament polypropylene(Bard® Marlex®)
– Or titanium, 50 micron thick sintered fibers, porosity 80%, 500g/m2. (Bekaert)
Design: E.B. van der Houwen
Tracheo-EsophagealTissue Connector
or
![Page 26: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/26.jpg)
• Ring:
– CP Titanium grade 2
– or silicon elastomer (MED-6033, NuSil)
with titanium inserts that function as a
base plate for screws.
• Mesh:
– Knitted monofilament polypropylene
(Bard® Marlex®) mesh
• Screws:
• 4 phase-1 small screws (subcutaneous)
– 4 phase-2 longer screws (percutaneous)
Tracheostoma Tissue Connector
Design: E.B. van der Houwen
3.0 cm
![Page 27: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/27.jpg)
Animal experiments
Sagital section of goat head & neck with tracheostomy and
Tissue Connectors implanted
ten Hallers EJO, Biomaterials, 2004
![Page 28: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/28.jpg)
Sterile conditions, general anesthesia
Median incision Trachea separationand resection
ImplantationTissue Glue
Closing after implantation
End of procedure X-rays
Methods, Materials and AnimalsSurgical Procedure
![Page 29: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/29.jpg)
ResultsMacroscopyGeneral:
- Wide range in geometry of trachea
- 100% survival of surgical procedure
- Several complications due to tracheostomy
• Pneumonia and lung edema
• Airway obstruction with mucus
• Pressure necrosis caused by canula
Tracheostoma TC
- Week 0-6 mild inflammatory
reactions
- Week 7-12 also infections
Tracheo-Esophageal TC
- Firm implant fixation
- Pilot study: Tracheal punction technical
feasible
ten Hallers EJO, Laboratory Animals, 2006.
![Page 30: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/30.jpg)
ResultsMacroscopy
9 weeks
5 weeksLateral X-ray
Post-mortem Embedded in resin
![Page 31: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/31.jpg)
ResultsMicroscopy
- Volume increase of silicone rubber after chemical reaction withmethylmetacrylate (MMA)
- Difficult to determine tissue adhesion due to artefacts
- Sufficient fibrous tissue reaction for firm fixation
Tracheo-Esophageal TC
Silicone
rubberTi
CapsulePP Mesh
Glue
ten Hallers EJO, Head Neck, 2006
![Page 32: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/32.jpg)
ResultsMicroscopy
AA`
Prototype 1 Prototype 2
Tracheostoma TC
Silicone rubber
Ti insert
- Profound epithelial downgrowth up tonear complete marsupialization
- Persisting infections
ten Hallers EJO, J Biomed Mater Res A, 2007
![Page 33: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/33.jpg)
Conclusions
Tracheo-Esophageal TC:
• Successful firm implant fixation
• Further tests are needed with separate tracheal and esophageal punction to determine its feasibility
Tracheostoma TC:
• Not a feasible concept in this animal model
• Insufficient tissue stabilization results in classic percutaneous implant failure, sooner or later
This tracheostomy animal model is suitable for short-term tests only with intensive care
![Page 34: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/34.jpg)
Future work
![Page 35: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/35.jpg)
Future work
![Page 36: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/36.jpg)
Future work
1
EB van der Houwen
![Page 37: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/37.jpg)
Future work
EB van der Houwen
![Page 38: Newvoice - rug.nl · JP van Loon, EJO ten Hallers Medin Instruments, Groningen, NL H Leever, A de Jong SASA, Thesinge, NL HJ Busscher Eureka project Newvoice Participants Katharinen](https://reader036.vdocument.in/reader036/viewer/2022062605/5fc875254579351f1a7748d2/html5/thumbnails/38.jpg)
Eureka project Newvoice