nicholas & associates, inc. - amazon s3 › nicholas_iplanr › new_schrum_memorial… ·...
TRANSCRIPT
LETTER OF TRANSMITTAL To: R.B. Construction 600 North Villa Avenue
Villa Park, IL 60181
WE ARE SENDING YOU: Attached Under Separate Cover via the following items: Shop Drawings Plans Specifications Samples Change Order Copy of Letter Contracts Other Copies Date No. Description
1 4.22.16 08310 Access Panels
THESE ARE TRANSMITTED AS CHECKED BELOW: For Approval Approved As Submitted Resubmit For Your Use Approved As Noted Furnish as Corrected As Requested Revise & Resubmit Return Corrected Prints For Review and Comment For Record & Construction For Bids Due
Remarks: Sincerely, Lucas Streich Copy To: File IF ENCLOSURES ARE NOT AS NOTED, PLEASE NOTIFY US IMMEDIATELY.
NNIICCHHOOLLAASS && AASSSSOOCCIIAATTEESS,, IINNCC.. 1001 Feehanville Drive Phone 847.394.6200 Mt. Prospect, IL 60056 Fax 847.394.6205
Date: April 22, 2016 Job No. 14158 Attn: John Zybko Re: Hoover-Schrum Memorial School District 157 New Schrum Memorial Middle School 485 165th Street Calumet City, IL 60403
Submittal Transmittal
ARCON Associates, Inc.
Page 1 of 1
PROJECT SD157 New Schrum Middle School14158
DATE SENT 4/12/2016
SUBJECT Submittal - 08310 Access Panel SUBMITTAL ID 08 30 00-001
TYPE Submittal TRANSMITTAL ID 0487
PURPOSE CONFORMS WITH DESIGN CONCEPT
VIA Info Exchange
SPEC SECTION: 08 30 00
FROM
NAME COMPANY EMAIL PHONE
Joel Koster ARCON Associates, Inc.
TO
NAME COMPANY EMAIL PHONE
Lucas Streich [email protected]
CONTENTSQUANTITY: 1 DATED: 4/12/2016 NUMBER:
DESCRIPTION:08310 - Access Panels - 4.12.16.pdf
ACTION:REMARKS:
LETTER OF TRANSMITTAL To: ARCON Associates, Inc. 2050 S. Finley Road Suite 40 Lombard, IL, 60148 WE ARE SENDING YOU: Attached Under Separate Cover via the following items: Shop Drawings Plans Specifications Samples Change Order Copy of Letter Contracts Other Copies Date No. Description
1 4.12.16 08310 Access Panels
THESE ARE TRANSMITTED AS CHECKED BELOW: For Approval Approved As Submitted Resubmit Copies for Approval For Your Use Approved As Noted Furnish as Corrected As Requested Returned for Corrections Return Corrected Prints For Review and Comment For Record & Construction For Bids Due
Remarks: Sincerely, Lucas Streich Project Manager Copy To: IF ENCLOSURES ARE NOT AS NOTED, PLEASE NOTIFY US IMMEDIATELY.
NNIICCHHOOLLAASS && AASSSSOOCCIIAATTEESS,, IINNCC.. 1001 Feehanville Drive Phone 847.394.6200 Mt. Prospect, IL 60056 Fax 847.394.6205
Date: April 12, 2016 Job No. 15162 Attn: Joel Koster Re: Hoover-Schrum Memorial Middle School District 157 New Schrum Memorial Middle School 485 165th Street Calumet City, IL 60403
NO RATED PANELS ARE NEEDED. THE SIZE OF THEACCESS PANEL SHALL BE AS SMALL AS POSSBILE BUTALLOW ACCESS NEEDED (FOR INSTANCE, IF HANDACCESS IS ONLY NEEDED THEN A SMALLER PANELCAN BE USED. IF SOMEONE NEEDS TO GET THEIRHEAD ABOVE CEILING, A LARGER PANEL IS NEEDED.
R B CONSTRUCTION INC600 North Villa Avenue Villa Park IL 60181-1771630-279-2800 FAX 630-279-8686
4/7/2016
Project: Schrum Memorial Middle School485 165th StreetCalumet City, IL. 60409
Submittal Information
Construction Manager: Architect: Nicholas & Associates Arcon1001 Feehanville Road 2050 South Findlay RoadMount Prospect, IL. Lombard, IL. 60148
Supplier: Manufacturer:Prestige JL Industries
Specification: 08310
Product:Access Panels
Special Notes:The specifications indicate 8”x8” fire rated panels and 12”x12” non-rated panels. The plan indicates 18”x18”. Please clarify. Also, the latching option in the specification states “By spanner head wrench”. This option is not available in a rated panel. Please review latching options on rated panels. There do not appear to be any rated panels in the locations shown on the reflected ceiling drawings. The rated panel is being submitted in the event a rated location is found or added.
Thank You,
John ZybkoProject ManagerRB Construction, Inc.
SUBMITTAL: MODEL TM™ FLUSH ACCESS PANELS PAGE 1 OF 2
Model TM for Masonry, Tile and Wallboard is an all purpose 16 gauge steel access door that affords fast and convenient access for inspection or service to vital components of plumbing, heating, air conditioning and/or electrical systems. The 1" frame flange adds rigidity and conceals the rough wall openings. The concealed hinged door is mounted to the frame and swings open for ease in servicing, and results in a door always closing square in place.
SPECIFICATIONS
Frame: 16 gauge steel with 1" wall flange.
Door: 16 gauge steel.
Finish: White powder coat paint.
Lock: Flush screwdriver-operated steel cam “ C” with 1 or more on each side.
TM 2424C W
__________ ______Lock (C Std Special
or Option Code) Finish
LATCH AND LOCK OPTIONS
Torx Head Hex Head Spanner Head Knob Cam
PAGE 2 OF 2
Optional Colors at Additional Cost - Samples Available
G-Gray R-Red B-Black/FBK Flat SI - Silver
S-Sand AB-AMS Beige SB-SC Flat Beige BR-Bronze
Approx. Ship Wt.
(lbs)Latch(es)
4 1
4 1
6 1
6 1
7 1
9 1
10 1
12 2
9 1
11 1
13 2
20 3
15 4
20 4
17 4
22 4
24 5
SUBMITTAL: FD™, FDSS™ & HGFD™ SERIES - FIRE RATED FLUSH ACCESS DOORS FOR 2 HR WALLS PG 1 OF 2
JL Industries’ innovative line of fire-rated access panels for every type of installation meets testing standards: UBC 43-7, UL10B, CAN/ULC-S104, ASTME152. Access panels are rated to 1-1/2 hours for 2 hour fire barriers for vertical surfaces in sizes up to 48” x 48” (24” x 48” HGFD). All models feature a 2” thick insulated door, slam latch with spring-assisted closer and welded-on masonry anchors. Minimum size 8” x 8”.
FD: Standard Panel (Wall)Frame & Trim: 16 gauge steel with a paintable 1” flange. Door: 2” thick, insulated 20 gauge steel with continuous hinge, universal lock.Finish: White powder coat.
FDSS: Stainless Steel (Wall)
Fire-Rating of FD, FDSS & HGFD:Wall Installation: 1-1/2 hour UL“B” label in a 2 hour fire barrier. Test # R13067-1CSFM: This product has been approved by the California State Fire Marshall (CSFM) pursuant to Section 13144.1 of the Califor-nia Health and Safety Code. See CSFM Listing No 3330-1223:101 for allowable values and/or conditions for use concern-ing material presented in this document. It is subject reexamination, revision and possible cancellation.
Detail of Wall Model
LATCH AND LOCK OPTIONS
- PAGE 2
WALL INSTALLATION 1-1/2 HOUR UL“B” LABEL IN A 2 HOUR FIRE BARRIER
Use “C” Dimension for Installation Without Wallboard LinerAdd 1-5/8” to “A” for 5/8” Wallboard Liner of Opening on 4 Sides
Top View
APPROXIMATE SHIPPING WEIGHT
In Pounds LATCH (ES)
FD FDSS HGFD
6 6 11 1
8 8 15 1
10 10 17 1
12 12 22 1
15 15 17 1
17 18 30 1
21 22 51 1
28 29 53 1
26 27 51 1
29 30 53 1
36 37 58 2
27 28 47 1
37 38 60 2
54 56 85 2
38 40 ——- 2
43 41 ——- 2
52 54 ——- 2
61 64 —-— 2
100 110 ------- 2
- FIRE RATED FLUSH ACCESS DOORS FOR 2 HR WALLS PAGE 2 OF 2
SEE SEPARATE SUBMITTALS FOR 1- 3 HOUR CEILINGS, 3 HOUR WALLS OR DOUBLE LEAF
DOORS
THIS DRAWING IS AN ILLUSTRATION ONLY -INSTALLATION CONDITIONS MAY VARY
Order Format: _____ - _____ _____ ____ -_____ Example: FD-1212UMI-BModel Width Height Lock (U Standard, UM, Optional
(FD, FDSS, FDG) UK& UMI Optional) Color
Optional Colors at Additional Cost - Samples Available
W-White R-Red B-Black/FBK Flat
S-Sand AB-AMS Beige SB-SC Flat Beige