IMPLEMENTATIONGENERAL NOTES
INDEX OF SHEETS
NORTHEAST EXTREME TEE BEAM (NEXT) USAGE NOTES
- SPEED OF SET
- STRENGTH OF CONCRETE IN CLOSURE POURS
- FINAL STRENGTH
- RELEASE STRENGTH
SPECIFY THE REQUIRED CONCRETE STRENGTHS:
FOR INTEGRAL ABUTMENTS, ETC.
FOR BEAM ENDS FOR CONTINUITY OF LIVE LOAD, SPECIAL DETAILS
GEOMETRIC END TREATMENTS, EXTENSIONS OF PRESTRESSING STRAND
CREATE SPECIAL BEAM END DETAILS AS NEEDED, SUCH AS VARYING
- DECK OVERHANG AND BARRIER REINFORCING
- BEAM END REINFORCING
- SIZE AND SPACING OF SHEAR REINFORCING
DECKS ASSUMING THAT THE BEAM WEB IS A BEAM LINE.
SPECIFICATIONS. USE THE SAME METHODS AS CAST-IN-PLACE
POURS ACCORDING TO THE AASHTO LRFD BRIDGE DESIGN
- CHECK DECK REINFORCING IN THE TOP FLANGE AND THE CLOSURE
- NUMBER OF STRAIGHT STRAND AND LAYOUT
INCLUDING:
DESIGN THE BEAM ACCORDING TO THE REQUIREMNETS OF THE OWNER,
IT IS THE DESIGNER'S RESPONSIBILITY TO:
MAXIMUM RECOMMENDED SKEW ANGLE: 20 DEGREES
- PROVIDES ADDITIONAL DECK PROTECTION
- ACCOUNTS FOR TOP FLANGE DIFFERENTIAL
- ELIMINATES THE NEED FOR DECK GRINDING
FOLLOWING REASONS:
DECK OVERLAYS COMBINED WITH WATERPROOFING MEMBRANES ARE RECOMMENDED FOR THE
THICKNESS FOR BEAM WEIGHT.
OF •" OF TOP FLANGE IN THE SECTION PROPERTIES, HOWEVER INCLUDE FULL DECK
LONGITUDINAL JOINTS MAY BE USED. TO ACCOUNT FOR THIS IN DESIGN, ASSUME LOSS
A •" CONCRETE GRINDING ALLOWANCE FOR CORRECTING UNEVEN ROADWAY SURFACES AT
PRESTRESSING STRAND: LOW RELAXATION STRAND, 0.6" DIAMETER, AASHTO M 203 GRADE 270
REINFORCING STEEL: fy = 60,000 PSI (COATING AS PER °AGENCY STANDARDS)
USE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS EXCEPT AS NOTED OTHERWISE
LIVE LOAD DISTRIBUTION FACTOR CALCULATIONS
g
g s
s NEXT F
NEXT E
NEXT D
NE
XT B
EA
M - G
EN
ER
AL N
OTES
AN
D
US
AG
E
NEXT BEAM MISCELLANEOUS DETAILSNEXT-14
NEXT D BEAM - SUBSTRUCTURE DETAILSNEXT-13
NEXT E BEAM - SUBSTRUCTURE DETAILSNEXT-12
NEXT F BEAM - SUBSTRUCTURE DETAILSNEXT-11
NEXT D BEAM - DECK DETAILSNEXT-10
NEXT E BEAM - DECK DETAILSNEXT-09
NEXT F BEAM - DECK DETAILSNEXT-08
NEXT BEAM - TYPICAL BRIDGE SECTIONSNEXT-07
NEXT BEAM - SECTION PROPERTIESNEXT-06
NEXT BEAM - TYPICAL BEAM REINFORCINGNEXT-05
NEXT D - PROFILE ACCOMMODATION DETAILSNEXT-04
NEXT E - PROFILE ACCOMMODATION DETAILSNEXT-03
NEXT F - PROFILE ACCOMMODATION DETAILSNEXT-02
GENERAL NOTES AND USAGENEXT-01
BEAM
- APPLY THE COMBINED DISTRIBUTION FACTOR FOR THE DESIGN OF THE ENTIRE NEXT D
- COMBINE (ADD) THE TWO DISTRIBUTION FACTORS FOR EACH STEM TOGETHER
- THE APPLICATION OF THE LEVER RULE FOR EXTERIOR STEMS SHALL APPLY
ARTICLE 4.6.2.2.2.
- CALCULATE THE DISTRIBUTION FACTORS FOR EACH STEM USING THE TABLES IN
- USE THE AVERAGE STEM SPACING FOR THE BEAM SPACING TERM IN THE EQUATIONS
- SEE ADJACENT DETAIL FOR CALCULATION OF e AND t
OF TOP FLANGE TO THE TOP OF THE DECK)
- ASSUME THAT THE FLANGE PORTION OF THE BEAM IS THE COMPOSITE DECK (BOTTOM
UNDERSIDE OF THE TOP FLANGE)
- ASSUME THAT THE STEM PORTION OF THE BEAM IS THE STRINGER (UP TO THE
PROPERTIES USED FOR CALCULATION OF I AND A)
- TREAT EACH STEM AS AN INDIVIDUAL STRINGER (HALF OF TOTAL BEAM SECTION
THE DECK IS SUFFICIENTLY CONNECTED TO ACT AS A UNIT
- USE AASHTO CROSS SECTION I (ARTICLE 4.6.2.2.1 AND 4.6.2.2.2) ASSUMING THAT
NEXT D BEAMS:
BEAM
- APPLY THE COMBINED DISTRIBUTION FACTOR FOR THE DESIGN OF THE ENTIRE NEXT F
- COMBINE (ADD) THE TWO DISTRIBUTION FACTORS FOR EACH STEM TOGETHER
- THE APPLICATION OF THE LEVER RULE FOR EXTERIOR STEMS SHALL APPLY
ARTICLE 4.6.2.2.2.
- CALCULATE THE DISTRIBUTION FACTORS FOR EACH STEM USING THE TABLES IN
- USE THE AVERAGE STEM SPACING FOR THE BEAM SPACING TERM IN THE EQUATIONS
- SEE ADJACENT DETAIL FOR CALCULATION OF e AND t
PROPERTIES USED FOR CALCULATION OF I AND A)
- TREAT EACH STEM AS AN INDIVIDUAL STRINGER (HALF OF TOTAL BEAM SECTION
- USE AASHTO CROSS SECTION K (ARTICLE 4.6.2.2.2)
NEXT F AND E BEAMS:
33 3
312 / 2
017
AD
DE
D
NO
TES
AN
D IN
DE
X
RE
VISIO
NS
DES
CRIP
TIO
ND
ATE
NO.
SH
EET:
TM
PCI
DIS
CLAIM
ER:
PR
EC
AST/P
RESTR
ESSE
D
CO
NC
RETE IN
STIT
UTE
NO
RT
HE
AST
WW
W.P
CIN
E.O
RG
NO
RT
HE
AST E
XTR
EM
E TEE (N
EXT)
BE
AM
DET
AIL
S
thro
ugh this guidelin
e. If such services are re
quired, please seek an appro
priate professio
nal.
Northeast is supplying inform
ation only. P
CI Northeast is not re
ndering engineering or other professio
nal s
ervices
or da
mages arising out of this inform
ation. P
CI Northeast has publis
hed this work with the understa
nding that P
CI
sources belie
ved to be relia
ble. P
CI Northeast or its me
mbers
hips shall not be responsible for any errors, o
missio
n
The details sho
wn are guidelin
es and should not be considere
d sta
ndards. T
he inform
ation has been obtained fro
m
ISS
UE
DATE: 03 / 10 / 15
WEARING SURFACE
WEARING SURFACE
WEARING SURFACE
REINFORCED CIP CONCRETE DECK
8" MINIMUM
REINFORCED CIP CONCRETE DECK
4•" MINIMUM
4" TOP FLANGE
INTEGRAL DECK/TOP FLANGE8" MINIMUM
NEXT D BEAMS
NEXT F BEAMS
NEXT E BEAMSTOP FLANGE4" INTEGRAL PARTIAL DECK/
g
e
ts
IN eg CALCULATION
NEGLECT THIS PORTION OF DECK
g
e
ts
TREAT STEM AS THE "BEAM"
TREAT STEM AND TOP FLANGE AS THE "BEAM"
TREAT TOPPING AS THE "DECK"
g
e
ts
TREAT STEM AND TOP FLANGE AS THE "BEAM"
TREAT TOPPING AS THE "DECK"
TREAT TOP FLANGE AS THE "DECK"
NE
XT F - P
RO
FIL
E
AC
CO
MM
OD
ATIO
N
DET
AIL
S
NOTES
NE
XT 02
10 / 2
015
1C
HA
NG
ED
RAILIN
G
TO
CO
NC
RETE
BA
RRIE
R
1
1
1
GUIDE.
CAMBER, SEE PCI NORTHEAST PROFILE AND CAMBER MANAGEMENT
6. FOR MORE INFORMATION ON ACCOMMODATION OF PROFILES AND
SHOULD BE BASED ON THE ESTIMATED CAMBER AT ERECTION.
5. THE ESTIMATED CAMBER USED FOR THE VARIABLES NOTED ABOVE
THICKNESS TOPPING IN THE DESIGN OF THE BEAM.
4. THE ENGINEER SHOULD ACCOUNT FOR THE ESTIMATED VARIABLE
TO THE HEIGHT OF THE CURB OR BARRIER.
ADJUST THE TOPPING THICKNESS AS REQUIRED. THE SAME APPLIES
REQUIRING SURVEY OF THE BEAMS AFTER ERECTION, AND THEN
THE ESTIMATED CAMBER. THE PLANS SHOULD INCLUDE NOTES
THICKNESS OF THE TOPPING OR OVERLAY ON THE PLANS BASED ON
3. THE ENGINEER SHOULD DETAIL THE ANTICIPATED VARIABLE
DETAILS.
ORDINATE, THE DETAILS WILL BE SIMILAR TO THE TANGENT PROFILE
2. CREST VERTICAL CURVES: IF THE CAMBER IS LESS THAN THE CURVE
NOTE THAT THE HEIGHT OF THE CURB OR PARAPET WILL STILL VARY.
TOPPING. ANOTHER OPTION IS TO VERY THE THICKNESS OF THE OVERLAY.
1. THE DETAILS SHOWN DEPICT VARYING THE THICKNESS OF THE CONCRETE
RE
VISIO
NS
DES
CRIP
TIO
ND
ATE
NO.
SH
EET:
TM
PCI
DIS
CLAIM
ER:
PR
EC
AST/P
RESTR
ESSE
D
CO
NC
RETE IN
STIT
UTE
NO
RT
HE
AST
WW
W.P
CIN
E.O
RG
NO
RT
HE
AST E
XTR
EM
E TEE (N
EXT)
BE
AM
DET
AIL
S
thro
ugh this guidelin
e. If such services are re
quired, please seek an appro
priate professio
nal.
Northeast is supplying inform
ation only. P
CI Northeast is not re
ndering engineering or other professio
nal s
ervices
or da
mages arising out of this inform
ation. P
CI Northeast has publis
hed this work with the understa
nding that P
CI
sources belie
ved to be relia
ble. P
CI Northeast or its me
mbers
hips shall not be responsible for any errors, o
missio
n
The details sho
wn are guidelin
es and should not be considere
d sta
ndards. T
he inform
ation has been obtained fro
m
ISS
UE
DATE: 03 / 10 / 15
CONSTANT HEIGHT CURB/BARRIER
CONSTANT THICKNESS OVERLAY
THICKNESS VARIES
CURB/BARRIER HEIGHT VARIES
OVERLAY THICKNESS VARIES
NEXT F BEAMS
NEXT F BEAMS - TANGENT PROFILE
NEXT F BEAMS - CREST VERTICAL CURVE PROFILE
NEXT F BEAMS - SAG VERTICAL CURVE PROFILE
OPTION 2: VARY OVERLAY THICKESS
OPTION 1: VARY TOPPING THICKESS
WEARING SURFACE
4" TOP FLANGE
CAUSED BY BEAM CAMBERTHICKER TOPPING THICKNESS AT ENDS
PLUS BEAM CAMBERCAUSED BY VERTICAL CURVE ORDINATETHICKER TOPPING THICKNESS AT ENDS
TOPPINGCONSTANT THICKNESS
MINIMUM TOPPING THICKNESS AT MID-SPAN
MINIMUM TOPPING THICKNESS IF CAMBER IS LESS THAN ORDINATECURVE ORDINATE IS LARGER THAN CAMBERTHICKER TOPPING THICKNESS AT MID-SPAN IF VERTICAL
THICKER TOPPING IF CAMBER IS LESS THAN ORDINATECURVE ORDINATE IS LARGER THAN CAMBERMINIMUM TOPPING THICKNESS AT ENDS IF VERTICAL
MINIMUM TOPPING THICKNESS AT MID-SPAN
FOR TYPICAL BEAM BRIDGESMINIMUM THICKNESS AS PER STATE STANDARDSREINFORCED CIP CONCRETE DECK
NE
XT E - P
RO
FIL
E
AC
CO
MM
OD
ATIO
N
DET
AIL
S
NOTES
NE
XT 03
CH
AN
GE
D
RAILIN
G
TO
CO
NC
RETE
BA
RRIE
R10 / 2
015
1
1
1
1
GUIDE.
CAMBER, SEE PCI NORTHEAST PROFILE AND CAMBER MANAGEMENT
6. FOR MORE INFORMATION ON ACCOMMODATION OF PROFILES AND
SHOULD BE BASED ON THE ESTIMATED CAMBER AT ERECTION.
5. THE ESTIMATED CAMBER USED FOR THE VARIABLES NOTED ABOVE
THICKNESS TOPPING IN THE DESIGN OF THE BEAM.
4. THE ENGINEER SHOULD ACCOUNT FOR THE ESTIMATED VARIABLE
TO THE HEIGHT OF THE CURB OR BARRIER.
ADJUSTMENT OF THE TOPPING THICKNESS AS REQUIRED. THE SAME APPLIES
REQUIRING SURVEY OF THE BEAMS AFTER ERECTION, AND THEN
THE ESTIMATED CAMBER. THE PLANS SHOULD INCLUDE NOTES
THICKNESS OF THE TOPPING OR OVERLAY ON THE PLANS BASED ON
3. THE ENGINEER SHOULD DETAIL THE ANTICIPATED VARIABLE
DETAILS.
ORDINATE, THE DETAILS WILL BE SIMILAR TO THE TANGENT PROFILE
2. CREST VERTICAL CURVES: IF THE CAMBER IS LESS THAN THE CURVE
NOTE THAT THE HEIGHT OF THE CURB OR PARAPET WILL STILL VARY.
TOPPING. ANOTHER OPTION IS TO VERY THE THICKNESS OF THE OVERLAY.
1. THE DETAILS SHOWN DEPICT VARYING THE THICKNESS OF THE CONCRETE
RE
VISIO
NS
DES
CRIP
TIO
ND
ATE
NO.
SH
EET:
TM
PCI
DIS
CLAIM
ER:
PR
EC
AST/P
RESTR
ESSE
D
CO
NC
RETE IN
STIT
UTE
NO
RT
HE
AST
WW
W.P
CIN
E.O
RG
NO
RT
HE
AST E
XTR
EM
E TEE (N
EXT)
BE
AM
DET
AIL
S
thro
ugh this guidelin
e. If such services are re
quired, please seek an appro
priate professio
nal.
Northeast is supplying inform
ation only. P
CI Northeast is not re
ndering engineering or other professio
nal s
ervices
or da
mages arising out of this inform
ation. P
CI Northeast has publis
hed this work with the understa
nding that P
CI
sources belie
ved to be relia
ble. P
CI Northeast or its me
mbers
hips shall not be responsible for any errors, o
missio
n
The details sho
wn are guidelin
es and should not be considere
d sta
ndards. T
he inform
ation has been obtained fro
m
ISS
UE
DATE: 03 / 10 / 15
NEXT E BEAMS
NEXT E BEAMS - TANGENT PROFILE
NEXT E BEAMS - CREST VERTICAL CURVE PROFILE
NEXT E BEAMS - SAG VERTICAL CURVE PROFILE
OPTION 2: VARY OVERLAY THICKESS
OPTION 1: VARY TOPPING THICKESS
WEARING SURFACE
CONSTANT HEIGHT CURB/BARRIER
CONSTANT THICKNESS OVERLAY
THICKNESS VARIES
CURB/BARRIER HEIGHT VARIES
OVERLAY THICKNESS VARIES
CONSTANT THICKNESS TOPPING
TOP FLANGE4" INTEGRAL PARTIAL DECK/
CAUSED BY BEAM CAMBERTHICKER TOPPING THICKNESS AT ENDS
PLUS BEAM CAMBERCAUSED BY VERTICAL CURVE ORDINATETHICKER TOPPING THICKNESS AT ENDS
4•" MINIMUMREINFORCED CIP CONCRETE DECK
MINIMUM TOPPING THICKNESS AT MID-SPAN
MINIMUM TOPPING THICKNESS IF CAMBER IS LESS THAN ORDINATECURVE ORDINATE IS LARGER THAN CAMBERTHICKER TOPPING THICKNESS AT MID-SPAN IF VERTICAL
THICKER TOPPING IF CAMBER IS LESS THAN ORDINATECURVE ORDINATE IS LARGER THAN CAMBERMINIMUM TOPPING THICKNESS AT ENDS IF VERTICAL
MINIMUM TOPPING THICKNESS AT MID-SPAN
NE
XT
D - P
RO
FIL
E
AC
CO
MM
OD
ATIO
N
DET
AIL
S
NOTES
NE
XT 04
CH
AN
GE
D
RAILIN
G
TO
CO
NC
RETE
BA
RRIE
R10 / 2
015
1
1
1
1
GUIDE.
CAMBER, SEE PCI NORTHEAST PROFILE AND CAMBER MANAGEMENT
6. FOR MORE INFORMATION ON ACCOMMODATION OF PROFILES AND
SHOULD BE BASED ON THE ESTIMATED CAMBER AT ERECTION.
5. THE ESTIMATED CAMBER USED FOR THE VARIABLE NOTED ABOVE
THICKNESS TOP FLANGE AND/OR TOPPING IN THE DESIGN OF THE BEAM.
4. THE ENGINEER SHOULD ACCOUNT FOR THE ESTIMATED VARIABLE
THE SAME APPLIES TO THE HEIGHT OF THE CURB OR BARRIER.
ADJUSTMENT OF THE OVERLAY THICKNESS MAY BE REQUIRED.
REQUIRING SURVEY OF THE BEAMS AFTER ERECTION, AND THEN
THE ESTIMATED CAMBER. THE PLANS SHOULD INCLUDE NOTES
THICKNESS OF THE TOP FLANGE OR OVERLAY ON THE PLANS BASED ON
3. THE ENGINEER SHOULD DETAIL THE ANTICIPATED VARIABLE
DETAILS.
ORDINATE, THE DETAILS WILL BE SIMILAR TO THE TANGENT PROFILE
2. CREST VERTICAL CURVES: IF THE CAMBER IS LESS THAN THE CURVE
NOTE THAT THE HEIGHT OF THE CURB OR PARAPET WILL STILL VARY.
FLANGE. ANOTHER OPTION IS TO VERY THE THICKNESS OF THE OVERLAY.
1. THE DETAILS SHOWN DEPICT VARYING THE THICKNESS OF THE TOP
RE
VISIO
NS
DES
CRIP
TIO
ND
ATE
NO.
SH
EET:
TM
PCI
DIS
CLAIM
ER:
PR
EC
AST/P
RESTR
ESSE
D
CO
NC
RETE IN
STIT
UTE
NO
RT
HE
AST
WW
W.P
CIN
E.O
RG
NO
RT
HE
AST E
XTR
EM
E TEE (N
EXT)
BE
AM
DET
AIL
S
thro
ugh this guidelin
e. If such services are re
quired, please seek an appro
priate professio
nal.
Northeast is supplying inform
ation only. P
CI Northeast is not re
ndering engineering or other professio
nal s
ervices
or da
mages arising out of this inform
ation. P
CI Northeast has publis
hed this work with the understa
nding that P
CI
sources belie
ved to be relia
ble. P
CI Northeast or its me
mbers
hips shall not be responsible for any errors, o
missio
n
The details sho
wn are guidelin
es and should not be considere
d sta
ndards. T
he inform
ation has been obtained fro
m
ISS
UE
DATE: 03 / 10 / 15
NEXT D BEAMS
NEXT D BEAMS - TANGENT PROFILE
NEXT D BEAMS - CREST VERTICAL CURVE PROFILE
NEXT D BEAMS - SAG VERTICAL CURVE PROFILE
OPTION 1: VARY FLANGE THICKESS
OPTION 2: VARY OVERLAY THICKESS
WEARING SURFACE
CAUSED BY BEAM CAMBERTHICKER TOP FLANGE THICKNESS AT ENDS
INTEGRAL DECK/TOP FLANGE8" MINIMUM
CONSTANT HEIGHT CURB/BARRIER
CONSTANT OVERLAY THICKNESS
PLUS BEAM CAMBERCAUSED BY VERTICAL CURVE ORDINATETHICKER TOP FLANGE THICKNESS AT ENDS
BARRIER/CURB HEIGHT VARIES
OVERLAY THICKNESS VARIES
CONSTANT FLANGE THICKNESS
MINIMUM TOP FLANGE THICKNESS AT MID-SPAN
MINIMUM TOP FLANGE THICKNESS IF CAMBER IS LESS THAN ORDINATECURVE ORDINATE IS LARGER THAN CAMBERTHICKER TOP FLANGE THICKNESS AT MID-SPAN IF VERTICAL
THICKER TOPPING IF CAMBER IS LESS THAN ORDINATECURVE ORDINATE IS LARGER THAN CAMBERMINIMUM TOP FLANGE THICKNESS AT ENDS IF VERTICAL
THICKNESS VARIESTOP FLANGE
MINIMUM TOP FLANGE THICKNESS AT MID-SPAN
FLANGES UNDER 10 1/2"
FLANGE ADJUSTMENT FOR PROFILE
FLANGES OVER 10 1/2"
NORMAL DECK REINFORCEMENT
#4 @ 6"
2-#4
#4 @ 6"
2•
"
OV
ER
10•
"
VA
RI
ES
8"
TO
10•
"
VA
RI
ES
NE
XT B
EA
M - T
YPIC
AL B
EA
M
REIN
FO
RCIN
G
GENERAL NOTES
DESIGN NOTES
STRAND LAYOUT NOTES
01 / 2
016
1
1
1
1
1
LO
CATIO
N
OF T
OP STR
AN
D
&
REIN
F.
OF
NE
XT F
4. SEE SHEET 14 FOR UTILITIES SUPPORT DETAILS.
3. SHEAR REINFORCING SHOULD BE KEPT TO #4 BARS IN ORDER TO MAXIMIZE THE COVER ON THE SIDE OF THE STEM.
THE STEMS ARE INDIVIDUAL BEAMS.
2. THE DESIGN OF THE DECK REINFORCING SHOULD BE BASED ON A CONVENTIONAL CAST-IN-PLACE CONCRETE DECK ASSUMING THAT
ACTUAL DECK THICKNESS.
NEXT BEAM WITH AN 8• INCH THICK DECK. DESIGNERS SHOULD VERIFY THIS REINFORCING FOR EACH DESIGN BASED ON THE
SHOULD BE DESIGNED TO COMPLETE THE STRUCTURAL DECK. THE REINFORCING SHOWN IS BASED ON A PRELIMINARY DESIGN OF A
1. THE TOP FLANGE IS INTENDED TO ACT AS THE BOTTOM PORTION OF THE DECK. A REINFORCED CAST-IN-PLACE CONCRETE TOPPING
NEXT E NOTES:
INSTALLATION OF THE STIRRUPS.
4. MINOR ADJUSTMENT OF THE SPACING OF THE TOP LONGITUDINAL REINFORCEMENT IS ALLOWABLE TO FACILITATE THE
3. SEE SHEET 14 FOR UTILITY SUPPORT DETAILS.
2. SHEAR REINFORCING SHOULD BE KEPT TO #4 BARS IN ORDER TO MAXIMIZE THE COVER ON THE SIDE OF THE STEM.
1. THE TOP FLANGE IS INTENDED TO ACT AS A STRUCTURAL DECK.
NEXT D NOTES:
STRESS IN THE BEAM.
IN THE DESIGN, THEY SHOULD NOT BE USED TO MEET THESE AASHTO PROVISIONS, SINCE THEY ARE ALREADY BEING USED TO CONTROL
CRACK WIDTH AND LENGTH CONTROL, NOT PREVENTION. IT IS RECOMMENDED THAT IF FULLY TENSIONED TOP STRAND ARE INCLUDED
REINFORCING SHALL BE DESIGNED IN ACCORDANCE WITH THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS. THIS REINFORCING IS FOR
STRESSES EXCEED 200 PSI. THESE BARS ARE USED TO CONTROL TRANSVERSE CRACKING IN THE TOP FLANGE AT RELEASE. THIS
5. THE DESIGNER SHALL DETAIL ADDITIONAL TOP LONGITUDINAL REINFORCING IN THE TOP FLANGE AT BEAM ENDS IF THE TOP FIBER
4. ADDITIONAL REINFORCEMENT MAY BE REQUIRED FOR DECK OVERHANGS AND BARRIERS.
ALSO BE CHECKED FOR THESE BARS.
CONSIDERED A LAP SPLICE WITH THE BARS FULLY DEVELOPED. THE CRACK CONTROL PROVISIONS OF AASHTO ARTICLE 5.7.3.4. SHOULD
AT THE CENTER OF THE JOINT AS DETERMINED BY THE AASHTO STRIP METHOD OF DECK DESIGN. THE NESTED HOOKED BARS CAN BE
3. THE REINFORCING BARS EXTENSIONS SHOWN IN THE NEXT E AND D BEAMS SHOULD BE DESIGNED TO RESIST THE POSITIVE BENDING MOMENT
AND D BEAMS.
2. THE STRIP METHOD SPECIFIED IN AASHTO LRFD ARTICLE 4.6.2.1 IS RECOMMENDED FOR THE DESIGN OF THE REINFORCING IN THE NEXT E
AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS OR STATE STANDARDS.
1. THE REINFORCING SHOWN IS PRELIMINARY AND NOT GUARANTEED. DESIGNERS MUST VERIFY THE REINFORCING FOR EACH DESIGN BASED ON THE
8. ADDITIONAL STRAND TENSIONED TO A NOMINAL VALUE MAY BE ADDED TO THE TOP FLANGE TO SUPPORT THE TOP FLANGE REINFORCING.
THE ULTIMATE STRENGTH OF THE STRANDS SHALL BE 270 KSI.
7. ALL PRESTRESSING STRAND SHALL BE 0.6" DIAMETER, UNCOATED SEVEN WIRE, LOW RELAXATION STRANDS CONFORMING TO AASHTO M203.
6. THE TWO BOTTOM CORNER STRAND IN EACH STEM ARE OMITTED TO PROVIDE ROOM FOR THE SHEAR REINFORCEMENT BAR BENDS.
ON THE CAPACITY OF TYPICAL CASTING BEDS.
THE TOP STRAND). THIS IS BASED 5. THE PATTERN SHOWN DEPICTS THE MAXIMUM NUMBER OF STRANDS ALLOWED (50 STRAND INCLUDING
PRESTRESS AT A HIGHER ELEVATION. THE NUMBER AND LOCATION OF STRANDS SHALL BE AS REQUIRED BY DESIGN.
4. STRANDS SHALL BE PLACED WITHIN THE 2"x2" GRID. THE PATTERN MAY BE RAISED IN 2" INCREMENTS FOR DESIGNS THAT REQUIRE
THIS 6" AREA.
TO CONTROL END CRACKING. SPACING RESTRICTIONS OUTLINED IN NOTE 2 DO NOT APPLY TO THIS 6" AREA, BUT DO APPLY BEYOND
3. IT IS RECOMMENDED THAT APPROXIMATELY 50% OF ALL STRAND BE DEBONDED FOR THE FIRST 6" FROM THE END OF THE BEAM IN ORDER
DESIGN SPECIFICATIONS SHALL ALSO BE FOLLOWED.
DEBONDED STRANDS SHALL BE AT LEAST 2.5 INCHES IN ANY DIRECTION. THE RESTRICTIONS OUTLINED IN THE AASHTO LRFD BRIDGE
SHALL BE DEBONDED. THE SPACING BETWEEN 2. DEBONDING OF STRAND IS ALLOWED. NO MORE THAN 25% OF THE TOTAL NUMBER OF STRANDS
1. DENOTES STRAIGHT STRAND. DRAPED STRANDS ARE NOT PERMITTED.
1
5. SEE SHEET 14 FOR UTILITIES SUPPORT DETAILS.
4. SHEAR REINFORCING SHOULD BE KEPT TO #4 BARS IN ORDER TO MAXIMIZE THE COVER ON THE SIDE OF THE STEM.
OVERHANG LOADS.
3. THE ADDITIONAL TOP STEEL IN THE BEAM OVERHANGS SHOULD ONLY BE USED WHERE THE WELDED WIRE FABRIC CANNOT SUPPORT THE
THE BARS DOES NOT EXCEED 12 INCHES.
ADJACENT TO THE CUT FABRIC. EQUIVALENT MILD REINFORCEMENT MAY ALSO BE USED IN PLACE OF THE WWF, PROVIDED THAT THE SPACING OF
2. THE WELDED WIRE FABRIC MAY BE CUT TO FACILITATE THE INSTALLATION AROUND THE STIRRUPS, PROVIDED THAT EQUIVALENT BARS ARE ADDED
BASED ON THE ACTUAL DECK THICKNESS.
REINFORCING SHOWN IS BASED ON AN 8" THICK CAST-IN-PLACE DECK. DESIGNERS SHOULD VERIFY THIS REINFORCING FOR EACH DESIGN
BETWEEN STEMS. THE WELDED WIRE FABRIC SHOWN IS PRELIMINARY AND SHOULD BE USED TO SUPPORT THE WET DECK CONCRETE ONLY. THE
1. THE TOP FLANGE IS INTENDED TO ACT AS A DECK FORM ONLY. A REINFORCED CAST-IN-PLACE CONCRETE DECK SHOULD BE DESIGNED TO SPAN
NEXT F NOTES:
NE
XT 05
RE
VISIO
NS
DES
CRIP
TIO
ND
ATE
NO.
SH
EET:
TM
PCI
DIS
CLAIM
ER:
PR
EC
AST/P
RESTR
ESSE
D
CO
NC
RETE IN
STIT
UTE
NO
RT
HE
AST
WW
W.P
CIN
E.O
RG
NO
RT
HE
AST E
XTR
EM
E TEE (N
EXT)
BE
AM
DET
AIL
S
thro
ugh this guidelin
e. If such services are re
quired, please seek an appro
priate professio
nal.
Northeast is supplying inform
ation only. P
CI Northeast is not re
ndering engineering or other professio
nal s
ervices
or da
mages arising out of this inform
ation. P
CI Northeast has publis
hed this work with the understa
nding that P
CI
sources belie
ved to be relia
ble. P
CI Northeast or its me
mbers
hips shall not be responsible for any errors, o
missio
n
The details sho
wn are guidelin
es and should not be considere
d sta
ndards. T
he inform
ation has been obtained fro
m
ISS
UE
DATE: 03 / 10 / 15
#4 STIRRUP (TYP)
1ƒ" COVER WITH
4 SP @ 2" (TYP)
2•" (TYP)
4 SP @ 2" = 8" (TYP)
#4 STIRRUPS (TYP)
(TYP)
HORIZONTAL SHEAR RESISTANCE
EXTEND STIRRUPS TO PROVIDE
OF EACH STEM
2 STRANDS AT TOP
(USE WWF IF POSSIBLE)
BARS TO CENTER OF BEAM
OVERHANG LOADS (TYP) EXTEND
ADDITIONAL REINFORCING FOR
0"
1" RECOMMENDED
MIN. COVER ALLOWED BY AGENCY
RAKE FINISH
+4"
NEXT F BEAM
SEE SHEET 08 FOR DETAILSINVERTED U SHAPED BAR. DOUBLE BARS SHOWN MAY BE COMBINED INTO ONE 6" INSIDE RADIUS OR EQUIVALENT MULTIPLE BENDS.#5 J BAR (20"x10") END ZONE REINFORCING (TYP)
1•" (TYP)
OF TOP FLANGE (SEE NOTE 2)
4x4 W4xW4 WWF PLACED AT MID-DEPTH
#4 STIRRUP (TYP)
1ƒ" COVER WITH
4 SP @ 2" = 8" (TYP)
0"
1" RECOMMENDED
MIN. COVER ALLOWED BY AGENCY
4 SP @ 2" (TYP)
2•" (TYP)
RAKE FINISH
(TYP)
HORIZONTAL SHEAR RESISTANCE
EXTEND STIRRUPS TO PROVIDE
OF EACH STEM
2 STRANDS AT TOP#4 STIRRUPS (TYP)
SEE DETAILS, SHEET 9
HOOKED BAR CONNECTOR
+2"
NEXT E BEAMSEE SHEET 09 FOR DETAILSINVERTED U SHAPED BAR. DOUBLE BARS SHOWN MAY BE COMBINED INTO ONE 6" INSIDE RADIUS OR EQUIVALENT MULTIPLE BENDS#5 J BAR (20"x10") END ZONE REINFORCING (TYP)
6" SPACING RECOMMENDED
REINFORCING (TYP)
BOTTOM TRANSVERSE DECK1•" (TYP)
#4 STIRRUP (TYP)
1ƒ" COVER WITH
DECK FINISH
4 SP @ 2" (TYP)
2•" (TYP)
4 SP @ 2" = 8" (TYP)
#4 STIRRUPS (TYP)
1•
"
2•
"2"
(TYP)
8"
6" ON CENTER (TYP)
#4 HOOKED REINFORCING BAR
#4@6" TOP AND BOTTOM
#4@9" TOP AND BOTTOM (TYP)
NEXT D BEAM
0"
1" RECOMMENDED
MIN. COVER ALLOWED BY AGENCY
OF EACH STEM
2 STRANDS AT TOP
SEE SHEET 10 FOR DETAILSINVERTED U SHAPED BAR. DOUBLE BARS SHOWN MAY BE COMBINED INTO ONE 6" INSIDE RADIUS OR EQUIVALENT MULTIPLE BENDSOPTIONAL #5 J BAR (20"x10") END ZONE REINFORCING (TYP)
90° HOOK
DESIGNATION
BEAM
INCHES
DEPTH
BEAM
IN
AREA
INCHES
Yb
IN
I
IN
St
IN
Sb
PLF
WEIGHT
2 34 3INCHES
Yt
INCHES
WIDTH
BASE STEM
DCA B
INCHES
WIDTH
BEAM
E
FLANGE OVERHANGS SHOULD BE CHAMFERED 6"x6" IN ORDER TO MINIMIZE CASTING AND HANDLING DAMAGE.
4. THE ENDS OF THE BEAMS SHOULD BE SKEWED FOR SKEWED BRIDGES. THE ACUTE CORNERS OF THE
3. THE STEM WIDTH AND SPACING ARE FIXED.
BEAM MAY REQUIRE A SPECIAL DESIGN WITH A NON-SYMMETRICAL STRAND PATTERN.
SYMMETRICAL ABOUT THE VERTICAL AXIS. NON-SYMMETRICAL SECTIONS ARE POSSIBLE, HOWEVER THE
OVERHANG OF THE FASCIA BEAMS ALONG THE LENGTH. INTERIOR BEAMS SHOULD ALWAYS BE
2. BRIDGES WITH SMALL CURVATURE CAN BE BUILT USING THESE SECTIONS BY VARYING THE
WILL NEED TO CALCULATE BEAM PROPERTIES FOR BEAMS THAT ARE NOT EQUAL TO THE WIDTHS LISTED.
VARIATION IN WIDTH IS ACCOMPLISHED BY VARYING THE OVERHANG DIMENSIONS. THE DESIGNER
THESE LIMITS IS ALLOWED IN ORDER TO CONSTRUCT A BRIDGE TO THE REQUIRED WIDTH. THE
1. THE WIDTH OF BEAMS SHOWN ARE THE MINIMUM AND MAXIMUM WIDTH BEAMS. VARIATION BETWEEN
ALL NEXT BEAM TYPES:
2. MODIFY THE FASCIA BEAM DECK EDGE TO MATCH STATE STANDARDS.
(EX.: BEAM SPACING = 10'-9" FOR THE 10'-0" SECTION).
1. THE SPACING OF BEAMS ON A TYPICAL BRIDGE SHALL BE THE WIDTH OF THE BEAM PLUS 9"
NEXT D BEAMS:
SPACING (EX.: BEAM SPACING = 12 FEET FOR THE 11'-11•" SECTION).
ACCOUNT FOR TOLERANCES. THE SPACING OF BEAMS ON A TYPICAL BRIDGE SHALL BE AT THE NOMINAL
1. THE ACTUAL WIDTH OF THE BEAM TAKE INTO ACCOUNT A NOMINAL •" WIDE GAP BETWEEN BEAMS TO
NEXT F BEAMS:
NE
XT B
EA
M - SE
CTIO
N
PR
OPE
RTIE
S
BEAM DIMENSION NOTES
NEXT BEAM - SECTION PROPERTIES
NE
XT 06
RE
VISIO
NS
DES
CRIP
TIO
ND
ATE
NO.
SH
EET:
TM
PCI
DIS
CLAIM
ER:
PR
EC
AST/P
RESTR
ESSE
D
CO
NC
RETE IN
STIT
UTE
NO
RT
HE
AST
WW
W.P
CIN
E.O
RG
NO
RT
HE
AST E
XTR
EM
E TEE (N
EXT)
BE
AM
DET
AIL
S
thro
ugh this guidelin
e. If such services are re
quired, please seek an appro
priate professio
nal.
Northeast is supplying inform
ation only. P
CI Northeast is not re
ndering engineering or other professio
nal s
ervices
or da
mages arising out of this inform
ation. P
CI Northeast has publis
hed this work with the understa
nding that P
CI
sources belie
ved to be relia
ble. P
CI Northeast or its me
mbers
hips shall not be responsible for any errors, o
missio
n
The details sho
wn are guidelin
es and should not be considere
d sta
ndards. T
he inform
ation has been obtained fro
m
ISS
UE
DATE: 03 / 10 / 15
5'-0"
CC
B
1'-3" 1'-3"4"
ƒ" CHAMFER (TYP)
RAKE FINISH
0.375
12
R=4" (TYP)
Yt
Yb
C.G.
A/2A/2
DIMENSION A (MAXIMUM 11'-11•") FOR 12'-0" BEAM SPACING
DIMENSION A (MINIMUM 7'-11•") FOR 8'-0" BEAM SPACING
‚" DRAFT ON EDGE
NEXT F BEAM
5'-0"
CC
B
1'-3" 1'-3"4"
ƒ" CHAMFER (TYP)
RAKE FINISH
0.375
12
R=4" (TYP)
Yt
Yb
C.G.
A/2A/2
CHAMFER ON FASCIA EDGE
‚" DRAFT WITH ƒ"
FASCIA EDGESINTERIOR EDGES
DIMENSION A (MINIMUM 8'-0") FOR 9'-4" BEAM SPACING
DIMENSION A (MAXIMUM 9'-6") FOR 10'-10" BEAM SPACING
NEXT E BEAM
5'-0"
CC
B
1'-3" 1'-3"
ƒ" CHAMFER (TYP)
0.375
12
R=4" (TYP)
Yt
Yb
C.G.
A/2A/2
8"
DECK FINISH
DIMENSION A (MAXIMUM 10'-0") FOR 10'-9" BEAM SPACING
DIMENSION A (MINIMUM 8'-0") FOR 8'-9" BEAM SPACING
NEXT D BEAM
BRIDGE SECTION NOTES
1
10 / 2
015
1C
HA
NG
ED
RAILIN
G
TO
CO
NC
RETE
BA
RRIE
R
1
1
1
1
1
MAXIMUM SPAN LENGTH DESIGN ASSUMPTIONS
15. ALL DESIGNS WERE GOVERNED BY THE SERVICE LIMIT STATE.
REQUIREMENTS FOR SPAN/DEPTH RATIOS.
1). DESIGNERS SHOULD LIMIT SPAN LENGTHS ACCORDING TO THE OWNER'S
AASHTO LRFD RECOMMENDED SPAN/DEPTH RATIOS WERE NOT CONSIDERED (SEE FOOTNOTE 14.
STRESS LIMIT REQUIREMENTS AT RELEASE.
PRESENT AT THE TOP OF BEAM ENDS TO MEET THE ALLOWABLE TEMPORARY TENSILE
ADEQUATE SUPPLEMENTAL BONDED LONGITUDINAL REINFORCEMENT IS ASSUMED TO BE 13.
BARRIER WEIGHT IS EVENLY DISTRIBUTED TO ALL BEAMS12.
EACH STEM TREATED AS AN INDIVIDUAL BEAM USING AVERAGE STEM SPACING
LIVE LOAD DISTRIBUTION FACTORS: AASHTO LRFD SPECIFICATION (TYPE K) WITH 11.
BEAM DESIGNS ARE FOR SIMPLY SUPPORTED INTERIOR BEAMS10.
ALLOWABLE TENSILE STRESSES: BASED ON EXTREME EXPOSURE9.
TOP STRAND ARE CONSIDERED TO BE FULLY TENSIONED8.
DEBONDING: INCLUDED AT BEAM ENDS7.
COMPOSITE TOPPING CONCRETE STRENGTH (NEXT F AND E): 4 KSI6.
UTILITY LOADS: NONE5.
WEARING SURFACE: 3" THICK ASPHALT4.
BARRIERS: MASSDOT CF-PL2 BARRIER (457 PLF)3.
EDITION (2014) WITH 2015 & 2016 INTERIM REVISIONS
DESIGN SPECIFICATIONS: AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, 7TH 2.
DIFFERENT CONFIGURATIONS WILL PRODUCE DIFFERENT MAXIMUM SPAN LENGTHS.
THE DESIGNS CORRESPOND TO THE CROSS SECTION GEOMETRIES SHOWN ON THIS SHEET. 1.
THESE MAXIMUM SPAN LENGTHS.
FOLLOWING ARE THE DESIGN CRITERIA AND ASSUMPTIONS USED FOR THE DEVELOPMENT OF
ACTUAL MAXIMUM SPAN LENGTHS ARE AFFECTED BY A NUMBER OF ASSUMPTIONS. THE
THE VALUES SHOWN ARE NOT GUARANTEED AND SHOULD BE CONSIDERED APPROXIMATE. THE
OFFSET.
DIMENSIONS OF ALL BEARING LOCATIONS ON THE PLANS SHOULD ACCOUNT FOR THIS ROTATIONAL
SLOPE AND ROTATION OF THE BEAMS RELATIVE TO THE LONGITUDINAL AXIS OF THE BEAM. THE
3. OFFSET THE BEARING SUPPORT LOCATIONS FROM THE ROADWAY BASELINE ACCOUNTING FOR THE CROSS
SPECIAL SHIPPING CONSIDERATIONS, WHICH WILL LEAD TO AN INCREASE IN SHIPPING COSTS.
THE LIMITS OF THE BEAM FORMS. (12' MAXIMUM CONCRETE SECTION). THIS OPTION MAY REQUIRE
LIEU OF THIS OPTION, THE DESIGNER CAN CONSIDER THE USE OF WIDER OR NARROWER BEAMS WITHIN
OPTION SHOULD ONLY BE USED IN SPECIAL SITUATIONS AND WITH APPROVAL FROM THE OWNER. IN
WIDTHS. SPECIAL TEMPORARY BRACING WILL BE REQUIRED FOR SHIPPING AND ERECTION. THIS
2. IN SPECIAL CASES, A HALF WIDTH BEAM SECTION CAN BE USED TO ACCOMODATE UNUSUAL BRIDGE
WIDTH NEXT BEAMS.
1. THE BRIDGE SECTIONS DEPICTED REPRESENT THE TYPICAL USE OF THE MINIMUM WIDTH AND MAXIMUM
211 / 2017
AD
DE
D
SP
AN
TA
BLE
AN
D
NO
TES
2
NE
XT B
EA
M - T
YPIC
AL B
RID
GE SE
CTIO
NS
NE
XT 07
RE
VISIO
NS
DES
CRIP
TIO
ND
ATE
NO.
SH
EET:
TM
PCI
DIS
CLAIM
ER:
PR
EC
AST/P
RESTR
ESSE
D
CO
NC
RETE IN
STIT
UTE
NO
RT
HE
AST
WW
W.P
CIN
E.O
RG
NO
RT
HE
AST E
XTR
EM
E TEE (N
EXT)
BE
AM
DET
AIL
S
thro
ugh this guidelin
e. If such services are re
quired, please seek an appro
priate professio
nal.
Northeast is supplying inform
ation only. P
CI Northeast is not re
ndering engineering or other professio
nal s
ervices
or da
mages arising out of this inform
ation. P
CI Northeast has publis
hed this work with the understa
nding that P
CI
sources belie
ved to be relia
ble. P
CI Northeast or its me
mbers
hips shall not be responsible for any errors, o
missio
n
The details sho
wn are guidelin
es and should not be considere
d sta
ndards. T
he inform
ation has been obtained fro
m
ISS
UE
DATE: 03 / 10 / 15
SHEET 04SEE JOINT DETAILS
SHEET 04SEE JOINT DETAILS
WEARING SURFACE
WEARING SURFACE
SEE NOTE 4
8'-9" 8'-9" 8'-9"4'-0" 4'-0"
12'-0" LANE12'-0" LANE
5'-0"
SEE NOTE 4
10'-9"10'-9" 5'-0"
12'-0" LANE
NEXT D BEAMS - MAXIMUM WIDTH BEAMS
NEXT D BEAMS - MINIMUM WIDTH BEAMS
1'-7‚"1'-7‚"
3'-4•"3'-4•"
33'-11•"
1'-7‚"1'-7‚"
2'-ƒ"2'-ƒ" 12'-0" LANE
31'-4"
5'-11ƒ"5'-11ƒ" 12'-0"12'-0"
4'-4•"
1'-7‚"1'-7‚"
8'-0" 8'-0" 8'-0"
SEE DETAIL BELOW
ROADWAY BASELINE
ROADWAY BASELINE
SEE NOTE 4
WEARING SURFACECONCRETE DECK
8" MIN. REINFORCED
12'-0" LANE
12'-0" LANE 12'-0" LANE
3'-11ƒ" 3'-11ƒ"
WEARING SURFACESEE GAP DETAIL
CONCRETE DECK
8" MIN. REINFORCED
SEE NOTE 4
NEXT F BEAMS - MAXIMUM WIDTH BEAMS
NEXT F BEAMS - MINIMUM WIDTH BEAMS
1'-7‚"
1'-7‚"1'-7‚"
2'-4•"2'-4•"
4'-4•" 12'-0" LANE
28'-9"
32'-9"
1'-7‚"
CONCRETE DECK
4•" MINIMUM REINFORCED
CONCRETE DECK
4•" MINIMUM REINFORCED WEARING SURFACE
WEARING SURFACE
31'-6"
12'-0" LANE12'-0" LANE
12'-0" LANE 12'-0" LANE
4'-9" 10'-10"10'-10" 4'-9"
3'-11ƒ" 9'-4" 9'-4" 9'-4" 3'-11ƒ"
SEE NOTE 4
NEXT E BEAMS - MAXIMUM WIDTH BEAMS
NEXT E BEAMS - MINIMUM WIDTH BEAMS
SEE NOTE 4
4'-5ƒ" 4'-5ƒ"
36'-2"
1'-7‚"
1'-7‚"1'-7‚"
2'-1ƒ" 2'-1ƒ"
NE
XT F B
EA
M - D
EC
K
DET
AIL
S
1
CH
AN
GE
D
RAILIN
G
TO
CO
NC
RETE
BA
RRIE
R10 / 2
015
1
NE
XT 08
RE
VISIO
NS
DES
CRIP
TIO
ND
ATE
NO.
SH
EET:
TM
PCI
DIS
CLAIM
ER:
PR
EC
AST/P
RESTR
ESSE
D
CO
NC
RETE IN
STIT
UTE
NO
RT
HE
AST
WW
W.P
CIN
E.O
RG
NO
RT
HE
AST E
XTR
EM
E TEE (N
EXT)
BE
AM
DET
AIL
S
thro
ugh this guidelin
e. If such services are re
quired, please seek an appro
priate professio
nal.
Northeast is supplying inform
ation only. P
CI Northeast is not re
ndering engineering or other professio
nal s
ervices
or da
mages arising out of this inform
ation. P
CI Northeast has publis
hed this work with the understa
nding that P
CI
sources belie
ved to be relia
ble. P
CI Northeast or its me
mbers
hips shall not be responsible for any errors, o
missio
n
The details sho
wn are guidelin
es and should not be considere
d sta
ndards. T
he inform
ation has been obtained fro
m
ISS
UE
DATE: 03 / 10 / 15
•" TOLERANCE+•"
TOP FLANGE OF NEXT BEAM
DIFFERENTIAL CAMBER
SEAL MATERIAL AS REQUIRED
REINFORCED CONCRETE DECK
NEXT F BEAM - GAP FORM DETAIL
CURB INTO DECK SLAB OVERPOUR
BARS PROJECTING FROM PRECAST
PLACE CURB IN GROUT BED
CAST DECK AFTER CURB PLACEMENT
WEARING SURFACE
OVERHANG (IF DESIRED)
DRIP EDGE
TRANSVERSE DECK REINFORCING
CONSTRUCTION SEQUENCE
INTO THE DECK SLAB
SECTION WITH BARS PROJECTING
PRECAST CONCRETE CURB
MEMBRANE WATERPROOFING
NEXT BEAM
LOOP DOWEL (TYP)
#5 DOWEL
FOAM BACKER ROD (TYP)
4"x4" KEYWAY (TYP)
5. PLACE WEARING SURFACE (IF REQUIRED)
4. SEAL THE JOINT BETWEEN THE PARAPET AND DECK WITH FLEXIBLE JOINT SEAL
3. PLACE DECK REINFORCEMENT AND CAST THE DECK OVERPOUR
2. PLACE PRECAST PARAPET IN GROUT BED, GROUT JOINTS IN PARAPET
1. ERECT NEXT BEAM
NON-SHRINK GROUT
FILL VOID WITH
REINFORCING (TYP)
NORMAL PARAPET
CAST-IN-PLACE CONCRETE BARRIERS MAY ALSO BE USED WITH SIMILAR DETAILS.
ALLOW SETTING OF PRECAST CURB/BARRIER.
STIRRUP SPACING MAY NEED TO BE MODIFIED IF ONE LEG OF STIRRUP IS ELIMINATED IN ORDER TO
ALL REINFORCING IN BEAM AND DECK POUR NOT SHOWN.
ANCHOR BOLTS NOT SHOWN IN CURB.
THIS DETAIL CAN BE MODIFIED FOR ANY TYPICAL PARAPET SHAPE INCLUDING F SHAPE PARAPETS.
STEEL RAIL IN CURB SHOWN, OTHER PARAPETS SIMILAR.
NOTES: THIS DETAIL IS SCHEMATIC. ACTUAL DETAIL WOULD NEED TO BE FULLY DESIGNED.
SECTION
PLAN
NEXT F BEAM - PRECAST PARAPET OPTIONS
JOINT SEAL
DETAILS AS PER STATE STANDARDS
WATERPROOFING MEMBRANE CURB
VERTICALS
ADDITIONAL END ZONE
#4
BURSTING STEEL IN END ZONE
SHEAR REINFORCEMENT USED FOR
ANCHOR REAR FACE VERTICALS IN MIDDLE OF STRAND GRID
END ZONE IF REQUIRED
STIRRUPS MAY BE BUNDLED IN
STATE STANDARDS)
BLOCKOUT (SEE
RECOMMENDED 20 DEGREES MAX.
STANDARD STIRRUP
PLAN - SKEWED END
END ELEVATION - STEM ENDELEVATION - STEM END
(AASHTO LRFD 5.10.10.1)
BURSTING ZONE = h/4
1.5xh
NOTE: h = TOTAL HEIGHT OF MEMBER
VERTICALS
ADDITIONAL END ZONE
#4
REINFORCING.
SUPPLEMENTAL FLANGE
1"
CO
VE
R
OF TOP FLANGE. SEE NOTE 3
#4 BARS PLACED AT MID DEPTH
PLACE IN BOTH STEMS
20 SPACES @ 6"=10'
#5 L BAR (20"X10")
NOTE: NORMAL TOP FLANGE REINFORCEMENT NOT SHOWN
0"
FABRICATION AND HANDLING
FOR CRACKING IN THE TOP FLANGE DURING
STRONGLY DISCOURAGED DUE TO POTENTIAL
BEAMS WITH HIGHER SKEWS ARE
POTENTIAL SHIPPING LIMITATIONS.
SKEWED BEAMS REGARDING
FABRICATORS FOR LONG SPAN
CONSULT WITH SEVERAL
NOTE: DESIGNERS SHOULD
NEXT F BEAM - END REINFORCING DETAILS
SEE NOTE 1
BURSTING ZONE VERTICAL REINFORCING
NORMAL SHEAR REINFORCEMENT
FLANGE. SEE NOTE 3
MID-DEPTH OF TOP
#4 BARS PLACED AT
INVERTED U SHAPED BAR
OPPOSING J BARS MAY BE COMBINED INTO ONE
J BARS MAY BE PLACED NORMAL TO STEM
THEY SHOULD NOT BE USED TO MEET THESE AASHTO PROVISIONS.
IS FOR CRACK WIDTH AND LENGTH CONTROL, NOT PREVENTION. IF FULLY TENSIONED TOP STRAND ARE INCLUDED IN THE DESIGN,
REINFORCING SHALL BE DESIGNED IN ACCORDANCE WITH THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS. THIS REINFORCING
STRESSES EXCEED 200 PSI. THESE BARS ARE USED TO CONTROL TRANSVERSE CRACKING IN THE TOP FLANGE AT RELEASE. THIS
4. THE DESIGNER SHALL DETAIL ADDITIONAL TOP LONGITUDINAL REINFORCING IN THE TOP FLANGE AT BEAM ENDS IF THE TOP FIBER
HELP TO PREVENT THE GROWTH OF THESE CRACKS DURING SHIPPING AND ERECTION.
INVERTED U SHAPED BAR.THE USE OF A SEMI-INTEGRAL BACKWALL THAT IS CAST IN THE SHOP AS A SECONDARY POUR CAN
#5 J BARS ARE USED TO SUPPLEMENT THIS REINFORCING. THE TWO J SHAPED BARS SHOWN MAY BE COMBINED INTO ONE
HAIRLINE CRACKS THROUGH THE INSIDE RADIUS OF THE TOP FLANGE / BEAM STEM INTERFACE RUNNING PARALLEL TO THE STEM.
DURING RELEASE AND HANDLING. THE MOST COMMON FORM OF POTENTIAL CRACKING IN THIS AREA IS A SERIES OF VERTICAL
3. PLACE 2-#4 BARS AT THE BEAM END, THEN #4 @ 6 INCHES IN THE TOP FLANGE TO CONTROL TOP FLANGE END CRACKING
REINFORCING SHOULD BE PLACED IN AREAS WHERE DEBONDING IS TERMINATED.
2. THE AMOUNT OF SPLITTING REINFORCING MAY BE REDUCED BY DEBONDING STRAND IN THIS AREA. ADDITIONAL SPLITTING
OF THESE ADDITIONAL END VERTICAL BARS MAY NOT BE NECESSARY DEPENDING ON THE DESIGN.
1. THE BARS SHOWN ARE APPROXIMATELY THE MAXIMUM NUMBER THAT CAN BE FIT WITHIN THE NEXT 24 BEAM. SOME OR ALL
NOTES:
NE
XT E
BE
AM - D
EC
K
DET
AIL
S
1
CH
AN
GE
D
RAILIN
G
TO
CO
NC
RETE
BA
RRIE
R10 / 2
015
1
NE
XT 09
RE
VISIO
NS
DES
CRIP
TIO
ND
ATE
NO.
SH
EET:
TM
PCI
DIS
CLAIM
ER:
PR
EC
AST/P
RESTR
ESSE
D
CO
NC
RETE IN
STIT
UTE
NO
RT
HE
AST
WW
W.P
CIN
E.O
RG
NO
RT
HE
AST E
XTR
EM
E TEE (N
EXT)
BE
AM
DET
AIL
S
thro
ugh this guidelin
e. If such services are re
quired, please seek an appro
priate professio
nal.
Northeast is supplying inform
ation only. P
CI Northeast is not re
ndering engineering or other professio
nal s
ervices
or da
mages arising out of this inform
ation. P
CI Northeast has publis
hed this work with the understa
nding that P
CI
sources belie
ved to be relia
ble. P
CI Northeast or its me
mbers
hips shall not be responsible for any errors, o
missio
n
The details sho
wn are guidelin
es and should not be considere
d sta
ndards. T
he inform
ation has been obtained fro
m
ISS
UE
DATE: 03 / 10 / 15
TO ADJACENT BAR IS LESS THAN 3" (TYP)
DISCONTINUE BARS WHEN SPACING
21" MINIMUM LAP SPLICE (TYP)
WITH MAIN DECK REINFORCING
SPLICE PROJECTING HOOK BARS
RECOMMENDED 20 DEGREES MAX.
SPLAY IN ACUTE END REGION (TYP)
2 AT BEAM END, THEN #4@6".
TRANSVERSE #4 DECK BARS,
PLAN
POTENTIAL SHIPPING LIMITATIONS.
SKEWED BEAMS REGARDING
FABRICATORS FOR LONG SPAN
CONSULT WITH SEVERAL
NOTE: DESIGNERS SHOULD
SKEWED BEAM ENDS
NEXT E BEAM - MAIN DECK REINFORCING DETAILS
PROJECTING HOOK BAR (TYP)
INSIDE FACE OF DECK EDGE (TYP)
BEND PROJECTING HOOK BARS JUST
FABRICATION AND HANDLING
FOR CRACKING IN THE TOP FLANGE DURING
STRONGLY DISCOURAGED DUE TO POTENTIAL
BEAMS WITH HIGHER SKEWS ARE
OF 6" SPACING BETWEEN ADJACENT TRANSVERSE DECK BARS.
FABRICATOR SHALL LAY OUT BARS TO PROVIDE A MAXIMUM
3. THE BAR LAYOUT SHOWN IS APPROXIMATE. THE
NOT SHOWN FOR CLARITY. SIMILAR TO NEXT F BEAMS.
2. OTHER REINFORCING BARS SUCH AS END ZONE REINFORCING
1. USE THIS DETAIL FOR ALL SKEWED BEAMS.
NOTES:
PLAN
6"
6"
4-#4
As req/As prov = 1
#4 BAR
EPOXY COATED
fy = 60 ksi
f'c = 4 ksi
DETAIL BASED ON:
1'-4"
1"+13"
4•
"4"
#4 REINFORCING BAR WITH 180° HOOK (TYP)
1"x1" CHAMFER (TYP.)
1•" BOTTOM COVER
2•" TOP COVER
#4 @ 9" (TYP.)
MI
N.
DECK CONCRETE
#4 @ 6"
#4 @ 9"
1'-2"
DIMENSIONS.
POUR WILL BE REQUIRED IN ORDER TO ACCOMMODATE THE HOOK
BOTTOM SHOWN. IF LARGER BARS ARE USED, A THICKER TOPPING
6. #4 BARS ARE REQUIRED TO PROVIDE THE MINIMUM CONCRETE
BY 1" TO ACCOUNT FOR FABRICATION AND ERECTION TOLERANCES.
PARAMETERS LISTED. THE MINIMUM LAP LENGTH SHALL BE INCREASED
5. THE DIMENSION SHOWN IS APPLICABLE TO A DESIGN WITH THE
IS EQUIVALENT TO A TENSION LAP SPLICE.
DEVELOPMENT LENGTH AS SPECIFIED IN AASHTO FOR HOOKED BARS
OF THIS JOINT. THE BASIS OF THE DESIGN IS THAT THE MINIMUM
4. DESIGNERS ARE RESPONSIBLE FOR THE VERIFICATION OF THE DESIGN
THE OWNER.
THE UNDERSIDE OF THE BEAM MAY BE USED WITH PERMISSION OF
ENGINEER. GALVANIZED OR STAINLESS STEEL INSERTS CAST INTO
NOT PENETRATE THROUGH TOP OF POUR UNLESS APPROVED BY THE
ACCOMMODATE DIFFERENTIAL CAMBER. FORM SUPPORTS SHOULD
CONTRACTOR. THE FORMS NEEDS TO BE REMOVABLE AND ABLE TO
3. METHOD OF FORMING CLOSURE POUR TO BE DETERMINED BY THE
PROJECTION.
WITHIN THE FLANGE IN ACUTE CORNERS TO PRODUCE A SQUARE
PERPENDICULAR TO BEAM EDGE. BEND CONNECTOR REINFORCING
2. FOR SKEWED BRIDGES, PLACE CONNECTOR REINFORCING
SPAN WITH 6" SPACING.
1. CONNECTOR REINFORCING TO BE PLACED ALONG THE ENTIRE
FLANGE CONNECTOR NOTES:
FLANGE
NEXT BEAM TOP
SECTION
NEXT E BEAM - FLANGE CONNECTION DETAILS
PLACE CURB IN GROUT BED
DRIP EDGE
NEXT BEAM
STIRRUP SPACING MAY NEED TO BE MODIFIED IF ONE LEG OF STIRRUP IS ELIMINATED.
ALL REINFORCING IN BEAM AND DECK POUR NOT SHOWN.
ANCHOR BOLTS NOT SHOWN IN CURB.
THIS DETAIL CAN BE MODIFIED FOR ANY TYPICAL PARAPET SHAPE INCLUDING F SHAPE PARAPETS.
STEEL RAIL IN CURB SHOWN, OTHER PARAPETS SIMILAR.
NOTES: THIS DETAIL IS SCHEMATIC. ACTUAL DETAIL WOULD NEED TO BE FULLY DESIGNED.
WEARING SURFACE
MEMBRANE WATERPROOFING
JOINT SEAL
DETAILS AS PER STATE STANDARDS
WATERPROOFING MEMBRANE CURB
NEXT E BEAM - RAILING OPTIONS
VERTICALS
ADDITIONAL END ZONE
#4
BURSTING STEEL IN END ZONE
SHEAR REINFORCEMENT USED FOR
ANCHOR REAR FACE VERTICALS IN MIDDLE OF STRAND GRID
END ZONE IF REQUIRED
STIRRUPS MAY BE BUNDLED IN
STATE STANDARDS)
BLOCKOUT (SEE
STANDARD STIRRUP
END ELEVATION - STEM ENDELEVATION - STEM END
VERTICALS
ADDITIONAL END ZONE
#4
1"
CO
VE
R
0"
PLACE IN BOTH STEMS
20 SPACES @ 6"=10'
#5 L BAR (20"X10")
(AASHTO LRFD 5.10.10.1)
BURSTING ZONE = h/4
NOTE: h = TOTAL HEIGHT OF MEMBER
NEXT E BEAM - END REINFORCING DETAILS
IN THE DESIGN, IT IS RECOMMENDED THAT THEY NOT BE USED TO MEET THESE AASHTO PROVISIONS.
BRIDGE DESIGN SPECIFICATIONS. THIS REINFORCING IS FOR CRACK WIDTH AND LENGTH CONTROL, NOT PREVENTION. IF FULLY TENSIONED TOP STRAND ARE INCLUDED
BARS ARE USED TO CONTROL TRANSVERSE CRACKING IN THE TOP FLANGE AT RELEASE. THIS REINFORCING SHALL BE DESIGNED IN ACCORDANCE WITH THE AASHTO LRFD
5. THE DESIGNER SHALL DETAIL ADDITIONAL TOP LONGITUDINAL REINFORCING IN THE TOP FLANGE AT BEAM ENDS IF THE TOP FIBER STRESSES EXCEED 200 PSI. THESE
4. SPLAY STIRRUPS IN ENDS OF STEM. SEE SHEET 08 FOR THE LAYOUT OF STIRRUPS (SIMILAR TO NEXT F BEAMS).
GROWTH OF THESE CRACKS DURING SHIPPING AND ERECTION.
INTO ONE INVERTED U SHAPED BAR. THE USE OF A SEMI-INTEGRAL BACKWALL THAT IS CAST IN THE SHOP AS A SECONDARY POUR CAN HELP TO PREVENT THE
STEM INTERFACE RUNNING PARALLEL TO THE STEM. #5 J BARS ARE USED TO SUPPLEMENT THIS REINFORCING. THE TWO J SHAPED BARS SHOWN MAY BE COMBINED
MOST COMMON FORM OF POTENTIAL CRACKING IN THIS AREA IS A SERIES OF VERTICAL HAIRLINE CRACKS THROUGH THE INSIDE RADIUS OF THE TOP FLANGE / BEAM
3. PLACE 2-#4 BARS AT THE BEAM END, THEN #5 @ 6 INCHES IN THE TOP FLANGE TO CONTROL TOP FLANGE END CRACKING DURING RELEASE AND HANDLING. THE
WHERE DEBONDING IS TERMINATED.
2. THE AMOUNT OF SPLITTING REINFORCING MAY BE REDUCED BY DEBONDING STRAND IN THIS AREA. ADDITIONAL SPLITTING REINFORCING SHOULD BE PLACED IN AREAS
MAY NOT BE NECESSARY DEPENDING ON THE DESIGN.
1. THE BARS SHOWN ARE APPROXIMATELY THE MAXIMUM NUMBER THAT CAN BE FIT WITHIN THE NEXT 24 BEAM. SOME OR ALL OF THESE ADDITIONAL END VERTICAL BARS
NOTES:
NE
XT
D
BE
AM - D
EC
K
DET
AIL
S
1
CH
AN
GE
D
RAILIN
G
TO
CO
NC
RETE
BA
RRIE
R10 / 2
015
1
2
03 / 2
016
2
2
RE
MO
VE
D
EXTR
A
DE
CK
BA
RS,
AD
DE
D J B
ARS,
AD
DE
D
NO
TE
NE
XT 10
RE
VISIO
NS
DES
CRIP
TIO
ND
ATE
NO.
SH
EET:
TM
PCI
DIS
CLAIM
ER:
PR
EC
AST/P
RESTR
ESSE
D
CO
NC
RETE IN
STIT
UTE
NO
RT
HE
AST
WW
W.P
CIN
E.O
RG
NO
RT
HE
AST E
XTR
EM
E TEE (N
EXT)
BE
AM
DET
AIL
S
thro
ugh this guidelin
e. If such services are re
quired, please seek an appro
priate professio
nal.
Northeast is supplying inform
ation only. P
CI Northeast is not re
ndering engineering or other professio
nal s
ervices
or da
mages arising out of this inform
ation. P
CI Northeast has publis
hed this work with the understa
nding that P
CI
sources belie
ved to be relia
ble. P
CI Northeast or its me
mbers
hips shall not be responsible for any errors, o
missio
n
The details sho
wn are guidelin
es and should not be considere
d sta
ndards. T
he inform
ation has been obtained fro
m
ISS
UE
DATE: 03 / 10 / 15
21" MINIMUM LAP SPLICE (TYP)
WITH MAIN DECK REINFORCING
SPLICE PROJECTING HOOP BARS
SPLAY IN ACUTE END REGION (TYP)
TRANSVERSE DECK BARS (#4@6")
RECOMMENDED 20 DEGREES MAX.
FABRICATION AND HANDLING
FOR CRACKING IN THE TOP FLANGE DURING
STRONGLY DISCOURAGED DUE TO POTENTIAL
BEAMS WITH HIGHER SKEWS ARE
OF 6" SPACING BETWEEN ADJACENT TRANSVERSE DECK BARS.
FABRICATOR SHALL LAY OUT BARS TO PROVIDE A MAXIMUM
3. THE BAR LAYOUT SHOWN IS APPROXIMATE. THE
NOT SHOWN FOR CLARITY.
2. OTHER REINFORCING BARS SUCH AS END ZONE REINFORCING
1. USE THIS DETAIL FOR ALL SKEWED BEAMS.
NOTES:
PLAN
POTENTIAL SHIPPING LIMITATIONS.
SKEWED BEAMS REGARDING
FABRICATORS FOR LONG SPAN
CONSULT WITH SEVERAL
NOTE: DESIGNERS SHOULD
SKEWED BEAM ENDS
NEXT D BEAM - MAIN DECK REINFORCING DETAILS
PROJECTING CONNECTION BAR (TYP)
PROJECTING CONNECTION BARS (TYP)
TO ADJACENT BAR IS LESS THAN 3" (TYP)
DISCONTINUE BARS WHEN SPACING
INSIDE FACE OF DECK EDGE (TYP)
BEND PROJECTING HOOP BARS JUST
PLAN
3"
3"
8"
2-#5
#4 @ 6"
1"
2•
"
MIN.
NEXT D BEAM - FLANGE CONNECTOR DETAILS
•"+7"
•"+9"
SHRINK GROUT
FILL WITH NON-
SECTION
#4 @ 6"
PLAN
3"
3"
#4 @ 6"
1"
2•
"
MIN.
1"+5"
1"+7"
SECTION
#4 @ 6"
FILL WITH UHPC
0"
0"
6"
4-#5
HOOKED BARS WITH NON-SHRINK GROUT STRAIGHT BARS WITH UHPC
3" MIN.
3" MIN. 3" MIN.
2•
"
2"
MI
N.
1"
MI
N.OBTAINED WITH STRAIGHT FORM
1" MINIMUM COVER CANNOT BE
OPTIONAL JOINT FORMING LINE IF
1"
MI
N.OBTAINED WITH STRAIGHT FORM
1" MINIMUM COVER CANNOT BE
OPTIONAL JOINT FORMING LINE IF
2"
MI
N.
GRINDING PLANE
" MAXIMUM JOINT DIFFERENTIAL - OVERLAY DETAIL21
" MAXIMUM JOINT DIFFERENTIAL - BARE DECK DETAIL21
OVERLAY
CAMBER DIFFERENTIAL DETAILS
AMPLITUDE (TYP.)
SURFACE. „" MINIMUM
EXPOSED AGGREGATE
AMPLITUDE (TYP.)
SURFACE.„" MINIMUM
EXPOSED AGGREGATE
AMPLITUDE (TYP.)
SURFACE.„" MINIMUM
EXPOSED AGGREGATE
2"
2"
OF THE JOINT WILL AFFECT THE BEAM SPACING.
SPECIFICATIONS. REFER TO THE PCI NORTHEAST DECK BULB TEE BEAM DETAILS FOR EXAMPLES. NOTE THAT THE WIDTH
A JOINT WITH NORMAL DECK CONCRETE. THE DESIGN OF THE JOINT SHOULD FOLLOW THE AASHTO LRFD BRIDGE DESIGN
8.THE DETAILS SHOWN ABOVE ARE BASED ON THE USE OF NON-SHRINK GROUTS AND UHPC. IT IS POSSIBLE TO DETAIL A
ACCOMMODATE VARIATIONS IN EXISTING FORMS.
7. THE DESIGNER SHOULD ALLOW THE FABRICATOR TO MAKE MINOR CHANGES TO THE DIMENSIONS OF THE SHEAR KEYS TO
SPECIFIED IN THE AASHTO LRFD SPECIFICATIONS.
EQUIVALENT TO A TENSION LAP SPLICE BASED ON A LAP EQUAL TO THE DEVELOPMENT LENGTH OF HOOKS IN TENSION AS
6. DESIGNERS ARE RESPONSIBLE FOR THE VERIFICATION OF THE DESIGN OF THIS JOINT. THIS DETAIL CAN BE CONSIDERED
5. EXPOSED AGGREGATE SURFACE OF THE FACES OF THE KEYS IS RECOMMENDED TO IMPROVE GROUT BOND.
6000 PSI. THE GROUT MAY BE EXTENDED WITH AGGREGATE.
4. CLOSURE POUR MATERIAL IN LEFT DETAIL TO BE A NON SHRINK MIX THAT HAS A MINIMUM COMPRESSIVE STRENGTH OF
APPROVED BY THE ENGINEER.
ABLE TO ACCOMMODATE DIFFERENTIAL CAMBER. FORM SUPPORTS SHOULD NOT PENETRATE THROUGH TOP OF POUR UNLESS
3. METHOD OF FORMING CLOSURE POUR TO BE DETERMINED BY THE CONTRACTOR. THE FORMS NEED TO BE REMOVABLE AND
WITHIN THE FLANGE IN ACUTE CORNERS TO PRODUCE A SQUARE PROJECTION.
2. FOR SKEWED BRIDGES, PLACE CONNECTOR REINFORCING PERPENDICULAR TO BEAM EDGE. BEND CONNECTOR REINFORCING
NOTES: 1. CONNECTOR REINFORCING TO BE PLACED ALONG THE ENTIRE SPAN WITH 6" SPACING.
PRECAST FACILITY
CAST IN THE FIELD OR AT THE
CAST-IN-PLACE CONCRETE CURB
OVERHANG (IF DESIRED)
DRIP EDGE
NEXT BEAM
WEARING SURFACE
MEMBRANE WATERPROOFING
DETAILS AS PER STATE STANDARDS
WATERPROOFING MEMBRANE CURB
ALL REINFORCING IN BEAM NOT SHOWN.
ANCHOR BOLTS NOT SHOWN IN CURB.
THIS DETAIL CAN BE MODIFIED FOR ANY TYPICAL PARAPET SHAPE INCLUDING F SHAPE PARAPETS.
STEEL RAIL IN CURB SHOWN, OTHER PARAPETS SIMILAR.
NOTES: THIS DETAIL IS SCHEMATIC. ACTUAL DETAIL WOULD NEED TO BE FULLY DESIGNED.
NEXT D BEAM - BARRIER/RAIL ATTACHMENT
JOINT SEAL
VERTICALS
ADDITIONAL END ZONE
BURSTING STEEL IN END ZONE
SHEAR REINFORCEMENT USED FOR
ANCHOR REAR FACE VERTICALS IN MIDDLE OF STRAND GRID
(AASHTO LRFD 5.10.10.1)
BURSTING ZONE = d/4
STATE STANDARDS)
BLOCKOUT (SEE
ELEVATION - STEM ENDEND ELEVATION - STEM ENDPLAN - SKEWED END
SEE NOTE 3
BOTTOM OF TOP FLANGE.
#4 BARS PLACED AT
SKEW OF 20 DEGREES
RECOMMENDED MAX.
REINFORCING. SEE NOTE 1
BURSTING ZONE VERTICAL
ZONE IF REQUIRED
BUNDLED IN END
STIRRUPS MAY BE
NEXT D BEAM - END REINFORCING DETAILS
AND HANDLING. SEE DETAILS ON SHEET 08
TO CONTROL CRACKING DUE TO SHIPPING
J BARS MAY BE ADDED TO SKEWED BEAMS
STANDARD STIRRUP
1"
THE REQUIREMENTS SPECIFICED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS.
CONTROL, NOT PREVENTION. IF TOP LONGITUDINAL REINFORCING IS USED, THE ALLOWABLE TENSILE STRESSES MUST STILL BE LIMITED TO THE
DESIGNED IN ACCORDANCE WITH THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS. THIS REINFORCING IS FOR CRACK WIDTH AND LENGTH
EXCEED 200 PSI. THESE BARS ARE USED TO CONTROL TRANSVERSE CRACKING IN THE TOP FLANGE AT RELEASE. THIS REINFORCING SHALL BE
5. THE DESIGNER SHALL DETAIL ADDITIONAL TOP LONGITUDINAL REINFORCING IN THE TOP FLANGE AT BEAM ENDS IF THE TOP FIBER STRESSES
4. BEAMS MAY BE FABRICATED WITH HIGHER SKEWS, HOWEVER ADDITIONAL CRACKING IN THE TOP FLANGE MAY OCCUR.
THE SHOP AS A SECONDARY POUR CAN HELP TO PREVENT THE GROWTH OF THESE CRACKS DURING SHIPPING AND ERECTION.
THE TWO J SHAPED BARS SHOWN MAY BE COMBINED INTO ONE INVERTED U SHAPED BAR. THE USE OF A SEMI-INTEGRAL BACKWALL THAT IS CAST IN
FLANGE / BEAM STEM INTERFACE RUNNING PARALLEL TO THE STEM. #5 J BARS ARE USED TO SUPPLEMENT THIS REINFORCING.
COMMON FORM OF POTENTIAL CRACKING IN THIS AREA IS A SERIES OF VERTICAL HAIRLINE CRACKS THROUGH THE INSIDE RADIUS OF THE TOP
3. PLACE 2-#4 BARS AT THE BEAM END IN THE TOP FLANGE TO CONTROL TOP FLANGE END CRACKING DURING RELEASE AND HANDLING. THE MOST
BE PLACED IN AREAS WHERE DEBONDING IS TERMINATED.
2. THE AMOUNT OF SPLITTING REINFORCING MAY BE REDUCED BY DEBONDING STRAND IN THIS AREA. ADDITIONAL SPLITTING REINFORCING SHOULD
END VERTICAL BARS MAY NOT BE NECESSARY DEPENDING ON THE DESIGN.
1. THE BARS SHOWN ARE APPROXIMATELY THE MAXIMUM NUMBER THAT CAN BE FIT WITHIN THE NEXT 28 D BEAM. SOME OR ALL OF THESE ADDITIONAL
NOTES:
NE
XT F B
EA
M - S
UBSTR
UC
TU
RE
DET
AIL
S
NE
XT 11
RE
VISIO
NS
DES
CRIP
TIO
ND
ATE
NO.
SH
EET:
TM
PCI
DIS
CLAIM
ER:
PR
EC
AST/P
RESTR
ESSE
D
CO
NC
RETE IN
STIT
UTE
NO
RT
HE
AST
WW
W.P
CIN
E.O
RG
NO
RT
HE
AST E
XTR
EM
E TEE (N
EXT)
BE
AM
DET
AIL
S
thro
ugh this guidelin
e. If such services are re
quired, please seek an appro
priate professio
nal.
Northeast is supplying inform
ation only. P
CI Northeast is not re
ndering engineering or other professio
nal s
ervices
or da
mages arising out of this inform
ation. P
CI Northeast has publis
hed this work with the understa
nding that P
CI
sources belie
ved to be relia
ble. P
CI Northeast or its me
mbers
hips shall not be responsible for any errors, o
missio
n
The details sho
wn are guidelin
es and should not be considere
d sta
ndards. T
he inform
ation has been obtained fro
m
ISS
UE
DATE: 03 / 10 / 15
REINFORCING NOT SHOWN
REINFORCED DECK SLAB
END DIAPHRAGM
#5 (TYP)
APPROACH SLAB
CLOSED CELL FOAM
BELOW DIAPHRAGM
EXPANDED POLYSTYRENE FOAM
DIAPHRAGM
REINFORCING INTO
EXTEND STRAND AND/OR
2. INTERMEDIATE DIAPHRAGMS ARE NOT REQUIRED.
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.
1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTAION STANDARDS FOR TYPE 1
NOTES:
CANTILEVER ABUTMENT
NEXT F - SAMPLE END DIAPHRAGM DETAIL
REINFORCING NOT SHOWN
REINFORCED DECK SLAB
SLAB
PRECAST APPROACH
CONNECTION TO BACKWALL
REINFORCING TO PROVIDE
EXTEND STRAND AND/OR
ABUTMENT STEM
NOTE: ALL REINFORCEMENT NOT SHOWN
IN PLANT OR FIELD CAST.
SEMI-INTEGRAL BACKWALL. SECONDARY POUR
COMNPRESSIBLE MATERIAL
CLOSED CELL FOAM OR OTHER
ELASTOMERIC BEARING
NEXT F - SAMPLE SEMI-INTEGRAL ABUTMENT SECTION
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.
1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 2
NOTES:
STRAND (TYP.)
EXTEND PRESTRESSING
EXPANDED POLYSTYRENE
ELASTOMERIC BEARING (TYP)
BEAM END (TYP)
DOWEL PIN IF REQUIRED BY DESIGN
PIER CAP
TRANSVERSE DECK REINFORCING NOT SHOWN
CONTINUOUS DECK REINFORCING
NEXT F - SAMPLE PIER CONTINUITY DETAIL
CRACKING OF THE END DIAPHRAGM.
DECK AND CLOSURE POUR CONCRETE IN ORDER TO ALLOW FOR BEAM ROTATION WITHOUT
2. THE DESIGNER SHOULD SPECIFY THE TIMING AND SEQUENCE OF THE PLACEMENT OF THE
1. THE DETAILS SHOWN ARE SCHEMATIC. REFER TO STATE STANDARDS FOR SPECIFIC DETAILS.
NOTES:
CLOSURE POUR
REINFORCING NOT SHOWN
REINFORCED DECK SLAB
CLOSURE POUR
PILE
PRECAST INTEGRAL ABUTMENT
SLAB
PRECAST APPROACH
REINFORCING BETWEEN STEMS
CONNECTION TO ABUTMENT
POSITIVE MOMENT
REINFORCING TO PROVIDE
EXTEND STRAND AND/OR
CORRUGATED METAL PIPE VOID
FACILITATE CONCRETE PLACEMENT AND PREVENT VOIDS
4" DIAMETER BLOCKOUTS IN TOP FLANGE TO
NEXT F - SAMPLE INTEGRAL ABUTMENT SECTION
2. A PRECAST PIECE SIMILAR TO THE BACKWALL PIECE CAN BE USED AT THE ENDS OF THE ABUTMENT ALSO.
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.
1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 2
NOTES:
NE
XT E
BE
AM - S
UBSTR
UC
TU
RE
DET
AIL
S
NE
XT 12
RE
VISIO
NS
DES
CRIP
TIO
ND
ATE
NO.
SH
EET:
TM
PCI
DIS
CLAIM
ER:
PR
EC
AST/P
RESTR
ESSE
D
CO
NC
RETE IN
STIT
UTE
NO
RT
HE
AST
WW
W.P
CIN
E.O
RG
NO
RT
HE
AST E
XTR
EM
E TEE (N
EXT)
BE
AM
DET
AIL
S
thro
ugh this guidelin
e. If such services are re
quired, please seek an appro
priate professio
nal.
Northeast is supplying inform
ation only. P
CI Northeast is not re
ndering engineering or other professio
nal s
ervices
or da
mages arising out of this inform
ation. P
CI Northeast has publis
hed this work with the understa
nding that P
CI
sources belie
ved to be relia
ble. P
CI Northeast or its me
mbers
hips shall not be responsible for any errors, o
missio
n
The details sho
wn are guidelin
es and should not be considere
d sta
ndards. T
he inform
ation has been obtained fro
m
ISS
UE
DATE: 03 / 10 / 15
REINFORCING NOT SHOWN
REINFORCED DECK SLAB
END DIAPHRAGM
#5 (TYP)
APPROACH SLAB
CLOSED CELL FOAM
BELOW DIAPHRAGM
EXPANDED POLYSTYRENE FOAM
DIAPHRAGM
REINFORCING INTO
EXTEND STRAND AND/OR
ELASTOMERIC BEARING
2. INTERMEDIATE DIAPHRAGMS ARE NOT REQUIRED.
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.
1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 1
NOTES:
CANTILEVER ABUTMENT
NEXT E - SAMPLE END DIAPHRAGM DETAIL
REINFORCING NOT SHOWN
REINFORCED DECK SLAB
SLAB
PRECAST APPROACH
CONNECTION TO BACKWALL
REINFORCING TO PROVIDE
EXTEND STRAND AND/OR
ABUTMENT STEM
COMNPRESSIBLE MATERIAL
CLOSED CELL FOAM OR OTHER
ELASTOMERIC BEARING
NEXT E - SAMPLE SEMI-INTEGRAL ABUTMENT SECTION
NOTE: ALL REINFORCEMENT NOT SHOWN
IN PLANT OR FIELD CAST.
SEMI-INTEGRAL BACKWALL. SECONDARY POUR
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.
1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 2
NOTES:
STRAND (TYP.)
EXTEND PRESTRESSING
EXPANDED POLYSTYRENE
ELASTOMERIC BEARING (TYP)
BEAM END (TYP)
DOWEL PIN IF REQUIRED BY DESIGN
PIER CAP
TRANSVERSE DECK REINFORCING NOT SHOWN
CONTINUOUS DECK REINFORCING
NEXT E - SAMPLE PIER CONTINUITY DETAIL
CRACKING OF THE END DIAPHRAGM.
DECK AND CLOSURE POUR CONCRETE IN ORDER TO ALLOW FOR BEAM ROTATION WITHOUT
2. THE DESIGNER SHOULD SPECIFY THE TIMING AND SEQUENCE OF THE PLACEMENT OF THE
1. THE DETAILS SHOWN ARE SCHEMATIC. REFER TO STATE STANDARDS FOR SPECIFIC DETAILS.
NOTES:
CLOSURE POUR
REINFORCING NOT SHOWN
REINFORCED DECK SLAB
CLOSURE POUR
PILE
PRECAST INTEGRAL ABUTMENT
SLAB
PRECAST APPROACH
REINFORCING BETWEEN STEMS
CONNECTION TO ABUTMENT
POSITIVE MOMENT
REINFORCING TO PROVIDE
EXTEND STRAND AND/OR
CORRUGATED METAL PIPE VOID
FACILITATE CONCRETE PLACEMENT AND PREVENT VOIDS
4" DIAMETER BLOCKOUTS IN TOP FLANGE TO
NOTE: ALL REINFORCING NOT SHOWN
NEXT E - SAMPLE INTEGRAL ABUTMENT SECTION
2. A PRECAST PIECE SIMILAR TO THE BACKWALL PIECE CAN BE USED AT THE ENDS OF THE ABUTMENT ALSO.
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.
1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 2
NOTES:
NE
XT
D
BE
AM - S
UBSTR
UC
TU
RE
DET
AIL
S
NE
XT 13
RE
VISIO
NS
DES
CRIP
TIO
ND
ATE
NO.
SH
EET:
TM
PCI
DIS
CLAIM
ER:
PR
EC
AST/P
RESTR
ESSE
D
CO
NC
RETE IN
STIT
UTE
NO
RT
HE
AST
WW
W.P
CIN
E.O
RG
NO
RT
HE
AST E
XTR
EM
E TEE (N
EXT)
BE
AM
DET
AIL
S
thro
ugh this guidelin
e. If such services are re
quired, please seek an appro
priate professio
nal.
Northeast is supplying inform
ation only. P
CI Northeast is not re
ndering engineering or other professio
nal s
ervices
or da
mages arising out of this inform
ation. P
CI Northeast has publis
hed this work with the understa
nding that P
CI
sources belie
ved to be relia
ble. P
CI Northeast or its me
mbers
hips shall not be responsible for any errors, o
missio
n
The details sho
wn are guidelin
es and should not be considere
d sta
ndards. T
he inform
ation has been obtained fro
m
ISS
UE
DATE: 03 / 10 / 15
REINFORCING NOT SHOWN
REINFORCED DECK SLAB
APPROACH SLAB
CLOSED CELL FOAM
DIAPHRAGM
AROUND BEARINGS AND BELOW
EXPANDED POLYSTYRENE FOAMEND TO SUPPORT DIAPHRAGM
REINFORCING FROM BEAM
EXTEND STRAND AND/OR
END DIAPHRAGM
CAST-IN-PLACE CONCRETE
FOR FLOW OF CONCRETE
BLOCK OUT TOP FLANGE TO ALLOW
CANTILEVER ABUTMENT
NEXT D - SAMPLE END DIAPHRAGM DETAIL
2. INTERMEDIATE DIAPHRAGMS ARE NOT REQUIRED.
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.
1. THESE DETAILS ARE SIMILAR TO MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 1
NOTES:
REINFORCING NOT SHOWN
REINFORCED DECK SLAB
SLAB
PRECAST APPROACH
CONNECTION TO BACKWALL
REINFORCING TO PROVIDE
EXTEND STRAND AND/OR
ABUTMENT STEM
COMNPRESSIBLE MATERIAL
CLOSED CELL FOAM OR OTHER
ELASTOMERIC BEARING
NOTE: ALL REINFORCEMENT NOT SHOWN
NEXT D - SAMPLE SEMI-INTEGRAL ABUTMENT SECTION
NOTE: ALL REINFORCEMENT NOT SHOWN
IN PLANT OR FIELD CAST.
SEMI-INTEGRAL BACKWALL. SECONDARY POUR
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.
1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 2
NOTES:
STRAND (TYP.)
EXTEND PRESTRESSING
EXPANDED POLYSTYRENE
ELASTOMERIC BEARING (TYP)
BEAM END (TYP)
DOWEL PIN IF REQUIRED BY DESIGN
PIER CAP
TRANSVERSE DECK REINFORCING NOT SHOWN
CONTINUOUS DECK REINFORCING
MAY BE REQUIRED TO ADDRESS THIS CONDITION.
REMAINING STEM (WITHOUT THE FLANGE). DEBONDING OF STRAND OR ADDITIONAL REINFORCMENT
2. IF THE TOP FLANGE IS BLOCKED OUT AS SHOWN, THE ENGINEER SHOULD CHECK STRESSES IN THE
1. THE DETAILS SHOWN ARE SCHEMATIC. REFER TO STATE STANDARDS FOR SPECIFI DETAILS.
NOTES:
NEXT D - SAMPLE PIER CONTINUITY DETAIL
CLOSURE POUR
REINFORCING NOT SHOWN
REINFORCED DECK SLAB
CLOSURE POUR
PILE
PRECAST INTEGRAL ABUTMENT
SLAB
PRECAST APPROACH
REINFORCING BETWEEN STEMS
CONNECTION TO ABUTMENT
POSITIVE MOMENT
REINFORCING TO PROVIDE
EXTEND STRAND AND/OR
CORRUGATED METAL PIPE VOID
FACILITATE CONCRETE PLACEMENT AND PREVENT VOIDS
4" DIAMETER BLOCKOUTS IN TOP FLANGE TO
NOTE: ALL REINFORCING NOT SHOWN
NEXT D - SAMPLE INTEGRAL ABUTMENT SECTION
2. A PRECAST PIECE SIMILAR TO THE BACKWALL PIECE CAN BE USED AT THE ENDS OF THE ABUTMENT ALSO.
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.
1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 2
NOTES:
MIS
CELLA
NE
OU
S
NE
XT B
EA
M
DET
AIL
S
NE
XT 14
RE
VISIO
NS
DES
CRIP
TIO
ND
ATE
NO.
SH
EET:
TM
PCI
DIS
CLAIM
ER:
PR
EC
AST/P
RESTR
ESSE
D
CO
NC
RETE IN
STIT
UTE
NO
RT
HE
AST
WW
W.P
CIN
E.O
RG
NO
RT
HE
AST E
XTR
EM
E TEE (N
EXT)
BE
AM
DET
AIL
S
thro
ugh this guidelin
e. If such services are re
quired, please seek an appro
priate professio
nal.
Northeast is supplying inform
ation only. P
CI Northeast is not re
ndering engineering or other professio
nal s
ervices
or da
mages arising out of this inform
ation. P
CI Northeast has publis
hed this work with the understa
nding that P
CI
sources belie
ved to be relia
ble. P
CI Northeast or its me
mbers
hips shall not be responsible for any errors, o
missio
n
The details sho
wn are guidelin
es and should not be considere
d sta
ndards. T
he inform
ation has been obtained fro
m
ISS
UE
DATE: 03 / 10 / 15
11•"
FRONT ELEVATION
SIDE ELEVATION
BRIDGE SEAT
BEAM STEM
ELASTOMERIC BEARING
TAPERED INTERNAL SOLE PLATE
ELASTOMERIC BEARING
BEAM STEM
BRIDGE SEAT
MAX.
NARROW ELASTOMERIC BEARING DETAILS
5. TYPICAL KEEPER BLOCKS MAY BE USED BETWEEN THE STEMS FOR LATERAL RESISTANCE.
OF THE BEAM.
4. ELASTOMERIC SHIMS MAY BE USED TO PROPERLY SEAT BEAMS AND ADJUST THE ELEVATION OF THE TOP
3. BRIDGE SEAT AND BEARING MAY BE SLOPED TO MATCH THE CROSS SLOPE OF THE ROADWAY ABOVE.
THE BEARING. DETAILS FOR OTHER STATES WILL VARY.
TRANSPORTATION STANDARDS THAT INCLUDE THE USE OF AN EMBEDDED TAPERED STEEL SOLE PLATE IN
2. A TAPERED ELASTOMERIC BEARINGS IS SHOWN. THIS IS BASED ON MASSACHUSETTS DEPARTMENT OF
TO OR LESS THAN 11 1/2" WIDE.
1. THESE DETAILS ARE ONLY REQUIRED FOR NON-INTEGRAL SUBSTRUCTURES WITH BEARINGS THAT ARE EQUAL
NOTES:
BEAM STEM
ELASTOMERIC BEARING
BEAM STEM
ELASTOMERIC BEARING
FRONT ELEVATION
SIDE ELEVATION
BRIDGE SEAT
„" THICK NEOPRENE PADBEAM STEM
ELASTOMERIC BEARING
BEAM STEM
FRONT ELEVATION
SIDE ELEVATION
BRIDGE SEAT
„" THICK NEOPRENE PAD
ELASTOMERIC BEARING
3•"
INSERT SHOWN, OTHERS SIMILAR.
ANTICIPATED LOADS. LOOP FERRULE
DESIGNER TO SIZE INSERT BASED ON
PLACE INSERT BETWEEN STRAND ROWS.
NON-BOLTED OPTION
WIDE BEARING DETAILSBOLTED OPTION
WIDE BEARING DETAILS
WITH KEEPER TABS
BEVELED SOLE PLATE
WITH KEEPER TABS
BEVELED SOLE PLATE
WITH KEEPER TABS
BEVELED SOLE PLATE
WITH KEEPER TABS
BEVELED SOLE PLATE
TO STATE STANDARDS.
8. THE BOLTED PLATE OPTION SHOWN MAY BE MODIFIED TO PRODUCE A TYPICAL FIXED ELASTOMERIC BEARING. REFER
7. TYPICAL KEEPER BLOCKS MAY BE USED BETWEEN THE STEMS FOR LATERAL RESISTANCE.
THE SHIMS TO BE PLACED ON TOP OF OR BELOW THE BEARING.
TO PROPERLY SEAT BEAMS AND ADJUST THE ELEVATION OF THE TOP OF THE BEAM. BOLTED BEARINGS WOULD REQUIRE
6. ELASTOMERIC SHIMS MAY BE USED BETWEEN THE BOTTOM OF STEM AND TOP OF PLATE ON NON-BOLTED BEARINGS
HOLES IN THE BEAM FORM FOR THE INSERTS.
5. THE NON-BOLTED OPTION IS THE PREFERRED OPTION. USE OF THE BOLTED OPTION MAY REQUIRE THE DRILLING OF
OBTAINED BY BOLTING THE SIDE TABS INTO THE BEAM STEM (BOLTED OPTION).
4. THE SOLE PLATE CAN BE KEPT IN PLACE WITH FRICTION (NON-BOLTED OPTION). ADDITIONAL FIXITY CAN BE
3. BRIDGE SEAT AND BEARING ASSEMBLY SHOULD BE SLOPED TO MATCH THE CROSS SLOPE OF THE ROADWAY ABOVE.
2. BEARING MAY BE TAPERED IN LIEU OF THE BEVELED SOLE PLATE. SEE NARROW BEARING DETAILS ON THIS SHEET.
1. THESE DETAILS ARE ONLY REQUIRED FOR NON-INTEGRAL SUBSTRUCTURES.
NOTES:
INTO UNDERSIDE OF TOP FLANGE
OPTION 1: THREADED INSERT CAST
SAMPLE UTILITY SUPPORT DETAILS
NEXT F AND E BEAMS
SLEEVE CAST INTO TOP FLANGE
OPTION 2: THREADED ROD INSERTED THROUGH
5. THE DESIGN ENGINEER SHOULD DETAIL ANY ADDITIONAL REINFORCING REQUIRED TO RESIST THE UTILITY LOADS.
ACCEPTABLE.
4. THIS DETAIL SHOWS THE UTILITY SUPPORT BETWEEN AT THE CENTERLINE OF THE BEAM. OTHER LOCATIONS ARE
3. ONE TYPE OF UTILITY SHOWN, OTHER UTILITIES SIMILAR. REFER TO INDIVIDUAL UTILITY COMPANY DETAILS.
WITH THE STEM REINFORCING AND STRAND AND THE DIFFICULTIES OF SETTING ANCHORS PRIOR TO CASTING.
2. PLACEMENT OF ANCHORS IN THE STEM OF THE BEAM SHOULD BE AVOIDED DUE TO THE POTENTIAL FOR INTERFERENCE
POLICIES FOR OVERHEAD ANCHORING.
SLEEVES CAST INTO THE TOP FLANGE. OVERHEAD DRILLED-IN ANCHORS SHOULD NOT BE USED. REFER TO STATE
1. HANGER RODS FOR UTILITIES SHOULD BE ATTACHED TO THE BEAM BY MEANS OF CAST-IN-PLACE INSERTS OR THROUGH
NOTES:
UNDERSIDE OF TOP FLANGE
THREADED INSERT CAST INTO
SAMPLE UTILITY SUPPORT DETAILS
NEXT D BEAM
5. THE DESIGN ENGINEER SHOULD DETAIL ANY ADDITIONAL REINFORCING REQUIRED TO RESIST THE UTILITY LOADS.
ACCEPTABLE.
4. THIS DETAIL SHOWS THE UTILITY SUPPORT BETWEEN AT THE CENTERLINE OF THE BEAM. OTHER LOCATIONS ARE
3. ONE TYPE OF UTILITY SHOWN, OTHER UTILITIES SIMILAR. REFER TO INDIVIDUAL UTILITY COMPANY DETAILS.
INVESTIGATED.
CONSIDERED, HOWEVER THE POTENTIAL FOR INTERFERENCE WITH THE STEM REINFORCING AND STRAND SHOULD BE
2. PLACEMENT OF THE ANCHORS IN THE FLANGE IS PREFERRED. PLACEMENT OF ANCHORS IN THE STEM MAY BE
DRILLED-IN ANCHORS SHOULD NOT BE USED. REFER TO STATE POLICIES FOR OVERHEAD ANCHORING.
1. HANGER RODS FOR UTILITIES SHOULD BE ATTACHED TO THE BEAM BY MEANS OF CAST-IN-PLACE INSERTS. OVERHEAD
NOTES: