172
PART D CATALOGUE D Sales 1300 NHP NHP | nhp.com.au Industrial Electrical and Automation Products, Systems and Solutions AUTOMATION PRODUCTS SOFT STARTERS & DRIVES AUTOMATION PRODUCTS SAFETY PLCs Safety, Interlock, Limit & Trip-Wire Switches Switch Mode Power Supplies Industrial Limit & Foot Operated Switches Visualisation & Reporting Software Non-contact Safety Switches Operator Panels & Touch Screens Safety Controllers Fieldbus I/O Systems Emergency stop trip-wire switches Soft Starters Variable Speed Drives 01 02 03

Upload: truongtuong

Post on 02-Jan-2017

434 views

Category:

Documents


33 download

TRANSCRIPT

PART D CATALOGUE

D

Sales 1300 NHP NHP | nhp.com.au

Industrial Electrical and Automation Products, Systems and Solutions

AUTOMATION PRODUCTS

SOFT STARTERS & DRIVES

AUTOMATION PRODUCTS

SAFETY

PLCs

Safety, Interlock, Limit & Trip-Wire Switches

Switch Mode Power Supplies

Industrial Limit & Foot Operated Switches

Visualisation & Reporting Software

Non-contact Safety Switches

Operator Panels & Touch Screens

Safety Controllers

Fieldbus I/O Systems

Emergency stop trip-wire switches

Soft Starters

Variable Speed Drives

01

02

03

2

NHP Electrical Engineering Products

(NHP) specialises in motor control, power

distribution and automation systems.

NHP offers the Australasian market

the complete industrial electrical

and automation solutions package.

As authorised distributors for Rockwell

Automation and their Allen-Bradley®

products in our designated areas of

Australia and throughout all of New

Zealand, NHP is partnered with the leading

global provider of industrial automation

solutions and switchgear components.

An Australian owned company, NHP is

committed to serving the Australasian

industry with quality products and

customer support. This is achieved through

a 1000+ strong team which is distributed

across 25 branches and 24 regional

locations throughout Australia and New

Zealand.

While NHP stock an impressive 45,000+

line items, we are much more than a

component supplier. NHP source the

highest quality products from leading

global suppliers, and customise these into

solutions for the local Australian and New

Zealand markets, providing a complete fit to

purpose systems and solutions service.

At NHP we have a strong customer focus

and we look to provide the right product

and product solutions for our customers’

requirements and applications, all at a

competitive price. We value and care for our

customers and support them by offering

personalised service and assistance to

meet their every need and demand. Our

customers can have 100% confidence in our

ability to support them when, where and

how it is needed.

Put simply, NHP is ‘easy to do business with’.

NHP Electrical Engineering Products

NHP NATIONAL MANUFACTURING AND DISTRIBUTION CENTRE

Please scan the QR code to view our corporate presentation.

Scan the QR code for career opportunities at NHP

SCALE

KNOWLEDGE

AGILITY

PARTNERSHIPS

“Corporate DNA” The NHP Value Proposition

Qu

ick Re

fere

nce

Ind

ex

2

3

1

AUTOMATION PRODUCTS

PLCs

Fieldbus I/O Systems

Operator Panels and Touch Screens

Visualisation and Reporting Software

Switch Mode Power Supplies

SAFETY

Safety, Interlock, Limit and Trip-Wire Switches

Safety Controllers

Industrial Limit Switches

Foot Operated Switches

SOFT STARTERS & DRIVES

Soft Starters

Variable Speed Drives

This catalogue is segregated into sections. The first page of each

section has its own contents page for easier product selection.

Each page has a bold section number for prompt page location.

Each page is identified by both its section number and its page

number eg. 2-8 signifies this is section 2 page 8.

Three indexes in each catalogue make finding products easy;

A product listing is situated at the front of this catalogue.

A complete section contents listing is situated at the front of the

catalogue.

An alphanumeric index is situated at the rear of this catalogue.

All catalogue numbers are bold and shaded.

For pricing refer to the relevant price list, e.g. to find prices for parts

in the Part D Catalogue, refer to the Part D Price List.

Parts that are available on indent only or parts that are assembled

to order will be identified in the relevant price list.

Please make sure you have the most current price list for each

catalogue. Contact your NHP Sales Representative or refer to

www.nhp.com.au to obtain a copy of the most current price list.

Current NHP standard conditions of sale apply to this price list

catalogue.

Exp

lanatio

n o

f Term

s

TYPICAL PAGE LAYOUT

EXPLANATION OF TERMS AND HEADINGS USED WITHIN THIS CATALOGUE

2 - 8

2

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘B2’

Emergency stop trip-wire switch “kits”

Notes: 1) Items included in all of the above kits

1 x Tension spring (As per requirement AS 1755-2000) 1 x 55164, turnbuckle 4 x 55151, thimble 8 x 55152, wire clamps _ x Cable (quantity as above) _ x 55150, wire support (quantity as above) Wire supports are based upon supporting the trip-wire at 2.5 - 3 metre intervals.

TQZS-75...

TQZS-73...

TQZS-71...

TQZS-80

TQZS-70

Series TQ ZS: Trip-wire switchesEmergency stop for conveyor and various other industries

TQZS70...8 metresSlim housing

Price $Cat. No

TQZS70KIT10M 383.88

Trip-wireSwitch

TQZS70... kit

TQZS70101SVD

Items included in kit 1)Trip-wire length

8 metres

1 x TQZSTS150N

8 x TQZSWR5MM (cable)

3 x 55150 (wire support)

TQZS71...5-20 metresSmall housing

TQZS71KIT20M 581.00

TQZS71... kit

TQZS71101 20 metres

1 x TQZSTS250N

20 x 55153P (cable)

5 x 55150 (wire support)

TQZS73...30-50 metresGeneral purpose

TQZS73KIT50M 1006.38

TQZS73... kit

TQZS3101SWVD 50 metres

1 x TQZSTS250N (spring)

50 x 55153P (cable)

10 x 55150 (wire support)

TQZS-75...30-50 metresLarge housing

TQZS75KIT50M 1130.88

TQZS75... kit

TQZS75101SWVD 50 metres

1 x TQZSTS250N (spring)

50 x 55153P (cable)

10 x 55150 (wire support)

TQZS80...10-50 metresWith emergency stop and flag indicator

TQZS80KIT50M 975.25

TQZS80... kit

TQZS80202SWVD 50 metres

1 x TQZSTS250N (spring)

50 x 55153P (cable)

10 x 55150 (wire support)

Section number

Illustrative photographs or diagrams indicative of products available (not necessarily to scale)

Price Schedule(s) listed for products on this page.

Description of product, ratings etc.

Section and page number e.g. section 2, page 8

Additional information, accessories, technical data, notes, etc.

Footnotes, as necessary, are referenced to the bottom of each page. E.g. 2)

Cat. No. of product is always next to the applicable price.

The catalogue numbers are shaded for quick identification.

Page contents

14

Pro

du

ct Listin

g

Product Sub Product Section Page

EEmergency stop

trip-wire switches

Heavy-duty limit switches: 77 HL and 77 TL series 2 19Installation instructions 2 17Spare parts and accessories 2 15Type NTW cast aluminium 2 13

FFieldbus I/O

systems for

industrial

automation

applications

750 Series 1 21750 Series Intrinsically safe system 1 28750 Series PROFIsafe system 1 29750 Series Starter kits 1 34750 Series Vibration monitoring 1 28751 Series AS-i Fieldbus system 1 30753 Series Quick connect 1 35

857 Series JUMPFLEX Transducers 1 26Overview 1 16Programming and diagnostic software 1 31

Fieldbus I/O

systems for long

distance, lighting

and irrigation

control systems

Ordering details 1 42

Overview 1 38

LLimit switches Light duty 6 A: ES/EM 95 series 2 11

Medium duty 10 A: PS21 series 2 11Medium duty 10 A: PS31 series 2 12Medium Duty 6 A:ES/EM 41 series 2 12

Introduction to CA 8 2.2 - 5.5 kW compact contactor system 1 4Mounting rail - to suit DIN style equipment 1 37Safety contactors CAS - AC and DC operated 4 - 500 kW 1 18

MMicro

Programmable

Logic Controllers

Hitachi EH Micro series 1 6

Mitsubishi Alpha 2 series 1 2

Modular

Programmable

Logic Controllers

Hitachi EH-150 series 1 10

Micro and modular PLC accessory selection guide 1 15

NNon-contact

Safety switches

Belt drift switches 2 10

Emergency stop trip-wire switch kits 2 8Emergency stop trip-wire switches 2 9Series BZ16 2 7Series HSSi4 2 7Series RC Si - 56 2 6Series RC Si - M30 2 6

OOperator panels

and touch

screens

Communications cables 1 54Dimensions and cut-outs 1 56Graphics operator panels 1 51Graphics touch screens 1 52Overview 1 49SC 207 1 48Text based operator panels 1 50VTWIN Configuration software 1 55

SSafety Controllers Foot operated switches 2 22

Limit switches - pull-wire (non safety) 2 21Pressure switches 2 23Series MF1: Standstill monitor 2 20Series NSC: Fail safe control unit 2 20Series SRM: Fail safe control unit 2 20

Pro

du

ct Listin

g

Product Sub Product Section Page

Safety interlock

switches

Series AZM 415: Heavy duty Solenoid 2 5Series ES - 13SB: Light duty hinged 2 4Series ES - 95: General purpose 2 2Series ES - 95: General purpose flap/hinge 2 4

Series ES - 95: General purpose rotary cam 2 4Series ST - 14: Light duty 2 2Series ST - 61: Heavy Duty 2 3Series STM 295: Medium duty solenoid 2 5

Soft starters CSX and CSXi - introduction, specifications and ordering details 3 7Electronic soft starters product selection guide 3 2EMX3 - introduction, specifications and ordering details 3 12PCS - introduction, specifications and ordering details 3 4

Switch mode

power suppliesSwitch mode power supplies 1 68

VVariable Speed

Drives

Brake resistor selection by duty cycle 3 37Brake resistors and accessories - ordering details 3 38Input and output choke - ordering details 3 35

Product selection guide 3 23

Rating and selection chart 3 40

Santerno SINUS Nano range - introduction, standard specifications and ordering details 3 24Semiconductor fuses and accessories - ordering details 3 36SINUS Micro range - introduction, standard specifications and ordering details 3 25SINUS Nano and Micro ranges - options 3 26SINUS Penta - multi-pump application and 3 46SINUS Penta - options 3 48

SINUS Penta - range and selection (380 - 415 V) 3 32

SINUS Penta - range and selection (660 - 690 V) 3 44

SINUS Penta - specifications 3 49

SINUS Penta range - introduction, standard specifications and options 3 27

Visualisation

and reporting

software

Ordering details 1 66

Overview - World class 32-bit SCADA/HMI software 1 59

NHP’s Values

To achieve our vision, NHP has six values

which define how we operate

Energy

An energetic “can and will do” attitude and approach. Enthusiasm is infectious and we look to provide this in all aspects of our business and our customers’ business.

Consistency

We provide our customers with what they want, when, where and how they want it, for today, tomorrow and into the future.

Passion for Customers

Without customers we have no business, so we are passionate about everything we do for them. We service our customers’ needs 24 hours a day, 7 days a week, 365 days a year.

Integrity

We do what is right for our customers, our staff, our industry and our community.

Adaptiveness to Change

If we don’t adapt, we wither then die. While we have adhered to the same values and service objectives since day one, we also have adapted to the changing face of our industry and the industrial world, and we look to help our customers prosper as a result.

Commitment to Performance

We aim to provide products and solutions on time, in full, every time. Our customers can expect to receive service above their expectations in everything we do.

Australia and New Zealand Manufacturing and Distribution Centre

NHP prides itself on being able to provide customers with tailored solutions that suit their individual needs. Whilst we have significant stockholdings and expertise at all our locations throughout Australia and New Zealand, the purpose of our National Manufacturing and Distribution Centre in Laverton, Melbourne is to develop these solutions through manufacturing, assembly, servicing and design and engineering.

SIZE

Warehouse 7,000 m2 Manufacturing 5,000 m2

STAFF 270+ Employees

OPERATING HOURS

6.00am - 11.30pm, Monday-Friday

STOCKHOLDING

- 45,000+ line items (20,000 stocked)

- Approximately $70 M

ITEM THROUGHPUT

- Approximately 5,500 per day (6,000 lines throughout Australasia)

FACTS

3.00 pm are despatched the same day.

95 % customer service based on an ‘on time in full, first time’ measurement.

AUSTRALIA AND NEW ZEALAND MANUFACTURING AND DISTRIBUTION CENTRE

Laverton Facility Tour Booklet2011

Scan the QR code to view the Laverton Tour brochure.

Scan the QR code to view our Concept Express video

ONE OF NHP’S ELECTRIC CARS ON DISPLAY AT THE

SUSTAINABILITY CENTRE IN LAVERTON, MELBOURNE

Sustainability Centre

Emerging technology supporting sustainability

A major push towards more sustainable

practices by many in the industrial

electrical industry is now clear for all to

see in today’s environment.

Learning to use energy smarter to

reduce our consumption and increase

one’s bottom line is now a key

consideration in all applications.

A major focus at NHP is to provide

sustainable solutions for our

customers as well as throughout our

own operations. Early in 2010 we

designed and constructed our very

own Sustainability Centre - located at

our existing National Manufacturing

and Distribution Centre in Laverton,

Melbourne.

The Centre utilises cutting edge

technology and houses equipment

which enables us to conduct research

& development, test new products and

look closely at ways we can effectively

introduce and manage sustainable

practices.

The centre is driven by power

generated from Solar Panels and

houses an interactive display allowing

visitors a close-up view of a range of

sustainable energy technologies which

currently include:

A horizontal axis wind generator

Solar photo-voltaic systems

Grid interactive systems

Off-grid hybrid systems

Dual axis solar tracker, and

Energy Management & control

systems

NHP are also proud participants in

the Victorian Government’s electric

vehicle trial. The trial will provide NHP

with valuable insights to assist in future

business planning, as well as help

the wider community understand

the process, timelines and barriers

for transitioning to electric vehicle

technologies in the future.

NHP’s Sustainability Centre and

participation in the electric vehicle

trial highlight our commitment to

encourage sustainable practices across

all facets of the workplace.

Our aim is to remain at the forefront

of the industry, as leaders in providing

alternative energy solutions for

commercial and industrial applications.

NHP also works closely with Melbourne

University, RMIT University and Victoria

University, providing course advice

and industry based supervision of

undergraduate and postgraduate

students.

NHP is proud to educate young

electrical engineers in this growing,

and important industry sector.

Scan the QR code to Book a Live Tour.

Scan the QR code to view a video on our electric car trial.

Scan the QR

To assist customers in finding what they want, we have classified

our extensive product range into the following categories.

Our vast automation product

range can provide a completely

integrated automation solution,

for both the factory and process

automation industries, that can

be delivered with our Integrated

Architecture platform.

Controllers

Relays

Drives

Screens

Communications

Products and Brands

AUTOMATION SYSTEMSMOTOR CONTROL& DRIVES

NHP offers conventional motor

starting and protection products as

well as advanced electronic starting,

controlling and protection products

to suit fractional horsepower motors

through to large frame main drive

systems. NHP also offers customised

motor starters across the entire

range.

POWER DISTRIBUTION & PROTECTION

NHP provides Australasia’s

widest range of low voltage

power distribution and

protection products supplied

as components or as part of a

manufactured solution. Circuit

protection against current

overloads up to 6300A is available

together with a wide range

of surge and arc protection,

switching products and power

supplies.

ERICO

WOHNER

SELCO

ampcom

GHISALBA

MICROELETTRICA

POWER QUALITY

NHP’s Power Quality products

and systems provide solutions

for power factor correction and

harmonic mitigation. To meet

specific customer requirements,

this group of products are

generally customised at our

manufacturing centre in

Laverton, Victoria.

Systems

Regulators

ELECTRONICONBELUK

COSMOTEC

STEGO

IBOCO

ENCLOSURES & CLIMATE CONTROL

NHP has a complete range of mild

steel, stainless and plastic enclosure

options in a variety of IP ratings and

configurations including modular

switchboard systems.

To complement NHP’s enclosure

systems, a wide range of climate

control solutions are also available.

BOCCHIOTTI

ERICO

TERMINATION & WIRING SYSTEMS

NHP has a wide range of screw

and screw-less terminals, terminal

accessories (such a DIN rail and

jumper pins) and cable ducting.

Products and Brands (cont’d)

NHP offers a range of control

relays and timers that can be

used in conjunction with a

conventional automation system

to switch higher loads or in

stand alone applications where

the only basic single function

control is required.

TIMERS &

CONTROL RELAYS

With an extensive range of

audible and visual signalling

devices, NHP provides solutions

for hundreds of applications,

be it general safety warning,

process control, fire or

evacuation.

SIGNALLING DEVICES

GRASSLIN

The automation system relies

on information from the field

to control the process. NHP’s

switching and sensing suite of

products cover all field sensing

requirements including standard

and hazardous area applications.

FIELD SWITCHING & SENSING

Most processes, even if

automated, still require some

manual control and NHP

provides a complete range of

control products and systems for

this purpose.

ELEKTRA

SPOHN + BURKHARDT

TER

OPERATOR

CONTROL DEVICESR

PLUGS & SOCKETS

Divided into two distinct

product ranges, NHP’s plugs

and sockets provide solutions

for a wide range of applications

and are available in a wide

range of amperages and pin

configurations.

sockets

PROCONECT

NHP offer a large variety of

quality safety products that

meet international standards,

with products ranging from

simple emergency stop switches

to safety monitoring relays.

SAFETY PRODUCTS

STEUTE

Products and Brands (cont’d)

NHP provided a world class

range of hazardous area

equipment for explosive

environments including light

fittings, enclosures and terminal

boxes, control stations and

intrinsically safe automation

products.

HAZARDOUS AREA EQUIPMENT

WAGO

STEUTE

Energy Metering is the essential

component to understanding

your energy consumption

and power quality. NHP has

a complete range of energy

meters and power quality

analysers to meet the most

demanding of applications.

METERING

NHP offers a large selection

of products and solutions

tailored towards renewable

energy applications including

Solar and Wind. From high DC

rated protection and switching

devices, solar panel control and

monitoring products through to

a range of inverters and power

factor correction systems.

and Control Boxes

RENEWABLE ENERGY PRODUCTS

NHP has a wide range of services including

technical support, field service and maintenance

contracts, repair services and training.

These services are delivered by NHP qualified

technicians and our supply partners.

SERVICES & TRAININGSERVICES & TRAINING

Products and Brands (cont’d)

WAGO

STEUTE

STEUTE

KATKO

HAZARDOUS AREA EQUIPMENT SAFETY PROCESS CONTROL

2. Application Classes

When servicing important industries

such as the oil and gas, petrochemical

and grain handling there is no room for

complacency. At NHP our aim is to provide

a world class range of hazardous area

equipment for the hazardous market which

includes light fittings, terminal boxes,

control stations and an extensive suite of

automation products. NHP has been in

this field for many years and has acquired

a comprehensive knowledge on explosion

protection products, so wherever explosive

atmospheres are prevalent, NHP can

provide the safest solution.

For any industrial application, the safety

of employees and the general population

is of major importance. NHP has a long

history in the safety industry and can be

a trusted destination for all your safety

application needs. NHP offer a large

variety of quality products that meet all

relevant international standards, with

products ranging from simple emergency

stop switches, to light curtains, safety

monitoring relays all the way up to fully

integrated safety PLC systems. Our product

range extends further into SIL3 rated Safety

Critical Shutdown systems.

and Control Systems

Like the principles which drive the

process industry, NHP is committed to

delivering products of continuous quality

to assist our customers in achieving

process optimisation. Encompassing

a wide range of industries including

oil refining, petrochemicals, water and

sewage treatment, food processing, and

pharmaceuticals, the NHP process control

product portfolio offers complete system

integration.

With first-hand experience and capabilities,

and a solid understanding of the intensive

continuous nature of Process operations,

NHP reduces the risk associated with

continuously achieving the business

value promised by these technologies. In

addition NHP continues to leverage from

International relationships with recognised

process control companies and experts,

giving NHP access to a knowledge base

which has consistently demonstrated its

ability to deliver product quality, service

and application knowledge.

ENERGY MANAGEMENT SUSTAINABILITY

3. Application Solutions

NHP can provide Energy Management

Metering and Software solutions that

monitor and record energy information

so operators can identify consumption

trends and take corrective actions. Real-

time measurements of these electrical

parameters, such as voltage variations or

distortions, may have alarm thresholds

set to warn managers if preset limits are

reached. These real-time measurements

also allow site managers to anticipate

overload conditions that could, for

example, trip a circuit breaker. NHP can

provide a wide range of products to

complement any Energy Management

Solution.

With an increasing focus on the state of

global warming and the requirement to

decrease our carbon footprint, the use

of sustainability is becoming a popular

phenomenon. Our partnerships with

many of the industries best suppliers

from around the world means that NHP

offer a large selection of products and

solutions tailored towards renewable

energy applications including Solar and

Wind. From high DC rated protection and

switching devices, solar panel control and

monitoring products through to a range of

inverters and power factor correction, NHP

has an extensive offering.

and Control Boxes

1

Automation products, PLCs, I/O systems,

operator panels and touch screens, SCADA software

MICRO PROGRAMMABLE LOGIC CONTROLLERSMitsubishi Alpha 2 series ................................................................................................................1 - 2

Hitachi EH Micro series ....................................................................................................................1 - 6

MODULAR PROGRAMMABLE LOGIC CONTROLLERSHitachi EH-150 series......................................................................................................................1 - 10

Micro and modular PLC accessory selection guide ...................................................1 - 15

FIELDBUS I/O SYSTEMS FOR INDUSTRIAL AUTOMATION

APPLICATIONSOverview ................................................................................................................................................1 - 16

750 Series ..............................................................................................................................................1 - 21

857 Series JUMPFLEX Transducers ........................................................................................1 - 26

750 Series Intrinsically safe system ........................................................................................1 - 28

750 Series PROFIsafe system .....................................................................................................1 - 29

750 Series Vibration monitoring .............................................................................................1 - 28

751 Series AS-i Fieldbus system ..............................................................................................1 - 30

Programming and diagnostic software .............................................................................1 - 31

750 Series Starter kits .....................................................................................................................1 - 34

753 Series Quick connect ............................................................................................................1 - 35

FIELDBUS I/O SYSTEMS FOR LONG DISTANCE, LIGHTING AND

IRRIGATION CONTROL SYSTEMSOverview ................................................................................................................................................1 - 38

Ordering details .................................................................................................................................1 - 42

OPERATOR PANELS AND TOUCH SCREENSSC 207 ......................................................................................................................................................1 - 48

Overview ................................................................................................................................................1 - 49

Text based operator panels .......................................................................................................1 - 50

Graphics operator panels ............................................................................................................1 - 51

Graphics touch screens ................................................................................................................1 - 52

Communications cables ..............................................................................................................1 - 54

VTWIN Configuration software ................................................................................................1 - 55

Dimensions and cut-outs ............................................................................................................1 - 56

VISUALISATION AND REPORTING SOFTWARE - ADROIT

Overview - World class 32-bit SCADA/HMI software ................................................1 - 59

Ordering details .................................................................................................................................1 - 66

Switch mode power supplies...................................................................................................1 - 68

2

Safety

SAFETY INTERLOCK SWITCHESSeries ST - 14: Light duty ................................................................................................................2 - 2

Series ES - 95: General purpose ..................................................................................................2 - 2

Series ST - 61: Heavy Duty .............................................................................................................2 - 3

Series ES - 95: General purpose rotary cam ........................................................................2 - 4

Series ES - 13SB: Light duty hinged .........................................................................................2 - 4

Series ES - 95: General purpose flap/hinge .........................................................................2 - 4

Series STM 295: Medium duty solenoid ................................................................................2 - 5

Series AZM 415: Heavy duty Solenoid ...................................................................................2 - 5

NON-CONTACT SAFETY SWITCHESSeries RC Si - M30 ................................................................................................................................2 - 6

Series RC Si - 56 ....................................................................................................................................2 - 6

Series HSSi4 .............................................................................................................................................2 - 7

Series BZ16 ..............................................................................................................................................2 - 7

Emergency stop trip-wire switch kits .....................................................................................2 - 8

Emergency stop trip-wire switches .........................................................................................2 - 9

Belt drift switches .............................................................................................................................2 - 10

LIMIT SWITCHESLight duty 6 A: ES/EM 95 series ...............................................................................................2 - 11

Medium duty 10 A: PS21 series ...............................................................................................2 - 11

Medium duty 10 A: PS31 series ...............................................................................................2 - 12

Medium Duty 6 A:ES/EM 41 series ........................................................................................2 - 12

EMERGENCY STOP TRIP-WIRE SWITCHESType NTW cast aluminium .........................................................................................................2 - 13

Spare parts and accessories .......................................................................................................2 - 15

Installation instructions ................................................................................................................2 - 17

Heavy-duty limit switches: 77 HL and 77 TL series .....................................................2 - 19

SAFETY CONTROLLERSSeries NSC: Fail safe control unit ............................................................................................2 - 20

Series MF1: Standstill monitor ..................................................................................................2 - 20

Series SRM: Fail safe control unit ............................................................................................2 - 20

Limit switches - pull-wire (non safety) ................................................................................2 - 21

Foot operated switches ...............................................................................................................2 - 22

Pressure switches .............................................................................................................................2 - 23

3

Soft starters and drivesElectronic soft starters product selection guide..............................................................3 - 2

S+SPCS - introduction, specifications and ordering details ..............................................3 - 4

AUCOM

CSX and CSXi - introduction, specifications and ordering details .......................3 - 7

EMX3 - introduction, specifications and ordering details ......................................3 - 12

VARIABLE SPEED DRIVESProduct selection guide ...............................................................................................................3 - 23

Santerno SINUS Nano range - introduction, standard specifications and ordering

details .......................................................................................................................................................3 - 24

SINUS Micro range - introduction, standard specifications and ordering details

3 - 25

SINUS Nano and Micro ranges - options ...........................................................................3 - 26

SINUS Penta range - introduction, standard specifications and options .....3 - 27

SINUS Penta - range and selection (380 - 415 V) .........................................................3 - 32

Input and output choke - ordering details ......................................................................3 - 35

Semiconductor fuses and accessories - ordering details .......................................3 - 36

Brake resistor selection by duty cycle .................................................................................3 - 37

Brake resistors and accessories - ordering details .......................................................3 - 38

Rating and selection chart..........................................................................................................3 - 40

SINUS Penta - range and selection (660 - 690 V) .........................................................3 - 44

SINUS Penta - multi-pump application and ....................................................................3 - 46

SINUS Penta - options ...................................................................................................................3 - 48

SINUS Penta - specifications ......................................................................................................3 - 49

Se

ctio

n C

on

ten

ts Listing

1 - 1

Automation products, PLCs, I/O systems, operator panels and touch screens, SCADA software

1

Micro Programmable Logic Controllers Mitsubishi Alpha 2 series 1 - 2Hitachi EH Micro series 1 - 6Modular Programmable Logic Controllers Hitachi EH-150 series 1 - 10Micro and modular PLC accessory selection guide 1 - 15Fieldbus I/O systems for industrial automation applications Overview 1 - 16750 Series 1 - 21857 Series JUMPFLEX Transducers 1 - 26750 Series Intrinsically safe system 1 - 28750 Series PROFIsafe system 1 - 29750 Series Vibration monitoring 1 - 30751 Series AS-i Fieldbus system 1 - 31Programming and diagnostic software 1 - 33750 Series Starter kits 1 - 34753 Series Quick connect 1 - 35Fieldbus I/O systems for long distance, lighting and irrigation control systems Overview 1 - 38Ordering details 1 - 42Operator panels and touch screens SC 207 1 - 48Overview 1 - 49Text based operator panels 1 - 50Graphics operator panels 1 - 51Graphics touch screens 1 - 52Communications cables 1 - 54VTWIN Configuration software 1 - 55Dimensions and cut-outs 1 - 56Visualisation and reporting software - Adroit Overview - World class 32-bit SCADA/HMI software 1 - 59Ordering details 1 - 66Switch mode power supplies 1 - 68

FFFFFFFFIIIIEEEEEEEEELLLLLDDDDDDDDDBBBBBBBUUUUUUUSSSSSSSSSSS STEMSIII///////////OOOOO SSSSYYYYYYYYYYYSSSSSSSSSTTTTTTTTTTTTTTEEEEEEMMMMMSSSSSSSSSSSSS

MMICCRRO PLCSMMICCRRO PLCS MODULAARR PPLLCCS

FFIELLDDBBUSS II//OO SSYYSSTTEEMMSS

OPEERRAATTOORR PPAANNEELLSS AANNDD TOUCHH SSCCRREEEENNSS

SWITCHH SSWW MMOODE POWER SUUPPPPLIES

1 - 2

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Easier programming

The graphical user interface of the AL-PCSWIN-E package makes programming the Alpha series very easy. On the left and right you have graphical representations of the inputs and outputs, with the pre-programmed function blocks between them (timers, counters, real-time clocks etc.). You just use the mouse to ‘draw’ graphical connections (circuits) between the inputs, function blocks and outputs to define the program logic. Using this simple approach you can create programs with up to 200 function blocks (Alpha 2), and each function block can be reused as many times as necessary within the same program. Program simulation

This feature is particularly useful, enabling you to simulate your program without an Alpha controller connected to your PC.The AL-PCSWIN-E simulation module displays a realistic representation of the controller program. You can activate inputs by clicking with the mouse and the status of the function blocks and program execution are then displayed graphically on your screen.Monitoring functions

The AL-PCSWIN-E “Monitor” function enables you to connect an Alpha controller to your computer and monitor actual program execution on your computer screen. In this mode the current status of the I/Os and function blocks are displayed on the screen during program execution.Process visualisation

AL-PCSWIN-E also comes with a simple process visualisation system called ‘System Sketch’. It is displayed in a separate window into which you can copy and configure graphical elements from your program (inputs, outputs, function blocks etc.) or from another Windows application. Once you have set up the System Sketch window you can use it to perform a graphical simulation and monitoring of your program without using the programming interface. Among other things this can make setting up, installing and maintaining your application much simpler.Modem communications

The Alpha is capable of connection to both GSM and land line modems. Through a GSM modem SMS text messages can be sent to multiple mobile phones from the Alpha whenever an event takes place that requires attention. SMS text messages can be sent to the Alpha from mobile phones to remotely control the outputs. Messages sent to the Alpha are accepted only from “known” mobile phone numbers and a return message is sent to confirm that the requested action has occurred.

Full-featured calendar and clockThe Alpha family has a calendar and clock function with automatic summer/winter time switching. Each Alpha2 controller program can process up to 1,200 clock/calendar-activated on/off switching commands.

Mitsubishi programmable logic controllerAlpha 2 series

OUT4OUT2 OUT3OUT1

AL2-10MR-D

OK

ESC

+

-

1 2 3 4 5 6DC INPUT

-+ (B)(A)

POWER24V DC

RELAY OUTPUT

8290

71.2

2- 4.2 Ø

RELAYOUTPUT

(B) 1 2 3 4 5 6 7 8DC INPUT

+

24V DC

OUT1 OUT2 OUT3 OUT4

OK

ESC

+

-

80M1 LISTEDIND. CONT.EQ.

MADE IN JAPANMITSUBISHI ELECTRIC CORPORATION L U

CU

SR

AL2-14MR-D

POWER

- (A)

OUT5 OUT6

124.6

90

112.6

82

2- 4.2 ØDimensions (mm)

14/24 I/O

10 I/O

All models are 52 mm deep.

Features

Compact and robust 100 V AC - 240 V AC or 24 V DC power supply 1500 bytes EEPROM memory standard Built-in Real Time Clock as standard Sourcing or sinking type DC inputs (on 24 V DC models only) 0-10 V analogue signal inputs (on 24 V DC models only) High current outputs On-device programming through keypad and LCD screen Windows based programming software, Visual Logic Easy access PC programming port

The simple, user friendly Mitsubishi series has been designed for use around your home, office, factory...anywhere that requires flexible programmable control. Every Alpha allows your to analyse inputs and set outputs according to your program. The Alpha displays that status of your inputs and outputs on a LCD screen for quick verification.

1 - 3

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Mitsubishi programmable logic controllerAlpha 2 series

The ALPHA 2 family - Defining a new class of performance

The new Alpha 2 family from Mitsubishi Electric defines a new class of performance for automation applications. With its outstanding capabilities the Alpha 2 family is set to dominate the class it has created.

The Alpha 2 will exceed your expectations in any task you set it and can process up to 200 function blocks in a single program, and every function (timers, counters, analogue signal processing, calendar, clock etc.) can be used as many times as you need in all your programs.

Designed to suit all applications

Public facilities - Airports, train stations, hospitals, road guidance

Building automation - Lighting, HVAC, shutters/gates, security

Commerce - Parking, stores, gas station, hotels golf courses

Home automation - ON/OFF of electrical products, life support for aged, security

Testing facilities - Testing and measuring equipment Exhibition stage effects - lighting, movement control Agriculture - Farms, green house, animal house,

temperature watering, feeding control Hobby - Model making, gardening, weekend carpenter Education - Educational materials in schools Factory Automation - Automation equipment, facility

retrofit, controls

1 - 4

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Accessories

Description Cat. No. Price $

Programming/Comms cable, PLC to PC, or PLC to L/line Modem (9 pin D)

USB to Serial converter (RS 232)

Alpha DVD which includes AL-PCSWINE programming software, manuals, sample code, laboratory notes and quick start guides

Transducer, PT100 RTD, 2 channel, 3-wire, -50 °C to +200 °C range

Transducer, Thermocouple, 2 channel, K-Type, -50 °C to +450 °C range

Memory Module, EEPROM to copy and transfer user memory

GSM Modem with antenna, 12 - 24 V DC

NEXTG Modem with antenna, 12 - 24 V DC

Modem cable, PLC to Modem, (9 pin D)

External Power supply 24 V DC, 3.5 A power supply

External Power supply 24 V DC, 5 A power supply

Mitsubishi programmable logic controllerAlpha 2 series

AL-210-MRA

AL-210-MRD

AL-214-MRA

AL-214-MRD

AL-224-MRA

AL-224-MRD

Base units

I/O counts

100 - 240 V AC

24 V DC

100 - 240 V AC

24 V DC

100 - 240 V AC

24 V DC

Cat. No. Price $Power Supply

6

8

15

100 - 240 V AC

6

8

15

24 V DC

(sink/souce)

10

14

24

4

4

6

6

9

9

Relays

6 1)

8 2)

8 2)

0-10 V DC

Digital Inputs Digital

Output

Analogue

Output

AL-232-CAB

USB-COM 3)

AL-DVD

AL2-2PT-ADP 4)

AL2-2TC-ADP 4)

AL2-EEPROM-2 5)

ALPHAGSMMODEM6)7)

ALPHANXGMODEM6)7)

AL2-GSM-CAB 6)

XCSL85C

XCSP120C

The ALPHA family delivers unbeatable features and performance:

• Operational in ambient conditions -25 °C to +55 °C

• Alarm messages and process data can be displayed

• Programming and variable adjustments can be made through the buttons and screen

• Capable of being used as an AS-I bus slave

• DC expansion input module can be used as a 1 KHz high speed counter

• DNV, CE, UL and cUL Certifications

• Graphical windows based software

Starter kits

Description Cat. No. Price $

AL2-14MRA + AL-232-CAB + USB-COM + AL-DVD

AL2-14MRD + AL-232-CAB + USB-COM + AL-DVD

AL2-24MRA + AL-232-CAB + USB-COM + AL-DVD

AL2-24MRD + AL-232-CAB + USB-COM + AL-DVD

AL2-14AC-KIT

AL2-14DC-KIT

AL2-24AC-KIT

AL2-24DC-KIT

Notes: 1) Inputs can either be digital or analogue. 2) The first 8 inputs can either be digital or analogue. 3) Required for programming when no serial port is available on the personal computer. 4) Temperature element is not included. Customer to supply. 5) Cannot be used with old Alpha series PLCs. 6) Not compatible with 10 I/O models. 7) Requires an AL2-GSM-CAB, a DC power supply and a customer supplied SIM card.

+ USB-COM + AL-DVD AL

Price Schedule ‘B3’

1 - 5

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Description Cat. No. Price $

4 Digital Input, 100-240 V AC

4 Digital Input, 24 V DC, NPN or PNP

4 Digital Output, Relay, 2 A

4 Digital Output, Transistor PNP only2 Analogue Output, 0-10 V DC, or 4-20 mA, Accuracy of +/- 1% full scale, resolution of 2.5 mV, or 8 mA, Load of 5K-1m, or up to 500 Ω

Mitsubishi programmable logic controllerAlpha 2 series

AL2-4EX-A2

AL2-4EX

AL2-4EYR

AL2-4EYT

AL2-2DA

Description Cat. No. Price $

4.5” STF 3 CLR high resolution 24 V DC + GT Designer3 software

HMI Programmable Cable

USB to serial converter (RS-232)

GT1030HBD2 1)

GT01-C30R2-6P 2)

USB-COM

Visualisation with Graphical Operating Terminal (GOT)

has never been easier

Price Schedule ‘B3’

Notes: 1) Additional GOT HMI are available. Please contact NHP. 2) Cable suitable for GT1020 and GT1030 HMI.

1 - 6

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Micro programmable logic

controllersEH Micro series

Base model options - 10/14/20/23/28/40/64 I/O

Expandable to 320 I/O with 4 x 64 I/O expansion units

Digital input options - 24 V DC, both PNP and NPN (universal)

Digital output options - relay, or 24 V DC NPN, PNP or SSR

Analogue resolution - 12 bit

Analogue in options - 0-20 mA/4-20 mA/0-10 V/-10 V to +10 V

Analogue output options - 0-20 mA, 4-20 mA, 0-10 V

Power supply options 100-240 V AC, or 24 V DC

CPU - 32-bit RISC, 10 microseconds/instruction

User Memory - 16 K steps 20/40/64 I/O, 3 K steps other

Data Memory - 32 K words 20/40/64 I/O, 4 K words other

Memory - Flash for User Memory, Battery for Data Memory

Self diagnosis - LED indication memory, prog, battery low

Programmable in Ladder, or IL - 101 instruction types

High speed counter - 1 phase, 100 kHz, 20/40/64 I/O bases

High speed counter - 2 phase, 60 kHz, 20/40/64 I/O bases

High speed counter - 1&2 phase, 10 kHz, 14/23/28 I/O base

PWM - 2 kHz total for 10/14/23/28 Transistor output models

24 V DC for ext. use, 14/20/23/28/40/64 I/O base models

Filtering delay - Adjustable 0 to 20 milliseconds - stop chatter

Removable terminals for easy installation and removal

Protective hinged terminal covers

Conformity to global standards - CE, UL, c-UL and C-Tick

RS 232 port, with selectable speed 4800 to 38400 bps.

RS 422/485 port for 23/28 base, optional 20/40/64 I/O base

Real time clock - 20/23/28/40/64 I/O base models

LED indication of digital input and output status

Relay contact life - 20 mill. mech, 200,000 elec @ 1.5 A

Program Run/Stop switch 14/20/23/28/40/64 I/O base models

RTD modules - Pt100, 2&3 wire, -100 to +600°C range

External pots to adjust internal variables 14/23/28 I/O

Pulse Train - 65 kHz, 20/40/64 I/O transistor output models

Pulse Train - 5 kHz total, 16 bits for 10/14/23/28 models

PWM - 65 kHz, 20/40/64 I/O transistor output models

Refer catalogue SI-E108U

Features

The EH-Micro series provides an economical, compact and yet powerful solution for your programmable logic control requirements. The base units of the EH-Micro series can either be used as a stand alone PLC, or most have the ability to connect to a much larger network. The base units can manage as few as 10 I/O, or as many as 320 I/O using the maximum of four expansion units. The range of features of the EH-Micro is extensive and the programming software is free for some of the smaller base units. (See below). Up to 32 individual EH-Micro base units can be networked to an Hitachi EH-150 PLC, or to a PC, or an IPC. The new EH-Micro web controller models, (Just like the EH-150 series) have the ability to act as a gateway from the Hitachi PLC ranges, through a LAN to a host PC, or IPC.

Free software - ACTWIN can be downloaded from the NHP website. This version of the ACTWIN software allows full programming capabilities for the 10, 14 and 28 I/O base units only. It will permit all other base units to be programmed, but with the following limitations.

• Program size max. 3 K steps • Ladder programming only • Analogue functions are not available • No expansion units are permitted

To download the software go to: http://www.nhp.com.au/orc Register yourself with NHP and you will be presented with the member homepage. Go to – Product Info and Tools> Automation and Communication> PLC> ACTWIN Download the zip file, extract the contents to a folder, run “install.exe” and follow the instructions. Select the “Hitachi EH-Nano” driver option during the program installation. If you have any difficulty with this process then contact the Automation and Process department – 03 9420 4501

The programming software required for the 23 I/O EH-Micro base units and for all base units using any of the expansion units must be either ACTWINH, or the more economical ACTWINM1. ACTWINH can be also used for the larger Hitachi PLC series, while ACTWINM1 is only for the EH-Micro series. All three versions of the software are nearly identical and so there is no need to learn to how to use a new software package when moving to another Hitachi PLC Hardware series. All three versions of the software use ladder logic and are compliant with IEC61131-3.

1 - 7

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Micro programmable logic

controllersEH Micro series – Ordering details

Price Schedule ‘B3’

Refer catalogue SI-E108U

10 I/O

14 I/O

20 I/O

23 I/O

28 I/O

40 I/O

64 I/O

Approvals

6 DI, 24 V DC / 4 DO, 24 V DC PNP Transistor / 24 V DC power supply

6 DI, 24 V DC / 4 DO, 24 V DC NPN Transistor / 24 V DC power supply

6 DI, 24 V DC / 4 DO, Relay, 2 ampere / 24 V DC power supply

8 DI, 24 V DC / 6 DO, 24 V DC PNP Transistor / 24 V DC power supply

8 DI, 24 V DC / 6 DO, 24 V DC NPN Transistor / 24 V DC power supply

8 DI, 24 V DC / 6 DO, 24 V DC PNP Transistor, Short Circuit Protected /

24 V DC power supply

8 DI, 24 V DC / 6 DO, Relay, 2 ampere / 24 V DC power supply

8 DI, 24 V DC / 6 DO, Relay, 2 ampere / 110-240 V AC power supply

8 DI, 110 V AC ONLY / 6 DO, 110-240 V AC SSR, 0.5 ampere /

110-240 V AC power supply

12 DI, 24 V DC / 8 DO, 24 V DC NPN Transistor / 24 V DC power supply

12 DI, 24 V DC / 8 DO, 24 V DC PNP Transistor, Short Circuit Protected /

24 V DC power supply

12 DI, 24 V DC / 8 DO, Relay, 2 ampere / 24 V DC power supply

12 DI, 24 V DC / 8 DO, Relay, 2 ampere / 110-240 V AC power supply

13 DI, 24 V DC, 2 AI, 0-10 V DC, or 0-20 mA / 9 DO, Relay, 2 ampere, 1 DO,

24 V DC PNP Transistor, 1 AO, 0-10 V DC, or 0-20 mA / 24 V DC power supply

13 DI, 24 V DC, 2 AI, 0-10 V DC, or 0-20 mA / 9 DO, Relay, 2 ampere, 1 DO, 24

V DC PNP Transistor, 1 AO, 0-10 V DC, or 0-20 mA / 110-240 V AC power supply

16 DI, 24 V DC / 12 DO, 24 V DC PNP Transistor / 24 V DC power supply

16 DI, 24 V DC / 12 DO, 24 V DC NPN Transistor / 24 V DC power supply

16 DI, 24 V DC / 12 DO, 24 V DC PNP Transistor, short circuit protection /

24 V DC power supply

16 DI, 24 V DC / 11 DO, Relay, 2 ampere, 1 DO 24 V DC PNP Transistor /

24 V DC PS

16 DI, 24 V DC / 11 DO, Relay, 2 ampere, 1 DO 24 V DC PNP Transistor / AC PS

16 DI, 24 V DC / 12 DO, Relay, 2 ampere / 24 V DC power supply

16 DI, 24 V DC / 12 DO, Relay, 2 ampere / 110-240 V AC power supply

16 DI, 110 V AC ONLY / 12 DO, 110-240 V AC SSR, 0.5 ampere /

110-240 V AC power supply

24 DI, 24 V DC / 16 DO, 24 V DC PNP Transistor, short circuit protection /

24 V DC power supply

24 DI, 24 V DC / 16 DO, 24 V DC NPN Transistor / 24 V DC power supply

24 DI, 24 V DC / 16 DO, Relay, 2 ampere / 24 V DC power supply

24 DI, 24 V DC / 16 DO, Relay, 2 ampere / 110-240 V AC power supply

40 DI, 24 V DC / 24 DO, 24 V DC PNP Transistor, short circuit protection /

24 V DC power supply

40 DI, 24 V DC / 24 DO, 24 V DC NPN Transistor / 24 V DC power supply

40 DI, 24 V DC / 24 DO, Relay, 2 ampere / 24 V DC power supply

40 DI, 24 V DC / 24 DO, Relay, 2 ampere / 110-240 V AC power supply

EH-D10DTP

EH-D10DTN

EH-D10DR

EH-D14DTP

EH-D14DTN

EH-D14DTPS

EH-D14DR

EH-A14DR

EH-A14AS

EH-D20DTN

EH-D20DTPS

EH-D20DR

EH-A20DR

EH-D23DRP

EH-A23DRP

EH-D28DTP

EH-D28DTN

EH-D28DTPS

EH-D28DRP

EH-A28DRP

EH-D28DR

EH-A28DR

EH-A28AS

EH-D40DTPS

EH-D40DTN

EH-D40DR

EH-A40DR

EH-D64DTPS

EH-D64DT

EH-D64DR

EH-A64DR

Base Units

Description Cat. No. Price $

1 - 8

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘B3’

Micro programmable logic controllersEH Micro series – Ordering details

Refer catalogue SI-E108U

Expansion Units - Digital

Description Cat. No. Price $

8 DI, 24 V DC / 24 V DC power supply

8 DO, 2 ampere / 24 V DC power supply

8 DO, 24 V DC PNP Transistor, Short Circuit Protected / 24 V DC power supply

8 DO, 24 V DC NPN Transistor / 24 V DC power supply

4 DI, 24 V DC / 4 DO, Relay, 2 ampere / 24 V DC power supply

4 DI, 24 V DC / 4 DO, 24 V DC PNP Transistor, Short Circuit Protected / 24 V DC power supply

4 DI, 24 V DC / 4 DO, 24 V DC NPN Transistor / 24 V DC power supply

8 DI / 6 DO, 24 V DC PNP Transistor / 24 V DC power supply

8 DI / 6 DO, 24 V DC PNP Transistor, Short Circuit Protected / 24 V DC power supply

8 DI / 6 DO, 24 V DC NPN Transistor / 24 V DC power supply

8 DI, DC / 6 DO, Relay, 2 ampere / 24 V DC power supply

8 DI, DC / 6 DO, Relay, 2 ampere / 110-240 V AC power supply

16 DI, 24 V DC / 24 V DC power supply

16 DO, Relay, 2 ampere / 24 V DC power supply

16 DO, 24 V DC PNP Transistor, Short Circuit Protected / 24 V DC power supply

16 DO, 24 V DC NPN Transistor / 24 V DC power supply

16 DI / 12 DO, 24 V DC PNP Transistor / 24 V DC power supply

16 DI / 12 DO, 24 V DC PNP Transistor, Short Circuit Protected / 24 V DC power supply

16 DI / 12 DO, 24 V DC NPN Transistor / 24 V DC power supply

16 DI / 12 DO, Relay, 2 ampere / 24 V DC power supply

16 DI / 12 DO, Relay, 2 ampere / 110-240 V AC power supply

40 DI, 24 V DC / 24 DO, 24 V DC NPN Transistor / 24 V DC power supply

40 DI, 24 V DC / 24 DO, 24 V DC NPN Transistor / 24 V DC power supply

40 DI, 24 V DC / 24 DO, relay 2 ampere / 24 V DC power supply

40 DI, 24 v DC / 24 DO, relay 2 ampere / 100 - 240 V AC power supply

Expansion Units - Analogue

4 AI, 0-10 V DC or -10 to +10 V DC or 0-20 mA or 4-20 mA / 2 AO, 0-10 V DC or 0-20 mA or 4-20 mA / 110-240 V AC power supply

4 AI, 0-10 V DC or -10 to +10 V DC or 0-20 mA or 4-20 mA / 2 AO, 0-10 V DC or 0-20 mA or 4-20 mA / 24 V DC power supply

4 RTD, PT100, 2 or 3 wire / 24 V DC power supply

4 RTD, PT100, 2 or 3 wire / 110-240 V AC power supply

4 RTD, PT100, 2 or 3 wire / 2 AO, 0-10 V DC or 0-20 mA or 4-20 mA / 24 V DC power supply

4 RTD, PT100, 2 or 3 wire / 2 AO, 0-10 V DC or 0-20 mA or 4-20 mA / 110-240 V AC power supply

2 AI, 0-10 V DC with RS232C port for 20, 40 and 64 I/O base units

2 AI, 0-10 V DC with RS485 port for 20, 40 and 64 I/O base units

Expansion Cables

Expansion cable, 100 cm long (included for free with all types of expansion modules)

Expansion cable, 500 cm long (vertical arrangement)

Expansion cable, 1000 cm long (remote arrangement)

EH-D8ED

EH-D8ER

EH-D8ETPS

EH-D8ETN

EH-D8EDR

EH-D8EDTPS

EH-D8EDTN

EH-D14EDTP

EH-D14EDTPS

EH-D14EDTN

EH-D14EDR

EH-A14EDR

EH-D16ED

EH-D16ER

EH-D16ETPS

EH-D16ETN

EH-D28EDTP

EH-D28EDTPS

EH-D28EDTN

EH-D28EDR

EH-A28EDR

EH-D64EDT

EH-D64EDTPS

EH-D64EDR

EH-A64EDR

EH-D6EAN

EH-A6EAN

EH-D4ERTD

EH-A4ERTD

EH-D6ERTD

EH-A6ERTD

EH-OB232

EH-OB485

EH-MCB01

EH-MCB05

EH-MCB10

Approvals

1 - 9

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Accessories

Description Cat. No. Price $

RS232C port with 2 AI, 0-10 V DC for 20, 40 and 64 I/O base units - Plug on module

RS485 port with 2 AI, 0-10 V DC for 20, 40 and 64 I/O base units - Plug on module

Memory unit for backup of a user program - Plug on module

USB to serial converter (RS232C) - Plug on Module

USB to serial converter (RS232) Plug in Cable

Battery Standard for 23 or 28 I/O base units

Battery Long for 23 or 28 I/O base units

Battery Long for 20, 23, 28, 40 and 64 I/O base units

External Power supply 24 V DC, 3.5 Ampere power supply

External Power supply 24 V DC, 5 Ampere power supply

Programming Software

Description Cat. No. Price $

Programming software for EH Micro base units, 10, 14, and 28 I/O

Programming software for EH Micro

Programming software for EH Micro/EH150/H200/H250/H252

Programming cable, PLC to PC, (9 pin D), 200 cm

ACTWINCD 1)

ACTWINM1 1)

ACTWINH 1)

CBL-1509

Refer catalogue SI-E108U

Price Schedule ‘B3’

Micro programmable logic

controllersEH Micro series – Ordering details

EH-OB232

EH-OB485

EH-OBMEM

EH-OBUSB

USB-COM

EH-MBAT

EH-MBATLC

EH-MBATL

XCSP85C

XCSP120C

EH-OBUSB

EH-OB232

Notes: 1) Read about software on page 1 - 6.

14-point type, 8/16-point expansion unit 20/40-point type

64-point type23/28-point type

10-point type

70 80 80 90 80 90

80 9080 90

6575 47 85

95140150

76 8.4185195

140150

4.8 4.

8

4.8

Dimensions (mm)

76 8.4

10 I/O base

23/28 I/O bases 64 I/O base, 64 I/O expansions

Elevation 10 I/O 14 I/O base, 8/16 expansions

Elevation 14/20/23/28/40/64 I/O

20/40 I/O bases

Approvals

1 - 10

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Modular programmable logic controllersEH-150 series

Refer catalogue SI-E103Y

Flexible networking possibilitiesApprovals

Quality Control

Programming

Terminal

Adroit

SCADA

Ethernet IEEE802.3

Optical Link Coaxial Link

Web Controller EH-150 EH-150

H252EH-150 RS-422 up to 32 units connectable

EH-Micro 20/23/28/40/64 I/O

EH-150 EH-150 H252 H-302~H-4010H-302~H-4010

ESA HMI Third PartyDeviceNet™ Slaves

EH-150DeviceNet™ Slave

Third PartyProfibus® Slaves

EH-150Profibus® Slave

1 - 11

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

CPUs

Description Cat. No. Price $

Up to 512 I/O, Up to an 8 slot rack, No expansion racks possible, 4 K flash, 2 Ports @ 19.2 kbpsUp to 1,024 I/O, Up to an 8 slot rack, Up to 1 expansion rack of up to 8 slots, 8 K Flash, 2 Ports @ 38.4 kbps, Real Time Clock, Modem ControlUp to 1,024 I/O, Up to an 8 slot rack, Up to 1 expansion rack of up to 8 slots, 16 K Flash, 2 Ports @ 38.4 kbps, Real Time Clock, Modem Control, Additional Control FunctionsUp to 2,112 I/O, Up to an 11 slot rack, Up to 2 expansion racks of up to 11 slots, 16 K Flash, 2 Ports @ 38.4 kbps, Real Time Clock, Modem Control, Additional Control FunctionsUp to 3,520 I/O, Up to an 11 slot rack, Up to 4 expansion racks of up to 11 slots, 48 K Flash, 2 Ports @ 38.4 kbps, Real Time Clock, Modem Control, Additional Control FunctionsBase Rack Power Supply Modules

Input from 85 to 264 V AC / Output, 3.8 ampere @ 5 V DC and 0.4 ampere @ 24 V DCInput 21.6 to 26.4 V DC / Output, 3.8 ampere @ 5 V DCBase Racks

Space for Power supply and CPU and 3 slots for I/O modulesSpace for Power supply and CPU and 5 slots for I/O modulesSpace for Power supply and CPU and 8 slots for I/O modulesSpace for Power supply and CPU and 11 slots for I/O modules, Requires EH-CPU516 and aboveMemory Modules

Stores up to 48 K steps of user program for EH-CPU316 and aboveStores up to 16 K steps of user program and stores 384 K words of memory data for EH-CPU316 and above I/O Controller

Required for each expansion rack if not using Profibus, or Devicenet slavesLinking cable between racks and the EH-IOCH I/O controller, 1 meter longCommunication Modules

Devicenet master, 256 word input, 256 word output. Requires EH-CPU316 and above. Up to 2 masters can be installed per CPU in LINK mode and 4 in REMOTE mode. Up to 63 slaves can be controlled by each masterDevicenet slave (check compatibility of I/O)Profibus master, 256 word input, 256 word output. Requires EH-CPU316 and above. Up to 2 masters can be installed per CPU. Up to 124 slaves can be controlled by each master Profibus slave (check compatibility of I/O)Ethernet, IEEE802.3 standard, 10 BASE-T, TCP or UDP. Requires EH-CPU316, or aboveSerial communications, Modbus RTU, Modbus ASCII, RS232C port and RS232C/422/485 port. Requires EH-CPU516 and aboveCPU Link Modules – Requires EH-CPU 316 and above

Coaxial Link, 1.0 Mbps, Up to 500 meters between stations. Up to 64 stationsOptical Link, 1.0 Mbps, Up to 1,000 meters between stations. Up to 64 stations

Price Schedule ‘A4’

Refer catalogue SI-E103Y

EH-I0CD

EH-CPU104

IntroductionThe EH-150 series of PLCs incorporates the most advanced technologies in its compact body, such as a 32 bit RISC chip microcomputer for high speed arithmetic operations and a large flash memory. A big range of modular hardware options allows systems to be tailored to the requirements of each application, while spending a minimum on capital outlay and permitting future upgrades and expansions. The EH-150 series can easily network with other PLCs in the Hitachi range and it supports several common fieldbus systems, such as Ethernet, Profibus, Modbus and DeviceNet™ allowing communication with third party devices.

Modular programmable logic controllersEH-150 series

Ordering details – EH-150 series

EH-CPU548

EH-RMD

Approvals

EH-CPU104

EH-CPU208

EH-CPU316

EH-CPU516

EH-CPU548

EH-PSA

EH-PSD

EH-BS3

EH-BS5

EH-BS8

EH-BS11

EH-MEMP

EH-MEMD

EH-IOCH

EH-CB10

EH-RMD

EH-IOCD

EH-RMP

EH-IOCP

EH-ETH2

EH-SIO

EH-LINK

EH-OLINK

1 - 12

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

DC Input Modules

Description Cat. No. Price $

16 DI, 24 V DC, Removable screw terminal block

32 DI, 24 V DC, Plug connector

64 DI, 24 V DC, Plug connector

8 DI, 24 V DC, Removable screw terminal block

16 DI, 24 V DC, 16 millisecond filter, Removable screw terminal block

32 DI, 24 V DC, 16 millisecond filter, Plug connector

32 DI, 24 V DC, Euro cage clamp connector

32 DI, 24 V DC, 16 millisecond filter, Euro cage clamp connector

High Density Input Interface Board and Cable

32 Input terminal interface board

Cable for 32/64-point Input modules (Connectors at both ends)

AC Input Module

16 DI, 100 to 120 V AC, Removable screw terminal block

16 DI, 200 to 240 V AC, Removable screw terminal block

DC Output Module

16 DO, 12 to 24 V DC, PNP Transistor, Removable screw terminal block

32 DO, 12 to 24 V DC, PNP Transistor, Plug connector

64 DO, 12 to 24 V DC, PNP Transistor, Plug connector

16 DO, 12 to 24 V DC, NPN Transistor, Removable screw terminal block

32 DO, 12 to 24 V DC, NPN Transistor, Plug connector

64 DO, 12 to 24 V DC, NPN Transistor, Plug connector

8 DO, 12 to 24 V DC, NPN Transistor, Removable screw terminal block

8 DO, 12 to 24 V DC, PNP Transistor, Removable screw terminal block

16 DO, 12 to 24 V DC, PNP Transistor with Short Circuit Protection, Removable screw terminal block

32 DO, 12 to 24 V DC, NPN Transistor, Euro cage clamp connector

32 DO, 12 to 24 V DC, PNP Transistor, Euro cage clamp connector

High Density Output Interface Board and Cable

16 Output relay interface board

Cable for 32 and 64-point Output modules (Connectors at both ends)(PNP Only)

Cable for 32 and 64-point Output modules (Connectors at both ends)(NPN Only)

Plug in relay for EHRLY16

AC Output Module

16 DO, 100/240 V AC, Triac, Removable screw connector

4 DO, 100/240 V AC, Triac, Removable screw connectorRelay Output Module

16 DO, Relay, 2 ampere, Removable screw terminals

8 DO, Relay, 2 ampere, Isolated commons, Removable screw terminals

12 DO, Relay, 2 ampere, Removable screw terminals High Function Module

2 High Speed Counter Inputs, 32 bit, Up to 100 KHz, 1, or 2 phase, 2-point open collector output, Plug connector

Cable for EH-CU counter module. 30 to 34 socket.Interface board for EH-CBLCU counter cable. Cage clamp connectors 34 pin/point2 High Speed Counter Inputs, 32 bit, Up to 100 KHz, 1, or 2 phase, 2-point open collector output, Euro cage clamp connector

EH-XD16

EH-XD32 1)

EH-XD64 1)

EH-XD8

EH-XDL16

EH-XDL32 1)

EH-XD32E

EH-XDL32E

EHTRM32

EHCBLIN32

EH-XA16

EH-XAH16

EH-YTP16

EH-YTP32 2)

EH-YTP64 2)

EH-YT16

EH-YT32 2)

EH-YT64 2)

EH-YT8

EH-YTP8

EH-YTP16S

EH-YT32E

EH-YTP32E

EHRLY16

EHCBLOUT32PNP

EHCBLOUT32NPN

40.51-24 VDC

EH-YS16

EH-YS4

EH-YR16

EH-YR8B

EH-YR12

EH-CU

EH-CBLCU

289-506

EH-CUE

Price Schedule ‘A4’

Refer catalogue SI-E103Y

Modular programmable logic controllersEH-150 series (Cont’d)Ordering details

Notes: 1) Requires 1 (2) High density input interface board(s) and 1 (2) cable(s) for 32 (64) input module. 2) Requires 2 (4) High density output interface boards and 1 (2) cable(s) and 32 (64) relays for 32 (64) output module.

EH-YR16

EH-XD32

EH-XD64

EH-XD16

Approvals

1 - 13

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Modular programmable logic controllersEH-150 series (Cont’d)

Price Schedule ‘A4’

Refer catalogue SI-E103Y

Ordering details

Number of I/O modules

L1

L2

11

447

462.5

Base

Dimensions (mm)

EH-BS11

8

357

372.5

EH-BS8

5

267

282.5

EH-BS5

3

207

222.5

EH-BS3

Notes: 1) XCSF85C and XCSF120C power supplies are on Price Schedule ‘A2’.

EH-TC8

EH-YTP64

EH-POS

EH-CU

Approvals

Analogue Input Module

Description Cat. No. Price $

8 AI, 0-10 V DC, 12 bit resolution, Removable screw terminals

8 AI, -10 to +10 V DC, 12 bit resolution, Removable screw terminals

8 AI, 4-20 mA, 12 bit resolution, Removable screw terminals

4 AI, PT100, or PT1000 RTD, 15 bit signed resolution, Removable screw terminals

8 AI, Thermocouple types K,E,J,T,B,R,S,N selectable, 15 bit resolution

4 AI, 4-20 mA and 4 AI, 0-10 V DC, 12 bit resolution, Removable screw terminals

8 AI, 0-22 mA, 12 bit resolution, Removable screw terminals

8 AI, 0-22 mA, 4-22 mA, 0-10 V DC, selectable, 14 bit resolution, Removable screw terminals

Analogue Output Module

4 AO, 0-10 V DC, 12 bit resolution, Removable screw terminals

4 AI, -10 to +10 V DC, 12 bit resolution, Removable screw terminals

4 AO, 4-20 mA, 12 bit resolution, Removable screw terminals

2 AO, 4-20 mA and 2 AO, 0-10 V DC, 12 bit resolution, Removable screw terminals

2 AI, -10 to +10 V DC, 12 bit resolution, Removable screw terminals

8 AO, 0-22 mA, 4-22 mA, 0-10 V DC, selectable, 14 bit resolution, Removable screw terminals

Programming Items

Programming Software, (IEC 61131-3 compliant), site license

PC-PLC programming cable, 2 meters long, 9 pin female to RJ45

USB to serial converter, for when your laptop doesn't have a serial port

SYCON Profibus configuration software

Miscellaneous

Lithium Battery to backup data memory during power outage

Cover for unused slots in racks

DC power supplies

External Power supply 24 V DC, 3.5 Ampere power supply

External Power supply 24 V DC, 5 Ampere power supply

Positional control modules

Single axis, Plug connector

Four axis, Plug connector

EH-AX8V

EH-AX8H

EH-AX8I

EH-PT4

EH-TC8

EH-AX44

EH-AX8IO

EH-AXH8M

EH-AY4V

EH-AY4H

EH-AY4I

EH-AY22

EH-AY2H

EH-AYH8M

ACTWINH

CBL-1509

USB-COM

SYCON

LIBAT-H

EH-DUM

XCSP85C 1)

XCSP120C 1)

EH-POS

EH-POS4

IEC 61131-3 PROGRAMMING SOFTWARE

AUTOMATION SYSTEMS

FREEDevelopmentSoftware

ActWin licensed packagesActWin-M1

ActWin-H

For licensing, please contact your nearest

NHP representative.

Minimum system requirements

64 MB RAM, 25 MB free HDD space,

CD-ROM drive and Windows® 95/98 XP

or NT4.0/2000

1 - 15

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Micro and modular PLC accessory

selection guideEH-150 /

EH MICRO

ACTWINH

CBL-1509

EH150

-PGMCHH

-PGMGPH

EH150

- PGCB02H

+ RS05

N/A

EH Micro

-EHMCB10

-EHMCB05

-EHMCB01

EH150

-EHCB10

EHCBLOUT32

EHCBLIN32

EH 150-LIBATH

EH Micro-EHMBAT

PLC type

Software

PC to PLC

cables

Programmers

Programmer to

PLC cables

Programmer to

PC cables

Base/main to

expansion rack

cables

Interface board

cables

EHRLY16

EHTRM32

HTRMBRD32

Batteries

EC / EM series

ACT-MINI

EM3 - CBLEM3

EC - CBLEC

PGMJ

PGMJR2

CNPG15

CBL-PGMJR

EM series

-CNM01

-CNM06

-CNM10

-CNMS10

N/A

N/A

Mitsubishi

Alpha 2

AL-PCSWIN-E

AL-232CAB

Via front panel

N/A

N/A

N/A

N/A

N/A

H200/250/252

H Board

ACTWINH

CBL-90H

PGMCHH

PGMGPH

PGCB-02H

N/A

CNM-01

CNM-06

CNM-10

CNM-S10

CBLHOUT32

CBM-02

LIBAT-H

H300/700/2000

302/702/1002/2002,

ACTWINH

CBL-90H

PGMCHH

PGMGPH

PGCB-02H

N/A

1st rack (W/CPU)

CBL-05H

CBL-10H

Rack to rack

(Expansions)

CBE-05H

CBE-10H

N/A

LIBAT-H

Cable guide

EC SERIES

(Discontinued)

Mitsubishi Alpha 2

Mitsubishi Alpha

(Discontinued)

H200/250/252

SERIES

(Discontinued)

EM SERIES

(Discontinued)

PGMJ-R2

(Discontinued)CABLE ONBOARD PROGRAMMER

EH MICRO SERIES

EH-150

SERIES

EHCBLOUT32

EHCBLIN32

CBLHOUT32

CBM-02

EHRLY16

EHTRM32

EHRLY16

HTRMBRD32

EM 3 SERIES

(Discontinued)

CBL-1509

AL-232CAB CBL-1509

AL-232CAB CBL-90H

CBL-EM3

CBL-EC

CNPG-15

CBL-PGMJR

1 - 16

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Optimum design of a Fieldbus node

The following requirements must be met in order to design an economic fieldbus node:

best possible modularity – 1, 2, 4 or 8 channel for standard I/Os – single channel for special functions

combination of digital and analogue I/Os including various voltage, power and instrumentation signal requirements within a node

sensors and actuators may be wired independently of the fieldbus fast coupling to the chosen fieldbus quick and clear marking facility easy handling with few additional accessories fast and easy wiring with high operational reliability RS 232/RS 485 communication modules, user configurable and easy to use

WAGO I/O-SystemFieldbus independent BUS terminal block

Quick adaption to standard fieldbus systems

Using the WAGO I/O-SYSTEM it is now possible: To proceed with external wiring of the I/O modules without knowledge of the fieldbus system to

be used simple snap-fit mounting of the respective fieldbus coupler to the wired modules when fieldbus system

is known This gives inventory reduction and greater availability of modules for many different fieldbus systems,by adaption of all modules with a single bus coupler chosen for that system.

Refer catalogue WFC2

DeviceNet

Profibus

Ethernet

Modbus

A huge

range of

fieldbus

connection

options

areavailable

1 - 17

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

WAGO I/O-SystemFieldbus independent BUS terminal block

Combination of different functionsOver 350 module types in the range

The combination of digital and analogue I/Os with different potentials, powers and measuring signals allows the realisation of user specific fieldbus nodes.

Wide choice of Fieldbus couplers with integrated supply terminal block for external 24 V DC

Digital inputs 1)Digital outputs 2) Analogue

inputs 3)

Analogue

outputs 4)

Special functions

Notes: 1) Supply terminal block for external 230 V AC. 2) Supply terminal block for external 24 V DC (electrical isolation). 3) Supply terminal block for external modification of reference potential. 4) Supply terminal block for external 5 V DC.

ProfibusInterbus CAN OpenDeviceNetModbusLONEthernet

Refer catalogue WFC2

Each node of the WAGO® I/O System can easily be assembled to match your existing fieldbus and I/O needs, or adapted to meet your changing requirements. One, two, four and eight channel I/O modules allow you to purchase the minimum amount of I/O that you need for your application. Nodes can each accommodate up to 64 multi-channel modules. The range of modules includes over 350 types to suit your diverse I/O needs. There are digital I/O, analogueI/O, and 16 specialty modules in the range with new modules being frequently developed. The specialty modules include counters, encoder inputs, RS 232 and RS 485 serial comms, AS-i, DALI/DSI, MP-bus, SSI and TTY 20 mA loop.

Flexibility Approvals

1 - 18

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Refer catalogue WFC2

WAGO I/O-System – 750 SeriesThe BUS terminal block

The universal basic module

Assembly Power jumper contacts on the field side

Slim design modules for assembly onto

DIN rail...

...secure connection with dovetails

Quick exchange of a bus

terminal block

...within the assembly – without tools Safe, automatic connection by gold-plated, self-cleaning, slide contacts.

Safe, automatic connection by tinned, self-cleaning slide contact, ground (earth) makes first

and breaks last

W x H 1) x D (mm) 12 x 64 x 100

Note: 1) From upper edge of carrier rail.

H

W

D

Exchange within the assembly

Data contacts

1 - 19

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

WAGO I/O-System – 750 SeriesThe BUS terminal block

The universal basic module

Marking of clamping units by coloured

miniature WSB markers

Yellow - digital inputs

Red - digital outputs

Green - analogue inputs

Blue - analogue outputs

Clear - supply and special

function terminal block

Different functions marked by transparent

coloured group marker carriers

Group marking carrier (can be withdrawn and

replaced) with large area for self marking

Vibration proof, fast and maintenance-free

wiring of 0.08 mm2-2.5 mm2/AWG 28-14

Function at locked position 1:

Power output to I/O group is off

Function at locked position 2: Easy fuse replacement via hinged cover

Diagnosis and status indication by LED for

safe start-up and system control

Signal tracing with wired conductors

Colour coded for identification/handling

Moulded marking of clamping units

CAGE-CLAMP connection Status indication Testing

Fuse holder

Refer catalogue WFC2

1 - 20

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

WAGO I/O-SystemFieldbus independent BUS terminal block

Automation in industry

Complex production equipment such as that used in automated manufacturing industries use large numbers of sensors and actuators.Use of a fieldbus system and distributed control can considerably reduce costs.Fieldbus nodes (the fieldbus connection + I/O points) are of special importance in this context. If these are properly designed much of the cost can be minimised.

Typical node featuring optional Quick Connect I/O modules

A WAGO I/O node may be physically divided into several parts and the Data bus extended for up to 5 metres using Extension modules and standard RJ45 connectors and cables. A free software tool and a 750-920 programming cable is also required.

Extended WAGO I/O node example Internal Data Bus Extension Coupler Modules

1 - 21

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Profibus DP/V1, 12 MBaudDeviceNet, 125-500 KbaudEthernet TCP/IP 10 Mbit/sEthernet TCP/IP 10/100 Mbit/sModbus RS 485, 150-19200 baudProfibus DP, 12 MBaud (economy)DeviceNet, 125-500 Kbaud (economy)Programmable Fieldbus controller - Stocked

Profibus DP/V1, 12 MBaudProfiNet TCP/IP, 100 Mbit/sEthernet TCP/IP 10 Mbit/sEthernet TCP/IP 10/100 Mbit/sEthernet TCP/IP 10/100 Mbit/s, with RS232 serial portFieldbus couplers / Economy fieldbus couplers (smaller process image) - Indent 1)

Profibus DP, 1.5 MBaud, fibre opticProfiNet TCP/IP, 100 Mbit/sProfiNet TCP/IP, 100 Mbit/s, 2 portEthernet, Powerlink, 10/100 Mbit/s, V2, ARP, HTTP, DNS,SNTP, FTPModbus RS 232, 150-19200 baudModbus RS 485, 1.2-115.2 KbaudModbus RS 232, 1.2-115.2 KbaudCANopen, 10 Kbaud - 1 Mbaud, MCSCANopen, 10 Kbaud - 1 Mbaud, D-SubLON, FTTPeer to Peer, FTTInterbus, 500 KBaudInterbus, fibre opticCAL, 10 Kbaud - 1 MbaudFirewire, 100 MBaud, 200 MBaud, 400 MBaudCC-Link, 156 KBaud, 10 MbaudII/O-Lightbus, 2.5 MBaudII/O-Lightbus, 2.5 MBaud, digital signals onlySDSSercoss IIIInterbus, 500 KBaud (economy)Interbus, 2 MBaud (economy)CANopen, 10 Kbaud - 1 Mbaud, MCS (economy)CANopen, 10 Kbaud - 1 Mbaud, D-Sub (economy)Programmable Fieldbus controller - Indent 1)

DeviceNet, 125-500 KbaudEthernet TCP/IP 10/100 Mbit/s, 2 portEthernet TCP/IP 10/100 Mbit/s, 2 port, integrated switchLON, FTTModbus RS 485, 150-19200 baudModbus RS 232, 150-19200 baudModbus RS 485, 1.2-115.2 KbaudModbus RS 232, 1.2-115.2 KbaudInterbus, 500 KBaudCANopen, 10 Kbaud - 1 Mbaud, MCSCANopen, 10 Kbaud - 1 Mbaud, D-SubBACnet/IPKNXnet/IPLinux, 32-bit ARM CPU, 44 MHz, 16 MB RAM, 2.5 MB for JFFS2, BSP with 2.6 kernel, CGI

750-333

750-306

750-342

750-341

750-312

750-343

750-346

750-833

750-840

750-842

750-841

750-873

750-331

750-340

750-370750-350

750-314

750-315

750-316

750-337

750-338

750-319

750-319/004-000

750-304

750-334

750-305

750-339

750-310

750-300

750-320

750-313

750-351

750-344

750-345

750-347

750-348

750-806

750-871

750-881

750-819

750-812

750-814

750-815

750-816

750-804

750-837

750-838

750-830

750-849

750-860

Fieldbus couplers / Economy fieldbus couplers (smaller process image) - Stocked

750-343

Eco-Coupler

750-306

DeviceNet

750-333

Profibus

WAGO I/O System – 750 Series

750-833

Programmable

Price Schedule ‘A4’

Notes: 1) WAGO indent items have a typical delivery time of 2-3 weeks. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP.

Description Cat. No. Price $

1 - 22

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Notes: 1) WAGO indent items have a typical delivery time of 2-3 weeks. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP.

Refer catalogue WFC2

Price Schedule ‘A4’

750-400

750-430

750-424

750-530

750-523

WAGO I/O System – 750 Series

4 DI, DC 5 V, 0.2 ms, 2 to 3 connection, PNP2 DI, DC 24 V, 3.0 ms, 2 to 4 connection, PNP2 DI, DC 24 V, 0.2 ms, 2 to 4 connection, PNP4 DI, DC 24 V, 3.0 ms, 2 to 3 connection, PNP4 DI, DC 24 V, 3.0 ms, 2 connection, PNP4 DI, DC 24 V, 0.2 ms, 2 to 3 connection, PNP4 DI, DC 24 V, 3.0 ms, 2 to 3 connection, NPN8 DI, DC 24 V, 3.0 ms, 1 connection, PNP8 DI, DC 24 V, 0.2 ms, 1 connection, PNP4 DI, AC/DC 24 V, 2 connection2 DO, DC 24 V, 0.5 A, short-cct-protected, PNP2 DO, DC 24 V, 2.0 A, short-cct-protected, PNP4 DO, DC 24 V, 0.5 A, short-cct-protected, PNP4 DO, DC 24 V, 0.5 A, 2 connection, short-cct-protected, PNP8 DO, DC 24 V, 0.5 A, NPN8 DO, DC 24 V, 0.5 A, short-cct-protected, PNP2 DO, AC 125 V, AC 0.5 A, DC 30 V, DC 1 A, isol o/pts, 2 C/O2 DO, AC 230 V, 1 A, isolated outputs, 2 c/o contacts2 DO, AC 230 V, DC 30 V, AC/DC 2 A, non-float, 2 make cntcts2 DO, AC 230 V, DC 30 V, AC/DC 2 A, isol o/pts, 2 make cntctsDigital Input modules / Digital Output modules - Indent 1)

2 DI, DC 24 V, 3.0 ms, Prox-Sw, 2 to 4 connection, PNP2 DI, DC 24 V, 0.2 ms, Prox-Sw, 2 to 4 connection, PNP2 DI, DC 24 V, 3.0 ms, 2 to 3 connection, PNP, with diagnostics2 DI, DC 24 V, 3.0 ms, PNP, with diagnostics4 DI, DC 24 V, 0.2 ms, 2 connection, PNP4 DI, DC 24 V, 2 to 3 connection, PNP, pulse extension 10 ms4 DI, DC 24 V, 0.2 ms, 2 to 3 connection, NPN8 DI, DC 24 V, 3.0 ms, 1 connection, NPN8 DI, DC 24 V, 0.2 ms, 1 connection, NPN4 DI, AC/DC 24 V, 2 to 3 connection with power contacts4 DI, AC/DC 24 V, 2 connection2 DI, DC 48 V, 3.0 ms, 2 to 4 connection, PNP2 DI, DC 110 V, configurable high-side or NPN2 DI, AC 120 V, 2 to 4 connection2 DI, AC 230 V, 2 to 4 connection2 DI, NAMUR, Proximity switch acc. to DIN EN 502272 DI, DC 24 V, Intruder detection4 DO, DC 5 V, 20 mA, short-cct-protected, PNP2 DO, DC 24 V, 0.5 A, with diagnostics, short-cct-protected, PNP2 DO, DC 24 V, 2.0 A, with diagnostics, short-cct-protected, PNP4 DO, DC 24 V, 0.5 A, TYPE N, short-cct-protected, NPN4 DO, DC 24 V, 0.5 A, with diagnostics, PNP8 DO, DC 24 V, 0.5 A, with diagnostics, PNP2 DO, Solid State Relay, AC/DC 230 V, 300 mA2 DO, Solid State Relay, AC/DC 230 V, 500 mA, 3 A (< 30 s)1 DO, AC 230 V, AC 16 A, isol output, 1 make cntct, bistable

750-414

750-400

750-401

750-402

750-432

750-403

750-408

750-430

750-431

750-415

750-501

750-502

750-504

750-531

750-536

750-530

750-514

750-517

750-512

750-513

750-410

750-411

750-418

750-421

750-433

750-422

750-409

750-436

750-437

750-423

750-428

750-412

750-427

750-406

750-405

750-425

750-424

750-519

750-506

750-508

750-516

750-532

750-537

750-509

750-522

750-523

Digital Input modules / Digital Output modules - StockedDescription Cat. No. Price $

1 - 23

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘A4’

Refer catalogue WFC2

WAGO I/O System – 750 Series

750-452

750-457

750-491

750-557

Notes: 1) WAGO indent items have a typical delivery time of 2-3 weeks. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP.

750-493

Analogue Input / Analogue Output modules - Stocked

4-channel, 0 - 20 mA, single ended, 12 Bit2-channel, 0 - 20 mA, differential inputs, 14 Bit2-channel, 4 - 20 mA, differential inputs, 12 Bit4-channel, 4 - 20 mA, single ended, 12 Bit2-channel, 4 - 20 mA, single ended, 15 Bit2-channel, 4 - 20 mA, single ended, 12 Bit2-channel, 4 - 20 mA, isolated differential inputs, 12 Bit4-channel, DC 0 - 10 V, single ended, 12 Bit4-channel, DC ± 10 V, single ended, 12 Bit2-channel, DC ± 10 V, Diff. measurement input, 14 Bit2-channel, DC0 - 30 V, Diff. measurement input, 14 Bit2-channel, input module for RTDs, PT100 / RTD, 16 Bit4-channel, 0 - 20 mA, 12 Bit2-channel, 4 - 20 mA, 12 Bit4-channel, 4 - 20 mA, 12 Bit2-channel, DC 0 - 10 V, 12 Bit4-channel, DC 0 - 10 V, 12 Bit4-channel, DC ± 10 V, 12 BitAnalogue Input / Analogue Output modules - Indent 1)

2-channel, 4-20 mA, HART, 4 variables per channel, FDT tool routing to DTM, 12 bit3-phase power measurement, to 500 V AC, 1 A, 0.5 % error, 16 bit3-phase power measurement, to 500 V AC, 5 A, 0.5 % error, 16 bit2-channel, 0 - 20 mA, differential inputs, 12 Bit2-channel, 0 - 20 mA, single ended, 12 Bit2-channel, 0 - 20 mA, single ended, 15 Bit2-channel, 4 - 20 mA, single ended, short circuit protected, 12 Bit2-channel, 0 - 1 A AC/DC, differential inputs, 16 Bit4-channel, DC 0 - 10 V, single ended, 12 Bit2-channel, DC 0 - 10 V, single ended, 12 Bit2-channel, AC/DC 0 - 10 V, differential inputs, 16 Bit2-channel, DC 0 - 10 V, single ended, 16 Bit2-channel, DC ± 10 V, differential inputs, 12 Bit2-channel, DC ± 10 V, single ended, 14 Bit4-channel, input module for RTDs, PT100 / RTD, 16 Bit2-channel, thermocouple, K Type, -100 °C to +1370 °C, 16 Bit2-channel, thermocouple, S Type, 0 °C to +1700 °C, 16 Bit2-channel, thermocouple, T Type, -100 °C to +400 °C, 16 Bit2-channel, thermocouple, +/- 120 mV, 16 Bit2-channel, thermocouple, J Type, -100 °C to +1200 °C, 16 Bit2-channel, thermocouple, E Type, -100 °C to +1000 °C, 16 Bit2-channel, thermocouple, L Type, -25 °C to +900 °C, 16 Bit2-channel, thermocouple, Configurable Temp range with I/O Check1-channel input module for resistor bridge (Strain gauge), 16 Bit, 250 msec conversion1-channel input module for resistor bridge (Strain gauge), 16 Bit, 65 msec conversion2-channel, 0 - 20 mA, 12 Bit2-channel, DC 0 - 10 V, 100 mA, 24 V, 8 Bit2-channel, DC ± 10 V, 12 Bit

750-453

750-480

750-454

750-455

750-474

750-466

750-492

750-468

750-457

750-479

750-483

750-461

750-553

750-554

750-555

750-550

750-559

750-557

750-482

750-493

750-493/000-001

750-452

750-465

750-472

750-473

750-475

750-459

750-467

750-477

750-478

750-456

750-476

750-460

750-469/00000

750-469/000001

750-469/000002

750-469/000003

750-469/000006

750-469/000008

750-469/000012

750-469/003000

750-491

750-491/000-001

750-552

750-560

750-556

Description Cat. No. Price $

1 - 24

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Refer catalogue WFC2

Price Schedule ‘A4’

WAGO I/O System – 750 Series

750-404

Vibration Module

750-645

Vibration Sensor

750-925

Notes: 1) WAGO indent items have a typical delivery time of 2-3 weeks. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP.

2-channel, Vibration velocity/Shock pulse, Bearing condition monitoringUp/Down Counter, DC 24 V, 100 kHz2-channel Up/Down Counter, DC 24 V / 16 Bit / 500 HzSerial Interface RS 232 C – ConfigurableSerial Interface RS 485 – ConfigurableModule Bus Extension, End ModuleModule Bus Extension, Coupler ModuleDC 24 V, passiveDC 24 V, max. 6.3 A, without diagnostics, with fuse-holderDC 24 V, max. 6.3 A, with diagnostics, with fuse-holderFilter Module, System and field side pwr supply filter with surge protField Side Connection Module, DC 0 VField Side Connection Module, DC 24 VSeparation ModuleEnd Module, to loop the internal busSpecialty / System modules - Indent 1)

Bluetooth, 2.4 GHz ISM band, Class 1 (100 metres), Master/SlaveExternal antenna for Bluetooth module 750-644, magnetic standBluetooth, serial port adaptor for linking coupler/controller to laptop PC, Class 2Tandem Piezo vibration sensor for Vibration module 750-645Real Time Clock, 32 channel integrated time switch2-channel Pulse Width Module, DC 24 V, short-cct-prot, PNPSSI Transmitter InterfaceIncremental Encoder Interface, TTL level squarewaveIncremental Encoder Interface, RS 422, cam outputsIncremental Encoder Interface, DC 24 VDigital Impulse InterfaceTTY-Serial Interface, 20 mA Current LoopData Exchange ModuleDALI/DSI Master ModuleAS-interface Master ModuleRF-Receiver EnOceanMP-Bus (Multi Point-Bus) Master ModuleStepper Controller, RS422, 24 V DC, 20 mA interfaces, 30 mA outputStepper Controller, 24 V DC, 2-phase, 2 x 1.5 A outputsDC Drive controller, 24 V DC, 5 A output, incremental encoder interface, end stop inputsBus Power Supply, DC 24 VSupply Module, 24 V DC input, selectable 5,8,10,12,15 V DC outputs, 0.5 A, 1 A @ 5 V DCAC 120 V, max. 6.3 A, without diagnostics, with fuse-holderAC/DC 230 V, without diagnostics, passiveAC 230 V, max. 6.3 A, without diagnostics, with fuse-holderAC 230 V, max. 6.3 A, with diagnostics, with fuse-holderFilter Module, Field side power supply filter with o/voltage protField Side Connection Module, AC/DC 0 ...230 VSeparation Module with Power ContactsBinary Spacer Module

Specialty / System modules - Stocked

750-645

750-404

750-638

750-650/003000

750-653/003000

750-627

750-628

750-602

750-601

750-610

750-626

750-604

750-603

750-616

750-600

750-644

758-912

750-921

750-925

750-640

750-511

750-630750-631/000-004

750-637

750-634

750-635

750-651

750-654

750-641

750-655

750-642

750-643

750-670

750-671

750-636

750-613

750-623

750-615

750-612

750-609

750-611

750-624

750-614

750-621

750-622

Description Cat. No. Price $

1 - 25

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Refer catalogue WFC2

Price Schedule ‘A4’

AccessoriesDescription Cat. No. Price $

PROFIBUS, Bus connector with D-SUB male connector, 9 pole

PROFIBUS, Bus connector with D-SUB male and female, 9 pole

INTERBUS (IN), Bus connector with D-SUB female, 9 pole

INTERBUS (OUT), Bus connector with D-SUB male, 9 pole

CANopen, Bus connector with D-SUB female connect, 9 pole

CC-Link, Bus connector with D-SUB male connecter, 9 pole

Multi-Port Device Taps, 2 trunk Cable (in/output), 4 drop cables

Multi-Port Device Taps, 2 trunk Cable (in/output), 2 drop cables

Multi-Port Device Taps, 2 trunk Cable (in/output), 1 & 2 drop cables

Programming/configuration cable from laptop/PC to Controller/D-ConnectorBluetooth, serial port adaptor for linking coupler/controller to laptop PC, Class 2 Programming/configuration cable from laptop/PC to Controller, USB-connectorPower Supply for AS-Interface, Input 90 to 264 V AC, Output 30.5 V DC, 3.0 APower Supply, Input 90 to 264 V AC, Output 1.0 A V DC, Cage Clamp connectorsPower Supply, Input 90 to 264 V AC, Output 2.5 A V DC, Cage Clamp connectors

Extended Temperature Range from -20° to +60 °C

Ethernet Controller, 100 Mbit/s, EXTModbus Controller RS-485, 150-19, 200 Bd EXTModbus Controller RS-485, 1.2-115.2 KBd EXTProfibus coupler, DP/V1, 12 MBd, EXTProfibus controller, DP/V1, 12 MBd, EXTCANopen coupler, EXT2 Digital Input, 24 V DC, 3.0 msec, EXT4 Digital Input, 24 V DC, 3.0 msec, EXT8 Digital Input, 24 V DC, 3.0 msec, EXT4 Digital Output, 24 V DC, 0.5 A, EXT8 Digital Output, 24 V DC, 0.5 A, EXT2 Analogue Input, 4-20 mA, Single Ended, EXT4 Analogue Input, 4-20 mA, Single Ended, EXT4 Analogue Input, 4-20 mA, Differential, EXTSupply module, 24 V DC, EXTSerial Interface, RS-485, 9600/n/8/1/5 Byte Cont., EXTSerial Interface, RS-485, Configurable, EXT

750-960

750-970

750-961

750-962

750-963

750-965

810-900/000-001

810-901/000-001

810-902/000-001

750-920

750-921

750-923

787-692

787-602

787-612

750-841/025-000

750-812/025-000

750-815/025-000

750-333/025-000

750-833/025-000

750-337/025-000

750-400/025-000

750-402/025-000

750-430/025-000

750-504/025-000

750-530/025-000

750-466/025-000

750-455/025-000

750-454/025-000

750-602/025-000

750-653/025-018

750-653/025-000

WAGO I/O System – 750 Series 1)

Notes: 1) Please check availability. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP.

750-960

750-970

288-824

810-901/000-001

810-902/000-001

750-921

1 - 26

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

WAGO I/O System – 857 Series

JUMPFLEX Transducers

Refer catalogue WFC2

Multi-Talented With High ProfileA complete product line is available, bringing each signal into

shape.

The perfect match of housing and electronics is the key to a highly successful device. This goal has been achieved by WAGO with the new family of transducers and relay modules Series 857.

Features:

“True” 6.0 mm/0.236” width Extended range of temperatures from -25 °C to +70 °C “Safe isolation” with 2.5 kV test voltage Configuration via DIP switch CAGE CLAMP® S connection – fast – reliable – maintenance free

solid

AWG 28 … 12 (0.08 mm2 … 2.5 mm2)

ferruled

AWG 22 … 14 (0.25 mm2 … 1.5 mm2)

fine-stranded

AWG 22 … 12 (0.34 mm2 … 2.5 mm2)

Vibration Proof - Fast - Maintenance FreeCAGE CLAMP® S connection for all types of wires.

For Extreme ApplicationsExtended range of temperatures from -25 °C to +70 °C allows for wide application areas.

1 - 27

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Description Specifications Cat. No. Price $

Isolation Amplifier Input: 0(4) - 20 mA, 0(1) - 5 V, 0(2) - 10 V

(Configuration via DIP Switch) Output: 0(4) - 20 mA, 0(1) - 5 V, 0(2) - 10 V

Isolation Current Amplifier Input: 0(4) - 20 mA

(Fixed Settings) Output: 0(4) - 20 mA

Isolation Voltage Amplifier Input: 0(2) - 10 V

(Fixed Settings) Output: 0(2) - 10 V

Power Supply Transducers

Repeater Power Supply Input: 0(4) - 20 mA

(Configuration via DIP Switch) Output: 0(4) - 20 mA, 0(1) - 5 V, 0(2) - 10 V

Repeater Power Supply, HART Input: 4 - 20 mA

(Fixed Settings) Output: 4 - 20 mA

Signal Splitter Input: 0(4) - 20 mA, 0(1) - 5 V, 0(2) - 10 V

(Configuration via DIP Switch) Output: 2 x 0(4) - 20 mA

Isolator Transducers

Passive Isolator, 1 Channel Input: 0(4) - 20 mA

(Fixed Settings) Output: 0(4) – 20 mA

Passive Isolator, 2 Channels Input: 0(4) - 20 mA

(Fixed Settings) Output: 0(4) - 20 mA

Temperature Transducers

Transducer for RTDs Input: Pt 100, Pt 200, Pt 500, Pt 1000

(Configuration via DIP Switch) Output: 0(4) - 20 mA, 0(2) - 10 mA,

0(2) - 10 V, 0(1) - 5 V

Transducer for RTDs Input: Pt 100, Pt 200, Pt 500, Pt 1000

(Configuration via DIP Switch Output: 0(4) - 20 mA, 0(2) - 10 mA,

or Software) 1) 0(2) - 10 V, 0(1) - 5 V

Transducer for Thermocouples Input: Type J: -150 °C ... +1200 °C /

(Configuration via DIP Switch) Type K: -150 °C ... +1350 °C

Output: 0(4) - 20 mA, 0(2) - 10 mA,

0(2) - 10 V, 0(1) - 5 V

Transducer for Thermocouples Input: Type J: -150 °C ... +1200 °C /

(Configuration via DIP Switch Type K: -150 °C ... +1350 °C

or Software) 1) Output: 0(4) - 20 mA, 0(2) - 10 mA,

0(2) - 10 V, 0(1) - 5 V

Programming/configuration cable from laptop/PC to Controller, D-Connector

Bluetooth, serial port adaptor for linking coupler/controller to laptop PC, Class 2

Programming/configuration cable from laptop/PC to Controller, USB-connector

WAGO I/O System – 857 Series 2)

JUMPFLEX Transducers

Refer catalogue WFC2

Price Schedule ‘A4’

Highest SafetyAll devices provide “safe isolation” with 2.5 kV test voltage to EN 61140.

Flexibility at its FinestConfiguration via DIP switch.

Temperature transducers can also be configured via software.

Isolation Amplifier,

Configurable

Temperature

Transducer

for RTDs

Amplifier Transducers

857-400

857-412

857-411

857-420

857-421

857-423

857-451

857-452

857-800

857-801

857-810

857-811

750-920

750-921

750-923

Notes: 1) WAGO I/O Check Software (P/N 759-302 refer page 1 - 27) and WAGO Programming cable. 2) Please check availability.

1 - 28

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘A4’

Description Cat. No. Price $

EExi 1 channel digital input

EExi 2 channel digital input

EExi 2 channel digital output

EExi 1 channel analogue input 4-20 mA

EExi 1 channel analogue input RTD

EExi 1 channel analogue output 0-20 mA

EExi power supply 24 Volt fused

750-435

750-438

750-535

750-485

750-481

750-585

750-625

WAGO I/O-System – 750 Series Intrinsically Safe System for applications in Hazardous Areas

EExi Modules 1)

Notes: 1) Please check availability. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP.

WAGO-I/O-SYSTEM 750 - Now IECex approved, test certificates available

Today’s development shows that many chemical and petrochemical companies have production plants, production and process automation machines in operation, which use gas-air or dust-air mixtures which can be explosive. For this reason, the electrical components used in such plants and systems must not pose a risk of explosion resulting in injury to persons or damage to property.

The WAGO-I/O-SYSTEM 750 is designed for use in both hazardous and non-hazardous environments.

Using fieldbus technology in hazardous environments can be very time consuming and cost intensive and is only made possible in a limited way. When used in hazardous areas of Zone 2, the WAGO-I/O-SYSTEM 750 offers a safe, easy an economical connection to the sensors and actuators of Zones 0 and 1.

The EExi I/O modules were specially developed for this purpose. They build up an intrinsically safe section, which can be integrated into a standard fieldbus node, offering all the advantages of state-of-the-art fieldbus technology (e.g. fieldbus independency, flexibility, modularity, programmability, reliability, cost effectiveness).

750-485

Now IECex approved, test certificates available

1 - 29

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Description Cat. No. Price $

Input - [8 Digital Inputs (Cat 2)] or [4 Digital Inputs (Cat 4)]

Output - [(4 DO + 4 DI) - (Cat 2)] or [(2 DI + 2 DO) - (Cat 4)]

Power Switch - [1 DO (Cat 3)] or [1 DI + 1 DO] - (Cat 4)

Input - [4 Digital Inputs (Cat 2)] or [2 Digital Inputs (Cat 4)]

Input - [8 Digital Inputs (Cat 2)] or [4 Digital Inputs (Cat 4)]

Output -[(4 DO + 4 DI) (Cat 2)] or [(2 DI + 2 DO (Cat 4)]

WAGO I/O-System – 750 Series PROFIsafeThe WAGO-I/O-System 750 integrates modules with SAFETY

functionality into the fieldbus node in accordance with industry

standards.

Price Schedule ‘A4’

Notes: 1) Please check availability. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP.

Refer catalogue WFC2

750-660

750-665

750-666

753-661

753-662

753-667

PROFIsafe modules 1)

The advantages

The same input module allows the connection of emergency switches, protection door switches, two-handed control devices, mode selectors, as well as other hardware based safe sensors.

All inputs of a module are monitored for cross short circuits which makes it possible to combine all sensors in one single cable.

Status, configuration and diagnostics are available in every module.

An output module can operate outputs with stop category 0 or 1. The outputs are also monitored for cross short circuits.

The power switch module offers the possibility to switch off various 24 V output modules (up to safety category 3) that shall be combined in one safety area.

All safety modules are connected to the master station via the PROFIsafe protocol. The master station takes care of initialisation, setting parameters and assignments.

This allows their use in safety applications up to category 4 in accordance with EN 954-1 or SIL 3 according to base standard IEC 61508 and AK 6-(DIN V 19250).

750-660

750-665

750-666

1 - 30

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘A4’

WAGO I/O-System – 750 Series

Vibration monitoringVibration monitoring and analysis is a well established and commonly used method of predictive maintenance. Motors, pumps, gear boxes, fans and many other types of rotating components of mechanical systems can fail unexpectedly and result in major production losses and expensive repairs. Many of these failures can be predicted by measuring the normal vibration levels of rotating components and watching for increases. Vibration monitoring and analysis equipment traditionally has been expensive and often separate to, or awkwardly integrated into factory control and maintenance systems. WAGO has developed a vibration monitoring system that overcomes many of the problems with existing vibration systems. The WAGO system consists of a vibration sensor that constantly measures both the mean value of the vibration severity and the “shock pulse” value. Two such sensors can be monitored by the new WAGO vibration module 750-645. The new module is fully compatible with all of the other modules in the WAGO remote I/O 750/753 series and with all WAGO standard couplers and WAGO controllers. This allows the vibration monitoring information to be transmitted back to a central control system along any of the popular fieldbus types. Limits can be set for the measured values of vibration and if these limits are exceeded then alarms can be raised and further investigation can be conducted, or if higher limits are exceeded the module can trigger a slow down, or a shut down of the equipment to protect it from damage. The module employs coloured LEDs to locally display the status of the module and to show if the alarm, or shut down limits have been exceeded. The new WAGO Vibration system thus provides another reason to choose WAGO I/O for all of your future remote I/O needs.

Ordering detailsDescription Cat. No. Price $

2-channel, Vibration velocity/Shock pulse, Bearing condition monitoring

Tandem Piezo vibration sensor for Vibration module 750-645

750-645

750-925

1 - 31

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Description Cat. No. Price $

Master Module

AS-interface Master Module, Specification 2.1 Compliant, Controls up to 62 AS-

interface Slaves, Gateway to other Fieldbus Systems, Compatible with “Safety at

Work”, Supports Analogue Data Transmission, Cyclic and Acyclic Communications,

Supports Extended Diagnostics, Configurable with WAGO-IO-CHECK

IP 67 I/O Modules

4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP), Standard Addressing

4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP), A/B Extended Addressing

4 Digital Outputs, 24 V DC/2A, Standard Addressing

4 Digital Outputs, 24 V DC/2A, 4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP),

Standard Addressing

3 Digital Outputs, 24 V DC/2A, 4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP),

A/B Extended Addressing

IP 20 I/O Modules

4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP), Standard Addressing

4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP), A/B Extended Addressing

4 Digital Outputs, 24 V DC/2A, Standard Addressing

4 Digital Outputs, 24 V DC/2A, 4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP),

Standard Addressing

3 Digital Outputs, 24 V DC/2A, 4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP),

A/B Extended Addressing

Power Supply

Input Voltage 100-240 V AC at 50 - 60 Hz or 140 - 300 V DC, Output Voltage

30.5 V DC at 3A, Overload ProtectionWAGO-I/O-CHECK

Configuration, start-up, and diagnostic software tool

WAGO I/O-System – 750 Series

AS-i Fieldbus System

Notes: 1) Please check availability. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP.

751-5701

IP 20 Casing

751-4001

IP 67 Casing

Price Schedule ‘A4’

For As-i safe components refer to NHP

750-655

751-3001

751-3002

751-4001

751-5201

751-5202

751-3501

751-3502

751-4501

751-5701

751-5702

787-692

759-302

AS-i Master and Slave Modules 1)

Ordering details

AS-i bus - up to 100 metres, or 300 metres with two repeaters

0800 NHP NHP nhp-nz.com1300 NHP NHP nhp.com.au

As an integrated group that spans across six key

business areas, the unique and complete NHP

package rests on a strong team of staff that pride

itself on a shared set of core company values.

Make NHP part of your business.

Think Quality Service. Think NHP.

THINK QUALITY SERVICE. THINK NHP.NHP is shaped by a team of over 850 quality staff dedicated to providing ‘what you want, when, where and how you want it’.

1 - 33

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Refer catalogue WFC2

Price Schedule ‘A4’

WAGO I/O-SystemProgramming and diagnostic software

I/O PROWAGO-I/O-PRO 32 is a programming and visualisation tool, allowing users to develop SPS applications for the Programmable Fieldbus Controller from the WAGO-I/O-SYSTEMS 750. WAGO-I/O-PRO conforms to IEC 61131-3. This standard defines the requirements fulfilled by a programming system as well as five programming languages for PLCs. The languages IL, LD, FBD, ST and FC are supported. For every automation task, the appropriate language can be chosen.The software meets the increasing requirements of control program development, for example re-usability or modularisation.

Powerful translation of the programming languages Automatic declaration of variables Librarian / library maintenance

Furthermore, integrated test and diagnostic functions facilitate and speed up PLC working processes.

Online status indication in the program code Offline simulation Integrated visual display of internal and external markers Storage and graphic display of project variables

I/O CHECKWAGO-I/O-CHECK is a WindowsTM application for the check of inputs and outputs and the display of nodes of the WAGO-I/O-SYSTEM 750. The software is easy to handle and it is not necessary to connect the node to a fieldbus system.The software reads out the node configuration and displays it as a graphic on the screen. This graphic can be printed out along with a configuration list, together being a complete documentation.With WAGO-I/O-CHECK it is possible to display and to determine the process data of the bus modules. The field wiring including all sensors and actuators, can thus be checked before startup.The communication between WAGO-I/O-CHECK and the node is made via the communication cable (included with the delivery) which is connected to the coupler and to a serial interface of the PC.

Note: 1) Includes: manual (electronic), communications cable and installation disks. 2) The software choice depends on the hardware and firmware that is being used. Ask your NHP automation specialist for advice. WAGO indent items have a typical delivery time of 2-3 weeks.

Accessory/Spare

759-332

759-333

Description Cat. No.

WAGO I/O PRO 1) 2)

WAGO I/O PRO CAA 1) 2)

Price $

759-302WAGO I/O CHECK 1)

Description Cat. No. Price $

750-920

750-921

750-923

Programming/configuration cable from laptop/PC to Coupler/controller, D-connector

Bluetooth, serial port adaptor for linking coupler/ controller to laptop PC, Class 2

Programming/configuration cable from laptop/PC to Controller, USB-connector

Description Cat. No. Price $

1 - 34

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘A4’

WAGO I/O-System – 750 Series Starter Kits 1)

Refer catalogue WFC2

ETHERNET StarterKit 1 Item No. 750-841 KITContent:

Type Description Item No.

Fieldbus controller ETHERNET TCP/IP 10/100 MBit/s 750-841+ basic components

ETHERNET StarterKit 2 Item No. 750-842 KITContent:

Type Description Item No.

Fieldbus controller ETHERNET TCP/IP 10 MBit/s 750-842+ basic components

Basic components

Type Description Item No.

Digital input module 2 DI 24 V DC 3.0 ms 750-400Digital output module 2 DO 24 V DC 0.5 A 750-501End module 750-600Power supply unit 24 V DC 1.3 A 787-602Software WAGO DLL MODBUS/TCP 759-312Programming software WAGO-I/O-PRO CAA 759-911CD-ROM Tools & Docs Documentation 0888- 0412/0001-010Programming cable 750-920

PROFIBUS StarterKit Item No. 750-833 KITContent:

Type Description Item No.

Fieldbus controller PROFIBUS DP/ V1 12 MBd 750-833Input module 2 DI 24 V DC 3.0 ms 750-400Input module 4 DI 24 V DC 3.0 ms 750-402Output module 8 DO 24 V DC 0.5 A 750-530Input module 2 AI 0 -10 V 750-478Output module 4 AO 0-10 V 750-559End module 750-600Power supply unit 24 V DC 1,3 A 787-602DEMO Programming software WAGO-I/O-PRO CAACD-ROM Documentation/GSD file 0888-0412/0001-0101

AS-Interface Expansion Kit Item No. 750-655 KIT 1)Content:

Type Description Item No.

Specialty module AS-Interface master (M3) V.2.1 750-655Power supply unit AS-Interface 30.1 V/3A 787-692AS-Interface slave IP 67 4 IN/3 OUT 24 V/2 A 751-5202AS-Interface slave IP 20 4 IN/3 OUT 24 V/2 A 751-5702Software WAGO-I/O-CHECK 759-302Bus cable 1 meter AS-Interface, yellow 2x1.5Bus cable 1 meter control cable, OB 500 2x1.0CD-ROM Documentation 0888-0412/0001-0101

IP 67 IP 20

AS-interface power

supply unit AS-interface master

Note: 1) AS interface expansion kit requires a WAGO controller and an end module. WAGO indent items have a typical delivery t ime of 2-3 weeks.

Description Cat. No. Price $

Ethernet Starter Kit 1

Ethernet Starter Kit 2

Profibus Starter Kit

ASinterface Starter Kit

750-841KIT

750-842KIT

750-833KIT

750-655KIT

1 - 35

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Refer catalogue WFC2

WAGO I/O-System – 753 SeriesQuick connect modules

Quick release by lever

Quick connect Secure cable locationMiniature marking

Coding Elements

Signal tracing with wired conductorsDiagnosis and status shown by LED

Removeable terminalsEasy insert

Quick release by lever Quick release by lever

Quick release by screwdriver Easy module removal

Colour coded modules

Easy module removal

1 - 36

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Refer catalogue WFC2

WAGO I/O-System – 753 SeriesQuick connect modules 1)2)

Notes: 1) Same size as the 750 series. 2) Please check availability. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP.

753-400

BxH 1) xT (mm) 12x65x100

Digital Input modules

Description Cat. No. Price $

2 DI, DC 24 V, 3.0 ms, 2 to 4 connection, PNP

2 DI, DC 24 V, 0.2 ms, 2 to 4 connection, PNP

2 DI, DC 24 V, 3.0 ms, Prox-Sw, 2 to 4 connection, PNP

2 DI, DC 24 V, 0.2 ms, Prox-Sw, 2 to 4 connection, PNP

2 DI, DC 24 V, 3.0 ms, 2 to 3 connection, PNP, with diagnostics

2 DI, DC 24 V, 3.0 ms, PNP, with diagnostics

4 DI, DC 24 V, 3.0 ms, 2 to 3 connection, PNP

4 DI, DC 24 V, 3.0 ms, 2 connection, PNP

4 DI, DC 24 V, 0.2 ms, 2 to 3 connection, PNP

4 DI, DC 24 V, 0.2 ms, 2 connection, PNP

4 DI, DC 24 V, 2 to 3 connection, PNP, pulse extension 10 ms

4 DI, DC 24 V, 3.0 ms, 2 to 3 connection, NPN

4 DI, DC 24 V, 0.2 ms, 2 to 3 connection, NPN

8 DI, DC 24 V, 3.0 ms, 1 connection, PNP

8 DI, DC 24 V, 0.2 ms, 1 connection, PNP

4 DI, AC/DC 24 V, 2 connection

4 DI, AC/DC 24 V, 2 to 3 connection with power contacts

4 DI, AC/DC 42 V, 2 connection

2 DI, DC 48 V, 3.0 ms, 2 to 4 connection, PNP

2 DI, DC 110 V, configurable high-side or NPN

2 DI, AC 120 V, 2 to 4 connection, PNP

2 DI, AC 230 V, 2 to 4 connection, PNP

2 DI, NAMUR, Proximity switch acc. to DIN EN 50227

2 DI, DC 24 V, Intruder detection

8 DI, DC 5 to 12 V, 0,2 ms, PNP

4 DI, AC 90 to 230 V

Digital Output modules

2 DO, DC 24 V, 0.5 A, short-cct-protected, PNP

2 DO, DC 24 V, 2.0 A, short-cct-protected, PNP

2 DO, DC 24 V, 0.5 A, with diagnostics, short-cct-protected, PNP

2 DO, DC 24 V, 2.0 A, with diagnostics, short-cct-protected, PNP

4 DO, DC 24 V, 0.5 A, short-cct-protected, PNP

4 DO, DC 24 V, 0.5 A, 2 connection, short-cct-protected, PNP

4 DO, DC 24 V, 0.5 A, TYPE N, short-cct-protected, NPN

8 DO, DC 24 V, 0.5 A, short-cct-protected, PNP

2 DO, Solid State Relay, AC/DC 230 V, 300 mA

2 DO, AC 125 V, AC 0.5 A, DC 30 V, DC 1 A, isol o/pts, 2 c/o

2 DO, AC 230 V, 1 A, isolated outputs, 2 c/o contacts

2 DO, AC 230 V, DC 30 V, AC/DC 2 A, non-float, 2 make cntcts

2 DO, AC 230 V, DC 30 V, AC/DC 2 A, isol o/pts, 2 make cntcts

8 DO, DC 12 V, 1.0 A

4 DO, AC 230 V, 0.25 A

753-400

753-401

753-410

753-411

753-418

753-421

753-402

753-432

753-403

753-433

753-422

753-408

753-409

753-430

753-431

753-415

753-423

753-428

753-412

753-427

753-406

753-405

753-425

753-424

753-434

753-440

753-501

753-502

753-506

753-507

753-504

753-531

753-516

753-530

753-509

753-514

753-517

753-512

753-513

753-534

753-540

Price Schedule ‘A4’

1 - 37

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Description Cat. No. Price $

2-channel, 0 - 20 mA, Diff.

4-channel, 0 - 20 mA, single ended

2-channel, 0 - 20 mA, single ended

2-channel, 0 - 20 mA, single ended, 16 Bit

2-channel, 0 - 20 mA, Differential inputs

2-channel, 4 - 20 mA, Diff.

4-channel, 4 - 20 mA, single ended

2-channel, 4 - 20 mA, single ended, 16 Bit

2-channel, 4 - 20 mA, single ended

2-channel, 4 - 20 mA, Isolated differential inputs

2-channel, 0 - 1 A AC/DC, Diff.

4-channel, DC 0 - 10 V, single ended

2-channel, DC 0 - 10 V, single ended

2-channel, DC 4 - 20 mA, single ended

2-channel, AC/DC 0 - 10 V, Diff.

2-channel, DC 0 - 10 V, single ended

2-channel, DC ± 10 V, Diff.

4-channel, DC ± 10 V, single ended

2-channel, DC ± 10 V, Diff. measurement input

2-channel, DC ± 10 V, single ended

2-channel, DC 0 - 30 V, Diff. measurement input

2-channel, input module for RTDs, PT100 / RTD

2-channel, t/cpls, open-cct, K type

2-channel, 4-20 mA, HART, up to 4 variables per channel, 12 bit

Analogue Output modules

2-channel, 0 - 20 mA

2-channel, 4 - 20 mA

2-channel, DC 0 - 10 V

4-channel, DC 0 - 10 V

2-channel, DC ± 10 V

4-channel, DC ± 10 V

Speciality modules

Up/Down counter, DC 24 V, 100 kHz

2-channel Up/Down counter, DC 24 V / 16 Bit / 500 Hz

Digital impulse interface

Serial interface RS 232 C

Serial interface RS 485

KNX/TP1, KNX/EIB

System modules

Field Side connection module, DC 0 V

Field Side connection module, DC 24 V

Field Side connection module, AC/DC 0 ...230 V

Connector (required for all 753 Series modules)

Accessories

Coding element Series 753

Refer catalogue WFC2

Price Schedule ‘A4’

753-400

BxH 1)xT (mm) 12x65x100

WAGO I/O-System – 753 SeriesQuick connect modules 2)

Notes: 1) Same size as the 750 series. 2) Please check availability. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP.

Analogue Input modules

753-452

753-453

753-465

753-472

753-480

753-454

753-455

753-474

753-466

753-492

753-475

753-459

753-467

753-466

753-477

753-478

753-456

753-457

753-479

753-476

753-483

753-461

753-469

753-482

753-552

753-554

753-550

753-559

753-556

753-557

753-404

753-638

753-635

753-650

753-653

753-646

753-604

753-603

753-614

753-110

753-150

1 - 38

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

I/O Systems - Dupline® field and installation

bus system

Refer catalogue CDFB-C

Fieldbus Installationbus

®

Dupline is a field- and installation-bus that offers unique solutions for a wide range of applications in building automation, water distribution, energy management, railway systems and many other areas. The system is capable of transmitting multiple digital and analogue signals over several kms, via an ordinary 2-wire cable. Its modular design and simple operating principle enable even novices to implement its use in new or existing applications. Solutions are engineered by combining products from the wide range of Dupline® modules, including digital and analogue I/O modules, PLC and PC interfaces, HMIs and Modems. All modules in an installation connect to the same 2-wire cable which is used to exchange data between modules and between a central controller and modules.

Dupline© is typically used as a remote I/O system, creating a link between field devices, such as sensors, contactors, valves, pushbuttons etc. and a central Monitoring Controller, which may be a PLC, PC or the Dupline® Controller. Dupline® can also be used as a simple wire replacement system where signals are transmitted peer-to-peer without involving a controller or other intelligent unit. The Dupline® signals can be transmitted not only on copper wire, but also on fibre optic cable, via radio modem, on leased telephone lines or via GSM Modem. Dupline® has proven its performance in more than 100,000 installations worldwide since 1986. And even though the latest ASIC technology is used today, the new Dupline® modules are still compatible with those installed 17 years ago.

Parallel wiring of traditional automation systems is often costly and complicated. Each sensor and actuator needs its own wiring, which makes the initial installation cost high. Expansion is also a problem, and even ongoing maintenance costs are high. Therefore, serial bus technology has become an increasingly important part of the concepts of electrical installations for buildings, industrial processes and public services. There are numerous advantages in using a bus system, which replaces a bundle of parallel wires with a single 2-wire cable. Easy and fast installation reduces labor cost significantly, and the possibility of expanding the system using the existing cabling makes it easy to adapt to changing needs. Bus systems also provide cost-effective access to a larger number of signals. This supports the increasing demand for automation systems to collect and use more and more data to optimise cost and performance.

Traditional Installation

Dupline Installation

What is Dupline® ?

Example:Dupline® used as wire replacement system (peer-to-peer)

2 wire cable Dupline (up to 10 km)

I/O Modules

• Digital

• Analogue

I/O Modules

• Digital

• Analogue

Channel Generator

NOT APPROVED FOR SIL3 SAFETY APPLICATIONS

1 - 39

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

I/O Systems - Dupline® field and

installation bus system

Refer catalogue CDFB-C

Fieldbus Installationbus

®

Many criteria have to be considered when selecting a fieldbus system. These include transmission distance capabilities, easy operation, noise immunity, topology and response-time. And cost-effectiveness, of course, is always a factor. Therefore, it is important to define the key application requirements in order to optimise the bus system for the specific task. The strength of the Dupline® system lies in a unique set of features that enable elegant, flexible and cost effective solutions for a wide range of applications.Most of these features originate from the effective time-division multiplex technology used. The efficiency of the protocol allows a low carrier frequency of 1 kHz, providing long transmission distance and superior noise immunity. Hence, Dupline® is capable of transmitting multiple digital and analogue signals over distances up to 10 Km, via a non-shielded, non-twisted 2-wire cable, without using repeaters. These unique Dupline® features provide considerable cost savings in many installations, especially when existing ordinary cables are available for use. Another important Dupline® characteristic is easy handling in all project phases. It does not take an engineering degree to work with Dupline®. No PC is required, since the coding of addresses and testing is carried out by means of simple handheld devices. There is no need for special cables and terminations, and there are no cable

routing restrictions as with many other Fieldbuses. It is so simple and easy to implement, that many customers do their own installation, troubleshooting and maintenance, thus eliminating the need for costly service and installation contracts.Dupline® is system independent and open for interfacing with basically any kind of controller.Serial interfaces with Modbus and dedicated PLC protocols, together with gateways for Profibus-DP and DeviceNet™, enable easy and flexible interfacing to PLCs, PCs and dedicated controllers.

Dupline® features at a glance

Up to 10 km transmission distance without repeaters

Easy handling

Extremely noise immune

Unrestricted topology

Flexible

No special cable requirements

Existing cable can be used

Bus-powered devices available

Flexible interfacing to PLCs and PCs

Transmission via GSM modem, radio modem or fibre optics possible

Proven performance in more than 150,000 installations

Cost-effective

Example:Dupline® used as Remote I/O for PLC

RS 485 / RS 232

Modbus Profibus-DP

DeviceNet

Dupline® # 1

I/O Modules

• Digital

• Analogue

• Counters

Dupline® # 2

I/O Modules

• Digital

• Analogue

• Counters

Interface

Interface

Why use Dupline® ?

NOT APPROVED FOR SIL3 SAFETY APPLICATIONS

1 - 40

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

G50101106

Bus-Powered

single input module

INPUT MODULES

DISPL

AY MODULE

S

G34296470

Analogue inputs

G88104401

Self-powered

light switch

input module

G4420740

Counter module

G34205501

Digital inputs

GAP1605

Handheld

coding unit

ADDRESSCONFIGURATION

VT565W

Touch screen 1)

VT50

Text Display 1)

G54606606

LED status

indicator

G82452574

Temp. display

I/O Systems - Dupline® field and installation

bus system

Refer catalogue CDFB-C

Product categories

The wide range of Dupline® products for industrial applications and building automation can be divided into different categories depending on the function they perform on the network.By combining products from the various categories, complete solutions can be engineered for a multitude of different applications.

Central units

Being the heart of the system, the Dupline® Central Unit produces the carrier signal allowing all the other modules on the network to communicate with each other. There is always one, and only one, central unit in a Dupline® network. Some central units have built-in control and/or interfacing functions.

Digital and Analogue input modules

These modules are used to collect the digital and analogue signals in the field for transmission via Dupline®. They connect to contacts, voltages and analogue signal sources with DIN-norm outputs like 4-20 mA. A Counter module for counting pulses from energy meters is also available.

Digital and Analogue output modules

These modules are used to output signals transmitted on Dupline® to field devices. The digital types are available with relay or transistor outputs and the analogue types have DIN-norm outputs like 4-20 mA. They typically connect to contactors, lamps, instruments, drives etc.

Sensors

Dupline® sensors are self-powered devices that detect or measure physical states directly. The digital types can detect presence of people, magnet proximity, metal proximity or water leakage, while the analogue types measure temperature or light intensity.

Interface products

In many applications, the Dupline® signals need to be controlled and monitored from a central PLC or PC. To accommodate easy and flexible interfacing there are a number of products available for interfacing via serial ports (RS 232 or RS 485) or via standard Fieldbus connections (Profibus-DP and DeviceNet™).

Modems and converters

Sometimes it is necessary to convert the Dupline® signal for transmission on media other than copper wire. Via modems and converters Dupline® can be transmitted on telephone cables, wireless via radio modems, on optical fibre or via GSM modem. The transmission distance on copper wire can be extended by using the Dupline repeater.

NOT APPROVED FOR SIL3 SAFETY APPLICATIONS

Fieldbus Installationbus

®

1 - 41

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Optional Direct Interface to

PLCs and PCs via

• Modbus (RS 232, RS 485)

• Dedicated PLC protocols

• Profibus-DP

• DeviceNet

OUTPUT M

ODULESG88301143

Bus-powered

single relay

output

G34404443

Digital

inputs/outputs

G34485324

Light dimmer

G34396470

Analogue outputs

G38000015

Central unit and interface G34305545

Digital outputs

G34930000

Optical converter

G34910040

Private line modem

MODEMS ANDCONVERTERS

TEST UNIT

D38920000

Repeater

GTU8

Handheld

Bus-powered

test unit

I/O Systems - Dupline® field and

installation bus system

Refer catalogue CDFB-C

Display and HMIs

The products in this category are used to perform the interface between the users and the Dupline® network. The status of digital and analogue signals can be read out on Text Displays, Panel Meters, Touchscreens or LED indicators and control of signals is also possible.

Coding and Testing tools

No PC or other advanced tool is required for address coding of Dupline® modules or for testing an installation. Instead, these tasks are performed by means of two simple handheld devices that are intuitive in use.

NOT APPROVED FOR SIL3 SAFETY APPLICATIONS

Fieldbus Installationbus

®

Notes: 1) GTI50 adaptor required.

1 - 42

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘A7’

I/O Systems - Dupline® field and installation

bus system – Components

Refer catalogue CDFB-C

Channel Generators

G3490

G3800

G3496

NOT APPROVED FOR SIL3 SAFETY APPLICATIONS

Fieldbus Installationbus

®

24 V AC P.S.

115 V AC P.S.

230 V AC P.S.

15-30 V DC P.S.

115-230 V AC P.S.

10-30 V DC P.S.

115-230 V AC P.S.

10-30 V DC P.S.

115-230 V AC P.S.

10-30 V DC P.S.

115-230 V AC P.S.

10-30 V DC P.S.

115-230 V AC P.S.

10-30 V DC P.S.

115-230 V AC P.S.

10-30 V DC P.S.

20-30 V DC P.S.

20-30 V DC P.S.

20-30 V DC P.S.

20-30 V DC P.S.

20-30 V DC P.S.

20-30 V DC P.S.

20-30 V DC P.S.

20-30 V DC P.S.

20-30 V DC P.S.

20-30 V DC P.S.

20-30 V DC P.S.

20-30 V DC P.S.

20-30 V DC P.S.

Standard Channel Generator, up to 128 channels -

selectable

Ch.G. Controller, 4 DI 6-30 V DC, 4 DO PNP <35 V DC,

2 x RS 232 ports

Ch.G. Controller, 4 DI 6-30 V DC, 4 DO PNP <35 V DC,

2 x RS 232 ports, with internal GSM modem. (Antenna &

SIM card required)

Ch.G. Controller, 4 DI 6-30 V DC, 4 DO PNP <35 V DC,

2 x RS 232 ports, with 1 RS 485 port

Ch.G. Controller, 4 DI 6-30 V DC, 4 DO PNP <35 V DC,

2 x RS 232 ports, with internal GSM modem & 1 RS 485

port. (Antenna & SIM card required)

Ch. G. Controller, 4 DI 6-30 V DC, 4 DO PNP <35 V DC,

2 RS 232 ports, 1 RS 485 port, Data Logging

Ch. G. Controller, 4 DI 6-30 V DC, 4 DO PNP <35 V DC,

2 RS 232 ports, 1 RS 485 port, Data Logging, GSM modem,

(Antenna and sim card required)

Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt

protocols for Optolink PLCs

Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt

protocols for LG PLCs

Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt

protocols for G.E.-Fanuc PLCs

Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt

protocols for Mitsubishi FX PLCs

Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt

protocols for Omron PLCs

Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt

protocols for Modbus

Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt

protocols for Allen-Bradley PLCs

Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt

protocols for Schneider PLCs

Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt

protocols for Koyo PLCs

Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt

protocols for Matsushita PLCs

Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt

protocols for Siemens PLCs

Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt

protocols for Toshiba PLCs

Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt

protocols for IDEC PLCs

Description Cat. No. Price $

G34900000024

G34900000115

G34900000230

G34900000824

G38000015230

G38000015800

G38001015230

G38001015800

G38000016230

G38000016800

G38001016230

G38001016800

G38000036230

G38000036800

G38001036230

G38001036800

G34960000700

G34960001700

G34960002700

G34960003700

G34960004700

G34960005700

G34960006700

G34960007700

G34960008700

G34960009700

G34960010700

G34960011700

G34960012700

1 - 43

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

G3891

G3890

G3420

G5010 1106

G4420 7401

G8910 2217

I/O Systems - Dupline® field and

installation bus system – Components

Refer catalogue CDFB-C

Price Schedule ‘A7’

G6110 1145G8910 1101 G8810 4401 G8910 1127 G8910 2116

G8810 1102

G2110 4401

NOT APPROVED FOR SIL3 SAFETY APPLICATIONS

Fieldbus Installationbus

®

Description Cat. No. Price $

Ch. G. Profibus DP slave gateway, 12 Mbaud, 128 I/O, 115-230 V AC P.S.

PNO certified

Ch. G. Profibus DP slave gateway, 12 Mbaud, 128 I/O, 115-230 V AC P.S.

PNO certified, analogue output multiplex

Ch. G. DeviceNet slave gateway, 500 kBaud, 128 I/O 115-230 V AC P.S.

Ch. G. Lonworks gateway, 78 kbps, 128 I/O 115-230 V AC P.S.

Ch. G. Modbus TCP slave gateway, 10/100 Mbit, 128 I/O 115-230 V AC P.S.

Profibus DP slave gateway, 12 Mbaud, 128 I/O, PNO certified 115-230 V AC P.S.

Ch.G., 112 Analink signals, Real time Clock, 1 DO NPN < 35 115-230 V AC P.S.

V DC, Liquid Crystal Display, Printer port, Modbus port 20-30 V DC P.S.

Digital Inputs8 DI, Optoisolated, Contact or NPN 24 V AC P.S.

115 V AC P.S.

230 V AC P.S.

10-30 V AC P.S.

8 DI, Optoisolated, 6-265 V DC/V AC 24 V AC P.S.

115 V AC P.S.

230 V AC P.S.

10-30 V AC P.S.

8 DI, Volt-free Contacts Dupline P.S.

1 DI, Contact, Powered through the network Dupline P.S.

2 DI, Volt-free Contacts Dupline P.S.

4 DI, Counter <14 kHz, non-volatile memory 230 V AC P.S.

15-30 V DC P.S.

1 DI, Inductive proximity switch, M18, cable Dupline P.S.

1 DI, Inductive proximity switch, M18, plug Dupline P.S.

1 DI, Magnetic proximity switch, 11 mm housing Dupline P.S.

1 DI, Magnetic proximity switch, M14 thread Dupline P.S.

4 DI, Universal switch interface Dupline P.S.

Passive Infra-red movement detector Dupline P.S.

2 DI, Water level sensor Dupline P.S.

2 DI, Smoke detector Dupline P.S.

1 DI, 90-265 V AC, for external PIR sensor Dupline P.S.

4 DI, Contact/NPN, Alarm inputs Dupline P.S.

8 DI, Contacts, or NPN, designed for elevator control 10-30 V DC P.S.

8 DI, Voltage, or PNP, designed for elevator control 10-30 V DC P.S.

Channel Generators/Gateways

G38910020230

G38910021230

G38910050230

G38910051230

G38910052230

G38910120230

G38900014230

G38900014800

G34205501024

G34205501115

G34205501230

G34205501800

G34205502024

G34205502115

G34205502230

G34205502800

G34105501

G50101106

G50102206

G44207401230

G44207401724

G61101145

G61101145-1

G89101101

G89101101-G

G88104401

G89101127

G89102116

G89102217

G88101102

G21104401700

G21205501700

G21205502700

1 - 44

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘A4’

I/O Systems - Dupline® field and installation

bus system – Components

Refer catalogue CDFB-C

Digital Outputs

G3430 / G3830

G3430 5545

G3430 4249

G8830 1143

G4248 4134

G3448 5234

NOT APPROVED FOR SIL3 SAFETY APPLICATIONS

Fieldbus Installationbus

®

Description Cat. No. Price $

1 DO, 5 A, SPDT 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 10-30 V DC P.S.2 DO, 5 A, SPDT 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 15-30 V DC P.S.4 DO, 5 A, SPST 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 15-30 V DC P.S.4 DO, Relay 16 A, SPST 24 V AC P.S. 115 V AC P.S. 230 V AC P.S.8 DO, 5 A, SPST 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 15-30 V DC P.S.8 DO, 0.7 A, NPN 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 10-30 V DC P.S.8 DO, 0.7 A, PNP 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 10-30 V DC P.S.8 DO, 16 A/250 V AC, SPST 24 V AC P.S. 115 V AC P.S. 230 V AC P.S.4 DO, 5 A/250 V AC, with interlocking relay 24 V AC P.S.for control of two roller blind motors 115 V AC P.S. 230 V AC P.S. 15-30 V DC P.S.1 DO, 13 A/250 V AC, SPST Dupline P.S.8 DO, 0.1 A, PNP, designed for elevator control 10-30 V DC P.S.8 DO, 0.1 A, PNP, designed for elevator control 10-30 V DC P.S.

Dimmer modules1 Channel, 20-600 Watt, 230 V AC, 6 scenarios/ Dupline P.S., orchoices, -ve, or +ve phase angle dimming 18-30 V DC P.S.1 Channel, 500 Watt, 230 V AC, 4 scenarios/ 230 V AC P.S.choices, -ve, or +ve phase angle dimming 2 Channel, 230 Watt, 230 V AC, 4 scenarios/choices 230 V AC P.S.2 Channel, 1-10 V for adjustable ballasts4 Lighting scenarios per channel

G34301149024

G34301149115

G34301149230

G34301149800

G34302249024

G34302249115

G34302249230

G34302249824

G34304443024

G34304443115

G34304443230

G34304443824

G34304445024

G34304445115

G34304445230

G38305543024

G38305543115

G38305543230

G38305543824

G34305511024

G34305511115

G34305511230

G34305511800

G34305521024

G34305521115

G34305521230

G34305521800

G34305545024

G34305545115

G34305545230

G34304249024

G34304249115

G34304249230

G34304249824

G88301143

G21305521700

G21305511700

G42484134724

G34485134230

G34485234230

G34485238230

1 - 45

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Refer catalogue CDFB-C

Price Schedule ‘A7’

Fieldbus Installationbus

®

I/O Systems - Dupline® field and

installation bus system – Components

Irrigation control with Dupline®

By running the power, valve control signals and pulses from flow meters on a single two-wire cable, Dupline reduces the wiring and cable cost significantly and makes expansion easy. Any type of irrigation controller, whether it is a PLC, PC or dedicated controller, can use Dupline as a remote I/O system.In order to achieve sufficient voltage level to switch the 3-wire latching valves in the field, a Booster module converts the Dupline voltage level to 28 V DC. Each valve is connected to an I/O-module with two outputs for opening and closing the valve, and with 2 inputs that can be used for transmission of pulses from flow meters. The module is available in a housing that allows underground installation, and in a DIN-rail mount housing. Each time the valve is fired, a built-in capacitor slowly charges up and after 10s it stores enough energy for the next valve operation. The wiring topology is unrestricted with no limitation in number and length of branches. One Hi-Line network can handle up to 64 valves over distances up to 7 km, and several networks can be linked together.

Digital Mixed I/O

G3440 4443

GH3440 4412

GH6440 4412

G8210

G8510

G8110

Up to 7 Kilometres!

PLC (optional) Channel

generator Valve module

Hi-Line

converter

NOT APPROVED FOR SIL3 SAFETY APPLICATIONS

Description Cat. No. Price $

2 DI, 2 DO, Combined I/O module, 2 x 6-265 V AC/DC 24 V AC P.S.optoisolated inputs and 2 SPST relay outputs 115 V AC P.S. 230 V AC P.S. 15-30 V DC P.S.2 outputs for control of 3 wire 12 V DC latching valve Highline P.S.and 2 contact inputs GH348500002 outputs for control of 3 wire 12 V DC latching valve Highline P.S.and 2 contact inputs GH348500004 DI light switch with 4 DO LED indicators, grey Dupline P.S.4 DI light switch with 4 DO LED indicators, grey Dupline P.S.4 DI light switch with 4 DO LED indicators, white Dupline P.S.1 light switch with 1 LED indicator Dupline P.S.2 light switches with 2 LED indicators Dupline P.S.3 light switches with 3 LED indicators Dupline P.S.4 wireless light switches, 4 LED indicators, OPUS, white CR2023 Battery4 wireless light switches, 4 LED indicators, FUGA, white CR2023 Battery4 DI, Volt-free Contact, 4 DO, 1.5 mA, PNP, for light switches Dupline P.S.2 DI, Volt-free Contact, 2 DO, 200 mA, PNP, for elevators 10-30 V DC P.S.2 DI, Volt-free Contact, 2 DO, 200 mA, NPN, for elevators 10-30 V DC P.S.4 DI, Volt-free Contact, 4 DO, 200 mA, PNP, for elevators 10-30 V DC P.S.4 DI, Volt-free Contact, 4 DO, 200 mA, NPN, for elevators 10-30 V DC P.S.Room temperature controller, LC display, OPUS, white Dupline P.S.Room temperature controller, LC display, FUGA, white Dupline P.S.

G34404443024

G34404443115

G34404443230

G34404443824

GH34404412

GH64404412

G81104406

G81104407

G82104406

G85101101

G85102201

G85103301

G82864406703

G81864407703

G88405521

G21404422700

G21404421700

G21405520700

G21405510700

G82452574

G81452574

1 - 46

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Description Cat. No. Price $

4 AI, isolated, 0 - 20 mA, 4-20 mA, 0-10 V DC, 24 V AC P.S.

configurable, Analink, Multiplexed BCD, 8-bit selectable 115 V AC P.S.

230 V AC P.S.

10-30 V DC P.S.

1 AI, 4-20 mA, Analink 8-bit protocol Dupline P.S.

1 AI, PT100 RTD, 3-wire input, -50 °C to +40 °C Dupline P.S.

1 AI, PT100 RTD, 3-wire input, +30 °C to +120 °C Dupline P.S.

1 AI, PT100 RTD, 3-wire input, -10 °C to +100 °C Dupline P.S.

1 AI, Built in PT1000, +10 °C to +35 °C Dupline P.S.2 AI, built in Temperature and Humidity sensors, Dupline P.S.0 °C to 50 °C, 5 to 95 % RH

1 AI, Light intensity sensor, 0.1 to 100,000 lux Dupline P.S.

1 AI, Temperature sensor, indoor, -30 °C to +60 °C Dupline P.S.

1 AI, Temperature sensor, IP 67, -30 °C to +60 °C Dupline P.S.

1 AO, 0-10 V DC, 8 bit resolution 230 V AC P.S.

4 AO, isolated, 0-20 mA, 4 - 20 mA, 0-10 V DC, 24 V AC P.S.

configurable, Analink, Multiplexed BCD, 8-bit selectable 115 V AC P.S.

230 V AC P.S.

10-30 V DC P.S.

Thermostat, with built-in temp. sensor, -20 °C to +70 °C Dupline P.S.

ConvertersLandline modem, Digital 8-bit analogue, 24 V AC P.S.

non-multiplexed 3 1/2 digit BCD 115 V AC P.S.

230 V AC P.S.

Optical to Electrical, converting optical to Dupline 230 V AC P.S.

Electrical to Optical, converting Dupline to optical 230 V AC P.S.

Dupline to Highline converter, 28 V DC irrigation 20-30 V DC

Dupline to signal repeater for signals beyond 10 km 24 V AC P.S.

Dupline to signal repeater for signals beyond 10 km 115 V AC P.S.

Dupline to signal repeater for signals beyond 10 km 230 V AC P.S.

Dupline to Wireless signals @ 868MHz, up to 100 meters 230 V AC P.S.

Interface between ESA Text and Touch screens and Powered by

Dupline channel generators with Modbus RS 485 ports RS 485 port

Interface between Carlo Gavazzi EM4 and WM22 energy Dupline P.S.

meters and Dupline

Optolink interface, Reads up to 63 Dupline systems 24 V AC P.S.

networked through optolinks (G34910000). 115 V AC P.S.

Operates with G34910090. 230 V AC P.S.

Optolink interface, Links a PC, or a PLC that has an 24 V AC P.S.

RS 232 serial port with a fibre optic Lan-ring. 115 V AC P.S.

Operates with G34910000 230 V AC P.S.

Ethernet to RS 232 converter, 1 port, 10/100, TCP/IP 12 - 48 V DC

Ethernet to RS 232 converter, 2 port, 10/100, TCP/IP 12 - 48 V DC

Price Schedule ‘A7’

Refer catalogue CDFB-C

Fieldbus Installationbus

®

G3210 1111

I/O Systems - Dupline® field and

installation bus system – Components

Analogue modules

G3429 6470

G3210 1161

G4311 1120

G8611 1010

G8911 1010

G3439 6470

NOT APPROVED FOR SIL3 SAFETY APPLICATIONS

G34910040024

G34910040115

G34910040230

G34920000230

G34930000230

GH34850000724

D38920000024

D38920000115

D38920000230

G34860058230

GTI50

G63910240

G34910000024

G34910000115

G34910000230

G34910090024

G34910090115

G34910090230

ETHCONV2

ETHCONV3

G34296470024

G34296470115

G34296470230

G34296470800

G32101161

G32101111

G32101112

G32101113

G81112211

G81113315

G43111120

G86111010

G89111010

G32385138230

G34396470024

G34396470115

G34396470230

G34396470800

G81103394

1 - 47

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

I/O Systems - Dupline® field and

installation bus system – Components

Refer catalogue CDFB-C

Price Schedule ‘A7’

Displays / HMI

GTU8

D6369 6475

G5460 6606

G4185 5530DUPDATACC

GAP1605

NOT APPROVED FOR SIL3 SAFETY APPLICATIONS

Fieldbus Installationbus

®

ADAPT1605DT01

G4085 5562

Description Cat. No. Price $

LED, 4 x 7 segment BCD digits for display of 8-bit analogue 24 V AC P.S.values, with 4 digital outputs 230 V AC P.S.16 channel LED status indicator, panel mounting 24 V AC P.S. 115 V AC P.S. 230 V AC P.S.Note: Many types of ESA text and touch screens are compatible with Dupline using the Dupline GTI50 interface.

Remote controls

Infra-red remote control hand-held transmitter for 9 Volt batterycontrol of lighting, dimming, roller blinds etc... Must be paired with G4185 5531 Infra-Red remote receiver, wall mounted. Dupline P.S.Must be paired with G4085 5562

Programming / testing

Coding device for assigning addresses to Dupline I/O 9 V DC batterymodules and sensorsTest unit for monitoring and control of Dupline channels. 9 V DC batteryNot to be used for Hi-Line installions. Test unit for monitoring and control of Hi-Line channels. 9 V DC batteryNot to be used for Dupline installations. Coding adaptor between GAP1605 and Dupline modules without a standard connection. Includes an M12 plug for modules like G89111010. Accessories

Power supply, Boosts power to some Dupline modules 15 - 30 V DC P.S. through a third wire DC-bus. Up to 4 ampere @ 25 °CGSM antenna, 900 MHz for G3800xxxx Ch. generators Synchronizer for analogue modules, max of 112 signals Dupline P.S.Cable termination unit for standard Dupline Cable termination unit for Hi-line

Software

Software, DDE and ActiveX drivers for G3800 series channel generators and interfaces. Copies and pastes dynamic Dupline links into Excel spreadsheets.Software, Dupline-Online One License for data logging, visualization and alarm handling for G3800xx36 series channel generatorsSoftware, ADD-License to Dupline-Online for data logging, visualization and alarm handling for G3800xx36 series channel generators

D63696475024

D63696475230

G54606606024

G54606606115

G54606606230

G40855562

G41855531

GAP1605

GTU8

GHTU8

ADAPT1605

G34850000

ANT1

D32124000

DT01

DT02

DUPDATACC

DUPSERVSW

DUPSERVADD

1 - 48

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Operator panels and touch screens

SC207

Allen-Bradley (ETH), MicroLogix, DF1 Delta DVP Hitachi Mitsubishi A-Fx-Fx2 Modbus RTU Master and Slave Modbus TCP Master and Slave (ETH)

Omron Host Link, CJ1-CS1-CP1, CS1-CJ1 (ETH) Panasonic FP-Sigma series (RS 232),

FP series (ETH) Schneider Twido-Zelio-Unitelway, Premium

(ETH) Siemens S5, S7-200 PPI, S7 300/400 (ETH),

7” Wide 65.536 colors tft 800 X 480 resolution White LED backlighting RS232/RS485 (Integrated MPI) Ethernet USB host and sevice SD/MMC Slot

Features

SC207 Drivers available

Display SC207

Technology 7” LCD Graphic TFT 65.536 colours

Touch screen Analogue

Backlighting White LED

Minimum lamp life at 25° C

50,000 hours

Resolution 800 x 480 pixel

Terminal

Processor Intel PXA 270

CPU Clock 520 MHz

RAM 64 MB

Flash 32 MB

Interfaces

Serial port SP1 (RS232/485/MPI)

USB Host port 1 x v 1.1

USB Device port 1 x v 1.1

Card Bus Slot Secure Digital/MMC

Network Ethernet 10/100 Mbit - RJ45

Dimensions

External (W x H x D) (mm)

202 x 142 x 40

Bore holes (W x H) (mm)

194 x 134

Technical specifications

Chassis Plastic ABS

Power supply 18...32 Vcc

Power consumption ~ 8 W (24 V DC)

Hardware clock Supercapacitor 72h

Working temperature 0...+50 °C

Storage/transport temperature

-20...+60 °C

Humidity 85% (non-condensing)

Weight ~ 1,6 Kg

Protection level IP 65 front

Certification CE

Description Cat. No.

7" widescreen 65k colours TFT, Port: SP1, Ethernet, USB:Host device, SD/MMC slot

SC207A0101

1 - 49

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Operator panels and touch screens

- System Overview

Dual serial ports allow simultaneous communications to different front-end devices, while pipelining expands the functionality of the panel into a gateway by providing bi-directional data transfer between disparate devices. Alarms, reports and mimic pages can be sent directly to a parallel printer by panels fitted with an on-board centronics port.

Fast and easy configuration Extensive product range Large displays - up to 12.1” IP 65 protection lever (front)

Serial and network communications

ESANet

ESANet is a high-speed network that allows both the text and graphical panels to communicate and share data with each other. Up to 32 ESA panels can be configured in a client server archi tecture. Server panels connect to I/O devices such as a PLC, while clients use variables and memory areas exported by the server. Using one of the standard serial ports on each panel, units can be linked together to provide remote monitoring and control from all areas of the factory or process.

Communication drivers

The VT range of panels will directly communicate with an extensive range of I/O devices including PLCs and drives. Standard interfaces include: ABB, Allen Bradley, Crouzet, GE-Fanuc, Hitachi, Idec, Izumi, Keyence, Klockner Moeller, LG, Matsushita / NAIS, NHP Microlink, Mitsubishi, Modicon, Omron, SAIA, Siemens, Sprecher + Schuh, Telemecanique, Toshiba.

PC (programming)

MSP

ASP

CONTROL NETWORK

ESANET (32 UNITS – Available on all the panels)

LPT

PC (programming)

Drives

ASP RS 232/RS 485

LPT

VT 170 W / VT 190 W / VT 300 W

VT 310 W / VT 320 W / VT 330 W

VT 555 W / VT 565 W / VT 575 W

VT 585 W / VT 595 W

PLCs

MSP RS 232

RS 422/485/TTY

Printer

(not VT 170 W)

1 - 50

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Refer publications VT50, VT170

Notes: 1) Multi serial port (25 pin). 2) Auxiliary serial port (15 pin). 3) XCSF85C power supplies are on Price Schedule ‘A2’. 4) NETT price only.

Operator panels and touch screensText based operator panels

The ESA range of text and graphic operator panels comprises three groups of models – text panels, graphical touch panels and graphical touch screens. Each model, with its own array of features, is targeted towards specific applications and user requirements.

Flexible serial and network connectivity

One software package for all models

Robust die-cast construction

Full range of interface drivers

Fast and easy configuration

Extensive product range

Large displays - up to 12.1”

IP 65 protection level (front)

Text operator panelsThe compact range of text only displays is ideal for machine control in small to medium sized applications. With bright LCD back-lit displays available in either a 2 x 20 character or 4 x 20 character configuration and an optional printer port, these text displays offer extreme flexibility at a cost price.

Thanks to the availability of a large number of serial protocols, these terminals can be connected to PLCs, variable speed drives, thermoregulators and other serial devices.

Text operator panels (dimensions in mm)

Ordering details

RVT5009

VTBUTTONCELL

PCNET

VT5ESABUS

VTPROFI/DP

XCSP85C

VTWINLITE

Accessories

Mounting brackets and screws, rubber gasket, phoenix connector

(VT 050, VT 060)

Lithium 3 V battery back-up recipe and clock

External gateway to connect a PC (SCADA, MS Excel, MS Access,

Internet Explorer, etc.) to any PLC or ESA operator panel

RS 485 module to connect the terminal in an ESANET Network

(to use the VT 170 WA / VT 190 WA in a server configuration)

External module PROFIBUS / DP

External 24 V DC 3.5 A Power supply 3)

Programme CD software and cable 4)

VT 170WA

VT 190W A

VT050

VT060

VT150W

VT150W DP

VT160W

VT160W DP

VT170W A

VT190W A

VT190W AP

Cat. No.Description

Text, LCD, 2 x 20, Dim. 166 x 86 x 41, MSP 1)

Text, LCD, 4 x 20, Dim. 166 x 86 x 41, MSP 1)

Text, LCD, 4 x 20, Dim. 148 x 188 x 41, MSP 1)

Text, LCD, 4 x 20, Dim. 148 x 188 x 41, MSP 1), PROFIBUS DP

Text, LCD, 4 x 20, Dim. 296 x 188 x 42, MSP 1)

Text, LCD, 4 x 20, Dim. 296 x 188 x 42, MSP 1), PROFIBUS DP

Text, LCD, 4 x 20, Dim. 126 x 196 x 60, MSP 1), ASP 2)

Text, LCD, 4 x 40, Dim. 252 x 196 x 60, MSP 1), ASP 2)

Text, LCD, 4 x 40, Dim. 252 x 196 x 60, MSP 1), ASP 2), LPT

Price $

VT 050

Price Schedule ‘A4’

1 - 51

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Refer publications VT32-F Operator panels and touch screens

Graphics operator panels

This range of graphic based touch panels is ideal for replacing pushbuttons, indicating lights, analogue meters and much more. Starting at the compact 5” display the units are available in colour or monochrome, STN or TFT graphics. Dual serial ports, optional printer port, trending, recipe management and lifelike graphics make these units ideal for any size applications.Easy to configure and simple to use. Thanks to the availability of a large number of serial protocols, these terminals can be connected to PLCs, variable speed drives, thermoregulators and other serial devices.

Ordering details Graphic operator panels (dimensions in mm)

VT 310W A

VT 320W A

VT 330W APM

VTBUTTONCELL

PCNET

VTPROFI/DP

XCSP85C

VTWINLITE

Accessories

Lithium 3 V battery back-up recipe and clock

External gateway to connect a PC (SCADA, MS Excel, MS Access,

Internet Explorer, etc.) to any PLC or ESA operator panel

External module PROFIBUS / DP

External 24 V DC, 3.5 A Power supply 3)

Programme CD software and cable 4)

Cat. No. Price $

Price Schedule ‘A4’

Notes: 1) Multi serial port (25 pin). 2) Auxiliary serial port (15 pin). 3) XCSF85C power supplies are on Price Schedule ‘A2’. 4) NETT price only.

VT300W A

VT300W AP

VT310W A

VT310W AP

VT320W A

VT320W AP

VT330W APM

VT330W APT

Cat. No.

Graphic, Monochrome STN, Res 240 x 64,

Dim. 252 x 196 x 60, MSP 1), ASP 2)

Graphic, Monochrome STN, Res 240 x 64,

Dim. 252 x 196 x 60, MSP 1), ASP 2), LPT

Graphic 5.5” screen, Monochrome STN, Res 240 x 128,

Dim. 252 x 196 x 60, MSP 1), ASP 2)

Graphic 5.5” screen, Monochrome STN, Res 240 x 128,

Dim. 252 x 196 x 60, MSP 1), ASP 2), LPT

Graphic 5.7” screen, Colour STN, Res 320 x 240,

Dim. 305 x 196 x 60, MSP 1), ASP 2)

Graphic 5.7” screen, Colour STN, Res 320 x 240,

Dim 305 x 196 x 60, MSP 1), ASP 2), LPT

Graphic 10.4” screen, Monochrome STN, Res 640 x 480,

Dim 435 x 260 x 74, MSP 1), ASP 2), LPT

Graphic 10.4” screen, Colour TFT, Res 640 x 480,

Dim 435 x 260 x 74, MSP 1), ASP 2), LPT

Description Price $

1 - 52

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

VT 555W

This range of graphic based touch screens is ideal for replacing pushbuttons, indicating lights, analogue meters and much more. With a large display of up to 10.4”, the units are available in colour or monochrome, STN or TFT graphics. Dual serial ports, optional printer port, trending, recipe management and lifelike graphics make these units ideal for any size applications.Easy to configure and simple to use. Thanks to the availability of a large number of serial protocols, these terminals can be connected to PLCs, variable speed drives, thermoregulators and other serial devices.

Ordering details Graphic touch screens (dimensions in mm)

VT 505W

VT 155W

VT 505H

Operator panels and touch screensGraphics touch screens

VT 525W

VT 515W

Price Schedule ‘A4’

Refer publications VT155-F, VT525-F,

VT555-F

Notes: 1) Multi Serial Port (25 pin). 2) Auxiliary Serial Port (8 pin). 3) Auxiliary Serial Port (15 pin).

VT 185W

Graphic 4" screen, 4 Tones of grey LCD, Res 240 x 128, Dim 166 x 100 x 40, MSP 1), ASP-8 2), Project: 640 KB - Recipes: 16 KBGraphic 4" screen, 4 Tones of grey LCD, Res 240 x 128, Dim 166 x 100 x 40, ASP-8 2), Project: 640 KB - Recipes: 16 KB, Profibus DPGraphic 4" screen, 4 Tones of grey LCD, Res 240 x 128, Dim 166 x 100 x 40, ASP-8 2), Project: 640 KB - Recipes: 16 KB, Ethernet 10/100Graphic 3.6" screen, 16 Colour TFT, Res 320 x 240, Dim 166 x 100 x 40, MSP 1), ASP-8 2), Project: 960 KB - Recipes: 32 KBGraphic 3.6" screen, 16 Colour TFT, Res 320 x 240, Dim 166 x 100 x 40, ASP-8 2), Project: 960 KB - Recipes: 32 KB, Ethernet 10/100Graphic 5.5" screen, Monochrome STN, Res 240 x 128, Dim 210 x 158 x 54, MSP 1), ASP 3), 512 KB - Recipes: 128 KB, Ethernet 10/100Graphic 5.5" screen, Monochrome STN, Res 240 x 128, Dim 210 x 158 x 54, MSP 1), ASP 3), LPT, 512 KB - Recipes: 128 KBGraphic 5.5" screen, Monochrome STN, Res 240 x 128, Dim 210 x 158 x 54, MSP 1), LPT, 512 KB - Recipes: 128 KB, Profibus DPGraphic 5.7" screen, 4 level blue STN, Res 320 x 240, Dim 210 x 158 x 54, MSP 1), Project: 640 KB - Recipes: 16 KBGraphic 5.7" screen, 4 level blue STN, Res 320 x 240, Dim 210 x 158 x 54, MSP 1), Project: 640 KB - Recipes: 16 KB, Profibus DPGraphic 5.7" screen, 4 level blue STN, Res 320 x 240, Dim 210 x 158 x 54, ASP-8 2), Project: 640 KB - Recipes: 16 KB, Ethernet 10/100Hand held Graphic 5.7" screen, 4 level blue STN, Res 320 x 240, 10 function keys, 2 push buttons, optional MSP 1) if VTHCB adaptor fitted, Project: 640 KB - Recipes: 16 KBGraphic 5.7" screen, 4 level blue STN, Res 320 x 240, Dim 210 x 158 x 54, MSP 1), Project: 640 KB - Recipes: 16 KB, 8 KB Memory Alarms, capacitor back-upGraphic 5.7" screen, 4 level blue STN, Res 320 x 240, Dim 210 x 158 x 54, MSP 1), Project: 640 KB - Recipes: 16 KB, 8 KB Memory Alarms, Capacitor back-up, Profibus DPGraphic 5.7" screen, 4 level blue STN, Res 320 x 240, Dim 210 x 158 x 54, ASP-8 2), Project: 640 KB - Recipes: 16 KB, 8 KB Memory Alarms, Capacitor back-up, Ethernet 10/100Graphic 5.7" screen, 16 Colour STN, Res 320 x 240, Dim 210 x 158 x 54, MSP 1), ASP-8 2), Project: 960 KB - Recipes: 32 KBGraphic 5.7" screen, 16 Colour STN, Res 320 x 240, Dim 210 x 158 x 54, ASP-8 2), Project: 960 KB - Recipes: 32 KB, Profibus DPGraphic 5.7" screen, 16 Colour STN, Res 320 x 240, Dim 210 x 158 x 54, ASP-8 2), Project: 960 KB - Recipes: 32 KB, Ethernet 10/100Hand held Graphic 5.7" screen, 16 Colour STN, Res 320 x 240, 10 function keys, 2 push buttons, optional MSP 1) and ASP-8 2) if VTHCB fitted, Project: 960 KB - Recipes: 32 KB

VT155W

VT155W 000DP

VT155W 000ET

VT185W

VT185W 000ET

VT555W A

VT555W AP

VT555W AP0DP

VT505W

VT505W DP

VT505W 000ET

VT505H

VT515W

VT515W 000DP

VT515W 000ET

VT525W

VT525W 000DP

VT525W 000ET

VT525H

Cat. No.Description Price $

1 - 53

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Refer publications VT575-F, VT595-F,

VT 560W

VT 565W

VT 575W

VT 580W

VT 585W

VT 595W

Ordering details Graphic touch screens (dimensions in mm)

Operator panels and touch screens

Graphics touch screens

VT560W A

VT560W A0M

VT565W A

VT565W AP

VT565W A0M

VT565W APM

VT580W APT

VT580W 0PTDP

VT580W 0PTET

VT585W BPT

VT585W BPTDP

VT585W BPTET

VT595W APT

VT595W 0PTDP

VT595W 0PTET

Cat. No.

Graphic 5.7" screen, 16 Colours STN, Res 320 x 240, Dim 210 x 158 x 61,

MSP 1), ASP 2), Project: 1 MB - Recipes: 128 KB, Battery back-up

Graphic 5.7" screen, 8 tones of blue STN, Res 320 x 240, Dim 210 x 158 x 61,

MSP 1), ASP 2), Project: 1 MB - Recipes: 128 KB, Battery back-up

Graphic 5.7" screen, Colour STN, Res 320 x 240,

Dim 210 x 158 x 54, MSP 1), ASP 2)

Graphic 5.7" screen, Colour STN, Res 320 x 240,

Dim 210 x 158 x 54, MSP 1), ASP 2), LPT,

Graphic 5.7" screen, Monochrome STN, Res 320 x 240,

Dim 210 x 158 x 54, MSP 1), ASP 2)

Graphic 5.7" screen, Monochrome STN, Res 320 x 240,

Dim 210 x 158 x 54, MSP 1), ASP 2), LPT,

Graphic 8.4" screen, 256 Colours TFT, Res 800 x 600, Dim 246 x 189 x 38,

MSP 1), ASP 2), LPT, Project: 7 MB - Recipes: 192 KB

Graphic 8.4" screen, 256 Colours TFT, Res 800 x 600, Dim 246 x 189 x 38,

MSP 1), LPT, Project: 7 MB - Recipes: 192 KB, Profibus DP

Graphic 8.4" screen, 256 Colours TFT, Res 800 x 600, Dim 246 x 189 x 38,

MSP 1), LPT, Project: 7 MB - Recipes: 192 KB, Ethernet 10/100

Graphic 10.4" screen, Colour TFT, Res 640 x 480, Dim 336 x 256 x 44,

MSP 1), ASP 2), LPT, Project: 7 MB - Recipes: 128 KB

Graphic 10.4" screen, Colour TFT, Res 640 x 480, Dim 336 x 256 x 44,

MSP 1), LPT, Project: 7 MB - Recipes: 128 KB, Profibus DP

Graphic 10.4" screen, Colour TFT, Res 640 x 480, Dim 336 x 256 x 44,

MSP 1), LPT, Project: 7 MB - Recipes: 128 KB, Ethernet 10/100

Graphic 12.1" screen, 256 Colour TFT, Res 800 x 600, Dim 336 x 256 x 44,

MSP 1), ASP 2), LPT, Project: 7 MB - Recipes: 128 KB

Graphic 12.1" screen, 256 Colour TFT, Res 800 x 600, Dim 336 x 256 x 44,

MSP 1), LPT, Project: 7 MB - Recipes: 128 KB, Profibus DP

Graphic 12.1" screen, 256 Colour TFT, Res 800 x 600, Dim 336 x 256 x 44,

MSP 1), LPT, Project: 7 MB - Recipes: 128 KB, Ethernet 10/100

Description Price $

Price Schedule ‘A4’

Notes: 1) Multi Serial Port (25 pin). 2) Auxiliary Serial Port (15 pin).

1 - 54

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Accessories

VTBUTTONCELL

PROTFILM6

PROTFILM10

PROTFILM12

PCNET

VTPROFI/DP

XCSP85C

VTWINLITE

Lithium 3 V battery back-up recipe and clock

Transparent adhesive protection film for 6” touch screen

(VT505W, VT525W, VT555W, VT565W) 5 sheets included

Transparent adhesive protection film for 10” touch screen

(VT585W) 5 sheets included

Transparent adhesive protection film for 12” touch screen (VT595W)

5 sheets included

External gateway to connect a PC (SCADA, MS Excel, MS Access,

Internet Explorer, etc.) to any PLC or ESA operator panel

External module PROFIBUS / DP

External 24 V DC 3.5 A Power supply 2)

Programme CD software and cable 3)

Notes: 1) All cables are 2 m in length. 2) XCSF85C power supplies are on Price Schedule ‘A2’. 3) NETT price only.

Operator panels and touch screensCommunication cables

Price Schedule ‘A4’

Download cable from PC to ESA displays

ESA MINI DIN download adaptor

Communications cable between the 9 pin ASP port

(VT 170 / VT 190 ) and the Hitachi H Board,

H 200 / H 250 / H 252 B / H 252 C PLCs

(Can also be used to program the above PLCs)

Communications cable between the 25 pin MSP port (all ESA panels)

and the Hitachi H Board, H 200 / H 250 / H 252 B / H 252 C PLCs

Communications cable between the 9 pin ASP (VT 170 / VT 190 )

and the Hitachi EH-150 PLC

(Can also be used to program the EH-150 PLC)

Communications cable between the 25 pin MSP port (all ESA panels)

and the Hitachi EH-150 PLC

VTCBLXFR 1)

VTCBLADP 1)

CBL90H 1)

VTCBL2515 1)

CBL1509 1)

VTCBL2545 1)

Description Cat. No. Price $

1 - 55

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Operator panels and touch screens

VTWIN Configuration software

One software package for the entire rangeAll graphic and text based panels are configured with one package - VTWIN. VTWIN is the Microsoft Windows® based software for configuring your operator panel. The software supports Windows 95, Windows 98, Windows NT 4.0, Windows 2000 and Windows XP. It is intuitive, easy to use and includes a graphics editor for developing professional looking screens with a minimum of fuss. The software comes packaged with all available communication drivers and a cable for communication between a PC and the panel. On-line help and the ability to import bitmap images make configuration quick and easy, saving both time and money.

Use the same software development environment to configure all of the operator units, whether it is the low-end text based panels or the high-end graphics based touch panels. Application programs previously created for one particular model can be re-used for any model in the range. This means you only need to learn one software package and importantly, you only need to purchase one software package.

VTWIN features Rapid application development – a wide variety of pre-configured picture elements can be inserted

into a page – multi-language labels and texts, dynamic text fields, lines, rectangles, ellipses, arcs, bar graphs, touch buttons, bitmap images, information messages, alarms, etc

Graphic image formats – directly import graphic images from a wide selection of standard formats e.g. BMP, JPG, GIF, DXF, PSD, TIFF, WMF and many more

3-D Graphics – create life-like 3-D graphic pictures with image compression, stretching, dithering and support for 256 colours

Alarm thresholds – specify alarm thresholds on objects making it possible to dynamically change colours based on the related process variable

Advanced graphics functions – represent analogue values using analogue indicators, selector knobs, potentiometers and sliders

With the WYSIWYG graphics editor you know exactly

how your text and graphics will appear on the VT

terminal before you download the project.

To gain access to PLC data simply assign a variable

name and the required PLC register.

1 - 56

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Operator panels and touch screensDimensions and cut-outs (mm)

Text and Graphic panels

305

196

560

291275

120

28

28

176186

8 137.5 137.5

ø 4.5

VT 320W

13927

86

166

95

41

77

157

VT 50/ VT 60 VT 190W

435

260

5

74

418.3403

240 130249

4.5

49 49

ø 5

7.6

152.5 152.5

55

55

VT 330W

VT 170W

252

196

5

60

242232

29

120178

29

116116

5

186

4.5

1 - 57

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Operator panels and touch screensDimensions and cut-outs (mm)

VT 505W/VT 555W/VT 565W

VT 155W / VT 185

VT 595W

VT 575W / VT 580

VT 585W

Touch Operator panels

AC-ADROIT-SCADA HMI

WORLD CLASS SCADA / HMI SOFTWARE

0800 NHP NHP nhp-nz.com1300 NHP NHP nhp.com.au

AUTOMATION SYSTEMS

PLCs Smart UI (web enabled)

Classic UI

RTUs

DatabasesMES

OPC Client

API

OPC Server

Databases

Web ServicesWeb Services

1 - 59

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Visualisation and reporting softwareWorld class 32 bit

SCADA / HMI software

Open automation technology

Adroit is a technologically advanced 32 bit SCADA (Supervisory Control and Data Acquisition) system designed for process control, manufacturing systems and open automation applications Developed specifically for Windows 2000, XP, and 2003 Server, Adroit has a flexible object-oriented client server architecture that supports from a standalone implementation to an installation spanning multiple sites.

Adroit Client Adroit Client

Ethernet/ICP/IP

Control Network

Active Cluster

Hot Stand-By

Adroit

SCADA

Server

Adroit

SCADA

ServerAdroit

SCADA

Server

Modem

Internet

Remote

Adroit Client

Distributed multi-client multi-server configuration in a large network system with several servers and several clients, each running on separate Windows 32 bit operating system.

Programmable logic controllers (PLCs), databases, remote terminal units (RTUs), OPC servers

• On-line configuration• No separate development system• Mimic replay• Template mimics and trends

• Scalable open server architecture• Integrated Visual Basic scripting• Wide area network support• SQL database connectivity

Microsoft®

Technologies

Outstanding features

Alarm ManagementSMS Handling SystemSystem Auditing

Plant VCR - replay historical data using mimics Database connectivity - connect to any third-party ODBC

and OLE DB database Active clusters - Adroit’s elegant answer to Hot stand-by

and Server redundancy Web client - view plant data from anywhere in the world Visual basic and java scripting - built-in

scripts require no proprietary code OPC client and server 150 + native drivers

1 - 60

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Visualisation and reporting softwareWorld class 32 bit

SCADA / HMI software

Server Redundancy with Active clusters

Very few commercial off-the-shelf SCADA HMI products offer genuine hot-standby redundancy, whereby a computer running the real-time, tag database, can suffer catastrophic hardware or software failure without causing loss of data or operator control and monitoring capability. Now with the release of Adroit with its Active Clustering technology this most demanding of all requirements is now achievable.

The above diagram shows 5 Adroit workstations, 2 Adroit servers, and some PLCs connected in a typical client-server, hot-standby configuration. To achieve 100 % redundancy and bumpless switch-over of workstations from a failed server to a standby server, both servers need to be running exactly the same tag database. Server I/O options allow for replicated scanning in and/or out, when in standby mode. Alternatively, if the PLC or other front-end device does not support more than one port, or, as is often the case, PLC communications bandwidth is the critical system bottleneck, then automatic shadowing of plant I/O will occur.

Open Interfaces and Drivers

Adroit has a comprehensive range of drivers for all major controllers and networks including:

More than 150 drivers available…visit www.nhp.com.au/p_automation_communication.asp for complete driver list.

OPC Client and Server

DNP3

Hitachi

Siemens

Allen Bradley

Modbus

Omron

Mitsubishi

Texas Instruments

ABB

Toshiba

Microlink

Opto 22

Samsung

Yokogawa

Applicom

Moore

Eagle

Lonworks

Gem 80

Motorola

Square D

Klockner Moeller

1 - 61

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Visualisation and reporting softwareWorld class 32 bit

SCADA / HMI software

DB connectivity

OLE DB has been brought into Adroit to give tight, bi-directional data transfer of both real-time and historical data between Adroit and third-party databases. These databases may exist locally or remotely on a LAN/WAN. Data transfer will execute on data change and/or at configurable time intervals. The nice thing about the Adroit DB connectivity is that Adroit will act as a database client. Third-party gateway software applications are no longer needed.The dbAccess agent also support ODBC allowing values to be written to or read from any ODBC source including CSV files.Both OLE DB and ODBC allow values to be appended, deleted, updated or retrieved.

Scripting

Scripting is essentially user-coded routines that will run concurrently with the Adroit software. With these routines the user has the facility to manipulate agent data, manage User interface (UI) operations, control third-party data interfacing (via COM and OLE), automate complex tasks, perform mathematical operations and manage the look and feel of the Adroit application.Adroit scripting is developed in the following area: Script agent: greater control of agent server data through powerful mathematical and conditional scripting. Scripts execute at set time intervals or on change of data.Scripts are edited with an editor and debugger having colour syntax highlighting, script tips (VBA style syntax assistance) and a dialogue editor. A Microsoft™ script engine has been incorporated into Adroit thereby allowing integrators and end users to develop script in VB or Java. In addition to selecting which subroutine within the script is executed, separate initialisation and clean up subroutines can also be optionally configured.

Plant VCR

Plant VCR is essentially a more graphical alternative to historical trends. One may wish to traverse through the historical values of tags using existing pictures to diagnose and analyse plant conditions as they happened. Plant VCR can be thought of as a third mode for pictures, namely, editing, viewing (real time) and viewing (historical). The historical picture can be played backwards or forwards VCR style using the tag’s historical values at a configured speed, or one ‘freezed frame’ at a time in either direction. There is no configuration required to enable the operation of plant VCR for any existing or new picture in Adroit. However, all the tags in the picture that require historical playback need to be data logged.

1 - 62

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Visualisation and reporting softwareWorld class 32 bit

SCADA / HMI software

This key feature provides an open platform through which third-party applications communicate with Adroit.The OLE automation function together with the command set available in the automation interface allows for powerful data retrieval and manipulation that can easily be used for process monitoring, control, reporting, QA control and data archiving. In fact the scope of the automation interface is such that the complete configuration of an Adroit agent database is possible via an external package;– thereby bypassing the built-in agent configurator,

– allowing for rapid, rules-based tag generating.

Open systems connectivity

In days gone by, plant mimics were built using archaic bitmap techniques. Users came to accept the inherent restrictions imposed by these methods. There was no other choice.

A few years ago Adroit changed it all.

Since then users have been creating concise process graphics with the on-line vector-based drawing tools available in Adroit - mimics that automatically size to the display resolution to give crisp, clear images. Images that do not pixelate when sized, images made so life-like with 3D shading that it becomes difficult to distinguish the mimic from a photo.

That’s the power of Adroit.

Graphics

Efficient data logging and recall where disk space is optimised is old hat to Adroit (in Adroit the exception-based logging function only logs a value if it changes by more than a user-set amount – if a value does not change it is not logged. This leads to an efficient utilisation of disk space but not to “holes” in the log files, as Adroit has the built-in intelligence to recreate a complete set of time-based records at any time).Adroit has however taken its already highly efficient functions of data logging and data recall to yet another level of optimisation and flexibility, with increased data throughput and programme responsiveness when logging to huge databases. And now you can also log to named files, log on demand at any time, establish multiple logging rates per tag and have greater integrity with the log file systems.

With Adroit’s OLE DB connectivity you can now log directly

to any third-party database (SQL, MS ACCESS, ORACLE, ETC.)

Logging

1 - 63

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Visualisation and reporting softwareWorld class 32 bit

SCADA / HMI software

So you want to see how the temperature has changed over the last year, but still want to maintain realtime trending? With its built-in capability of trending up to eight variables per trend window, and letting the operator scroll from realtime to historical and back to realtime using the keyboard or mouse, Adroit offers a complete trending package. That’s the trend in Adroit – always way ahead of the rest.Adroit’s multi-colour trends dynamically change colour based on the alarm condition of the trend variable, while bookmarks allow you to insert notes into your trend.

Trending

Recipes provide an easy way to download process parameters to front-end devices, to automate routine tasks, and for constructing process simulations. In Adroit, recipes are made up of two components: a Master recipe and one or more associated control recipes. The Master recipe contains the ingredients to be used and the sequence that they will be downloaded, while the control recipe specifies the quantities the ingredients take on.Although essentially sequential in nature, Adroit recipes have the built-in capability to react to unexpected process deviations by executing process-related conditional branching instructions.A very high degree of process safety can therefore be achieved when using Adroit recipes.

Recipes

Alarms are events that need to be brought to the attention of the operator for action. Unfortunately most SCADA applications are over-alarmed where everything is alarmed in case it is needed.The result: a flood of meaningless alarms that the operator eventually starts ignoring.Can this happen with Adroit? No! Because Adroit provides a structure for configuring alarms that immediately allows for intelligent alarming practices. For example, groups of alarms can be disabled automatically by an internal or external event, alarms can be dynamically routed to various peripheral devices (mobile phones, pagers etc.) depending on process conditions, alarms can be globally acknowledged, and more.And above all, hierarchical alarm management scenarios are easy to setup and manage.That’s the power of Adroit.

Alarming

1 - 64

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Visualisation and reporting software World class 32 bit

SCADA / HMI software

Alarm Management

Alarm Management is an important aspect of process control required to counteract inefficient alarming.Alarm management allows you to create an alarming system that alerts the operator to the most relevant alarm for the current incident. In this case fewer alarms are more effective as the human mind can only focus on a few things at a time.The Alarm Management agent logs all incidents and their details, including their time of occurrence, their time of acknowledgement and the time at which they were cleared to a database. This repository of incidents then allows you to:

Generate statistics from the data produced by the alarming system. This allows you to have efficient and meaningful incident reviews to identify and remove nuisance alarms by analysing the counts, frequencies, durations and acknowledgement times of alarms.

Measure KPIs to improve your alarming configuration.

SMS Handling System

The Command agent can send and receive SMS messages by using a device of the GSM_SMS protocol driver. It uses the GSM_SMS driver, which sole function is the sending and receiving of SMS messages to and from GSM modems. The Command agent provides the following functionality:

Ability to both send and receive SMS messages of up to the full 160 character SMS message limit;

Send SMS messages to a single recipient, manually, programmatically or automatically to remotely monitor the status of important process values;

Monitoring of the sent SMS messages for auditing purposes. Sending a message to a different mobile number if no response is

received within a specified period; Receive SMS messages from one or more mobile phones, and if

necessary, perform commands to remotely supervise and control your process and configure Adroit (acknowledging alarms or fetching or setting process values etc.);

Ability to configure pseudonyms and macros to simplify the process of specifying commands by providing shorter aliases for the names of commonly referenced tags.

Built-in Auditing

Agent Server Auditing allows logging of the Agent Server’s sessions and selected activities performed during these sessions to an OLE DB database. In addition, by using the Audit Agent you can log the changes of values that are important to the running of your process, such as set point values and/or alarm limits.Generally, you will audit the Agent Server to provide a means of recourse in the event of a problem occurring to your process. Examining the audit logs you can determine any of the following user actions:

When the Agent Server was stopped and started; What agents have been added or removed from your Adroit installation; What Adroit documents have been saved; Which audited tags (as specified in the Audit agent) have changed in

value; Who the logged on user was, when these audited events occurred.

1 - 65

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Adroit is a modular system that is made up of 1 or more Servers and remote clients if required. The following steps will help guide you through the process of selecting the components required for an Adroit SCADA system

Step 1 – Select the Adroit SCADA Server

Select the Adroit SCADA Server Option you require. This is based on the number of external variables (Scan Points) you need to read or write to an external device. Internal variables 1) are not counted as part of the licence.

Step 2 (Optional) - Adroit SCADA Active Cluster (Redundant) Server if required

If your application requires the additional security of a backup server which will retain all of your data and enable you to continue to monitor and control your plant in the event of a failure of the server, then select an Adroit SCADA Active Cluster Server. The Active Cluster Server must match the Primary Server in terms of the number of Scan Points. Example: If you have selected a 750 Scan Point Primary Server, you must select the 750 Scan Point Active Cluster Server.

Step 3 (Optional) – Adroit SCADA Remote Clients if required

Both the Adroit SCADA Server and Adroit SCADA Active Cluster Server include a User Interface which means that they can both be used as an operation station. If, however, you require additional User Interfaces that are either located in a remote location from the Servers or would like to reduce the load on the servers by running them as dedicated servers, then select the Adroit SCADA Remote Client licence that matches your Server. Example: If you have selected a 150 Scan Point Adroit SCADA Server, then you must select 1 or more Adroit SCADA Remote Clients for 150 Scan Point Server.

UpgradesIf you already have an Adroit SCADA system and would like to upgrade to the latest version of Adroit or increase the size or your system, please contact NHP as the cost of the upgrade depends both on the version you are upgrading from and the system configuration, in terms of the number of scan points, the number of clients and whether your system has a redundant server pair (active cluster).

Adroit Technology AgreementAn alternative method of keeping your system up-to-date is via the Adroit Technology agreement. The agreement lasts for 12 months and entitles you to any new versions of Adroit that are released within the 12 months following the agreement start date. As for upgrades, please contact NHP if you wish to purchase a technology agreement. Please note that the Adroit Technology agreement provides a more cost effective method of keeping your Adroit SCADA software up-to-date with a built-in discount over standard upgrades.

Visualisation and reporting softwareAdroit SCADA

Ordering instructions

Note: 1) Internal Variables are variables which do not read or write data to or from an external device or software package.

Adroit Primary

Server

Adroit Active

Cluster Server

Adroit Primary

Server

Adroit ClientAdroit Client Adroit Client

Adroit Primary

Server

Adroit Active

Cluster Server

1 - 66

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

All prices are NETT

Visualisation and reporting softwareAdroit SCADA

SCADA Software

Ordering details

Notes: 1) 1 Scan Point = 1 PLC Variable. Internal variables are free. 2) Requires Adroit SCADA server Licence of equivalent number of Scan Points.

Adroit SCADA Server Options (Step 1)

Description Cat. No. Price $

30 Scan Point 1) Server and User Interface

75 Scan Point 1) Server and User Interface

150 Scan Point 1) Server and User Interface

300 Scan Point 1) Server and User Interface

750 Scan Point 1) Server and User Interface

1500 Scan Point 1) Server and User Interface

2500 Scan Point 1) Server and User Interface

5000 Scan Point 1) Server and User Interface

25000 Scan Point 1) Server and User Interface

Unlimited Scan Point 1) Server and User Interface

Adroit SCADA Active Cluster (Redundant) Server Options (Step 2 – optional)

30 Scan Point 1) Active Cluster 2) (Redundant) Server & User Interface

75 Scan Point 1) Active Cluster 2) (Redundant) Server & User Interface

150 Scan Point 1) Active Cluster 2) (Redundant) Server & User Interface

300 Scan Point 1) Active Cluster 2) (Redundant) Server & User Interface

750 Scan Point 1) Active Cluster 2) (Redundant) Server & User Interface

1500 Scan Point 1) Active Cluster 2) (Redundant) Server & User Interface

2500 Scan Point 1) Active Cluster 2) (Redundant) Server & User Interface

5000 Scan Point 1) Active Cluster 2) (Redundant) Server & User Interface

25000 Scan Point 1) Active Cluster 2) (Redundant) Server & User Interface

Unlimited Scan Point 1) Active Cluster 2) (Redundant) Server &

User Interface

Adroit SCADA Remote Client Options (Step 3 – optional)

Remote Client (User Interface) for 30 Scan Point 1) Server

Remote Client (User Interface) for 75 Scan Point 1) Server

Remote Client (User Interface) for 150 Scan Point 1) Server

Remote Client (User Interface) for 300 Scan Point 1) Server

Remote Client (User Interface) for 750 Scan Point 1) Server

Remote Client (User Interface) for 1500 Scan Point 1) Server

Remote Client (User Interface) for 2500 Scan Point 1) Server

Remote Client (User Interface) for 5000 Scan Point 1) Server

Remote Client (User Interface) for 25000 Scan Point 1) Server

Remote Client (User Interface) for Unlimited Scan Point 1) Server

ADROIT30SI

ADROIT75SI

ADROIT150SI

ADROIT300SI

ADROIT750SI

ADROIT1500SI

ADROIT2500SI

ADROIT5000SI

ADROIT25000SI

ADROITULSI

ADROIT30SI-A

ADROIT75SI-A

ADROIT150SI-A

ADROIT300SI-A

ADROIT750SI-A

ADROIT1500SI-A

ADROIT2500SI-A

ADROIT5000SI-A

ADROIT25000SI-A

ADROITULSI-A

ADROIT30RC

ADROIT75RC

ADROIT150RC

ADROIT300RC

ADROIT750RC

ADROIT1500RC

ADROIT2500RC

ADROIT5000RC

ADROIT25000RC

ADROITULRC

Adroit ServerAdroit Server

Adroit Active Cluster

(Redundant) Server

Adroit Server

Adroit Stand-alone

Server

Adroit Server

Adroit Remote Clients

Adroit ClientAdroit Client

1 - 67

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

All prices are NETT

Visualisation and reporting softwareAdroit SCADA

SCADA Software

Ordering details

Adroit Upgrades and Maintenance Agreements

Description

Adroit Upgrade

The cost to upgrade from a previous version of Adroit depends both on the version number you are upgrading from and the system configuration in terms of the number of scan points, the number of clients and whether your system has a redundant server pair (cluster).Please contact NHP for a quote on Adroit Upgrades.

Adroit Technology Agreement

The Technology Agreement is a 12 month contract which entitles you to all Adroit upgrades and premium support for the period of the contract. The cost of the Technology Agreement depends both on the version number you have and the system configuration in terms of the number of scan points, the number of clients and whether your system has a redundant server pair (cluster).Please contact NHP for pricing on Adroit Technology Agreements.

Notes: 1 Scan Point = 1 PLC Variable. Internal variables are free. Other variants including redundant servers (Clusters) available. Please contact NHP for more information.

Price $

Price $

Training

Adroit configuration Level I - 2 day course. This course is targeted at new Adroit users, configurators, technicians and engineers. The course sets the foundation for the next level course and provides delegates with the tools to implement and configure small projects. All commonly used features are covered in appropriate detail. The pre-requisite for attending this course is an understanding of SCADA and an operational knowledge of Microsoft Windows 95/98. Operational experience of Microsoft Windows 2000 / XP is an advantage.

Adroit configuration Level II - 2 day course. This course is targeted at Adroit users, configurators, technicians and engineers who have successfully implemented at least one project. The concepts and principals presented in the Level I course are covered in depth, while additional features are introduced and explained. The pre-requisite for attending this course is the Level I configuration course as well as project experience.

Contact NHP for further information.

1 - 68

1

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘E9’

Switch mode power supplies

Features

5 year warrantyQuick mounting and connecting, innovative DIN railHigh efficiency

Low power lossElectronic protection from short circuit, overload and over-voltageVoltage limitingAdjustable output

Notes: 1) Wide range single-phase input 2) Double range single-phase input 3) Two-phase input 4) Three-phase input 5) With Oring diode for redundant parallel

6) With failure contact (power good) 7) With adjustable output 8) UL508C approved

XCSD15B 1)8)

XCSD30C 1)8)

XCSD50B 1)7)8)

XCSD70C 1)8)

XCSL85C 1)8)

XCSF85CP 1)5)6)8)

XCSF120B1)6)7)8)

XCSL120C 1)8)

XCSF120CP1)5)6)8)

XCSF120D 1)6)8)

XCSF240B 2)6)7)8)

XCSL240C 2)8)

XCSF240CP2)5)6)8)

XCSF240D 2)6)8)

XCSF500C 2)6)8)

Single phase switching power supplies

15

30

50

85

120

240

500

Cat No. Price $

Output power (W)

Output voltage

12 V DC

24 V DC

12...15 V DC

24 V DC

24 V DC

12...15 V DC

24 V DC

48 V DC

12...15 V DC

24 V DC

48 V DC

24 V DC

Output current (A)

Inrush current Model type

CSD Series

CSD Series

CSD Series

CSD Series

CSL Series

CSF Series

CSF Series

CSL Series

CSF Series

CSF Series

CSF Series

CSL Series

CSF Series

CSF Series

CSF Series

1.2

1.2

3.5

3

3.5

7

5

2.5

16

10

5

20

<5 A

<13 A

<15 A

<15 A

<20 A

<20 A

<35 A

<25 A

XCSBC

XCSBD

AccessoriesCat No. Price $Description

PS Batt charger module

PS redundant conn module

CSD series

CSF Series

CSL series

CSG Series

XCSB150C 3)8)

XCSB150D 3)8)

XCSG240C 4)6)8)

XCSG500C 4)6)8)

XCSG720C 4)6)8)

XCSG42 4)8)

XCSG2400C 4)8)

Three phase switching power supplies

150

240

500

720

1008

2400

Cat No. Price $

Output power (W)

Output voltage

24 V DC

48 V DC

24 V DC

24 V DC

24 V DC

24 V DC

24 V DC

Output current (A)

Inrush current Model type

CSG Series

CSG Series

CSG Series

CSG Series

CSG Series

CSG Series

CSG Series

<50 A

<50 A

<35 A

<30 A

<20 A

<130 A

6

3

10

20

30

40

100

XCSA120BC

XCSA120CB

XCSA120DC

Cat No. Price $

Input voltage V (DC)

12

24

48

Output voltage V (DC)

24

12...15

24

Output current (A)

5

7

5

Inrush current

<60 A / <2ms

<100 A / <2ms

<120 A / <2ms120

Output power (W)

DC/DC Insulated converters

2 - 1

Safety2

Safety interlock switches

Series ST - 14: Light duty 2 - 2Series ES - 95: General purpose 2 - 2Series ST - 61: Heavy Duty 2 - 3Series ES - 95: General purpose rotary cam 2 - 4Series ES - 13SB: Light duty hinged 2 - 4Series ES - 95: General purpose flap/hinge 2 - 4Series STM 295: Medium duty solenoid 2 - 5Series AZM 415: Heavy duty Solenoid 2 - 5Non-contact Safety switches

Series RC Si - M30 2 - 6Series RC Si - 56 2 - 6Series HSSi4 2 - 7Series BZ16 2 - 7Emergency stop trip-wire switch kits 2 - 8Emergency stop trip-wire switches 2 - 9Belt drift switches 2 - 10Limit switches

Light duty 6 A: ES/EM 95 series 2 - 11Medium duty 10 A: PS21 series 2 - 11Medium duty 10 A: PS31 series 2 - 12Medium Duty 6 A:ES/EM 41 series 2 - 12Emergency stop trip-wire switches

Type NTW cast aluminium 2 - 13 to 2 - 18Spare parts and accessories 2 - 15 to 2 - 16Installation instructions 2 - 17 to 2 - 18Heavy-duty limit switches: 77 HL and 77 TL series 2 - 19Safety Controllers

Series NSC: Fail safe control unit 2 - 20Series MF1: Standstill monitor 2 - 20Series SRM: Fail safe control unit 2 - 20Limit switches - pull-wire (non safety) 2 - 21Foot operated switches 2 - 22Pressure switches 2 - 23

SAFETY INTEREEEEEEEERRRRRRRRRRRRRRRRRLLLLLOOOOOOCCCCCCCKKKKKK WITCHESSSSSSSSSSSSWWWWWWWWWWWWWWWWWWWW

FOOT OPERATED SWITCHES

NON-CONTACT SAFETY SSS SWITCHESS

LIMMIT LLLLLLLLLIIIIIIIIIMMMMMMMMMIIIIIIIIIITTTTTTTTTTTT SWITCCHHEESS

PRESSURRE SWITCHESEEMERGENCY STTOPP TTRRIIPP-WIRE SWITCHESS

EEMMEERRGGEENNCCYY STTOOPP TTRRIIPP-WWIIRREE SSWWITCHH KKITTSS

2 - 2

2

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule 'B2'

Safety interlock switches

Series ST -14: Safety interlock switchLight Duty - safety guard interlock IP 67

Series ES-95: Safety interlock switchGeneral purpose - safety interlock switch - machine guards IP 67

ST14 B1

ST14 B5

ST14 B3

Accessories - actuators

Actuator Straight for ST14

Actuator Right angle for ST14

Actuator Spring loaded for ST14

Price $

Switch Cat. No.

95AZB1

95AZB5

Accessories - actuators

Actuator Straight for ES95

Actuator Right angle for ES95

Price $

Switch Cat. No.

ST14

11

15

53

16 7,58

ø4

.2

Rmin.140

Rmin.1000

11

8

3538

16 1530

ø4.2

Rmin.140

Rmin.1000

ST 14 B1 ST 14 B5 ST 14 B3

ES95AZ

95AZB1 95AZB5

Dimensions in mm

Dimensions in mm

1 N/O + 1 N/C

2 N/C

1 N/O + 1 N/C Ex-version

Contacts

ST14-10/1S

ST14-20

EEXST-14-10/1S 5M

Price $

Switch Cat. No.Actuator Action Type

Retaining

Retaining

Retaining

BAC19

BAC19

BAC19

Fencing Adaptor

1 N/O + 1 N/C

2 N/C

Contacts

ES95AZ101S

ES95AZ20

Price $Switch Cat. No.Actuator Action Type

Retaining

RetainingBAC20

BAC20

Fencing Adaptor

2 - 3

22

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Safety interlock switches

Price Schedule 'B2'

Series ST-61: Safety interlock switchHeavy Duty - safety interlock switch - machine guards IP 65

ST61 B1

ST61 B5

Accessories - actuators

Actuator Straight for ST61

Actuator Right angle for ST61

Price $Switch Cat. No.

ST6110 1S

Dimensions in mm

ST61 B1

ST61 B5

1 N/O + 1 N/C

2 N/C

Contacts

ST6110/1S

ST6120

Price $Switch Cat. No.Actuator Action Type

Retaining

Retaining

BAC21

BAC21

Fencing Adaptor

2 - 4

2

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Safety interlock switches

Price Schedule 'B2'

Series ES-13: Rotary cam interlock switchLight duty safety switch - guards, doors, covers, etc.

1 N/O + 1 N/C

Contacts

ES13SB101S

Price $

Switch Cat. No.IP Rating

IP 67 Thermoplastic

Material

Series ES-95: Rotary cam interlock switchGeneral purpose safety switch - guards, doors, covers, etc.

1 N/O + 1 N/C

2 N/C

Contacts

ES95SB101S

ES95SB20

Price $

Switch Cat. No.IP Rating

IP 67

IP 67

Thermoplastic

Thermoplastic

Material

ES95T5C101S

ES13SB101S

ES95SB101S

Series ES-95: Flap/hinge safety switchGeneral purpose safety switch - machine guards

1 N/O + 1 N/C

Contacts

ES95T5C101S

Price $

Switch Cat. No.IP Rating

IP 67 Thermoplastic

Material

2 - 5

22

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule 'B2'

Safety interlock switches

Series AZM 415: Heavy duty solenoid safety interlock switch Removable guards, doors, covers, etc. IP 67

AZM415 B1

AZM415 B2

AZM415 B3

Accessories - actuators

Actuator Straight for AZM415

Actuator Adjustable X axis for AZM 415

Actuator Adjustable Y axis for AZM 415

Price $

Switch Cat. No.

Series STM: 295 Medium duty solenoid safety interlock switchRemovable guards, doors, covers, etc. IP 67

STM295 B1

STM295 B5

Accessories - actuators

Actuator Straight for STM295

Actuator Right angle for STM295

Price $

Switch Cat. No.

STM295202SR

AZM415202SR3D

STM295 B1 STM295 B5

Dimensions in mm

Dimensions in mm

AZM415 B1 AZM415 B2 AZM415 B3

2 N/O + 2 N/C

2 N/0 + 2 N/C

Contacts

STM295202SR

STM295202SA

Price $

Switch Cat. No.Solenoid Action

Power unlock

Power lock

24 V DC

24 V DC

Solenoid Voltage

BAC22

BAC22

Fencing Adaptor

2 N/O + 2 N/C

2 N/0 + 2 N/C

Contacts

AZM415202SR3D

AZM415202SA3D

Price $

Switch Cat. No.Solenoid Action

Power unlock

Power lock

24 V DC

24 V DC

Solenoid Voltage

BAC23

BAC23

Fencing Adaptor

2 - 6

2

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule 'B2'

Non-contact safety switches

Series RC Si-56: Magnetic coded safety switches - IP 67RC Si Recommended to be used with SRM 21 RT2 relay

Series RC Si-M30: Magnetic coded safety switches - IP 67RC Si Recommended to be used with SRM 21 RT2 relay

1 N/O + 1 N/C

2 N/C

Contacts

RCSIM30101S5M

RCSIM30205M

Price $Cat. No.Description

Magnetic cylinder M30

Magnetic cylinder M30

MC56

Accessories - actuators

Coded magnet

Price $Cat. No.

MC30

Accessories - actuators

Coded magnet

Price $Cat. No.

RCSI56101S5M

RCSIM30101S5M

Dimensions in mm

MC56-3

Dimensions in mm

MC30

1 N/O + 1 N/C

2 N/C

Contacts

RCSI56101S5M

RCSI56205M

Price $Cat. No.Description

Magnetic switch rectangle

Magnetic switch rectangle

BAC24

BAC24

Fencing Adaptor

2 - 7

22

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Non-contact safety switches

Series HSSi 4 : Hall sensor - IP 67General duty guard door monitor

Price $Cat. No.

HSSI4101S

HSSI420

Descriptions Contacts

Hall sensor

Hall sensor

1 N/O + 1 N/C

2 N/C

Price $Cat. No.

MC4

Accessories - actuators

Actuator

RCSIM30101S5M

HSSI4101S

BZ16 11

BZ16 B1

Series BZ16 : Induction/Hall sensor - IP 67General duty guard door monitor

Price $Cat. No.

BZ1611V

BZ1611D

BZ1611U

BZ1602V

BZ1602D

BZ1602U

Face actuation Contacts

Front

Top

Bottom

Front

Top

Bottom

1 N/O + 1 N/C

1 N/O + 1 N/C

1 N/O + 1 N/C

2 N/C

2 N/C

2 N/C

Price $Cat. No.

BZ16B1

Accessories - actuators

Actuator

Actuation face

Price Schedule 'B2'

2 - 8

2

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘B2’

Emergency stop trip-wire switch “kits”

Notes: 1) Items included in all of the above kits

1 x Tension spring (As per requirement AS 1755-2000) 1 x 55164, turnbuckle 4 x 55151, thimble 8 x 55152, wire clamps _ x Cable (quantity as above) _ x 55150, wire support (quantity as above) Wire supports are based upon supporting the trip-wire at 2.5 - 3 metre intervals.

TQZS-75...

TQZS-73...

TQZS-71...

TQZS-80

TQZS-70

Series TQ ZS: Trip-wire switchesEmergency stop for conveyor and various other industries

TQZS70...8 metresSlim housing

Price $Cat. No

TQZS70KIT10M

Trip-wireSwitch

TQZS70... kit

TQZS70101SVD

Items included in kit 1)Trip-wire length

8 metres

1 x TQZSTS150N

8 x TQZSWR5MM (cable)

3 x 55150 (wire support)

TQZS71...5-20 metresSmall housing

TQZS71KIT20M

TQZS71... kit

TQZS71101 20 metres

1 x TQZSTS250N

20 x 55153P (cable)

5 x 55150 (wire support)

TQZS73...30-50 metresGeneral purpose

TQZS73KIT50M

TQZS73... kit

TQZS3101SWVD 50 metres

1 x TQZSTS250N (spring)

50 x 55153P (cable)

10 x 55150 (wire support)

TQZS-75...30-50 metresLarge housing

TQZS75KIT50M

TQZS75... kit

TQZS75101SWVD 50 metres

1 x TQZSTS250N (spring)

50 x 55153P (cable)

10 x 55150 (wire support)

TQZS80...10-50 metresWith emergency stop and flag indicator

TQZS80KIT50M

TQZS80... kit

TQZS80202SWVD 50 metres

1 x TQZSTS250N (spring)

50 x 55153P (cable)

10 x 55150 (wire support)

2 - 9

22

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Emergency stop trip-wire switches

Price Schedule ‘B2’

Price $Cat. No.

TQ441 01/01 YUR 137 1)

TQ441 01/01 YUR 157 2)

TQ441 01/01 YUR 1)

Trip-wirelength (metres) Contact arrangement Description

5-25 m

0-5 m

5-25 m

(1 N/C + 1 N/C)

(1 N/C + 1 N/C)

(1 N/C + 1 N/C)

Cast Iron Body

35 N Type

Cast Aluminium

Series TQ441/T3Z : Trip-wire switchEmergency stop for conveyor and various other industries

Series TQZS : Trip-wire switchesEmergency stop for conveyor and various other industries

Price $Cat. No.

55153P

TQZSTS250N

TQZSTS150N

55150

55152

55151

55164

S900

Description

Steel wire red PVC covered 7 mm Ø (per metre)

Tension spring heavy duty

Tension spring light duty

Wire support bracket

Wire clamp / shackle

Thimble

Turnbuckle

Tensioning device (for 5 mm Ø wire)

Trip-wire switch accessories

55153P

Wire rope

Trip-wire switch

TQ441-01/01YUR137

55152

Wire clamp

55150

Wire support

Notes: 1) Use in combination with TQZSTS250N tension spring and 55153P 7 mm wire rope. 2) Use in combination with TQZSTS150N tension spring and TQZSWR5MM 5 mm wire rope.

Price $Cat. No.

TQZS-70 10/1S VD 2)

TQZS-71 10/1SWVD 1)

TQZS-71 20 WVD 1)

EEXZS-71 10/1S WVD 1)

TQZS-73 10/1SWVD 1)

TQZ-73 20 WVD 1)

EEXZS-73 10/1S WVD 1)

TQZS-75 10/1S WVD 1)

TQZS-75 20/2S WVD 1)

TQZS-80 20/2S WVD 1)

Trip-wirelength (metres) Contact arrangement Description

0-8 m

5-20 m

5-20 m

5-20 m

30-50 m

30-50 m

30-50 m

30-50 m

30-50 m

10-50 m

(1 N/O + 1 N/C)

(1 N/O + 1 N/C)

(2 N/C)

(1 N/O + 1 N/C)

(1 N/O + 1 N/C)

(2 N/C)

(1 N/O + 1 N/C)

(1 N/O + 1 N/C)

(2 N/O + 2 N/C)

(2 N/O + 2 N/C)

Ex version

Ex version

2 - 10

2

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Belt drift switches

Series ES 61 SR: Belt drift switchLight duty

Series ZS 73 SR: Belt drift switchGeneral duty

Series ZS 75 SR: Belt drift switchGeneral duty

Price Schedule ‘B2’

ES61SR101S

ZS73SR101S

ZS90SR202S

Price $Cat. No.IP Rating

ES61SR101SIP 65 Aluminium

Material

1 N/O + 1 N/C

Contacts

Price $Cat. No.Description

ZS73SR101SIP 65 Aluminium

Material

1 N/O + 1 N/C

Contacts

Price $Cat. No.IP Rating

ZS75SR101S

ZS75SR202S

IP 65

IP 65Aluminium

Aluminium

Material

1 N/O + 1 N/C

2 N/O + 2 N/C

Contacts

Series ZS 90 SR: Belt drift switchHeavy duty

Price $Cat. No.IP Rating

ZS90SR10S10SIP 67 Duroplast

Material

2 N/O + 2 N/C

ContactsZS75SR101S

2 - 11

22

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Limit switches

Price Schedule 'B2'

Light Duty 6A (Ithe) IP 67 ES/EM 95 series 1)1 N/O & 1 N/C

Medium Duty 10A (Ithe) IP 66 PS 21 L series 1)1 N/O & 1 N/C

Notes: 1) Versions with 2 N/0 or 2 N/C contacts available on indent.

ES95W101S

ES95D101S

ES95DS101S

PS21LMS11PR00

PS21LMS11POM00

Dimensions in mm

Dimensions in mmØ10/0.39”

37/1

.46”

107/

4.21

16/0.63”

PS21L

ES95

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Price $Cat. No.

ES95W1O1S

EM95W1O1S

ES95R1O1S

EM95R1O1S

ES954K1O1S

EM954K1O1S

ES95D1O1S

EM95D1O1S

ES95DS1O1S

EM95DS1O1S

ES95DD1O1S

EM95DD1O1S

ES95TL1O1S

EM95TL1O1S

ES95TK1O1S

EM95TK1O1S

Actuator Action

Slow

Snap

Slow

Snap

Slow

Snap

Slow

Snap

Slow

Snap

Slow

Snap

Slow

Snap

Slow

Snap

Body Material

W

4K

R

D

DS

DD

TL

TK

Metal

Metal

Metal

Metal

Metal

Metal

Metal

Metal

Price $Cat. No.

PS21LM11P0M00

PS21LMS11P0M00

PS21LMT11PRM00

PS21LMS11PRM00

PS21LMT11RTM00

PS21LMS11RTM00

PS21LMT11R1M00

PS21LMS11R1M00

Actuator Action

Slow

Snap

Slow

Snap

Slow

Snap

Slow

Snap

Body Material

PO

PR

RT

R1

2 - 12

2

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘B2’

Limit switches

Medium duty 10A (Ithe) IP 65 PS 31 L series 1)1 N/O & 1 N/C

Heavy duty 6A (Ithe) IP 65 ES/EM 41 series 2)1 N/O & 1 N/C

Notes: 1) Versions with 2 N/O or 2 N/C contacts available on indent, except Steute snap action models. 2) Versions with 2 N/C contacts available on indent.

Ø12/0.47”

20/0

.79”

44/1

.73”

30°

50/1

.97”

120/

4.72

16/0.63”10/0.39”

5/0.20”

Ø10/0.39”

37/1

.46”

107/

4.21

16/0.63”

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Plastic

Price $Cat. No.

PS31LMT11P0T00

PS31LMS11P0T00

PS31LMT11PRT00

PS31LMS11PRT00

PS31LMT11RVT00

PS31LMS11RVT00

PS31LMT11RTT00

PS31LMS11RTT00

PS31LMT11R1T00

PS31LMS11R1T00

Actuator Action

Slow

Snap

Slow

Snap

Slow

Snap

Slow

Snap

Slow

Snap

Body Material

PO

RV

PR

RT

R1

Metal

Metal

Metal

Metal

Metal

Metal

Metal

Metal

Metal

Price $Cat. No.

ES41

EM411O1S

ES41R1O1S

EM41R1O1S

ES41D1O1S

EM41D1O1S

ES41DS1O1S

EM41DS1O1S

EM41TL1O1S

Actuator Action

Slow

Snap

Slow

Snap

Slow

Snap

Slow

Snap

Snap

Body Material

W

D

R

DS

TL

PS31LMT11RT00

ES41R101S

ES41DS101S

ES41TL101S

PS31LMS11RT00Dimensions in mm

Dimensions in mm

ES41

2 - 13

22

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Emergency stop trip-wire switch Type NTW Cast aluminium type

Protection class IP 65 and IP 67

Features

Rugged construction - cast aluminium housing Non-ferrous components throughout All operating shafts & springs are stainless steel Hoseproof - dustproof IP 65 & IP 67 enclosure Complies with AS 1755-2000/AS 1939-1990 Standard unit supplied with 2 N/O + 2 N/C silver wiping action contacts. Flag indicator & padlocking facility supplied as standard

(Padlocking is for prevention of manual reset only) Single or double sided operation Fail-safe mechanism including removal or breakage of either wire Cannot break the N/C circuit without latching open Switch must be manually reset Ex Version complies with AS/NZS 61241

Trip-wire switch with

flag indicator, pilot

light, lamp and lens

55.4.01 NBB

Padlocking feature

Optional window for

external adjustment

IP 65/67 protection

UV resistant

neoprene seals

Manual reset

Pilot light/indicator

Refer Publication

55-NTW, C-100

2 - 14

2

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

1380.00

1580.00

1390.00

1800.00

Price Schedule ‘B2’

Emergency stop trip-wire switch Type NTW

Standard switch with 2 N/O

+ 2 N/C contact blocks

Standard switch with glass

window and 2 N/O + 2 N/C

contact block

Standard switch with pilot

light and 2 N/O + 2 N/C

contact block 4)

Standard switch with amber

strobe indication and 2 N/O

+ 2 N/C contact block 6)

Description Price $

Trip-wire switchsingle-sided leftCat. No. 1) 2) 3) Price $

55.4.00NBB

55.4.00GWNBB

55.4.01NBB

55.4.01STRANBB

55.4.00RHNBB

55.4.00RHGWNBB

55.4.01RHNBB

55.4.00LHNBB

55.4.00LHGWNBB

55.4.01LHNBB

1400.00

1610.00

1480.00

Notes: 1) Installation information, lanyard rope and accessories, refer pages 6 - 15 to 6 - 18.

2) Also available with gold plated contacts at extra cost – insert ‘G’ at the end of Cat. No. Contact NHP for additional price.

3) Suitable for use with conveyor control and monitoring communications systems. Contact the NHP Automation team to discuss your requirements.

4) Supplied with red and amber lenses, lamp must be ordered separately. 5) Supplied with red lens, lamp must be ordered separately. 6) Supplied with Allen-Bradley 45 mm strobe light 855PSB30ME522.

Trip wire switch with

glass window

55.4.00 GWNBB

NTW Trip-wire switches, standard range

IP 65/IP 67 padlockable trip-wire switches Single-sided or double-sided operation Supplied with silver wiping action contact blocks

(gold available on request).

Ordering details

55.4.00LH NBB

55.4.01 NBB

Price $

Trip-wire switchdouble-sidedCat. No. 1) 2) 3)

Standard switch with 2 N/O

+ 2 N/C contact block

Description Price $

Switch withGlass window

Cat. No. 1) 2) Price $

Switch with lid mounted pilot light

Cat. No. 1) 2) 5)

EX55400NBB 1710.00 EX55401NBBEX55400GWNBB 1970.00

Price $Standard switch Cat. No. 1) 2)

Explosion proof (Ex) trip-wire switch

Special trip-wire switch for hazardous environments such as grain handling. Supplied with 2 N/O + 2 N/C contact blocks. Complies with AS/NZS 61241.

Ex 55.4.00 NBB

Trip-wire switchsingle-sided rightCat. No. 1) 2) 3)

Dimensions (in mm)

2 - 15

22

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price $

StandardSilver contactCat. No.

Price Schedule ‘B2’

Price $StandardCat. No.

Emergency stop trip-wire switch Type NTW

Spare contact blocks/Lamp block

NBAFP

NBBFP

-

VFBC

55.00

109.00

106.00

NBAG

NBBG

554LVKIT

-

1 N/O + 1 N/C contacts

2 N/O + 2 N/C contacts

3 N/O + 3 N/C low voltage micro contact set

and bracket

Lamp block for 55.4.01 (suit SES lamp)

Spare lamps SES style for trip-wire pilot light 5) 6)

NO2243

NO2242

NO2551

NO2556

Full voltage pilot light

Full voltage pilot light

Resistor and full voltage pilot light

Resistor and full voltage pilot light

12 V 4 W

24 V 4 W

110 V 4 W

260 V 4 W

55.1.50

wire support

55.1.52

wire clamp

2551

SES 110V lamp

55.2.46

Tension spring

55.1.51

Thimble / sleeve

Notes: 1) 55.2.46 tension spring is only suitable for NTW 55.4 trip-wire switches. 2) Supplied complete with gasket 55.2.17. 3) Use with clip 55.2.40. 4) Eye/Eye turnbuckle available contact NHP. 5) Other voltages available contact NHP. 6) Stock brought in to order on some voltages.

To suit

-

55.2.46

55.1.50

55.1.51

55.1.52

55.1.64

80.00

29.60

11.40

9.90

33.00

55.2.19NTW

55.2.46SS

55.1.50SS

55.1.51SS

55.1.52SS

55.1.64SS

Price $

316 Grade Stainless SteelCat. No.Description

‘D’ Shackle

Tension spring suits NTW 55.4 only 1)

Lanyard support bracket

5 mm thimble/sleeve

5 mm clamp/shackle

Turnbuckle hook and eye 10 mm x 145 mm 4)

Lanyard accessories

Price $

Gold contactCat. No.

Price $Cat. No.

55.2.17

55.2.37

55.2.16

55.2.16GW

55.2.16PL

Price $Cat. No.

Lid gasket

Shaft bellows 3)

Spare Lid for 55.4.00 2)

Spare Lid for 55.4.00GW 2)

Spare Lid for 55.4.01 2)

Spare parts

Voltage SES

2 - 16

2

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘A2’

Refer catalogue SAFT

NHP/Tufflex™ fibre lanyard rope

A unique combination of properties differentiates NHP/Tufflex™ fibre from other high-performance fibres and makes it the material of choice to meet performance requirements in demanding applications. The remarkable mechanical performance of NHP/Tufflex™ combined with the other unique properties, permit it to be used for a wide variety of purposes. NHP/Tufflex™ unique fibres are used in aerospace, ocean exploration and development, electronic support structures, safety materials, industrial applications, composites, protective apparel and high-pressure inflatables.NHP/Tufflex™ is a high-performance multi-filament yarn spun from liquid crystal polymer (LCP). It is the only commercially available melt-spun LCP fibre in the world exhibiting low weight and exceptional strength and rigidity. It is five times stronger than steel and ten times stronger than aluminium.

These unique properties characterise NHP/Tufflex™:

High strength and modulus Low coefficient of thermal expansion (CTE) Excellent creep resistance High dielectric strength High abrasion resistance Outstanding cut resistance Excellent flex/fold characteristics Excellent property retention at high/low temperatures Minimal moisture absorption Outstanding vibration damping characteristics Excellent chemical resistance High impact resistance

Per metre Price $Cat. No.

55.1.53P

Description

Wire rope 7 mm dia.

(4 mm wire coated in 3 mm RED UV resistant PVC)

Lanyard rope / Trip-wire

Developed to meet AS/NZS conveyor safety standard AS 1755-2000 these ropes are specially tested to work in conjunction with the NHP/Austrol NTW 55.4 series trip wire switches. Two types are available, i.e. PVC covered galvanised trip-wire, and the new NHP/Tufflex™ fibre lanyard rope.

Emergency stop trip-wire switch Type NTW

Accessories and spare parts

Price $Cat. No.

55.1.53RLR

55.1.53RLR-PM

Description

NHP/Tufflex™ RED fibre lanyard rope 7mm dia. (105 m roll)

NHP/Tufflex™ RED fibre lanyard rope 7mm dia. per metre

Ordering detailsRed PVC covered galvanised trip-wire

Ordering details

LCP Fibre lanyard rope

55.1.53P

See page 6 - 17 to 6 - 18 for set up instructions.

See page 6 - 15 for spare parts and accessories.

55.1.53RLR

2 - 17

22

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

• Individual maximum lengths of lanyard (shown as ‘X’ in the diagrams above) in a horizontal plane must not exceed:

– 100 m when using NHP/Tufflex™ Lanyard rope (Cat. No. 55.1.53RLR) – 60 m when using NHP red PVC coated galvanised steel cable (Cat. No. 55.1.53P)• NHP recommends the use of NHP/Tufflex™ as the lanyard when the conveyor system is operating over

a 5 degree incline from the horizontal. • NHP strongly recommends that pulleys are not used with the galvanised steel cable – i.e to curve the

tripwire/lanyard around conveyor bends, etc. – and that pulleys only be used with NHP/Tufflex™ as the lanyard.

Emergency stop trip-wire switch Type NTW – Protection class IP 65 and IP 67

Method of installationFor single and double-sided operation

Single-sided operationTripwire/lanyard connected to one side of the trip-wire switch (either left or right) and terminated with a return compensation (tension) spring.

Multiple double-sided installationsFor longer conveyor runs, must be installed as shown below:

Double-sided operationTripwire/lanyard connected to both left and right hand sides of the trip-wire switch. Both left and right hand lanyards are terminated with a return compensation (tension) spring.

X Metres Max.

TurnbuckleTension Spring

55.2.46 55.1.64

55.1.50

Wire Supports

4.0 4.0

X Metres Max.

Turnbuckle Tension Spring

X Metres Max.

TurnbuckleTension Spring

55.2.46 55.1.64

55.1.50

55.1.64 55.2.46

55.1.50

Wire Supports

4.0 4.0

Wire Supports

4.0 4.0

X Metres Max.

Turnbuckle Tension Spring

X Metres Max.

TurnbuckleTension Spring

55.2.46 55.1.64

55.1.50

55.1.64 55.2.46

55.1.50

Wire Supports

4.0 4.0

Wire Supports

4.0 4.0

X Metres Max.

Turnbuckle Tension Spring

X Metres Max.

TurnbuckleTension Spring

55.2.46 55.1.64

55.1.50

55.1.64 55.2.46

55.1.50

Wire Supports

4.0 4.0

Wire Supports

4.0 4.0

2 - 18

2

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

1. Firmly mount the trip-wire switch using the four (4) mounting points on the trip-wire unit: A. For Double-Sided Installations

• A maximum of 100 m from one end of the conveyor when using NHP/Tufflex™, or • A maximum of 60 m from one end of the conveyor when using NHP PVC coated

galvanised cable as the lanyard.

B. For Single-Sided Installation

Mount the trip-wire switch at one end of the conveyor, ensuring that the maximum length of the tripwire/lanyard does not exceed: • 100 m when using NHP/Tufflex™ or, • 60 m when using NHP PVC coated galvanised wire as the lanyard.

Note: If either of the above distances are to be exceeded, then a double-sided installation must be used.

2. Fit the return compensation (tension) spring: C. When using NHP/Tufflex™ as the lanyard:

A maximum of 100 m from each side of the trip-wire switch for double-sided installations, or a maximum of 100 m from one side of the trip-wire switch for single-sided installations.

D. When using NHP PVC coated galvanised steel wire as the lanyard:

A maximum of 60 m from each side of the trip-wire switch for double-sided installations, or a maximum of 60 m from one side of the trip-wire switch for single-sided installations.

3. Position lanyard wire supports at a maximum spacing of 4 m between the return compensation spring and the trip-wire switches. Smaller spacings will ensure higher performance of the trip-wire system.

4. Run the lanyard between the trip-wire switch and the return compensation springs.

5. Terminate the lanyard at the return compensation spring ends using thimbles and clamps. If using the PVC coated galvanised cable, remove outer PVC sheathing before clamping. Secure to the return compensation spring using ‘D’ shackle if necessary.

6. Unwind both ends of the turnbuckle/s to give maximum extension and hook one end to the shaft of the trip-wire switch using the provided ‘D’ shackle.

7. Terminate the other end of the lanyard to the turnbuckle/s using thimbles and clamps. If using the PVC coated galvanised cable, remove outer PVC sheathing before clamping. Before tightening clamp to lanyard, pull through all slack until taught, then tighten clamp.

8. Attach the external setting gauge/s using the screws provided, into the threaded holes, either above or below the external trip-wire switch shafts.

9. Adjust the turnbuckle/s until the end of the shaft is in-line with the end of the setting gauge.

10. Pull the lanyard numerous times to ‘bed-in’ the cable and remove any ‘deadband’ from the system. If necessary, re-adjust the turnbuckle until the end of the shaft is in-line with the end of the setting gauge. If desired, the setting gauge can now be removed.

11. The trip-wire switch set-up is now complete.

55.4.00 NBB Open view Schematic showing operating

lever centred in the middle of

the operating cam.

Emergency stop trip-wire switch Type NTW – Protection class IP 65 and IP 67

Method of installationFor single and double-sided operation

2 - 19

22

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Heavy-duty limit switches77 HL and 77 TL Series

Hatchway limit switch

double pole 77.1.10

with 77.2.40 lever

Track limit switch

double pole 77.2.11

with 77.2.39 lever

Lever- rod or chain

77.2.34

Double pole contact

block 77.1.31

Features of 77 series switches

Australian designed and manufactured Proven reliability in adverse conditions Durable cast construction Weatherproof and dustproof to IP 54 Double-break long life silver contacts 1) 10 Amp 440 V AC 12 Non-ferrous metal components Optional roller styles

(track limit switches only) Selectable side or bottom mounting

(hatchway only)

77.1.06

77.1.10

Price $Cat. No.Description

Hatchway limit switch with straight roller lever and

single pole contact

Hatchway limit switch with straight roller lever and

changeover contacts

Series 77 HL Cast aluminum Hatchway limit switch 1) (Spring return to centre)

1 N/O or 1 N/C

1 N/O + 1 N/C

Contacts 1)

77.2.50

77.2.11

Price $Cat. No.Description

Track limit switch without lever and single pole

contact - choose lever below

Track limit switch without lever, with changeover

contacts - choose lever below

Series 77 TL Cast iron Track limit switch 1) (Stayput)

1 N/O or 1 N/C

1 N/O + 1 N/C

Contacts 1)

77.1.30

77.1.31

77.2.34

77.1.21

77.1.25

77.2.40

77.2.39

Price $Cat. No.Description

Single pole contact blocks (spare part)

Changeover contact blocks (spare part)

Spare rod or chain lever - for 77 TL switches only

Spare cam for changeover contacts

Spare cam screw for changeover contacts

Spare lever straight - for HL switches

Spare lever fork - for TL switches

Accessories for series 77 HL and 77 TL switches

1 N/O or 1 N/C

1 N/O + 1 N/C

Contacts 1)

Oil impregnated bearing, needs no lubrication

Double break silver-to-silver contacts

Cast dustproof and weatherproof enclosure

Integrally cast mounting feet

Tapped conduit hole

Heavy duty toggle mechanism snap action

Malleable iron operating lever adjustable to any angular position

Plastic moulded cams

Notes: 1) Please state precise ohm value (1 to 50) when ordering. 2) Prices are per each (kit).

Price Schedule ‘B2’

2 - 20

2

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Safety controllers

Price Schedule 'B2'

Series SRM: Fail safe control unitMonitoring of E-stops, safety gate switches and Steute safety coded magnetic switches

0

Stop Cat.

SRM21RT2

Price $Cat. No.Safety Cat.Rating

4 2 N/C or

1 N/0 + 1 N/C

Sensor Config.

24 V DC

Voltage

2

Enabling paths

Auto/manual

Type reset

SRM21RT2

NSC02DB24DA

Series NSC: Fail safe control unitMonitoring of safety gate switches and Carlo Gavazzi safety coded magnetic switches

0

0

Stop Cat.

NSC13DB24DA

NSC13DB24DC

Price $Cat. No.Safety Cat.Rating

4

4

2 N/C or 1 N/C

2 N/C or 1 N/C

Sensor Config.

24 V AC / DC

24 V AC / DC

Voltage

3

3

Enabling paths

Auto/manual

Monitored

Type reset

Series MF1: Standstill monitor

-

Stop Cat.

MF1C

Price $Cat. No.Safety Cat.Rating

3 1 or 3 phase

Input Config.

24 V AC / DC

Voltage

2

Enabling paths

-

Type reset

MF1C

2 - 21

22

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘B2’

Limit switches - Pull wire (non safety)Heavy / Medium Duty 4 A (Ithe) IP 65

Aluminium die-cast body Protection class IP 65 Slow action 2 contacts Spring return (impulse)

Pull Wire Switch 4 A (Ithe) Non-emergency

ES41…

Heavy - Duty Protection class IP 65 Aluminium die-cast body Spring return (impulse)

Price $Cat. No.

TQ441010YU

Contacts

1 N/C+1 N/C

Pull Wire Switch 4 A (Ithe) Non-emergency

TQ441…

Price $Cat. No.

ES41Z 101S

Contacts

1 N/O+1 N/C

2 - 22

2

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Foot operated switchesType GF, GFS

Series GFM - 4 A (Ithe), Series GF - 16 A (Ithe)

- foot switches aluminium, IP 65 General purpose and heavy duty types

Foot switch (guarded)

GFS/GFSM…

Foot switch (unguarded)

GF/GFM…

Notes: 1) Please state precise ohm value (1 KΩ to 50 KΩ) when ordering. 2) Prices are per each (kit).

Series GFS : Safety foot switch

Price $Cat. No.

GFS1SD 10VD

GFS2SD 20VD

IPRating

IP 65IP 65

Contacts

1 N/O + 1 N/C2 N/O + 2 N/CGFS Safety foot switch

ActionUnguardedCat. No. Price $

GuardedCat. No.

Slow

Snap

Snap

Slow

Slow

Slow

Slow

Slow

Slow

/Description

1 Pedal, 1 N/O 1 N/C

1 Pedal, 1 N/O 1 N/C

1 pedal 2 N/O 2 N/C

1 pedal 2 N/O 2 N/C

1 Pedal, 1 N/O 1 N/C

with pressure point

(2 stage)

1 Pedal, with

potentiometer 1)

2 Pedal, 1 N/O 1 N/C

2 Pedal, 2 N/O 2 N/C

Explosion proof

300.00

320.00

360.00

330.00

570.00

670.00

570.00

680.00

700.00

Price $

340.00

345.00

400.00

415.00

580.00

740.00

620.00

850.00

790.00

GF 101S

GFM 101S

GFM 202S

GF 2O2S

GF 10SD10S

GF POTI_OHM

GF2 10S10S

GF2 20S20S

EEX GF1O1S

GFS 101S

GFSM 1O1S

GFSM 2O2S

GFS 202S

GFS 10SD10S

GFS POTI_OHM

GFS2 10S/10S

GFS2 20S/20S

EEX GFS1O1S

Replacement Contacts Cat. No. Price $

1x ES 60GF

1x ZS23211

2x EM 40 GF KIT

2x ES 40 GF KIT

1x ES 40GF KIT

-

2x ES 60 GF

2x ES 40 GF KIT

-

Price Schedule ‘B2’

2 - 23

22

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Pressure switchesGeneral purpose and industrial type

Pressure range

GPS series – General purpose (IP 54)Features

Wide selection of transducer wetted materials suitable for air, water, oil and for corrosive fluid Field adjustable set points and differential Internal components and bellows are treated and chrome plated to ensure long life Provided with single C/O snap-action switch 1) 20 mm cable entry

Price $ Pressure differentialAllowable pressure Cat. No.

GPS-B015-FN4-VD

GPS-B025-FN4-VD

GPS-B045-FN4-VD

IPS series – Industrial range (IP 65)Features

Wide selection of transducer wetted materials suitable for air, water, oil and corrosive fluid Field adjustable set points and differential IP 65 enclosure with 20 mm cable entry Set point repeatability, ±1 % of operating range One changeover snap-action switch 1) Every internal part and bellows of the switch is chrome plated and treated to ensure long life Mounting bracket is provided with switch for ease of installation

IPS-B026-FN4-VD

IPS-B036-FN4-VD

IPS-B046-FN4-VD

1.45

2.90

5.80

10

20

40

500

700

1000

72.5

101.45

145

2.90

3.60

4.35

20

25

30

400

400

600

58

58

87

217

217

217

1500

1500

1500

43.5

87

145

300

600

1000

-

-

14.5

0

0

100

36.2

50.72

65.2

250

350

450

7.25

8.7

11.6

50

60

80

217

217

217

1500

1500

1500

GPS-B025-FN4-VD

Notes: 1) AC rating 240 V, 10 A. DC rating 24 V, 3 A.

Minimumallowable

kPa psi

Maximumallowable

kPa psi

Minimumallowable

kPa psi

Maximum allowable

kPa psi

Maximum

kPa psi

Pressure range Price $ Pressure differentialAllowable pressure Cat. No.

Minimumallowable

kPa psi

Maximumallowable

kPa psi

Minimumallowable

kPa psi

Maximum allowable

kPa psi

Maximum

kPa psi

Selecting desired ‘cut-off’ and differential

Calculating differential pressure – e.g. IPS-B026-FN4-VD

Specifications 1 N/O + 1 N/C contacts Female NPT ¼” connection port Bellows material: PBP-3 (phosphor bronse) 90ºC

Price Schedule ‘B3’

3- 1

3 Soft starters and drives

Electronic soft starters product selection guide 3 - 2S+S

PCS - introduction, specifications and ordering details 3 - 4AuCom

CSX and CSXi - introduction, specifications and ordering details 3 - 7EMX3 - introduction, specifications and ordering details 3 - 12Variable Speed Drives

Product selection guide 3 - 23Santerno SINUS Nano range - introduction, standard specifications and ordering details 3 - 24SINUS Micro range - introduction, standard specifications and ordering details 3 - 25SINUS Nano and Micro ranges - options 3 - 26SINUS Penta range - introduction, standard specifications and options 3 - 27SINUS Penta - range and selection (380 - 415 V) 3 - 32Input and output choke - ordering details 3 - 35Semiconductor fuses and accessories - ordering details 3 - 36Brake resistor selection by duty cycle 3 - 37Brake resistors and accessories - ordering details 3 - 38Rating and selection chart 3 - 40SINUS Penta - range and selection (660 - 690 V) 3 - 44SINUS Penta - multi-pump application and regenerative application 3 - 46SINUS Penta - options 3 - 48SINUS Penta - specifications 3 - 49

TTTSSSSSSSSOOOOOOOOOFFFFFFFFFTTTTTTTTTTTTTT SSSTTTAAARRTTEEERSSSSSS

SINUS SS NANOVARIABLE SPEED DRIIVVEE

SSSSIIINNNNUUUUSSSS SSSSSS MMMIICCRROOVVVAAARRRIIIAAAABBBBLLLEEE SSSPPPPEEEEEEEEDDDD DDDDRRRRIIIVVVVEEE

SSSIIINNNUUUSSS PPPEEENTAVVVAAARRRIIIAAABBBLLLEEE SSSPPPEEEEEEDDD DDDRRRIIIVVVEEESSSOOOFFFTTT SSSSSOOOOOOOOOOFFFFFFFTTTTTTT SSSTTTAAARRRTTTEEERRRSSSSSSSSSSTTTT

3 - 2

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Soft startersProduct selection guide

Introduction

NHP offers an extensive range of soft starter products to ensure your technical and commercial objectives are easily satisfied. The following table provides an overview of the features available from each model and an indication of the duty cycles (Light, Medium, Heavy & Severe) that the products are suited to. When used in conjunction with the table on page 3 - 3, accurate soft starter selection for your intended application is assured.

Note: 1) Optional extra

Power range

Voltage range

Strategy

Controlled

phases

Utilisation

category

User

adjustment

Start modes

Stop modes

Protection

Outputs

Inputs

Indication

Sundry

Applications

(Refer page 3-3)

Page

reference

1.1 - 45 kW, 3 wire2.2 - 75 kW, 6 wire200 - 480 V AC

Closed loop,controlled current

3

AC 53b,built-in bypass

DIP switch

Timed voltage ramp Current limitKick-start

Soft stop

Overload c/w adj. trip classPhase imbalancePhase sequenceLine fault/open loadStarter over-tempShorted SCR

1 x Fixed1 x Programmable1 x Optional

1 x Start1 x Stop

1 Flash coded LED

Various accessories tointegrate with S+Sswitchgear products 1)

Light & Medium dutyHeavy duty with derating

3 - 4

CSXi

7.5 - 110 kW, 3 wire

200 - 440 V AC

Closed loop,controlled current

2 with Equi-Vec TM

AC 53b,built-in bypass

Rotary switch

Constant current Timed current ramp

Soft stop

Overload c/w adj. trip classMotor thermistorExcess start timePhase imbalancePhase sequenceLine fault/open loadShorted SCRComms error

1 x Fixed1 x Programmable

1 x Start1 x Stop

2 Flash coded LEDs

Remote operator 1)Modbus module 1)DeviceNet Module 1)Profibus Module 1)Semiconductor fuses1)

Light, Medium &Heavy duty

3 - 9

CSX

7.5-110 kW, 3 wire

200 - 440 V AC

Open loop,controlled voltage

2 with Equi-Vec TM

AC 53b,built-in bypass

Rotary switch

Timed voltage ramp

Soft stop

Line fault/open load Shorted SCRComms errorSupply frequency

1 x Fixed

1 x Start1 x Stop

2 Flash coded LEDs

Remote operator 1)Modbus module 1)DeviceNet Module 1)Profibus Module 1)Semiconductor fuses 1)

Light, Medium &Heavy duty

3 - 7

Cat No. PCS EMX3

7.5 - 800 kW, 3 wire11-1500 kW, 6 wire

200 - 440 V AC200 - 690 V AC 1)

Closed loop,controlled current

3

AC 53a, continuousAC 53b, bypassed

Digital keypad

XLR-8 adaptive accelerationConstant currentCurrent limitKick-start

XLR-8 adaptive decelerationTVR soft stopBrake mode

Overload c/w progthermal modelMotor thermistorExcess start timePhase imbalancePhase sequenceElectronic shearpinUnder-currentAux. trip inputLine fault/open loadStarter over-tempShorted SCRComms error

1 x Fixed3 x Programmable

1 x 4-20 mA Prog1 x Start1 x Stop1 x Reset2 x Programmable1 x PT 100

Multi-line plain Englishgraphical display

Simulation modesDual parameter setsTrip logEvent logStarts / hours counterAuto-stopEmergency run modeModbus, DeviceNet, Profibus, USB 1)Remote mount keypad 1)690 V AC 1)Semiconductor fuses 1)Expansion I/O 1)RTD/ Ground fault module 1)

Light, Medium, Heavy & Severe duty

3 - 12

3 - 3

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Soft startersApplications and duty cycle categories

Severe

Medium

Medium

Severe

Severe

Severe

Severe

Severe

Severe

Medium

Medium

Light

Medium

Heavy

Severe

Severe

Heavy

Heavy

Severe

Medium

Severe

Severe

Light

Heavy

Duty

Heavy

Heavy

Light

Severe

Severe

Severe

Heavy

Severe

Heavy

Severe

Medium

Heavy

Medium

Severe

Medium

Medium

Medium

Severe

Medium

Medium

Medium

Severe

Medium

Severe

Duty

Agitator

Atomiser

Bottle washer

Centrifuge

Chipper

Compressor - Recip (Loaded)

Compressor - Recip (Unloaded)

Compressor - Screw (Loaded)

Compressor - Screw (Unloaded)

Conveyor - Belt

Conveyor - Roller

Conveyor - Screw

Crusher - Cone

Crusher - Jaw

Crusher - Rotary

Crusher - Vertical impact

Debarker

Dryer

Dust collector

Edger

Fan - Axial (Damped)

Fan - Axial (Un-damped)

Fan - Centrifugal (Damped)

Fan - Centrifugal (Un-damped)

Application

Fan - High pressure

Grinder

Hydraulic power pack

Mill

Mill - Ball

Mill - Hammer

Mill - Roller

Mixer

Palletiser

Planer

Press

Pump - Bore

Pump - Centrifugal

Pump - Positive displacement

Pump - Slurry

Re-pulper

Rotary table

Sander

Saw - Bandsaw

Saw - Circular

Separator

Shredder

Slicer

Tumbler

Application

Electronic soft startersSoft starter ratings are influenced by several factors but none more so than the starting time and starting current characteristics of the driven machine. The following table, when used in conjunction with the ratings matrices provided on the following pages, ensures accurate soft starter selection.

Note: The above table is intended as a guide only. Individual machine and motor characteristics will determine the actual start current and start time requirements.

AC 53a: 3-10: 50-10

Duty cycle

50 = Ratio of ON/OFF time 50 %10 = Operating cycles per hour

Start condition

3 = 3 x FLC10 = 10 seconds

Example 1Continuous operation

AC 53b: 3-10: 350

Example 2Bypassed operation

Category Continuous operation Bypassed operation

Light duty AC 53a: 3-10: 50-10 AC 53b: 3-10: 350

Medium duty AC 53a: 3.5-15: 50-10 AC 53b: 3.5-15: 345

Heavy duty AC 53a: 4-20: 50-10 AC 53b: 4-20: 340

Severe duty AC 53a: 4.5-30: 50-10 AC 53b: 4.5-30: 330

Duty category definition - Example

Time between ramps

350 = 350 seconds

Start condition

3 = 3 x FLC10 = 10 seconds

3 - 4

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Soft startersPCS series to 75 kW

PCS overviewThe PCS is a compact, simple to use soft starter product designed for 3 phase motors with ratings of up to 45 kW (3 wire) and 75 kW (6 wire).

Unlike competing compact soft starter products, the PCS controls all three phases to the motor, thereby further extending its application possibilities and minimising thermal stresses on the motor.

The basic PCS soft starter features built-in electronic motor protection with adjustable trip class together with a number of other motor and system protection functions. It also has a built-in bypass contactor, thus providing very low watts loss, smaller footprint dimensions, suitability for high density motor control panels and minimising installed cost.

The multiple starting and stopping modes offered by the PCS as standard make it suitable for a large variety of industrial applications.

The PCS is currently available in 2 voltage ranges, 200…480 V AC (stocked by NHP) and 200…600 V AC (available on indent basis) and are suitable for connection to 50 or 60 Hz supply systems.

Motor starting

PCS soft starters provide the user a selection of starting and stopping modes as standard. The ability to select and tailor the starting format ensures the full benefits of soft starting can be achieved in any industrial motor starting application.

Standard starting modesTimed voltage ramp

The timed voltage ramp soft start mode offered by the PCS has the most general application. User adjustments for initial torque and start ramp time allow the PCS to be configured for a variety of applications.

The initial torque can be adjusted from 15 % to 65 % of locked rotor torque. The start ramp time can be adjusted from 2 to 30 seconds.

Current limit

The current limit start mode is used when it is necessary to limit the maximum starting current.

The current limit setting can be adjusted to provide 150 %, 250 %, 350 % or 450 % of full load amps during start. The start time is also user adjustable from 2 to 30 seconds.

Note: If the motor is not up to speed after the selected time elapses, the PCS will transition to full voltage.

Kickstart

Kickstart

The kickstart function is intended for use on machines that present a high frictional starting characteristic. It provides a current pulse of 450 % FLC over a user adjustable period of 0 to 1.5 seconds, allowing the motor to develop the additional starting torque required to get the load moving.

Current limit

3 - 5

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Standard stopping modesSoft Stop

The soft stop function can be used to extend the stopping time of the motor and load. When enabled, the ramp down time can be set to either once, twice or three times the start ramp time setting.

The motor will stop when the output voltage from the PCS reaches the point where the load torque is greater than the motor torque.

PCS protection functionsElectronic motor overload protection with user

selectable trip class

The PCS soft starter provides electronic motor overload protection with adjustable trip class and automatic or manual reset selectivity as standard making it extremely versatile.

The motor full load current is user adjusted via a potentiometer located on the front panel. Overload trip class (either OFF, 10, 15 or 20 seconds) and automatic or manual reset operation are DIP switch selectable.

Note: The trip rating is 120 % of potentiometer setting.

Phase sequence protection

The PCS provides a user selectable (ON or OFF) phase sequence protection function as standard. When selected, the PCS will monitor the incoming phases before application of power to the motor.

Phase loss protection

The PCS provides phase loss protection as standard to ensure the motor will not attempt to start when there is a power phase missing. This protects the motor from burnout resulting from single phase starting conditions.

Open circuit output/open load protection

The PCS monitors the motor circuit to ensure the motor is connected throughout all phases of operation.

Phase imbalance protection

The PCS provides phase imbalance protection as standard. During run it continually monitors motor current through its internal current transformers. To prevent motor over-heating or damage, the PCS will trip if the phase imbalance exceeds specified limits.

Starter over-temperature protection

The PCS monitors the temperature of its power circuits (SCRs) by means of internal thermistors. When the maximum rated temperature of the power assembly is reached, the PCS switches off and a temperature fault is indicated via LED.

Shorted SCR protection

Prior to every start, the PCS will check the integrity of its power assembly (SCRs) and load connections to the motor. If the PCS detects a shorted SCR and/or open circuit on its output, the start will be aborted. This prevents damage from phase imbalance.

Fault indication

In all cases, when a fault is detected the PCS will trip in order to protect the motor and illuminate a fault LED. The fault LED is flash coded, to assist the user in identifying the trip cause thus simplifying the troubleshooting process.

PCS set-up procedureQuick and accurate set-up of the PCS is assured through a simple to use combination DIP switch selection panel and potentiometer.

Where only basic soft start and motor protection functionality is required, the user need only set the motor full load current.

PCS optional extrasAuxiliary contacts

The PCS provides 2 output relays as standard, one of which is programmable for instantaneous or up-to-speed operation. Should additional contacts be required, auxiliary contacts are available in a number of configurations.

Remote fault reset

Remote reset functionality can be achieved by installing a remote reset magnet onto the PCS. Reset magnets are available for all common AC control voltages.

Protective modules

Protective modules containing metal oxide varistors (MOVs) and snubber networks can be installed to protect the PCS against line transients and electrical noise.

PCS DIP

switch

selection

panel

Soft startersPCS series to 75 kW

3 - 6

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Soft startersPCS series - technical / ordering details

Catalogue Number construction The PCS is available in a variety of different formats to ensure individual user requirements are totally satisfied. Models stocked by NHP are those listed below. All other combinations are available on indent, POA.

PCS - 003 - 480V - 024

Three phase supply voltage

480V = 200 V AC - 480 V AC600V = 200 V AC - 600 V AC (Indent POA)

Product series designation

C = 3 wire, 6 wire motor connection

Current rating (3 wire)

Amps @ AC 53b:3.5-15:3585 Ambient temp. 50 °C, Altitude < 2000 m003 = 3 Amps, 009 = 9 Amps, 016 = 16 Amps, 019 = 19 Amps,025 = 25 Amps, 030 = 30 Amps, 037 = 37 Amps, 043 = 43 Amps,060 = 60 Amps, 085 = 85 Amps

Optional control supply

Blank = 100 V AC - 240 V AC024 = 24 V AC/DC

Notes: 1) Refer to PCS catalogue for starts/hour information. 2) Standard voltages 110 to 240 V AC 50/60 Hz. 3) When using the PCS in 6 wire mode, the overload current must be set to 58 % of the motor FLC. E.g. A 50 Amp motor in 6 wire

Ordering details

Price Schedule ‘A3’Opt. extras - Price Schedule ‘B4’

mode would use a PCS-030-480 V and the overload current setting would be set to 29 Amps.

PCS-PA-10

PCS-PA-20

PCS-PA-01

PCS-PA-11

PCS-23-CI23

PCS-37-CI37

PCS-25S-CC25

PCP-064-480V

PCP-147-480V

PCP-064-600V

PCP-147-600V

CMR7...V

PCV-064

Optional extrasAuxiliary contacts

Connection modules

Protective modules

Cooling fan

1 N/O contact

2 N/O contacts

1 N/C contact

1 N/O & 1 N/C contact

Connects PCS-003…019 to CA 7-9...23

Connects PCS-025…037 to CA 7-30...37

Connects PCS-003…025 to KT 7-25 S series breaker

480 V version suits all PCS models to 37 Amps

480 V version suits all PCS models 43 to 85 Amps

600 V version suits all PCS models to 37 Amps

600 V version for all models 43 to 85 Amps

Suits all PCS models 2)

Suits PCS models to 37 Amps

(Supplied as standard with PCS models 43 to 135 Amps)

Cat. No. Price $

Remote Reset Magnets

PCS starters are also available in enclosed format. Refer NHP for details.

PCS-003-480V

PCS-009-480V

PCS-016-480V

PCS-019-480V

PCS-025-480V

PCS-030-480V

PCS-037-480V

PCS-043-480V

PCS-060-480V

PCS-085-480V

890.00

910.00

980.00

1060.00

1230.00

1690.00

2020.00

2190.00

2600.00

3190.00

StandardCat. No.

PCS-003-480V-024V

PCS-009-480V-024V

PCS-016-480V-024V

PCS-019-480V-024V

PCS-025-480V-024V

PCS-030-480V-024V

PCS-037-480V-024V

PCS-043-480V-024V

PCS-060-480V-024V

PCS-085-480V-024V

24 V AC/DCControlCat. No.

Max. motor FLC3 Wire 6 Wire (A) (A)

Dimensions (mm)Height Width Depth

5.1

15

27

32

43

51

64

74

103

147

140

140

140

140

140

140

140

206

206

206

45

45

45

45

45

45

45

72

72

72

100

100

100

100

100

100

100

130

130

130

3

9

16

19

25

30

37

43

60

85

Overload 3) setting range (A) Price $

Ratings at 3.5 x FLC, 15 seconds 1)

1…3

3…9

5.3…16

6.3…19

8.3…25

10…30

12.3…37

14.3…43

20…60

28.3…85

Price $

Scan the QR code to view Motor

Control & Drives brochures.

3 - 7

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Soft startersCSX Series to 110 kW

CSX overviewThe CSX is a compact soft starter intended for use with 3 phase motors ranging from 7.5 to 110 kW at 400 V AC. Designed with the ‘first time’ soft start user in mind, the CSX incorporates a number of unique features aimed specifically at simplifying the installation and commissioning processes while also significantly reducing installed cost. In order to achieve this the CSX is provided with Equi-Vec™ balanced vector control technology and in-built bypass contactor.

In operation, the CSX provides smooth acceleration and deceleration of the motor and connected load, thereby minimising the electrical and mechanical stresses that would otherwise be encountered through the use of electromechanical motor starting methods.

Equi-Vec™ technology

Equi-Vec™ balanced vector control is state-of-the-art technology developed to enhance the performance of 2 phase soft start controllers. By balancing the current vectors during motor starting, the CSX is able to provide 3 phase like performance while maintaining the commercial and mechanical advantages normally associated with compact soft starter technology.

In-built bypass contactor

To further reduce installation complexity and cost the CSX is provided with an in-built bypass contactor as standard. This eliminates the need for purchase and installation of an external bypass contactor and/or the need to force ventilate the enclosure.

Standard starting modesTimed voltage ramp soft start

The timed voltage ramp start mode is ideally suited to those applications that exhibit a variable start torque requirement. It allows the user to program an initial start voltage and start ramp time to ensure electrical and mechanical stresses are minimised irrespective of motor loading.

CSX-007-V4-C1

Internal Bypass

Contactor

CSX set-up procedure

Quick and accurate set-up of the CSX is as simple as setting two rotary switches to deliver your preferred soft starting performance. For those applications that can benefit from soft stop, an additional rotary switch is provided.

CSX - 030 - V4 - C1

Control supply voltage

C1 = 110-240 V AC or 380-440 V ACC2 = 24 V AC/V DC (indent)

Three phase supply voltage

V4 = 200-440 V ACV6 = 200-575 V AC

Nominal motor kW rating @ 400 V AC

E.g. 007 = 7.5 kW, 110 = 110 kW

Catalogue Number construction

Time voltage ramp soft stop

Standard stopping modesTimed voltage ramp soft stop

During soft stop, the CSX gradually decreases output voltage over a user selected ramp time enabling driven machines to be stopped gently. This is of particular advantage in applications where machinery and/or product are adversely affected by sudden stopping. Examples include pumps and conveyors.

Notes: The soft stop feature can be disabled by selecting a ‘0’ stop time. The soft start and soft stop ramp times are independently adjustable.

Protection features

The CSX also offers an essential level of protection against; Power circuit faults Supply frequency faults Communications failure faults

3 - 8

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Soft startersCSX Series - technical / ordering details

Optional accessories

Remote operator

The RCM-02 is an IP 54 rated remote operator / display unit that allows the user to control and monitor CSX operations from a remote location.

Note: The RCM-02 connects to the CSX via the optional interface module PIM-RZ-01.

Fieldbus connectivity

A selection of fieldbus protocol gateways is available for the CSX thereby enabling connection to your preferred communication network.

Pump application interfaceThe pump application interface connects to the side of the CSX soft starter and provides enhanced functionality in pumping applications. Features include; Low pressure input, high pressure input, low water level input, a PT100 input and common fault relay. The digital inputs are assignable to normally open or normally closed whilst the PT100 input offers selectable trip temperature.

RCM-02

CSX soft starters are also available in enclosed format. Consult your nearest

NHP office for pricing and availability.

Finger guards for models 075-110

Fast acting semiconductor fuses (400 V AC applications, 3 required per starter)

For model CSX-007

For model CSX-015

For models CSX-018 and CSX-022

For model CSX-030

For models CSX-037 to CSX-055

For model CSX-075

For models CSX-090 and CSX-110

Semiconductor fuse holders (1 holder per fuse)

For 170M1314 to 170M1322

For 170M3022

Fieldbus communications modules

DeviceNet

Modbus

Profibus

Pump Application interface

Remote operator panel - CSX Remote operator/fault display unit

- Remote operator interface module

Price $

9950350300A

170M1314

170M1317

170M1318

170M1319

170M1321

170M1322

170M3022

170H1007

170H3003

PIM-DN-01

PIM-MB-01

PIM-PB-01

PIM-PA-01

RCM-02

PIM-RZ-01

Cat. No.Optional extras

Price Schedule ‘B3’

980.00

1180.00

1270.00

1370.00

1630.00

1700.00

1990.00

2120.00

2360.00

2870.00

3180.00

Price $

CSX-007-V4-C1

CSX-015-V4-C1

CSX-018-V4-C1

CSX-022-V4-C1

CSX-030-V4-C1

CSX-037-V4-C1

CSX-045-V4-C1

CSX-055-V4-C1

CSX-075-V4-C1

CSX-090-V4-C1

CSX-110-V4-C1

StandardCat. No.

Ordering detailsCurrent ratings based on 10 starts/hour equally spaced, 45 ºC, 3 wire motor connection.

Price $

CSX-007-V4-C2

CSX-015-V4-C2

CSX-018-V4-C2

CSX-022-V4-C2

CSX-030-V4-C2

CSX-037-V4-C2

CSX-045-V4-C2

CSX-055-V4-C2

CSX-075-V4-C2

CSX-090-V4-C2

CSX-110-V4-C2

Light duty3 x FLC, 10 sec

Medium duty3.5 x FLC, 15 sec Depth

24 V AC/DC ControlCat. No.

22

42

51

57

60

84

96

100

161

190

200

18

34

42

46

57

68

77

100

127

151

175

163

163

163

163

163

191

191

191

212

212

212

Heavy duty4 x FLC, 20 sec

16

29

35

38

47

57

63

82

103

123

143

Height Width

203

203

203

203

203

215

215

215

240

240

240

98

98

98

98

98

145

145

145

202

202

202

Dimensions (mm)

3 - 9

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Soft startersCSXi Series to 110 kW

CSXi overviewThe CSXi is a compact closed loop controlled current soft starter intended for use with 3 phase motors ranging from 7.5 to 110 kW at 400 V AC. Designed with the ‘first time’ soft start user in mind, the CSXi incorporates a number of unique features aimed specifically at simplifying the installation and commissioning processes while also significantly reducing installed cost. In order to achieve this the CSXi is provided with Equi-Vec™ balanced vector control technology, a comprehensive array of motor and system protection features including in-built bypass contactor and in-built thermal overload with adjustable trip class, all as standard.

In operation, the CSXi provides smooth acceleration and deceleration of the motor and connected load, thereby minimising the electrical and mechanical stresses that would otherwise be encountered through the use of electromechanical motor starting methods.

Equi-Vec™ technology

Equi-Vec™ balanced vector control is state-of-the-art technology developed to enhance the performance of 2 phase soft start controllers. By balancing the current vectors during motor starting, the CSXi is able to provide 3 phase like performance while maintaining the commercial and mechanical advantages normally associated with compact soft starter technology.

In-built motor & system protection

The CSXi provides a comprehensive array of motor and system protection features to further satisfy the most demanding of industrial motor control applications. This eliminates the need to purchase/install additional devices, thus acting to reduce installed cost.

In-built protection features are summarised as follows;

Motor overload (adjustable thermal model) Phase loss / imbalance Excess start time Phase sequence / rotation Motor thermistor input Power circuit fault (shorted SCR, supply fault) Supply frequency Communications failure Trip contact LED healthy / fault indicators

In-built bypass contactor

To further reduce installation complexity and cost the CSXi is provided with in-built bypass contactor as standard. This eliminates the need for external bypass contactors and/or the need to force ventilate enclosures.

Standard starting modesConstant current/current limit soft start

The constant current start mode is ideally suited to highly inertial applications. Due to the nature of this starting mode highly inertial loads are brought up to speed in the shortest time possible, thereby minimising thermal stresses on the motor.

CSXi-007-V4-C1

Timed current ramp soft start

The timed current ramp start mode allows the user to set minimum starting current, maximum starting current and a start ramp time. This method of starting is proven in applications that present a variable starting torque requirement, for example a conveyor that at times may start fully loaded and at other times will be lightly loaded, or to extend the start time of loads that easily break away.

Constant current

Current ramp

3 - 10

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Soft startersCSXi Series to 110 kW

Standard stopping modesTimed voltage ramp soft stop

During soft stop, the CSXi gradually decreases output voltage over a user selected ramp time enabling driven machines to be stopped gently. This is of particular advantage in applications where machinery and or product can be adversely affected by sudden stopping. Examples include pumps and conveyors.

Notes: The soft stop feature can be disabled by selecting a ‘0’ stop

time. The soft start and soft stop ramp times are independently

adjustable.

Protection features further explainedElectronic motor overload protection with user

adjustable motor thermal model.

The CSXi soft starter provides built-in motor overload protection with adjustable thermal model as standard.

The thermal model allows the user to select the tripping curve which most closely resembles the thermal withstand curve of the connected motor. This eliminates nuisance motor overload tripping, while maximising machine up-time and plant productivity.

User adjustable Motor FLC and thermal model via rotary switches located on the front panel.

Motor thermistor protection

In order to further enhance motor protection, the CSXi provides an input for direct connection of your motor thermistors.

Phase imbalance protection

The CSXi offers phase imbalance protection as standard. During both start and run, the CSXi monitors motor current through its internal current transformers. In order to prevent motor damage, burn out or over heating, the CSXi will trip if an imbalance exceeds specified limits or a phase loss occurs.

Power circuit protection

Prior to the application of power to the motor but following a start command, the CSXi monitors its line and load connection and the integrity of its SCRs. Should any abnormality be detected, the CSXi will trip thus ensuring the motor is not compromised.

Excess start time protection

The CSXi will trip if the starting time exceeds the motor’s safe starting time characteristics, ensuring the motor is not subjected to high currents for an excessive period of time. This feature will also ensure the load is not jammed or too large at start up.

Supply frequency error

The supply frequency during start and run may vary under some conditions including generator power situations. The CSXi monitors supply frequency to ensure that it is not operating outside its design parameters thus preventing damage to itself and the motor.

Phase sequence protection

Phase sequence protection is of particular advantage in applications that are rotation direction sensitive such as pumps, compressors etc. The CSXi will monitor the incoming phase rotation before application of power to the motor to prevent incorrect rotation of the motor. This feature is user configurable to fwd or any phase sequence application.

Communications failure

Automated plants utilise the communications features of the CSXi. Connection integrity is vital to maintain control and protection of the motor. The CSXi monitors the communications link to maintain supervisory control and displays a fault when a break occurs.

CSXi Set-up

Although the CSXi offers broad functionality, set-up is a simple process. A series of clearly labelled rotary switches is provided to ensure accurate and repeatable settings are easily made. Simply rotate these to the desired position (no need for a user manual) and you’re ready to go.

Fault & status information

Fault and status information is provided by on-board ‘flash coded’ LEDs. In addition, the RCM-02 remote operator is available for those who may require/benefit from remote control and monitoring.

CSXi - 030 - V4 - C1

Control supply voltage

C1 = 110-240 V AC or 380-440 V ACC2 = 24 V AC/V DC (indent)

Three phase supply voltage

V4 = 200-440 V ACV6 = 200-575 V AC

Nominal motor kW rating @ 400 V AC

E.g. 007 = 7.5 kW, 110 = 110 kW

Catalogue Number construction

Soft stop

3 - 11

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Soft startersCSXi Series - technical / ordering details

Optional accessoriesRemote operator

The RCM-02 is an IP 54 rated remote operator / display unit that allows the user to control and monitor CSXi operations from a remote location.

Note: The RCM-02 connects to the CSXi via the optional interface module PIM-RZ-01.

Fieldbus connectivity

A selection of Fieldbus protocol gateways is available for the CSXi thereby enabling connection to your preferred communication network.

Pump application interface

The pump application interface connects to the side of the CSXi soft starter and provides enhanced functionality in pumping applications. Features include; Low pressure input, high pressure input, low water level input, a PT100 input and common fault relay. The digital inputs are assignable to normally open or normally closed whilst the PT100 input offers selectable trip temperature. RCM-02

CSXi Soft starters are also available in enclosed format.

Consult your nearest NHP office for pricing and availability.

Finger guards for models 075-110

Fast acting semiconductor fuses (400 V AC applications, 3 required per starter)

For model CSXi-007

For model CSXi-015

For models CSXi-018 and CSXi-022

For model CSXi-030

For models CSXi-037 to CSXi-055

For model CSXi-075

For models CSXi-090 and CSXi-110

Semiconductor fuse holders (1 holder per fuse)

For 170M1314 to 170M1322

For 170M3022

Fieldbus communications modules

DeviceNet

Modbus

Profibus

Pump Application interface

Remote operator panel - Remote operator/fault display unit

Remote operator interface module

Price $

9950350300A

170M1314

170M1317

170M1318

170M1319

170M1321

170M1322

170M3022

170H1007

170H3003

PIM-DN-01

PIM-MB-01

PIM-PB-01

PIM-PA-01

RCM-02

PIM-RZ-01

Cat. No.Optional extras

Price Schedule ‘B3’

1470.00

1870.00

2050.00

2120.00

2350.00

2620.00

2830.00

2980.00

3150.00

4050.00

4260.00

Price $

CSXI-007-V4-C1

CSXI-015-V4-C1

CSXI-018-V4-C1

CSXI-022-V4-C1

CSXI-030-V4-C1

CSXI-037-V4-C1

CSXI-045-V4-C1

CSXI-055-V4-C1

CSXI-075-V4-C1

CSXI-090-V4-C1

CSXI-110-V4-C1

StandardCat. No.

Ordering detailsCurrent ratings based on 10 starts/hour equally spaced, 45 ºC, 3 wire motor connection.

Price $

CSXI-007-V4-C2

CSXI-015-V4-C2

CSXI-018-V4-C2

CSXI-022-V4-C2

CSXI-030-V4-C2

CSXI-037-V4-C2

CSXI-045-V4-C2

CSXI-055-V4-C2

CSXI-075-V4-C2

CSXI-090-V4-C2

CSXI-110-V4-C2

Light duty3 x FLC, 10 sec

Medium duty3.5 x FLC, 15 sec Depth

24 V AC/DC ControlCat. No.

18

34

42

48

60

75

85

100

140

170

200

18

34

42

46

57

68

77

100

127

151

175

163

163

163

163

163

191

191

191

212

212

212

Heavy duty4 x FLC, 20 sec

16

29

35

38

47

57

63

82

103

123

143

Height Width

203

203

203

203

203

215

215

215

240

240

240

98

98

98

98

98

145

145

145

202

202

202

Dimensions (mm)

3 - 12

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

OverviewThe EMX3 is an advanced digital soft start solution for motors from 7.5 kW to 1500 kW. EMX3 soft starters provide a complete range of motor and system protection features and have been designed for reliable performance in the most demanding installation situations.

Motor startingThe EMX3 puts you truly in control of motor starting. Depending on your application requirements you can select between the two best soft start control methods. For applications requiring precise control of motor start current EMX3 offers a choice of Constant Current or Current Ramp start modes. Or for superior control over acceleration or deceleration choose XLR-8 Adaptive Acceleration Control.

Standard starting modesXLR-8

XLR-8 adaptive acceleration control is a new intelligent motor control technique developed by AuCom. In an XLR-8 soft start, the EMX3 adjusts the current in order to start the motor within a specified time and using a selected acceleration profile.Every application has a particular starting profile, based on characteristics of the load and motor. XLR-8 offers three different starting profiles, to suit the requirements of different applications. Selecting an XLR-8 profile that matches the inherent profile of the application can help smooth out acceleration across the full start time. Selecting a dramatically different XLR-8 profile can somewhat neutralise the inherent profile. For example, using a late cubic profile to start an early cubic application will result in a more linear behaviour.

XLR-8 start profile

Early acceleration Constant acceleration Late acceleration Start ramp time

Constant current

Constant current is the traditional form of soft starting, which raises the current from zero to a specified level and keeps the current stable at that level until the motor has accelerated. Constant current starting is ideal for applications where the start current must be kept below a particular level.

Soft starters EMX3 for motors to 1500 kW @ 400 V AC and 690 V AC

Refer catalogue EMX3

Time

100

90

80

70

60

50

40

30

20

10

0

1

2

3

4

XLR-8 Adaptive acceleration control

Constant current

Kickstart

Current ramp

Timed current ramp

Current ramp soft starting raises the current from a specified starting level to a maximum limit, over an extended period of time. Current ramp starting can be useful for applications where:

The load can vary between starts (for example a conveyor which may start loaded or unloaded). Set the initial current to a level that will start the motor with a light load, and the current limit at a level that will start the motor with a heavy load.

The load breaks away easily, but starting time needs to be extended (for example a centrifugal pump where pipeline pressure needs to build up slowly).

The electricity supply is limited (for example a generator set), and a slower application of load will allow greater time for the supply to respond.

Kickstart

Kickstart provides a short boost of extra torque at the beginning of a start, and can be used in conjunction with current ramp or constant current starting. Kickstart can be useful to help start loads that require high breakaway torque but then accelerate easily (for example flywheel loads such as presses).

1

2

3

4

3 - 13

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Soft starters EMX3 series overview

Brake

When brake is selected, the EMX3 uses DC injection to slow the motor.

The EMX3 braking:• Does not require the use of a DC brake contactor• Controls all three phases so that the braking currents and

associated heating is evenly distributed through the motor.Braking has two stages: 1. Pre-brake: provides an intermediate level of braking to slow

motor speed to a point where full brake can be operated successfully (approximately 70 % speed).

2. Full brake: brake provides maximum braking torque but is ineffective at speeds greater than approximately 70 %.

Standard stopping modesXLR-8 Adaptive deceleration control

In an XLR-8 soft stop, the EMX3 controls the current in order to stop the motor within a specified time and using a selected deceleration profile. XLR-8 can be useful in extending the stopping time of low interia loads. Every application has a particular stopping profile, based on characteristics of the load and the motor. XLR-8 offers three different stopping profiles.

TVR Soft Stop

Braking

Time

100

90

80

70

60

50

40

30

20

10

0

1

23

4

XLR-8 Adaptive deceleration control

Choose the XLR-8 profile that best matches your application requirements.XLR-8 stop profile:

Early deceleration Constant deceleration Late deceleration Stop time

TVR soft stop

Timed voltage ramp reduces the voltage to the motor gradually over a defined time. The load may continue to run after the stop ramp is complete. Timed voltage ramp stopping can be useful for applications where the stop time needs to be extended, or to avoid transients on generator set supplies.

Standard protectionMotor thermal model

The EMX3 will verify whether the motor has sufficient thermal capacity for a successful start. The soft starter compares the motor’s temperature rise from the last motor start and only operates if the motor is cool enough to start successfully.

Excess start time

Excess start time is the maximum time the EMX3 will attempt to start the motor. If the motor does not reach full speed within the programmed limit, the starter will trip indicating a stalled condition.

Electronic shearpin protection

With electronic shearpin or instantaneous overcurrent protection the EMX3 can be configured to trip if the average current of all three phases exceeds a specified level while the motor is running. This would usually occur in a ‘stall’ or ‘locked rotor’ condition.

Undercurrent

The soft starter can be configured to trip if the average current of all three phases drops below a specified level while the motor is running. This undercurrent or under-load is usually indicative of a broken coupling between the motor and driven machine, a broken conveyer belt, loss of product or a dry pump.

Mains frequency

The EMX3 monitors mains frequency throughout operation, and can be configured to trip if the frequency varies beyond a specified tolerance.

Phase sequence

This feature selects which phase sequences the soft starter will allow at a start. During its pre-start checks, the starter examines the sequence of the phases at its input terminals and trips if the actual sequence does not match the selected option.

1

2

3

4

3 - 14

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Soft starters EMX3 series overview

Current imbalanceThe EMX3 can be configured to trip if the currents on the three phases vary from each other by more than a specified amount. The imbalance is calculated as the difference between the highest and lowest currents on all three phases, as a percentage of the highest current.

Auxiliary input tripAuxiliary input trip allows the connection of external fault detection devices, such as low pressure or no flow detectors, vibration sensors, etc.

Motor thermistor inputThe EMX3 has provisions for motor thermistor input and is able to detect excessive temperature in the motor windings generally caused by a stall or from inadequate ventilation.

RS 485 failureThe EMX3’s serial link is provided with a user adjustable time-out function which will trip if the maximum allowable period of RS 485 serial inactivity has been exceeded.

Optional protection functionsGround fault

The optional Ground fault/ RTD card allows the user to configure the soft starter to trip if ground fault exceeds a specified level while the motor is running. Ground fault is a dynamic trip based on phase current measurements every half-cycle.

RTD inputsThe optional Ground fault/RTD card allows the user to connect up to six PT100 RTD directly to the EMX3. This feature enables the EMX3 to measure the temperature of the RTDs and trip if overheating is detected. Trip levels are user programmed.

EMX3 specialist featuresGraphical display

In many cases we’ve done away with language altogether, using real-time graphs of motor operating performance and current to quickly and clearly illustrate exactly how your motor is performing.

Quick start set-upThe EMX3 has been designed for ease of use, and the user-friendly menu is no exception. A quick setup guide helps you configure the starter for common applications by suggesting a typical setting, which you can then fine tune to suit your needs.

Real language in real timeThe EMX3 gives real-language feedback messages instead of the usual alarm codes. With real-time metering displays and a 99-place event log recording time-stamped details of operation and performance, it has never been easier to track how your motor is behaving.

Remote mounting keypadControl pushbuttons, fault and status information available from the EMX3 can be brought out to the cubicle door via the remote mounting keypad option.

Metering and monitoringEMX3 delivers an extensive range of information to replace an additional powermeter. These include motor temperature, current data, motor power, last start information, date and time, performance graph, SCR conduction, trip log and the user-programmable screen.

3 - 15

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Soft starters EMX3 series overview

SimulationsThe EMX3 simulation functions let you test the soft starter’s operation, external control circuits and associated equipment without connecting the soft starter to line voltage or a motor. The EMX3 has three simulation modes:Run simulation: simulates a motor starting, running and stopping to ensure correct installation.Protection simulation: simulates activation of each protection mechanism to confirm correct protection response.Signaling simulation: simulates output signaling.

Emergency run operationEmergency Run is controlled by a two wire circuit connected to Input A (terminals C53-C54). Closing Input A causes the EMX3 to run the motor and ignore user specified trip conditions. This is useful when the cost of lost production out-weighs the potential cost of further equipment damage.

Unique wiring loomUsing the EMX3’s unique and flexible cable ways, cables can be efficiently organised for wiring from either the top, left or from below.

Removable terminal blocksInstallation is easy with plug-in control terminal blocks, simply unplug each block, complete the wiring and re-insert the block.

Adjustable power terminalsThe bus bars on models EMX3-0360C ~ EMX3-1600C can be adjusted for top and bottom input and output giving four options to ease installation. This flexibility allows you optimisation of your switchboard layout.

In addition, internally bypassed models EMX3-0350B - EMX3-1000B have input and output busbars at both the top and the bottom of the unit. The busbars do not need to be adjusted.

Optional accessoriesOptional accessories for the EMX3 include the following:

Communication modules enabling the soft starter to be controlled by protocols such as DeviceNet™, ProfiBus® and Modbus RTU

USB module enables communication between your PC and EMX3 via Win-Master software. Win-Master is available free of charge.

I/O cards giving an added 2 x inputs, 3 x relay outputs, 1 x analogue input and 1 x analogue output.

RTD and Ground fault card providing 6 x PT100 RTD inputs 1 x ground fault input

Catalogue Number constructionThe EMX3 is available with a variety of options and formats to ensure individual user’s requirements are met. Models stocked by NHP are listed on the following 2 pages and all other combinations are available on indent, POA.

EMX3 – 0255 B – V4 – C1 – H

Keypad

H = Keypad fitted

Control voltage

C1 = 110-220 V AC & 230-440 V ACC2 = 24 V AC/DC

Three phase supply voltage

V4 = 200 V AC – 440 V ACV7 = 400 V AC – 690 V AC (indent)

Bypass

B = Internally BypassedC = Non-bypassed (indent)

Nominal current rating

Product series designation

Expansion input/

output card

6 way RTD and

ground fault

protection card

Communication

modules

3 - 16

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘B3’

Soft StartersEMX3 maximum motor FLC ratings 2)3 wire - 400 / 415 V AC applications 1)

Light

Duty

3 x FLC,

10 sec

Medium

Duty

3.5 x FLC,

15 sec

Heavy

Duty

4 x FLC,

20 sec

Severe

Duty

4.5 x FLC,

30 sec

Frame

size

110-440 V AC Control

Standard Model 3)

Cat. No. Price $

24 V AC/DC Control

Variant Model

Cat. No. Price $

AC 53b: Internal bypass contactor

23 A 20 A 17 A 15 A G1B EMX3-0023B-V4-C1-H 2550.00 EMX3-0023B-V4-C2-H

43 A 37 A 31 A 26 A G1B EMX3-0043B-V4-C1-H 2870.00 EMX3-0043B-V4-C2-H

50 A 44 A 37 A 30 A G1B EMX3-0050B-V4-C1-H 3120.00 EMX3-0050B-V4-C2-H

53 A 53 A 46 A 37 A G1B EMX3-0053B-V4-C1-H 3510.00 EMX3-0053B-V4-C2-H

76 A 64 A 55 A 47 A G1B EMX3-0076B-V4-C1-H 3690.00 EMX3-0076B-V4-C2-H

97 A 82 A 69 A 58 A G1B EMX3-0097B-V4-C1-H 4260.00 EMX3-0097B-V4-C2-H

100 A 88 A 74 A 61 A G1B EMX3-0100B-V4-C1-H 4610.00 EMX3-0100B-V4-C2-H

105 A 105 A 95 A 78 A G1B EMX3-0105B-V4-C1-H 4910.00 EMX3-0105B-V4-C2-H

145 A 123 A 106 A 90 A G2B EMX3-0145B-V4-C1-H 5610.00 EMX3-0145B-V4-C2-H

170 A 145 A 121 A 97 A G2B EMX3-0170B-V4-C1-H 5980.00 EMX3-0170B-V4-C2-H

200 A 189 A 160 A 134 A G2B EMX3-0200B-V4-C1-H 7160.00 EMX3-0200B-V4-C2-H

220 A 210 A 178 A 148 A G2B EMX3-0220B-V4-C1-H 7430.00 EMX3-0220B-V4-C2-H

255 A 231 A 201 A 176 A G3B EMX3-0255B-V4-C1-H 8650.00 EMX3-0255B-V4-C2-H

350 A 306 A 266 A 230 A G3B EMX3-0350B-V4-C1-H 11710.00 EMX3-0350B-V4-C2-H

425 A 371 A 321 A 276 A G3B EMX3-0425B-V4-C1-H 12720.00 EMX3-0425B-V4-C2-H

500 A 445 A 383 A 326 A G4B EMX3-0500B-V4-C1-H 14320.00 EMX3-0500B-V4-C2-H

580 A 492 A 425 A 364 A G4B EMX3-0580B-V4-C1-H 15700.00 EMX3-0580B-V4-C2-H

700 A 592 A 512 A 438 A G4B EMX3-0700B-V4-C1-H 16510.00 EMX3-0700B-V4-C2-H

820 A 705 A 606 A 516 A G4B EMX3-0820B-V4-C1-H 20620.00 EMX3-0820B-V4-C2-H

920 A 804 A 684 A 571 A G4B EMX3-0920B-V4-C1-H 23830.00 EMX3-0920B-V4-C2-H

1000 A 936 A 796 A 664 A G4B EMX3-1000B-V4-C1-H 25650.00 EMX3-1000B-V4-C2-H

AC 53a: Continous operation (no internal bypass) 4)

255 A 222 A 195 A 171 A G3C EMX3-0255C-V4-C1-H 8130.00 EMX3-0255C-V4-C2-H

360 A 351 A 303 A 259 A G4C EMX3-0360C-V4-C1-H 9180.00 EMX3-0360C-V4-C2-H

380 A 380 A 348 A 292 A G4C EMX3-0380C-V4-C1-H 9320.00 EMX3-0380C-V4-C2-H

430 A 413 A 355 A 301 A G4C EMX3-0430C-V4-C1-H 12040.00 EMX3-0430C-V4-C2-H

620 A 614 A 515 A 419 A G4C EMX3-0620C-V4-C1-H 16020.00 EMX3-0620C-V4-C2-H

650 A 629 A 532 A 437 A G4C EMX3-0650C-V4-C1-H 16980.00 EMX3-0650C-V4-C2-H

790 A 790 A 694 A 567 A G4C EMX3-0790C-V4-C1-H 20790.00 EMX3-0790C-V4-C2-H

930 A 930 A 800 A 644 A G4C EMX3-0930C-V4-C1-H 23390.00 EMX3-0930C-V4-C2-H

1200 A 1200 A 1135 A 983 A G5C EMX3-1200C-V4-C1-H 24910.00 EMX3-1200C-V4-C2-H

1410 A 1355 A 1187 A 1023 A G5C EMX3-1410C-V4-C1-H 28410.00 EMX3-1410C-V4-C2-H

1600 A 1600 A 1433 A 1227 A G5C EMX3-1600C-V4-C1-H 31190.00 EMX3-1600C-V4-C2-H

Notes: 1) Representative image to aid soft starter product selection, does not constitute complete power circuit. 2) Ratings for models EMX3-0023B to EMX3-0053B are based on 10 starts per hour, equally spaced, 40 ºC

ambient. Ratings for models EMX3-0076B to EMX3-1000B and EMX3-0255C to EMX3-1600C are based on 6 starts per hour equally spaced, 40 ºC ambient.

3) Standard models with internal bypass contactor (EMX3-xxxxB) are generally stocked. 4) Intended for use in well vented enclosures and / or with external bypass contactor. Particularly suited to

applications with high overload trip class (>trip class 10) and those that may experience transient overload conditions as part of normal run time operation.

For application and duty category definitions refer to page 3 - 3. For 690 V AC applications refer to pages 3 - 18 and 3 - 19.

3 - 17

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘B3’

Light

Duty

3 x FLC,

10 sec

Medium

Duty

3.5 x FLC,

15 sec

Heavy

Duty

4 x FLC,

20 sec

Severe

Duty

4.5 x FLC,

30 sec

Frame

size

110-440 V AC Control

Standard Model 3)

Cat. No. Price $

24 V AC/DC Control

Variant Model

Cat. No. Price $

AC 53b: Internal bypass contactor

34 A 30 A 26 A 22 A G1B EMX3-0023B-V4-C1-H 2550.00 EMX3-0023B-V4-C2-H

64 A 59 A 51 A 44 A G1B EMX3-0043B-V4-C1-H 2870.00 EMX3-0043B-V4-C2-H

75 A 66 A 55 A 45 A G1B EMX3-0050B-V4-C1-H 3120.00 EMX3-0050B-V4-C2-H

79 A 79 A 69 A 55 A G1B EMX3-0053B-V4-C1-H 3510.00 EMX3-0053B-V4-C2-H

114 A 96 A 83 A 70 A G1B EMX3-0076B-V4-C1-H 3690.00 EMX3-0076B-V4-C2-H

145 A 123 A 104 A 87 A G1B EMX3-0097B-V4-C1-H 4260.00 EMX3-0097B-V4-C2-H

150 A 132 A 112 A 82 A G1B EMX3-0100B-V4-C1-H 4610.00 EMX3-0100B-V4-C2-H

157 A 157 A 143 A 117 A G1B EMX3-0105B-V4-C1-H 4910.00 EMX3-0105B-V4-C2-H

217 A 184 A 159 A 136 A G2B EMX3-0145B-V4-C1-H 5610.00 EMX3-0145B-V4-C2-H

255 A 217 A 181 A 146 A G2B EMX3-0170B-V4-C1-H 5980.00 EMX3-0170B-V4-C2-H

300 A 283 A 241 A 200 A G2B EMX3-0200B-V4-C1-H 7160.00 EMX3-0200B-V4-C2-H

330 A 315 A 268 A 223 A G2B EMX3-0220B-V4-C1-H 7430.00 EMX3-0220B-V4-C2-H

382 A 346 A 302 A 264 A G3B EMX3-0255B-V4-C1-H 8650.00 EMX3-0255B-V4-C2-H

525 A 459 A 399 A 345 A G3B EMX3-0350B-V4-C1-H 11710.00 EMX3-0350B-V4-C2-H

638 A 557 A 482 A 414 A G3B EMX3-0425B-V4-C1-H 12720.00 EMX3-0425B-V4-C2-H

750 A 668 A 575 A 490 A G4B EMX3-0500B-V4-C1-H 14320.00 EMX3-0500B-V4-C2-H

870 A 738 A 637 A 546 A G4B EMX3-0580B-V4-C1-H 15700.00 EMX3-0580B-V4-C2-H

1050 A 889 A 768 A 658 A G4B EMX3-0700B-V4-C1-H 16510.00 EMX3-0700B-V4-C2-H

1230 A 1058 A 910 A 774 A G4B EMX3-0820B-V4-C1-H 20620.00 EMX3-0820B-V4-C2-H

1380 A 1206 A 1026 A 857 A G4B EMX3-0920B-V4-C1-H 23830.00 EMX3-0920B-V4-C2-H

1500 A 1404 A 1194 A 997 A G4B EMX3-1000B-V4-C1-H 25650.00 EMX3-1000B-V4-C2-H

AC 53a: Continous operation (no internal bypass) 4)

382 A 346 A 302 A 264 A G3C EMX3-0255C-V4-C1-H 8130.00 EMX3-0255C-V4-C2-H

540 A 540 A 465 A 395 A G4C EMX3-0360C-V4-C1-H 9180.00 EMX3-0360C-V4-C2-H

570 A 570 A 539 A 449 A G4C EMX3-0380C-V4-C1-H 9320.00 EMX3-0380C-V4-C2-H

645 A 645 A 552 A 464 A G4C EMX3-0430C-V4-C1-H 12040.00 EMX3-0430C-V4-C2-H

930 A 930 A 810 A 651 A G4C EMX3-0620C-V4-C1-H 16020.00 EMX3-0620C-V4-C2-H

975 A 975 A 842 A 683 A G4C EMX3-0650C-V4-C1-H 16980.00 EMX3-0650C-V4-C2-H

1185 A 1185 A 1071 A 868 A G4C EMX3-0790C-V4-C1-H 20790.00 EMX3-0790C-V4-C2-H

1395 A 1395 A 1244 A 992 A G4C EMX3-0930C-V4-C1-H 23390.00 EMX3-0930C-V4-C2-H

1800 A 1800 A 1800 A 1606 A G5C EMX3-1200C-V4-C1-H 24910.00 EMX3-1200C-V4-C2-H

2115 A 2115 A 1979 A 1671 A G5C EMX3-1410C-V4-C1-H 28410.00 EMX3-1410C-V4-C2-H

2400 A 2400 A 2400 A 2030 A G5C EMX3-1600C-V4-C1-H 31190.00 EMX3-1600C-V4-C2-H

Soft StartersEMX3 maximum motor FLC ratings 2)6 wire - 400 / 415 V AC applications 1)

Notes: 1) Representative image to aid soft starter product selection, does not constitute complete power circuit. 2) Ratings for models EMX3-0023B to EMX3-0053B are based on 10 starts per hour, equally spaced, 40 ºC

ambient. Ratings for models EMX3-0076B to EMX3-1000B and EMX3-0255C to EMX3-1600C are based on 6 starts per hour equally spaced, 40 ºC ambient.

3) Standard models with internal bypass contactor (EMX3-xxxxB) are generally stocked. 4) Intended for use in well vented enclosures and / or with external bypass contactor. Particularly suited

to applications with high overload trip class (>trip class 10) and those that may experience transient overload conditions as part of normal run time operation.

For application and duty category definitions refer to page 3 - 3. For 690 V AC applications refer to pages 3 - 18 and 3 - 19.

Scan the QR code to view EMX3

brochure.

3 - 18

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘B3’

Soft StartersEMX3 maximum motor FLC ratings 2)3 wire - 690 V AC applications 1)

Light

Duty

3 x FLC,

10 sec

Medium

Duty

3.5 x FLC,

15 sec

Heavy

Duty

4 x FLC,

20 sec

Severe

Duty

4.5 x FLC,

30 sec

Frame

size

110-440 V AC Control

Standard Model 3)

Cat. No. Price $

24 V AC/DC Control

Variant Model

Cat. No. Price $

AC 53b: Internal bypass contactor

23 A 20 A 17 A 15 A G1B EMX3-0023B-V7-C1-H 2860.00 EMX3-0023B-V7-C2-H

43 A 37 A 31 A 26 A G1B EMX3-0043B-V7-C1-H 3210.00 EMX3-0043B-V7-C2-H

50 A 44 A 37 A 30 A G1B EMX3-0050B-V7-C1-H 3500.00 EMX3-0050B-V7-C2-H

53 A 53 A 46 A 37 A G1B EMX3-0053B-V7-C1-H 3910.00 EMX3-0053B-V7-C2-H

76 A 64 A 55 A 47 A G1B EMX3-0076B-V7-C1-H 4110.00 EMX3-0076B-V7-C2-H

97 A 82 A 69 A 58 A G1B EMX3-0097B-V7-C1-H 4740.00 EMX3-0097B-V7-C2-H

100 A 88 A 74 A 61 A G1B EMX3-0100B-V7-C1-H 5130.00 EMX3-0100B-V7-C2-H

105 A 105 A 95 A 78 A G1B EMX3-0105B-V7-C1-H 5490.00 EMX3-0105B-V7-C2-H

145 A 123 A 106 A 90 A G2B EMX3-0145B-V7-C1-H 6250.00 EMX3-0145B-V7-C2-H

170 A 145 A 121 A 97 A G2B EMX3-0170B-V7-C1-H 6640.00 EMX3-0170B-V7-C2-H

200 A 189 A 160 A 134 A G2B EMX3-0200B-V7-C1-H 7980.00 EMX3-0200B-V7-C2-H

220 A 210 A 178 A 148 A G2B EMX3-0220B-V7-C1-H 8300.00 EMX3-0220B-V7-C2-H

255 A 231 A 201 A 176 A G3B EMX3-0255B-V7-C1-H 9580.00 EMX3-0255B-V7-C2-H

350 A 306 A 266 A 230 A G3B EMX3-0350B-V7-C1-H 12610.00 EMX3-0350B-V7-C2-H

425 A 371 A 321 A 276 A G3B EMX3-0425B-V7-C1-H 12720.00 EMX3-0425B-V7-C2-H

500 A 445 A 383 A 326 A G4B EMX3-0500B-V7-C1-H 15580.00 EMX3-0500B-V7-C2-H

580 A 492 A 425 A 364 A G4B EMX3-0580B-V7-C1-H 17110.00 EMX3-0580B-V7-C2-H

700 A 592 A 512 A 438 A G4B EMX3-0700B-V7-C1-H 18350.00 EMX3-0700B-V7-C2-H

820 A 705 A 606 A 516 A G4B EMX3-0820B-V7-C1-H 22990.00 EMX3-0820B-V7-C2-H

920 A 804 A 684 A 571 A G4B EMX3-0920B-V7-C1-H 26190.00 EMX3-0920B-V7-C2-H

1000 A 936 A 796 A 664 A G4B EMX3-1000B-V7-C1-H 28010.00 EMX3-1000B-V7-C2-H

AC 53a: Continous operation (no internal bypass) 4)

255 A 222 A 195 A 171 A G3C EMX3-0255C-V7-C1-H 9010.00 EMX3-0255C-V7-C2-H

360 A 351 A 303 A 259 A G4C EMX3-0360C-V7-C1-H 10090.00 EMX3-0360C-V7-C2-H

380 A 380 A 348 A 292 A G4C EMX3-0380C-V7-C1-H 10220.00 EMX3-0380C-V7-C2-H

430 A 413 A 355 A 301 A G4C EMX3-0430C-V7-C1-H 13110.00 EMX3-0430C-V7-C2-H

620 A 614 A 515 A 419 A G4C EMX3-0620C-V7-C1-H 17280.00 EMX3-0620C-V7-C2-H

650 A 629 A 532 A 437 A G4C EMX3-0650C-V7-C1-H 18400.00 EMX3-0650C-V7-C2-H

790 A 790 A 694 A 567 A G4C EMX3-0790C-V7-C1-H 22630.00 EMX3-0790C-V7-C2-H

930 A 930 A 800 A 644 A G4C EMX3-0930C-V7-C1-H 25750.00 EMX3-0930C-V7-C2-H

1200 A 1200 A 1135 A 983 A G5C EMX3-1200C-V7-C1-H 28530.00 EMX3-1200C-V7-C2-H

1410 A 1355 A 1187 A 1023 A G5C EMX3-1410C-V7-C1-H 32810.00 EMX3-1410C-V7-C2-H

1600 A 1600 A 1433 A 1227 A G5C EMX3-1600C-V7-C1-H 36460.00 EMX3-1600C-V7-C2-H

Notes: 1) Representative image to aid soft starter product selection, does not constitute complete power circuit. 2) Ratings for models EMX3-0023B to EMX3-0053B are based on 10 starts per hour, equally spaced, 40 ºC

ambient. Ratings for models EMX3-0076B to EMX3-1000B and EMX3-0255C to EMX3-1600C are based on 6 starts per hour equally spaced, 40 ºC ambient.

3) Standard models with internal bypass contactor (EMX3-xxxxB) are generally stocked. 4) Intended for use in well vented enclosures and / or with external bypass contactor. Particularly suited

to applications with high overload trip class (>trip class 10) and those that may experience transient overload conditions as part of normal run time operation.

For application and duty category definitions refer to page 3 - 3. For 400/415 V AC applications refer to pages 3 - 16 and 3 - 17.

3 - 19

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Light

Duty

3 x FLC,

10 sec

Medium

Duty

3.5 x FLC,

15 sec

Heavy

Duty

4 x FLC,

20 sec

Severe

Duty

4.5 x FLC,

30 sec

Frame

size

110-440 V AC Control

Standard Model 3)

Cat. No. Price $

24 V AC/DC Control

Variant Model

Cat. No. Price $

AC 53b: Internal bypass contactor

34 A 30 A 26 A 22 A G1B EMX3-0023B-V7-C1-H 2860.00 EMX3-0023B-V7-C2-H

64 A 59 A 51 A 44 A G1B EMX3-0043B-V7-C1-H 3210.00 EMX3-0043B-V7-C2-H

75 A 66 A 55 A 45 A G1B EMX3-0050B-V7-C1-H 3500.00 EMX3-0050B-V7-C2-H

79 A 79 A 69 A 55 A G1B EMX3-0053B-V7-C1-H 3910.00 EMX3-0053B-V7-C2-H

114 A 96 A 83 A 70 A G1B EMX3-0076B-V7-C1-H 4110.00 EMX3-0076B-V7-C2-H

145 A 123 A 104 A 87 A G1B EMX3-0097B-V7-C1-H 4740.00 EMX3-0097B-V7-C2-H

150 A 132 A 112 A 82 A G1B EMX3-0100B-V7-C1-H 5130.00 EMX3-0100B-V7-C2-H

157 A 157 A 143 A 117 A G1B EMX3-0105B-V7-C1-H 5490.00 EMX3-0105B-V7-C2-H

217 A 184 A 159 A 136 A G2B EMX3-0145B-V7-C1-H 6250.00 EMX3-0145B-V7-C2-H

255 A 217 A 181 A 146 A G2B EMX3-0170B-V7-C1-H 6640.00 EMX3-0170B-V7-C2-H

300 A 283 A 241 A 200 A G2B EMX3-0200B-V7-C1-H 7980.00 EMX3-0200B-V7-C2-H

330 A 315 A 268 A 223 A G2B EMX3-0220B-V7-C1-H 8300.00 EMX3-0220B-V7-C2-H

382 A 346 A 302 A 264 A G3B EMX3-0255B-V7-C1-H 9580.00 EMX3-0255B-V7-C2-H

525 A 459 A 399 A 345 A G3B EMX3-0350B-V7-C1-H 12610.00 EMX3-0350B-V7-C2-H

638 A 557 A 482 A 414 A G3B EMX3-0425B-V7-C1-H 12720.00 EMX3-0425B-V7-C2-H

750 A 668 A 575 A 490 A G4B EMX3-0500B-V7-C1-H 15580.00 EMX3-0500B-V7-C2-H

870 A 738 A 637 A 546 A G4B EMX3-0580B-V7-C1-H 17110.00 EMX3-0580B-V7-C2-H

1050 A 889 A 768 A 658 A G4B EMX3-0700B-V7-C1-H 18350.00 EMX3-0700B-V7-C2-H

1230 A 1058 A 910 A 774 A G4B EMX3-0820B-V7-C1-H 22990.00 EMX3-0820B-V7-C2-H

1380 A 1206 A 1026 A 857 A G4B EMX3-0920B-V7-C1-H 26190.00 EMX3-0920B-V7-C2-H

1500 A 1404 A 1194 A 997 A G4B EMX3-1000B-V7-C1-H 28010.00 EMX3-1000B-V7-C2-H

AC 53a: Continous operation (no internal bypass) 4)

382 A 346 A 302 A 264 A G3C EMX3-0255C-V7-C1-H 9010.00 EMX3-0255C-V7-C2-H

540 A 540 A 465 A 395 A G4C EMX3-0360C-V7-C1-H 10090.00 EMX3-0360C-V7-C2-H

570 A 570 A 539 A 449 A G4C EMX3-0380C-V7-C1-H 10220.00 EMX3-0380C-V7-C2-H

645 A 645 A 552 A 464 A G4C EMX3-0430C-V7-C1-H 13110.00 EMX3-0430C-V7-C2-H

930 A 930 A 810 A 651 A G4C EMX3-0620C-V7-C1-H 17280.00 EMX3-0620C-V7-C2-H

975 A 975 A 842 A 683 A G4C EMX3-0650C-V7-C1-H 18400.00 EMX3-0650C-V7-C2-H

1185 A 1185 A 1071 A 868 A G4C EMX3-0790C-V7-C1-H 22630.00 EMX3-0790C-V7-C2-H

1395 A 1395 A 1244 A 992 A G4C EMX3-0930C-V7-C1-H 25750.00 EMX3-0930C-V7-C2-H

1800 A 1800 A 1800 A 1606 A G5C EMX3-1200C-V7-C1-H 28530.00 EMX3-1200C-V7-C2-H

2115 A 2115 A 1979 A 1671 A G5C EMX3-1410C-V7-C1-H 32810.00 EMX3-1410C-V7-C2-H

2400 A 2400 A 2400 A 2030 A G5C EMX3-1600C-V7-C1-H 36460.00 EMX3-1600C-V7-C2-H

Soft StartersEMX3 maximum motor FLC ratings 2)6 wire - 690 V AC applications 1)

Notes: 1) Representative image to aid soft starter product selection, does not constitute complete power circuit. 2) Ratings for models EMX3-0023B to EMX3-0053B are based on 10 starts per hour, equally spaced, 40 ºC

ambient. Ratings for models EMX3-0076B to EMX3-1000B and EMX3-0255C to EMX3-1600C are based on 6 starts per hour equally spaced, 40 ºC ambient.

3) Standard models with internal bypass contactor (EMX3-xxxxB) are generally stocked. 4) Intended for use in well vented enclosures and / or with external bypass contactor. Particularly suited

to applications with high overload trip class (>trip class 10) and those that may experience transient overload conditions as part of normal run time operation.

For application and duty category definitions refer to page 3 - 3. For 400/415 V AC applications refer to pages 3 - 16 and 3 - 17.

Scan the QR code to view EMX3

brochure.

3 - 20

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price $Cat. No.Optional extras

Soft starters EMX3 series technical / ordering details

Note: 1) Two parallel connected fuses required per phase. 2) Fuse selection is based on a 400 % FLC start for 20 seconds in conjunction with standard published starts

per hour, duty cycle, 40 °C ambient temperature and up to 1000 m altitude. For installations operating outside these conditions, consult NHP.

170H1007

170H3003

170H3004

Refer NHP

PIM-MB-01

PIM-MT-01

PIM-DN-01

PIM-PB-01

PIM-PN-01

PIM-EI-01

PIM-USB-01

995-04803-00

995-04804-00

995-08133-00

995-04938-00

995-06348-00

Fast acting semiconductor fuses (400/415 V AC applications) 1)

For model EMX3-0023B (3 required)

For model EMX3-0043B (3 required)

For models EMX3-0050B and EMX3-0053B (3 required)

For model EMX3-0076B (3 required)

For models EMX3-0097B to EMX3-0145B (3 required)

For models EMX3-0170B to EMX3-0220B (3 required)

For model EMX3-0255B (3 required)

For model EMX3-0350B (3 required)

For model EMX3-0425B (3 required)

For model EMX3-0500B (6 required)

For model EMX3-0580B (3 required)

For model EMX3-0700B (3 required)

For model EMX3-0820B (3 required)

For model EMX3-0920B (3 required)

For model EMX3-1000B (3 required)

For model EMX3-0255C (3 required)

For model EMX3-0360C (3 required)

For models EMX3-0380C and EMX3-0430C (3 required)

For models EMX3-0620C and EMX3-0650C (3 required)

For model EMX3-0790C (3 required)

For model EMX3-0930C (3 required)

For model EMX3-1200C to EMX3-1600C (3 required)

170M1314

170M1316

170M1318

170M1319

170M1321

170M2621

170M2621

170M5011

170M6011

170M6008 2)

170M6013

170M5015

170M5017

170M6017

170M6018

170M2621

170M6010

170M6011

170M6015

170M6017

170M6019 2

)

Refer NHP

Semiconductor fuse holders (1 holder per fuse)

For 170M1314 to 170M2621

For 170M5011

For 170M5015 to 170M6017

For 170M6018 and 170M6019

Fieldbus communication modules

Modbus (RTU)

Modbus (TCP)

DeviceNet

ProfiBus

ProfiNet

Ethernet IP

USB module (EMX3 to PC via USB)

Input / Output cards

2 x digital inputs, 3 x relay outputs, 1 x analogue input

Additional protection card

RTD and ground fault card

Keypad remote mount kit

Keypad (Spare part)

Finger guards (for models 0145B-0220B) 3)

3 - 21

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Soft starters EMX3 series technical / ordering details

Dimensions (mm) and weights (kg)

A

EMX3-0023B to EMX3-0053B

EMX3-0076B

EMX3-0097B to EMX3-0105B

EMX3-0145B to EMX3-0220B

EMX3-0255B

EMX3-0350B to EMX3-0425B

EMX3-0500B to EMX3-0580B

EMX3-0700B to EMX3-1000B

EMX3-0255C

EMX3-0360C to EMX3-0430C

EMX3-0620C to EMX3-0930C

EMX3-1200C to EMX3-1600C

156

156

156

282

424

424

433

433

390

430

430

574

B

124

124

124

250

376

376

320

640

320

320

320

500

C

295

295

295

438

440

440

640

640

417

698

698

750

D

278

278

278

380

392

392

600

600

400

522

522

727

E

192

223

223

250

298

298

297

297

284

302

302

361

kg

3.2

3.5

4.8

16

26

30.2

49.5

60

25

50.5

53.5

140

Note: For EMX3-0145B to EMX3-1600C, dimensions A and C are the unit footprint. Busbars are not included as this dimension will vary with busbar configuration.

Frame

G1B

G1B

G1B

G2B

G3B

G3B

G4B

G4B

G3C

G4C

G4C

G5C

3 - 22

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Soft starters EMX3 series specifications

Supply

Supply voltage EMX3-XXXX-V4-XX-X

Supply voltage EMX3-XXXX-V7-XX-X

Electronics supply EMX3-XXXX-XX-C1-X

EMX3-XXXX-XX-C2-X

Supply frequency

Control inputs

Start (Terminals C23, C24)

Stop (Terminals C31, C32)

Reset (Terminals C41, C42)

Programmable input A (Terminals C53, C54)

Programmable input B (Terminals C63, C64)

Outputs

Run output

Programmable output A (Terminals 13, 14)

Programmable output B (Terminals 31, 32, 34)

Programmable output C (Terminals 41, 42, 44)

Analogue output (Terminals B10, B11)

Sundry

Enclosure rating EMX3-0023B ~ EMX3-0105B

Enclosure rating EMX3-0145B ~ EMX3-1000B

Enclosure rating EMX3-0255C ~ EMX3-1600C

Rated insulation voltage to earth

Rated impulse withstand voltage

Form designation

EMC emissions

Operating temperatures

Relative humidity

Standards / approvals

CE

UL/C-UL

CCC

C

Marine

RoHS

200 V AC ~ 440 V AC (± 10 %)

380 V AC ~ 690 V AC (± 10 %) (earthed star supply system only)

110 ~ 220 V AC and 220 ~ 440 V AC (+ 10 % / - 15 %) (standard)

24 V AC AC/24 V DC (± 20 %) (optional)

45 Hz (50 Hz supply) to 66 Hz (60 Hz supply)

N/O, Active 24 V DC, 8 mA approx.

N/C, Active 24 V DC, 8 mA approx.

N/O or N/C, Active 24 V DC, 8 mA approx.

N/O or N/C, Active 24 V DC, 8 mA approx.

N/O or N/C, Active 24 V DC, 8 mA approx.

N/O 10 A at 250 V AC resistive

5 A at 250 V AC, AC 15 pf 0.3

N/O 10 A at 250 V AC resistive

5 A at 250 V AC, AC 15 pf 0.3

C/O 10 A at 250 V AC resistive

5 A at 250 V AC, AC 15 pf 0.3

C/O 10 A at 250 V AC resistive

5 A at 250 V AC, AC 15 pf 0.3

0-20 mA or 4-20 mA

IP 20

IP 00

IP 00

600 V AC

4 kV

Bypassed or continuous, semiconductor motor starter Form 1

IEC 60947-4-2 Class B

40 ºC, max 60 ºC with derating

5 % to 95 %

IEC 60947-4-2

UL 508

GB 14048-6

IEC 60947-4-2

Lloyds Marine No 1 Specification

Compliant with EU Directive 2002/95/EC

EMX3 specifications

3 - 23

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Cat. No.

Rated power

Supply voltage

Load type

Ambient temperature

Enclosure protection

EMC Filter

Display

Removable keypad

Keypad potentiometer

Overload capacity

Starting torque

Control type

Analogue inputs

Analogue outputs

Logic inputs

Logic outputs

Communication

Dynamic brake module 8)

PID function

Encoder feedback

Page reference

SINUS N (NANO)

0.4-2.2 kW

200-230 V

Internal First

environment

5 programmable

1 multifunction relay 1 prog logic

3 - 21

SINUS M (MICRO)

0.4-22 kW

200-230 V / 380-480 V

Internal Second

environment 2)

8 programmable

1 prog relay 2 prog logic

Internal

3 - 22

SINUS PENTA

2.2-2010 kW

380-690 V

Light (120 %) Standard (140 %) Heavy (175 %) Strong (200 %)

50 °C 1)

IP 20 / IP 54

Internal Second environment 2)

4 line backlit 7) LCD display

120 % / 140 % / 175 % / 200 % for 60 sec 3)

Up to 200 % for 120 sec

IFD = V/f VTC - vector torque control (open or closed loop)

FOC = Field oriented control

3 x configurable inputs 4) +10 V DC or 0 (4) - 20 mA

3 x configurable outputs 4) +10 V DC or 0 (4) - 20 mA

3 fixed 4) 5 prog (multiples possible)

2 prog relay 2 prog logic

RS 485/Modbus 5), Profibus®, DeviceNet™, Interbus, ControlNet, Ethernet

Internal 1)

3 - 24

Notes: 1) Dependant on size. 6) Enclosed versions available to IP 54. 2) First environment (Class B) filter as option. 7) Remote mount keypad option.

3) Corresponding to selected rating. 8) Requires external resistor. 4) Expandable. 5) Standard protocol.

Variable speed drives Product Selection Guide

NHP offer a wide range of Variable Speed Drives (VSD) to cover the many applications and control methods available. The selection table below provides a summary of the ratings and features of each product in the NHP range. Identify the ratings and features required for your application and select the VSD that is right for you. For additional information see the relevant pages as indicated at the bottom of the table.

If further assistance is required in selecting a VSD to suit your specific application, please contact your nearest NHP sales office.

Cat. No.

Rated power

Supply voltage

Load type

Ambient temperature

Enclosure protection

EMC Filter

Display

Removable keypad

Keypad potentiometer

Overload capacity

Starting torque

Control type

Analogue inputs

Analogue outputs

Logic inputs

Logic outputs

Communication

Dynamic brake module 8)

PID function

Encoder feedback

Page reference

Variable / constant torque

50 °C

IP 20 6)

7 segment LED

150 % for 60 sec

150 %

IFD = V/f Sensorless Vector Control

2 x analogue inputs 0-10 V DC and 4-20 mA

0-10 V DC

RS 485/Modbus 5), Profibus®, Ethernet, Interbus, DeviceNet™, Canopen, ControlNet

SINUS PENTA

2.2-2010 kW

380-690 V

Light (120 %) Standard (140 %) Heavy (175 %) Strong (200 %)

50 °C 1)

IP 20 / IP 54

Internal Second environment 2)

4 line backlit 7) LCD display

120 % / 140 % / 175 % / 200 % for 60 sec 3)

Up to 200 % for 120 sec

IFD = V/f VTC - vector torque control (open or closed loop)

FOC = Field oriented control

3 x configurable inputs 4) +10 V DC or 0 (4) - 20 mA

3 x configurable outputs 4) +10 V DC or 0 (4) - 20 mA

3 fixed 4) 5 prog (multiples possible)

2 prog relay 2 prog logic

RS 485/Modbus 5), Profibus®, DeviceNet™, Interbus, ControlNet, Ethernet

Internal 1)

3 - 24

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘M5’

Variable speed drivesSINUS Nano

The SINUS Nano is an economical and compact micro drive by Santerno that incorporates both Sensorless Vector Control and V/f control. The digital keypad is included as standard and navigation through the menu structure is straightforward with its easy to use menu structure. The SINUS Nano is suitable for both constant and variable torque applications with automatic and manual torque boost for high inertia applications. A dwell function is included as standard which makes the drive suitable for hoisting applications. Furthermore, the SINUS Nano includes a motor auto-tuning function to ensure the drive is optimised for high performance motor operation. The SINUS Nano conforms to EMC requirements for C-Tick first environment.

--

Supplyvoltage (V)

SN 0001 2S XB K2

SN 0002 2S XB K2

SN 0003 2S XB K2

SN 0005 2S XB K2

0.4

0.75

1.5

2.2

2.5

5

8

12

Motorrating(kW)

Ratedoutputcurrent (A) Cat. No. Price $H

143

143

143

143

W

79

79

156

156

D

143

143

143

143

Dimensions (mm)

Ordering details SINUS Nano

Features at a glance:

Capacity 0.4 kW to 2.2 kW Single phase 200-230 V AC supply 2 control modes – V/f and sensorless vector control Front panel stop/start and potentiometer controls IP 20 enclosure Motor auto-tuning for increased performance PID functionality Integral EMC input filter complies with C-Tick first environment (domestic & industrial) Fixed height and depth throughout the range

Options:

Input/output chokes Communications card RS 485/Modbus Communications device for DeviceNet™/Profibus®/Ethernet/Interbus/Canopen/ControlNet

including programming cable and software

Standard Specifications:

Input voltage: Single phase 200-240 V ACControl system: Inverter frequency drive (V/f) and sensorless vector controlOverload current rating: 150 % overload capacity (for 1 minute)Protection functions: Over/undervoltage, overcurrent, inverter overheat, motor overheat, I/O phase

loss, external I/O input fault, speed command loss, hardware fault, CPU error, overload, external device fault

Frequency setting: External potentiometer, digital keypad, communication (Modbus), 0-10 V DC, 0-20 mA.

Protection: IP 20Environmental: -10 to +50 °C operational, -20 to +65 °C storage, 0 to 90 % RH non-condensing

WattLoss (w)

7

25

48

73

3 - 25

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘M5’

Variable speed drivesSINUS Micro

Features at a glance: Capacity 0.4 kW to 22 kW Single/three phase 200-230 V AC and three

phase 380-480 V AC supply V/f and sensorless vector control modes Built-in RS 485/Modbus IP 20 enclosure Motor auto-tuning for increased performance PID functionality Fire mode for HVAC applications Internal fan control

Integral EMC input filter complies with C-Tick second environment (industrial) optional first environment EMC filter available

Integrated braking unitOptions:

EMC filters for first environment (domestic) Input/output chokes Braking resistors Remote mounting keypad Full range of high-level communications

available

The SINUS Micro is a fully featured compact drive with the smallest sized footprint in its class. With Sensorless Vector Control and V/f control for both constant and variable torque applications, plus the addition of manual and automatic torque boost, this drive is suitable for all types of applications. Extremely easy to use, the SINUS Micro is compatible with the Remote Drive software and complies with EMC requirements.

Standard Specifications:

Input voltage: Single/three phase 200-240 V AC and three phase 380-480 V AC Control system: Inverter frequency drive (V/f) and sensorless vector controlOverload current rating: 150 % overload capacity (for 1 minute)Dynamic braking: 20 % without brake resistor. Average 150 % with external brake resistorProtection functions: Over/undervoltage, overcurrent, inverter overheat, motor overheat,

external I/O input fault, I/O phase loss, speed command loss, ground fault current detection, output phase open, fan trip, hardware fault, overload, communication error

Frequency setting: Digital keypad, communication - Modbus/Fieldbus (option) 0-10 V DC, 0-20 mA. Protection: IP 20Environmental: -10 to +50 °C operational, -20 to +65 °C storage, 0 to 90 % RH non-condensing

200-240, 1/3 phase

200-240, 1/3 phase

200-240, 1/3 phase

200-240, 1/3 phase

200-240, 1/3 phase

200-240, 1/3 phase

200-240, 1/3 phase

200-240, 1/3 phase

200-240, 1/3 phase

200-240, 1/3 phase

200-240, 1/3 phase

380-480, 3 phase

380-480, 3 phase

380-480, 3 phase

380-480, 3 phase

380-480, 3 phase

380-480, 3 phase

380-480, 3 phase

380-480, 3 phase

380-480, 3 phase

380-480, 3 phase

380-480, 3 phase

Supplyvoltage (V)

SM 0001 2ST BA2K2

SM 0002 2ST BA2K2

SM 0003 2ST BA2K2

SM 0005 2ST BA2K2

SM 0007 2ST BA2K2

SM 0011 2ST BA2K2

SM 0014 2ST BA2K2

SM 0017 2ST BA2K2

SM 0020 2ST BA2K2

SM 0025 2ST BA2K2

SM 0030 2ST BA2K2

SM 0001 4T BA2K2

SM 0002 4T BA2K2

SM 0003 4T BA2K2

SM 0005 4T BA2K2

SM 0007 4T BA2K2

SM 0011 4T BA2K2

SM 0014 4T BA2K2

SM 0017 4T BA2K2

SM 0020 4T BA2K2

SM 0025 4T BA2K2

SM 0030 4T BA2K2

0.4

0.75

1.5

2.2

4.0

5.5

7.5

11

15

18.5

22

0.4

0.75

1.5

2.2

4.0

5.5

7.5

11

15

18.5

22

2.5

5

8

12

17

24

32

46

60

74

88

1.25

2.5

4

6

9

12

16

24

30

39

45

H

128

128

128

128

128

220

220

320

320

410

410

128

128

128

128

128

220

220

320

320

410

410

W

70

70

100

140

140

180

180

235

235

260

260

70

70

100

140

140

180

180

235

235

260

260

D

130

130

130

155

155

170

170

190

190

210

210

130

130

130

155

155

170

170

190

190

210

210

Motorrating(kW)

Ratedoutputcurrent (A) Cat. No. Price $

Dimensions (mm)

Ordering details SINUS Micro

WattLoss (w)

13

28

18

56

106

73

70

290

683

759

799

9

22

32

47

94

84

113

293

608

759

1019

3 - 26

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘M5’

First environment EMC filterIf compliance to the first environment is required (domestic installations) then an additional foot print EMC filter is required when using the SINUS Micro. The SINUS Nano incorporates a first environment (domestic installation) and second environment (industrial installation) EMC filter as standard.

Braking resistorsThe SINUS Micro incorporates an internal brake module which allows the connection of an external IP 55 brake resistor which may be required in applications where fast deceleration is required or where there is a high intertia load and avoids nuisance tripping caused by regeneration.

Inverter ModelSM-XXXX-XXX-BA2K2

Current Rating (A)

Dimensions (mm) L W H

Cat. No. Price $

0001-0002 2ST

0003 2ST

0005-0007 2ST

0011 2ST

0014 2ST

0001-0002 4T

0003 4T

0005-0007 4T

0011-0014 4T

5

12

20

30

50

5

6

11

30

175

177

177

266

270

175

177

177

266

SME00022ST

SME00032ST

SME00072ST

SME00112ST

SME00142ST

SME00024T

SME00034T

SME00074T

SME00144T

Inverter ModelSM-XXXX-XXX- BA2K2

Resistor Specification Watts Resistance (W) ( )

Dimensions (mm)L W H

Brake resistor Cat. No. Price $

0001 2ST

0002 2ST

0003 2ST

0005 2ST

0007 2ST

0011 2ST

0014 2ST

0001 4T

0002 4T

0003 4T

0005 4T

0007 4T

0011 4T

0014 4T

350

350

350

350

350

1100

1100

350

350

350

350

350

550

1100

200

200

200

200

200

320

320

200

200

200

200

200

195

320

RE2644200

RE2644100

RE2643560

RE2643560

RE2643560

RE3083500

RE3083500

RE2644400

RE2644400

RE2644200

RE2644200

RE2644200

RE3063750

RE3083500

Description Cat. No. Price $

MODBUS/RS485 Communications card

Door mount kit for remote keypad mounting

(includes IP 66 keypad, gasket, 3 m cable)

PC Software kit for use with Remote Drive(includes cable, USB/RS485 converter – Remote Drive software available from www.nhp.com.au/santerno)

Profibus® DP serial gateway 1)

DeviceNet™ serial gateway 1)

Ethernet serial gateway 1)

Interbus serial gateway 1)

CANOpen serial gateway 1)

ControlNet serial gateway 1)

To suit range

SN

SM

SNSM

SN 2)/SM

SN 2)/SM

SN 2)/SM

SN 2)/SM

SN 2)/SM

SN 2)/SM

WW1420000

SMDMK

SPUSB

ZZ4600030

SNMDEVNT

SNMETHNT

SNMINTBS

SNMCANOP

SNMCTLNT

Additional options

Notes: 1) Contact NHP for further information. 2) WW1420000 required for fieldbus communication when using SINUS Nano.

Variable speed drivesSINUS Nano and Micro options

77

108

147

185

190

77

107

147

186

40

40

45

60

60

40

40

45

60

35

35

35

35

35

95

95

35

35

35

35

35

68

95

30

30

30

30

30

30

30

30

30

30

30

30

13

30

200

100

56

56

56

15

15

400

400

200

200

200

75

50

To suit range

SM

SM

SM

SM

SM

SM

SM

SM

SM

To suit range

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

3 - 27

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Refer catalogue ESD-C

The SINUS PENTA is the latest fully featured drive to be released by Santerno of Italy. This model boasts an extensive range of features to allow easy adaptation to a wide variety of applications while being easy to use, with a 4 line alphanumeric display with all text in plain English. All drives feature a full metal enclosure to provide robustness to suit the demands of industrial environments. In addition the metal enclosure minimises radiated EMC. The full range of drives up to 1 MW, 415 V and 2 MW, 690 V contain internal EMC filters complying with C-Tick Second Environment (Class A). With the addition of a ferrite core, the standard drive is also suitable for use in the First Environment (Class B) up to frame size S50. Further flexibility is also achieved with the inclusion of an IP 54 version for sizes up to S30 (132 kW). The IP 54 drive is a stand-alone wall mounted device which can be expanded to include a choke and additional pushbuttons and switches.

Features at a glance: Wide power and voltage range. 2.2-2010 kW, 380-690 V IP 20 and IP 54 standard solutions Selectable overload from 120 % to 200 % Built-in EMC filters to comply with for the entire range 3 year warranty Five built-in control types (see below) Regenerative/Active front end option 4 line alphanumeric display Extensive I/O configuration Fire mode solution to suit HVAC application Zero speed Fluxing (in VTC mode) Wide range of options available Integral brake chopper up to 132 kW ModBus RTU communications standard Optional fieldbus for all major protocols Cabinet solution available PC communication software with internet connectivity Extensive fault history record Safety stop function to IEC 61800-5-2

Options (see pages 3 - 35 and 3 - 44) EMC filter conforming to C-Tick

first environment Dynamic braking resistors AC line choke Output choke Semiconductor fuses

Keypad mounting kit I/O expansion cards Encoder cards PC software and cables Communication and fieldbus

cards Harmonic filters

Variable speed drives for AC motorsIntroduction to SINUS PENTA

PENTA – Five integrated control functions

The SINUS PENTA incorporates five built-in control functions to accommodate a wide range of applications. This allows the one product to be adapted to many types of control philosophies and therefore provide the best performance for your application. These include the following functions.

IFD = Inverter Frequency DriveThis function offers an adjustable V/f pattern for general purpose applications.

VTC Open Loop = Vector Torque Control Open LoopThrough Sensorless Vector Direct Torque Control, the VTC function allows for improved torque performance without the need for feedback.

VTC Closed Loop = Vector Torque Control Closed LoopThe VTC function allows for fast dynamic response through encoder feedback for high torque or demanding applications.

FOC = Field Oriented ControlFOC is the ultimate in vector speed control providing high accuracy through encoder feedback for high torque precision and a wide speed range.

SYN = SynchronousThis control function provides a vector function for the control of brushless synchronous permanent magnet motors. This provides high torque accuracy combined with energy efficiency.

3 - 28

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

User friendly interfaceThe 4 line alphanumeric keypad provides clear plain English text messaging for monitoring, parameter configuration and fault annunciation making the SINUS PENTA extremely user friendly. To simplify local operation, the keypad incorporates dedicated keys for Start, Stop, direction of rotation, local/remote selection, jog and reset. These keys are in addition to the standard programming keys. Status monitoring is made easy with the use of 11 LEDs to indicate conditions such as run, alarm, direction of rotation and local control active. The keypad has built-in intelligence to enable parameters to be uploaded and downloaded directly from the keypad.

To simplify commissioning and parameters set-up, the drive has three selectable access levels. Basic level is designed for simple applications, advanced is for applications requiring additional flexibility and engineering for applications requiring full configuration. The accessible parameters are minimised to suit the control function used and the access level selected. This allows the drive to have as few as 30 parameters for basic application or as many as 500 parameters for the most sophisticated applications.

Flexible connectionThe SINUS PENTA is designed for flexibility. This flexibility is incorporated into the extensive range of I/Os available. The SINUS PENTA incorporates as standard three programmable analogue inputs and outputs. Also included are eight digital inputs, two digital outputs and two relay outputs. Inputs are programmable with the ability for dual assignment for activation of two functions simultaneously. Outputs incorporate both timing and logic for added flexibility. In addition, option boards are available to extend the number of I/Os. Having flexible inputs and outputs allows the SINUS PENTA to easily adapt to a wide range of control solutions.

ConnectivityConnectivity to a PC is possible using the "Remote Drive" software, which offers tools for the control of the drive, trending functions, setting and storage of parameters and online monitoring. Remote Drive allows the added benefit of providing a remote communication service by using a simple internet connection. The remote drive software and chat line allows fast communication between the inverter’s user and our engineers.Extensive connectivity is achieved by the use of a wide range of communication interfaces available. The drive incorporates Modbus-RTU and RS 485 as standard and with the addition of an option board, which can be mounted within the drive, all the other major fieldbus protocols can be accommodated such as Profibus DP, DeviceNet, CanBus, Interbus, Ethernet and many more currently in development.

Robust constructionThe SINUS PENTA range are designed for robustness to meet the demands of industrial applications. The complete series includes a full metal enclosure for durability. The robustness extends to the full system. With a high level of quality and reliability as well as strict adherence to international standards such as ISO 9001, Santerno is able to offer a three year warranty. This dependability provides the confidence that the drive can meet the challenge of demanding applications.

IP 54 solutionFor many applications it is advantageous to install the drive directly on a machine, close to the motor, or on a wall. For this reason a higher enclosure protection is required. The SINUS PENTA is available in sizes up to 132 kW providing an economical and convenient solution. This solution is particularly suited to HVAC applications, irrigation, the food industry or applications requiring dispersed motor control. The robust IP 54 frame provides a removable gland plate, space to mount additional components if required and the ability to add additional controls to the front of the drive. For applications requiring the addition of a choke, a dedicated IP 54 option can be added to the drive construction.

Enclosed systemsBy calling on the extensive range of options and products available an enclosed drive package can be tailored to suit the specific requirements of an application. The system can be customised to include options such as contactors, chokes, semiconductor fuses, dynamic braking solutions, communications options and many more. Please contact your NHP representative to discuss your specific requirements.

Variable speed drives for AC motorsIntroduction to SINUS PENTA

3 - 29

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

First Environment Environment that includes domestic premises, or establishments directly connected without intermediate transformers to a low-voltage power supply network which supplies buildings used for domestic purposes.

Second Environment Environment that includes all establishments than those directly connected to a low-voltage power supply network which supplies buildings used for domestic purposes.

PDS of Category C1

PDS of rated voltage less than 1000 V, intended for use in the first environment.

PDS of Category C2 PDS of rated voltage less than 1000 V, which is neither a plug-in service nor a movable device and, when used in the first environment, is intended to be installed and commissioned only by a professional.

PDS of Category C3 PDS of rated voltage less than 1000 V, intended for use in the second environment.

PDS of Category C4 PDS of rated voltage equal or above 1000 V, or rated current equal or above 400 A, or intended for use in complex systems in the second environment.

Below are the AS 61800-3 2005 definitions on emission limits: (PDS = power drive system)

EMC Requirements

EMI (Electromagnetic Interference) is normally caused by commutations in many devices. The high frequency interference can affect the operation of other devices and can create noises in measurement and communication systems. All these combined effects can create unexpected breakdowns. Two areas can be affected by the above: immunity and emissions.

AS 61800-3 is the product-specific drives standard that defines both immunity and emission levels required for those devices designed to operate in different environments. The SINUS PENTA range is designed to operate under different conditions, therefore they are all provided with a strong immunity against RFI that allows them to be reliable in all environments. Furthermore the complete range of drives in the SINUS PENTA series are C-Tick approved with integral EMC filters and conform to category C3 for the Second Environment. With the addition of a ferrite core, the drives can comply to category C1 for the First Environment. To simplify installation of analogue signals screen terminations are also included as standard.

Variable speed drives for AC motors Introduction to SINUS PENTA

Engineered solutions

For applications requiring more specialised solutions, Engineered systems can be developed. Solutions that are available include 12 or 18 pulse input configuration for reduced harmonic distortion and fully regenerative solutions to allow regenerated energy to be fed back to the supply. Special application software is also available to fulfill the requirements of specific applications such as multi-pump control, servo-diameters, axis control and positioning applications. These applications can be loaded into a standard SINUS PENTA drive. For further details on these specialised areas please contact NHP.

3 - 30

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Step 8Step 7

Step 3

Step 5 Step 6

Variable speed drives for AC motorsDrive selection

Selection of a SINUS PENTA variable drive system is

extremely simple by following the steps shown below:

Step 1 Step 2Using the application overload table on section 3 - 28 identify your application which matches closest with those shown in the list. Once an application has been selected, identify the correct overload rating based on the location of the mark. If unsure, contact NHP.If two overload ratings are selected, choose the overload rating that best suits your application.

For 380-500 V AC drives, based on your drive model selection from step 2 and using the table on page 3 - 30, identify the correct part number and price in either IP 20/00 or IP 54 (to 132 kW) models.OR

For 660-690 V AC drives, use the table on page 3 - 40 to identify the correct part number and price in IP 20/00 models.

From the selection table on page 3 - 29, identify the column that contains the selected overload rating from step 1 and choose the 380-500 V AC drive model that matches or exceeds your motor full load current.OR

From the selection table on page 3 - 40 use the same process to select your 660-690 V AC drive model.

For 380-500 V AC drives, contact NHP for first environment EMC filters for use in domestic installations, input semi-conductor fuses + accessories to protect the drive in the event of short circuit upstream of the drive on page 3 - 33. OR

For 575-690 V AC drives and optional first environment filters and fuses + accessories, contact NHP.

For 380-500 V AC and 575-690 V AC drives, select optional braking resistors and braking units (>S40) using the selection table on page 3 - 34 and then view technical details and pricing on table 3 - 35.

For additional information:• 380-500 V AC selection

table including isolators, contactors, etc. on pages 3 - 36 to 3 - 39

• Multipump application page 3 - 42

• Regenerative application page 3 - 43

For all SINUS PENTA drives, refer to page 3 - 44 for details on options such as fieldbus communications, remote door mount kits, harmonic filters, etc.

Step 4 For 380-500 V AC drives, select optional input/output chokes on page 3 - 32 based on the drive size – e.g. SP0014, and available in IP 20 and IP 54 versions. For long cable runs and drives >S50, input and output chokes are recommended.OR

For 575-690 V AC drives, select input/output chokes on page 3 - 41.

3 - 31

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Application Light Standard Heavy Strong

Agitator

Atomiser

Axis control

Bottle washer

Calenders

Centrifuge

Chipper

Compressor – piston (loaded)

Compressor – piston (unloaded)

Compressor – screw (loaded)

Compressor – screw (unloaded)

Conveyor – belt

Conveyor – roller

Conveyor – screw

Crusher – cone

Crusher – jaw

Crusher – rotary

Crusher – vertical impact

Debarker

Drawplates

Drill

Dryer

Dust collector

Edger

Elevator

Extruder

Fan – axial (damped)

Fan – axial (undamped)

Fan – centrifugal (damped)

Fan – centrifugal (undamped)

Fan – high pressure

Forming machine

Grinder

Application Light Standard Heavy Strong

Hoist/crane

Hydraulic power pack

Injection moulding – screw

Injection moulding – hydraulic power pack

Loom

Mill – ball

Mill - hammer

Mill - roller

Mixer

Paint stirrer Palletiser

Planer

Press

Pulper

Pump – bore

Pump – centrifugal

Pump – positive displacement/ submersible

Pump – slurry

Rotary table

Sander

Saw – band

Saw – Circular

Shears

Separator

Shredder

Slicer

Spinner

Tumbler

Vibrating screen

Washer – industrial

Winding/Unwinding

Variable speed drives

Typical application overload requirements

Light up to 120 % overload

Standard up to 140 % overload

Heavy up to 175 % overload

Strong up to 200 % overload

3 - 32

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

IpeakCat. No.Size kW A kW A kW A kW A A A

Inom = Inverter nominal continuous current ratingImax = Inverter maximum current for 120 sec every 20 min up to S30 and 60 sec every 10 min all other sizes1 peak = Inverter maximum current for 30 sec

Light Standard Heavy Strong Inom Imax

S15 1)

S05 1)

Variable speed drives SINUS PENTA Range and selection

Power Supply 380-415 V AC

S12 1)

S20 1)

S30 1)

S60

S65 2)

4.5 9 4 8.4 3 6.4 2.2 4.9 10.5 11.5 14 5.5 11.2 4.5 9 4 8.4 3 6.4 12.5 13.5 167.5 14.5 5.5 11.2 4.5 9 4 8.4 16.5 17.5 197.5 14.8 7.5 14.8 5.5 11.2 4.5 9 16.5 21 257.5 14.8 7.5 14.8 7.5 14.8 5.5 11.2 16.5 25 30

11 21 9 18 9 18 7.5 15 27 30 3615 29 11 21 9 18 7.5 15 30 32 3715 29 15 29 11 21 9.2 18 30 36 4322 41 18.5 35 15 29 11 21 41 48 5822 41 22 41 18.5 35 15 29 41 56 6730 55 25 46 22 41 18.5 35 57 63 76

30 55 30 55 25 46 22 41 60 72 8637 67 30 55 25 46 22 41 72 80 8845 80 37 67 30 55 25 46 80 96 115

50 87 45 80 37 67 30 55 88 112 13455 98 55 98 45 80 32 59 103 118 14265 114 65 114 50 87 37 67 120 144 17375 133 75 133 55 98 45 80 135 155 186

100 180 90 159 75 133 55 98 180 200 240110 191 100 180 80 144 65 114 195 215 258120 212 110 191 90 159 75 133 215 270 324132 228 132 228 110 191 90 159 240 290 324

160 273 150 264 132 228 110 191 300 340 408200 341 160 273 160 273 132 228 345 420 504220 375 220 375 185 321 150 260 375 460 552250 425 250 425 220 375 185 321 425 450 672280 480 280 480 250 421 200 341 480 600 720315 528 315 528 280 480 220 375 550 680 792 400 680 400 680 355 589 280 480 680 850 1020400 680 400 680 315 528 280 480 720 880 1056450 765 450 765 355 589 315 528 800 960 1152

500 841 500 841 400 680 355 589 900 1100 1320560 939 560 939 500 841 400 680 1000 1300 1560710 1200 630 1080 560 939 450 765 1200 1440 1728

900 1480 800 1334 710 1200 560 939 1480 1780 21361000 1646 900 1480 800 1334 710 1200 1700 2040 24481170 1950 1100 1874 900 1480 800 1334 1950 2340 3024

Light up to 120 % overloadStandard up to 140 % overload

Heavy up to 175 % overloadStrong up to 200 % overload

Note: 1) Available in IP 54 version 2) Require input and output chokes 3) NHP standard model

SP 0005 4TBA2K2SP 0007 4TBA2K2SP 0009 4TBA2K2SP 0011 4TBA2K2SP 0014 4TBA2K2SP 0016 4TBA2K2SP 0017 4TBA2K2SP 0020 4TBA2K2SP 0025 4TBA2K2SP 0030 4TBA2K2SP 0034 4TBA2K2SP 0036 4TBA2K2SP 0040 4TBA2K2SP 0049 4TBA2K2SP 0060 4TBA2K2SP 0067 4TBA2K2SP 0074 4TBA2K2SP 0086 4TBA2K2SP 0113 4TBA2K2SP 0129 4TBA2K2SP 0150 4TBA2K2SP 0162 4TBA2K2SP 0180 4TXA2KOSP 0202 4TXA2K0SP 0217 4TXA2K0SP 0260 4TXA2K0SP 0313 4TXA2K0SP 0367 4TXA2K0SP 0402 4TXA2K0SP 0457 4TXA2K0SP 0524 4TXA2K0SP 0598 4TXA2K0SP 0748 4TXA2K0SP 0831 4TXA2K0SP 0964 4TXA2K0SP 1130 4TXA2K0SP 1296 4TXA2K0

Catalogue Number Construction

Range

S = SINUS 3)SB = SINUS BOXSC = SINUS CABINET

Voltage rating

2 = 200-240 V4 = 380-500 V 3)5 = 500-575 V6 = 575-690 V

EMC Filter

I = NoneA1 = First env. category C2A2 = Second env. 3) category C3 B = First env. category C1

IP Rating

0 = IP 002 = IP 203 = IP 24-314 = IP 425 = IP 54C = Air Cond.

Drive size Brake chopper

X = NoneB = Integral

Keypad

X = NoneK = Integral 3)Power supply

T = Three phase 3)S = Single phaseC = DC FedD = 12 Pulse input

Model

PENTA 3)

S P 0005 4 T B A2 K 2

S41

S75 2)

S51

3 - 33

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘M5’

Variable speed drivesSINUS PENTA - 380-415 V IP 20 / IP 00

S20

S05

S75

S15

S05

Ordering details

S12

S20

S30

S60

S65

1980

225

170

215

279

302

890

980

1400

466

340

401

610

748

1310

1400

560

331

175

225

332

421

530

560

IP 00

IP 20

IP 20

IP 20

IP 20

IP 20

IP 00

IP 00

Size WDimensions (mm)

H D IP Rating WeightLosses at Inom (W) Cat No. Price $

77777

10.510.510.511.511.512.512.522.522.53636363651515151117117121121141141141260260440440440550550550

2152403153153154304904905205206807108209501050125013501500215023002450270025503200345039504400490063007400840097501075012900154001700018600

SP 0005 4TBA2K2

SP 0007 4TBA2K2

SP 0009 4TBA2K2

SP 0011 4TBA2K2

SP 0014 4TBA2K2

SP 0016 4TBA2K2

SP 0017 4TBA2K2

SP 0020 4TBA2K2

SP 0025 4TBA2K2

SP 0030 4TBA2K2

SP 0034 4TBA2K2

SP 0036 4TBA2K2

SP 0040 4TBA2K2

SP 0049 4TBA2K2

SP 0060 4TBA2K2

SP 0067 4TBA2K2

SP 0074 4TBA2K2

SP 0086 4TBA2K2

SP 0113 4TBA2K2

SP 0129 4TBA2K2

SP 0150 4TBA2K2

SP 0162 4TBA2K2

SP 0180 4TXA2K0

SP 0202 4TXA2K0

SP 0217 4TXA2K0

SP 0260 4TXA2K0

SP 0313 4TXA2K0

SP 0367 4TXA2K0

SP 0402 4TXA2K0

SP 0457 4TXA2K0

SP 0524 4TXA2K0

SP 0598 4TXA2K0

SP 0748 4TXA2K0

SP 0831 4TXA2K0

SP 0964 4TXA2K0

SP 1130 4TXA2K0

SP 1296 4TXA2K0

S41

S51

500 882 409 IP 00

578 882 409 IP 00

Frame S41 & S51: no more pre-charge bypass contactor and resistor offers you improved reliability compared to traditional pre-charge systems. Check availability with NHP.

NEW

3 - 34

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

S30

S05

S15

S05

Ordering details

S12

S20

S30

288

214

250

339

359

715

577

622

842

1008

366

227

268

366

460

IP 54

IP 54

IP 54

IP 54

IP 54

SizeWDimensions (mm)

H D IP Rating Weight Losses at Inom (W) Cat No. Price $

15.715.715.715.715.722.322.322.323.323.324.324.34040

54.254.2575776767676

21524031531531535038042052552568071082095010501250135015002150230024502700

SP 0005 4TBA2K5

SP 0007 4TBA2K5

SP 0009 4TBA2K5

SP 0011 4TBA2K5

SP 0014 4TBA2K5

SP 0016 4TBA2K5

SP 0017 4TBA2K5

SP 0020 4TBA2K5

SP 0025 4TBA2K5

SP 0030 4TBA2K5

SP 0034 4TBA2K5

SP 0036 4TBA2K5

SP 0040 4TBA2K5

SP 0049 4TBA2K5

SP 0060 4TBA2K5

SP 0067 4TBA2K5

SP 0074 4TBA2K5

SP 0086 4TBA2K5

SP 0113 4TBA2K5

SP 0129 4TBA2K5

SP 0150 4TBA2K5

SP 0162 4TBA2K5

Variable speed drives

Price Schedule ‘M5’

3 - 35

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘M5’

Input and output choke - 380-415 V

Input choke:

When installing a VSD of size S40 (230 kW) or less, a choke is recommended in the following situations:

to reduce the impact of mains instability to reduce harmonics to protect against the effects of switching devices on the mains to improve wave shape

For sizes S50 and above, it is recommended to always use a line reactor (choke) unless a dedicated transformer is used. DC chokes are available on request.

Output choke:

When installing a VSD of size S40 (230 kW) or less, an output choke is recommended in the following situations:

Long motor output cables Reduce reflected waves Reduce dV/dt to the motor When multiple motors are connected to one VSD

For sizes S50 and above, it is recommended to always use an output reactor (choke).

IP 54 ChokeA separate choke is available in IP 54, specifically designed to integrate into the IP 54 VSD solution. This choke fits under the drive to allow for connections. The choke can be used on either the input or output side of the drive.

Ordering details 380-415 V Chokes IP 20/ IP 00

Ordering details 380-415 V Chokes IP 54

Variable speed drivesInput and output choke

m

S05 - S12

S15 - S30

S40

S50 - S75

30 60 90 120 150 >150

2-4-6 pole motorsMotor wiring with unscreened cables

Up to S12

Up to S30

Up to S40

from S40

20 40 80 > 80 m

2-4-6 pole motorsMotor wiring with screened cables

Legend:

Output chokes are required.

Output chokes are optional

00050007-00140016-00200025-00300034-00380040-00600067-00860113-01620179-02020216-02600312-03990402-05980748-08310964-11300964-113012961296

Input & OutputInput & OutputInput & OutputInput & OutputInput & OutputInput & OutputInput & OutputInput & OutputInput & OutputInput & OutputInput & OutputInput & OutputInput & OutputInputOutputInputOutput

11173243689214225236241066294512602 x 9456 x 9502 x 12606 x 1250

21.270.70.70.30.240.160.090.0610.0540.0330.0230.0180.0230.0240.0180.018

120120150150180180240240300300300300300300385300385

125135175175160160210210260290290320320320430320430

7590105125150155170220220230230260260260260260260

IP 20IP 20IP 20IP 20IP 20IP 00IP 00IP 00IP 00IP 00IP 00IP 00IP 00IP 00IP 00IP 00IP 00

2.935691024.524.537535367852 x 672 x 1002 x 822 x 100

2948709615018327234240750050075210702 x 7526 x 9402 x 10706 x 940

IMO126004

IM0126044

IM0126084

IM0126124

IM0126144

IM0126164

IM0126204

IM0126244

IM0126284

IM0126324

IM0126364

IM0126404

IM0126444

2 X IM0126404

6 X IMO141782

2 X IM0126444

6 X IMO141782

To suit size

SP...4T...

Suitable for

input/output

Rating

(A) (mH)

Dimensions (mm)

L H D

IP

Rating

Weight

(kg)

Losses at

Inom (W) Cat. No. Price $

00050007-00140016-00200025-00300034-00360038-00600067-00860113-0162

Input & OutputInput & OutputInput & OutputInput & OutputInput & OutputInput & OutputInput & OutputInput & Output

111732436892142252

2.01.270.70.70.30.240.160.09

214214214214280280310310

225225225225270270360360

214214214214244244318318

IP 54IP 54IP 54IP 54IP 54IP 54IP 54IP 54

6.57.09.51014152633

29487096150183342342

ZZ0112010

ZZ0112020

ZZ0112030

ZZ0112040

ZZ0112045

ZZ0112050

ZZ0112060

ZZ0112070

To suit size

SP...4T...

Suitable for

input/output

Rating

(A) (mH)

Dimensions (mm)

L H D

IP

Rating

Weight

(kg)

Losses at

Inom (W) Cat. No. Price $

3 - 36

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘M5’

Description

To suit size

SP ---4T BA2K2 Cat. No. Price $

Semiconductor fuses are recommended to protect the rectifier in the event of a short circuit. Standard fuses and circuit breakers alone are generally not adequate due to slower switch-off times.

When used in conjunction with the internal A2 (second environment) EMC filter, this ferrite allows the VSD to be suitable for use in the First Environment (class B) for residential and commercial use. The ferrite is installed between the output of the VSD and the motor by passing the three phases through the centre of the ferrite.

Details upon request.

Dimensions (mm)

For three fuses incl. base

Accessories

Semiconductor fuses

EMC Filter for first environment

Variable speed drivesSemiconductor fuses and EMC filters

Notes: 1) One fuse required per phase. 2) Two fuses required per phase.

0005-0007

0009-0011

0014-0020

0025-0030

0034-0049

0060-0067

0074

0086

0113-0129

0150

0180

0162-0200

0202

0216-0217

0260-0313

0250-0367

0312-03990402

0457

0524

0598-0748

0831

0964

1130

1269

16 A

25 A

40 A

63 A

100 A

125 A

160 A

200 A

250 A

315 A

350 A

400 A

500 A

550 A

630 A

700 A

800 A

900 A

1000 A

1250 A

1400 A

2 x 800 A

2 x 1000 A

2 x 1250 A

2 x 1400 A

146

146

146

146

146

146

146

146

146

146

146

146205

205

205

205

205

205

205

205

205

410

410

410

410

120

120

120

120

120

120

120

120

120

120

120

120120

258

258

258

258

258

258

258

258

258

258

258

258

68

68

68

68

68

68

68

68

68

68

68

6868

104

104

104

104

104

104

104

115

115

104

104

115

20 412 04 16

20 412 04 25

20 412 20 40

20 412 20 63

20 412 20 100

20 412 20 125

20 412 20 160

20 412 20 200

20 412 20 250

20 412 20 315

20 412 20 350

20 412 20 400

20 622 32 500

20 622 32 550

20 622 32 630

20 622 32 700

20 622 32 800

20 622 32 900

20 622 32 1000

20 622 32 1250

20 632 32 1400

20 632 32 800 2)

20 632 32 1000 2)

20 632 32 1250 2)

20 632 32 1400 2)

L H D Cat. No 1) Price $RatingTo suit size SP---4T...

21 189 01

21 313 02

28 002 02

28 001 04

0005-0200

0202-+

0005-0200

0202-+

Fuse base (one per fuse, three required per drive)

Fuse base (one per fuse, three or six required per drive)

Auxiliary switch

Auxiliary switch

3 - 37

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Variable speed drives Brake resistor selection by duty cycle

SP 0005 4TBA2K2SP 0007 4TBA2K2SP 0009 4TBA2K2SP 0011 4TBA2K2SP 0014 4TBA2K2SP 0016 4TBA2K2SP 0017 4TBA2K2SP 0020 4TBA2K2SP 0025 4TBA2K2SP 0030 4TBA2K2SP 0034 4TBA2K2SP 0036 4TBA2K2SP 0040 4TBA2K2SP 0049 4TBA2K2SP 0060 4TBA2K2SP 0067 4TBA2K2SP 0074 4TBA2K2SP 0086 4TBA2K2SP 0113 4TBA2K2SP 0129 4TBA2K2SP 0150 4TBA2K2SP 0162 4TBA2K2SP 0179 4TXA2K2SP 0200 4TXA2K2SP 0216 4TXA2K2SP 0250 4TXA2K2SP 0180 4TXA2K2SP 0202 4TXA2K2SP 0217 4TXA2K2SP 0260 4TXA2K2SP 0312 4TXA2K0SP 0366 4TXA2K0SP 0399 4TXA2K0SP 0313 4TXA2K2SP 0367 4TXA2K2SP 0402 4TXA2K2SP 0457 4TXA2K0SP 0524 4TXA2K0

Built-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-inBuilt-in

2 x BU200 2 x BU200 3 x BU200 3 x BU200BU700 2-4TBU700 2-4TBU700 2-4TBU700 2-4T4 x BU2004 x BU2004 x BU200BU700 2-4TBU700 2-4TBU700 2-4T5 x BU2005 x BU200

50 - 1100 W 50 - 1100 W 50 - 1100 W 50 - 1500 W 50 - 1500 W 50 - 2200 W50 - 2200 W50 - 4000 W 25 - 4000 W 25 - 4000 W20 - 4000 W 20 - 4000 W 15 - 8000 W 10 - 12000 W10 - 12000 W 10 - 12000 W10 - 16000 W10 - 16000 W2 x 3.3 - 8000 W 1)2 x 3.3 - 8000 W 1)2 x 10 - 12000 W 2)2 x 10 - 12000 W 2)2 x 6.6 - 12000 W 3) 2 x 6.6 - 12000 W 3)3 x 6.6 - 12000 W 3)3 x 6.6 - 12000 W 3)1 x 3.6 - 32000 W1 x 3.0 - 48000 W1 x 2.8 - 48000 W1 x 2.4 - 48000 W4 x 6.6 - 12000 W 3) 4 x 6.6 - 12000 W 3)4 x 6.6 - 12000 W 3) 1 x 1.8 - 64000 W1 x 1.8 - 64000 W2 x 2.8 - 48000 W5 x 10 - 12000 W 3)5 x 10 - 12000 W 3)

RE3083500

RE3083500

RE3083500

RE3093500

RE3093500

RE3113500

RE3113500

RE3483500

RE3483250

RE3483250

RE3483200

RE3483200

RE3783150

RE4023100

RE4023100

RE4023100

RE4163100

RE4163100

RE3762330

RE3762330

RE4023100

RE4023100

RE4022660

RE4022660

RE4022660

RE4022660

RE4362360

RE4462300

RE4462280

RE4462240

RE4022660

RE4022660

RE4022660

RE4562180

RE4562180

RE4462280

RE4023100

RE4023100

50 - 4000 W50 - 4000 W50 - 4000 W50 - 4000 W50 - 4000 W50 - 8000 W50 - 8000 W50 - 8000 W20 - 12000 W20 - 12000 W20 - 16000 W20 - 16000 W15 - 24000 W15 - 24000 W10 - 24000 W10 - 24000 W2x15 - 24000 W2x15 - 24000 W6 - 64000 W6 - 64000 W5 - 64000 W5 - 64000 W3 x 10 - 24000 W 3)3 x 10 - 24000 W 3)3 x 10 - 24000 W 3)4 x 10 - 24000 W 3)1 x 6.6 - 48000 W1 x 6.0 - 64000 W1 x 5.0 - 64000 W1 x 5.0 - 64000 W4 x 10 - 24000 W 3)6 x 10 - 24000 W 3)6 x 10 - 24000 W 3)1 x 1.6 - 48000 W1 x 1.6 - 48000 W1 x 1.4 - 64000 W8 x 10 - 24000 W 3)10 x 10 - 24000 W 3)

RE3503500

RE3503500

RE3503500

RE3503500

RE3503500

RE3783500

RE3783500

RE3783500

RE4053200

RE4053200

RE4163200

RE4163200

RE4293150

RE4293150

RE4293100

RE4293100

RE4293150

RE4293150

RE4562600

RE4562600

RE4562500

RE4562500

RE4293100

RE4293100

RE4293100

RE4293100

RE4462660

RE4562600

RE4552500

RE4552500

RE4293100

RE4293100

RE4293100

RE4462160

RE4462160

RE4562140

RE4293100

RE4293100

S05

S12

S15

S20

S30

S40

S50

S60

S41

S51

Size Model

Braking

Unit Rating Cat. No.

Duty Cycle 50 % 4)

Rating Cat. No.

Duty Cycle 20 % 4)

Power Supply 380-500 V AC 5)

Notes: 1) Series connected resistors. 2) Parallel connected resistors. 3) Refer SINUS PENTA Installation Manual for correct wiring of resistors and braking unit available at www.nhp.com.au/santerno. 4) 10 % duty cycle brake resistors also available. Contact NHP for further details. 5) 200-240 V AC (2T) resistors for all duty cycles (10 %, 20 %, 50 %) also available. Contact NHP for further details. Contact NHP for 690 V drive brake resistors.

505050505050505020202015151010108.58.56655101010101.11.11.11.11010101.11.11.11010

Min.

Resistance

11111111111111111122222233111144411255

Qty.

111111111111111111111133341111466111810

Qty.

* Power supply 660 - 690 V AC

3 - 38

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Dynamic braking allows a standard VSD to fully control the operation of the motor even when the motor acts as a generator. This can be the case when fast stopping times are required or the load has a high inertia. The use of a brake resistor allows the energy produced to be consumed, to avoid an alarm condition.

Drives up to frame S30 (132 kW) come standard with an integral brake module. In order to utilise this braking function, an external resistor is required. For larger sizes an external brake unit (BU200) is required.

The resistors in the table on page 3 - 34 are rated for full braking but need to be selected based on the required duty cycle of operation. There are three selections possible. These are 10 %, 20 % and 50 % to cover the wide range of applications and requirements.

Variable speed drivesBrake resistors

Rating

W

Dimensions (mm)

L H D

IP

Rating Cat. No. Price $

Description To suit Cat. No. Price $

Accessories

Adjustable thermal probe

BU200 380-500 V AC

BU1440 380-500 V AC

BU720 660-690 V AC

BU1440 660-690 V AC

BU700 380-500 V AC

IP 23 Resistors

S40-S60

S65+

S65

S65-S80

S41+S51

WW0030460

ZZ0063010

ZZ0063040

ZZ0063050

ZZ0063072

ZZ0063020

Ordering details

50 - 1100 W

50 - 1500 W

50 - 2200 W

15 - 4000 W

20 - 4000 W

25 - 4000 W

50 - 4000 W

50 - 4000 W

3.3 - 8000 W

10 - 8000 W

50 - 8000 W

6.6 - 12000 W

10 - 12000 W

20 - 12000 W

15 - 16000 W

10 - 24000 W

0.8 - 64000 W

1.2 - 48000 W

1.6 - 48000 W

6 - 48000 W

0.8 - 64000 W

1.2 - 64000 W

1.6 - 64000 W

2.4 - 64000 W

5 - 64000 W

IP 55

IP 54

IP 54

IP 20

IP 20

IP 20

IP 20

IP 23

IP 20

IP 20

IP 23

IP 20

IP 20

IP 23

IP 23

IP 23

IP 23

IP 23

IP 23

IP 23

IP 23

IP 23

IP 23

IP 23

IP 23

320

320

380

620

620

620

620

650

620

620

650

620

620

650

650

650

650

650

650

650

650

650

650

650

650

95

120

196

100

100

100

100

320

160

160

380

200

200

460

550

750

990

750

750

750

990

990

990

990

990

30

40

67

250

250

250

250

375

250

250

375

250

250

375

375

375

730

730

730

730

730

730

730

730

730

RE3083500

RE3093500

RE3113500

RE3483150

RE3483200

RE3483250

RE3483500

RE3503500

RE3762330

RE3763100

RE3783500

RE4022660

RE4023100

RE4053200

RE4163150

RE4293100

RE4561800

RE4462120

RE4462160

RE4462600

RE4561800

RE4562120

RE4562160

RE4562240

RE4562500

Price Schedule ‘M5’

0800 NHP NHP nhp-nz.com1300 NHP NHP nhp.com.au

Service Team

Our dedicated Service Team are on call, easy

to access, and are importantly experts in their

own right, able to understand the challenges

which need to be worked through to compete

and be successful in the global market.

Take the guesswork out of your project.

Think Sales Service and Support. Think NHP.

THINK SALES SERVICE AND SUPPORT. THINK NHP.NHP has the largest product management, technical and engineering support and sales team in the Australasian electrical industry available 24 hours a day, 7 days a week, 365 days a year.

3 - 40

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

0016 0017 0020 0025 0030 0034 0036

11 15 15 22 22 30 30

21 29 29 41 41 55 55

9 11 15 18.5 22 25 30

18 21 29 35 41 46 55

9 9 11 15 18.5 22 25

18 18 21 29 35 41 46

7.5 7.5 9.2 11 15 18.5 22

15 15 18 21 29 35 41

40 A 63 A 100 A

DTCB6340D DTCB6363D S125GJ/100

40 A 63 A 100 A

SLB40P3P SLB63P3P SLB100P3P

40 A 63 A 100 A

204122040 204122063 2041220100

65 A AC 1 100 A AC 1

CA 7-30 CA 7-60

32 A, 0.7 mH 43 A, 0.51 mH 68 A, 0.3 mH

IMO126084 IMO126124 IMO126144

32 A 64 A

AC1810302 AC1810402

50 , 2200 W 50 , 25 , 4000 W 15 , 4000 W 4000 W

RE3113500 RE3483500 RE3483250 RE3483150

50 , 8000 W 20 , 12000 W 20 ,16000 W

RE3783500 RE4053200 RE4163200

0005 0007 0009 0011 0014

4.5 5.5 7.5 7.5 7.5

9 11.2 14.5 14.8 14.8

4 4.5 5.5 7.5 7.5

8.4 9 11.2 14.8 14.8

3 4 4.5 5.5 7.5

6.4 8.4 9 11.2 14.8

2.2 3 4 4.5 5.5

4.9 6.4 8.4 9 11.2

16 A 25 A 32 A

DTCB6316D DTCB6325D DTCB6332D

20 A 25 A 32 A

SLB20P3P SLB25P3P SLB32P3P

16 A 25 A 40 A

204120416 204120425 204122040

32 A AC 1

CA 7-9

11 A, 2.0 mH 17 A, 1.27 mH

IMO126004 IMO126044

32 A

AC1810302

50 , 1100 W 50 , 1500 W

RE3083500 RE3093500

50 , 4000 W

RE3503500

380-415 V 50 HzS05 S12

Cat. No.SP_____4T BA2K2

Power (kW)

Current (A)

Power (kW)

Current (A)

Power (kW)

Current (A)

Power (kW)

Current (A)

Rating

Cat. No.

Rating

Cat. No.

Rating

Cat. No.

Rating

Cat. No.

Rating

Cat. No.

Rating

Cat. No.

Rating

Cat. No.

Rating

Cat. No.

Rating and selection chart

Standard duty rating (140 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty

Light duty rating (120 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty

Heavy duty rating (175 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty

Strong duty rating (200 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty

Recommended circuit breaker

Isolator switch

Recommended line contactor (Refer to Part A, section 1 for more information)

Input/output choke

Output EMC ferrite ring (for compliance to the first environment in addition to the built-in A2 filter)

Semi-conductor fuses

Dynamic brake resistor - 50 % duty cycle

Dynamic brake resistor - 20 % duty cycle

3 - 41

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

0113 0129 0150 0162

100 110 120 132

180 191 212 228

90 100 110 132

159 180 191 228

75 80 90 110

133 144 159 191

55 65 75 90

98 114 133 159

250 A 400 A

S250GJ/250 S400NJ/400

250 A 315 A 400 A

SLB2503P SLB3153P SLB4003P

250 A 315 A 400 A

2041220250 2041220315 2041220400

250 A AC1 350 A AC1

CA 6-140 CA 6-210

252 A, 0.09 mH

IM0126244

180 A 375 A

AC1810604 AC1811004

2 x 3.3 , 8000 W 2 x 10 , 12000 W

2 x RE3762330 2 x RE4023100

6 , 64000 W 5 , 64000 W

RE4562600 RE4562500

0040 0049 0060 0067 0074 0086

37 45 50 55 65 75

67 80 87 98 114 133

30 37 45 55 65 75

55 67 80 98 114 133

25 30 37 45 50 55

46 55 67 80 87 98

22 25 30 32 37 45

41 46 55 59 67 80

100 A 125 A 160 A

S125GJ/100 S125GJ/125 S160GJ/160

100 A 125 A 125 A 160 A 200 A

SLB100P3P SLB1253P SLB1253P SLB1603P SLB2003P

100 A 125 A 160 A 200 A

2041220100 2041220125 2041220160 2041220200

100 A AC1 160 A AC1

CA 7-60 CA 6-95

92 A, 0.24 mH 92 A, 142 A, 0.16 mH 0.24 mH

IM0126164 IM0126164 IM0126204

155 A 155 A

AC1810603 AC1810603

15 , 8000 W 10 , 12000 W 10 , 12000 W 10 , 16000 W

RE5783150 RE4023100 RE4023100 RE4163100

15 , 24000 W 10 , 24000 W 2 x 15 24000 W

RE4293150 RE4293100 RE4293150

S15 S20 S30

3 - 42

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

1 x 6.6 , 48000 W

1 x 6.0 , 64000 W

1 x 5.0 , 64000 W

1 x 1.6 , 48000 W

1 x 1.4 , 64000 W

Notes: 1) A brake unit BU200 is required for each resistor used. 2) Standard ACB + Basic OCR (AGR-11).

630 A

AC1811202

375 A

AC1811004

662 A, 0.033 mH

IM0126364

410 A, 0.054 mH

IM0126324

362 A, 0.061 mH

IM0126284

780 A AC1

CA 5-550

450 A AC1

CA 6-300

0180 0202 0217 0260 0313 0367 0402

160 200 220 250 280 315 400

273 341 375 425 480 528 680

150 160 220 250 280 315 400

264 273 375 425 480 528 680

132 160 185 220 250 280 355

228 273 321 375 421 480 589

110 132 150 185 200 220 280

191 228 260 321 341 375 480

Cat. No.SP_____4T XA2K2

Power (kW)

Current (A)

Power (kW)

Current (A)

Power (kW)

Current (A)

Power (kW)

Current (A)

Rating

Cat. No.

Rating

Cat. No.

Rating

Cat. No.

Rating

Cat. No.

Rating

Cat. No.

Rating

Cat. No.

Rating

Cat. No.

Rating

Cat. No.

630 A

S630CE/630

800 A

SLB8003P

800 A

2062232800

400 A

S400NJ/400

400 A

SLB4003P

500 A

SLB5003P

350 A

2041220350

550 A

2062232550

630 A

2062232630

1 x 3.0 , 48000 W

S41 S51380-415 V 50 Hz

630 A

S630CE/630

800 A

XS800NJ/800

800 A

SLB8003P

500 A AC1

CA 6-420

Rating and selection chart

500 A

2062232500

700 A

2062232700

1000 A

20622321000

945 A, 0.025 mH

IM0126404

RE4362360

1 x 3.6 , 32000 W

1 x 2.8 , 48000 W

1 x 2.4 , 48000 W

1 x 1.8 , 64000 W

2 x 2.8 , 48000 W

RE4462300 RE4462280 RE4462240 RE4562180 RE4462280

RE4462660 RE4562600 RE4552500 RE4462160 RE4562140

Light duty rating (120 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty

Standard duty rating (140 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty

Heavy duty rating (175 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty

Strong duty rating (200 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty

Isolator switch

Semi-conductor fuses

Recommended line contactor

Input / output choke

Output EMC ferrite ring (for compliance to the first environment in addition to the built-in A2 filter)

Dynamic brake resistor - 20 % duty cycle

Dynamic brake resistor - 50 % duty cycle

Recommended circuit breaker

3 - 43

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Notes: 1) A brake unit BU200 is required for each resistor used. 2) Standard ACB + Basic OCR (AGR-11).

1000 A AC1

CA 5-700

1000 A AC1

CA 5-700

0457 0524 0598 0748 0831 0964 1130 1296

400 450 500 560 710 900 1000 1170

680 765 841 939 1200 1480 1646 1950

400 450 500 560 630 800 900 1100

680 765 841 939 1080 1334 1480 1874

315 355 400 500 560 710 800 900

528 589 680 841 939 1200 1334 1480

280 315 355 400 450 560 710 800

480 528 589 680 765 939 1200 1334

1000 A

SLB10003P

1600 A

SLB16003P

1400 A

2063231400

1000 A

206223-21000

1250 A

206223-21250

945 A, 0.023 mH

IM0126404

945 A, 0.023 mH

IM0126404

S60 S65

2 x 1000 A

2 X 20632321000

2 x 1250 A

2 X 20632321250

2 x 1400 A

2 X 20632321400

2 x 800 A

2 X 206 3232800

1260 A, 0.018 mH

IM0126444

2 x 945 A, 0.023 mH input, 6 x 950 A, 0.024 mH output

2 x IM0126404 input, 6 x

IM0140674 output

5 x 10 , 12000 W

5 X RE40231001)

2 x 1.6 , 64000 W

2 X RE4562160

3 x 2.4 , 64000 W

3 X RE4562240

4 x 2.4 , 48000 W

4 X RE4462240

4 x 2.4 , 64000 W

4 X RE4562240

2 x 2.4 , 64000 W

2 X RE45622401)

1250 A

SLB12503P

800 A

XS800NJ/800

1000 A

XS1250SE/1000

1250 A

XS1250SE/1250 AR216S2) AR220S2) AR325S2) AR325S2)

2000 A

SLB20003P

2500 A

SLB25003P

1200 A AC1

CA 5-1000

2 x 945 A, 0.023 mH input, 6 x 1250 A, 0.018 mH output

2 x IM0126404 input, 6 x

IM0140774 output

2 x 1260 A, 0.018 mH input, 6 x 1250 A, 0.018 mH output

2 x IM0126444 input, 6 x

IM0140774 output

4 x 0.8 , 64000 W

4 X RE45618001)

8 x 1.6 , 48000 W

8 X RE44621601)

8 x 1.2 , 48000 W

8 X RE44621201)

8 x 1.2 , 64000 W

8 X RE45621201)

4 x 1.2 , 64000 W

4 X RE45621201)

10 x 10 , 24000 W

10 X RE42931001)

8 x 10 , 24000 W

8 X RE42931001)

S75

3 - 44

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘M5’

Variable speed drivesSINUS PENTA 660-690 V range and selection

S65Power supply 660-690 V AC

Inom = Inverter nominal continuous current ratingImax = Inverter maximum current for 60 sec every 10 minIpeak = Inverter maximum current for 5 sec

Light up to 120 % overloadStandard up to 140 % overload

Heavy up to 175 % overloadStrong up to 200 % overload

Size Cat. No.

Light Standard Heavy Strong Inom

A

Imax

A IpeakkW A kW A kW A kW A

S14

SP 0003 6TBA2K2 5.5 6.3 4 4.8 4 4.8 3 3.7 7 8.5 10SP 0004 6TBA2K2 7.5 8.4 5.5 6.3 4 4.8 4 4.8 9 11 13SP 0006 6TBA2K2 7.5 8.4 7.5 8.4 7.5 8.4 5.5 6.3 11 13.5 16SP 0012 6TBA2K2 11 12.1 7.5 8.4 7.5 8.4 7.5 8.4 13 16 19SP 0018 6TBA2K2 15 16.8 11 12.1 11 12.1 9.2 10.2 17 21 25SP 0019 6TBA2K2 15 16.8 11 12.1 11 12.1 9.2 10.2 21 25 30SP 0021 6TBA2K2 22 23 18.5 21 15 16.8 11 12.1 25 30 36SP 0022 6TBA2K2 30 33 22 23 22 23 18.5 21 33 40 48SP 0024 6TBA2K2 37 39 30 33 22 23 22 23 40 48 58SP 0032 6TBA2K2 45 46 37 39 37 39 30 33 52 63 76

S22

SP 0042 6TBA2K2 55 56 45 46 37 47 30 33 60 72 86SP 0051 6TBA2K2 75 78 55 56 55 56 45 46 80 96 115SP 0062 6TXA2K2 75 80 75 80 65 67 55 60 85 110 132SP 0069 6TXA2K2 90 95 90 95 75 80 55 60 100 130 156

S32

SP 0076 6TXA2K2 110 115 110 115 90 95 75 80 125 165 198SP 0088 6TXA2K2 132 140 132 140 110 115 90 100 150 200 240SP 0131 6TXA2K2 160 165 160 165 132 140 110 115 190 250 300SP 0164 6TXA2K2 200 205 200 205 160 165 132 140 230 300 360

S42

SP 0181 6TXA2K0 250 250 250 250 220 205 185 190 290 380 456SP 0201 6TXA2K0 315 310 315 310 250 250 220 220 330 420 504SP 0218 6TXA2K0 355 350 315 310 315 310 220 205 360 465 558SP 0259 6TXA2K0 400 390 400 390 355 341 315 310 400 560 672

S52

SP 0290 6TXA2K0 450 440 450 440 400 390 315 310 450 600 720SP 0314 6TXA2K0 500 480 450 450 450 440 355 341 500 650 780SP 0368 6TXA2K0 560 544 500 480 500 480 375 360 560 720 864SP 0401 6TXA2K0 630 626 630 626 560 544 450 440 640 850 1020

2 x S42 SP 0459 6TXA2K0 710 696 710 696 630 626 560 544 720 1000 1200

2 x S52

SP 0526 6TXA2K0 800 773 710 696 710 696 630 626 800 1050 1260SP 0600 6TXA2K0 900 858 800 773 800 773 630 626 900 1100 1320SP 0750 6TXA2K0 1000 954 1000 954 900 858 710 696 1000 1300 1560SP 0828 6TXA2K0 1200 1150 1100 1086 1000 954 800 773 1150 1440 1728

3 x S52SP 0960 6TXA2K0 1400 1360 1400 1360 1200 1150 1000 954 1400 1800 2160SP 1128 6TXA2K0 1650 1550 1400 1360 1400 1360 1000 954 1600 2000 2400

S75 SP 1130 6TXA2K0 1750 1700 1620 1569 1400 1360 1100 1086 1700 1700 2448S80 SP 1296 6TXA2K0 2010 1950 1850 1800 1610 1560 1380 1337 1950 2340 2528

3 - 45

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Ordering details - SINUS PENTA - 660-690 V IP 00

Variable speed drivesSINUS PENTA 660-690 V range and selection

Size

Dimensions (mm)

IPRating

Weight(kg)

Losses

at Inom (W) 1) Cat No. Price $W H D

S14 1) 1) 1)

IP 20 1) 1) SP 0003 6TBA2K2

IP 20 1) 1) SP 0004 6TBA2K2

IP 20 1) 1) SP 0006 6TBA2K2

IP 20 1) 1) SP 0012 6TBA2K2

IP 20 1) 1) SP 0018 6TBA2K2

IP 20 1) 1) SP 0019 6TBA2K2

IP 20 1) 1) SP 0021 6TBA2K2

IP 20 1) 1) SP 0022 6TBA2K2

IP 20 1) 1) SP 0024 6TBA2K2

IP 20 1) 1) SP 0032 6TBA2K2

S22 1) 1) 1)

IP 20 1) 1) SP 0042 6TBA2K2

IP 20 1) 1) SP 0051 6TBA2K2

IP 20 128 1300 SP 0062 6TXA2K0

IP 20 128 1450 SP 0069 6TXA2K0

S32 1) 1) 1)

IP 20 128 1700 SP 0076 6TXA2K0

IP 20 128 1950 SP 0088 6TXA2K0

IP 20 128 2300 SP 0131 6TXA2K0

IP 20 128 2750 SP 0164 6TXA2K0

S42 500 968 409

IP 00 128 3450 SP 0181 6TXA2K0

IP 00 128 3900 SP 0201 6TXA2K0

IP 00 136 4550 SP 0218 6TXA2K0

IP 00 136 4950 SP 0259 6TXA2K0

S52 578 968 409

IP 00 160 5950 SP 0290 6TXA2K0

IP 00 160 6400 SP 0314 6TXA2K0

IP 00 160 7000 SP 0368 6TXA2K0

IP 00 160 7650 SP 0401 6TXA2K0

S65 980 1400 560

IP 00 440 5000 SP 0250 6TXA2K0

IP 00 440 6100 SP 0312 6TXA2K0

IP 00 440 6900 SP 0366 6TXA2K0

IP 00 440 8000 SP 0399 6TXA2K0

IP 00 440 9150 SP 0457 6TXA2K0

IP 00 440 9800 SP 0524 6TXA2K0

IP 00 440 11250 SP 0598 6TXA2K0

IP 00 440 12450 SP 0748 6TXA2K0

S80 2230 1400 560IP 00 990 21900 SP 1130 6TXA2K0

IP 00 990 24000 SP 1296 6TXA2K0

Output Chokes - 660-690 V

Applicable size SP---6TXA2K0 Cat No. Price $

02500312-03990457-05980748-08310963-1130

1296

4106629451260

6 x 9006 x 1050

0.0930.0580.0400.0300.0580.040

300360360420TBATBA

290310390410TBATBA

220250270290TBATBA

IP 00IP 00IP 00IP 00IP 00IP 00

527988110TBATBA

58174611931438

6 x 4006 x 500

IM0127324

IM0127364

IM0127404

IM0127444

6 x IM0141724

6 x IM0141784

A mH

Rating

L H P

IP Rating

Weight (kg)

Losses at

Inom (W)Dimensions (mm)

Options to suit SINUS PENTA 6T models

Input Chokes - 660-690 VApplicable size SP---6TXA2K0 Cat No. Price $

02500312-03990457-0598

07480831096411301296

4106629451260

2 x 6622 x 9453 x 6623 x 1050

0.0930.0580.0400.0300.0580.0400.0580.040

300360360420360360360360

290310390410310390310390

220250270290250270250270

IP 00IP 00IP 00IP 00IP 00IP 00IP 00IP 00

527988110

2 x 792 x 883 x 793 x 88

58174611931438

2 x 7462 x 11933 x 7463 x 1193

IM0127324

IM0127364

IM0127404

IM0127444

2 x IM0127364

2 x IM0127404

3 x IM0127364

3 x IM0127404

A mH

Rating

L H P

IP Rating

Weight (kg)

Losses at

Inom (W)Dimensions (mm)

Notes: 1) Refer to NHP for data and availabilityPrice Schedule ‘M5’

3 - 46

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

The SINUS PENTA Variable Speed Drive when combined with special software becomes a high level integrated pump control system. This software can be added to any SINUS PENTA drive and is field loadable using the Remote Drive PC software package or can be supplied, pre-installed on request. The software provides a high level of control with flexible options for configuration, control and monitoring.

The multi-pump system can be used to control a system of up to 5 pumps including the master. The drive can be used to control this system without any additional hardware. The drive utilises the internal PID loop and control functionality to control the operation of not only the master but the slave drives also.

Variable speed drivesSINUS PENTA - Multi-pump application

Application software

SW Multi-pump operationOn-site commissioning and application support

Cat. No.

ZZ4590010

NHPSERVICE

Price $

Fixed speed operation

The fixed speed operation provides an economical Multi-pump solution where the master SINUS PENTA drive is used to control the process and the slaves are operated at fixed speed and bought on-line by the master when the capacity of the master is exceeded. When demand reduces, the master sheds the pumps off the system to maintain the process demand. A fixed speed system can be configured using a combination of Direct On-Line (DOL), Star-Delta or Soft Starters and connected using either standard I/O wiring or Modbus communication.

Variable speed operation

Variable speed operation allows for the most efficient and energy saving option for a pump system. By using variable speed drives on all pumps and varying their speed, the pumps can all be run at the lowest level to ensure the lowest energy usage level. As a result the operation of a variable system provides the same energy savings of a single pump, multiplied across all of the pumps. The master will determine which drives are required in order to maintain the demand based on user defined minimum and maximum operation levels. A complete variable speed system has the added benefit of providing a faster response to changing load conditions and is able to maintain a more stable system.

Multi-master control

In order to provide ultimate redundancy, the Multi-pump application incorporates Multi-master control. Multi-master control allows two drives to act as master and therefore the loss of the master will not effect the system operation. With Multi-master if the master becomes unavailable for use, control transfers to the second Multi-master. This allows the system to continue to function in the same way as if a slave was lost. The Multi-master drives operate continuously to calculate the required output even if the particular drive is not acting as the master at that time. This way it is always ready to take over the process with no interruption to operation. A combination of fixed and variable speed slaves can be used in this configuration.

Price Schedule ‘M5’SINUS PENTA MUP primary master with SINUS PENTA

secondary master and SINUS Micro slave

SINUS PENTA MUP master controllinga fixed speed DOL and AuCom soft starter

AC MAINS

FILLING

EMPTYING

FLOW

PRESSURE

P…n

P2

P1

Q

M2

M1

M…n

SLAVE 1

SLAVE 2

SINUS PENTAMUP MASTER

AC MAINS

FILLING

EMPTYING

FLOW

PRESSURE

P…n

P2

P1

Q

M2

M1

M…n

MUPSECONDARYMASTER

SLAVE 1

MUP PRIMARYMASTER

AC MAINS

FILLING

EMPTYING

FLOW

PRESSURE

P…n

P2

P1

Q

M2

M1

M…n

SLAVE 1

SLAVE 2

SINUS PENTAMUP MASTER

SINUS PENTA MUP master with SINUS Nanoand SINUS Micro variable speed slaves

3 - 47

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Price Schedule ‘M5’

Variable speed drivesSINUS PENTA - Regenerative application

The entire SINUS PENTA range of drives can be offered using an Active Front End (commonly referred to as an AFE) for use as a regenerative power supply system. It is defined as an AFE as the inverter becomes an active front end power supply unit that absorbs or sends sinusoidal current in the mains with unity power factor which has been regenerated from the load. The AFE has a stabilised direct voltage (DC link) as an output that is used to power one or more SINUS PENTA inverters through a direct DC connection. The AFE and the motor inverter drive are identical SINUS PENTA units except for the regenerative application software installed on the AFE inverter unit.

Inductances are used between the AFE and the power mains in order to filter the pulse width modulated (PWM) voltage on the inverter output terminals and to make the current exchanged with the mains sinusoidal. It is also necessary to use a line contactor and a regenerative interface which are supplied complete with capacitive filters.

Application software

Regenerative OperationOn-site commissioning and application support

Cat. No

ZZ4590010

NHPSERVICE

Price $

100 % braking torque is able to be absorbed by the AFE system making it perfectly suited for high inertia load applications such as:

• Lifts

• Conveyors

• Fans

• Centrifuges, etc.

which require fast deceleration times without the need for additional braking resistors and braking units.

When using braking resistors and braking units, this excess energy is dissipated in the form of heat which requires greater ventilation requirements and cabinet sizes. When using an AFE system, the excess energy is transferred through the AFE back into the mains grid connection which if properly monitored can save thousands of dollars in annual energy bills.

The use of a SINUS PENTA inverter as a regenerative unit has four main benefits over a standalone unit:

1. Unity power factor

2. Almost 0 % THD

3. 100 % braking torque

4. Line regeneration back into the grid

By the very nature of the AFE system using two inverters connected inversely to each other, the system is able to present to the mains power unity power factor which removes the need for additional power factor correction systems. In addition to this, requirements imposed by electricity distributors to minimise total harmonic distortion levels to levels generally <5 % are easily achieved using an AFE system without the need for additional harmonic filters hence saving significant savings in initial cost and cabinet space.

3 - 48

3

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Notes: 1) Kit includes metal cover with buttons and wiring loom. 2) Replace ‘xx’ with frame size number. 3) SINCOS and resolver/ encoder card with repeater available

Remote mounting kits

Remote mounting kit for keypad to IP 55 with a 3 m cableRemote mounting kit for keypad to IP 55 with a 5 m cable

ZZ0095699

ZZ0095700

Heatsink segregation kit for frame S05Heatsink segregation kit for frame S12

ZZ0095210

ZZ0121920

ES 847 I/O Expansion card (required for some special application software)8 digital inputs, 6 digital outputs and 4 analogue inputs or PT100This card mounts in the I/O slot within the drive.ES 870 I/O Expansion card12 digital inputs and 6 relay outputsThis card mounts in the I/O slot within the drive.ES 914 Isolated aux 24 V DC supply RS485

ZZ0101812

ZZ0101840

ZZ0101790

ES 822 Insulated card for RS 232 and/or RS 485 communication and is suggested for Modbus networks.

This card mounts in the communications slot within the drive.

ZZ0095850

These cards mount in the communications slot within the drive.

Profibus® DP card (kit hardware and software)DeviceNet™ card (kit hardware and software)Interbus card (kit hardware and software) CANOpen card (kit hardware and software) ControlNet card (kit hardware and software) Ethernet+IT card (kit hardware and software) Lonworks cardMetesys Nz cardBacNet 485 cardBacNet Ethernet cardES 851 Datalogger / energy monitor, WEB server, ethernet, modem

ZZ4600040

ZZ4600050

ZZ4600060

ZZ4600070

ZZ4600080

ZZ4600100

ZZ4600085

ZZ0102406

ZZ0102402

ZZ0102404

ZZ0101820

This card mounts in the encoder slot within the drive.

ES 836 Encoder card with internal 5-24 V encoder supply ZZ0095834 3)

Kit for use with remote drive software includes cable and USB/RS 485 converter. Download remote drive from www.nhp.com.au/santerno

SPUSB

A range of harmonic filters to suit all SINUS PENTA drives are availablewhich limits the THD to 5 %.Contact NHP for further information for correct selection.

Refer NHP

Potentiometer and start / stop pushbuttonsPotentiometer and forward / off / reverse selector switchEmergency stop and local / off / remote selector switchOther combinations available to suit the specific application

SP501- XX 2)

SP502- XX 2)

SP500- XX 2)

Encoder card

Description Cat. No. Price $

IP 54 customised control kits to suit SP --- 4T BA2K5 models 1)

Harmonic Filters

PC software kits

Communication option cards

Variable speed drivesSINUS PENTA - Options

I/O Expansion cards

Price Schedule ‘M5’

Added 24 V aux control supply and more comms cards

3 - 49

33

For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Power range: 2.2-1170 kW / 5 - 1950 A (4T)75 -2010 kW / 278 - 1950 A (6T)

Input voltage: AC Supply

DC Supply

4T - 380-500 V AC, 3 phase, - 15 % + 10 %6T - 525-690 V AC, 3 phase, - 15 % + 10 %4T - 530-705 V DC, -15 % + 10 %4T - 810-970 V DC, -15 % + 10 %

Input frequency: 50-60 Hz, +/- 10 %

Output voltage: 0-Vin + 2 %

Control system: IFD - V/f controlVTC - (open/closed loop) - Vector torque controlFOC - Field orientated closed loop controlRGN - Regenerative front end (option)MUP - Multipump application (option)

Overload current rating: In accordance with overload selected for 120 secs every 20 mins up to frame S30 and 60 secs every 10 mins for all other sizes.

Starting torque: Max 240 % for a short time and up to 200 % for 120 secs (dependent on overload selected)

Frequency/Speed resolution: 0.1 Hz IFD, 1 rpm VTC, 0.01 rpm FOC

Speed accuracy: Open loop + 0.5 % of max. speedClosed loop < 0.01 % of max. speed

Carrier frequency: 0.8 -16 kHz with silent mode, dependent on size and control typeBraking: 30 % DC braking

20 % dynamic braking without brake resistorUp to 150 % with internal brake module and external resistor (up to frame S30) or external brake unit and resistor for all other sizes.

Protection functions: Overcurrent, overvoltage, undervoltage, overload, inverter thermal protection, motor thermal protection, mains failure, communications error, auxiliary fault, encoder error.

Frequency setting: Digital keypad, external potentiometer, 0 to 10 V, 4 to 20 mA, preset speeds, up/down control, serial interface.

Control setting: Digital keypad, digital inputs, serial interfaceAnalogue inputs: 3 inputs, selectable between 0-10 V and 0 (4) - 20 mA (12 bit resolution)

Input AIN2 can also be used for PTC thermistor monitoring

Digital inputs: 8 inputs - 3 fixed, 5 programmable (multiple assignment possible)

Analogue outputs: 3 outputs, selectable between 0-10 V, -10-+10 V and 0 (4)-20 mA

Digital outputs: 1 push-pull transistor output (20-48 V DC, 50 mA max.)1 open collector transistor output (5-48 V DC, 50 mA max.)2 relay outputs with changeover contacts (250 V AC, 30 V DC, 3A)

Keypad: 4 line alphanumeric display 11 status LEDsDedicated keys for start, stop, fwd/rev, jog, reset, loc/rem, tx/rx

Enclosure protection: IP 20 from size S05 to size S40IP 00 from size S41 to size S80IP 54 from size S05 to Size S30

Environmental: 0 to +40 °C operation or to 50 °C with derating5 to 95 % RH non-condensing

Communication: Standard Optional

Modbus / RS 485Profibus®, DeviceNet™, Interbus, CANOpen, ControlNet, Ethernet, Lonworks, BacNet, NZ

EMC: AS 61800-3, category C3, second environment or Category C2, first environment with optional ferrite.

Safety: Safe torque off, SIL 3, to IEC standard.

Approvals:

Variable speed drivesSINUS PENTA Specifications

2 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Alp

han

um

eric

Ind

ex

CAT. NO. PAGE CAT. NO. PAGE CAT. NO. PAGE

1170H1007 3 - 8170H1007 3 - 11170H1007 3 - 20170H3003 3 - 8170H3003 3 - 11170H3003 3 - 20170H3004 3 - 20170M1314 3 - 8170M1314 3 - 11170M1314 3 - 20170M1316 3 - 20170M1317 3 - 8170M1317 3 - 11170M1318 3 - 8170M1318 3 - 11170M1318 3 - 20170M1319 3 - 8170M1319 3 - 11170M1319 3 - 20170M1321 3 - 8170M1321 3 - 11170M1321 3 - 20170M1322 3 - 8170M1322 3 - 11170M2621 3 - 20170M3022 3 - 8170M3022 3 - 11170M5011 3 - 20170M5015 3 - 20170M5017 3 - 20170M6008 3 - 20170M6009 3 - 20170M6010 3 - 20170M6011 3 - 20170M6013 3 - 20170M6015 3 - 20170M6017 3 - 20170M6018 3 - 20170M6019 3 - 20

220 412 04 16 3 - 3620 412 04 25 3 - 3620 412 20 100 3 - 3620 412 20 125 3 - 3620 412 20 160 3 - 3620 412 20 200 3 - 3620 412 20 250 3 - 3620 412 20 315 3 - 3620 412 20 350 3 - 3620 412 20 40 3 - 3620 412 20 400 3 - 3620 412 20 63 3 - 3620 622 32 1000 3 - 3620 622 32 1250 3 - 3620 622 32 500 3 - 3620 622 32 550 3 - 3620 622 32 630 3 - 3620 622 32 700 3 - 3620 622 32 800 3 - 3620 622 32 900 3 - 3620 632 32 1000 3 - 3620 632 32 1250 3 - 3620 632 32 1400 3 - 3620 632 32 800 3 - 3621 189 01 3 - 3621 313 02 3 - 3628 001 04 3 - 3628 002 02 3 - 36289-506 1 - 12

440.51 24 VDC 1 - 12

555150 2 - 955.1.50 2 - 1555151 2 - 955.1.51 2 - 1555152 2 - 955.1.52 2 - 1555164 2 - 955.1.64 2 - 1555.2.16 2 - 1555.2.17 2 - 15

55.2.37 2 - 1555.2.46 2 - 1555.1.50SS 2 - 1555.1.51SS 2 - 1555.1.52SS 2 - 1555153P 2 - 955.1.53P 2 - 1655.1.53RLR 2 - 1655.1.53RLR-PM 2 - 1655.1.64SS 2 - 1555.2.16GW 2 - 1555.2.16PL 2 - 1555.2.19NTW 2 - 1555.2.46SS 2 - 1555.4.00GWNBB 2 - 1455.4.00LHGWNBB 2 - 1455.4.00LHNBB 2 - 1455.4.00NBB 2 - 1455.4.00RHGWNBB 2 - 1455.4.00RHNBB 2 - 1455.4.01LHNBB 2 - 1455.4.01NBB 2 - 1455.4.01RHNBB 2 - 1455.4.01STRANBB 2 - 14554LVKIT 2 - 15

7750-300 1 - 21750-304 1 - 21750-305 1 - 21750-306 1 - 21750-310 1 - 21750-312 1 - 21750-313 1 - 21750-314 1 - 21750-315 1 - 21750-316 1 - 21750-319 1 - 21750-319/004-000 1 - 21750-320 1 - 21750-331 1 - 21750-333 1 - 21750-333/025-000 1 - 25750-334 1 - 21750-337 1 - 21750-337/025-000 1 - 25750-338 1 - 21750-339 1 - 21750-340 1 - 21750-341 1 - 21750-342 1 - 21750-343 1 - 21750-344 1 - 21750-345 1 - 21750-346 1 - 21750-347 1 - 21750-348 1 - 21750-350 1 - 21750-351 1 - 21750-370 1 - 21750-400 1 - 22750-400/025-000 1 - 25750-401 1 - 22750-402 1 - 22750-402/025-000 1 - 25750-403 1 - 22750-404 1 - 24750-405 1 - 22750-406 1 - 22750-408 1 - 22750-409 1 - 22750-410 1 - 22750-411 1 - 22750-412 1 - 22750-414 1 - 22750-415 1 - 22750-418 1 - 22750-421 1 - 22750-422 1 - 22750-423 1 - 22750-424 1 - 22750-425 1 - 22750-427 1 - 22750-428 1 - 22

750-430 1 - 22750-430/025-000 1 - 25750-431 1 - 22750-432 1 - 22750-433 1 - 22750-435 1 - 28750-436 1 - 22750-437 1 - 22750-438 1 - 28750-452 1 - 23750-453 1 - 23750-454 1 - 23750-454/025-000 1 - 25750-455 1 - 23750-455/025-000 1 - 25750-456 1 - 23750-457 1 - 23750-459 1 - 23750-460 1 - 23750-461 1 - 23750-465 1 - 23750-466 1 - 23750-466/025-000 1 - 25750-467 1 - 23750-468 1 - 23750-469/00000 1 - 23750-469/000001 1 - 23750-469/000002 1 - 23750-469/000003 1 - 23750-469/000006 1 - 23750-469/000008 1 - 23750-469/000012 1 - 23750-469/003000 1 - 23750-472 1 - 23750-473 1 - 23750-474 1 - 23750-475 1 - 23750-476 1 - 23750-477 1 - 23750-478 1 - 23750-479 1 - 23750-480 1 - 23750-481 1 - 28750-482 1 - 23750-483 1 - 23750-485 1 - 28750-491 1 - 23750-491/000-001 1 - 23750-492 1 - 23750-493 1 - 23750-493/000-001 1 - 23750-501 1 - 22750-502 1 - 22750-504 1 - 22750-504/025-000 1 - 25750-506 1 - 22750-508 1 - 22750-509 1 - 22750-511 1 - 24750-512 1 - 22750-513 1 - 22750-514 1 - 22750-516 1 - 22750-517 1 - 22750-519 1 - 22750-522 1 - 22750-523 1 - 22750-530 1 - 22750-530/025-000 1 - 25750-531 1 - 22750-532 1 - 22750-535 1 - 28750-536 1 - 22750-537 1 - 22750-550 1 - 23750-552 1 - 23750-553 1 - 23750-554 1 - 23750-555 1 - 23750-556 1 - 23750-557 1 - 23750-559 1 - 23750-560 1 - 23

3For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Alp

han

um

eric

Ind

ex

CAT. NO. PAGE CAT. NO. PAGE CAT. NO. PAGE

750-585 1 - 28750-600 1 - 24750-601 1 - 24750-602 1 - 24750-602/025-000 1 - 25750-603 1 - 24750-604 1 - 24750-609 1 - 24750-610 1 - 24750-611 1 - 24750-612 1 - 24750-613 1 - 24750-614 1 - 24750-615 1 - 24750-616 1 - 24750-621 1 - 24750-622 1 - 24750-623 1 - 24750-624 1 - 24750-625 1 - 28750-626 1 - 24750-627 1 - 24750-628 1 - 24750-630 1 - 24750-631/000-004 1 - 24750-634 1 - 24750-635 1 - 24750-636 1 - 24750-637 1 - 24750-638 1 - 24750-640 1 - 24750-641 1 - 24750-642 1 - 24750-643 1 - 24750-644 1 - 24750-645 1 - 24750-645 1 - 30750-650/003000 1 - 24750-651 1 - 24750-653/003000 1 - 24750-653/025-000 1 - 25750-653/025-018 1 - 25750-654 1 - 24750-655 1 - 24750-655 1 - 31750-655KIT 1 - 34750-660 1 - 29750-665 1 - 29750-666 1 - 29750-670 1 - 24750-671 1 - 24750-804 1 - 21750-806 1 - 21750-812 1 - 21750-812/025-000 1 - 25750-814 1 - 21750-815 1 - 21750-815/025-000 1 - 25750-816 1 - 21750-819 1 - 21750-830 1 - 21750-833 1 - 21750-833/025-000 1 - 25750-833KIT 1 - 34750-837 1 - 21750-838 1 - 21750-840 1 - 21750-841 1 - 21750-841/025-000 1 - 25750-841KIT 1 - 34750-842 1 - 21750-842KIT 1 - 34750-849 1 - 21750-860 1 - 21750-871 1 - 21750-873 1 - 21750-881 1 - 21750-920 1 - 25750-920 1 - 27750-920 1 - 33750-921 1 - 24750-921 1 - 25750-921 1 - 27

750-921 1 - 33750-923 1 - 25750-923 1 - 27750-923 1 - 33750-925 1 - 24750-925 1 - 30750-960 1 - 25750-961 1 - 25750-962 1 - 25750-963 1 - 25750-965 1 - 25750-970 1 - 25751-3001 1 - 31751-3002 1 - 31751-3501 1 - 31751-3502 1 - 31751-4001 1 - 31751-4501 1 - 31751-5201 1 - 31751-5202 1 - 31751-5701 1 - 31751-5702 1 - 31753-110 1 - 37753-150 1 - 37753-400 1 - 36753-401 1 - 36753-402 1 - 36753-403 1 - 36753-404 1 - 37753-405 1 - 36753-406 1 - 36753-408 1 - 36753-409 1 - 36753-410 1 - 36753-411 1 - 36753-412 1 - 36753-415 1 - 36753-418 1 - 36753-421 1 - 36753-422 1 - 36753-423 1 - 36753-424 1 - 36753-425 1 - 36753-427 1 - 36753-428 1 - 36753-430 1 - 36753-431 1 - 36753-432 1 - 36753-433 1 - 36753-434 1 - 36753-440 1 - 36753-452 1 - 37753-453 1 - 37753-454 1 - 37753-455 1 - 37753-456 1 - 37753-457 1 - 37753-459 1 - 37753-461 1 - 37753-465 1 - 37753-466 1 - 37753-467 1 - 37753-469 1 - 37753-472 1 - 37753-474 1 - 37753-475 1 - 37753-476 1 - 37753-477 1 - 37753-478 1 - 37753-479 1 - 37753-480 1 - 37753-482 1 - 37753-483 1 - 37753-492 1 - 37753-501 1 - 36753-502 1 - 36753-504 1 - 36753-506 1 - 36753-507 1 - 36753-509 1 - 36753-512 1 - 36753-513 1 - 36753-514 1 - 36

753-516 1 - 36753-517 1 - 36753-530 1 - 36753-531 1 - 36753-534 1 - 36753-540 1 - 36753-550 1 - 37753-552 1 - 37753-554 1 - 37753-556 1 - 37753-557 1 - 37753-559 1 - 37753-603 1 - 37753-604 1 - 37753-614 1 - 37753-635 1 - 37753-638 1 - 37753-646 1 - 37753-650 1 - 37753-653 1 - 37753-661 1 - 29753-662 1 - 29753-667 1 - 29758-912 1 - 24759-302 1 - 31759-302 1 - 33759-332 1 - 33759-333 1 - 3377.1.06 2 - 1977.1.10 2 - 1977.1.21 2 - 1977.1.25 2 - 1977.1.30 2 - 1977.1.31 2 - 1977.2.11 2 - 1977.2.34 2 - 1977.2.39 2 - 1977.2.40 2 - 1977.2.50 2 - 19787-602 1 - 25787-612 1 - 25787-692 1 - 25787-692 1 - 31

8810-900/000-001 1 - 25810-901/000-001 1 - 25810-902/000-001 1 - 25857-400 1 - 27857-411 1 - 27857-412 1 - 27857-420 1 - 27857-421 1 - 27857-423 1 - 27857-451 1 - 27857-452 1 - 27857-800 1 - 27857-801 1 - 27857-810 1 - 27857-811 1 - 27

9955-04938-00 3 - 2095AZB1 2 - 295AZB5 2 - 29950350300A 3 - 89950350300A 3 - 11995-04803-00 3 - 20995-04804-00 3 - 20995-06348-00 3 - 20995-08133-00 3 - 20

AACTWINCD 1 - 9ACTWINH 1 - 9ACTWINH 1 - 13ACTWINM1 1 - 9ADAPT1605 1 - 47ADROIT1500RC 1 - 66ADROIT1500SI 1 - 66ADROIT1500SI-A 1 - 66ADROIT150RC 1 - 66ADROIT150SI 1 - 66ADROIT150SI-A 1 - 66ADROIT25000RC 1 - 66ADROIT25000SI 1 - 66

4 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Alp

han

um

eric

Ind

ex

CAT. NO. PAGE CAT. NO. PAGE CAT. NO. PAGE

ADROIT25000SI-A 1 - 66ADROIT2500RC 1 - 66ADROIT2500SI 1 - 66ADROIT2500SI-A 1 - 66ADROIT300RC 1 - 66ADROIT300SI 1 - 66ADROIT300SI-A 1 - 66ADROIT30RC 1 - 66ADROIT30SI 1 - 66ADROIT30SI-A 1 - 66ADROIT5000RC 1 - 66ADROIT5000SI 1 - 66ADROIT5000SI-A 1 - 66ADROIT750RC 1 - 66ADROIT750SI 1 - 66ADROIT750SI-A 1 - 66ADROIT75RC 1 - 66ADROIT75SI 1 - 66ADROIT75SI-A 1 - 66ADROITULRC 1 - 66ADROITULSI 1 - 66ADROITULSI-A 1 - 66AL-210-MRA 1 - 4AL-210-MRD 1 - 4AL2-14AC-KIT 1 - 4AL2-14DC-KIT 1 - 4AL-214-MRA 1 - 4AL-214-MRD 1 - 4AL2-24AC-KIT 1 - 4AL2-24DC-KIT 1 - 4AL-224-MRA 1 - 4AL-224-MRD 1 - 4AL2-2DA 1 - 5AL2-2PT-ADP 1 - 4AL2-2TC-ADP 1 - 4AL-232-CAB 1 - 4AL2-4EX 1 - 5AL2-4EX-A2 1 - 5AL2-4EYR 1 - 5AL2-4EYT 1 - 5AL2-EEPROM-2 1 - 4AL2-GSM-CAB 1 - 4AL-DVD 1 - 4ALPHAGSMMODEM 1 - 4ALPHANXGMODEM 1 - 4ANT1 1 - 47AZM415202SA3D 2 - 5AZM415202SR3D 2 - 5AZM415 B1 2 - 5AZM415 B2 2 - 5AZM415 B3 2 - 5

BBZ1602D 2 - 7BZ1602U 2 - 7BZ1602V 2 - 7BZ1611D 2 - 7BZ1611U 2 - 7BZ1611V 2 - 7BZ16B1 2 - 7

CCBL-1509 1 - 9CBL-1509 1 - 13CBL-1509 1 - 54CBL90H 1 - 54CMR7110VA 3 - 6CMR712VDC 3 - 6CMR7230VA 3 - 6CMR724VA 3 - 6CMR724VDC 3 - 6CSX-007-V4-C1 3 - 8CSX-007-V4-C2 3 - 8CSX-015-V4-C1 3 - 8CSX-015-V4-C2 3 - 8CSX-018-V4-C1 3 - 8CSX-018-V4-C2 3 - 8CSX-022-V4-C1 3 - 8CSX-022-V4-C2 3 - 8CSX-030-V4-C1 3 - 8CSX-030-V4-C2 3 - 8CSX-037-V4-C1 3 - 8CSX-037-V4-C2 3 - 8CSX-045-V4-C1 3 - 8CSX-045-V4-C2 3 - 8

CSX-055-V4-C1 3 - 8CSX-055-V4-C2 3 - 8CSX-075-V4-C1 3 - 8CSX-075-V4-C2 3 - 8CSX-090-V4-C1 3 - 8CSX-090-V4-C2 3 - 8CSX-110-V4-C1 3 - 8CSX-110-V4-C2 3 - 8CSXI-007-V4-C1 3 - 11CSXI-007-V4-C2 3 - 11CSXI-015-V4-C1 3 - 11CSXI-015-V4-C2 3 - 11CSXI-018-V4-C1 3 - 11CSXI-018-V4-C2 3 - 11CSXI-022-V4-C1 3 - 11CSXI-022-V4-C2 3 - 11CSXI-030-V4-C1 3 - 11CSXI-030-V4-C2 3 - 11CSXI-037-V4-C1 3 - 11CSXI-037-V4-C2 3 - 11CSXI-045-V4-C1 3 - 11CSXI-045-V4-C2 3 - 11CSXI-055-V4-C1 3 - 11CSXI-055-V4-C2 3 - 11CSXI-075-V4-C1 3 - 11CSXI-075-V4-C2 3 - 11CSXI-090-V4-C1 3 - 11CSXI-090-V4-C2 3 - 11CSXI-110-V4-C1 3 - 11CSXI-110-V4-C2 3 - 11

DD32124000 1 - 47D38920000024 1 - 46D38920000115 1 - 46D38920000230 1 - 46D63696475024 1 - 47D63696475230 1 - 47DT01 1 - 47DT02 1 - 47DUPDATACC 1 - 47DUPSERVADD 1 - 47DUPSERVSW 1 - 47

EEEX GF1O1S 2 - 22EEX GFS1O1S 2 - 22EEXST-14-10/1S 5M 2 - 2EEXZS-71 10/1S WVD 2 - 9EEXZS-73 10/1S WVD 2 - 9EH-A14AS 1 - 7EH-A14DR 1 - 7EH-A14EDR 1 - 8EH-A20DR 1 - 7EH-A23DRP 1 - 7EH-A28AS 1 - 7EH-A28DR 1 - 7EH-A28DRP 1 - 7EH-A28EDR 1 - 8EH-A40DR 1 - 7EH-A4ERTD 1 - 8EH-A64DR 1 - 7EH-A64EDR 1 - 8EH-A6EAN 1 - 8EH-A6ERTD 1 - 8EH-AX44 1 - 13EH-AX8H 1 - 13EH-AX8I 1 - 13EH-AX8IO 1 - 13EH-AX8V 1 - 13EH-AXH8M 1 - 13EH-AY22 1 - 13EH-AY2H 1 - 13EH-AY4H 1 - 13EH-AY4I 1 - 13EH-AY4V 1 - 13EH-AYH8M 1 - 13EH-BS11 1 - 11EH-BS3 1 - 11EH-BS5 1 - 11EH-BS8 1 - 11EH-CB10 1 - 11EH-CBLCU 1 - 12EHCBLIN32 1 - 12EHCBLOUT32NPN 1 - 12

EHCBLOUT32PNP 1 - 12EH-CPU104 1 - 11EH-CPU208 1 - 11EH-CPU316 1 - 11EH-CPU516 1 - 11EH-CPU548 1 - 11EH-CU 1 - 12EH-CUE 1 - 12EH-D10DR 1 - 7EH-D10DTN 1 - 7EH-D10DTP 1 - 7EH-D14DR 1 - 7EH-D14DTN 1 - 7EH-D14DTP 1 - 7EH-D14DTPS 1 - 7EH-D14EDR 1 - 8EH-D14EDTN 1 - 8EH-D14EDTP 1 - 8EH-D14EDTPS 1 - 8EH-D16ED 1 - 8EH-D16ER 1 - 8EH-D16ETN 1 - 8EH-D16ETPS 1 - 8EH-D20DR 1 - 7EH-D20DTN 1 - 7EH-D20DTPS 1 - 7EH-D23DRP 1 - 7EH-D28DR 1 - 7EH-D28DRP 1 - 7EH-D28DTN 1 - 7EH-D28DTP 1 - 7EH-D28DTPS 1 - 7EH-D28EDR 1 - 8EH-D28EDTN 1 - 8EH-D28EDTP 1 - 8EH-D28EDTPS 1 - 8EH-D40DR 1 - 7EH-D40DTN 1 - 7EH-D40DTPS 1 - 7EH-D4ERTD 1 - 8EH-D64DR 1 - 7EH-D64DT 1 - 7EH-D64DTPS 1 - 7EH-D64EDR 1 - 8EH-D64EDT 1 - 8EH-D64EDTPS 1 - 8EH-D6EAN 1 - 8EH-D6ERTD 1 - 8EH-D8ED 1 - 8EH-D8EDR 1 - 8EH-D8EDTN 1 - 8EH-D8EDTPS 1 - 8EH-D8ER 1 - 8EH-D8ETN 1 - 8EH-D8ETPS 1 - 8EH-DUM 1 - 13EH-ETH2 1 - 11EH-IOCD 1 - 11EH-IOCH 1 - 11EH-IOCP 1 - 11EH-LINK 1 - 11EH-MBAT 1 - 9EH-MBATL 1 - 9EH-MBATLC 1 - 9EH-MCB01 1 - 8EH-MCB05 1 - 8EH-MCB10 1 - 8EH-MEMD 1 - 11EH-MEMP 1 - 11EH-OB232 1 - 8EH-OB232 1 - 9EH-OB485 1 - 8EH-OB485 1 - 9EH-OBMEM 1 - 9EH-OBUSB 1 - 9EH-OLINK 1 - 11EH-POS 1 - 13EH-POS4 1 - 13EH-PSA 1 - 11EH-PSD 1 - 11EH-PT4 1 - 13EHRLY16 1 - 12EH-RMD 1 - 11

5For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Alp

han

um

eric

Ind

ex

CAT. NO. PAGE CAT. NO. PAGE CAT. NO. PAGE

EH-RMP 1 - 11EH-SIO 1 - 11EH-TC8 1 - 13EHTRM32 1 - 12EH-XA16 1 - 12EH-XAH16 1 - 12EH-XD16 1 - 12EH-XD32 1 - 12EH-XD32E 1 - 12EH-XD64 1 - 12EH-XD8 1 - 12EH-XDL16 1 - 12EH-XDL32 1 - 12EH-XDL32E 1 - 12EH-YR12 1 - 12EH-YR16 1 - 12EH-YR8B 1 - 12EH-YS16 1 - 12EH-YS4 1 - 12EH-YT16 1 - 12EH-YT32 1 - 12EH-YT32E 1 - 12EH-YT64 1 - 12EH-YT8 1 - 12EH-YTP16 1 - 12EH-YTP16S 1 - 12EH-YTP32 1 - 12EH-YTP32E 1 - 12EH-YTP64 1 - 12EH-YTP8 1 - 12EM 40 GF KIT 2 - 22EM411O1S 2 - 12EM41D1O1S 2 - 12EM41DS1O1S 2 - 12EM41R1O1S 2 - 12EM41TL1O1S 2 - 12EM954K1O1S 2 - 11EM95D1O1S 2 - 11EM95DD1O1S 2 - 11EM95DS1O1S 2 - 11EM95R1O1S 2 - 11EM95TK1O1S 2 - 11EM95TL1O1S 2 - 11EM95W1O1S 2 - 11EMX3-0023B-V4-C1-H 3 - 16EMX3-0023B-V4-C1-H 3 - 17EMX3-0023B-V4-C2-H 3 - 16EMX3-0023B-V4-C2-H 3 - 17EMX3-0023B-V7-C1-H 3 - 18EMX3-0023B-V7-C1-H 3 - 19EMX3-0023B-V7-C2-H 3 - 18EMX3-0023B-V7-C2-H 3 - 19EMX3-0043B-V4-C1-H 3 - 16EMX3-0043B-V4-C1-H 3 - 17EMX3-0043B-V4-C2-H 3 - 16EMX3-0043B-V4-C2-H 3 - 17EMX3-0043B-V7-C1-H 3 - 18EMX3-0043B-V7-C1-H 3 - 19EMX3-0043B-V7-C2-H 3 - 18EMX3-0043B-V7-C2-H 3 - 19EMX3-0050B-V4-C1-H 3 - 16EMX3-0050B-V4-C1-H 3 - 17EMX3-0050B-V4-C2-H 3 - 16EMX3-0050B-V4-C2-H 3 - 17EMX3-0050B-V7-C1-H 3 - 18EMX3-0050B-V7-C1-H 3 - 19EMX3-0050B-V7-C2-H 3 - 18EMX3-0050B-V7-C2-H 3 - 19EMX3-0053B-V4-C1-H 3 - 16EMX3-0053B-V4-C1-H 3 - 17EMX3-0053B-V4-C2-H 3 - 16EMX3-0053B-V4-C2-H 3 - 17EMX3-0053B-V7-C1-H 3 - 18EMX3-0053B-V7-C1-H 3 - 19EMX3-0053B-V7-C2-H 3 - 18EMX3-0053B-V7-C2-H 3 - 19EMX3-0076B-V4-C1-H 3 - 16EMX3-0076B-V4-C1-H 3 - 17EMX3-0076B-V4-C2-H 3 - 16EMX3-0076B-V4-C2-H 3 - 17EMX3-0076B-V7-C1-H 3 - 18EMX3-0076B-V7-C1-H 3 - 19EMX3-0076B-V7-C2-H 3 - 18

EMX3-0076B-V7-C2-H 3 - 19EMX3-0097B-V4-C1-H 3 - 16EMX3-0097B-V4-C1-H 3 - 17EMX3-0097B-V4-C2-H 3 - 16EMX3-0097B-V4-C2-H 3 - 17EMX3-0097B-V7-C1-H 3 - 18EMX3-0097B-V7-C1-H 3 - 19EMX3-0097B-V7-C2-H 3 - 18EMX3-0097B-V7-C2-H 3 - 19EMX3-0100B-V4-C1-H 3 - 16EMX3-0100B-V4-C1-H 3 - 17EMX3-0100B-V4-C2-H 3 - 16EMX3-0100B-V4-C2-H 3 - 17EMX3-0100B-V7-C1-H 3 - 18EMX3-0100B-V7-C1-H 3 - 19EMX3-0100B-V7-C2-H 3 - 18EMX3-0100B-V7-C2-H 3 - 19EMX3-0105B-V4-C1-H 3 - 16EMX3-0105B-V4-C1-H 3 - 17EMX3-0105B-V4-C2-H 3 - 16EMX3-0105B-V4-C2-H 3 - 17EMX3-0105B-V7-C1-H 3 - 18EMX3-0105B-V7-C1-H 3 - 19EMX3-0105B-V7-C2-H 3 - 18EMX3-0105B-V7-C2-H 3 - 19EMX3-0145B-V4-C1-H 3 - 16EMX3-0145B-V4-C1-H 3 - 17EMX3-0145B-V4-C2-H 3 - 16EMX3-0145B-V4-C2-H 3 - 17EMX3-0145B-V7-C1-H 3 - 18EMX3-0145B-V7-C1-H 3 - 19EMX3-0145B-V7-C2-H 3 - 18EMX3-0145B-V7-C2-H 3 - 19EMX3-0170B-V4-C1-H 3 - 16EMX3-0170B-V4-C1-H 3 - 17EMX3-0170B-V4-C2-H 3 - 16EMX3-0170B-V4-C2-H 3 - 17EMX3-0170B-V7-C1-H 3 - 18EMX3-0170B-V7-C1-H 3 - 19EMX3-0170B-V7-C2-H 3 - 18EMX3-0170B-V7-C2-H 3 - 19EMX3-0200B-V4-C1-H 3 - 16EMX3-0200B-V4-C1-H 3 - 17EMX3-0200B-V4-C2-H 3 - 16EMX3-0200B-V4-C2-H 3 - 17EMX3-0200B-V7-C1-H 3 - 18EMX3-0200B-V7-C1-H 3 - 19EMX3-0200B-V7-C2-H 3 - 18EMX3-0200B-V7-C2-H 3 - 19EMX3-0220B-V4-C1-H 3 - 16EMX3-0220B-V4-C1-H 3 - 17EMX3-0220B-V4-C2-H 3 - 16EMX3-0220B-V4-C2-H 3 - 17EMX3-0220B-V7-C1-H 3 - 18EMX3-0220B-V7-C1-H 3 - 19EMX3-0220B-V7-C2-H 3 - 18EMX3-0220B-V7-C2-H 3 - 19EMX3-0255B-V4-C1-H 3 - 16EMX3-0255B-V4-C1-H 3 - 17EMX3-0255B-V4-C2-H 3 - 16EMX3-0255B-V4-C2-H 3 - 17EMX3-0255B-V7-C1-H 3 - 18EMX3-0255B-V7-C1-H 3 - 19EMX3-0255B-V7-C2-H 3 - 18EMX3-0255B-V7-C2-H 3 - 19EMX3-0255C-V4-C1-H 3 - 16EMX3-0255C-V4-C1-H 3 - 17EMX3-0255C-V4-C2-H 3 - 16EMX3-0255C-V4-C2-H 3 - 17EMX3-0255C-V7-C1-H 3 - 18EMX3-0255C-V7-C1-H 3 - 19EMX3-0255C-V7-C2-H 3 - 18EMX3-0255C-V7-C2-H 3 - 19EMX3-0350B-V4-C1-H 3 - 16EMX3-0350B-V4-C1-H 3 - 17EMX3-0350B-V4-C2-H 3 - 16EMX3-0350B-V4-C2-H 3 - 17EMX3-0350B-V7-C1-H 3 - 18EMX3-0350B-V7-C1-H 3 - 19EMX3-0350B-V7-C2-H 3 - 18EMX3-0350B-V7-C2-H 3 - 19EMX3-0360C-V4-C1-H 3 - 16EMX3-0360C-V4-C1-H 3 - 17

EMX3-0360C-V4-C2-H 3 - 16EMX3-0360C-V4-C2-H 3 - 17EMX3-0360C-V7-C1-H 3 - 18EMX3-0360C-V7-C1-H 3 - 19EMX3-0360C-V7-C2-H 3 - 18EMX3-0360C-V7-C2-H 3 - 19EMX3-0380C-V4-C1-H 3 - 16EMX3-0380C-V4-C1-H 3 - 17EMX3-0380C-V4-C2-H 3 - 16EMX3-0380C-V4-C2-H 3 - 17EMX3-0380C-V7-C1-H 3 - 18EMX3-0380C-V7-C1-H 3 - 19EMX3-0380C-V7-C2-H 3 - 18EMX3-0380C-V7-C2-H 3 - 19EMX3-0425B-V4-C1-H 3 - 16EMX3-0425B-V4-C1-H 3 - 17EMX3-0425B-V4-C2-H 3 - 16EMX3-0425B-V4-C2-H 3 - 17EMX3-0425B-V7-C1-H 3 - 18EMX3-0425B-V7-C1-H 3 - 19EMX3-0425B-V7-C2-H 3 - 18EMX3-0425B-V7-C2-H 3 - 19EMX3-0430C-V4-C1-H 3 - 16EMX3-0430C-V4-C1-H 3 - 17EMX3-0430C-V4-C2-H 3 - 16EMX3-0430C-V4-C2-H 3 - 17EMX3-0430C-V7-C1-H 3 - 18EMX3-0430C-V7-C1-H 3 - 19EMX3-0430C-V7-C2-H 3 - 18EMX3-0430C-V7-C2-H 3 - 19EMX3-0500B-V4-C1-H 3 - 16EMX3-0500B-V4-C1-H 3 - 17EMX3-0500B-V4-C2-H 3 - 16EMX3-0500B-V4-C2-H 3 - 17EMX3-0500B-V7-C1-H 3 - 18EMX3-0500B-V7-C1-H 3 - 19EMX3-0500B-V7-C2-H 3 - 18EMX3-0500B-V7-C2-H 3 - 19EMX3-0580B-V4-C1-H 3 - 16EMX3-0580B-V4-C1-H 3 - 17EMX3-0580B-V4-C2-H 3 - 16EMX3-0580B-V4-C2-H 3 - 17EMX3-0580B-V7-C1-H 3 - 18EMX3-0580B-V7-C1-H 3 - 19EMX3-0580B-V7-C2-H 3 - 18EMX3-0580B-V7-C2-H 3 - 19EMX3-0620C-V4-C1-H 3 - 16EMX3-0620C-V4-C1-H 3 - 17EMX3-0620C-V4-C2-H 3 - 16EMX3-0620C-V4-C2-H 3 - 17EMX3-0620C-V7-C1-H 3 - 18EMX3-0620C-V7-C1-H 3 - 19EMX3-0620C-V7-C2-H 3 - 18EMX3-0620C-V7-C2-H 3 - 19EMX3-0650C-V4-C1-H 3 - 16EMX3-0650C-V4-C1-H 3 - 17EMX3-0650C-V4-C2-H 3 - 16EMX3-0650C-V4-C2-H 3 - 17EMX3-0650C-V7-C1-H 3 - 18EMX3-0650C-V7-C1-H 3 - 19EMX3-0650C-V7-C2-H 3 - 18EMX3-0650C-V7-C2-H 3 - 19EMX3-0700B-V4-C1-H 3 - 16EMX3-0700B-V4-C1-H 3 - 17EMX3-0700B-V4-C2-H 3 - 16EMX3-0700B-V4-C2-H 3 - 17EMX3-0700B-V7-C1-H 3 - 18EMX3-0700B-V7-C1-H 3 - 19EMX3-0700B-V7-C2-H 3 - 18EMX3-0700B-V7-C2-H 3 - 19EMX3-0790C-V4-C1-H 3 - 16EMX3-0790C-V4-C1-H 3 - 17EMX3-0790C-V4-C2-H 3 - 16EMX3-0790C-V4-C2-H 3 - 17EMX3-0790C-V7-C1-H 3 - 18EMX3-0790C-V7-C1-H 3 - 19EMX3-0790C-V7-C2-H 3 - 18EMX3-0790C-V7-C2-H 3 - 19EMX3-0820B-V4-C1-H 3 - 16EMX3-0820B-V4-C1-H 3 - 17EMX3-0820B-V4-C2-H 3 - 16EMX3-0820B-V4-C2-H 3 - 17EMX3-0820B-V7-C1-H 3 - 18EMX3-0820B-V7-C1-H 3 - 19

6 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Alp

han

um

eric

Ind

ex

CAT. NO. PAGE CAT. NO. PAGE CAT. NO. PAGE

EMX3-0820B-V7-C2-H 3 - 18EMX3-0820B-V7-C2-H 3 - 19EMX3-0920B-V4-C1-H 3 - 16EMX3-0920B-V4-C1-H 3 - 17EMX3-0920B-V4-C2-H 3 - 16EMX3-0920B-V4-C2-H 3 - 17EMX3-0920B-V7-C1-H 3 - 18EMX3-0920B-V7-C1-H 3 - 19EMX3-0920B-V7-C2-H 3 - 18EMX3-0920B-V7-C2-H 3 - 19EMX3-0930C-V4-C1-H 3 - 16EMX3-0930C-V4-C1-H 3 - 17EMX3-0930C-V4-C2-H 3 - 16EMX3-0930C-V4-C2-H 3 - 17EMX3-0930C-V7-C1-H 3 - 18EMX3-0930C-V7-C1-H 3 - 19EMX3-0930C-V7-C2-H 3 - 18EMX3-0930C-V7-C2-H 3 - 19EMX3-1000B-V4-C1-H 3 - 16EMX3-1000B-V4-C1-H 3 - 17EMX3-1000B-V4-C2-H 3 - 16EMX3-1000B-V4-C2-H 3 - 17EMX3-1000B-V7-C1-H 3 - 18EMX3-1000B-V7-C1-H 3 - 19EMX3-1000B-V7-C2-H 3 - 18EMX3-1000B-V7-C2-H 3 - 19EMX3-1200C-V4-C1-H 3 - 16EMX3-1200C-V4-C1-H 3 - 17EMX3-1200C-V4-C2-H 3 - 16EMX3-1200C-V4-C2-H 3 - 17EMX3-1200C-V7-C1-H 3 - 18EMX3-1200C-V7-C1-H 3 - 19EMX3-1200C-V7-C2-H 3 - 18EMX3-1200C-V7-C2-H 3 - 19EMX3-1410C-V4-C1-H 3 - 16EMX3-1410C-V4-C1-H 3 - 17EMX3-1410C-V4-C2-H 3 - 16EMX3-1410C-V4-C2-H 3 - 17EMX3-1410C-V7-C1-H 3 - 18EMX3-1410C-V7-C1-H 3 - 19EMX3-1410C-V7-C2-H 3 - 18EMX3-1410C-V7-C2-H 3 - 19EMX3-1600C-V4-C1-H 3 - 16EMX3-1600C-V4-C1-H 3 - 17EMX3-1600C-V4-C2-H 3 - 16EMX3-1600C-V4-C2-H 3 - 17EMX3-1600C-V7-C1-H 3 - 18EMX3-1600C-V7-C1-H 3 - 19EMX3-1600C-V7-C2-H 3 - 18EMX3-1600C-V7-C2-H 3 - 19ES13SB101S 2 - 4ES 40 GF KIT 2 - 22ES41 2 - 12ES41D1O1S 2 - 12ES41DS1O1S 2 - 12ES41R1O1S 2 - 12ES41Z 101S 2 - 21ES 60 GF 2 - 22ES61SR101S 2 - 10ES954K1O1S 2 - 11ES95AZ101S 2 - 2ES95AZ20 2 - 2ES95D1O1S 2 - 11ES95DD1O1S 2 - 11ES95DS1O1S 2 - 11ES95R1O1S 2 - 11ES95SB101S 2 - 4ES95SB20 2 - 4ES95T5C101S 2 - 4ES95TK1O1S 2 - 11ES95TL1O1S 2 - 11ES95W1O1S 2 - 11ETHCONV2 1 - 46ETHCONV3 1 - 46EX55400GWNBB 2 - 14EX55400NBB 2 - 14EX55401NBB 2 - 14

GG21104401700 1 - 43G21205501700 1 - 43G21205502700 1 - 43G21305511700 1 - 44G21305521700 1 - 44

G21404421700 1 - 45G21404422700 1 - 45G21405510700 1 - 45G21405520700 1 - 45G32101111 1 - 46G32101112 1 - 46G32101113 1 - 46G32101161 1 - 46G32385138230 1 - 46G34105501 1 - 43G34205501024 1 - 43G34205501115 1 - 43G34205501230 1 - 43G34205501800 1 - 43G34205502024 1 - 43G34205502115 1 - 43G34205502230 1 - 43G34205502800 1 - 43G34296470024 1 - 46G34296470115 1 - 46G34296470230 1 - 46G34296470800 1 - 46G34301149024 1 - 44G34301149115 1 - 44G34301149230 1 - 44G34301149800 1 - 44G34302249024 1 - 44G34302249115 1 - 44G34302249230 1 - 44G34302249824 1 - 44G34304249024 1 - 44G34304249115 1 - 44G34304249230 1 - 44G34304249824 1 - 44G34304443024 1 - 44G34304443115 1 - 44G34304443230 1 - 44G34304443824 1 - 44G34304445024 1 - 44G34304445115 1 - 44G34304445230 1 - 44G34305511024 1 - 44G34305511115 1 - 44G34305511230 1 - 44G34305511800 1 - 44G34305521024 1 - 44G34305521115 1 - 44G34305521230 1 - 44G34305521800 1 - 44G34305545024 1 - 44G34305545115 1 - 44G34305545230 1 - 44G34396470024 1 - 46G34396470115 1 - 46G34396470230 1 - 46G34396470800 1 - 46G34404443024 1 - 45G34404443115 1 - 45G34404443230 1 - 45G34404443824 1 - 45G34485134230 1 - 44G34485234230 1 - 44G34485238230 1 - 44G34850000 1 - 47G34860058230 1 - 46G34900000024 1 - 42G34900000115 1 - 42G34900000230 1 - 42G34900000824 1 - 42G34910000024 1 - 46G34910000115 1 - 46G34910000230 1 - 46G34910040024 1 - 46G34910040115 1 - 46G34910040230 1 - 46G34910090024 1 - 46G34910090115 1 - 46G34910090230 1 - 46G34920000230 1 - 46G34930000230 1 - 46G34960000700 1 - 42G34960001700 1 - 42G34960002700 1 - 42

G34960003700 1 - 42G34960004700 1 - 42G34960005700 1 - 42G34960006700 1 - 42G34960007700 1 - 42G34960008700 1 - 42G34960009700 1 - 42G34960010700 1 - 42G34960011700 1 - 42G34960012700 1 - 42G38000015230 1 - 42G38000015800 1 - 42G38000016230 1 - 42G38000016800 1 - 42G38000036230 1 - 42G38000036800 1 - 42G38001015230 1 - 42G38001015800 1 - 42G38001016230 1 - 42G38001016800 1 - 42G38001036230 1 - 42G38001036800 1 - 42G38305543024 1 - 44G38305543115 1 - 44G38305543230 1 - 44G38305543824 1 - 44G38900014230 1 - 43G38900014800 1 - 43G38910020230 1 - 43G38910021230 1 - 43G38910050230 1 - 43G38910051230 1 - 43G38910052230 1 - 43G38910120230 1 - 43G40855562 1 - 47G41855531 1 - 47G42484134724 1 - 44G43111120 1 - 46G44207401230 1 - 43G44207401724 1 - 43G50101106 1 - 43G50102206 1 - 43G54606606024 1 - 47G54606606115 1 - 47G54606606230 1 - 47G61101145 1 - 43G61101145-1 1 - 43G63910240 1 - 46G81103394 1 - 46G81104406 1 - 45G81104407 1 - 45G81112211 1 - 46G81113315 1 - 46G81452574 1 - 45G81864407703 1 - 45G82104406 1 - 45G82452574 1 - 45G82864406703 1 - 45G85101101 1 - 45G85102201 1 - 45G85103301 1 - 45G86111010 1 - 46G88101102 1 - 43G88104401 1 - 43G88301143 1 - 44G88405521 1 - 45G89101101 1 - 43G89101101-G 1 - 43G89101127 1 - 43G89102116 1 - 43G89102217 1 - 43G89111010 1 - 46GAP1605 1 - 47GF 101S 2 - 22GF 10SD10S 2 - 22GF2 10S10S 2 - 22GF2 20S20S 2 - 22GF 2O2S 2 - 22GFM 101S 2 - 22GFM 202S 2 - 22GF POTI_OHM 2 - 22GFS 101S 2 - 22GFS 10SD10S 2 - 22

7For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Alp

han

um

eric

Ind

ex

CAT. NO. PAGE CAT. NO. PAGE CAT. NO. PAGE

GFS1SD 10VD 2 - 22GFS 202S 2 - 22GFS2 10S/10S 2 - 22GFS2 20S/20S 2 - 22GFS2SD 20VD 2 - 22GFSM 1O1S 2 - 22GFSM 2O2S 2 - 22GFS POTI_OHM 2 - 22GH34404412 1 - 45GH34850000724 1 - 46GH64404412 1 - 45GHTU8 1 - 47GPS-B015-FN4-VD 2 - 23GPS-B025-FN4-VD 2 - 23GPS-B045-FN4-VD 2 - 23GT01-C30R2-6P 1 - 5GT1030HBD2 1 - 5GTI50 1 - 46GTU8 1 - 47

HHSSI4101S 2 - 7HSSI420 2 - 7

IIM0126044 3 - 35IM0126084 3 - 35IM0126124 3 - 35IM0126144 3 - 35IM0126164 3 - 35IM0126204 3 - 35IM0126244 3 - 35IM0126284 3 - 35IM0126324 3 - 35IM0126364 3 - 35IM0126404 3 - 35IM0126444 3 - 35IM0127324 3 - 45IM0127364 3 - 45IM0127404 3 - 45IM0127444 3 - 456 X IM0141724 3 - 456 X IMO141782 3 - 356 X IM0141784 3 - 45IMO126004 3 - 35IPS-B026-FN4-VD 2 - 23IPS-B036-FN4-VD 2 - 23IPS-B046-FN4-VD 2 - 23

LLIBAT-H 1 - 13

MMC30 2 - 6MC4 2 - 7MC56 2 - 6MF1C 2 - 20

NNBAFP 2 - 15NBAG 2 - 15NBBFP 2 - 15NBBG 2 - 15NO2242 2 - 15NO2243 2 - 15NO2551 2 - 15NO2556 2 - 15NSC13DB24DA 2 - 20NSC13DB24DC 2 - 20

PPCNET 1 - 50PCNET 1 - 51PCNET 1 - 54PCP-064-480V 3 - 6PCP-064-600V 3 - 6PCP-147-480V 3 - 6PCP-147-600V 3 - 6PCS-003-480V 3 - 6PCS-003-480V-024V 3 - 6PCS-009-480V 3 - 6PCS-009-480V-024V 3 - 6PCS-016-480V 3 - 6PCS-016-480V-024V 3 - 6PCS-019-480V 3 - 6PCS-019-480V-024V 3 - 6PCS-025-480V 3 - 6PCS-025-480V-024V 3 - 6

PCS-030-480V 3 - 6PCS-030-480V-024V 3 - 6PCS-037-480V 3 - 6PCS-037-480V-024V 3 - 6PCS-043-480V 3 - 6PCS-043-480V-024V 3 - 6PCS-060-480V 3 - 6PCS-060-480V-024V 3 - 6PCS-085-480V 3 - 6PCS-085-480V-024V 3 - 6PCS-23-CI23 3 - 6PCS-25S-CC25 3 - 6PCS-37-CI37 3 - 6PCS-PA-01 3 - 6PCS-PA-10 3 - 6PCS-PA-11 3 - 6PCS-PA-20 3 - 6PCV-064 3 - 6PIM-DN-01 3 - 8PIM-DN-01 3 - 11PIM-DN-01 3 - 20PIM-MB-01 3 - 8PIM-MB-01 3 - 11PIM-MB-01 3 - 20PIM-PA-01 3 - 8PIM-PA-01 3 - 11PIM-PB-01 3 - 8PIM-PB-01 3 - 11PIM-PB-01 3 - 20PIM-RZ-01 3 - 8PIM-RZ-01 3 - 11PIM-USB-01 3 - 20PROTFILM10 1 - 54PROTFILM12 1 - 54PROTFILM6 1 - 54PS21LMS11P0M00 2 - 11PS21LMS11PRM00 2 - 11PS21LMS11R1M00 2 - 11PS21LMS11RTM00 2 - 11PS21LMT11P0M00 2 - 11PS21LMT11PRM00 2 - 11PS21LMT11R1M00 2 - 11PS21LMT11RTM00 2 - 11PS31LMS11P0T00 2 - 12PS31LMS11PRT00 2 - 12PS31LMS11R1T00 2 - 12PS31LMS11RTT00 2 - 12PS31LMS11RVT00 2 - 12PS31LMT11P0T00 2 - 12PS31LMT11PRT00 2 - 12PS31LMT11R1T00 2 - 12PS31LMT11RTT00 2 - 12PS31LMT11RVT00 2 - 12

RRCM-02 3 - 8RCM-02 3 - 11RCSI56101S5M 2 - 6RCSI56205M 2 - 6RCSIM30101S5M 2 - 6RCSIM30205M 2 - 6RE2643560 3 - 26RE2644100 3 - 26RE2644200 3 - 26RE2644400 3 - 26RE3063750 3 - 26RE3083500 3 - 26RE3083500 3 - 38RE3093500 3 - 38RE3113500 3 - 38RE3483150 3 - 38RE3483200 3 - 38RE3483250 3 - 38RE3483500 3 - 38RE3503500 3 - 38RE3762330 3 - 38RE3763100 3 - 38RE3783500 3 - 38RE4022660 3 - 38RE4023100 3 - 38RE4053200 3 - 38RE4163150 3 - 38RE4293100 3 - 38RE4462120 3 - 38

RE4462160 3 - 38RE4462600 3 - 38RE4561800 3 - 38RE4562120 3 - 38RE4562160 3 - 38RE4562240 3 - 38RE4562500 3 - 38RVT5009 1 - 50

SS900 2 - 9SC207A0101 1 - 48SM 0001 2ST BA2K2 3 - 25SM 0001 4T BA2K2 3 - 25SM 0002 2ST BA2K2 3 - 25SM 0002 4T BA2K2 3 - 25SM 0003 2ST BA2K2 3 - 25SM 0003 4T BA2K2 3 - 25SM 0005 2ST BA2K2 3 - 25SM 0005 4T BA2K2 3 - 25SM 0007 2ST BA2K2 3 - 25SM 0007 4T BA2K2 3 - 25SM 0011 2ST BA2K2 3 - 25SM 0011 4T BA2K2 3 - 25SM 0014 2ST BA2K2 3 - 25SM 0014 4T BA2K2 3 - 25SM 0017 2ST BA2K2 3 - 25SM 0017 4T BA2K2 3 - 25SM 0020 2ST BA2K2 3 - 25SM 0020 4T BA2K2 3 - 25SM 0025 2ST BA2K2 3 - 25SM 0025 4T BA2K2 3 - 25SM 0030 2ST BA2K2 3 - 25SM 0030 4T BA2K2 3 - 25SMDMK 3 - 26SME00022ST 3 - 26SME00024T 3 - 26SME00032ST 3 - 26SME00034T 3 - 26SME00072ST 3 - 26SME00074T 3 - 26SME00112ST 3 - 26SME00142ST 3 - 26SME00144T 3 - 26SN 0001 2S XB K2 3 - 24SN 0002 2S XB K2 3 - 24SN 0003 2S XB K2 3 - 24SN 0005 2S XB K2 3 - 24SNMCANOP 3 - 26SNMCTLNT 3 - 26SNMDEVNT 3 - 26SNMETHNT 3 - 26SNMINTBS 3 - 26SP 0313 4TXA2K0 3 - 33SP 0367 4TXA2K0 3 - 33SP 0402 4TXA2K0 3 - 33SP 0457 4TXA2K0 3 - 33SP 0524 4TXA2K0 3 - 33SP 0598 4TXA2K0 3 - 33SP 0748 4TXA2K0 3 - 33SP 0831 4TXA2K0 3 - 33SP 0964 4TXA2K0 3 - 33SP 1130 4TXA2K0 3 - 33SP 1296 4TXA2K0 3 - 33SP 0003 6TBA2K2 3 - 45SP 0004 6TBA2K2 3 - 45SP 0005 4TBA2K2 3 - 33SP 0005 4TBA2K5 3 - 34SP 0006 6TBA2K2 3 - 45SP 0007 4TBA2K2 3 - 33SP 0007 4TBA2K5 3 - 34SP 0009 4TBA2K2 3 - 33SP 0009 4TBA2K5 3 - 34SP 0011 4TBA2K2 3 - 33SP 0011 4TBA2K5 3 - 34SP 0012 6TBA2K2 3 - 45SP 0014 4TBA2K2 3 - 33SP 0014 4TBA2K5 3 - 34SP 0016 4TBA2K2 3 - 33SP 0016 4TBA2K5 3 - 34SP 0017 4TBA2K2 3 - 33SP 0017 4TBA2K5 3 - 34SP 0018 6TBA2K2 3 - 45SP 0019 6TBA2K2 3 - 45SP 0020 4TBA2K2 3 - 33

8 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Alp

han

um

eric

Ind

ex

CAT. NO. PAGE CAT. NO. PAGE CAT. NO. PAGE

SP 0020 4TBA2K5 3 - 34SP 0021 6TBA2K2 3 - 45SP 0022 6TBA2K2 3 - 45SP 0024 6TBA2K2 3 - 45SP 0025 4TBA2K2 3 - 33SP 0025 4TBA2K5 3 - 34SP 0030 4TBA2K2 3 - 33SP 0030 4TBA2K5 3 - 34SP 0032 6TBA2K2 3 - 45SP 0034 4TBA2K2 3 - 33SP 0034 4TBA2K5 3 - 34SP 0036 4TBA2K2 3 - 33SP 0036 4TBA2K5 3 - 34SP 0040 4TBA2K2 3 - 33SP 0040 4TBA2K5 3 - 34SP 0042 6TBA2K2 3 - 45SP 0049 4TBA2K2 3 - 33SP 0049 4TBA2K5 3 - 34SP 0051 6TBA2K2 3 - 45SP 0060 4TBA2K2 3 - 33SP 0060 4TBA2K5 3 - 34SP 0062 6TXA2K0 3 - 45SP 0067 4TBA2K2 3 - 33SP 0067 4TBA2K5 3 - 34SP 0069 6TXA2K0 3 - 45SP 0074 4TBA2K2 3 - 33SP 0074 4TBA2K5 3 - 34SP 0076 6TXA2K0 3 - 45SP 0086 4TBA2K2 3 - 33SP 0086 4TBA2K5 3 - 34SP 0088 6TXA2K0 3 - 45SP 0113 4TBA2K2 3 - 33SP 0113 4TBA2K5 3 - 34SP 0129 4TBA2K2 3 - 33SP 0129 4TBA2K5 3 - 34SP 0131 6TXA2K0 3 - 45SP 0150 4TBA2K2 3 - 33SP 0150 4TBA2K5 3 - 34SP 0162 4TBA2K2 3 - 33SP 0162 4TBA2K5 3 - 34SP 0164 6TXA2K0 3 - 45SP 0180 4TXA2K0 3 - 33SP 0181 6TXA2K0 3 - 45SP 0201 6TXA2K0 3 - 45SP 0202 4TXA2K0 3 - 33SP 0217 4TXA2K0 3 - 33SP 0218 6TXA2K0 3 - 45SP 0250 6TXA2K0 3 - 45SP 0259 6TXA2K0 3 - 45SP 0260 4TXA2K0 3 - 33SP 0290 6TXA2K0 3 - 45SP 0312 6TXA2K0 3 - 45SP 0314 6TXA2K0 3 - 45SP 0366 6TXA2K0 3 - 45SP 0368 6TXA2K0 3 - 45SP 0399 6TXA2K0 3 - 45SP 0401 6TXA2K0 3 - 45SP 0457 6TXA2K0 3 - 45SP 0524 6TXA2K0 3 - 45SP 0598 6TXA2K0 3 - 45SP 0748 6TXA2K0 3 - 45SP 1130 6TXA2K0 3 - 45SP 1296 6TXA2K0 3 - 45SP500- XX 3 - 48SP501- XX 3 - 48SP502- XX 3 - 48SPUSB 3 - 26SPUSB 3 - 48SRM21RT2 2 - 20ST14-10/1S 2 - 2ST14-20 2 - 2ST14 B1 2 - 2ST14 B3 2 - 2ST14 B5 2 - 2ST6110/1S 2 - 3ST6120 2 - 3ST61 B1 2 - 3ST61 B5 2 - 3STM295202SA 2 - 5STM295202SR 2 - 5STM295 B1 2 - 5STM295 B5 2 - 5SYCON 1 - 13

TTQ4410101YU 2 - 21TQ441 01/01 YUR 2 - 9TQ441 01/01 YUR 137 2 - 9TQ441 01/01 YUR 157 2 - 9TQZ-73 20 WVD 2 - 9TQZS-70 10/1S VD 2 - 9TQZS70KIT10M 2 - 8TQZS-71 10/1SWVD 2 - 9TQZS-71 20 WVD 2 - 9TQZS71KIT20M 2 - 8TQZS-73 10/1SWVD 2 - 9TQZS73KIT50M 2 - 8TQZS-75 10/1S WVD 2 - 9TQZS-75 20/2S WVD 2 - 9TQZS75KIT50M 2 - 8TQZS-80 20/2S WVD 2 - 9TQZS80KIT50M 2 - 8TQZSTS150N 2 - 9TQZSTS250N 2 - 9

UUSB-COM 1 - 4USB-COM 1 - 5USB-COM 1 - 9USB-COM 1 - 13

VVFBC 2 - 15VT050 1 - 50VT060 1 - 50VT150W 1 - 50VT150W DP 1 - 50VT155W 1 - 52VT155W 000DP 1 - 52VT155W 000ET 1 - 52VT160W 1 - 50VT160W DP 1 - 50VT170W A 1 - 50VT185W 1 - 52VT185W 000ET 1 - 52VT190W A 1 - 50VT190W AP 1 - 50VT300W A 1 - 51VT300W AP 1 - 51VT310W A 1 - 51VT310W AP 1 - 51VT320W A 1 - 51VT320W AP 1 - 51VT330W APM 1 - 51VT330W APT 1 - 51VT505H 1 - 52VT505W 1 - 52VT505W 000ET 1 - 52VT505W DP 1 - 52VT515W 1 - 52VT515W 000DP 1 - 52VT515W 000ET 1 - 52VT525H 1 - 52VT525W 1 - 52VT525W 000DP 1 - 52VT525W 000ET 1 - 52VT555W A 1 - 52VT555W AP 1 - 52VT555W AP0DP 1 - 52VT560W A 1 - 53VT560W A0M 1 - 53VT565W A 1 - 53VT565W A0M 1 - 53VT565W AP 1 - 53VT565W APM 1 - 53VT580W 0PTDP 1 - 53VT580W 0PTET 1 - 53VT580W APT 1 - 53VT585W BPT 1 - 53VT585W BPTDP 1 - 53VT585W BPTET 1 - 53VT595W 0PTDP 1 - 53VT595W 0PTET 1 - 53VT595W APT 1 - 53VT5ESABUS 1 - 50VTBUTTONCELL 1 - 50VTBUTTONCELL 1 - 51VTBUTTONCELL 1 - 54VTCBL2515 1 - 54

VTCBL2545 1 - 54VTCBLADP 1 - 54VTCBLXFR 1 - 54VTPROFI/DP 1 - 50VTPROFI/DP 1 - 51VTPROFI/DP 1 - 54VTWINLITE 1 - 50VTWINLITE 1 - 51VTWINLITE 1 - 54

WWW0030460 3 - 38WW1420000 3 - 26

XXCSA120BC 1 - 68XCSA120CB 1 - 68XCSA120DC 1 - 68XCSB150C 1 - 68XCSB150D 1 - 68XCSBC 1 - 68XCSBD 1 - 68XCSD15B 1 - 68XCSD30C 1 - 68XCSD50B 1 - 68XCSD70C 1 - 68XCSF120B 1 - 68XCSF120CP 1 - 68XCSF120D 1 - 68XCSF240B 1 - 68XCSF240CP 1 - 68XCSF240D 1 - 68XCSF500C 1 - 68XCSF85CP 1 - 68XCSG2400C 1 - 68XCSG240C 1 - 68XCSG42 1 - 68XCSG500C 1 - 68XCSG720C 1 - 68XCSL120C 1 - 68XCSL240C 1 - 68XCSL85C 1 - 4XCSL85C 1 - 68XCSP120C 1 - 4XCSP120C 1 - 9XCSP120C 1 - 13XCSP85C 1 - 9XCSP85C 1 - 13XCSP85C 1 - 50XCSP85C 1 - 51XCSP85C 1 - 54

ZZS23211 2 - 22ZS73SR101S 2 - 10ZS75SR101S 2 - 10ZS75SR202S 2 - 10ZS90SR10S10S 2 - 10ZZ0063010 3 - 38ZZ0063020 3 - 38ZZ0063040 3 - 38ZZ0063050 3 - 38ZZ0063072 3 - 38ZZ0095210 3 - 48ZZ0095699 3 - 48ZZ0095700 3 - 48ZZ0095834 3 - 48ZZ0095850 3 - 48ZZ0101790 3 - 48ZZ0101812 3 - 48ZZ0101820 3 - 48ZZ0101840 3 - 48ZZ0102402 3 - 48ZZ0102404 3 - 48ZZ0102406 3 - 48ZZ0112010 3 - 35ZZ0112020 3 - 35ZZ0112030 3 - 35ZZ0112040 3 - 35ZZ0112045 3 - 35ZZ0112050 3 - 35ZZ0112060 3 - 35ZZ0112070 3 - 35ZZ0121920 3 - 48ZZ4590010 3 - 46ZZ4590010 3 - 47

9For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included

Alp

han

um

eric

Ind

ex

CAT. NO. PAGE

ZZ4600030 3 - 26ZZ4600040 3 - 48ZZ4600050 3 - 48ZZ4600060 3 - 48ZZ4600070 3 - 48ZZ4600080 3 - 48ZZ4600085 3 - 48ZZ4600100 3 - 48

1. Download

In order to scan one of the QR Codes

you need to download a QR Code

reader app to your smartphone. Try

simply searching ‘QR Code’ in your app

store.

2. Scan

Open your QR Code reader app and

point the device’s camera at the relevant

QR code.

3. View

Once scanned the QR Code will

automatically open the relevant

location.

HO

W T

O A

CT

IVA

TE

YO

UR

QR

CO

DE

S

WWEBQR CODE

With NHP’s Price Lists available for download online, you can now access product information anytime, anywhere!

Scan the QR code below or go to www.nhp.com.au to download the latest NHP catalogues and price lists.

34

VictoriaRichmond

Laverton

Dandenong

Albury / Wodonga

TasmaniaHobart

Launceston

New South WalesSydney

Newcastle

Canberra

Wollongong

Western AustraliaPerth

Northern TerritoryDarwin

QueenslandBrisbane

Townsville

Rockhampton

Toowoomba

Cairns

South AustraliaAdelaide

1 Ballarat

2 Bendigo

3 Geelong

4 Shepparton

5 Gippsland

6 Mildura

7 Whyalla

8 Mt Gambier

9 Kalgoorlie

10 Bunbury

11 Karratha

12 Port Hedland

13 Mackay

14 Gladstone

15 Sunshine Coast

16 Gold Coast

17 Griffith

18 Wagga Wagga

19 Dubbo

20 Gosford

21 Coffs Harbour

22 Tamworth

23 Lithgow

North IslandAuckland

Hamilton

Napier

Wellington

New Plymouth

South IslandChristchurch

Dunedin

24 Bay of Plenty

Cairns

Townsville

Rockhampton

Brisbane

NewcastleSydney

Wollongong

Auckland

Hamilton

LauncestonDandenongLaverton

12

3 5

67

13

14

15

16

17

18

19

20

2122

23

24

8

9

10

11 12

Adelaide

NHP Branch OfficesNHP Resident Sales Staff

Perth

Darwin

Melbourne

AlburyCanberra

Hobart

Napier

Wellington

Christchurch

Dunedin

Toowoomba

4

New Plymouth

Australian Branches

New Zealand Branches

Australian Regional Representation

New Zealand Regional Representation

NHP Electrical Engineering Products Pty LtdA.B.N. 84 004 304 812

NPLISTDC © Copyright NHP 2013

AUSTRALIAnhp.com.au

SALES 1300 NHP NHP

VICTORIAMelbourne

43-67 River Street Richmond VIC 3121 Tel +61 3 9429 2999

Laverton

104-106 William Angliss Drive Laverton North VIC 3026 Tel +61 3 9368 2901

Albury / Wodonga

847 Ramsden Drive Albury NSW 2640 Tel +61 2 6049 0600

Dandenong

40-42 Cyber Loop Dandenong South VIC 3175 Tel +61 3 8773 6400

TASMANIA

Hobart

Unit 2 65 Albert Street Moonah TAS 7009 Tel +61 3 6228 9575

Launceston

Unit 3 13-17 Merino Street Kings Meadows TAS 7249 Tel +61 3 6345 2600

NEW SOUTH WALESSydney

30-34 Day Street North Silverwater NSW 2128 Tel +61 2 9748 3444

Newcastle

575 Maitland Road Mayfield West NSW 2304 Tel +61 2 4960 2220

Wollongong

34 Industrial Road Unanderra NSW 2526 Tel +61 2 4272 5763

ACT

Canberra

Unit 1 187 Gladstone Street Fyshwick ACT 2609 Tel +61 2 6280 9888

WESTERN AUSTRALIA

Perth

38 Belmont Ave Rivervale WA 6103 Tel +61 8 9277 1777

NORTHERN TERRITORYDarwin

3 Steele Street Winnellie NT 0820 Tel +61 8 8947 2666

QUEENSLANDBrisbane

16 Riverview Place Murarrie QLD 4172 Tel +61 7 3909 4999

Townsville

5 Leyland Street Garbutt QLD 4814 Tel +61 7 4779 0700

Rockhampton

1 Lawson Street Parkhurst QLD 4702 Tel +61 7 4927 2277

Toowoomba

Cnr Carroll Street and Struan Court QLD 4350 Tel +61 7 4634 4799

Cairns Unit 2 1 Bramp Close Portsmith QLD 4870 Tel +61 7 4035 6888

SOUTH AUSTRALIA

Adelaide

36-38 Croydon Road Keswick SA 5035 Tel +61 8 8297 9055

NEW ZEALANDnhp-nz.com

SALES 0800 NHP NHP

PO Box 62-009

Sylvia Park

Auckland 1644

New Zealand

Auckland

118a Carbine Road Mt Wellington 1060 Tel +64 9 276 1967

Hamilton

78 Rostrevor Street Hamilton 3204 Tel +64 7 849 0257

Napier

126 Taradale Road Onekawa 4110 Tel +64 6 843 6928

New Plymouth

2 Dean Place Waiwhakaiho 4312 Tel 0800 NHP NHP

Wellington

52 Victoria Street Lower Hutt 5010 Tel +64 4 570 0634

Christchurch

27 Iversen Terrace Waltham 8011 Tel +64 3 377 4407

Dunedin

30 Fox Street South Dunedin 9012 Tel 0800 NHP NHP