Low cost polypropylenelevel switchHermetically moulded,double chamberMercury free operatedmicro switchDirect pump controlup to 1.1 kWAdjustable switch differentialLow specific weightof the floating body
Level switch from drinkingwater to sewageSuitable also for tanksand basinsFail-safe indication andpump control
SSwwiittcchh rraattiinngg::250 V AC, 16 ATTeemmppeerraattuurree::0 °C to +50 °CPPrreessssuurree::max. 1 barPPrrootteeccttiioonn::IP 68
NIVOFLOAT
Low cost level switchLimit switch or differentialswitch versionsAdjustable sensitivityAdjustable time delayHigh or low fail-safe modeAll wetted partsstainless steelCompact unit with twoindependent relaysSeparate probe andrelay unitRod probes up to 3 m
Conductive liquids withmin. 2 x10-5 S/cm conductivityFail-safe indication andpump controlChemical and water industry
SSwwiittcchh rraattiinngg::250 V AC, 16 APPoowweerr ssuuppppllyy::24 V AC/DC, 110, 230 V ACTTeemmppeerraattuurree::-20 °C to +200 °CPPrreessssuurree::max. 16 barPPrroocceessss ccoonnnneeccttiioonn::3/8", 1 1/2"PPrrootteeccttiioonn::IP 65, IP 20
NIVOCONT K
Operation withoutpower supplyMicro-switch separatedfrom the processAll wetted partsstainless steelSide or top mountingFixed or adjustableswitch differentialSubmersible versionsVarious process connectionsOperational check viaoptional testerExplosion-proof models
Liquids with min. 0.7 kg/dm3
densityFail-safe and control levelswitches in closed tanksPower stations, chemical,petrochemical andpharmaceutical industryBalance tanks on ships
SSwwiittcchh rraattiinngg::250 V AC, 10 ATTeemmppeerraattuurree::-20 °C to +250 °CPPrreessssuurree::max. 25 barPPrroocceessss ccoonnnneeccttiioonn::square and standardflanges, 2” threadPPrrootteeccttiioonn::IP 65AApppprroovvaallss:: ATEX II 1/2 G EEx dme IIC T6…T2Germanische LloydNorske Veritas
NIVOMAG
No moving partsSelf-cleaning formost mediaHigh immunity againstvibrationsStainless steeland ECTFE coated probesSolid rod extensionup to 3 mVarious output configurationsHigh or low fail-safe modePlastic, aluminium or stainless steel housing
Explosion-proofmodels
Most liquids with min. 0.5 kg/dm3 density andmax. 10000 mm2/s viscosityCorrosive, thick, turbulent,flowing liquids
PPoowweerr ssuuppppllyy::20-255 V AC20-60 V DC
TTeemmppeerraattuurree::-40 °C to +130 °CPPrreessssuurree::max. 40 bar
PPrroocceessss ccoonnnneeccttiioonn::1” or flanges orhygienic fittingsOOuuttppuutt:: 1 or 2 SPDT relays,2-wire AC or DC, transistor (PNP, NPN)PPrrootteeccttiioonn::IP 67 or IP 68AApppprroovvaallss:: ATEXII 1 G EEx ia IIC T4...T6Germanische Lloyd
NIVOSWITCH
2 or 3-wire submersibletransmitterStainless steel bodyVenting tube in cableUp to 200 m rangeReverse polarity protectionOptional lightning protectionAccuracy: 0.25 or 0.5%
Borehole transmitter for thewater industrySmall diameter pipesSewage water
PPoowweerr ssuuppppllyy::9-30 V DCTTeemmppeerraattuurree::-10 °C to +60 °COOuuttppuutt::4-20 mA or 0-10 VPPrrootteeccttiioonn:: IP 68AApppprroovvaallss::ATEX II 1 G EEx ia IIC T6
NIVOPRESS NP
FLOAT CONDUCTIVITY MAGNETICCOUPLING
Operation without powersupplyReed switches separatedfrom processWetted parts stainlesssteel or plasticUp to 5 switch pointsVertical adjustability of allswitch pointsVarious process connectionsExplosion-proof models
Liquids with min. 0.5 or 0.8 kg/dm3 densityMulti-point level switchin closed tanksChemicals with densevapour or gas layerabove the surfaceFoaming liquids
SSwwiittcchh rraattiinngg::250 V AC, 3 ATTeemmppeerraattuurree::-40 °C to +150 °CPPrreessssuurree::max. 25 barPPrroocceessssccoonnnneeccttiioonn::1” or 2” or flangesPPrrootteeccttiioonn::IP 65AApppprroovvaallss::ATEX II 2 G EEx d lIC T3...T6
NIVOPOINT
MAGNETICTRACKING
VIBRATION FORKFOR LIQUIDS
No moving partsSelf-cleaning formost mediaHigh immunity againstvibrationsStainless steel probesSolid rod extensionup to 3 mVarious output configurationsSelectable densityHigh or low fail-safe modePlastic, aluminium or stainless steel housingDust-Ex models
Granular material and powder with min.0.01 kg/dm3
bulk densityCorrosive, thick, turbulent,flowing liquids
PPoowweerr ssuuppppllyy::20-255 V AC20-60 V DCTTeemmppeerraattuurree::-40 °C to +130 °CPPrreessssuurree::max. 40 barPPrroocceessss ccoonnnneeccttiioonn::1", 1 1/2"OOuuttppuutt:: 1 or 2 SPDT relays,2-wire AC or DC, transistor (PNP, NPN)PPrrootteeccttiioonn::IP 67 or IP 68AApppprroovvaallss::ATEX II 1/2 D IP6X T160°C
NIVOSWITCH
VIBRATION FORKFOR SOLIDS
HYDROSTATIC
2-wire compacttransmitterStainless steel diaphragmAccuracy: min. 0.5%High overload capabilityLevel and pressure managementHARTExplosion-proof models
Most liquids and masses in tanks and vesselsChemicals with densevapour or gas layers above the surfaceFoaming liquidsViscous or corrosivematerials
PPoowweerr ssuuppppllyy:: 12-30 V DCTTeemmppeerraattuurree::-30 °C to +125 °CPPrreessssuurree:: max. 400 barOOuuttppuutt:: 4-20 mA, HARTPPrroocceessss ccoonnnneeccttiioonn:: 1 1/2" or flanges or hygienicfittingsPPrrootteeccttiioonn:: IP 65AApppprroovvaallss:: ATEX II 1 G EEx ia IIC T6...T4
NIVOPRESS DT
HYDROSTATIC
2-wire compacttransmitterAccuracy: ± 1 mmRigid or flexible probesup to 10 mWetted parts: stainless steel or plasticTwo floats: interface meteringPlug-in field indicatormodule32-point linearisationDistance, level and volume measurementHARTExplosion-proof models
Liquids with min. 0.5 kg/m3
densityChemicals, solvents,hydrocarbonsFlammable liquidsInterface meteringCustody transfer
PPoowweerr ssuuppppllyy:: 12-36 V DCTTeemmppeerraattuurree:: -40 °C to +130 °CPPrreessssuurree:: max. 25 barMMeeaassuurriinngg rraannggee:: 0.5-10 mOOuuttppuutt:: 4-20 mA, HARTPPrroocceessss ccoonnnneeccttiioonn:: 1", 2" or flangesPPrrootteeccttiioonn:: IP 67AApppprroovvaallss:: ATEX II 1G EEx ia IIB T6...T4II 2G EEx d IIB T6...T4II 1/2G EEx d ia IIB T6...T4
NIVOTRACK
MAGNETO-STRICTIVE
Two-wire compacttransmitterLow or high frequencyversionsHigh sensitivityRod or cable probes up to 20 mFully or partly insulatedprobesPlug-in field indicatormodule32-point linearisationDistance, level and volume measurementHARTExplosion-proof models
Liquids, powders, granuleswith εr > 1.5 relative dielectric constantChemicals with dense gaslayers above the surfaceViscose or corrosivemediumsHigh pressure, hightemperature or vacuum
PPoowweerr ssuuppppllyy:: 12-36 V DCTTeemmppeerraattuurree:: -30 °C to +200 °CPPrreessssuurree:: max. 40 barOOuuttppuutt:: 4-20 mA, HARTPPrroocceessss ccoonnnneeccttiioonn::1", 1 1/2" or flangesPPrrootteeccttiioonn:: IP 67AApppprroovvaallss:: ATEX II 1G EEx ia IIB T6
NIVOCAP
CAPACITIVE
Long service timeMotor shut-off featureFlexible couplingSealed bearingsHigh temperature rangeTrue fail-safe versionDust-Ex models
Granular material and powder withmin. 80 kg/m3 densityHigh or low fail-safeFeed, coal, sand, rocks,limestone, metals, rubber
PPoowweerr ssuuppppllyy::12 V DC, 24 V DC, 24 V AC,48 V AC, 115 V AC,230 V ACTTeemmppeerraattuurree::-50 °C to +400 °CPPrreessssuurree:: max. 2 barPPrroocceessss ccoonnnneeccttiioonn:: 1" BSP, 1 1/4" NPT, 1 1/2" BSPTOOuuttppuutt:: Relay (SPDT)PPrrootteeccttiioonn:: IP 66AApppprroovvaallss:: ATEX II 1/2 D EEx c T 100 °CII 1/2 D IP65 T 85 °C
NIVOROTA
ROTARY PADDLE
2- or 4-wire compacttransmitterNon-contact level meteringNarrow 5° beam angleTemperature compensatedExcellent signal processingvia QUEST+ softwarePP, PVDF, PTFE, stainlesssteel or foam facedtransducersPlug-in field indicatormoduleSecondary lightningprotectionHART, RS 485Power relay outputExplosion-proof models
Almost any liquids or freeflowing solidsLevel, volume and openchannel flowReliable measurement inchallenging applicationssuch as vapour/fumestirrer, foam with liquids or dusting during filling with solids
PPoowweerr ssuuppppllyy::2-wire: 12-36 V DC4-wire: 85-255 V AC
11.4-40 V DC, 3.6 W11.4-28 V AC, 4 VA
TTeemmppeerraattuurree::-30 °C to +100 °CPPrreessssuurree:: 0.3 to 3 barMMeeaassuurriinngg rraannggee::0.2 - 25 m for liquids0.6 - 60 m for solidsOOuuttppuutt:: 4-20 mA, relay,HART, RS 485PPrrootteeccttiioonn:: IP 67AApppprroovvaallss:: ATEX II 1 G EEx ia IIB T6II 1/2 D IP65 T130°C
EchoTREK
ULTRASONIC
No moving partsSelf-cleaning formost mediaStainless steelvibrating sectionSolid rod or flexible cableextension up to 20 mPlastic or aluminium housingSelectable densityHigh or low fail-safe modeSelectable switching delayDust-Ex models
Granular material and powder withmin. 0.05 kg/dm3 bulkdensityGrain, flour, plastic gran-ules, cement, fly ash, etc
PPoowweerr ssuuppppllyy::16-40 V AC / 19-55 V DC85-265 V AC / 120-375 V DCTTeemmppeerraattuurree::-40 °C to +160 °CPPrreessssuurree::max. 25 barPPrroocceessss ccoonnnneeccttiioonn::1 1/2"OOuuttppuutt:: Relay (SPDT) orelectronic switch (SPST)PPrrootteeccttiioonn::IP 67AApppprroovvaallss::ATEX II 1/2 D IP 65 T
NIVOCONT R
VIBRATION ROD
FEATURES
APPLICATIONS
SPECIFICATIONS
OPERATINGPRINCIPLE
PRODUCT
2- or 4-wire compacttransmitterNon-contact level meteringLow costNarrow 5° beam angleTemperature compensatedExcellent signal processingvia QUEST+ softwarePP, PVDF housingSecondary lightningprotectionHARTPower relay outputExplosion-proof models
Most liquids Level, volume and openchannel flowReliable measurement inchallenging applicationssuch as vapour/fumestirrer and foam with liquidsor dusting during filling with solidsWhere IP 68 is needed
PPoowweerr ssuuppppllyy::2-wire: 12-36 V DC4-wire: 11.4-40 V DC, 3.6 W
11.4-28 V AC, 4 VATTeemmppeerraattuurree::-30 °C to +60 °CPPrreessssuurree:: 0.3 to 3 barMMeeaassuurriinngg rraannggee::0.2 - 15 m for liquids0.5 - 60 m for solidsOOuuttppuutt:: 4-20 mA, relay,HART, RS485PPrrootteeccttiioonn:: IP 68, IP 65AApppprroovvaallss:: ATEX II 1G EEx ia IIB T6II 1D IP68 T130°C
EasyTREK
ULTRASONIC
![Page 2: Nivelco Catalog](https://reader031.vdocument.in/reader031/viewer/2022020423/568c33811a28ab02358cf771/html5/thumbnails/2.jpg)
Compact sizeGauge or absolute pressureFast output responseStandard plug typeconnectorWide range of processconnections and diaphragms4-20 mA outputPressure ranges: 0.6 to 400 barAccuracy: 0.25% or 0.5%
NIPRESS
PRESSURETRANSMITTER
Switch or transmitterFully temperaturecompensatedIP 67 or IP 68 versionsMetal or PP bodyMagnet or cableprogramming0.2-1 m or 0.4-6 m ranges
MICROSONAR
ULTRASONICPROXIMITY
SENSOR
Suitable interface for devices having 4-20 mA or on-off outputsCan power 2-wire transmittersInput: 4-20 mA or contactRelay (SPDT) outputEmpty / fill controlLimit, differential or window switch capabilitiesProgrammable dampingEx ia models
UNICONT PKK
CURRENTCONTROLLED
SWITCH
Dual channelUp to 4 relaysTransmitter power supply32-point linearisationVarious control algorithmsAuto tuning
UNICONT PMM, PMG
UNIVERSAL PROCESSCONTROLLER /
INDICATOR
2-wire compact transmitterPlug in type indicator andprogramming unitSensor: Pt 100Output: 4-20 mA, HARTMeasurment range:-50 to +600 °CResolution:0.1 °C up to 200 °CProbe length: up to 3 mStainless steel or plasticcoated versionsEx ia and Ex d models
THERMOCONT 400
TEMPERATUREINDICATOR /
TRANSMITTER
General indicatorFor 4-20 mA loop-use,without power supply4–20 mA to HART converterwith power supplyField and panel mountablePlastic/ metal housingScaleableEx ia and Ex d models
UNICONT 400
LOOPINDICATOR
Programmer, indicator andcontroller for transmitterswith HART protocolHighly informative Dot-Matrixdisplay back lightTank visualisationSimple 6-key programming1 to 15 input channelsTransmitter diagnosticcapabilitiesExplosion-proof models
Programmer, indicator andcontroller for singletransmitters and fortransmitter groups
PPoowweerr ssuuppppllyy::11.4-40 V DC, 11.4-28 V ACor 85-255 V ACTTeemmppeerraattuurree::-30 °C to +50 °CIInnppuutt ffrroomm ttrraannssmmiitttteerrss:: HARTOOuuttppuuttss,, iinntteerrnnaall::0 to 2: 4-20 mAcurrent loops0 to 4: SPDT relaysOOuuttppuuttss,, eexxtteerrnnaall::0 to 16: 4-20 mAcurrent loops0 to 64: SPDT relaysCCoommmmuunniiccaattiioonn wwiitthh hhoosstt:: RS 485PPrrootteeccttiioonn:: IP54 or IP65AApppprroovvaallss::ATEX II (1) G [EEx ia] IIB
MULTICONT *
CONTROLLER
2 wire TDR technologyDigital communicationAccuracy: ±5 mmHigh pressureHigh temperature rangeExtremely low dead bandWide range of probesExplosion-proof models
Level, volume or interfacemeasurement Liquids, powders, granuleswith εr > 1.4Medium with turbulentsurface, dense dust, vapouror pressurized gas layersabove the product surfaceFor all tank shapes, for narrow vesselsHeavy industrial applications
PPoowweerr ssuuppppllyy:: 24 V DC,PPrroodduucctt tteemmppeerraattuurree::-30 to +200 °CFFllaannggee tteemmppeerraattuurree::-30 to +200 °CPPrreessssuurree:: 0 to 40 barMMeeaassuurriinngg rraannggee::0 – 24 mOOuuttppuutt::4-20 mA, HARTPPrrootteeccttiioonn:: IP 65AApppprroovvaallss:: ATEX II 1G EEx ia IIC T6,II 1G EEx ia IIB T6,II 1/2D IP65 T100°C
MicroTREK
GUIDEDMICROWAVE
2- or 4-wire FMCWtechnologyTBF mode for low εrDigital communicationField indicator facilityHigh accuracy up to ± 1 mmHigh pressureHigh temperature rangeLow dead bandExplosion-proof models
Level or volumemeasurementLiquids, powders, granules with εr > 1.5Medium with dust, vapouror pressurized gas layersabove the product surfaceHeavy industrial applications
PPoowweerr ssuuppppllyy:: 24 V DC,24 V AC, 100-240 V ACFFllaannggee tteemmppeerraattuurree::-60 to +250 °CPPrreessssuurree::0 to 64 barMMeeaassuurriinngg rraannggee::up to 40 mOOuuttppuutt::4-20 mA (active or passive)HART, Profibus, FF, ModbusPPrrootteeccttiioonn:: IP 67AApppprroovvaallss:: ATEX II 1/2 G EEx ia IIC T6
PiloTREK
NON-CONTACT MICROWAVE
leve
g08a
0619
b
Nivelco Messtechnik GmbHA-2326 Maria Lazendorf
Alois Stumergasse 4Tel.: (43-2235) 47281Fax: (43-2235) 42184
E-mail: [email protected]
Nivelco Bohemia s.r.o.Drážní 7
CZ–62700 Brno-SlatinaTel.: (420-548) 217285Fax: (420-548) 217283
E-mail: [email protected]
SC Nivelco Tehnica Masurarii SRL.
540069 Tg-Mures, Str. Ion Creanga nr. 3/1
Tel.: (00-40) 40-265-306192Fax: (00-40) 40-265-306192
E-mail: [email protected]
Nivelco Poland Sp.z.o.o.ul. Chorzowska 44bPL–44100 Gliwice
Tel.: (48-32) 270 3701Fax: (48-32) 270 3832
E-mail: [email protected]
Nivelco Instruments India Pvt. Ltd.127, Damji Shamji Industrial Complex,
Off Mahakali Caves Road, Andheri(East), Mumbai – 400 093
Tel.: 91-22-26876050Fax: 91-22-26876050
E-mail: [email protected]
������������ ���������� ������������ �� –– ����NNIIVVEELLCCOO – 142092 ����, �.
������ (���. ���.),�����������, ��. 4, � . 424
Tel.: 7 985 960 43 88Fax: 7 501 443 28 22
E-mail: [email protected]
NIVELCO IPARI ELEKTRONIKA ZRT.H-1043 Budapes t , Dugon ics u . 11 .Tel.: (36-1) 8890-100 Fax: (36-1) 8890-200
[email protected]: sales @nivelco.com
www.nivelco.com