ngc gyp wall board

55
09 29 00/NGC ® Gypsum Board Systems 12 TH EDITION 09 29 00 57

Upload: seagull70

Post on 30-Nov-2015

47 views

Category:

Documents


0 download

DESCRIPTION

NGC

TRANSCRIPT

Page 1: Ngc Gyp Wall Board

09 29 00/NGC

®

Gypsum Board Systems

12TH EDITION

09

29

00

57

Page 2: Ngc Gyp Wall Board

58 NATIONAL GYPSUM BOARD PRODUCTS

Gold Bond® BRAND Gypsum Board Products

DESCRIPTION

Gold Bond BRAND GypsumBoard with tapered edgepermits smooth jointtreatment; surface takes anydecoration. Basicrecommendations: 1/2" board for single layer;3/8" board for 2-layer; 1/4"board is regular gypsumboard used in remodeling andfor sound control in doublelayer applications. Refer topage 65.

Gold Bond BRAND Fire-ShieldGypsum Board is manufac-tured with a type X core toachieve fire resistance ratingswhen used in recommendedsystems. Refer to page 66.

Gold Bond BRAND Fire-Shield CGypsum Board has a speciallyformulated type X core toachieve superior performancewhen used in specific firerated assemblies. May be usedin designs requiring Fire-ShieldGypsum Board (type X core).Refer to page 66.

Description Core Thickness/Type Width/Edge Lengths

Regular 1/4" (6.3 mm) 4' (1219 mm) 6' (1828 mm)3/8" (9.5 mm) Square thru1/2" (12.7 mm)* or 16' (4876 mm)

Tapered

Type X 5/8" (15.9 mm) FSW* 4' (1219 mm) 6' (1828 mm)Square thru

or 16' (4876 mm)Tapered

Type X 1/2" (12.7 mm) FSW-C 4' (1219 mm) 6' (1828 mm)Square thru

or 16' (4876 mm)Tapered

Type X 5/8" (15.9 mm) FSW-C 4' (1219 mm) 8' (2438 mm)Square thru

or 14' (4267 mm)Tapered

National Gypsum Companyfeatures a wide variety ofgypsum board productsand accessories includingregular gypsum board, Fire-Shield fire resistant board,1/4" High Flex GypsumBoard, 1/2" High StrengthCeiling Gypsum Board, Hi-Impact Gypsum Board,Gridstone Ceiling Boards,Gypsum Sheathing, Fire-Shield Shaftliner, DurasanPrefinished Gypsum Board,Exterior Soffit Board, andJoint Treatment products.

Our concentration isn’t onbuilding products alone,however. At the NationalGypsum Research andTesting Center, we developcomplete construction sys-tems. In such systems,products are evaluatedtogether as complete build-ing assemblies–walls, parti-tions, floors and ceilings.

We have included in this sec-tion details and applicationinstructions for many ofthose assemblies: SteelFrame Partitions, SteelFrame Ceilings/FurringChannels or Studs, Wood

Frame Wall and Ceilings,Gypsum Board Over FoamInsulated Masonry andSolid Laminated Partitions.

Before a National GypsumSystem is released to thebuilding industry, it is thor-oughly tested, and results arecorrelated and charted tomake it easier for the builderor specifier to match a sys-tem to their needs or to thebuilding codes.

The drywall construction sys-tems referred to in this cata-log are designed primarilywith materials manufac-tured by National Gypsum

Company. Substitution ofany product or otherbrands in a tested system is not recommended.

Field installation of tested sys-tems must be identical tolaboratory installation toproduce optimum perfor-mance of these systems.Performance tests are con-ducted in accordance withaccepted national stan-dards under controlled lab-oratory conditions to mini-mize variances and to per-mit comparison of testresults with all types of sys-tems, similar and dissimilar.

1/2" x 8' T

GOLD BOND ® BRAND WALLBOARD

1/2" x 8'

GOLD BOND ® BRAND WALLBOARD

1/2" x 8

GOLD BOND ® BRAND WALLBOARD

1/2" x 8

GOLD BOND ® BRAND WALLBOARD

1/2" x

GOLD BOND ® BRAND WALLBOARD

1/2"

GOLD BOND ® BRAND WALLBOARD

1/2

GOLD BOND ® BRAND WALLBOARD

1/

GOLD BOND ® BRAND WALLBOARD

* Available with Foil Backing. Refer to page 86.Reference www.nationalgypsum.com for fire safety information.

Gold Bond BRAND XP GypsumBoard is designed to provideextra protection against moldand mildew compared to stan-dard gypsum board products.Tapered edge permits smoothjoint treatment. Refer to page70.

Regular 1/2" (12.7 mm) 4' (1219 mm) 8' (2438 mm)Square 10' (3048 mm)

or 12' (3657 mm)Tapered

Note: 5/8" Fire-Shield gypsum board availablein 54" widths.

Note: 1/2" gypsum board available in 54" widths.

Page 3: Ngc Gyp Wall Board

59NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

Gold Bond BRAND Kal-KorePlaster Base is a tapered edgegypsum board plastering basehaving a blue absorptive facepaper surface designed topermit rapid trowelapplication and strong bondof veneer or conventionalgypsum plaster. Refer topage 45.

Description Core Thickness/Type Width/Edge Lengths

Regular 3/8" (9.5 mm) 4' (1219 mm) 8' (2438 mm)1/2" (12.7 mm) Square thru

or 16' (4876 mm)Tapered

Type X 1/2" (12.7 mm) FSK-C 4' (1219 mm) 8' (2438 mm)5/8" (15.9 mm) FSK Square thru

or 16' (4876 mm)Tapered

1/2" x 8' TE

KAL-KORE ® BRAND PLASTER BASE

1/2" x 8' T

KAL-KORE ® BRAND PLASTER BASE

1/2" x 8' T

KAL-KORE ® BRAND PLASTER BASE

1/2" x 8

KAL-KORE ® BRAND PLASTER BASE

1/2" x 8

KAL-KORE ® BRAND PLASTER BASE

1/2" x

KAL-KORE ® BRAND PLASTER BASE

1/2" x

KAL-KORE ® BRAND PLASTER BASE

1/2"

KAL-KORE ® BRAND PLASTER BASE

Gold Bold BRAND Sta-SmoothGypsum Board, used withProForm BRAND Sta-Smooth JointCompound, forms a drywallsystem offering maximum jointstrength. Two edgeconfigurations provide relief onjoint deformities. The roundedge configuration solves jointdeformity problems caused bytwisted framing, damaged boardedges, poor alignment andextremes in humidity andtemperature. Refer to page 67.

Regular 1/2" (12.7 mm) 4' (1219 mm) 6' (1828 mm)Sta-Smooth thru

16' (4876 mm)

Type X 5/8" (1519 mm) FSW 4’ (1219 mm) 8' (2438 mm)Sta-Smooth thru

16' (4876 mm)

Type X 1/2" (12.7 mm) FSW-C 4' (1219 mm) 6' (1828 mm)Sta-Smooth thru

16' (4876 mm)

1/2" x 12'

STA-SMOOTH ® BRAND WALLBOARD

1/2" x 12

STA-SMOOTH ® BRAND WALLBOARD

1/2" x 12

STA-SMOOTH ® BRAND WALLBOARD

1/2" x 1

STA-SMOOTH ® BRAND WALLBOARD

1/2" x

STA-SMOOTH ® BRAND WALLBOARD

1/2" x

STA-SMOOTH ® BRAND WALLBOARD

1/2"

STA-SMOOTH ® BRAND WALLBOARD

1/2

STA-SMOOTH ® BRAND WALLBOARD

Type X 5/8" (15.9 mm) FSW-3 4' (1219 mm) 8' (2438 mm)Square thru

or 12' (3657 mm)Tapered

Type X 1/2" (12.7 mm) FSMR-C 4' (1219 mm) 8' (2438 mm)Square thru

or 12' (3657 mm)Tapered

Type X 5/8" (15.9 mm) FSMR-C 4' (1219 mm 4' (1219 mm)Square thru

or 12' (3657 mm)Tapered

Gold Bond BRAND XP Fire-ShieldGypsum Board is manufac-tured with a fire resistive type Xgypsum core and is designed toprovide extra protection againstmold and mildew. Refer topage 70.

Gold Bond BRAND XP Fire-Shield CGypsum Board has a speciallyformulated type X gypsum coreto achieve superior fire resis-tance performance and isdesigned to provide extra pro-tection against mold andmildew. Refer to page 70.

Note: 1/2" regular Sta-Smooth gypsum boardavailable in 54" widths.

Note: 1/2" regular Kal-Kore plaster base availablein 54" widths.

09 29 00/NGC

Gold Bond BRAND GypsumSheathing is used as an underlayment onexterior walls. Finishmaterials are applied withfasteners through sheathinginto studs or furring strips.Refer to page 28.

Regular 1/2" (12.7 mm) 4' (1219 mm) 8' (2438 mm)Square 9' (2743 mm)

10' (3048 mm)

Type X 5/8" (15.9 mm) FSW-3 4' (1219 mm) 8' (2438 mm)Square 9' (2743 mm)

10' (3048 mm)

1/2" x 8' TE

GOLD BOND® BRAND JUMBO SHEATHING

1/2" x 8' T

GOLD BOND® BRAND JUMBO SHEATHING

1/2" x 8' T

GOLD BOND® BRAND JUMBO SHEATHING

1/2" x 8

GOLD BOND® BRAND JUMBO SHEATHING

1/2" x 8

GOLD BOND® BRAND JUMBO SHEATHING

1/2" x

GOLD BOND® BRAND JUMBO SHEATHING

1/2"

GOLD BOND® BRAND JUMBO SHEATHING

1/2"

GOLD BOND® BRAND JUMBO SHEATHING

Page 4: Ngc Gyp Wall Board

Description Core Thickness/Type Width/Edge Lengths

60 NATIONAL GYPSUM BOARD PRODUCTS

Gold Bond BRAND Fire-ShieldShaftliner XP is used as acomponent in shaftwallsystems, area separationwalls and solid laminatedgypsum partitions. Theproduct has moisture/mold/mildew resistant purplepaper on both faces. Refer topage 74, 110, 124, and 140.

Type X 1" (25.4 mm) FSW 2' (610 mm) Custom CutBeveled 7' (2134 mm)Edges thru

14' (4267 mm)

Gold Bond BRAND Fire-ShieldShaftliner is used as acomponent in shaftwallsystems, in area separationwalls and in solid gypsumpartitions. The product hasmoisture resistant green paperon both faces. Refer to pages73, 110, 124 and 140.

Type X 1" (25.4 mm) FSW 2' (610 mm) Custom CutBeveled 7' (2134 mm)Edges thru

14' (4267 mm)

Gold Bond BRAND Exterior SoffitBoard is designed to provide,in a fire resistive gypsumceiling board, the extraresistance to moisture andsagging required to meetprotected outdoor conditions.Refer to page 71.

1/2" x 8' TE

GOLD BOND ® BRAND SOFFIT BOARD

1/2" x 8' T

GOLD BOND ® BRAND SOFFIT BOARD

1/2" x 8' T

GOLD BOND ® BRAND SOFFIT BOARD

1/2" x 8

GOLD BOND ® BRAND SOFFIT BOARD

1/2" x 8

GOLD BOND ® BRAND SOFFIT BOARD

1/2" x

GOLD BOND ® BRAND SOFFIT BOARD

1/2"

GOLD BOND ® BRAND SOFFIT BOARD

1/2"

GOLD BOND ® BRAND SOFFIT BOARD

Regular 1/2" (12.7 mm) 4' (1219 mm) 8' (2438 mm)Sta-Smooth thru

12' (3658 mm)

Type X 5/8" (15.9 mm) FSW 4' (1219 mm) 8' (2438 mm)Sta-Smooth thru

12' (3658 mm)

Gold Bond BRAND High FlexGypsum Board is specificallydesigned for radiusconstruction such as curvedwalls, archways andstairways. It can be used forboth concave and convexsurfaces. 1/4" High Flex istypically applied in doublelayers. Refer to page 75.

Regular 1/4" (6.3 mm) 4' (1219 mm) 8' (2438 mm)Eased thru

10' (3048 mm)

1/4" x 8' EE

HIGH FLEX ® BRAND WALLBOARD

1/4" x 8' E

HIGH FLEX ® BRAND WALLBOARD

1/4" x 8'

HIGH FLEX ® BRAND WALLBOARD

1/4" x 8

HIGH FLEX ® BRAND WALLBOARD

1/4" x 8

HIGH FLEX ® BRAND WALLBOARD

1/4" x

HIGH FLEX ® BRAND WALLBOARD

1/4"

HIGH FLEX ® BRAND WALLBOARD

1/4

HIGH FLEX ® BRAND WALLBOARD

Page 5: Ngc Gyp Wall Board

61NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGC

Description Core Thickness/Type Width/Edge Lengths

Gold Bond BRAND High StrengthCeiling Gypsum Board isdesigned to resist saggingequal to 5/8" gypsum board.Installed perpendicular toframing, span can be up to24" o.c. Can be decoratedwith spray textures and willsupport insulation. Refer topage 77.

Regular 1/2" (12.7 mm) 4' (1219 mm) 6' (1828 mm)Tapered thru

16' (4876 mm)

1/2" x 12' T

HIGH STRENGTH ™ BRAND CEILING BOARD

1/2" x 12'

HIGH STRENGTH ™ BRAND CEILING BOARD

1/2" x 12

HIGH STRENGTH ™ BRAND CEILING BOARD

1/2" x 12

HIGH STRENGTH ™ BRAND CEILING BOARD

1/2" x 1

HIGH STRENGTH ™ BRAND CEILING BOARD

1/2" x

HIGH STRENGTH ™ BRAND CEILING BOARD

1/2"

HIGH STRENGTH ™ BRAND CEILING BOARD

1/2

HIGH STRENGTH ™ BRAND CEILING BOARD

Regular 5/8" (15.9 mm) FSW 4' (1219 mm) 8' (2438 mm)Square thru

or 12' (3657 mm)Tapered

Type X 5/8" (15.9 mm) FSW-5 4' (1219 mm) 8' (2438 mm)thru

Tapered 12' (3657 mm)

Gold Bond BRAND Hi-Abuse XPFire-Shield Gypsum Board isdesigned for use in areas wheresurface durability andindentation resistance are majorconcerns. The product ismanufactured with a mold andfire resistive Type X gypsumcore encased in heavy smoothabrasion resistant, mold/mildewresistant purple paper on theface side and heavymold/mildew resistant linerpaper on the back side. Referto page 78.

Gold Bond BRAND Hi-Impact XPFire-Shield Gypsum Board isdesigned for use in areaswhere impact/penetrationresistance is a major concern.The product is manufacturedwith a mold, moisture and fireresistant Type X gypsum coreencased in heavy smoothabrasion resistant, moisture,mold/mildew resistant purplepaper on the face side andheavy mold/mildew resistantliner paper on the back side. Afiberglass mesh is embedded inthe board to provide additionalimpact/penetration resistance.Refer to page 81.

Gold Bond BRAND SoundbreakGypsum Board is anacoustically enhancedgypsum board used in thecontruction of high rated STCwall assemblies. This 5/8"thick gypsum board consistsof a layer of viscoelasticdamping polymersandwiched between twopieces of enhanced highdensity mold resistantgypsum board, providingconstrained layer damping.Refer to page 84.

Regular 5/8" (15.9 mm) 4' (1219 mm) 8' (2438 mm)Tapered thru

12' (3658 mm)

Page 6: Ngc Gyp Wall Board

62 NATIONAL GYPSUM BOARD PRODUCTS

Gridstone BRAND Hi-StrengthCeiling Panels have a non-combustible high strength sagresistant gypsum core with a 2-mil textured vinyl laminatesurface suited for interior orexterior application in exposedgrid systems. Refer to page 88.

Regular 5/16" (7.9 mm) 2' (610 mm) 2' (610 mm)2' (610 mm) 4' (1219 mm)

Square

Description Core Thickness/Type Width/Edge Lengths

Gridstone BRAND CleanRoomPanels are designed for areasrequiring high levels of aircleanliness for airborneparticulate. Boards are sealedon face, back and long edgeswith a 2-mil rigid vinyl filmand exposed edges are factorysealed with durable coatingproviding a completely sealedpanel. Refer to page 87.

Type X 1/2" (12.7 mm) FSW-G 2' (610 mm) 2' (610 mm)2' (610 mm) 4' (1219 mm)

Square

Gridstone BRAND Ceiling Panelshave a fire resistant Fire-Shield G, type X core with a2-mil textured vinyl laminatesurface suited for interior or exterior application inexposed grid systems. Refer to page 86.

Type X 1/2" (12.7 mm) FSW-G 2' (610 mm) 2' (610 mm)2' (610 mm) 4' (1219 mm)

Square

Page 7: Ngc Gyp Wall Board

63NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGC

METRIC CAPABILITIESThe Federal Government has

mandated that each federalagency make a transition tothe use of metric units inall federal procurement,grants and business-relatedactivities. NationalGypsum Company, incomplying with this order,provides a full line of gyp-sum board products in“hard” metric dimensionswith regard to width andlength. Standard boardofferings are made in thewidth of 1200 mm and alength of 3600 mm. Jobsize lengths are availableon a special order basisrequiring minimum ordersand extended lead times.Contact your localNational GypsumCompany representative forfurther information.Thickness of gypsum boardwill be “soft” converted tothe metric equivalent.

ENVIRONMENTALCONDITIONSMaintain a room temperature

of not less than 40˚F (4˚C)during application of gyp-sum board except whenadhesive is used for theattachment of gypsumboard. For the bonding ofadhesive, joint treatment,texturing, and decoration,the room temperature shallbe maintained at least at50˚F (10˚C) for 48 hoursprior to application andcontinuously thereafteruntil completely dry.

Note 1: Precaution–When atemporary heat source isused, the temperature shallnot exceed 95˚F (35˚C) inany given room or area.

Note 2: Precaution–Maintainadequate ventilation in theworking area during instal-lation and curing period.

Protect gypsum board productsfrom direct exposure to rain,snow, sunlight, or otherexcessive weather condi-tions.

GUIDELINES FORPREVENTION OF MOLDGROWTH ON GYPSUMBOARDGypsum board does not gen-

erate or support thegrowth of mold when it isproperly transported,stored, handled, installed,and maintained. However,mold spores are presenteverywhere and whenconditions are favorable,mold can grow on practi-cally any surface.Observing these guide-lines will help minimizethe potential for moldgrowth on gypsum board.Gypsum board must bekept dry to prevent thegrowth of mold.

Transportation and ReceivingGypsum board must be pro-

tected during transit with aweather-tight cover ingood condition.

Plastic shipping bags areintended to provided pro-tection during transit onlyand must be promptlyremoved upon arrival ofthe load. Failure toremove the shipping bagcan increase the likeli-hood of developing condi-tions favorable to thegrowth of mold.

Storage and HandlingGypsum board must be

stored in an area that pro-tects it from adverseweather conditions, con-densation, and other formsof moisture.

Job site conditions that canexpose gypsum board towater or moisture must beavoided.

Gypsum board must bedelivered to the job site asnear to the time it will beused as possible.

ApplicationProvisions must be made to

keep gypsum board drythroughout application.

Gypsum board that has visi-ble mold growth must notbe used.

Gypsum board on walls mustbe applied with a mini-mum 1/4" (6.35 mm) gapbetween the gypsumboard and the floor.

Gypsum board must not beapplied over buildingmaterials where condi-tions exist that are favor-able to mold growth.

Maintenance FollowingApplication

Essential elements of soundweather tight buildingenvelope must be properlymaintained, such as theroof, sealants, windows,etc.

Immediate and appropriateremediation measuresmust be taken as soon aswater leaks or condensa-tion sources are identified.

Routine cleaning and mainte-nance operations must beperformed so as to preventsaturation of the gypsumboard.

Additional Sources ofInformation

The following Web sites pro-vide information and rec-ommendations for treatingmold growth; other sitesalso provide similar sug-gestions.

California Indoor Air QualityProgram athttp://www.cal-iaq.org/iaqsheet.html

Federal EmergencyManagement Agency athttp://www.fema.gov/pdf/hazards/fststpbr.html

New York City Departmentof Health athttp://www.ci,nyc.ny.us/html/doh/html/epi/moldrpt1.html

U. S. EnvironmentalProtection Agency athttp://www.epa.gov/iedweb00/pubs/moldresources.html

GA-238, Copyright GypsumAssociation

LIMITATIONS

1. Maximum stud spacing forsingle layer application of1/2" and 5/8" gypsum boardis 24" o.c. If 3/8" gypsumboard is used, it must beapplied in two layers, withthe second layer adhesivelyapplied; 24" o.c. stud spac-ing may be used.

2. Where long, continuous runsof this wall system areemployed, control joints mustbe provided every 30' or less.

3. Where structural movementmay impose direct loads onthese systems, isolationdetails are required.

4. Partitions should not be usedwhere frequently exposed toexcessive moisture unless allsurfaces are waterproofed.

5. To prevent weakening dueto calcining, gypsum boardshould not be exposed totemperatures over 125˚F(52˚C) for extended periodsof time.

6. Gypsum board joints on sin-gle layer, or the face layeron two layer applications,shall not occur within 12" ofthe corners of door framesunless control joints areinstalled at the corners.

7. When gypsum board abutsconcrete floors, cut board toallow for 1/8" to 1/4" clear-ance between board andfloor to prevent potentialwicking.

Page 8: Ngc Gyp Wall Board

64 NATIONAL GYPSUM BOARD PRODUCTS

DESCRIPTION

Gold Bond® BRAND GypsumBoard comes standard withGridMarX™ guide marks,printed on the paper sur-face. These guide marksalign with standard build-ing dimensions and help toquickly identify fastenerlines for stud and joistframing. Using GridMarX,accurate cuts can be madewithout having to drawlines. GridMarX also assistwith quick identification ofnail/screw pattern.

GridMarX guide marks run themachine direction of theboard at five points in 4"increments. Marks runalong the edge in bothtapers and at 16", 24" and32" in the field of theboard. The marks cover

easily with no bleed-through using standardpaint products.

Vertical Application - In a ver-tical application, GridMarXserve as a guide mark tohelp identify the exactlocation of framing mem-bers behind the gypsumboard, eliminating theneed for field applied vertical lines.

Horizontal Application - In ahorizontal application,GridMarX serve as a reference mark to helpidentify the location offraming members behindthe gypsum board. (If fram-ing member is located 2" tothe right of the GridMarXat the top edge of theboard, it will be located 2"to the right down the faceof the board.)

DETAILS

GRIDMARX —VERTICAL WALL APPLICATION

Studs inexample are

24" o.c.

GridMarXspaced4" apart

GRIDMARX — HORIZONTAL WALLAND CEILING APPLICATION

GridMarXspaced4" apart

Studs in exampleare 16" o.c.

Represents a pipe or wiring

GOLD BOND® BRAND GRIDMARX®

Page 9: Ngc Gyp Wall Board

65NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGC

Fire and sound ratings forbuilding systems utilizinggypsum board are dependenton the core type andthickness of the gypsumboard, its application inconjunction with thecomponent parts, and themanner in which it isapplied.

Tests for fire resistance andsound transmission,performed by independentlaboratories, have resulted inspecific ratings for walls/partitions; floor/ceilingassemblies; shaftwalls,stairwells and areaseparation walls; andcolumns. For maximum fireresistance and sound control,double layer construction isgenerally recommendedsince the additional massfurther retards heat and noisepenetration.

Gypsum board can be installedto both metal and woodframing using nails, screwsor adhesives in combinationwith nails or screws. In manyinstances, the applicationwill dictate which fasteningmethod is appropriate.

Control joints may be necessaryto prevent cracking in thegypsum board facing ofdrywall systems, especiallyin areas where structuralelements such as slabs,columns or exterior wallscan bear directly on non-load-bearing partitions. Torelieve the stresses whichoccur as a result ofmovement induced bychanges in moisture,temperature or both, controljoints are required in bothpartitions and ceilings.

GYPSUM BOARDINSULATING PROPERTIESFor purposes of calculating

“U” values, the “C” factor for1" gypsum board is 1.2;Resistance “R” for 3/8" boardis .32; for 1/2" board .45; for5/8" board .56 and for 1"board .83.

WEIGHTS

1/4" Regular - 1.2 lbs/SF3/8" Regular - 1.2 lbs/SF1/2" Regular - 1.6 lbs/SF

RECOMMENDATIONS

Examine and inspect materialsto which gypsum board is tobe applied. Remedy alldefects prior to installation ofdrywall. Any defects in thefinished installation due tomisaligned framing or othercause will be theresponsibility of the workperformed under that sectionof the specification and suchdefects shall be remediedunder that section of thespecification.

Gypsum board shall be appliedfirst to ceiling at right anglesto framing members, then towalls. Boards of maximumpractical length shall be usedso that an absolute minimumnumber of end joints occur.Board edges shall be broughtinto contact with each otherbut shall not be forced intoplace.

Gypsum board joints atopenings shall be located sothat no end joint will align

with edges of opening unlesscontrol joints will beinstalled at these points. Endjoints shall be staggered, andjoints on opposite sides of apartition shall not occur onthe same stud.

Gypsum board shall be held infirm contact with the framingmember while fasteners arebeing driven. Fastening shallproceed from center portionof the board toward theedges and ends. Fastenersshall be set with the headsslightly below the surface ofthe board in a dimpleformed by the hammer orpower screwdriver. Careshall be taken to avoidbreaking the face paper ofthe gypsum board.Improperly driven nails orscrews shall be removed.

See page 63, EnvironmentalConditions and Limitations.

DESCRIPTION

Gold Bond® BRAND Gypsum Board

Gypsum Board is the name fora family of board productsconsisting of anoncombustible core,primarily of gypsum, with apaper surfacing on the face,back and long edges.*

The popularity of gypsum boardresults from a number offactors. First, it takes virtuallyany decoration – from paintor textures to vinyl andpaper laminates. It also lendsitself to creative shaping ofinterior surfaces, allowingthe maximum in designflexibility. Gypsum board isan economical alternative toother products. Because it islightweight, it is easy tohandle for speedyinstallation. With its naturalproperties, it is durable yeteasy to repair. In addition,gypsum board’s fireresistance and sound controlcapabilities furtherdemonstrate its desirabilityin building systems.

Ever conscious of theenvironmental challengeswe face in today’s world,National Gypsum producesits gypsum board with 100percent recycled paper onboth the face and back.

Gold Bond gypsum board isavailable with a variety ofedge configurations. For easyjoint finishing, the taperededge is preferred to providea monolithic surface. Wherejoints will be exposed,square or beveled edgesshould be considered.National Gypsum alsomanufactures gypsum boardwith proprietary edgeconfigurations made toaccommodate a variety ofwall systems and finishingtechniques.

*GA-216Fire and sound ratings for

building systems utilizinggypsum board aredependent on the core typeand thickness of the gypsum

SPECIFICATIONS

THE FOLLOWING PARAGRAPHS ARE FOR INSERTION INTO SECTIONS OF GENERIC SPECIFICATIONS OR GENERIC/PROPRIETARY SPECIFICATIONS COVERING GYPSUM BOARDPRODUCTS. THE NATIONAL GYPSUM PRODUCT NAME FOLLOWS THE GENERIC DESCRIPTION IN PARENTHESES.

PART 2 PRODUCTS 2.01 MATERIALSA. Regular Gypsum Board: A gypsum core board that is fire resistant and surfaced with paper on front/back and long edges and complies with

ASTM C 1396.1. Thickness: 1/4", 3/8", 1/2" (Gold Bond BRAND Gypsum Board) 3. Length: 6' through 16'.2. Width: 4'. 4. Edges: Square, Tapered, or Beveled Tapered (Sta-Smooth Edge).

PART 3 EXECUTION 3.01 INSTALLATIONA. General: In accordance with the manufacturer’s recommendations, National Gypsum Company “Gypsum Construction Guide.”

TECHNICAL DATA

Note: To achieve tighter bending radii, use Gold Bond 1/4" HighFlex Gypsum Board. See page 75 for additional information and1/4" High Flex minimum bending radii chart.

CURVED SURFACESTo apply gypsum board over a curved surface, place a stop at one end

of the board and then gently and gradually push on the other end,forcing the center against the framing until the curve is complete.Shorter radii than shown in the table may be obtained by moisten-ing the face and back papers of the board with water, stacking on aflat surface, and allowing the water to soak into the core for at leastone hour. When the board is dry it will regain its original hardness.

Gypsum board may be applied to curved surfaces in accordance withthe following:

GYPSUM BOARD BENDING RADII

Thickness Bending Lengthwise Bending Widthwise

1/4" (6.4 mm) 5'-0" (1524 mm) 15'-0" (4572 mm)3/8" (9.4 mm) 7'-6" (2286 mm) 25'-0" (7620 mm)1/2" (12.7 mm) *10'-0" (3048 mm)5/8" (15.9 mm) 15'-0" (4572 mm)

*Bending two layers of 1/4" (6.4 mm) board successively will permit a bendingradius shown for 1/4" (6.4 mm) board.

SURFACE BURNING CHARACTERISTICS(Fire Hazard Classification) Tested in accordance with ASTM E 84

Gypsum Gypsum DurasanBoard Sheathing All Standard Patterns

Flame Spread Index 15 20 25 or less

Smoke Developed 0 0 50 or less

Page 10: Ngc Gyp Wall Board

66

DESCRIPTION TECHNICAL DATA

SPECIFICATIONS

THE FOLLOWING PARAGRAPHS ARE FOR INSERTION INTO SECTIONS OFGENERIC SPECIFICATIONS OR GENERIC/PROPRIETARY SPECIFICATIONSCOVERING GYPSUM BOARD PRODUCTS. THE NATIONAL GYPSUMPRODUCT NAME FOLLOWS THE GENERIC DESCRIPTION IN PARENTHESES.

PART 2 PRODUCTS2.01 MATERIALS

A. Fire-Resistant Gypsum Board: A gypsum core gypsumboard with additives to enhance fire resistance of the coreand surfaced with paper on front, back, and long edgesand complying with ASTM C 1396, type X.1. Thickness: 1/2" (Gold Bond BRAND Fire-Shield C

Gypsum Board), 5/8" (Gold Bond BRAND Fire-ShieldGypsum Board), or 5/8" (Gold Bond BRAND Fire-Shield C Gypsum Board)

2. Width: 4'3. Length: 6' through 16'

(1/2" Fire-Shield C Gypsum Board,5/8" Fire-Shield Gypsum Board)

Length: 8' through 14'(5/8" Fire-Shield C Gypsum Board)

4. Edges: Square, Tapered, or Beveled Tapered (Sta-Smooth Edge)

PART 3 EXECUTION3.01 INSTALLATION

A. General: In accordance with the manufacturer’s recommendations, National Gypsum Company “Gypsum Construction Guide.”

RECOMMENDATIONS

Gold Bond® BRAND Fire-Shield®

Gypsum Board wasdeveloped to work incombination with otherproducts in an assembly toretard heat transfer throughthe assembly. Fire-Shieldgypsum boards are madewith cores formulated tooffer greater fire resistancethan regular gypsum board.Generically, these fireresistant boards that areused to delay heat transferto structural members aredesignated as “type X”products.

The Gypsum core of Fire-Shield Gypsum Board worksas a natural “sprinklersystem.” Gypsum naturally

SYSTEM BURNING CHARACTERISTICS

ASTM E84Flame Spread: 15Smoke Developed: 0

According to ASTM C 1396,the standard for gypsumboard, type X gypsumboard must provide at least:a one-hour fire resistancerating for 5/8" board, or a3/4-hour fire resistancerating for 1/2" boardapplied in a single layernailed on each face ofload-bearing wood framingmembers when tested inaccordance with therequirements of Methods ofFire Test of BuildingConstructions andMaterials (ASTMdesignation E 119).

Examine and inspect materialsto which gypsum board isto be applied. Remedy alldefects prior to installationof drywall. Any defects inthe finished installation dueto misaligned framing orother cause will be theresponsibility of the workperformed under thatsection of the specificationand such defects shall beremedied under thatsection of the specification.

Gypsum board shall beapplied first to ceiling atright angles to framingmembers, then to walls.Boards of maximumpractical length shall beused so that an absoluteminimum number of endjoints occur. Board edgesshall be brought intocontact with each other but shall not be forced into place.

contains about 21 percentwater. When the board isheated, the water in thecore begins to evaporateand is released as steam,retarding heat transfer. Fire-Shield gypsum boardremains noncombustible.However, as shrinkageoccurs because of the lossof water volume, cracksoccur which permitpassage of fire and heat. To lessen this process, Fire-Shield gypsum boardis formulated by addingnoncombustible fibers to the gypsum to helpmaintain the integrity ofthe core as water volume is lost while providinggreater resistance to heattransfer.

For additional fire protection,Gold Bond Fire-Shield Cproducts are formulatedwith a mineral coreadditive which expandswhen subjected to heatwhich aids in holding thegypsum board together.

Fire-Shield gypsum boardsalso can be used ascolumn protection,delaying the rapid transferof heat to reduce thelikelihood that structuralmembers will lose strengthand fail to carry theintended load.

FIRE RESISTANCE RATINGSFire resistance ratings

represent the results of tests on assemblies made up of specific materials in aspecific configuration. When selecting construction designs to meet certain fire resistance requirements, caution mustbe used to insure that each component of the assemblyis the one specified in the test. Further, precaution should be taken that assembly procedures are inaccordance with those of the tested assembly. (For copies of specific tests,call 1-800-NATIONAL.)

Gypsum board joints atopenings shall be locatedso that no end joint willalign with edges ofopening unless controljoints will be installed atthese points. End jointsshall be staggered, andjoints on opposite sides ofa partition shall not occuron the same stud.

Gypsum board shall be heldin firm contact with theframing member whilefasteners are being driven.Fastening shall proceedfrom center portion of theboard toward the edgesand ends. Fasteners shallbe set with the headsslightly below the surfaceof the gypsum board in adimple formed by thehammer or powerscrewdriver. Care shall betaken to avoid breaking theface paper of the gysumboard. Improperly drivennails or screws shall beremoved.

See page 63, EnvironmentalConditions andLimitations.

Gold Bond® BRAND Fire-Shield® Gypsum Board

WEIGHTS1/2" Type C - 1.9 lbs/SF5/8" Type X - 2.2 lbs/SF5/8" Type C - 2.2 lbs/SF

For fire safety information, go towww.nationalgypsum.com.

NATIONAL GYPSUM WALLBOARD PRODUCTS

Page 11: Ngc Gyp Wall Board

67NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGC

DETAILS

DESCRIPTION

TECHNICAL DATA

SURFACE BURNINGCHARACTERISTICS

ASTM E-84Flame Spread: 15Smoke Developed: 0

WEIGHTS

1/2" Regular - 1.6 lbs/SF5/8" Type X - 2.2 lbs/SF5/8" Type C - 2.2 lbs/SF

THE SECRET IS IN THE SHAPE OF THE JOINT AND THESTRENGTH OF THE COMPOUND

Standard tapered-beveled edge configuration.

Round edge configuration.

Easier Scheduling – Tapingwith Sta-Smooth Com -pounds and applying thefirst finishing coat, evenbefore the Sta-Smooth usedfor taping has dried, allowseasier job scheduling forthe drywall contractor andfinisher. This is particularlyadvantageous under slowdrying conditions.

The Sta-Smooth System produces a superior joint because theSta-Smooth Compounds are a hardening-type compound thatis not affected by humidity once it has hardened and dried. Italso maintains its hard core even with moisture added by theuse of the regular joint compounds for the finishing work. Sta-Smooth Compound firmly bonds the tape to the board and the board “V” edges to each other making a strong,rigidized joint.

Consult your local National Gypsum sales representative foredge configuration available in your market.

Gold Bond® BRAND Sta-Smooth® Gypsum Board

Sta-Smooth is a drywall system offering maximumjoint strength and easyapplication. It can be usedin any gypsum drywall system where conventionaltypes of gypsum board arerecommended. This system features Sta-SmoothBrand gypsum board with aunique edge. The two edgeconfigurations relieve jointdeformity problems causedby twisted framing,damaged gypsum boardedges, poor alignment andextremes in humidity andtemperature. Regular Sta-Smooth Boards areavailable in 1/2" thicknesses, 4' wide and incustomary gypsum boardlengths. The Sta-SmoothSystem is also composed ofProForm BRAND Sta-SmoothJoint Compounds, ahardening-type tapingcompound and regularGold Bond tape andfinishing compounds.

ADVANTAGESImproved Durability – The

Sta-Smooth System produces a smooth, flat,durable surface that relievesbeading, ridging and otherjoint deformity problems.

Greater Speed – All flat joints in the Sta-SmoothSystem are filled and tapedwith any Sta-SmoothCompounds all in one easyoperation, the same as conventional gypsum boardapplication methods. Sta-Smooth Compounds or regular compounds can beused to tape inside corners,cornerbeads, and spot fasteners. Regular ProFormfinishing compounds orSta-Smooth compounds areused for the remainingfinishing coats.

Easier Handling – Theimproved edge designs onSta-Smooth Boards makeshandling easier with greatercomfort to the hands.

No Special Equipment – Allconventional fasteners,adhesives, and gypsumboard application tools (T-squares, knives, etc.) can beused to apply Sta-SmoothBoards. Nothing new tobuy.

Alignment – Sta-Smoothboard with its unique edge(either configuration)allows for easy alignmentof the boards in the sameway as conventionaltapered edge board. Thetaper is scientificallydesigned to reducecrowned joints.

Stronger Bond – The bondingarea of the Sta-SmoothJoint Compounds areincreased with the “V”edge boards. The Sta-Smooth Joint Compoundused to bond the joint tapeand fill the joints is a hardening-type, high density material with low shrinkage characteristics.

Strength – The Sta-Smoothjoint shape and the jointcompound are developedto provide greater massand integral bond forincreased strength. Sta-Smooth Joint Compoundsadd considerable strengthwhich is unaffected by the amount of moisturenormally introduced into astructure that could causeridging or beading withconventional joint compounds.

Cost – If application techniques are followed asrecommended, the Sta-Smooth System should costno more and can cost considerably less than conventional gypsumboard drywall jointfinishing. The initialsavings are immediatelydemonstrated with reducedtravel time that results fromthis perfected 2-trip, 3-stepjoint finishing system.Future cost savings will berealized with reduced callbacks.

Better Butt Joints –Recommended with the Sta-Smooth System is animproved technique forproviding a smoother, flatter, stronger butt joint.Although this techniquecould be used in conventional drywall work and produce betterbutt joints, it is furtherimproved by the use of thehigh strength Sta-SmoothCompound.

Page 12: Ngc Gyp Wall Board

68 NATIONAL GYPSUM BOARD PRODUCTS

SPECIFICATIONSRECOMMENDATIONS

THE FOLLOWING PARAGRAPHS ARE FOR INSERTION INTO SECTIONS OF GENERICSPECIFICATIONS OR GENERIC/PROPRIETARY SPECIFICATIONSCOVERING GYPSUM BOARD PRODUCTS. THE NATIONAL GYPSUM PRODUCTNAME FOLLOWS THE GENERIC DESCRIPTION IN PARENTHESES.

PART 2 PRODUCTS2.01 MATERIALS

A. Gypsum Board: A gypsum core wall board surfaced with paper on front, back, and long edges and complying with ASTM C 1396 (Gold Bond BRAND Gypsum Board).1. Thickness: 1/2"2. Width: 4'3. Length: 6' through 16'4. Edge: Beveled Tapered (Sta-Smooth Edge)

B. Fire-Resistant Gypsum Board: A gypsum core wall board withadditives to enhance fire resistance of the core and surfaced with paper on front, back, and long edges and complying with ASTM C 1396, type X.1. Thickness: 1/2" (Gold Bond BRAND Fire-Shield C Gypsum Board), 5/8" (Gold Bond BRAND Fire-Shield Gypsum Board), or 5/8" (Gold Bond BRAND Fire-Shield C Gypsum Board)2. Width: 4'3. Length: 6' through 16'

(1/2" Fire-Shield C Gypsum Board,5/8" Fire-Shield C Gypsum Board)

Length: 8' through 14'(5/8" Fire-Shield C Gypsum Board)

4. Edge: Beveled Tapered (Sta-Smooth Edge)5. Edge: Rounded (Sta-Smooth Edge)

C. Exterior Gypsum Soffit Board: A gypsum core soffit board with additives to enhance the sag resistance of the core; surfaced with water repellent paper on front, back, and long edges; and complying with ASTM C 1396 (Gold Bond BRAND Exterior Soffit Board).

1. Thickness: 1/2"2. Width: 4'3. Length: 8' through 12'4. Edge: Beveled Tapered (Sta-Smooth Edge)

D. Fire-Resistant Exterior Gypsum Soffit Board: A gypsum core soffit board with additives to enhance the fire-resistance

and the sag resistance of the core; surfaced with water repellent paper on front, back, and long edges; and complying with ASTM C 1396, type X (Gold Bond BRAND Fire-Shield Exterior Soffit Board).1. Thickness: 5/8"2. Width: 4'3. Length: 8' through 12'4. Edge: Beveled Tapered (Sta-Smooth Edge)

PART 3 EXECUTION3.01 INSTALLATION

A. General: In accordance with the manufacturer’s recommendations, National Gypsum Company “Gypsum Construction Guide.”

Note: Sta-Smooth Gypsum Board may be used with any of theGypsum Drywall Systems described in this GypsumConstruction Guide.

All specifications for the application of gypsum board asdescribed in this literature may also serve for the applicationof Sta-Smooth Boards. Any deviation from thesespecifications is as indicated below.

A. BOARD APPLICATION: Position each Sta-Smooth Board sothat the long edges are in light contact with the edges of theprevious boards. All boards positioned to form butt jointsshould have a gap approximately 1/16" between the boardends. This spacing can be assured by driving 2 extra fastenersat the end of the board to act as temporary spacers beforeabutting the next board. When the boards are fastened inplace, drive the temporary spacers flush with surface. Whengypsum board is applied horizontally, recess all butt joints onthe job by shimming the face of the studs (or joists), on bothsides of the studs (or joists), on which the joint will fall. Theshim can be pressed paper, thickness of building felt or other suitable materials not to exceed 1/16" thickness and as wide asthe stud or joist. It should be 6" longer than the butt joint andapplied to the face of the stud or joist with staples or nailsallowing the shim to extend under the edge of the abuttingboards of gypsum board to assure that the board facingsremain on the same plane.

B. CORNERS AND OPENINGS: All exterior corners and allopenings that require joint treatment should receive protective reinforcement of ProForm Multi-Flex Tape Bead orSteel Cornerbead or Steel Casing Bead as required.

C. TREATMENT OF JOINTS*: All flat Sta-Smooth gypsum boardjoints are taped with ProForm BRAND Sta-Smooth Compounds,making sure that a sufficient amount of compound is forcedinto the “V” joint and spread under the tape to form a solidfoundation for the finishing coats.**

1. As soon as the Sta-Smooth Joint Compound used for taping hashardened, the first finishing coat can be applied even whenthe Sta-Smooth Compound is still wet.

2. When the first finishing coat is completely dry the second finishing coat can be applied. Any of the ProForm JointCompounds may be used for the finishing coats.

3. Sta-Smooth Joint Compounds are recommended for the firstcoat on nail or screw heads. Regular finishing compoundsmay be used for subsequent spotting of the fasteners. Sta-Smooth Compounds are also recommended for the first coaton cornerbead and followed by one or more finishing coatsas required of regular ProForm Joint or Topping Compounds.

4. The inside corners may be treated with any of the ProFormJoint Treatment Compounds recommended for taping. If atwo-trip joint treatment operation is planned, the inside corners are taped with Sta-Smooth Joint Compounds. Thiswill permit finishing one side of the inside corners the firstday. Cornerbead is treated with Sta-Smooth Compounds if atwo-trip operation is employed.

*Alternate Method: When mechanical tools are to be used for taping joints, Sta-Smooth Compounds are used to fill the “V”joint only. Other ProForm Joint Compounds are then used tobed the tape and finish the joints. (See page 69.)

**Sta-Smooth, Sta-Smooth HS and Sta-Smooth Lite JointCompounds are recommended for pre-fill or tape/bed coatoperations in the Sta-Smooth system.

See page 63, Environmental Conditions and Limitations.

Page 13: Ngc Gyp Wall Board

69NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGC

3. Second Finishing Coat

TAPING AND FINISHING WITH MECHANICAL TOOLSTaping – Taping tools such as the “banjo” and “hopper” types are recommended for

taping the flat joints with Sta-Smooth Compounds and the inside corners with ProFormregular joint compounds or with Sta-Smooth Compounds. Automatic taping tools arenot recommended for use with hardening-type compounds. Mechanical tools can beused for taping the inside corners when a ProForm regular joint compound is used.When automatic taping tools are used for taping the flat joints, the “V” formed by theedges of Sta-Smooth board on the flat joints and all spaces between the gypsum boardedges on butt joints are prefilled with Sta-Smooth Compounds and allowed to harden(30 minutes longer than the set time designated on the bag) prior to taping with aregular ProForm joint compound.

Finishing – Mechanical type finishing tools can be used in the normal manner for thefinishing operations of the Sta-Smooth System since conventional ProForm finishingcompounds are used.

MIXING INSTRUCTIONSProForm BRAND Sta-Smooth Compounds are available in 20, 45, 90 and 210 minute set

times. MIX NO MORE COMPOUND THAN CAN BE APPLIED IN THE DESIGNATEDSET TIME. Contact your National Gypsum Company Representative for availability. A plastic container is recommended because of its ease in cleaning between batches.Do not use a wood or aluminum bucket. Add the compound gradually to clean waterwhile stirring. Note: Use only fresh, clean water suitable for human consumption. Mix at the ratio of 13-14 pints of water to the 25 lb. bag. Mix the compound free oflumps with a mechanical mixer or by hand. Mechanical mixing is recommended.Allow to stand 5 minutes as a “wetting” period and remix to further improve theworking qualities. If a slightly thinner compound is desired, add an additional pint ofwater, or less, after the compound is thoroughly mixed.

INSTALLATION

APPLICATION AND FASTENINGSta-Smooth Boards may be nailed, screwed or adhesively applied to wood studs or

furring, or screwed or adhesively applied to steel studs or furring, using conventionaltype and length of fastener. All fasteners shall be applied a minimum of 3/8" (maximum 1/2") from the edges and ends of each board. Then treat the joints in three simple steps.

CONVENTIONAL TAPING AND FINISHING1. Fill Joint And Bed Tape SimultaneouslyAll flat gypsum board joints are to be filled and taped in one operation with ProForm

BRAND Sta-Smooth Compounds, using ProForm Paper Tape in the conventionalmanner. When Sta-Smooth HS tape is used, the self-adhering fiberglass mesh tape isfirmly pressed to the gypsum board, spanning the joints. Sta-Smooth Compounds canthen immediately be applied to the joints. The compound must be forced through thetape to fill the channel formed by the “V” edges of the Sta-Smooth gypsum board. Allinside corners may be taped using regular ProForm compounds. Sta-SmoothCompounds are used for the first coat on nail or screw heads and will decreaseproblems with fastener imperfections. Inside angles, first and second finishing coatsmay be done using regular ProForm joint compounds.

2. First Finishing CoatAs soon as the Sta-Smooth Compound used for taping has hardened, the first finishing

coat may be applied on the flat joints even before it is dry. Any ProFrom joint compound may be used for this operation. A second coat may be applied at this timeto nail or screw heads, one coat on cornerbead if Sta-Smooth Compound was used forthe first coat.

3. Second Finishing CoatAs soon as the compounds used for the previous steps have thoroughly dried, a second

finishing coat is applied to all flat joints using ProForm Joint Compound or ToppingCompound. A third coat is applied over nail or screw heads and on cornerbead asrequired. The unfinished side of the inside corners is also finished at this time.

STA-SMOOTH ROUND EDGE REQUIRES PRE-FILLING PRIOR TO BED & TAPINGApplication Instructions For Round Edge Sta-Smooth Gypsum Board1) Mix Sta-Smooth Joint Compound, Sta-Smooth Lite Joint Compound or Sta-Smooth HS

Joint Compound as per bag instructions. Care should be taken to mix no more compound than can be applied in the designated set time.

2) Pre-fill all joints formed by the abutting round edge Sta-Smooth Gypsum Boards withSta-Smooth Compound, Sta-Smooth Lite Joint Compound or Sta-Smooth HS JointCompounds using a conventional joint finishing knife. Fill joints, level and wipe offexcess compound to the lowest level of the taper, allowing enough room for embedding the tape. Allow prefill material to harden prior to application of tape andbed coat.

3) Finish joints in the normal manner.

Application And Fastening

1. Fill Joint And Bed TapeSimultaneously

2. First Finishing Coat

Page 14: Ngc Gyp Wall Board

70 NATIONAL GYPSUM BOARD PRODUCTS

RECOMMENDATIONSExposure to excessive or

continuous moisture andextreme temperatures shouldbe avoided. XP Gypsum Boardis not recommended where itwill be exposed to temperaturesexceeding 125˚F (52˚C) forextended periods of time.

Gold Bond® BRAND XP®

Gypsum Board panelsconsist of a fire-resistant,mold and moisture-resistant gypsum coreencased in heavymoisture/mold/mildewresistant, 100% recycledpurple paper on the faceand backsides. XP Gypsum Board wasdesigned to provide extraprotection against moldand mildew compared tostandard gypsum boardproducts. The face paper is folded around the longedges to reinforce andprotect the core, and theends are square-cut andfinished smooth. Longedges of panels aretapered. Tapered edgesallow joints to be treated inthe normal manner. Foroptimum mold andmildew resistance,National Gypsumrecommends ProFormBRAND XP Ready Mix orProForm BRAND Sta-Smooth/Sta-Smooth Litesetting compounds.

Gold Bond BRAND XP Fire-Shield® Gypsum Boardfeatures a type X core toprovide additional fireresistance ratings whenused in tested systems.

Gold Bond BRAND XP Fire-Shield C Gypsum BoardPanels have a speciallyformulated type X core toachieve superiorperformance when used inspecific fire-ratedassemblies where theweight and number ofgypsum board layers are aconcern.

DESCRIPTION

TECHNICAL DATA

Gold Bond® BRAND XP® Gypsum Board

FIRE RESISTANCE RATINGSFire resistance ratings represent

the results of tests on assemblies made up of specific materials in a specific configuration. Whenselecting constructiondesigns to meet certain fireresistance requirements, caution must be used to insure that each componentof the assembly is the onespecified in the test. Further,precaution should be takenthat assembly procedures arein accordance with those of the tested assembly.(For copies of specific tests,

SPECIFICATIONS

call 1-800-NATIONAL. Forfire safety information, seewww.nationalgypsum.com.)

MOLD AND MILDEWRESISTANCEXP Gypsum Board was

designed to provide extraprotection against moldand mildew compared tostandard gypsum boardproducts. When tested byan independent lab perASTM D3273 (“StandardTest Method forResistance to Growth ofMold on the Surface ofInterior Coatings in anEnvironmental Chamber”),XP Gypsum Boardachieved a score of 10,the best possible score forthis test.

The use of XP Gypsum Boardin actual installations maynot produce the sameresults as were achievedin controlled, laboratoryconditions. No materialcan be considered “mold-proof,” nor is it certainthat any material willresist mold or mildewindefinitely. When used inconjunction with gooddesign, handling andconstruction practices, XPGypsum Board canprovide increased moldresistance versus standardgypsum board products.As with any buildingmaterial, exposure duringhandling, storage, andinstallation, and afterinstallation is complete, isthe best way to avoid theformation of mold ormildew.

WEIGHTS1/2” Regular - 1.75 lbs/SF1/2” Type C - 1.95 lbs/SF5/8” Type X - 2.4 lbs/SFSURFACE BURNING

CHARACTERISTICSASTM E 84Flame spread: 15Smoke developed: 0

PART 2 PRODUCTSTHE FOLLOWING PARAGRAPHS ARE

FOR INSERTION INTO SECTIONSOF GENERIC SPECIFICATIONS ORGENERIC/PROPRIETARYSPECIFICATIONS COVERINGGYPSUM BOARD PRODUCTS. THENATIONAL GYPSUM PRODUCTNAME FOLLOWS THE GENERICDESCRIPTION IN PARENTHESES.

2.01 MATERIALSA. Mold-Resistant Gypsum

Board: A gypsum core wallpanel with additives toenhance the water resistanceof the core; surfaced withmoisture/mold/mildewresistant paper on front,back and long edges andcomplying with ASTM C 1396 (Gold Bond BRANDXP Gypsum Board).1. Thickness: 1/2”2. Width: 4'3. Length: 8', 10' or 12'4. Edges: Square or

Tapered5. Mold and Mildew

Resistance: Panel scoreof 10 when tested in accordance with ASTMD 3273

B. Fire-Resistant Mold andMildew-Resistant GypsumBoard: A gypsum core wallpanel with additives toenhance the fire resistanceand water resistance of thecore; surfaced withmoisture/mold/mildewresistant paper on front,back and long edges andcomplying with ASTM C 1396, type X.1. Thickness: 1/2” (Gold

Bond BRAND XP Fire-Shield C Gypsum Board),5/8” (Gold Bond BRANDXP Fire-Shield Gypsum Board,) 5/8” (Gold BondBrand XP Fire-Shield CGypsum Board.)

2. Width: 4'3. Length: 8', 10', or 12'4. Edges: Square or

Tapered5. Mold and Mildew

Resistance: Panel scoreof 10 when tested in accordance with ASTMD 3273

PART 3 EXECUTION3.01 INSTALLATION

A. General: In accordance with the manufacturer’srecommendations, NationalGypsum Company “GypsumConstruction Guide.”

MAXIMUM FRAMING SPACING - For Single Layer XP Gypsum Board

Gypsum Board Gypsum Board MaximumThickness Orientation to Framing Framing Spacing

Ceilings: 1/2" (12.7mm) Parallel 16" (406mm) o.c.1/2" (12.7mm) Perpendicular 24" (610mm) o.c.5/8" (15.9mm) Parallel 16" (406mm) o.c.5/8" (15.9mm) Perpendicular 24" (610mm) o.c.

Walls: 1/2" (12.7mm) Perpendicular or Parallel 24” (610mm) o.c.5/8” (15.9mm) Perpendicular or Parallel 24” (610mm) o.c.

NOTE: On ceilings to receive hand or spray applied, water based texture material,XP Gypsum Board products shall be applied perpendicular to framing.

XP Gypsum Board can be used asa tile backer board in dry areasor areas with limited waterexposure such as directlybehind tile in tub and showerareas.

XP Gypsum Board can beinstalled on the interior southface of exterior walls.

XP Gypsum Board should not beused as a backer boarddirectly behind tile in tub andshower areas.

XP Gypsm Board should not beused in areas subject toconstant and/or excessivemoisture and high humiditysuch as gang showers, saunas,steam rooms and swimmingpool enclosures. PermaBaseBRAND cement board isrecommended for these areas.

XP Gypsum Board must bestored off the ground andunder cover. Sufficient risersmust be used to ensuresupport for the entire length ofthe gypsum board to preventsagging.

XP Gypsum Board must be keptdry to minimize the potentialfor mold growth. Adequatecare should be taken whiletransporting, storing, applyingand maintaining gypsumboard. For additionalinformation, refer to theGypsum Associationpublication, “Guidelines forthe Prevention of MoldGrowth on Gypsum Board”(GA-238-03), which isavailable at www.gypsum.orgunder the “Download FreeGypsum AssociationPublications” section.

DECORATIONFor best painting results, all

surfaces, including jointcompound, should be clean,dust-free and not glossy. Toimprove fastener and jointconcealment, a coat of aquality drywall primer isrecommended to equalizethe porosities between thepaper and joint compound.

The selection of a paint to givethe specified or desiredfinished characteristics is theresponsibility of the architector contractor.

XP Gypsum Board that is tohave a wallcovering appliedto it should be prepared andprimed as described forpainting.

Page 15: Ngc Gyp Wall Board

71NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGC

DESCRIPTION

TECHNICAL DATA

Gold Bond® BRAND Exterior Soffit Board

Gold Bond® BRAND ExteriorSoffit Board is designed toprovide, in a fire-resistivegypsum board, the extraresistance to moisture andsagging required to meetoutdoor conditions. Thespecially treated gypsumcore is covered on bothsides with water-repellentpaper formed to the Sta-Smooth edge. Boards are1/2" (regular) and 5/8" (Fire-Shield) x 4' x 8' through 12'lengths.

1. WEIGHTS

1/2" Regular - 1.8 lbs/SF5/8" Type X - 2.2 lbs/SF

2. GENERALUse longest practical board

lengths to minimize thenumber of butt joints.Position end joints atsupports, allowing 1/16" to1/8" between butted ends.When board is appliedwith long edges parallel toframing, framing spacing is16" o.c. max. When boardis applied with long edgesperpendicular to framing,framing spacing may be up to 24" o.c. max. Drivefasteners to provideuniform dimples not over1/32" deep.

3. WOOD FRAMING AND FURRING

Apply Soffit Board with thelong edges at right angles toframing. Use Type “W” 1 1/4" Drywall Screwsspaced 12" o.c. max.Electric screw gun shouldbe equipped withadjustable depth controland a #2 Phillips bit. 1 1/2"galvanized box nails or 1 1/2" aluminum nailsspaced 7" o.c. max., maybe used if desired.

Wood furring 1" x 4" nom. may be used for screwapplication of board wheresupport member spacingdoes not exceed 24" o.c.Furring 2" x 2" nom. mustbe used for nail applicationof board or when supportmember spacing exceeds24" o.c. but is not greaterthan 48" o.c.

Typical uses for shelteredexterior ceiling and soffitareas are covered parkingareas, walkways andmarquees in commercialconstruction and, inresidential construction,carports, breezeways andopen porches.

4. METAL FRAMING AND FURRING

A suspended framework forsupport of the ceiling boardis composed of 1 1/2" cold-rolled steel channels formain runners and either theFurring Channel or theSteel Stud for cross-furring.

Space main runners asfollows: 4' o.c. max. ifFurring Channels are to beused, 6' o.c. max. for 2 1/2"Steel Studs, and 8' o.c. maxfor 3 5/8" Steel Studs. Mainrunners are suspended with8 gauge (min.) galvanizedwire spaced 4' o.c. max.

Secure Furring Channels tomain runners with 1 1/2"Furring Channel Clips,alternating sides at eachintersection, or saddle tiewith double strands of 16gauge galvanized tie wire.

Secure Steel Stud furring tomain runners with doublestrand 16 gauge tie wire16" o.c. max. For addedrigidity, nest an 8" length of track at each tie wirelocation.

Main runners and furring musthave a minimum clearancebetween their ends and anyabutting structural element.A main runner must belocated within 6" of parallelwalls. The ends of theserunners must be supportedby hangers not more than6" from the ends. Theclosest edge of the furringmember must be no morethan 2" from the parallelwall. At any openings forvents, light fixtures, etc.,that interrupt runners orfurring, reinforcement mustbe provided to maintain

support equal to that of theinterrupted members.

Apply Soffit Board with 1"Type “S” Screws, 12" o.c.max.

5. CONTROL JOINTSTo compensate for the effect

of structural movement onlarge ceiling areas, controljoints in the Ceiling/SoffitBoard are recommended.These should be E-Z StripExpansion Joints.

Install E-Z Strip with 1/2" min.staples 6" o.c. Useadditional staples ifnecessary for snug contactwith board. Install joints nomore than 30' apart and, ifpossible, to coincide withexpansion joints in the roofabove. Control joints maybe installed to intersectlight fixture or otheropenings where stresses areusually concentrated.Wings of “L”, “U”, and “I”shaped areas should alwaysbe separated.

6. INTERSECTION WITH OTHER BUILDING ELEMENTS

Allow a minimum 1/4" spacebetween ceiling board andany intersecting structure.Do not caulk this space.Install suitable trimmoulding to conceal thegap or use J Casing Beadand flexible sealant .

7. BOARD EDGE PROTECTION

Install fascia so that its dripline is at least 1/4" belowthe Ceiling Soffit Boardmolding.

8. VENTILATIONProvide at least 1 sq. ft. of

venting to exterior for each150 sq. ft. of Ceiling/SoffitBoard. Vent each enclosedbay. If the space above theceiling board is not open toareas above or belowhabitable rooms, provideventilating area of not lessthan 1/300 of the ceilingarea. Otherwise, vent inaccordance with HUDMinimum PropertyStandard No. 4900.1 or inaccordance with localcodes.

9. JOINT TREATMENTProForm BRAND Sta-Smooth

Joint Compound is requiredfor filling, taping andfinishing. Since Sta-Smoothis a setting material, cut anyhigh points while still wetand wet sand as necessary.

10. PAINTINGThe surface of the Soffit Board

should be painted with twocoats of exterior paint assoon as joint compound isdry, about one week afterjoints are completed.

Page 16: Ngc Gyp Wall Board

72 NATIONAL GYPSUM BOARD PRODUCTS

SPECIFICATIONS

THE FOLLOWING PARAGRAPHS ARE FOR INSERTION INTO SECTIONSOF GENERIC SPECIFICATIONS OR GENERIC/PROPRIETARYSPECIFICATIONS COVERING GYPSUM BOARD PRODUCTS. THENATIONAL GYPSUM PRODUCT NAME FOLLOWS THE GENERICDESCRIPTION IN PARENTHESES.PART 2 PRODUCTS2.01 MATERIALS

A. Exterior Gypsum Soffit Board: A gypsum core soffitboard with additives to enhance the sag resistanceof the core; surfaced with water repellent paper onfront, back, and long edges; and complying withASTM C 1396 (Gold Bond BRAND Exterior SoffitBoard).1. Thickness: 1/2"2. Width: 4'3. Length: 8' through 12'4. Edges: Beveled Tapered (Sta-Smooth Edge)

B. Fire-Resistant Exterior Gypsum Soffit Board: Agypsum core soffit board with additives to enhancethe fire resistance of the core; surfaced with waterrepellent paper on front, back, and long edges; andcomplying with ASTM C 1396, type X (Gold BondBRAND Fire-Shield Exterior Soffit Board).1. Thickness: 5/8"2. Width: 4'3. Length: 8' through 12'4. Edges: Beveled Tapered (Sta-Smooth Edge)

PART 3 EXECUTION3.01 INSTALLATION

A. General: In accordance with the manufacturer’s recommendations, National Gypsum Company “Gypsum Construction Guide.”

1 1/2" C.R. CHANNELHANGERS 48" O.C. MAX.

CEILING/SOFFIT BOARDFURRINGCHANNEL

FURRINGCHANNEL CLIP

RECOMMENDATIONS

INSTALLATION

DETAILS

VENTILATION

VENTILATOR"A"

TO ROOF VENT

VIEW "A"

1/4"

1/4"

EXTERIOR SOFFIT BOARD VENTILATION09250A

Scale: 1 1/2" = 1'-0"

CONTROL JOINT09250B

Scale: 1 1/2" = 1'-0"

FLEXIBLE SEALANT

J CASING BEAD

Installation of Gold Bond Exterior Soffit Board should be inaccordance with page 70 of the National Gypsum Company“Gypsum Construction Guide.”

A qualified structural engineer should evaluate design, includinguplift bracing.

See page 63, Environmental Conditions and Limitations.

Page 17: Ngc Gyp Wall Board

73NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGC

DESCRIPTION

Gold Bond® BRAND 1" Fire-Shield® Shaftliner

TECHNICAL DATA

Gold Bond® BRAND 1" Fire-Shield Shaftliner panelsconsist of a fire-resistanttype X gypsum coreencased in a heavymoisture-resistant green,100% recycled paper onthe face and back sides.The face paper is foldedaround the long edges toreinforce and protect thecore, and the ends aresquare-cut and finishedsmooth. Long edges ofpanels are beveled for easeof installation.

1" Shaftliner panels aredesigned to be used toconstruct lightweight firebarriers for cavity shaftsand area separation wallsin multifamily housing. Thepanels are key componentsin the Cavity ShaftwallSystems and the I-Studand H-Stud AreaSeparation Wall Systems.

SURFACE BURNINGCHARACTERISTICS

ASTM E84Flame Spread: 15Smoke Developed: 0

WEIGHTS1" Shaftliner - 3.75 lbs/SF

FIRE RESISTANCE RATINGSFire resistance ratings repre-

sent the results of tests onassemblies made up ofmaterials authorized byNational Gypsum in specificconfigurations. When selecting construction designs to meet certain fire requirements, caution must be used to ensure that each component of the assembly is the one specified in the test.

Further, precaution should be taken that assembly procedures are in accor-dance with those of the tested assembly. (For copies of specific tests, call 1-800-NATIONAL.)

THE FOLLOWING PARAGRAPHS AREFOR INSERTION INTO SECTIONSOF GENERIC SPECIFICATIONS ORGENERIC/PROPRIETARYSPECIFICATIONS COVERINGGYPSUM BOARD PRODUCTS.THE NATIONAL GYPSUMPRODUCT NAME FOLLOWS THEGENERIC DESCRIPTION INPARENTHESES.

PART 2 PRODUCTS2.01 MATERIALSA. Fire-Resistant Gypsum

Shaftliner Board: A gypsum core shaftwall board with additives toenhance fire resistance ofthe core and surfaced withwater resistant paper onfront, back and long edges; and complying withASTM C 1396, type X (Gold Bond BRAND Fire-Shield Shaftliner).1. Thickness: 1"2. Width: 2'3. Length: 7' through 14'4. Edges: Beveled

SPECIFICATIONS

PART 3 EXECUTION3.01 INSTALLATION

A. General: In accordancewith the manufacturer’srecommendations,National Gypsum Company “GypsumConstruction Guide.”

RECOMMENDATIONS

Installation of 1" Fire-ShieldShaftliner should beconsistent with methodsdescribed in specificapplication details for CavityShaftwall Systems or H-StudArea Separation WallSystems or other fire-rateddesigns shown in NationalGypsum Company “GypsumConstruction Guide.”

Exposure to excessive orcontinuous moisture or standing water and extreme temperatures should be avoided.

To prevent weakening due to calcining, 1" Fire-Shield Shaftliner panels, like any gypsum board, should not be exposed to temperatures over 125˚F (52˚C) for extended periods of time.

Not to be used in an unlined air supply duct.

Always store Shaftliner GypsumPanels flat on a level surfaceand support with properlyplaced risers. Care should betaken to avoid impact,unwarranted flexing andsubsequent damage to boardedges, ends and corners.

Page 18: Ngc Gyp Wall Board

74 NATIONAL GYPSUM BOARD PRODUCTS

DESCRIPTION

Gold Bond® BRAND 1" Fire-Shield® Shaftliner XP®

TECHNICAL DATA

Shaftliner XP™ Gypsum Panelsconsist of a mold and fire-resistant type X gypsumcore encased in a heavymoisture/mold/mildew-resistant, 100% recycledpurple paper on the faceand back sides. ShaftlinerXP was designed toprovide extra protectionagainst mold and mildew.The face paper is foldedaround the long edges toreinforce and protect thecore, and the ends aresquare-cut and finishedsmooth. Long edges ofpanels are beveled for ease of installation.

1" Shaftliner XP Panels aredesigned to be used toconstruct lightweight firebarriers for cavity shaftwalls and area separationwalls in multifamilyhousing. The panels arekey components in CavityShaftwall Systems and H-Stud Area SeparationWall Systems.

SURFACE BURNINGCHARACTERISTICS

ASTM E84Flame Spread: 15Smoke Developed: 0

WEIGHT1" XP - 3.75 lbs/SF

FIRE RESISTANCE RATINGSFire resistance ratings repre-

sent the results of tests onassemblies made up ofmaterials authorized byNational Gypsum in specific configurations. When selecting contruc-tion designs to meet certainfire requirements, caution must be used to ensure thateach component of theassembly is the one specified in the test. Further, precaution should be taken that assembly procedures are in accordance with those of the tested assembly.(For copies of specific tests,call 1-800-NATIONAL)

MOLD AND MILDEWRESISTANCEShaftliner XP was designed to

provide extra protection against mold and mildew.

When tested by anindependent lab per ASTMD3273 (Standard TestMethod for Resistance toGrowth of Mold on theSurface of Interior Coatingsin an EnvironmentalChamber), Shaftliner XPachieved a score of 10, thebest possible score for thistest.

The use of Shaftliner XP inactual installations may notproduce the same results aswere achieved incontrolled, laboratoryconditions. No material canbe considered “mold proof,”nor is it certain that anymaterial will resist moldindefinitely. When used inconjunction with gooddesign, handling andconstruction practices,Shaftliner XP can provideincreased mold resistanceversus standard shaftlinerproducts. As with anybuilding material, avoidingwater exposure duringhandling, storage andinstallation, and afterinstallation is complete, isthe best way to avoid theformation of mold ormildew.

RECOMMENDATIONS

Installation of 1" Shaftliner XPGypsum Panels should beconsistent with methodsdescribed in specificapplication details forCavity Shaftwall Systems, orH-Stud Area Separation WallSystems, or other fire-rateddesigns shown in NationalGypsum Company “GypsumConstruction Guide.”Exposure to excessive or continuous moisture orstanding water and extreme temperatures shouldbe avoided.To prevent weakening dueto calcining, 1" Fire-ShieldShaftliner panels, like anygypsum board, should notbe exposed to temperaturesover 125˚F (52˚C) forextended periods of time.Not to be used in an unlinedair supply duct.Always store Shaftliner XPGypsum Panels flat on alevel surface, and supportwith properly placed risers. to Growth of Mold on theSurface of Interior Coatings.

THE FOLLOWING PARAGRAPHS AREFOR INSERTION INTO SECTIONSOF GENERIC SPECIFICATIONS ORGENERIC/PROPRIETARYSPECIFICATIONS COVERINGGYPSUM BOARD PRODUCTS.THE NATIONAL GYPSUMPRODUCT NAME FOLLOWS THEGENERIC DESCRIPTION INPARENTHESES.

PART 2 PRODUCTS2.01 MATERIALSA. Fire and Mold-Resistant

Gypsum Shaftliner Board:A gypsum core shaftwallboard with additives toenhance fire resistance ofthe core and surfaced witha moisture/mold/mildewresistant paper on front,back and long edges; andcomplying with ASTMC1396, Type X (GoldBond BRAND Fire-ShieldShaftliner XP).1. Thickness: 1"2. Width: 2'3. Length: 7' through 14'4. Edges: Beveled5. Mold and Mildew

Resistance: Panel scoreof 10 when tested in accordance withASTM D3273.

SPECIFICATIONS

PART 3 EXECUTION3.01 INSTALLATION

A. General: In accordancewith the manufacturer’srecommendations,National GypsumCompany “GypsumConstruction Guide.”

Care should be taken toavoid impact, unwarrantedflexing and subsequentdamage to board edges,ends and corners.Shaftliner XP may besubstituted for NationalGypsum’s Gold BoldBRAND Fire-Shield Shaftlinerin Cavity Shaftwall, AreaSeparation Wall Systemsand solid laminatedpartitions.

Page 19: Ngc Gyp Wall Board

75NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGC

DESCRIPTION

Gold Bond® BRAND High Flex® Gypsum Board

TECHNICAL DATA

Gold Bond BRAND High FlexGypsum Board consists ofa fire-resistive gypsum coreencased in heavy natural-finish paper on the faceside and strong liner paperon the back side. The facepaper is folded around thelong edges to reinforceand protect the core andthe ends are square-cutand finished smooth. Longedges of boards are slightlytapered, allowing joints tobe reinforced andconcealed with ProFormJoint Tape and JointTreatment Compounds.

1/4" High Flex Gypsum Boardis specifically designed forradius construction such ascurved walls, archwaysand stairways. It can beused for both concave andconvex surfaces. 1/4" HighFlex is typically applied indouble layers.

1/4" High Flex Gypsum Boardis a lightweight, cost-efficient material thatreadily accepts a widerange of decorativefinishes.

1/4" High Flex Gypsum Boardis easily cut for quickinstallation, permittingpainting or otherdecoration and theinstallation of metal orwood trim almostimmediately.

The gypsum core is non-combustible.

With joints reinforced byProForm BRAND JointCompounds, Gold BondGypsum Board forms wallsand ceilings exceptionallyresistant to cracks causedby structural and thermalchanges.

Expansion and contractionunder normal atmosphericchanges is negligible.

RECOMMENDATIONS

Installation of Gold Bond BRANDgypsum board should beconsistent with methodsdescribed in GA216

“RecommendedSpecifications for theApplication of GypsumBoard,” ASTM C 840,“Standard Specifications forApplication and Finishing ofGypsum Board,” andGA214, “RecommendedLevels of Gypsum BoardFinish.”

Exposure to extremetemperatures should beavoided. 1/4" High FlexGypsum Board is notrecommended where it willbe exposed to temperaturesexceeding 125˚F.

Installing 1/4" High FlexGypsum Board over aninsulating blanket, installedcontinuously across the faceof the framing members, isnot recommended. Blanketsshould be recessed andflanges attached to the sidesof the studs or joists.

For best painting results, allsurfaces, including jointcompound, should beclean, dust-free and notglossy. To improve fastenerand joint concealment, acoat of a quality latexprimer is recommended toequalize the absorptionbetween surface paper andjoint compound.

1/4" High Flex Gypsum Boardshould be applied first toceiling at right angles toframing members, then towalls. Boards of maximumpractical length should beused so that an absoluteminimum number of endjoints occur. Board edgesshould be brought intocontact with each other butshould not be forced intoplace.

1/4" High Flex Gypsum Boardis significantly more flexiblein the vertical direction(long edges parallel to theframing) than in thehorizontal direction. (SeeTable 1.)

Gypsum board joints atopenings should be locatedso that no end joint willalign with edges of openingsunless control joints will beinstalled at these points. Endjoints should be staggered,and joints on opposite sidesof a partition should notoccur on the same stud.

1/4" High Flex Gypsum Boardis typically installed indouble layer construction.To prevent flat spots,framing members should be

MINIMUM BENDING RADII FOR 1/4" HIGH FLEX GYPSUM BOARD

Lengthwise Widthwise

Bend Max. Stud Bend Max. StudApplication Radii Spacing Radii Spacing

Inside (Concave) Dry 32" 9" o.c. 20" 9" o.c.

Outside (Convex) Dry 30" 9" o.c. 15" 8" o.c.

Inside (Concave) Wet 20" 9" o.c. 10" 6" o.c.

Outside (Convex) Wet 14" 6" o.c. 7" 5" o.c.

Lengthwise denotes long edges perpendicular to the framingmembers. Widthwise denotes long edges parallel to the framingmembers. The values listed in Table 1 were achieved at 65° F and45% relative humidity. Lower temperatures and lower humiditywill decrease the flexibility.

Wetting the board is only required on extremely tight radii, or whentemperature and humidity conditions are lower than 65° F and45% relative humidity. When wetting the board, apply 10-15ounces of clean water per side with a paint roller or sprayer.Allow to soak 10-15 minutes before bending.

Table 1

spaced closer together thanrequired for typical flat walland ceiling surfaces (seeTable 1). 1/4" High FlexGypsum Board should beheld in firm contact withthe framing member whilefasteners are being driven.

For concave surfaces, a stopshall be applied to one endof the curve to restrain oneend or edge of the boardduring installation. Pressureshall be applied to theunrestrained end or edge ofthe gypsum board forcingthe field of the gypsumboard into firm contactwith the framing. Gypsumboard shall be fastened byworking from the“stopped” end or edge. Thegypsum board shall be heldtightly against the framingwhile fasteners are beingdriven.

For convex surfaces, one endof the gypsum board shallbe attached to the framingwith nails or screws. Thegypsum board shall beprogressively pushed intocontact with the framingmembers, working fromthe fixed end to the freeend. The gypsum boardshall be held tightly againsteach framing memberwhile fasteners are beingdriven.

Fasteners should be set withthe heads slightly belowthe surface of the gypsumboard in a dimple formedby the hammer or powerscrewdriver. Care shouldbe taken to avoid breakingthe face paper of thegypsum board. Improperlydriven nails or screwsshould be removed.

SURFACE BURNINGCHARACTERISTICS

ASTM E 84Flame spread: 15Smoke developed: 0

WEIGHT1/4" High Flex - .95 lbs/SF

Page 20: Ngc Gyp Wall Board

76 NATIONAL GYPSUM BOARD PRODUCTS

SPECIFICATIONS

THE FOLLOWING PARAGRAPHS AREFOR INSERTION INTO SECTIONSOF GENERIC SPECIFICATIONS ORGENERIC/PROPRIETARYSPECIFICATIONS COVERINGGYPSUM BOARD PRODUCTS.THE NATIONAL GYPSUMPRODUCT NAME FOLLOWS THEGENERIC DESCRIPTION INPARENTHESES.

PART 2 PRODUCTS2.01 MATERIALS

A. Flexible Gypsum Board:A gypsum core wallboard with additives toenhance flexibilitysurfaced with paper onfront, back and longedges and complyingwith ASTM C 1396.(High Flex BRANDGypsum Board).

1. Thickness: 1/4" 2. Width: 4' 3. Length: 8' through 12' 4. Edges: Slightly tapered

PART 3 EXECUTION3.01 INSTALLATION

A. General: In accordancewith the manufacturer’s recommendations,National GypsumCompany “Gypsum Construction Guide.”

Page 21: Ngc Gyp Wall Board

77NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGC

DESCRIPTION

Gold Bond® BRAND High Strength Ceiling Board

TECHNICAL DATA

Gold Bond BRAND HighStrength Ceiling Board is aspecialty gypsum board withincreased uniformity andintegrity of its gypsum core,making its sag resistanceequivalent to 5/8" type Xgypsum board.

1/2" High Strength CeilingBoard is specificallydesigned for ceilings whereframing members are spacedup to 24" o.c. and a water-based texture will be used.

1/2" High Strength CeilingBoard is availablenationwide as a stockeditem at all National Gypsumplants.

Excellent working character-istics, improved score andsnap properties reduce theneed for rasping.

Excellent sag resistance.Witnessed test results showoverall sag on testedassembly to be equivalent to5/8" type X gypsum board.Test report available uponrequest.

Eliminates need for two boardsizes on the job. Scrap fromceiling is reduced since thismaterial also can be used onthe walls.

RECOMMENDATIONS

SPECIFICATIONS

THE FOLLOWING PARAGRAPHS AREFOR INSERTION INTO SECTIONSOF GENERIC SPECIFICATIONS ORGENERIC/PROPRIETARYSPECIFICATIONS COVERINGGYPSUM BOARD PRODUCTS.THE NATIONAL GYPSUMPRODUCT NAME FOLLOWS THEGENERIC DESCRIPTION INPARENTHESES.

PART 2 PRODUCTS2.01 MATERIALS

A. Gypsum Ceiling Board:A gypsum core ceilingboard with additives toenhance the sagresistance of the coreand surfaced with paperon front, back, and longedges, complying with ASTM C 1396 andFederal specification

In independent tests, HighStrength Ceiling Boardexhibited an average sag ofonly .033 (approx. 1/32")on joists spaced 24" oncenter with a spray textureapplied. This test wasconducted over one monthat temperatures between66˚-79˚F (19˚C-26˚C) andrelative humidities between30%-60%. (Reference: PSIreport #722600-R71 March25, 1991)

Under the strict ASTM C-473Physical Testing forHumidified Deflection,Gold Bond BRAND 1/2"High Strength CeilingBoard exhibited sag-resistant properties equal to5/8" type X gypsum board.

SURFACE BURNINGCHARACTERISTICS

ASTM E 84Flame spread index: 15Smoke developed: 0

WEIGHT1/2" Hi Strength - 1.8 lbs/SF

Installation of Gold Bond BRANDGypsum Board should beconsistent with methodsdescribed in, GA216,“RecommendedSpecifications for theApplication of GypsumBoard,” ASTM C 840,“Standard Specification forApplication and Finishing ofGypsum Board.”

Not recommended in areas ofcontinuous high humiditysuch as saunas, steamrooms, gang shower rooms,and indoor pool enclosures.Prime with sealing latexprimer and allow to drythoroughly. Apply insulationand polyethylene vaporbarrier (if used) beforeinstalling ceiling board.Insulation not to exceed 2.2lbs./square foot (10.7 kg/m2).Adequate ventilationrequired.

1/2" High Strength CeilingBoard must be stored off theground and under cover.Sufficient risers must beused to ensure support forthe entire length of thegypsum board to preventsagging.

Not to be exposed totemperatures exceeding125˚F (52˚C) for extendedperiods of time.

Installing gypsum board overan insulating blanket,installed continuously acrossthe face of the framingmembers, is notrecommended. Blanketsshould be recessed andflanges attached to the sidesof the studs or joists.

DECORATIONFor best painting results, all

surfaces, including jointcompound, should be clean,dust-free and not glossy. Toimprove fastener and jointconcealment, a coat of aquality primer isrecommended to equalizethe porosities betweensurface paper and jointcompound. Drywall primeris a product speciallyformulated for this purpose.

The selection of a paint to givethe specified or desiredfinished characteristics is theresponsibility of thearchitect or contractor.

Gypsum board that is to have awallcovering applied to itshould be prepared andprimed as described forpainting.

Gypsum Association GA-214,Recommended Specificationfor Levels of Gypsum BoardFinish, should be referred toin order to determine thelevel of finishing needed toensure a surface properlyprepared to accept thedesired decoration.

SS-L-30D type III, Grade R, Class 1. (Gold

Bond BRAND High StrengthCeiling Board).1. Thickness: 1/2" 2. Width: 4' 3. Length: 6' through 16' 4. Edge: Tapered

PART 3 EXECUTION3.01 INSTALLATION

A. General: In accordancewith the manufacturer’s recommendations,National GypsumCompany “Gypsum Construction Guide.”

Page 22: Ngc Gyp Wall Board

78 NATIONAL GYPSUM BOARD PRODUCTS

0.230

0.132

0.000

0.050

0.100

0.150

0.200

0.250

0.300

0.350

0.400

0

50

100

150

200

250

300

120

210

Walls and ceilings in school corridors and cafeterias are idealapplications for Gold Bond® BRAND Hi-Abuse XP® Gypsum Board.

Gold Bond® BRAND Hi-Abuse XP® Gypsum Board panels consist of a mold and fire resistant type x gypsum core encased in heavy mooth abrasion resistant, moisture, mold/mildew-resistant, 100% recycled purple paper on the face side and heavy mold/mildew-resistant liner paper on the back side. Hi-Abuse XP Gypsum Board is designed to provide extra protection against mold and mildew compared to standard gypsum board products. The panels feature a specifically formulated core to provide greater resistance to surface indentation and impact than fiber-reinforced gypsum panels. Long edges of the panels are tapered. Tapered edges allow joints to be treated in the normal manner. For optimum mold and mildew resistance, National Gypsum recommends ProForm BRAND XP Ready Mix, or Sta-Smooth/Sta-Smooth Litesetting compounds.

TECHNICAL DATA

Surface Abrasion TestASTM – D 4977 (Modified)

5/8" 5/8" Gypsum BoardHi-Abuse XP Type X

Mean Depth Abrasion 0.009 in. 0.576 in.

Performance Classification Level 3 Does Not Qualify

Procedure Summary – A sample is laid flat and subjected to 50 abrasion cycles of a wire brushwith additional 25 lbs. weight. The depth of abrasion in three consecutive samples is measured andreported as a mean depth of abrasion in inches. This test measures the ability of a panel to withstandsurface scuffs and abrasions.

Surface Abrasion TestASTM-D 4977 (Modified)

5/8" Hi-Abuse XP

Surface Indentation Resistance Modified ASTM – D 5420 (Gardner Impact)

5/8" 5/8" Gypsum Board Hi-Abuse XP Type X

Mean Depth of indentation 0.132 in. 0.230 in.Performance Classification Level 1 Does Not Qualify

Procedure Summary – A sample is laid flat and impacted by a 5/8" hemispherical rod raised toheight that provides 72 in.-lbs. of impact energy. The depth of the indentation is measured from three board samples and reported as a mean depth of indentation in inches. This test measures theability for a panel to resist dents.

Dept

h of

Inde

ntat

ion

(in.)

5/8" Hi-Abuse XP

Surface Indentation TestASTM-D 5420

Single Drop Soft Body Impact Test Modified ASTM – E 695 (Modified)

5/8" 5/8" Gypsum Board Hi-Abuse XP Type X

Ft.-Lbs. required to penetrate 210 120

Performance Classification Level 2 Level 1

Procedure Summary – This test is conducted with a leather bag loaded with steel pellets to aweight of 60 lbs. The bag is suspended by a rope and dropped at an angular distance untilspecimen is impacted.

Single Drop Soft Body TestASTM -E 695 (Modified)

Impa

ct F

orce

in ft

.lbs.

5/8" Hi-Abuse XP

DESCRIPTION

5/8" Gypsum Board, Type X

Dept

h of

Abr

astio

n (in

.)

5/8" Gypsum Board, Type X5/8" Gypsum Board, Type X

Gold Bond® BRAND Hi-Abuse XP® Gypsum Board

Page 23: Ngc Gyp Wall Board

79NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGC

Installation of Hi-Abuse XPGypsum Board should be consistent with methods described in the standards references noted. For bestperformance, use verticalapplication.

GridMarX®

Hi-Abuse® BRAND XP GypsumBoard comes standard with GridMarX® guide marksprinted on the paper surface.These guide marks align withstandard building dimen-sions and help to quicklyidentify fastener lines for studand joist framing. Using GridMarX, accurate cuts canbe made without having to draw lines. The use of GridMarX also provides quick identification and uniform nail/screw patterns.

GridMarX guide marks run themachine direction of the board at five points in 4"increments. Marks run alongthe edge in both tapers andand at 16", 24" and 32" in the field of the board. The marks cover easily with nobleed-through using stand-ard products.

Vertical Application - In a vertical application, GridMarX serves as a guide mark to help identify the exact location of framingmembers behind the gypsumboard, eliminating the needfor field-applied vertical lines.

Horizontal Application - In a horizontal application,GridMarX serves as a reference mark to helpidentify the location of framing members behind the gypsum board. (If framingmember is located 2" to the right of the GridMarX at thetop edge of the board, it willbe located 2" to the rightdown the face of the board.)

Provides greater resistance to surface abuse, indentationand impact than fiber-rein-forced gypsum panels.

Hi-Abuse XP smooth facepaper is highly resistant toscuffing when sandinggypsum board joints and fasteners providing a superior surface for deco-ration.

Hi-Abuse XP Gypsum Board iseasily scored and snappedfor quick installation. Open-ings and outlet boxes arecut out in same manner asregular gypsum board.

RECOMMENDATIONSSURFACE BURNINGCHARACTERISTICS

ASTM E 84Flame spread (Face): 15Smoke developed: 0

WEIGHT

1/2" Hi-Abuse XP - 2.4 lbs/SF5/8" Type X Hi-Abuse - 2.8 lbs/SF

FIRE RESISTANCE RATINGSFire resistance ratings represent

the results of tests on assem-blies made up of specificmaterials in a specific con-figuration. When selectingconstruction designs to meetcertain fire resistance re-quirements, caution must beused to ensure that each component of the assemblyis the one specified in the test. Further, precautionshould be taken that assem-bly procedures are in accor-dance with those of thetested assembly. (For copiesof specific tests, call1-800-NATIONAL.)

MOLD AND MILDEWRESISTANCEHi-Abuse® BRAND XP Gypsum

Board has been designed toprovide extra protectionagainst mold and mildewcompared to standardgypsum board products.When tested by anindependent lab per ASTMD3273 (“Standard TestMethod for Resistance toGrowth of Mold On theSurface of Interior Coatings inan Environmental Chamber”),Hi-Abuse XP Gypsum Boardachieved a score of 10, thebest possible score for thistest.

The use of Hi-Abuse XPGypsum Board in actualinstallations may not produce the same results as were achieved in controlled,laboratory conditions. Nomaterial can be considered“mold proof,” nor is itcertain any material willresist mold or mildewindefinitely. When used in conjunction with gooddesign, handling andconstruction practices, Hi-Abuse XP Gypsum Boardcan provide increased moldresistance versus standardgypsum board products. Aswith any building material,avoiding water exposureduring handling, storage andinstallation, and afterinstallation is complete, isthe best way to avoid theformation of mold ormildew.

Minimum bending radii for5/8" Hi-Abuse XP Gypsum Board is 20'-0" applied lengthwise perpendicular to framing spaced not greater than 12" on center.

Lightweight, cost-efficientmaterial that readily accepts a wide range of decorativefinishes.

The gypsum core will notsupport combustion ortransmit temperatures great-ly in excess of 212˚F (100˚C)until completely calcined, aslow process.

Expansion and contraction under normal atmosphericchanges are negligible.

Hi-Abuse XP 5/8" Fire-Shieldpanels may be used where Type X gypsum panels arespecified in fire-rated walland floor-ceiling assemblies(i.e. UL, U300, U400, V400and L500 series.)

Exposure to excessive or continuous moisture andextreme temperatures shouldbe avoided. Hi-Abuse XPGypsum Board is not recom-mended where it will beexposed to temperaturesexceeding 125˚F (52˚C) forextended periods of time.

Hi-Abuse XP Gypsum Board shall not be used where there will be direct exposureto water or continuous highhumidity conditions, such asfound in tub and showerenclosures, saunas, steamrooms and gang showers. Ifthe area is to be exposed towater or continuous highhumidity, National Gypsum’s PermaBase®

BRAND Cement Board shouldbe used.

Hi-Abuse XP Gypsum Board must be stored off the ground and under cover. Sufficient risers mustbe used to ensure supportfor the entire length of thegypsum board to preventsagging.

Page 24: Ngc Gyp Wall Board

80 NATIONAL GYPSUM BOARD PRODUCTS

DECORATIONFor best painting results, all sur-

faces, including joint com-pound, should be clean,dust-free and not glossy. Toimprove fastener and jointconcealment, a coat of a quality drywall primer is re-commended to equalize theporosities between surfaceand joint compound.

The selection of a paint to givethe specified or desired finished characteristics is theresponsibility of the architector contractor.

Hi-Abuse XP Gypsum Board that is to have a wall covering applied to it shouldbe prepared and primed as described for painting.

Gypsum Association GA-214,“Recommended Specifica-tions for Levels of GypsumBoard Finish,” should be re-ferred to in order to deter-mine the level of finishingneeded to ensure a surfaceproperly prepared to acceptthe desired decoration.

PART 2 PRODUCTS2.01 MATERIALSA.Fire, Abuse and Mold

Resistant Gypsum Board: A gypsum core wall panel with additives to enhance fire resistance, surface indentation resistance and impact resistance of the core and surfaced with abra-sion, moisture/mold/mildewresistant paper on front, back and long edges; and complying with ASTM C 1396 Type X (Hi-Abuse BRAND XP Fire-Shield Gypsum Board).1. Thickness: 5/8"2. Width: 4'3. Length: 8' through 12'4. Edges: Tapered5. Surface Abrasion Resis-

tance: Not greater than0.009 depth when testedat 50 cycles in accord-ance with ASTM D 4977,modified.

6. Indentation Resistance:Not greater than 0.132"depth when tested at animpact load of 72 in.-lbs.

SPECIFICATIONS

In accordance with ASTMD 5420.

7. Impact/Penetration Resist-ance: Not less than 210ft.-lbs. required to penetrate when tested in accordance with ASTM E 695, modified.

8. Mold/Mildew Resistance:Panel score of 10 when tested in accordance withASTM D 3273.

PART 3 EXECUTION3.01 INSTALLATIONA. General: In accordance

with the manufacturer’srecommendations, National Gypsum Company“Gypsum Construction Guide.”

Hi-Abuse XP Gypsum Board must be kept dry to mini-mize the potential for moldgrowth. Adequate care should be taken while trans-porting, storing, applying and maintaining gypsumboard. For additionalinformation, refer to theGypsum Association pub-lication, “Guidelines forthe Prevention of MoldGrowth on Gypsum Board”(GA-238-03), whichis available at www.gypsum.org under the“Download Free GypsumAssociation Publications”section.

THE FOLLOWING PARAGRAPHS AREFOR INSERTIONS INTO SECTIONSOF GENERIC SPECIFICATIONS ORGENERIC/PROPRIETARY SPECIFI-CATIONS COVERING GYPSUMBOARD PRODUCTS. THENATIONAL GYPSUM PRODUCTNAME FOLLOWS THE GENERICDESCRIPTION IN PARENTHESES.

Page 25: Ngc Gyp Wall Board

NATIONAL GYPSUM BOARD PRODUCTS 81

09

29

00

09 29 00/NGC

0.230

0.114

0.000

0.050

0.100

0.150

0.200

0.250

0.300

0.350

0.400

120

> 540 *

0

100

200

300

400

500

600

DESCRIPTION

Gold Bond® BRAND Hi-Impact XP® Gypsum Board panels consist of a mold, moisture and fire resistant type X gypsum core encased in heavy, smooth, abrasion-resistant, mold/mildew-resistant, 100% recycled purple paper on the face side and heavy mold/mildew resistant liner paper on the back side. A fiberglass mesh is embedded in the core, close to the back of the board to provide additional impact/penetration resistance.Hi-Impact XP Gypsum Board features a specially formulated core to provide fire resistance ratings when used in tested systems in addition to providing extra protection against moldand mildew compared to standard gypsum board products. Long edges of panels are tapered. Tapered edges allow joints to be treated in the normal manner. For optimum mold and mildew resistance, National Gypsum recommends ProForm BRAND XP Ready Mix, or Sta-Smooth/Sta-Smooth Litecompounds.

TECHNICAL DATA

Surface Abrasion ASTM – D 4977 (Modified)

5/8" Hi-Impact XP 5/8" Gypsum Boardwith Fiberglass Scrim Type X

Mean Depth Abrasion 0.009 in. 0.576 in.

Performance Classification Level 3 Does Not QualifyProcedure Summary – A sample is laid flat and subjected to 50 abrasion cycles of a wire brushwith additional 25 lbs. weight. The depth of abrasion in three consecutive samples is measured andreported as a mean depth of abrasion in inches. This test measures the ability of a panel to withstandsurface scuffs and abrasions.

Surface AbrasionASTM – D 4977(Modified)

Dept

h of

Abr

asio

n (in

.)

5/8" Hi-Impact XPwith Fiberglass Scrim

Surface Indentation TestASTM – D 5420 (Gardner Impact)

5/8" Hi-Impact XP 5/8" Gypsum Boardwith Fiberglass Scrim Type X

Mean Depth of indentation 0.114 in. 0.230 in.Performance Classification Level 1 Does Not Qualify

Procedure Summary – A sample is laid flat and impacted by a 5/8" hemispherical rod raised toheight that provides 72 in.-lbs. of impact energy. The depth of the indentation is measured from threeboard samples and reported as a mean depth of indentation in inches. This test measures the abilityfor a panel to resist dents.

Dept

h of

Inde

ntat

ion

(in.)

5/8" Hi-Impact XPwith Fiberglass Scrim

Surface Indentation TestASTM – D 5420

Single Drop Soft Body Impact Test ASTM – E 695 (Modified)

5/8" Hi-Impact 5/8" Gypsum Boardwith Fiberglass Scrim Type X

Ft.-Lbs. required to penetrate >540* 120

Performance Classification Level 3 Level 1

Procedure Summary – This test is conducted with a leather bag loaded with steel pellets to aweight of 120 lbs. The bag is suspended by a rope and dropped at an angular distance until specimenis impacted.* In the test the framing collapsed without failure to the Hi-Impact panels.

Single Drop Soft Body TestASTM-E 695 (Modified)

Impa

ct F

orce

in ft

.-lb

s.

5/8" Hi-Impact XPwith Fiberglass Scrim

5/8" Gypsum Board, Type X

5/8" Gypsum Board, Type X5/8" Gypsum Board, Type X

Prison walls have to be strong. And, with GOLD BOND® BRANDHi-Impact XP® Gypsum Board, strong walls can be installed aseasily as regular gypsum board.

Gold Bond® BRAND Hi-Impact XP® Gypsum Board

Page 26: Ngc Gyp Wall Board

82 NATIONAL GYPSUM BOARD PRODUCTS

Hard Body Impact - ASTM C 1629

5/8" Hi-Impact XP 5/8" Gypsum Boardwith Fiberglass Scrim Type X

Ft.-lbs. to penetrate into cavity >160 35Performance Classification Level 3 Does Not Qualify

Procedure Summary – A 2' x 2' board sample is mounted to a 3-5/8", 20 gauge steel frame andrunners using drywall screws. The sample is impacted with a ram mounted on a pendulum which isfaced with a 2-3/4" steel cylinder dropped from a fixed height. Weights are added to increase theimpacting energy. The maximum impact force that the sample can withstand without penetrationthrough the sample and into the stud cavity is reported in foot-pounds. This test measures the abilityto withstand the impact of a hard object such as a hammer or heel of a boot.

35

>160

0

20

40

60

80

100

120

140

160

180

Impa

ct F

orce

in ft

.-lb

s.

5/8" Hi-Impact XPwith Fiberglass Scrim

Hard Body Impact

Water AbsorptionASTM C 473

5/8" High-Impact XP 5/8" Gypsum Boardwith Fiberglass Scrim Type X

Percentage of Weight Gained 4% 47%

Procedure Summary – Three dry board samples were cut and weighed. Each sample was thensubmerged in a 3-inch water bath for two hours. The samples were removed, wiped and weighedagain. The weight gained is calculated and reported as a percentage. The higher the percentage themore water the panel absorbed.

4%

0

5%

10%

15%

20%

25%

30%

35%

40%

45%

50%

47%

% o

f Wei

ght G

ain

5/8" Hi-Impact XPwith Fiberglass Scrim

Water AbsorptionASTM C 473

Less is Better

at 16", 24" and 32" in the field of the board. The marks cover easily with no bleed-through using standard products.

Vertical Application - In a vertical application, GridMarX serves as a guidemark to help identify theexact location of framingmembers behind the gypsumboard, eliminating the needfor field-applied vertical lines.

Horizontal Application - In a horizontal application, GridMarX serves as a reference mark to helpidentify the location of framing members behind the gypsum board. (If framingmember is located 2" to the right of the GridMarX at thetop edge of the board, it willbe located 2" to the rightdown the face of the board.)

Hi-Impact XP Gypsum Board canbe used as a tile backer boardin dry areas and areas with limited water exposures suchas toilet/sink areas and areasabove tile in tubs and showers

Hi-Impact XP Gypsum Boardshould not be used as a backerboard directly behind tile intub and shower areas.

Hi-Impact XP should not be usedin areas subject to constantand/or excessive moisture andhigh humidity such as gangshowers, saunas, steam roomsand swimming pool enclo-sures. PermaBase BRANDcement board is recommendedfor these areas.

Hi-Impact XP Gypsum Board canbe used on the interior sideof exterior walls in hot, hu-mid climates such as theSouthern Atlantic and GulfCoast areas.

Hi-Impact XP Gypsum Board features a type X core toprovide additional fireresistance when used in tested systems.

Hi-Impact XP Gypsum Board iseasily cut for quick installa-tion, permitting painting orother decoration and theinstallation of most metalor wood trim almost immediately.

Minimum bending radii for 5/8"Hi-Impact XP Gypsum Board is20'-0" applied lengthwise perpendicular to framingspaced not greater than 12"on center.

The gypsum core will notsupport combustion or trans-mit temperatures greatly inexcess of 212˚F (100˚C)until completely calcined,a slow process.

SURFACE BURNINGCHARACTERISTICS

ASTM E 84(Face)Flame spread: 15Smoke developed: 0

WEIGHT5/8" Hi-Impact XP - 2.8 lbs/SF

specified in the test. Furtherprecaution should be taken specified in the test. Further precaution should be taken that assembly procedures are in accordance with those of the tested assembly. (For copies of specific tests, call 1-800-NATIONAL.)

FIRE ENDURANCE1-Hour Rating: Hi-Impact XP

Gypsum Board screw attached vertically to both sides of 20 gauge 3-5/8" studs spaced16" o.c. with 1-1/4"long, type S screws spaced 8"o.c. along edges and 12" o.c. in the field of the board. Gypsum board joints staggered. UL U465

2-Hour Rating: Constructedwith a base layer of Hi-Impact XP Gypsum Boardwith an additional layerof 5/8" Fire-Shield GypsumBoard Type X screw attach-ed vertically to both sides of20 gauge 3-5/8" studs spaced 16" o.c. with jointsstaggered between face andbase layer. Base layer attached with 1-1/4" longtype S screws spaced 8"o.c. along edges and 12"o.c. in the field of the board.Outer layer attached with 2-1/2" long type S screwsspaced 8" o.c. in the fieldand along vertical edges andto the floor and ceiling runners. UL U411

For additional UL Design Listings, please referencethe UL Directory.

Installation of 5/8" Hi-Impact XP Fire-Shield Type X Gypsum Board should be consistent with methods described in Applicable Standards with one exception - for best results,cutting and scoring of Hi-Impact XP should be fromthe back side of the board.

GridMarX®

Hi-Impact XP Gypsum Board comes standard with GridMarX® guide marks printed on the paper surface. These guide marks align with standard building dimensions and help to quickly identify fastener lines for stud and joist framing. Using GridMarX,accurate cuts can be made without having to draw lines. The use of GridMarX also provides quick identification and uniform nail/screw patterns.

GridMarX guide marks run themachine direction of the board at five points in 4"increments. Marks run alongthe edge in both tapers andat 16", 24" and 32" in the field of the board. The marks

laboratory conditions. Nomaterial can be considered “mold proof,” nor is it certainany material will resist moldor mildew indefinitely. Whenused in conjunction withgood design, handling andconstruction practices, Hi-Impact XP Gypsum Boardcan provide increased moldresistance versus standardgypsum board products. Aswith any building material,avoiding water exposureduring handling, storage andinstallation, and afterinstallation is complete, is thebest way to avoid theformation of mold or mildew.

FIRE RESISTANCE RATINGSFire resistance ratings represent

the results of tests on assem-blies made up of specificconfiguration. When selecting constructiondesigns to meet certain fire resistance requirements, caution must be used to ensure that each component of the assembly is the one

RECOMMENDATIONS

MOLD AND MILDEWRESISTANCEHi-Impact® XP Gypsum Board has

been designed to provide extraprotection against mold andmildew compared to standardgypsum board products. Whentested by an independent labper ASTM D3273 (“StandardTest Method for Resistance toGrowth of Mold On theSurface of Interior Coatings inan Environmental Chamber”),Hi-Impact XP Gypsum Boardachieved a score of 10, the bestpossible score for this test.

The use of Hi-Impact XPGypsum Board in actualinstallations may not produce the same results as were achieved in controlled,

5/8" Gypsum Board, Type X

5/8" Gypsum Board, Type X

Page 27: Ngc Gyp Wall Board

NATIONAL GYPSUM BOARD PRODUCTS

09 29 00/NGC

83

09

29

00

Exposure to excessive orcontinuous moisture andextreme temperatures shouldbe avoided.

Listed impact/penetrationratings apply to walls con-structed with Hi-Impact XPGypsum Board applied with long edges parallel to and centered over minimum 20gauge framing membersspaced a maximum of 16"o.c.

Hi-Impact XP Gypsum Boardmust be stored off the ground and under cover.Sufficient risers must beused to ensure support forthe entire length of thegypsum board to preventsagging.

Hi-Impact XP Gypsum Board must be kept dry to mini-mize the potential for moldgrowth. Adequate care should be taken while trans-porting, storing, applying and maintaining gypsumboard. For additionalinformation, refer to theGypsum Association pub-lication, “Guidelines forthe Prevention of MoldGrowth on Gypsum Board” (GA-238-03), whichis available at www.gypsum.org under the“Download Free GypsumAssociation Publications”section.

DECORATIONFor best painting results, all

surfaces, including jointcompound, should be clean,dust-free and not glossy. Toimprove fastener and jointconcealment, a coat of highquality latex primer is recommended to equalizethe absorption between sur-face paper and joint com-pound. Drywall primer is specially formulated for thispurpose.

The selection of a paint to givethe specified or desiredfinished characteristics is theresponsibility of the architector contractor.

Hi-Impact XP Gypsum Board that is to have a wall covering applied to it shouldbe prepared and primed as described for painting.

Gypsum Association GA-214,“Recommended Specifica-tion for Levels of GypsumBoard Finish,” should bereferred to in order to deter-mine the level of finishingneeded to ensure a surfaceproperly prepared to acceptthe desired decoration.

THE FOLLOWING PARAGRAPHS AREFOR INSERTION INTO SECTIONSOF GENERIC SPECIFICATIONS FORGENERIC/PROPRIETARY SPECIFI-CATIONS COVERING GYPSUMBOARD PRODUCTS. THENATIONAL GYPSUM PRODUCTNAME FOLLOWS THE GENERICDESCRIPTION IN PARENTHESES.

PART 2 PRODUCTS2.01 MATERIALSA. Fire, Impact/Penetration and Mold-Resistant GypsumBoard: A gypsum core wallpanel with additives toenhance the fire andresistance, and mold/mildewresistance of the core; surfacedwith abrasion/moisture/mold/mildew resistant paper on thefront, back and long edgeswith a fiberglass meshembedded in the board toenhance impact/penetrationresistance and complying withASTM C 1396, Type X. (Gold Bond BRAND Hi-ImpactXP Fire-Shield Gypsum Board).

1. Thickness: 5/8"2. Width: 4'3. Length: 8' through 12'4. Edges: Tapered

SPECIFICATIONS

5. Surface Abrasion Resis-tance: Not greater than0.009" depth when tested at 50 cycles in accordance with ASTMD 4977, Modified.

6. Indentation Resistance:Not greater than 0.114"depth when tested at an impact load of 72 in.-lbs. in accordance with ASTM D 5420.

7. Impact/PenetrationResistance: Not less than720 ft.-lbs. required to penetrate when tested inaccordance with ASTM E 695, Modified.

8. Mold/Mildew Resistance: Panel scoreof 10 when tested inaccordance with ASTMD 3273.

PART 3 EXECUTION3.01 INSTALLATION

A. General: In accordancewith the manufacturer’srecommendations, National Gypsum Company “Gypsum Construction Guide.”

Page 28: Ngc Gyp Wall Board

84 NATIONAL GYPSUM BOARD PRODUCTS

DESCRIPTION

GOLD BOND® BRAND SoundBreak™ Gypsum Board

Gold Bond® BRANDSoundBreak™ GypsumBoard is an acousticallyenhanced gypsum boardused in the construction ofhigh rated STC wallassemblies. This 5/8" thickgypsum board consists of alayer of viscoelasticdamping polymersandwiched between twopieces of enhanced highdensity mold resistantgypsum board, providingconstrained layer damping.

For speed of installations,GridMarX® guide marks areprinted on the papersurface.

Long edges of the panels aretapered. Tapered edgesallow joints to bereinforced with ProForm®

BRAND Joint Tape andconcealed with ProForm®

BRAND Ready Mix, EasyFinish® BRAND Ready Mix orProForm® BRAND Sta-Smooth® Joint Compounds.For optimum mold andmildew performance,National Gypsumrecommends ProForm®

BRAND XP® Ready Mix.Use of SoundBreak Gypsum

Board results in wallpartitions with high ratedSTC values that are thinnerthan traditionally built highrated STC wall partitions,providing increased usablefloor space.

Superior sound damping, cost-efficient material that iseasily finished anddecorated in the samemanner as regular gypsumboard.

All SoundBreak GypsumBoard designs were testedby an independent third-party acoustical laboratoryusing the full scale ASTME90 test procedure.

SoundBreak Gypsum Board isinstalled like traditionalgypsum board offering amore reliable and lesscomplicated solution thanalternative methodsrequiring clips and/orchannels.

SoundBreak Gypsum Boardcan be cut by scoringdeeply from both sides ofthe board before snapping,or with the use of a handor reciprocating saw.

When tested by anindependent lab per ASTMD3273 (“Standard TestMethod for Resistance toGrowth of Mold on theSurface of Interior Coatingsin an EnvironmentalChamber”), SoundBreakGypsum Board achieved ascore of 10, the bestpossible score for this test.

**MOLD AND MILDEWRESISTANCE

SoundBreak Gypsum Boardwas designed to provideextra protection againstmold and mildewcompared to standardgypsum board products.

SURFACE BURNING CHARACTERISTICS

ASTM E 84Flame spread: 15Smoke developed: 0

WEIGHTSoundBreak - 2.7 lbs/SF

FIRE RESISTANCE RATINGSAs an option, SoundBreak

Gypsum Board may beused as an additional layeron one or both sides of fire-rated wall assemblies (i.e.,U300, W300, U400, W400and V400 series designs).SoundBreak Gypsum Boardcannot be used as asubstitute for 5/8" Type Xgypsum board in a fire-related assembly.

SoundBreak Gypsum Boardshall be attached inaccordance withmanufacturer’srecommendations. WhenSoundBreak Gypsum Boardis installed between theframing and the UL/ULCClassified gypsum board,the UL/ULC Classifiedgypsum board layer(s)required for the designis/are to be installed asindicated in the design asto fastener type andspacing, except that therequired fastener lengthshall be increased by aminimum of 5/8" (16 mm).

For U300, W300, U400,W400 and V400 seriesdesigns, outer layer treatedwith joint compound andpaper tape as specified inthe design.

For additional information goto UL/ULC OnlineCertifications Directories,Product Category CodeCLBV.R25426 – Wall andPartition Facings andAccessories.

TECHNICAL DATA

Mold and MoistureResistant FacePaper

ViscoelasticPolymer

Mold andMoisture Resistant

Back PaperEnhancedHigh Density

Mold Resistant Core

For additional information go towww.SoundBreak.info.

Page 29: Ngc Gyp Wall Board

85NATIONAL GYPSUM WALLBOARD PRODUCTS

09

29

00

09 29 00/NGC

Installation of SoundBreakGypsum Board should beconsistent with methodsdescribed in the standardsand references noted.

Stagger SoundBreak GypsumBoard joints from one side ofthe wall to another.

Allow a 1/4" gap along allperimeter edges andcompletely seal 1/4" gap withacoustical sealant or caulk.

Refrain from wall penetrationswhen possible.

Limit necessary wallpenetrations to one per studcavity.

Seal all penetrations withacoustical sealant and/orputty pads.

The use of SoundBreak GypsumBoard in actual installationsmay not produce the sameresults as were achieved incontrolled, laboratoryconditions.

Use an acoustical sealant that isapplied per ASTM C919,such as Grabber AcousticalSealant GSC, STI SpecSealSmoke N Sound Caulk, BOSS824 Acoustical Sound Sealantor equivalent.

Use a putty pad that has beentested per ASTM E90, such asSTI SpecSeal SSP Putty Padsor BOSS 818 Fire-Rated PuttyPads or equivalent.

Exposure to excessive orcontinuous moisture andextreme temperatures shouldbe avoided. SoundBreakGypsum Board is notrecommended where it willbe exposed to temperaturesexceeding 125˚ (52˚C) forextended periods of time.

SoundBreak Gypsum Board isfor use in wall assemblies.

Installing SoundBreak GypsumBoard panels over aninsulating blanket, installedcontinuously across the faceof the framing members, isnot recommended. Blanketsshould be recessed andflanges attached to the sidesof the studs.

RECOMMENDATIONS

SPECIFICATIONSSoundBreak Gypsum Boardmust be stored off the groundand under cover. Sufficientrisers must be used to ensuresupport for the entire lengthof the gypsum board toprevent sagging.

SoundBreak Gypsum Boardmust be kept dry to minimizethe potential for moldgrowth. Adequate careshould be taken whiletransporting, storing, applyingand maintaining SoundBreakGypsum Board. Foradditional information, referto the Gypsum Associationpublication, “Guidelines forthe Prevention of MoldGrowth on Gypsum Board”(GA-238-03), which isavailable atwww.gypsum.org under the“Download Free GypsumAssociation Publications”section.

DECORATIONFor best painting results, all

surfaces, including jointcompound, should be clean,dust-free and not glossy. Toimprove fastener and jointconcealment, a coat ofquality drywall primer isrecommended to equalizethe porosities betweensurface paper and jointcompound.

The selection of a paint to givethe specified or desiredfinished characteristics is theresponsibility of the architector contractor.

SoundBreak Gypsum Board thatis to have a wall coveringapplied should be preparedand primed as described forpainting.

Gypsum Association GA-214,Recommended Specificationfor Levels of Gypsum BoardFinish, should be referred toin order to determine thelevel of finishing required toensure a properly preparedsurface that accepts thedesired decoration.

PART 2 PRODUCTSTHE FOLLOWING PARAGRAPHS ARE

FOR INSERTION INTO SECTIONS OFGENERIC SPECIFICATIONS ORGENERIC/PROPRIETARYSPECIFICATIONS COVERINGGYPSUM BOARD PRODUCTS. THENATIONAL GYPSUM PRODUCTNAME FOLLOWS THE GENERICDESCRIPTION IN PARENTHESES.

2.01 MATERIALSA. Acoustically Enhanced Mold

and Mildew ResistantGypsum Board: A gypsumcore wall panel with aconstrained viscoelasticpolymer center layer; surfacedwith moisture/mold/mildewresistant paper on front, backand long edges andcomplying with ASTM C1396 (Gold Bond® BRANDSoundBreak Gypsum Board)1. Thickness: 5/8"2. Width: 4' 3. Length: 8' , 9' , 10' or 12' 4. Edges: Tapered5. Mold and Mildew

Resistance: Panel Scoreof 10 when tested in Accordance with ASTMD 3273

PART 3 EXECUTION3.01 INSTALLATIONA. General: In accordance

with the manufacturer’srecommendations,National Gypsum Company “Gypsum Construction Guide.”

Page 30: Ngc Gyp Wall Board

86 NATIONAL GYPSUM BOARD PRODUCTS

Gridstone® BRAND Ceiling Panels

DESCRIPTION TECHNICAL DATA

Gridstone® BRAND prefinished ceiling panels have a non-combustible, Fire-Shield G gypsum core. The 2-mil white, stipple-textured vinyl laminate combines high light reflectance with easy cleanability.

Gridstone panels can be used for interior and exterior ceiling applications.

Gridstone Ceiling Panels install easily in standard 2' x 2' and 2' x 4' exposed grid systems. Ceiling panelshave a rigid gypsum core which provides extra resistance to sagging and warping.

A noncombustible gypsum core ensures fire safety with1 1/2- and 2-hour fire rating achievable depending on installation.

The sturdy white vinyl laminate eliminates additional finishing.

As little as 1" of material can be cut from Gridstone panels with practically none of the crumbling common with mineral fiberpanels.

For exterior application, protect grid panels from direct exposure to weather, water and continuous high humidity. Under no circumstances should water be in contact with the back of the panels.

Overlaid insulation may causeexcessive panel deflection and is not recommended where high humidity is likely to occur.

Extreme lighting conditions may distort texture appearance.

The use of strong organic solvents (such as ketones), harsh abrasive cleansers or steel wool are not recommended. These materials may cause dulling, discoloration, softening and other permanent damage to the vinyl surface.

USDA Acceptance: Gridstone panels are accepted by the USDA for use in food service and food processing areas.

RECOMMENDATIONS

Gridstone ceiling panels are designed to be mounted in standard 15/16" exposed tee grid systems or environmental type grids for severe conditions, with grids either 2' x 2' or 2' x 4'. Grid installation should be conducted according to manufacturer's specifi-cation.

Each panel must be supported on all four (4) edges.

Cross ventilation must be provided in unheated or enclosed space above ceiling panels.

General: Install panels in lay-in suspension systems with edges concealed by flanges of suspension members. Cut boards to fit tightly at borders and penetrations sothat cut edges are concealed by trim pieces and escutcheons.

Cleaning: Common dirt and stains on the vinyl surface can be removed with mild soap or detergent in lukewarm water. Use a light, scrubbing action with a cloth, sponge or soft brush.

If the suitability of any cleaning agent is unknown, check its effect on the Gridstone panel surface in a hidden area or on a scrap piece before attempting to remove a field stain.

Gridstone Ceiling Panels are not recommended for use in areas exposed to extreme or continuous moisture such as found in saunas, steam rooms, gang shower rooms or indoorpool enclosures, per ASTM C840 17.3.1.1.

DECORATIONGridstone Brand Ceiling

Panels are factory-finished decorative products which do not require painting. However, if desired, Gridstone can be painted with the following two products:1. Two coats of an alkyd or

latex enamel.2. Oil primer with finish

coat of oil or latex paint.3. Two coats of latex paint.

Vinyl laminate on face of 2' x 2' Gridstone panel is directional. Install with all factory edges parallel (same direction).

A. Specification ComplianceGridstone panels conform to ASTM C 1396 Type X Class I.B. Light ReflectanceLRI (75% or greater)C. Sound Attenuation(Per ASTM E1414)

D. AbrasionWet: (Gardner Scrub Tester) 2000 oscillations with no film

break-through and only minor erosions.Dry: (Taber Abrasion Test with CS-17 Wheel) 500 cycles with no

break-through to the substrate.E. Surface Burning Characteristics

(Per ASTM E 84)

F. Weight1/2" FSW-G - 2.18 lbs/SF

G. Fire Rating(Per ASTM E 119)

Type Thickness Construction CAC NGC Report #

Gridstone 1/2" FSW-G Continuous 46dB 6098001(12.7 mm)

Flame SmokeType Spread Developed Class TestGridstone 5 0 A WHI 694-0700.7

NominalType Thickness Size Design* Rating

Gridstone 1/2" FSW-G 2' x 2' UL G222 2 hr.(12.7 mm) (610 mm x 610 mm) FM FC-299

1/2" FSW-G 2' x 4' UL G259 1 1/2 hr.(12.7 mm) (610 mm x 1219 mm) FM FC-300

*See Quick Selector, page 25, for fire rated assembly details.

Page 31: Ngc Gyp Wall Board

87NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

Reference Gridstone technical data on page 86.

Gridstone CleanRoom Ceiling Panels are designed to be used in a gasket seal suspended grid system using hold down clips.

Recommended use of Gordon DS-20 gasket Seal System or equivalent gasket sealed grid systems designed for clean room applications. Grid installation should be conducted according to manufacturer's specification.

Each panel must be supported on all four (4) edges.

Cross ventilation must be provided in unheated or enclosed space above ceiling panels.

General: Install panels in lay-in suspension systems with edges concealed by flanges of suspension members. Cut panels to fit tightly at borders and penetrations so that cut edges are concealed by trimpieces and escutcheons.

If panel cuts are required, exposed core should be sealed to maintain performance of the system.

Cleaning: Common dirt and stains on the vinyl surface can be removed with mild soap or detergent in lukewarm water. Use a lightscrubbing action with a cloth, sponge or soft brush.

If the suitability of any cleaning agent is unknown, check its effect on the Gridstone CleanRoom panel surface in a hidden area or on a scrap piece before attempting to removea field stain.

Vinyl laminate on face of 2' x 2' Gridstone CleanRoom panel is directional. Install with all factory edges parallel (same direction).

THE FOLLOWING PARAGRAPHSARE FOR INSERTION INTO SECTIONSOF GENERIC SPECIFICATIONS ORGENERIC/PROPRIETARYSPECIFICATIONS COVERING GYPSUMBOARD PRODUCTS. THE NATIONALGYPSUM PRODUCTS NAMEFOLLOWS THE GENERICDESCRIPTION IN PARENTHESES.

PART 22.02 MATERIALS

A. Fire-Resistant Sealed Vinyl Laminated GypsumGrid Board: A gypsum core lay-in ceiling panel with additives to enhancesag and fire resistance of the core. Panels are sealed on face, back and long edges with a 2-mil rigid vinyl film and exposed edges are factorysealed with a durable coating providing a completely sealed panel; and complying with ASTM C 1396, type X; Class 1; E 1264, type XX, Patterns E, G.Federal Standard 209E “Airborne Particulate Cleanliness Classes in Clean Rooms and Clean Zones.” (Gridstone BRANDCleanRoom Ceiling Panels).

1. Thickness: 1/2"2. Width and length:

2' x 2' 2' x 4'

PART 33.03 INSTALLATION

A. Install panels in lay-in suspension systems with edges concealed by flanges of suspension members. Cut panels to fit tightly at borders and penetrations so that cut edges are concealed by trim pieces and escutcheons.

PACKAGING2' x 2' – 4 pcs./bundle, 16 sq.

ft., 80 bundles/UnitCatalog Code – GB5044

2' x 4' – 4 pcs./bundle, 32 sq.ft., 40 bundles/UnitCatalog Code – GB5045

All bundles are double-wrapped with long corner protectors.

PACKAGING2' x 2' – 4 pcs./bundle, 16 sq.

ft., 80 bundles/UnitCatalog Code – GB5040

2' x 4' – 4 pcs./bundle, 32 sq. ft., 40 bundles/UnitCatalog Code – GB5030

All bundles are double-wrapped with long cornerprotectors.

THE FOLLOWING PARAGRAPHS AREFOR INSERTION INTO SECTIONS OFGENERIC SPECIFICATIONS ORGENERIC/PROPRIETARYSPECIFICATIONS COVERINGGYPSUM BOARD PRODUCTS. THENATIONAL GYPSUM PRODUCTNAME FOLLOWS THE GENERICDESCRIPTION IN PARENTHESES.PART 22.02 MATERIALS

A. Fire Resistant Vinyl Laminated Gypsum Grid Board: A gypsum core lay-in ceiling board with additives to enhance sag and fire resistance of the core; surfaced with paper on the front and back and finished on the front with a 2 mil, white, stipple textured vinyl laminate; and complying with ASTM C 1396, type X; Class 1; E 1264, type XX, patterns E, G. (Gridstone Brand Ceiling Panel).

1. Thickness: 1/2"2. Width and Length:

2' x 2' 2' x 4'

PART 33.03 INSTALLATION

A. Install boards in lay-in suspension systems with edges concealed by flanges of suspension members. Cut panels to fit tightly at borders and penetrations so that cut edges are concealed by trim pieces and escutcheons.

SPECIFICATIONS

DESCRIPTION SPECIFICATIONS

RECOMMENDATIONS

GRIDSTONE® BRAND CLEANROOM CEILING PANELS

TECHNICAL DATA

Gridstone BRAND CleanRoom Ceiling Panels aresealed on the face, back and long edges with a 2 mil rigid vinyl film. The exposed edges are factory sealed with a durable coating providing a completely sealed panel.

Gridstone CleanRoom panels are for use in systems designed for areas requiring high levels of air cleanlinessfor airborne particulate levels such as clean rooms and clean zones.Designed for clean room use. Approved for use in systems, Class 100,000, Class 10,000, Class 1,000, Class 100 per Federal Standard 209E “Airborne Particulate Cleanliness Classes in Clean Rooms and Clean Zones.”Fire-resistant. A non-combustible gypsum core ensures fire safety with 1 1/2 and 2-hour fire rating achievable depending on installation.Sag-resistant. Gridstone CleanRoom panels’ rigid gypsum core prevents sagging and warping problems and is backed by a 15-year limited warranty.Do not install panels in areas exposed to continuous high humiditysuch as saunas, steam rooms, gang showers, and indoor pools per ASTM C840, 17.3.1.1.Overlaid insulation may cause excessive panels deflection and is not recommended where high humidity is likely to occur.Extreme lighting conditions may distort texture appearance.The use of strong organic solvents (such as ketones), harsh abrasive cleansers or steel wool are not recommended. These materials may cause dulling, discoloration,softening and other permanent damage to the vinyl surface.Gridstone CleanRoom panels are USDA accepted for use in food service and food processing areas.

Page 32: Ngc Gyp Wall Board

88 NATIONAL GYPSUM BOARD PRODUCTS

Gridstone® BRAND Hi-Strength prefinished ceiling panels have a non-combustible high strength gypsum core formulated with increased uniformity and integrity which increases its sag resistance.

Gridstone Hi-Strength panels can be used for interior and exterior ceiling applications in protected, well-ventilatedspaces that receive intermittent exposure to moisture.Lightweight. Gridstone Hi-Strength 5/16" panels are 40% lighter in weight than standard gypsum ceiling panels.Quick, dry installation.Gridstone Hi-Strength Ceiling panels score and snap clean and install easily in standard exposed grid systems.Pre-decorated. The sturdy white vinyl laminate eliminates additional finishing.Do not install panels in areas exposed to continuous high humidity such as saunas, steam rooms, gang showers, and indoor pools per ASTM C840, 17.3.1.1.For exterior application, protect grid panels from direct exposure to weather, water and continuous high humidity. Under no circumstances should water be in contact with the back of the panels.Overlaid insulation may cause excessive panel deflection and is not recommended. These materials may cause dulling, discoloration, softening and other permanent damage to the vinyl surface.Gridstone Hi-Strength panels are not listed in fire-rated assemblies.

USDA Acceptance: Gridstone Hi-Strength panels are accepted by the USDA for use in food service and foodprocessing areas.

DECORATIONGridstone Hi-Strength Ceiling

panels are factory-finished decorative products which do not require painting. However, if desired, Gridstone can be painted with the following products:

1. Two coats of alkyd or latex enamel.

2. Oil primer with finish coat of oil or latex paint.

3. Two coats of latex paint.

Gridstone Hi-Strength ceiling panels are designed to be mounted in standard 15/16"exposed tee grid systems or environmental type grids for severe conditions, with grids either 2' x 2' or 2' x 4'. Grid installation should be conducted according to manufacturer'sspecification.

Each panel must be supported on all four (4) edges.

Cross ventilation must be provided in unheated or enclosed space above ceiling panels.

General: Install panels in lay-in suspension systems with edges concealed by flanges of suspension members. Cutpanels to fit tightly at borders and penetrations so that cut edges are concealed by trim pieces and escutcheons.

Cleaning: Common dirt and stains on the vinyl surface can be removed with mild soap or detergent in lukewarm water. Use a lightscrubbing action with a cloth, sponge or soft brush.

If the suitability of any cleaning agent is unknown, check its effect on the Gridstone Hi-Strength panelsurface in a hidden area before attempting to removea field stain.

NOTE: Vinyl laminate on face of 2' x 2' Gridstone Hi-Strength panel is directional. Install with all factory edges parallel (same direction).

THE FOLLOWING PARAGRAPHS AREFOR INSERTION INTO SECTIONS OFGENERIC SPECIFICATIONS ORGENERIC/PROPRIETARY SPECIFICATIONSCOVERING GYPSUM BOARDPRODUCTS. THE NATIONAL GYPSUMPRODUCT NAME FOLLOWS THE GENERICDESCRIPTION IN PARENTHESES.

PART 22.02 MATERIALS

A. Vinyl laminated Gypsum Grid board: A gypsum core lay-in ceiling panel with additives to enhance sag resistance of the core; surfaced with paper on the front and back and finished on the front with a 2 mil, white, stipple textured vinyl laminate; and complying with ASTM C 1396, Class 1, E 1264 Type XX, Patterns E, G (Gridstone BRAND Hi-Strength Ceiling Panels)

1. Thickness: 5/16"2. Width and length:

2' x 2' 2' x 4'

PART 33.03 INSTALLATION

A. Install panels in lay-in suspension systems with edges concealed by flanges of suspension members. Cut panels to fit tightly at borders and penetrations so that cut edges are concealed by trim pieces and escutcheons.

SURFACE BURNINGCHARACTERISTICS

ASTM E 84Flame Spread: 5Smoke Developed: 0

WEIGHT5/16" Hi-Strength - 1.24 lbs/SF

SOUND ATTENUATIONASTM E 1414 Test MethodCeiling Attenuation Class

(CAC)-41 dB

LIGHT REFLECTANCELR 1 (75% or greater)

Gridstone® BRAND Hi-Strength Ceiling Panels

TECHNICAL DATADESCRIPTION

RECOMMENDATIONS

SPECIFICATIONS

PACKAGING2' x 2' – 6 pcs./bundle, 24 sq.

ft., 80 bundles/UnitCatalog Code – GB5020

2' x 4' – 6 pcs./bundle, 48 sq. ft., 40 bundles/UnitCatalog Code – GB5010

All bundles are double-wrapped with long cornerprotectors.

Page 33: Ngc Gyp Wall Board

09 29 00/NGC

89NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

Gold Bond® BRAND Foil Back Gypsum Board

DESCRIPTION LIMITATIONS1. Not recommended for

use where exposure to moisture and high outside temperature is extreme and continuous. Under these conditions, a qualified mechanical engineer should determine location of the vapor retarder.

2. Not to be used as a base for ceramic or other tile or as a base layer for prefinished vinyl wall boards in double-layer assemblies. Also, not to be used as a base for adhesively applied vinyl or other highly water-vapor-resistant wall coverings.

3. To prevent objectionable sag in ceilings, weight of overlaid unsupported insulation should not exceed:1.3 lb./sq. ft. for 1/2" thick boards with frame spacing 24" o.c.; 2.2 lb./sq. ft. for boards with frame spacing 16" o.c. Boards 3/8" thick must not be overlaid with unsupported insulation. Unheated attic spaces shouldbe properly ventilated.

4. Foil Back Gypsum Board is not recommended for use in hot, humid, climates such as the Southern Atlantic and Gulf Coast areas.

MATERIALSManufactured boards with

gypsum core, paper-encased with aluminum foil laminated backing.

SIZES AND TYPESThickness Width Length

1/2" 4' 6' to 16'5/8" 4' 6' to 16'

Edges: Square, tapered or Sta-Smooth.

APPLICABLE STANDARDSASTM C 1396

Gold Bond® Foil Back Gypsum Board consist of a fire-resistive gypsum core encased in heavy natural-finish paper on the face side and strong liner paper on the backside to which aluminum foil is laminated. The ends are square cut and finished smooth.

BASIC USESFoil Back Gypsum Board can be

used for exterior walls and ceilings in new construction and remodeling. The aluminum foil, laminated to the back surface, is a vapor retarder to keep interior moisture within the building at a suitable comfort level. Foruse with furred masonry, wood or steel framing, Gold Bond Foil Back Gypsum Board is effective for single-layer applications and as a base layer in double-layer applications where a vapor retarder of 1.0 perm or less is required.

ADVANTAGES1. In tests conducted according

to ASTM Test Procedure E 96 (desiccant method), 1/2" Foil Back Gypsum Board showed a performance of 0.06 perm compared to 34 perm for1/2" regular gypsum board and 28 perm for 1/2" gypsum board with two coats of flat latex paint.

2. In-place cost of Foil Back Gypsum Board installation is lower per thousand sq. ft. than a similar installation for regular gypsum board and polyethylene-film retarder installed separately.

3. Easy-to-handle Foil Back Gypsum Board is adaptable tovirtually all exterior wall and ceiling construction: wood frame, furred masonry.

Boards of maximum practical length should be used so that an absolute minimum number of end joints occur. Board edges should be brought into contact with each other but should not be forced into place.

Gypsum board joints at openings should be located so that no end joint will align with edges of openingsunless control joints will be installed at these points. End joints should be staggered, and joints on opposite sides of a partition should not occur on the same stud.

Gypsum board should be held in firm contact with the framing member while fasteners are being driven. Fastening should proceed from center portion of the gypsum board toward the edges and ends. Fasteners should be set with the heads slightly below the surface of the gypsum board in a dimple formed by the hammer or power screwdriver. Care should be taken to avoid breaking the face paper of the gypsum board. Improperly driven nails or screws shall be removed.

For best painting results, all interior surfaces, including joint compound, should be clean, dust-free and not glossy. To improve fastener and joint concealment, a prime coat of drywall primer is recommended to equalize the porosities between surface paper and joint compound.

See page 63, Environmental Conditions and Limitations.

TECHNICAL DATA

SURFACE BURNINGCHARACTERISTICS

(ASTM E 84)Flame spread: 15Smoke developed: 0

WEIGHT1/2" Regular - 1.6 lbs/SF5/8" Type X - 2.2 lbs/SF

FIRE RESISTANCE RATINGSFoil Back Gypsum Board has

not been used in fire resistance tests. Fire resistance ratings represent the results of tests on assemblies made up of specific materials in a specific configuration. When selecting construction designs tomeet certain fire resistance requirements, caution must be used to ensure that each component of the assembly is the one specified in the test. Further, precaution should be taken that assembly procedures are in accordance with that of the tested assembly. (For copies of specific tests, call 1-800-NATIONAL or 1-800-628-4662.)

RECOMMENDATIONS

Examine and inspect materialsto which gypsum board is to be applied. Remedy all defects prior to installation of gypsum board. Any defects in the finished installation due to misaligned framing or other cause will be the responsibility of the work performed under that section of the specification and such defects shall be remedied under that secton of the specification

Gypsum board should be applied first to ceiling at

right angles to framing members, then to walls.

Page 34: Ngc Gyp Wall Board

90 NATIONAL GYPSUM BOARD PRODUCTS

GYPSUM SYSTEMSNonload-Bearing Steel Frame Partitions

DESCRIPTION

Steel framed drywall partitionsare comprised of steel floorand ceiling tracks, steelstuds and Gold BondGypsum Board which isattached with self-drillingdrywall screws. Metalproducts are to meet orexceed all applicableASTM standards.

Gypsum board may beapplied horizontally orvertically in single ordouble layers. In doublelayer construction, the face,or finish layer, may beDurasan panels adhesivelyapplied to the base layer.For specific fire and soundratings for this system, seetest data on pages 11through 26.

ADVANTAGES1. Openings provided

throughout the length ofthe steel studs permit theeasy horizontal routing ofwater, gas and electricalconduit. These openingsmay also be used to installC.R. Channel stiffenerswhere increased rigidity isrequired. Interruption of thefloor or ceiling track allowsthe vertical installation oflarger utilities.

2. Fire resistance: 1-, 2-, 3-and 4-hour fire ratings havebeen assigned to thesesystems (see pages 11-26).

3. Sound resistance: where a superior SoundTransmission Class isrequired, it can beachieved through the use of several variations withthis system.

TECHNICAL DATA

PARTITION HEIGHTSLight Gauge Steel Studs are

designed to frame nonload-bearing partitions whichare limited in height bydeflection resulting fromextraneous horizontalforces. For any givenhorizontal load, the amountof deflection increases asthe height of the partitionincreases.

Tables 1 and 2 on the nextpage show maximumpartition heights based onspecific design criteria. Theheight limits shown arebased on the gypsum board

and the steel studs acting asa composite section toprovide a maximumdeflection of L/120, L/240,L/360 (L = partition height ininches) with a horizontalload of 5 psf, 7.5 psf, and10 psf of partition surface.

Increased rigidity may beobtained by placingstiffener channels throughthe steel stud cut-outs, byusing two layer applicationof gypsum board or bydecreasing stud spacing.

Standard 25 and 20 gaugestuds, recommended forinterior partitions, haveheight limits as shown inTables 1 and 2. Gypsumboard must be attached tofull height on both sides ofstuds with Type S BugleHead Drywall Screws(Type S-12 for 20 gaugestuds) spaced not morethan 12" o.c. on all studswhen framing is 24" o.c.and 16" o.c. if framing is16" o.c. or less. Screwlengths must be not lessthan 3/8" greater than thetotal thickness of thegypsum board beingfastened.

Light steel 20 gauge studs aredesigned for exterior,nonload-bearing curtainwall systems, but are alsoused for interior partitionsto provide more ridigity orgreater heights than can beobtained with Standard 25gauge studs.

LIMITATIONS1. Maximum stud spacing for

single layer application of1/2" and 5/8" gypsumboard is 24" o.c. If 3/8"gypsum board is used, itmust be applied in twolayers, with the secondlayer adhesively applied;24" o.c. stud spacing maybe used.

2. Where long, continuousruns of this wall system areemployed, control jointsmust be provided every 30'or less.

3. Where structural movementmay impose direct loads onthese systems, isolationdetails are required.

4. Partitions should not beused where frequentlyexposed to excessivemoisture unless all surfaces

are waterproofed.5. To prevent weakening

due to calcining, gypsumboard should not beexposed to temperaturesover 125˚F for extendedperiods of time.

6. Gypsum board joints onsingle layer, or the facelayer on two layerapplications, shall notoccur within 12" of thecorners of door framesunless control joints areinstalled at the corners.

7. For limitations regardingselection of doors anddoorframes, refer to tableon page 92.

8. Where reference is madeto nominal gauges, 25gauge relates to aminimum base steel of.0179", and 20 gauge to.0329".

Page 35: Ngc Gyp Wall Board

91NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGC

25 GAUGE STUDS/PARTITION LIMITING HEIGHTSStud Stud Deflection Lateral Pressure

5 psf 7.5 psf 10 psfDepth Spacing Limit (240 Pa) (360 Pa) (480 Pa)

1-5/8 in. 12 in. L/120 11-2 (3400) 9-9 (2970) 8-10 (2690)(41.3mm) (305mm) L/240 8-10 (2690)

L/36016 in. L/120 10-7 (3230) 8-10 (2690) 8-4 (2540)

(406mm) L/240 8-4 (2540)L/360

24 in. L/120 9-9 (2970) 8-0 (2440)(610mm) L/240 7-11 (2410)

L/3602-1/2 in. 12 in. L/120 15-1 (4600) 12-4 (3760) 10-9 (3280)(63.5mm) (305mm) L/240 11-11 (3630) 10-5 (3180) 9-6 (2900)

L/360 10-5 (3180) 9-1 (2770)

16 in. L/120 13-3 (4040) 10-10 (3300) 9-5 (2570)(406mm) L/240 11-3 (3430) 9-10 (3000) 8-11 (2720)

L/360 9-10 (3000) 8-7 (2620)

24 in. L/120 11-10 (3610) 9-8 (2950) 8-5 (2570)(610mm) L/240 10-7 (3230) 9-3 (2820) 8-5 (2570)

L/360 9-3 (2820) 8-1 (2460)

3-1/2 in. 12 in. L/120 17-8 (5380) 14-3 (4340) 12-5 (3780)(88.9mm) (305mm) L/240 15-4 (4670) 13-3 (4040) 12-0 (3660)

L/360 13-3 (4040) 11-7 (3530) 10-5 (3180)

* l6 in. L/120 15-4 (4670) 12-5 (3780) 10-9 (3280)(406mm) L/240 14-4 (4370) 12-5 (3780) 10-9 (3280)

L/360 12-4 (3760) 10-10 (3300) 9-9 (2970)

24 in. L/120 13-9 (4190) 11-0 (3350) 9-5 (2870)(610mm) L/240 13-5 (4090) 11-0 (3350) 9-5 (2870)

L/360 11-7 (3530) 10-1 (3070) 9-1 (2770)

4 in. 12 in. L/120 19-6 (5940) 15-9 (4800) 13-8 (4170)(101.6mm) (305mm) L/240 16-5 (5000) 14-4 (4370) 13-0 (3960)

L/360 14-4 (4370) 12-6 (3810) 11-4 (3450)

16 in. L/120 17-2 (5230) 13-10 (4220) 11-11(3630)(406mm) L/240 15-4 (4670) 13-4 (4060) 11-11(3630)

L/360 13-4 (4060) 11-8 (3560) 10-6 (3200)

24 in. L/120 15-1 (4600) 12-1 (3680) 10-5 (3180)(610mm) L/240 14-2 (4320) 12-1 (3680) 10-5 (3180)

L/360 12-4 (3760) 10-9 (3280) 9-9 (2970)

6 in. 12 in. L/120 22-10 (6960) 18-7 (5660) 16-2 (4930)(152.4mm) (305mm) L/240 22-1 (6730) 18-7 (5660) 16-2 (4930)

L/360 19-4 (5890) 16-9 (5110) 15-0 (4570)

16 in. L/120 19-9 (6020) 16-2 (4930) 14-0 (4270)(406mm) L/240 19-9 (6020) 16-2 (4930) 14-0 (4270)

L/360 17-11 (5460) 15-7 (4750) 3-10 (4220)

24 in. L/120 16-9 (5110) 13-5 (4090) 11-5 (3480)(610mm) L/240 16-9 (5110) 13-5 (4090) 11-5 (3480)

L/360 16-9 (5110) 13-5 (4090) 11-5 (3480)

Table 1

Note: Limiting height tables adapted with permission from ASTM C 754. Copyright ASTM.Tables based on tests conducted with gypsum board attached with screws 12" o.c. to framing.

*Applicable for 3 5/8" stud depth.

20 GAUGE STUDS/PARTITION LIMITING HEIGHTSStud Stud Deflection Lateral Pressure

5 psf 7.5 psf 10 psfDepth Spacing Limit (240 Pa) (360 Pa) (480 Pa)

1-5/8 in. 12 in. L/120 13-0 (3960) 11-4 (3450) 10-4 (3150)(41.3mm) (305mm) L/240 10-4 (3150) 9-0 (2740)

L/360 9-0 (2740)16 in. L/120 12-1 (3680) 10-7 (3230) 9-8 (2950)

(406mm) L/240 9-8 (2950) 8-5 (2570)L/360 8-5 (2570)

24 in. L/120 11-0 (3350) 9-7 (2920) 8-9 (2670)(610mm) L/240 8-9 (2670) 7-8 (2340)

L/360 7-8 (2340)2-1/2 in. 12 in. L/120 17-9 (5410) 15-6 (4720) 13-11 (4240)(63.5mm) (305mm) L/240 13-11 (4240) 12-1 (3680) 10-11 (3300)

L/360 12-1 (3680) 10-6(3200) 9-5 (2870)

16 in. L/120 16-5 (5000) 14-4 (4370) 12-10 (3910)(406mm) L/240 12-10 (3910) 11-2 (3400) 10-0 (3050)

L/360 11-2 (3400) 9-8 (2950) 8-8 (2640)

24 in. L/120 14-10 (4520) 13-0 (3960) 11-7 (3530)(610mm) L/240 11-7 (3530) 10-0 (3050) 8-11 (2720)

L/360 10-0 (3050) 8-7 (2620) 7-8 (2340)

3-1/2 in. 12 in. L/120 22-6 (6860) 19-8 (5990) 17-10 (5440)(88.9mm) (305mm) L/240 17-10 (5440) 15-6 (4720) 14-1 (4290)

L/360 15-6 (4720) 13-7 (4140) 12-4 (3760)

* 16 in. L/120 20-8 (6300) 18-1 (5510) 16-5 (5000)(406mm) L/240 16-5 (5000) 14-3 (4340) 12-11 (3940)

L/360 14-3 (4340) 12-6 (3810) 11-4 (3450)

24 in. L/120 18-6 (5640) 16-2 (5840) 14-9 (4500)(610mm) L/240 14-9 (4500) 12-9 (3890) 11-7 (3530)

L/360 12-9 (3890) 11-2 (3400) 10-1 (3070)

4 in. 12 in. L/120 25-1 (7650) 21-11 (6680) 19-11(6070)(101.6mm) (305mm) L/240 19-11 (6070) 17-4 (5280) 15-8 (4780)

L/360 17-4 (5280) 15-0 (4570) 13-7 (4140)

16 in. L/120 23-1 (7040) 20-2 (6150) 18-4 (5590)(406mm) L/240 18-4 (5590) 15-11 (4850) 14-5 (4390)

L/360 15-11 (4850) 13-9 (4190) 12-6 (3810)

24 in. L/120 20-9 (6320) 18-1 (5510) 16-5 (5000)(610mm) L/240 16-5 (5000) 14-3 (4340) 12-10 (3910)

L/360 14-3 (4340) 12-4 (3760) 11-2 (3400)

6 in. 12 in. L/120 33-9 (10290) 29-6 (8990) 26-9 (8150)(152.4mm) (305mm) L/240 26-9 (8150) 23-5 (7140) 21-3 (6480)

L/360 23-5 (7140) 20-6 (6250) 18-7 (5660)

16 in. L/120 30-10 (9400) 27-0 (8230) 24-6 (7470)(406mm) L/240 24-6 (7470) 21-4 (6500) 19-5 (5920)

L/360 21-4 (6500) 18-9 (5720) 17-0 (5180)

24 in. L/120 27-2 (8280) 23-10 (7260) 19-1 (5820)(610mm) L/240 21-7 (6580) 18-10 (5740) 17-3 (5260)

L/360 18-10 (5740) 16-7 (5050) 15-0 (4570)

Table 2

Page 36: Ngc Gyp Wall Board

92 NATIONAL GYPSUM BOARD PRODUCTS

SINGLE LAYER CONSTRUCTION

FASTEN JAMB STUDS TO TRACK TOP AND BOTTOM

TRACK - CUT ANDBENT DOWN

STEEL DOORFRAME

C.R. CHANNEL STIFFENERSFRICTION FIT(OPTIONAL)

JAMBANCHORS

FRAMING REQUIREMENTS AT DOORS

(Type of Door Frame) (Special Details) Partition Height Limits*Jamb Steel Studs Knock Knock Bracing Requires Stud Size

Door Min. Down Down Fixed Over Mechanical 1 5/8" 2 1/2" 3 5/8" 4" 6"Weight Base Steel, In. Alum. Steel Steel Headers Closure (41.3mm) (63.5mm) (92.1mm) (102mm) (152mm)

0.0179 x x x NA** 10'(3048mm) 14'(4267mm) 15'(4572mm) 14'(4267mm)0.0179 x x x x 10'(3048mm) 12'(3657mm) 16'(4876mm) 17'(5181mm) 16'(4876mm)

0.0329 x x x x – 16'(4876mm) 21'(6400mm) 22'(6705mm) 22'(6705mm)

0.0179 x x x – 10'(3048mm) 14'(4267mm) 15'(4572mm) 14'(4267mm)0.0179 x x x 10'(3048mm) 12'(3657mm) 14'(4267mm) 15'(4572mm) 14'(4267mm)0.0179 x x x 12'(3657mm) 14'(4267mm) 16'(4876mm) 17'(5181mm) 16'(4876mm)

0.0329 x 10'(3048mm) 14'(4267mm) 15'(4572mm) 15'(4572mm)0.0329 x x x 12'(3657mm) 16'(4876mm) 17'(5181mm) 17'(5181mm)0.0329 x x x 12'(3657mm) 16'(4876mm) 17'(5181mm) 17'(5181mm)

0.0329 dbl. web to web x 16'(4876mm) 21'(6400mm) 22'(6705mm) 22'(6705mm)0.0329 dbl. web to web x x 16'(4876mm) 21'(6400mm) 22'(6705mm) 22'(6705mm)

0.0179 x x x 12'(3657mm) 14'(4267mm) 15'(4572mm) 14'(4267mm)

0.0329 x x x x 12'(3657mm) 16'(4876mm) 17'(5181mm) 17'(5181mm)

0.0329 dbl. web to web x x 16'(4876mm) 21'(6400mm) 22'(6705mm) 22'(6705mm)

* For a specific partition having a door opening compare above partition height limits with height tables on page 88. The lower height table governs.** NA – Not Allowed.

80 lbs.(36 kg) to120 lbs.(54 kg)

50 lbs.(23 kg) to80 lbs.(36 kg)

Up to50 lbs.(23 kg)

CHASE WALL

20" MAX. WIDTHPER ASTM C754

16' MAX. HEIGHT

48"MAX.

12"

FACE GYPSUM BOARD (APPLIEDIN NORMAL MANNER)

TAPE AND JOINTCOMPOUND

3 DRYWALLSCREWSPER STUD

1/2" GYPSUMBOARD ORSTUD TRACK2 SCREWSPER STUD(ALTERNATE)

STEEL TRACK

Page 37: Ngc Gyp Wall Board

93NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGC

25 & 20 GAUGE STUDS ”C” shaped metal studs fabricatedfrom galvanized steel. 20 gaugestuds are for curtainwall con-struction or more rigid partitions.

25 & 20 GAUGE TRACKFastened at floor and ceiling tosupport the steel studs. Track is channel-shaped and fab-ricated from galvanized steel.

Drywall Metal Framing*

COLD ROLLED CHANNELUsed in suspended ceilings andas stiffeners in stud partitions.

FURRING CHANNELUsed as cross furring membersfor attachment of gypsum boardor lath on ceiling or furredmasonry walls.

RESILIENT FURRING CHANNELUsed as cross furring membersfor attachment of gypsum boardand improves sound isolation onceilings and partitions.

Z FURRING CHANNEL Generally used on the inside ofexterior masonry walls to supportrigid foam insulation and toprovide a fastening surface forgypsum board.

FLOOR & CEILING RUNNER 2" x 2" 20 GAUGEUsed as a utility floor and ceilingrunner. Also used in verticalshaftwall inside cornerapplication.

L RUNNERPerforated – Ceiling or floorsupport for 2" solid lath andplaster partition. Plain – Ceiling support for 2"solid gypsum board partitionusing 1" shaftliner.

*Metal products are not manufactured by National Gypsum Company

Page 38: Ngc Gyp Wall Board

94 NATIONAL GYPSUM BOARD PRODUCTS

GYPSUM BOARDCORNERBEADUsed to reinforce exteriorgypsum board corners. For usewith all gypsum boardthicknesses, single or doublelayer application.

ARCH CORNERBEAD Can be used straight for exteriorcorners or flanges, or may besnipped and bent to form arches.

E-Z STRIP® EXPANSION JOINTDesigned for drywall or veneerplaster systems. A vinylextrusion used as an expansionor control joint for ceilings orpartitions.

J GYPSUM BOARD CASING (Reveal Trim)Used at door, window, insidecorners when facing must beisolated from abutting elements.Requires no joint treatment finish.

J GYPSUM BOARD CASING Provides a finished edge at doorand window jambs by slippingover edge. Is face nailed andexposed surface finished withjoint treatment.

.093 ZINC CONTROL JOINTDesigned as an expansion orcontrol joint for ceiling andpartition areas for both drywall or veneer plaster systems.

L GYPSUM BOARD CASING Used as a finished edge at doorand window jambs. Is face nailedand exposed surface finishedwith joint treatment.

Accessories*

*Accessories are not manufactured by National Gypsum Company

Page 39: Ngc Gyp Wall Board

95NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGC

DETAILS

STEEL STUD

TAPE AND JOINTCOMPOUND

PARTITION INTERSECTION09250F

Scale: 3" = 1'-0"

GYPSUMBOARD

STEEL STUD

TAPE AND JOINTCOMPOUND

ALTERNATE PARTITIONINTERSECTION

09250GScale: 3" = 1'-0"

CORNER DETAIL09250E

Scale 3" = 1'-0"

3 5/8" STEEL STUDLOCATE AT ABUTTING WALLAND ATTACH THRU GYPSUMBOARD TO STUD INABUTTING WALL

CORNERBEAD – TYPICAL 5/8" GYPSUM BOARD – NUMBER OF LAYERS DETERMINED BY PARTITION TYPE

JOINT WHERE WALL FRAMING CHANGES09250CC

Scale: 3" = 1'-0"

MASONRY WALLSOR COLUMN

STEELSTUD

CAULKING

CASING

KAL-KORE ORGYPSUM BOARD

VENEER PLASTER OR JOINT COMPOUND ADHESIVE

E-Z STRIP VINYLEXPANSION JOINT

STUD SPLICE

16" LENGTH OFTRACK

STUDS BUTTED

4 PAN HEADSCREWS EACHSIDE

Page 40: Ngc Gyp Wall Board

96 NATIONAL GYPSUM BOARD PRODUCTS

ATTACHMENT TO CONCRETE SLAB09250H

Scale: 3" = 1'-0"

CAULK

DRYWALLCASING

STEEL STUD

CEILING TRACK

DOOR HEAD DETAIL - WOOD09250K

Scale: 3" = 1'-0"

WOOD TRIM

TRACK

STEEL STUD

JAMB STUD

DOOR JAMB DETAIL - WOOD09250N

Scale: 3" = 1'-0"

STEELSTUD

GYPSUMBOARD

WOOD BASE

RESILIENTCOVE BASE

FLOOR TRACKBASE DETAIL

09250QScale: 3" = 1'-0"

FURRING CHANNEL CLIP

FURRINGCHANNEL

STEEL STUD

ATTACHMENT TOSUSPENDED CEILING

09250IScale: 3" = 1'-0"

TAPE ANDJOINT

COMPOUND

TOGGLE BOLTOR MOLLY

1 1/2" C.R.CHANNEL

STEEL STUD TRACK

STEEL STUD

DOOR HEAD DETAIL - METAL09250L

Scale: 3" = 1'-0"

METAL FRAME

TRACK

DOOR JAMB DETAIL - METAL09250O

Scale: 3" = 1'-0"

STEEL STUD

JAMB ANCHOR CLIP

PARTITION END DETAIL09250R

Scale: 3" = 1'-0"

DRYWALL CORNERBEAD

ATTACHMENT TOFURRED CEILING

09250JScale: 3" = 1'-0"

DRYWALLCASING

TYPE SDRYWALLSCREW

FURRING CHANNEL

WALL CONTROL JOINT09250M

Scale: 3" = 1'-0"

SEALANT

E-Z STRIPCONTROL JOINT

BUTT JOINT DETAIL09250S

Scale: 3" = 1'-0"

STEELSTUD

TAPE AND JOINTCOMPOUND

E-Z STRIP VINYLEXPANSION JOINT

1/2"GAP5/8" FIRE-SHIELD

5/8" GAP

2 1/2" STEEL STUDS 5/8" FIRE-SHIELD STRIPS

1 5/8" DRYWALLSCREWS24" O.C.

ONE HOUR FIRE RATED CONTROL JOINT DETAILBased on Warnock Hersey Report No. WHI-651-0318.1

and Factory Mutual Design No. W 1B-1 hr.09250P

Scale: 3" = 1'-0"

Page 41: Ngc Gyp Wall Board

97NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGC

SPECIFICATIONS

THE FOLLOWING PARAGRAPHS ARE FOR INSERTION INTO SECTIONS OFGENERIC SPECIFICATIONS COVERING METAL FRAMING PRODUCTS.

VERIFY DESCRIPTIONS OF METAL FRAMING PRODUCTS WITHMANUFACTURER.

PART 2 PRODUCTS2.02 MATERIALS

A. METAL FRAMING1. Studs: 1 5/8", 1 1/2", 3 5/8", 4" and 6" C shaped studs,

weighing 312 lbs., 370 lbs., 448 lbs., 472 lbs., and 607lbs. per 1000 lin. ft. with min. base steel of 0.0179",galvanized, and complying with ASTM C 645.

2. Track: 1 5/8", 2 1/2", 3 5/8", 4" and 6" U shaped trackwith 1" legs, weighing 244 lbs., 303 lbs., 378 lbs., 404lbs. and 539 lbs. per 1000 lin. ft. with min. base metal of0.0179", galvanized and complying with ASTM C 645.

3. 1 5/8", 2 1/2", 3 5/8", 4" and 6" U shaped track with 11/4" legs, weighing 278 lbs., 337 lbs., 412 lbs., 438 lbs.and 572 lbs. per 1000 lin. ft. with min. base metal of0.0179", galvanized and complying with ASTM C 645.

4. Studs: 2 1/2", 3 5/8", 4" and 6" C shaped studs. Studsweighing 679 lbs., 817 lbs., 867 lbs. and 1105 lbs. per1000 lin. ft. with min. base metal of 0.0329", galvanizedand complying with ASTM C 645.

5. Track: 2 1/2", 3 5/8", 4" and 6" U shaped track with1.177" legs, weighing 604 lbs., 740 lbs., 785 lbs. and1027 lbs. per 1000 lin. ft. with min. base metal of0.0329", galvanized and complying with ASTM C 645.

6. Z Furring Channels: 1", 1 1/2" and 2" Z shaped channels,weighing 201 lbs., 236 lbs. and 268 lbs. per 1000 lin. ft.with min. base steel of 0.0179", galvanized andcomplying with ASTM C 645.

7. Floor & Ceiling Runner: L shaped runner weighing 545lbs. per 1000 lin. ft. with min. base steel of 0.0329",galvanized.

PART 3 EXECUTION3.01 INSTALLATION

A. General: In accordance with ASTM C 754, themanufacturer’s recommendations and National GypsumCompany “Gypsum Construction Guide.”

RECOMMENDATIONS

1. FRAMINGAlign floor and ceiling tracks to ensure plumb partition.

Secure track with suitable fasteners at a maximum of 24"o.c. Position studs in track on 16" or 24" centers byrotating into place for a friction fit. Steel studs shall beinstalled with all flanges pointed in the same direction.Secure studs located adjacent to door and window frames,partition intersections and corners with 3/8" Pan HeadType S Screws driven through both flanges of studs andtracks or by using a stud clincher.

2. SINGLE LAYER OR FIRST PLYCut gypsum board to allow for a 1/8" to 1/4" gap between

gypsum board and floor to prevent potential wicking.Apply gypsum board with the length parallel or at right angles

to the studs. Center abutting ends or edges over the studflanges.

For metal framing, screws shall be Type S, of a length toprovide not less than 3/8" penetration into framing andshall be spaced 24" o.c. max. If no adhesive is used,standard fastener spacings shall prevail.

For non-fire-rated construction, locate all attaching screws12" o.c. when framing is 24" o.c. and 16" o.c. whenframing is 16" o.c. or less. For fire-rated construction,vertical application, space screws 12" o.c. in the field and8" o.c. along the vertical abutting edges unless otherwisespecified. Attach the gypsum board to Steel Studs withType S Drywall Screws using an electric, drywallscrewdriver with a #2 Phillips bit. For vertical gypsumboard application with studs 24" o.c., erect the gypsumboard on one side of the partition, screw attaching to openend of stud flange first at vertical gypsum board joints.Complete the gypsum board application to the entire sideof the partition in this manner. For the opposite side, cutthe first gypsum board 2' wide so that joints will bestaggered. Fasten this and succeeding gypsum boards to allstuds on this side. When partition face is complete, returnto the first side and complete screw attachment of gypsumboard to all intermediate studs.

Make door and window framing openings of such size thatwhen the gypsum board is secured to the studs, it will fitsnugly into the steel frames.

3. FACE LAYERMechanical attachment of face layer for fire or sound rated

constructions shall be made in accordance with thespecifications for the system selected. When the face ply isattached with mechanical fasteners and with no adhesivebetween plies, the maximum spacing and minimumpenetration recommended for screws should be the sameas for single ply application.

Page 42: Ngc Gyp Wall Board

98 NATIONAL GYPSUM BOARD PRODUCTS

FLUSH-TO-WALL ATTACHMENTS

GYPSUM BOARD FASTENERS

STEEL ANGLEOUTSTANDING LEG1" WIDE MAX.

SHELF BRACKET SHELF BRACKETBETWEEN STUDS

GYPSUM BOARD

SHELFBRACKET

STEEL STUD

2 1/2" #14 WOOD SCREWS

MIN. 12" LONGWOOD FILLERBLOCK CUT FORSNUG FIT INSIDESTUD

4" MIN.

GYPSUM BOARD

SEE CHART BELOWFOR SHELF BRACKETALLOWABLE LOADS

SHELF BRACKET BEARING (1" MIN. BRACKET WIDTH)

STEELSTUD

1 1/2" #10 WOOD SCREWS

6" MIN.

1" X 3" X 12" WOOD BLOCKS LAMINATE ORSCREW ATTACHED TO BACK OF GYPSUMBOARD BETWEEN STUDS

SHELFBRACKETBEARING (1" MIN.BRACKETWIDTH)

EXTRA HEAVY LOADS

2 LAYERS 5/8" GYPSUM BOARD BOTH SIDES (SCREWS 12" O.C. BOTH SIDES)

1/4" DIA. BOLT NUT& WASHER

0.12 L MIN.

S-12 SCREWS. 16" O.C.

L (PARTITIONHEIGHTS)

3 5/8" STEEL STUDS. 24" O.C.

16 GAUGE STEEL STUD OR UCHANNEL TO FLOOR

0.12 L MIN.

ALLOWABLE LOAD 700 ft. lbs. per bracket.

GYPSUM BOARD FASTENERS

Allowable LoadType 1/2" (12.7 mm) 5/8" (15.9 mm)Fastener Size Gypsum Board Gypsum Board

Hollow 1/8" (3.2 mm) dia. SHORT 50 lbs.(23 kg) —Wall 3/16" (4.8 mm) dia. SHORT 65 lbs.(29 kg) —Screw 1/4" (6.4 mm), 5/16" (7.9 mm) 65 lbs.(29 kg) —Anchors 3/8" (9.4 mm) dia. SHORT — 90 lbs.(41 kg)

3/16" (4.8 mm) dia. LONG — 95 lbs.(43 kg)1/4" (6.4 mm), 5/16" (7.9 mm), 3/8" (9.4 mm) dia. LONG

Common 1/8" (3.2 mm) dia. 30 lbs.(14 kg) 90 lbs.(41 kg)Toggle 3/16" (4.76 mm) dia. 60 lbs.(27 kg) 120 lbs.(54 kg)Bolts 1/4" (6.4 mm), 5/16" (7.9 mm), 80 lbs.(36 kg) 120 lbs.(54 kg)

3/8" (9.4 mm) dia.

SHELF BRACKET

Allowable Load

Wood Block 80 ft. lbs. per bracket (108 N-M) – 2' o.c. (610 mm) 40 ft. lbs. per bracket (54 N-M) – 4' o.c. (1219 mm)

Without filler blocks using 50 ft. lbs. per bracket (68 N-M) – 2' o.c. (610 mm)min. #10 sheet metal screws 25 ft. lbs. per bracket (34 N-M) – 4' o.c. (1219 mm)into screw stud

SHELF BRACKET BETWEEN STUDS

Allowable Load With Wood Blocks

Wood Block with 1/2" (12.7 mm) gypsum board 40 ft. lbs. per bracket (54 N-M)Wood Block with 5/8" (15.9 mm) gypsum board 70 ft. lbs. per bracket (95 N-M)

Allowable Load With Sheet Metal (.0239)

.0239 sheet metal substituted 40 ft. lbs. per bracket (54 N-M)for wood with 1/2" (12.7 mm) gypsum board

.0239 sheet metal substituted 50 ft. lbs. per bracket (68 N-M)for wood with 5/8" (15.9 mm) gypsum board

HOLLOW WALL SCREW ANCHOR

COMMON TOGGLE BOLT

INSTALLATION

6" MIN.

Page 43: Ngc Gyp Wall Board

99NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGCSteel Frame Ceilings/Furring Channels or Studs

6" MIN.

TIE WIRES

4 PAN HEAD SCREWSEACH SIDE

16" LENGTHOF TRACK

FURRING CHANNEL SPLICE JOINT

SPLICE JOINT FOR STUDS

DESCRIPTION DETAILS

SPECIFICATIONS

RECOMMENDATIONS

See CSI Metal FramingSpecifications on page 97.

There are three types of steelfurring members for thescrew attachment ofgypsum board ceilings.

1. Furring Channels2. Resilient Furring Channels3. Steel StudsAll three are suitable for

fastening to the lowerchord of steel joists or tocarrying channels insuspended ceilingconstructions. FurringChannels are secured withclips or tie wires. ResilientFurring Channels shall besecured with wire ties. SteelStuds shall be attachedwith tie wires as shown onpage 99. Gold BondGypsum Board shall beapplied using gypsumdrywall screws spaced notgreater than 12" o.c.

RECOMMENDATIONSThese furring systems, when

employed with normalsteel joist construction andgypsum board, constitutenon-combustibleconstruction and, inaddition, fire resistanceratings are achieved asindicated on page 25.

LIMITATIONSLighting and other fixtures

shall be supported byframing; do not use gypsumboard to support them.

For large expanses of theseceiling systems withperimeter relief, controljoints must be located amaximum of 50' o.c. ineither direction; withoutperimeter relief, 30' o.c.maximum in eitherdirection.

DIRECT ATTACHMENT1. Space and position furring

channels in accordancewith manufacturerrecommendation. Wire tieResilient Furring Channels,Steel Studs or FurringChannels as shown onpage 100.

2. Apply gypsum board withits long dimension at rightangles to the channels.Locate gypsum board buttjoints over the center of thefurring channels. Attachgypsum board with 1" self-drilling drywall screws 12"o.c. located not less than3/8" nor more than 1/2"from edges.

SUSPENDED1. Install 1 1/2" channels 4'

o.c. with No. 8 ga. hangerwire spaced a maximum of4' o.c. along carryingchannels. Attach FurringChannels spaced not morethan 24" o.c. perpendicularto 1 1/2" C.R. Channelswith double strand ofsaddle tied No. 16 ga.galvanized tie wire, or 11/2" Furring Channel Clips.

2. Apply gypsum board withits long dimension at rightangles to the FurringChannels. Locate gypsumboard butt joints over thecenter of Furring Channels.Attach gypsum board with1" self-drilling drywallscrews 12" o.c. in the fieldof the board 8" or 12" o.c.at butt joints, located notless than 3/8" or more than1/2" from edges.

Page 44: Ngc Gyp Wall Board

100 NATIONAL GYPSUM BOARD PRODUCTS

INSTALLATION

FURRINGCHANNEL

TIE WIRE

HANGER SPACING4'0" C-TO-C MAX 1 1/2" CHANNELS

4'0" C-TO-C MAX

FURRING CHANNEL

GYPSUM BOARDMAX FURRING CHANNELSPACING 24" C-TO-C

HANGER WIRE, FURRING CHANNEL CLIP, OR WIRE TIE

1 1/2" CHANNEL PEICE 16"LONG-NESTED (TWO WIRETIES EACH SIDE)

1 1/2" CHANNEL

FURRING CHANNEL

KAL-KORE OR GYPSUMBOARD

KAL-KORE OR GYPSUMBOARD

FURRING CHANNEL CLIP OR WIRE TIE

3" MAX

VINYL“E-Z STRIP”

JOINT

HANGER WIRE

LOOSE WIRE TIES

SHORT PIECE OF FURRING CHANNEL

INVERTED FOR SPLICE1 1/2" CHANNEL

FURRINGCHANNEL

VINYL “E-Z STRIP” JOINTVENEER PLASTER OR JOINT

COMPOUND

VENEER PLASTER OR JOINTCOMPOUND

SADDLE TIE WITH DOUBLE STRANDNO. 16 GA. GALV. TIE WIRE

STEEL STUD

BAR JOIST

SHORT LENGTHOF TRACK

GYPSUM BOARD(FASTEN WITH TYPE SDRYWALL SCREWS 12" O.C. MAX.)

FURRING CHANNELS

FURRING CHANNEL DETAILS

CONTROL JOINT PARALLEL TO FURRING CHANNELS

CONTROL JOINT PERPENDICULAR TO FURRING CHANNELS

FURRING CHANNEL

MAIN RUNNER

SADDLE TIE

STEEL STUDS IN CEILING SYSTEM

RESILIENT FURRINGCHANNEL

Page 45: Ngc Gyp Wall Board

101NATIONAL GYPSUM BOARD PRODUCTS

09

29

00

09 29 00/NGCWood Frame Walls and Ceilings/Single Layer Construction

DESCRIPTION

STANDARD APPLICATIONStandard application (single

nailing) Regular Gold BondGypsum Board is usuallyapplied directly to woodframing members. Ceilingsare applied first, thensidewalls. Boards should beaccurately cut and jointsabutted but not forcedtogether. Horizontalapplication, long edges atright angles to nailingmembers, is preferred for itminimizes joints andstrengthens the wall orceiling. Nails shall bespaced not to exceed 7" onceilings, or 8" on sidewalls,a minimum of 3/8" and amaximum of 1/2" fromedges and ends of gypsumboard. Gypsum board nailsor annular ring nails, suchas the GWB-54 illustratedabove, are recommended.For a description of thevarious types of Gold BondGypsum Boards, refer topages 58 through 89.

DOUBLE NAILINGDouble nailing is an alternate

method of attachmentdevised to minimize nail-pops. This system requiresdoubling up on the fieldnails. The total quantity ofnails used does not double,however, since maximumnail spacing is increased to12" o.c. and conventionalnailing is used on theperimeter. Application isaccomplished by first singlenailing the field of theboard, starting at the centerand working toward endsand edges. Another nail isthen driven in closeproximity (2" to 2 1/2") toeach of the first nails. Thefirst series of nails are thenstruck again to ensure theboard is drawn tightly tothe nailing member.

FLOATING ANGLEMETHODFloating angle method of

gypsum board applicationeliminates the use of theperimeter nails at interiorcorners and where ceilingsand walls meet. Thismethod reduces the stressand strain on the board ifframing settles.Reference ASTM C 840,Section 9.

ADHESIVE NAIL-ONMETHODApply drywall adhesive to

face of studs or joists incontinuous beads.Reference ASTM C 840Section 10.

FIRE RESISTANCE RATINGSWhere fire ratings are

required, refer to pages 12, 13, 22, and 23. Forcomplete constructiondetails consult the specifictest report.

SCREW APPLICATIONScrew application is often

preferred as the screwholds the gypsum boardtight against the framingwhen applied asrecommended. Type W 1 1/4" Drywall Screws aredriven with an electricscrew gun equipped withadjustable screw depthcontrol and a #2 Phillipsbit. If framing is spaced upto 16" o.c., screws arespaced 12" o.c. max onceilings and 16" o.c. maxon walls. If framing isspaced 24" o.c., screwspacing must not exceed 12" o.c. Minimum screwpenetration shall be 5/8" forwood studs.

RECOMMENDATIONSCut gypsum board to allow for

a 1/8" to 1/4" gap betweengypsum board and floor toprevent potential wicking.

1/2" or 5/8" gypsum boardsingle layer application isrecommended for interiorfinishing of all buildingswith wood frameconstruction. The use of

5/8" gypsum board or 1/2"High Strength CeilingBoard on ceilings willminimize sagging. Duringcold weather the use ofpolyethylene film as aceiling vapor retarder is not recommended unlessceiling insulation isinstalled prior toapplication of gypsumboard.

LIMITATIONS1. 1/4" Gold Bond Gypsum

Board should be appliedonly to existing surfacesand should not be applieddirectly to framingmembers, except whenused with other thicknessesin double layer systemstested for specific purposes.Existing walls and ceilingsshould be sound, flat, leveland without void spaces.1/4" thick gypsum boardshould be applied with acombination of mechanicalfasteners, nails or screws,and adhesive that will bondto the substrate surfacecovering. Nails or screwsshould penetrate framingspaced not over 24" o.c.Adhesive should be appliedbetween framing membersto bond the gypsum boardto the substrate.

2. 3/8" Gold Bond GypsumBoard should not be usedon nailing members over16" o.c. When applied toceilings, the gypsum boardmust be applied with thepaper bound edges at rightangles to the nailing mem-bers and shall not be usedto support insulation. 1/2"or 5/8" Gypsum Boardshould not be used onnailing members over 24"o.c. When applied toceilings with the nailingmembers exceeding 16"o.c., the gypsum boardmust be applied with thepaper bound edges at rightangles to the nailingmembers.

3. If gypsum board ceilingboards are nailed to crossfurring, these membersshall have a minimumcross section of 2" x 2"(nominal) with same

spacing limitations asabove. With screws,nominal 1" x 2" furring maybe used. Spacing of theframing members toreceive furring must notexceed 24" o.c.

4. In single ply installation, allends and edges of gypsumboard should occur overframing members or othersolid backing except wheretreated joints occur at rightangles to framing or furringmembers.

5. Hold the gypsum boardfirmly against the framingwhile fastening with nailsor screws. Start at thecenter and work towardeach end and edge,spacing the fasteners asrecommended for eachtype of application.

6. Lighting and other fixturesshall be supported byframing; do not use gypsumboard to support them.

7. Gypsum board ceilings tobe decorated with water-thinned spray texture shallbe 1/2" or 5/8" thick andapplied perpendicular tothe framing. Framing shallnot exceed 16" o.c. for 1/2" regular gypsum board and24" o.c. for 1/2" HighStrength Ceiling Board and5/8" gypsum board.

8. Gypsum board ceilings toreceive a spray texturefinish must be primed witha sealing latex primer andallowed to dry beforespraying. This is tominimize sagging of thegypsum board anddiscoloration problems.

The use of water-based spraytextures may cause un-primed gypsum board tosag when any one or moreof the following conditionsexist:

1. Unventilated buildings.2. Use of vapor retarders

under certain conditions.3. Periods of prolonged high

humidity due to eitherweather conditions orclosed building units (poordrying conditions).

4. Inadequate framing support(can occur where framingchanges direction).

5. Improper type or thicknessof gypsum board.

Page 46: Ngc Gyp Wall Board

102 NATIONAL GYPSUM BOARD PRODUCTS

INSTALLATION

RECOMMENDATIONS

FLOATING ANGLESNo nails in shaded area.

SCREW APPLICATIONFast, positive, fewer heads to treat.

ADHESIVE/NAIL-ONIdeal for prefinished boards.

DOUBLE NAILINGMinimizes nail-pop.

SINGLE LAYER GYPSUMBOARD APPLICATION (alsoBase Layer of Double Layer)1. NAILSNails shall be GWB-54 or

cooler type located 3/8"min. to 1/2" max. fromedges and ends of board.Nails shall be a max. of 7"o.c. on ceilings and a max.of 8" o.c. on walls, exceptfor “Double Nailing”Procedure.

2. SCREWSDrywall screws for attaching

gypsum board to woodframing shall be 1 1/4",

Type W spaced not toexceed 12" o.c. on ceilings,16" o.c. on sidewalls wherestuds are 16" o.c. and 12"o.c. on sidewalls wherestuds are spaced 24" o.c.Screws for attachinggypsum board to gypsumboard shall be Type Gspaced as required.

3. STAPLESBase layer gypsum board may

be applied with power-driven staples spaced 7"o.c. on ceilings; 8" o.c. onsidewalls. Staples shall beU.S. Standard 16 gaugegalvanized wire staples

with 7/16" wide crownwith legs having divergentpoints. Legs shall be notless than 1" long for 3/8"base board, 1 1/8" long for1/2" base board or 1 1/4"long for 5/8" base board.

4. CORNERBEADSCornerbead shall be nailed

with gypsum board nailsspaced no greater than 9"apart on each flange of thebead with the nailsopposite. In lieu of nailing,cornerbead may be crimpapplied 6" o.c. with aspecial tool.

5. ADHESIVE APPLICATIONTO FRAMING

A. Apply gypsum boardadhesive to the woodframing with a caulkinggun.

FLOATING INTERIORANGLES To minimize fastener popping

in areas adjacent to walland ceiling intersections,the floating angle methodshould be used for eithersingle or double layerapplication of gypsumboard to wood framing.This method is applicablewhere single nailing,double nailing or screwattachment is used.Gypsum board should beapplied to ceiling first.

REPAIRING NAIL-POPS Nail-pops are caused by

lumber shrinkage afterboard application; loosegypsum board; improperlyaligned, twisted or bowedframing; or impropernailing.

Pops appearing before/duringdecoration should berepaired immediately.Those which occur afterone or more month’sheating are usually causedby lumber shrinkage andshould not be repaired untilafter heating season. Torepair, renail about 1 1/2"from the popped nail alongthe framing while applyingsufficient pressure adjacentto the nail to bring board infirm contact with theframing. If the popped nail

was improperly driven,remove it. If properlydriven, reseat just belowthe board face. Removeany loose material overreseated nail before treat-ing nail heads with jointcompound andredecorating.

ADHESIVE NAIL-ONAPPLICATIONThe adhesive nail-on system

for application of gypsumboard to wood framingmembers strengthens thewall and minimizes thepossibility of nail-popping.It reduces the number ofnails in the field, providesfor intimate contact and acontinuous bond betweenthe gypsum board andwood framing. All surfacesthat come in contact withthe adhesive should be dry,free of dirt, grease, oil orother foreign materials.

SCREW APPLICATIONDrywall screws attach gypsum

board to wood or steelframing or to other gypsumboards. They pull the boardtightly to the supports,minimizing surface defectsdue to loose boards. Whenproperly driven, they makea uniform depression freeof ragged edges and fuzz.

Page 47: Ngc Gyp Wall Board

09

29

00

103NATIONAL GYPSUM BOARD PRODUCTS

09 29 00/NGC

TECHNICAL DATA

FASTENER SELECTOR FOR WOOD FRAMING

Nail Type Length Gypsum Board Type Thickness

GWB-54 [Annular Ring 1/4" 1 1/4" (31.8 mm) Regular or Foil-back 3/8" (9.4 mm), (6.4 mm) head, 098 Dia. shank] 1 3/8" (34.9 mm) gypsum board. 1/2" (12.7 mm)

Gypsum Board Nail (Coated Nail length should Regular, Foil-back or Fire-Shield 1/4" (6.4), 3/8" (9.4 mm)cooler, flat head, diamond point) be sufficient (type X) gypsum board. 1/2" (12.7 mm),

for 7/8" (22.2 mm) penetration 5/8" (15.9 mm),into the framing member. 1" (25.4 mm)

Where a certain degree of fire resistance is required for gypsum board assemblies and construction, nails of sameor larger length, shank diameter, and head bearing area as those described in the fire test report must be used.

Screws Type W 1 1/4" (31.8 mm) Regular or Foil-back. 3/8" (9.4 mm), 1/2" (12.7 mm),5/8" (15.9 mm)

Staples US Std. 16 gauge 1" long (25.4 mm) Only in first 3/8" (9.4 mm)7/16" (11.1) crown with 1 1/8" (28.6 mm) layer of multi- 1/2" (12.7 mm)divergent points 1 1/4" (31.8 mm) layer application. 5/8" (15.9 mm)

PLATE

JOISTCEILING DETAIL

STUD

OUTSIDE CORNER

CORNERBEADPLATE

INSIDE CORNERPLATE

DETAILS

SPECIFICATIONS

See CSI 3-Part format Generic/Proprietary Specifications on page120.

Maximum Framing SpacingFor Single-Layer Gypsum Board

Gypsum Board Gypsum Board MaximumThickness Orientation Framing Spacing

to Framing

Ceilings:3/8" (9.5 mm)A PerpendicularB 16" (406 mm) o.c.1/2" (12.7 mm) ParallelB 16" (406 mm) o.c.1/2" (12.7 mm) PerpendicularB 24" (610 mm) o.c.5/8" (15.9 mm) Parallel 16" (406 mm) o.c.5/8" (15.9 mm) Perpendicular 24" (610 mm) o.c.

Walls:

3/8" (9.5 mm) Perpendicular 16" (406 mm) o.c.or Parallel

1/2" (12.7 mm) Perpendicular 24" (610 mm) o.c.or Parallel

5/8" (15.9 mm) Perpendicular 24" (610 mm) o.c.or Parallel

A Shall not support thermal insulationB On ceilings to receive hand or spray-applied water-based

texture material either 1/2" (12.7 mm) gypsum ceilingboard (ASTM C 1396/C 1396M) shall be appliedperpendicular to framing; other gypsum board products shall be applied perpendicular to framing and board thickness shall be increased from 3/8" (9.5 mm) to 1/2" (12.7 mm) for 16" (406 mm) o.c. framing and from 1/2" (12.7 mm) to 5/8" (15.9 mm) for 24" (610 mm) o.c. framing.

Page 48: Ngc Gyp Wall Board

104 NATIONAL GYPSUM BOARD PRODUCTS

The Gold Bond double layersystem consists of a facelayer of gypsum board job-laminated to a base layer ofgypsum board, or gypsumsound deadening boardapplied with power drivenscrews or staples, or nailedto the framing in theconventional manner.

DETAILS

SPECIFICATIONS

Wood Frame Walls and Ceilings/Double Layer Construction

DESCRIPTION

See CSI 3-Part formatGeneric/ProprietarySpecifications on page 120.

PLATE

JOISTCEILING DETAIL

STUD

OUTSIDE CORNER

CORNERBEAD PLATE

INSIDE CORNERPLATE

RECOMMENDATIONS

INSTALLATION

DOUBLE LAYER GYPSUM BOARD1. Base layerThe first layer may be

specified the same as singlelayer application exceptthat fasteners shall bedriven flush with the boardsurface and joints will notbe treated. Base layer mustnot be secured to framingwith clips.

2. Adhesive Application ofFace Layer, General

a. All joints shall fall at least10" from parallel joints inthe base layer. Adhesiveshall be: (select one)

b. ProForm all-purpose readymix joint compound or Sta-Smooth setting typecompound applied with anotched spreader to theback side of the finishlayer.

c. Adhesive is applied with acaulking gun. Align boardedges. Reference ASTM C 840, section 9.

3. Adhesive Application,Regular Gypsum Board

The finish layer shall bepositioned on the wall orceiling within 10 minutes(unless otherwise specifiedabove) and held in placewith sufficient temporary(nails) (Type G DrywallScrews) (bracing) to ensureadequate contact andalignment of the gypsumboards. When the bond has developed (usually 24 hours) the temporary(fasteners) (bracing) shall beremoved. Resulting holesshall be filled flush to thesurface with JointCompound and the jointsshall be finished.Cornerbead shall beapplied at all exteriorangles.

4. Adhesive Application,Prefinished Gypsum Board

a. Pre-bow board by storingovernight in such a positionthat the ends of each boardcurve away from the baselayer when put in verticalmounting position.

b. Apply ready-mix or Sta-Smooth joint compound innominal 5" ribbons of four1/4" x 1/4" beads locatedaround the perimeter andcenter of the boards(approximate coverage forready-mix is 9-10 gal./1000sq.ft and Sta-Smooth is 50-60 lbs./1000 sq.ft.). Analternative is 2" diameterdaubs 1/2" thick, 16" o.c.(approximate coverage forready-mix is 5 1/2"-6gal./1000 sq.ft. and Sta-Smooth is 30 - 35 lbs./1000sq.ft.).

c. Temporarily brace, asrequired, to ensure propercontact and edge alignmentof boards.

5. Mechanical Application ofFace Layer

Mechanical attachment offace layer for fire or soundrated constructions shall bemade in accordance withthe specifications for thesystem selected.

For non-rated construction,nails used in wood framingto supplement adhesiveshall be type GWB, of alength to provide 7/8"minimum penetration intoframing and shall bespaced 16" o.c. max.Screws used in woodframing shall be Type W, ofa length to provideminimum 5/8" penetrationinto the framing and shallbe spaced 24" o.c. max. If no adhesive is used,standard fastener spacingsshall prevail.

Cut gypsum board to allow fora 1/8" to 1/4" gap betweengypsum board and floor toprevent potential wicking.

In double layer constructionuse any of the followingappropriate laminatingadhesives: (1) Sta-SmoothCompound or Sta-SmoothLite for fast hardening; (2) All-Purpose JointCompound for spreadingon the back surface of thefinish layer boards: (3)drywall adhesive meetingASTM C 557.

Base layer is applied onceilings, then sidewalls,secured with 1 1/4" TypeW Screws 12" o.c. onceilings, 16" o.c. on walls;nails located 7" o.c. onceilings; 8" o.c. onsidewalls; staples 5" o.c. onceilings and 6" o.c. onsidewalls.

Finish layer is temporarilynailed or braced untiladhesive dries. On walls,prefinished boards, appliedvertically, can be pre-bowed, nailed just top andbottom.

RECOMMENDATIONS1. Double layer gypsum board

application over woodframing is recommendedfor the ultimate in wallsurfacing and in areaswhere increased fireprotection and better soundinsulation are desiredbetween rooms. (For testresults see pages 13-14 ofthis guide.) Custom builthomes, commercialbuildings and party wallsbetween apartments wouldbe considered appropriateareas for double layerapplication.

Page 49: Ngc Gyp Wall Board

105NATIONAL GYPSUM BOARD PRODUCTS

09 29 00/NGC

2. Laminating is an excellentway to apply Durasan, thevinyl-surfaced gypsumboard. This methodeliminates any visible attachment.

3. Sta-Smooth Compound or Sta-Smooth Lite is recommended for laminating as well as forjoint treatment where fasthardening is required.

LIMITATIONS 1. Joints of succeeding layers

must not fall at the samelocation. For greateststrength, it is recom-mended that the boards ofeach layer be staggered sothat joints of each layer areat least 10" apart.

2. During cold weather, maintain a room temperature of not lessthan 40˚F during mechanical attachment ofgypsum board, andbetween 50˚F and 70˚F for 48 hours before lamination, joint treatment,texturing and decoration,and continuously thereafteruntil completely dry.

CEILING JOISTS

BASE LAYERGYPSUM BOARD

LAMINATINGADHESIVE

2 X 4 WOODFRAMING

WOOD

BASE PROFORM JOINT TREATMENT(ALL JOINTS AND CORNERS)

SOUND TRANSMISSION CLASS 45 FIRE RESISTANCE RATING 1 HR.

CAULKING

JOINT COMPOUND

4D NAILS 12" O.C.2 X 4 PLATE

2 X 4, 16" O.C.

1/4" GYPSUM BOARD

1/2" FIRE-SHIELD C GYPSUM BOARD 2 LAYERS 5/8" FIRE-SHIELD GYPSUM BOARD

CAULKING

3 1/2" MINERAL WOOLOR GLASS FIBER

SOUND TRANSMISSION CLASS 58 FIRE RESISTANCE RATING 2 HRS.

FINISH LAYER TAPERED EDGEGYPSUM BOARD

09

29

00

Page 50: Ngc Gyp Wall Board

106 NATIONAL GYPSUM BOARD PRODUCTS

Resilient Furring Channel Construction

DESCRIPTION

SPECIFICATIONS

See CSI 3-Part format Generic/Proprietary Specifications on page 120.

DETAIL

5/8" FIRE-SHIELD GYPSUM BOARD

2 X 4 STUD

3 1/2" MINERAL WOOL ORGLASS FIBER FOR STC 50

1/2" RESILIENT FURRING CHANNEL

5/8" FIRE-SHIELD GYPSUM BOARD

TYPICAL SECTION

Resilient Furring Channels arefabricated of galvanizedsteel with expanded metallegs that provide resiliencyto reduce soundtransmission through woodframed wall and ceilingassemblies.

STANDARD APPLICATIONResilient Channels have

punched holes spaced 1"o.c. in the leg flanges tofacilitate fastening toframing members spacedeither 16" or 24" o.c. The12' long channels areapplied perpendicular tothe framing members andspaced not more than 24"o.c. Gypsum board is thenattached to the ResilientChannels with powerdriven, Type S DrywallScrews spaced 12" o.c.

RECOMMENDATIONS1. Construction, as shown in the

detail below, is recommend-ed to achieve sound and fire-rating as shown on pages11-26.

2. A 3" wide strip of 1/2" thickgypsum board should beused at the floor line toassure a solid base forattaching the gypsum boardand the base. An additionalstrip of gypsum board or aResilient Furring Channelshould be used at theceiling line.

3. The point of intersectionbetween the wall and floorshall be caulked prior toapplication of baseboard toobtain the best soundisolation.

4. On wood studs fastenchannel through alternateflanges at each stud using 1 1/4" GWB-54 Nails orType W Drywall Screws.Fasten both flanges atchannel ends.

5. Resilient Furring Channelsshould be fastened to woodjoists with one Type WDrywall Screw at each joistin alternate flanges.Channel ends may fall onor between joists but mustbe fastened to prevent anysliding movement whichcould create squeakingnoises. When channel endsfall between joists, overlapapproximately 1 1/2" andscrew-attach through bothlegs into a wood block heldabove the channels, oroverlap approximately 6"and fasten both channelsnear ends with 3/8" Type SPan Head Screws.

LIMITATIONS1. Spacing of Resilient Furring

Channels should notexceed 24" o.c. nor spanmore than 24".

2. Use only 1/2" or 5/8"gypsum board with thissystem.

RECOMMENDATIONS

INSTALLATION (RESILIENTFURRING CHANNELS ONONE SIDE OF PARTITION)Wood framing shall be

erected in accordance withconventional procedure,studs (16" o.c.) (24" o.c.). A1/2" x 3" shim strip ofgypsum board shall benailed to the base platecontinuously on theresilient side of thepartition. An additionalstrip of gypsum board or aResilient Furring Channelshould be used at theceiling line. ResilientFurring Channels shall belocated horizontally, 24"o.c. max., and be securedthrough alternating flangesat each stud with 1 1/4"GWB-54 Nails or Type WDrywall Screws. Abuttingchannel ends shall belocated over studs, shall begapped and shall befastened through bothflanges.

INSTALLATION (RESILIENTFURRING CHANNELS ONCEILINGS)Wood framing shall be

erected in accordance withconventional procedure,joists (16" o.c.) (24" o.c.)Resilient Furring Channelsshall be installedperpendicular to joists,spaced 24" o.c. and amaximum of 6" from theceiling-wall line with TypeW Screws through alternateflanges at each joist.

Where channel ends overlapat a joist, Type W DrywallScrews must be driventhrough both channelsthrough both flanges intojoist.

Where channel ends overlapbetween joists, woodblocking may be used totake Type W DrywallScrews driven through bothchannels through bothflanges, or Type S PanHead Screws may be usedto fasten channel endstogether.

APPLICATION OF GYPSUMBOARDAttach gypsum board to

Resilient Furring Channelswith 1" Type S DrywallScrews 12" o.c. and toframing through filler stripswith drywall screws 12"o.c. that penetrate framing5/8" minimum.

Note: Screws used to attachgypsum board to resilientfurring channels shall notcontact wood framing.

Page 51: Ngc Gyp Wall Board

09

29

00

107NATIONAL GYPSUM BOARD PRODUCTS

09 29 00/NGC

INSTALLATION

SPLICE ON JOIST1 1/4" Type W Screws

SPLICE BETWEEN JOISTS3/8" Type S Pan Head Screws

SPLICE BETWEEN JOISTS, ALT.1 1/4" Type W Screws

NOM. 1 X 4 BLOCK

6"

2 x 4 PLATE

2 x 4 STUDS

3 1/2" MINERALWOOL OR

GLASS FIBER

2 x 4 PLATE

DRYWALL SCREWS1" DRYWALL SCREWS

TAPE JOINTTREATMENT

3" x 1/2" THICK STRIPGYPSUM BOARD FILLER

RESILIENTFURRING CHANNEL

24" O.C.

Page 52: Ngc Gyp Wall Board

108 NATIONAL GYPSUM BOARD PRODUCTS

Gypsum Board Over Masonry

DESCRIPTION

DETAILS

SPECIFICATIONS

Z FURRING

1 1/4"

3/4"

1", 11/2", 2"

See CSI 3-Part format Generic/Proprietary Specifications on page 120.

A. Z FURRING CHANNEL 1. Application of Foam.

Z Furring Channel is usedto secure rigid insulationand gypsum board tomasonry walls. Insulationthickness (1", 1 1/2", 2")determines depth of Zfurring web. The channel isapplied vertically andfastened to the masonrywall through the short (3/4")flange with suitablemasonry fasteners 24" o.c.maximum. Application isprogressive. After fasteningeach Z Furring Channel, a24" wide floor-to-ceiling-high insulation board is fitbetween the wall and thewide (1 1/4") flange.

2. Application of GypsumBoard. Erect Gold BondGypsum Board eithervertically or horizontally tothe Z Furring Channels.Gypsum board edges orends that run parallel to thechannels shall be centeredand abutted over channels.Fasten gypsum board with1" Type S Drywall Screwsspaced 12" o.c. Whengypsum board erection iscomplete, finish all jointsand screw heads inaccordance with ProFormJoint Finishing System.Prefinished gypsum boardmay be laminated verticallyto the channels with screwsat top and bottom.

Limitations Power driven fasteners should

be used to secure furringonly when wall ismonolithic concrete.Regular concrete nails canbe used for fastening to unitmasonry. If block is old,test nailing should be donein advance to determineoptimum size and type of nail.

B. LAMINATION 1. Application of Foam.

Insulation may be urethanefoam or extrudedpolystyrene. Expandedbead polystyrene is notrecommended. Forhorizontal gypsum board

application, install woodfurring strips (nominal 2"wide x 1/32" greater thanthe foam thickness)horizontally along the wall-ceiling and wall-floorangles, where horizontalgypsum board joints willfall, and around door andwindow openings. Forvertical gypsum boardapplication, furring stripsare required at thehorizontal wall-ceiling andwall-floor lines and arounddoor and windowopenings.

Masonry surface must be dry,clean and free of dust, dirt,form release agents, oil,grease or water solublematerials. Treat paintedmasonry as recommendedfor laminating to paintedsurfaces. Apply adhesive tothe foam insulation in 3/8"dia. beads continuouslyaround the perimeter andthrough the field in the longdirection with the beadsspaced 16" o.c. Contactadhesive manufacturer forcompatibility with foam.

Apply the foam boardshorizontally to the wallwith a sliding motion andhand press entire board toensure full contact ofadhesive and wall surface.

2. Application of GypsumBoard. ProForm All-Purpose Joint Compoundsmay be used. (Do not usewater base compounds forlaminating prefinishedboards to foam.)

Permanent nails or screws 12" o.c. are required tofasten gypsum board towood furring. Gypsumboard must be installed aminimum of 1/8" from thefloor. Use temporary nailsor bracing as necessary tohold gypsum board boardsin firm contact to the foamuntil adhesive has dried orset.

Limitations 1. Nails or screws used for

attachment of gypsumboard to furring strips mustnot penetrate through thefurring.

2. Power driven fastenersshould be used to securefurring to monolithicconcrete. Regular concretenails can be used forfastening to unit masonry. Ifblock is old, test nailingshould be done in advanceto determine optimum sizeand type of nail.

3. During cold weather, roomtemperature between 50˚Fand 70˚F must bemaintained uniformlyduring application anduntil adhesive is thoroughlydry or premises areoccupied. Provideadequate ventilation.

4. Gypsum board is notrecommended in areaswhere it will be exposed toexcessive moisture orcontinued high humidity.

5. Since the use of foamplastic insulation isregulated by many buildingcodes, consultation withlocal building authorities isrecommended beforeinstallation.

Since unprotected foaminsulation may represent afire hazard, it should becovered promptly andcompletely with gypsumboard.

Page 53: Ngc Gyp Wall Board

09

29

00

109NATIONAL GYPSUM BOARD PRODUCTS

09 29 00/NGC

RECOMMENDATIONS

INSTALLATION

Z FURRING CHANNEL HORIZONTAL INSTALLATION WITH DRYWALL ADHESIVE

DAUB METHOD USING JOINT COMPOUND

Z FURRING1. Begin application of

Z furring members bypositioning first piecevertically at a corner.Locate the piece on thewall adjacent to the wallbeing insulated first.

2. Insulation thicknessdetermines distance of Z furring web from wallbeing insulated. At theappropriate distance, andwith wide flange pointingtoward applicator, secure Z furring with appropriatefasteners through shortflange. (Note to Specifier:Power driven fasteners arenot recommended for usewith masonry block.)

3. Install 24" wide floor-to-ceiling insulation board,pressed snugly against webof first Z. Install next Z withwide flange overlappingedge of first insulationboard. Fasten to wallthrough narrow flange.

4. Continue in this manner,with Z furring 24" o.c. toend of wall. Locate last Zso that web is located adistance equal to insulationthickness from adjoiningwall. Cut last insulationboard to fit remainingspace.

5. At exterior corner, attachthe Z through its wideflange, with narrow flangeextending beyond thecorner. Begin with anarrow strip of floor-to-ceiling insulation, widerthan insulation thicknessbut not exceeding 3".Continue application offurring and insulationprogressively as describedabove.

6. At windows, doors and trimareas, use wood nailers(nom. 2" wide x insulationthickness plus 1/32"). Usethe nailers also at wall-floorangles to support trim andprovide backing for base.

7. Apply gypsum board with1" Type S Screws throughflanges of Z furring, 12" o.c.

LAMINATION1. Masonry or monolithic

concrete shall be abovegrade, dry, free of dust,loose particles, oil, greaseor other foreign material.

2. Joint compound used asadhesive shall be mixed toa consistency thick enoughto allow a 2" daub to stickto the underside of a broadknife held parallel to thefloor.

3. Apply 2" to 2 1/2" diameterdaubs of adhesive 1/2"thick, 16" o.c. in bothdirections to the masonrywall. The adhesive layoutmust provide for a row ofdaubs located a maximumof 2" from board ends, andcare must be exercised tocenter daubs on verticaljoints. No more adhesiveshall be applied to the wallthan will be covered withboard in 15 minutes.Approximate coverage forjoint compound (powder)used as an adhesive is 30-35 lbs./1000 sq. ft.

4. Cut gypsum board to allowfor 1/8" to 1/4" clearancebetween board and floor toprevent potential wicking.

5. Install gypsum board byhand pressing each boardtight to the wall makingcertain that all daubs are inpositive contact with theboard.

6. Support boards at eachcorner to keep them fromslipping to the floor by useof a concrete nail driventhrough a small block ofnominal 1" lumber.

7. Butt boards to eachpreviously positionedboard to ensure flush joints.

8. If necessary to hold boardsstraight, plumb and inproper alignment, drivemasonry nails throughsmall wood blocks and intomasonry at high pointsonly. After adhesive is dry(24 - 48 hours) removetemporary nails.

9. Fill all holes and treat jointswith tape and jointcompound.

Page 54: Ngc Gyp Wall Board

110 NATIONAL GYPSUM BOARD PRODUCTS

DESCRIPTION

Solid Laminated Partitions

DETAILS

TECHNICAL DATA

Maximum Partition LengthCeiling Height Between Restraints

12' (3658 mm) 14' (4267 mm)11' (3353 mm) 20' (6096 mm)10' (3048 mm) Over 20' (6096 mm)

GYPSUM BOARD

BASE

L FLOORRUNNER

FLOOR LINE

VERTICAL SECTION USINGMETAL FLOOR RUNNER

09250TScale: 3" = 1'-0"

1" FIRE-SHIELD SHAFTLINER

JOINTCOMPOUND

ADHESIVE

1" FIRE-SHIELD SHAFTLINER

GYPSUM BOARD CORNERBEAD

12d NAIL/12" O.C.

TAPE AND JOINTCOMPOUND

1" FIRE-SHIELD SHAFTLINER

GYPSUM BOARD

CORNER WALL DETAIL09250U

Scale: 3" = 1'-0"

CAULKING

L RUNNER

CASING BEAD

ANCHORAGE TO CONCRETECEILINGS, WALLS OR COLUMNS

09250VScale: 3" = 1'-0"

1/4"

1" FIRE-SHIELD SHAFTLINER

Laminated Partitions havebeen developed for usewhere sturdy, nonload-bearing walls are desired.The total thickness isnominal 2". 1" Fire-ShieldShaftliner is used betweenface layers of gypsumboard.

PHYSICAL PROPERTIES A. Fire Resistance. Fire

endurance ratings havebeen established by thefollowing tests:FM WP 671 - 1 HOUR:1/2" Regular Gypsum faceboards and ProForm BrandSta-Smooth jointcompound* as laminatingcompound.UL U505 - 2 HOUR:5/8" Type X Fire-Shieldface boards and ProFormBrand Sta-Smooth jointcompound* as laminatingcompound.UL U525 - 2 HOUR:1/2" Fire-Shield Type Cface board and ProFormBrand Sta-Smoothcompound* as laminatingcompound.UL U529 - 2 HOUR:1/2" Fire-Shield Type Cface boards and ProFormBrand Sta-Smooth jointcompound* as laminatingcompound.

B. Sound Isolation. An STCrating of 34 has beenachieved in tests con-ducted in accordance with ASTM E 90.

C. Economical. The laminatedpartition offers a substantialsaving in installation timeand subsequently in laborcosts over other types ofsolid partitions. The 1"gypsum core is quickly andeasily installed and thelarge sheets of gypsumboard provide a dry finishsurface in minimum time.

LIMITATIONS The laminated partition is

adapted to any type ofbuilding for nonload-bearing partitions notexceeding 12' in height.Further limitations to heightare based on the partitionlength in the table below.

*Required for fire rating.

Page 55: Ngc Gyp Wall Board

09

29

00

111NATIONAL GYPSUM BOARD PRODUCTS

09 29 00/NGC

SPECIFICATIONS

See CSI 3-Part format Generic/Proprietary Specifications on page 120.

GYPSUM BOARD

WOOD CASING

STOP

DOOR

JOINT COMPOUND ADHESIVE

1" FIRE-SHIELD SHAFTLINER

WOOD JAMB DETAIL09250W

Scale: 3" = 1'-0"

GYPSUM BOARD

CLIPS NAILED TO SHAFTLINER(4d nails bent over)

JAMB DETAIL09250X

Scale: 3" = 1'-0"

STRAP AND ANCHORCLIP ASSEMBLY

STEEL JAMB1. Secure floor runner to floor

with approved fasteners 24"o.c. Ceiling runner shall besecured in an appropriatemanner to the ceilingconstruction. The L runnershall be used as both floorand ceiling runners in Fire-Rated construction.

2. The 1" Fire-ShieldShaftliner, cut 1/4" shorterthan wall height, shall beinstalled vertically and shallbe fastened to the floor andceiling runners with two 1 5/8" Type S DrywallScrews, each located 2"from each edge of theShaftliner boards.

3. Sta-Smooth Compoundshall be applied evenlywith a notched spreader(with 1/4" x 1/4" notches, 1 1/2" o.c.) to the back sideof the 4' wide, ceilingheight gypsum board faceboards. Install the boardsvertically to both sides ofthe Shaftliner. Stagger

RECOMMENDATIONS

board joints 12" from theShaftliner joints and 24"from joints on each side ofthe wall.

Face boards are then screwed,12" o.c. to the top andbottom runners with 1 7/8"Type S screws and aresecured to the Shaftlinerwith 1 5/8" Type S DrywallScrews spaced 24" o.c.horizontally and verticallyto include screws along the vertical edges of eachboard.

Gypsum board joints shall bereinforced with paper tapeand finished with jointcompound.

4. Door frames shall bevertical, plumb and true,and shall be securelyanchored to floor andceilings as shown on the plans.

5. Completed partition shall be straight and plumb.