nodeb routine maintenance
TRANSCRIPT
Huawei Confidential. All Rights Reserved
NodeB operation and maintenance
ISSUE 1.0
2 Internal Use
ObjectivesObjectives
Upon completion of this course, you will be able to:
Master NodeB operation and maintenance system;
Master the alarm management system
3 Internal Use
ReferencesReferences
《 31026663- BTS3812E Routine maintenance )》
4 Internal Use
Chapter 1 O&M systemChapter 1 O&M system
Chapter 2 Alarm management systemChapter 2 Alarm management system
5 Internal Use
O&M SystemO&M System
Provides two operation modes GUI MML commands
Operations Software Management Equipment Maintenance Cell management Tracing Management Real time monitoring
6 Internal Use
O&M System O&M System
7 Internal Use
O&M System O&M System
8 Internal Use
O&M System operationsO&M System operations
Software management Upload and download data files
Upload and download data configuration file Upload maintenance log file Upload equipment archives file
Upgrade NodeB software Download NodeB software Activate NodeB software Activate RRU software Synchronize version
9 Internal Use
O&M System operationsO&M System operations
Upgrade NodeB BOOTROM Download NodeB BOOTROM Activate NodeB BOOTROM Activate RRU BOOTROM
Upgrade NodeB patch Download NodeB patch Activate NodeB patch
10 Internal Use
O&M System operationsO&M System operations
Equipment Maintenance List NodeB software version (LST VER/ LST SOFTWARE) Modify NodeB time (MOD TM) Modify password (MOD PWD) Reset NodeB (RST SYS) Display board state (DSP BRD) List active alarm (LST ALMAF) List board version (DSP BRDVER) Display E1/T1(STM-1) state (DSP E1/T1) (DSP STM1) Display E1/T1(STM-1) work mode Reset board (RST BRD) Add/delete board (ADD BRD, RMV BRD)
11 Internal Use
O&M System operationsO&M System operations
Cell management Query cell status (LST LOCELL) Query cell status (DSP LOCELL) Block/unblock cell (BLK CELL,UBL CELL) Audit resource (ADT RES)
12 Internal Use
O&M System operationsO&M System operations
Trace Iub Interface message Start/stop tracing Iub interface Browse traced message View explanation of traced message Save traced message Offline view traced message Set traced message window display
13 Internal Use
O&M System operationsO&M System operations
Performance test CPU/DSP occupancy Cell Service resource occupancy RTWP measurement RX frequency scanning Service resource occupancy
14 Internal Use
Chapter 1 O&M systemChapter 1 O&M system
Chapter 2 Alarm management systemChapter 2 Alarm management system
15 Internal Use
Alarm Management SystemAlarm Management System
Alarm Type Description
Fault Alarm Alarms generated due to hardware equipment fault or major
function exception can be cleared after handling. The system
will report cleared alarm indicating the fault is cleared. Fault
alarms' generation and clearance are of one-to-one
correspondence relationship. Generally, severity of fault
alarm is higher than that of event alarm.
Event Alarm Accidental alarm during equipment operation reflects the
transient state of equipment operation. It only indicates the
system is in alarm state at a certain time. There is no cleared
alarm for event alarms. And some event alarms are
generated periodically.
16 Internal Use
Alarm Management SystemAlarm Management System
Alarm Severity Description
Critical Alarm This type of alarm affects the services provided by the
system, so it must be handled at once. Even if the alarm is
generated out of working-hours, measures should be taken
at once. For example, when some equipment or resource is
completely unavailable, it is necessary to restore it.
Major Alarm The major alarm affects QoS, for example, the QoS of a d
evice or resource is impaired. It requires immediate handli
ng.
17 Internal Use
Alarm Management SystemAlarm Management System
Alarm Severity Description
Minor Alarm The minor alarm does not affect QoS. It requires h
andling at a proper time against potential faults.
Warning Alarm The warning shows a potential error that may
affect service .It may require handling in some
cases.
18 Internal Use
Alarm Management SystemAlarm Management System
Network Management Category Description
Power System Alarms of the power system (e.g. DC 48V) .
Environment System Alarms of equipment room environment (e.g.
temperature, humidity and door control) .
Signaling System Alarms of channel associated signaling and SS7.
Trunk System Alarms of trunk circuit and trunk board.
Hardware System Alarms of board device (e.g. clock, CPU) .
Software System Alarms of software.
Operation System Alarms generated during system operation.
Communication System Alarms of communication system.
QoS Alarms of QoS.
Processing Error other alarms
19 Internal Use
Alarm Management System Alarm Management System
Functions: Browse alarm information Query alarm information Maintain alarm information Set fault alarm reporting attribute Print/save alarm information
20 Internal Use