notice of assembly, utilisation and mainte- nance ...€¦ · for your safety and satisfaction,...

9
ME decor 16/9 PL+ 84 PL+ 110310 NOTICE OF ASSEMBLY, UTILISATION AND MAINTE- NANCE FIREPLACE INSERT DECOR 16/9.PL+ - 16/9.PL.DF+ DECOR 84.PL+ - 84.PL.DF+ EN

Upload: others

Post on 03-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NOTICE OF ASSEMBLY, UTILISATION AND MAINTE- NANCE ...€¦ · For your safety and satisfaction, entrust your installation to your installer/salesman. Nevertheless, ... - Assemble

ME decor 16/9 PL+ 84 PL+ 110310

NOTICE OF ASSEMBLY, UTILISATION AND MAINTE-

NANCEFIREPLACE INSERT

DECOR 16/9.PL+ - 16/9.PL.DF+DECOR 84.PL+ - 84.PL.DF+

EN

Page 2: NOTICE OF ASSEMBLY, UTILISATION AND MAINTE- NANCE ...€¦ · For your safety and satisfaction, entrust your installation to your installer/salesman. Nevertheless, ... - Assemble

2

NOTICE OF ASSEMBLY, UTILISATION AND MAINTENANCE OF THE ‘JIDE’ FIREPLACE INSERTREF. DECOR 16/9.PL+ DECOR 16/9.PL.DF+ DECOR 84.PL + DECOR 84.PL.DF+

Fuel: Wood (less than a maximum of 20 % humidity is advised).

Please read the entire notice carefully and keep it safe.For your safety and satisfaction, entrust your installation to your installer/salesman. Nevertheless, you can install your fireplace yourself. In that case, please read this document whose purpose is that of familiarising you with your JIDE fireplace insert.

Our liability is limited to the supply of the device. Its installation must be implemented in accordance with the instructions contained in the present notice and with local regulations, as well as with European Standard EN 13229. These regulations set the rules of installation, insulation and connection of closed wood-burning firepla-ces in new or old buildings, as well as regulations relating to fume extraction flues.I. INSTALLATION

The manner in which you install your ‘JIDE’ fireplace may have a decisive influence on your safety and on its correct functioning.

- Prior to installing the device it is necessary to ensure that the fume extraction flue is well sealed. If necessary, arrange for the flue to be first swept and ensure that its section makes it possible to connect it to the fireplace.- If possible, the section of the fume extraction flue shall be similar to that of the fireplace. If the section of the fume extrac tion flue is much larger than that of the output of the device, it is advisable to insert a tube into the flue over its entire height and to ensure that the connection is perfectly sealed. The connection is to be implemented according to the rules-of-the-art. It is necessary to monitor the condition of the existing fume extraction, but even more carefully to monitor the connection of the existing hose. A poor connec tion may cause an accident. Use only stainless steel hoses sui table for the application.- A flue employed for a fireplace insert is to have normal drau ght, that is to say that at maximum power the depression shall l ie between 10 and 20 Pa.- Take the precaution of protecting by means of ‘high tempera ture’ thermal insulation any combustible materials located close to the device. Since the temperature of the fumes in the fume extraction flue may reach 300° to 400°, it may trigger the combustion of non-insulated combusti ble materials.

Page 3: NOTICE OF ASSEMBLY, UTILISATION AND MAINTE- NANCE ...€¦ · For your safety and satisfaction, entrust your installation to your installer/salesman. Nevertheless, ... - Assemble

1 2 3 4 5 6

L M N M

3

- In order to improve the output of your fireplace, protect the upper back face, as well as the two side faces of the device by means of «high-temperature» thermal insulation.- Ensure that the fresh air inlets located on the sides and at the back of the device are not blocked.- Assemble the 4 feet, taking into account if wishing to install ventilation, to leave a minimum space of 210 millimetres under the device. The device must be integrated into the brickwork. ATTENTION! This device is supplied without ventilation (optional: kit ventilation). In order to avoid overheating of the device and to obtain satisfactory, it is mandatory to remove the hot air outlet plates on the upper part of the housing. Provide for the extraction of hot air via an aluminium flexible hose.

II. ELECTRICAL CONNECTION (Voltage: 220 V)

The connection to the variable speed drive is implemented according to the diagram below.

Input: brown L 3 M 6 output brown Input: blue N 5 M 4 output blue Input: yellow/green 1 2 : output

- The earth wire is to be connected to the fan.- The speed of the fan is controlled by a variable speed drive, making it possible to adapt the ventilation to your needs.

III. FANS (optionally 1 x 750 m³)

The ventilation must always function, at least on minimum of the flow. Machine Directives 89/392CE - 98/37/CE

Access to the fan for cleaning and maintenance.- Remove the vermiculite panels in the bottom of the apparatus and the gris. Remove the protection sheet. Remove the screwed of the ashtray and remove the ashtray Put the ventilation kit into the place. Refit the variuos components.

Attention! Prior to any dismantling for cleaning or maintenance of the fan, it is compulsory to cut off the current input.

The manufacturer declines any liability for accidents attributable to a failure of the user to implement correct refitting..

Page 4: NOTICE OF ASSEMBLY, UTILISATION AND MAINTE- NANCE ...€¦ · For your safety and satisfaction, entrust your installation to your installer/salesman. Nevertheless, ... - Assemble

4

BA

A :Décor 84 PL +: diamètre 125Décor 16-9 PL +: diamètre 125Décor 84 PL DF + : diamètre 150Décor 16-9 PL DF +: diamètre 150

IV. HOT AIR OUTLET

Our devices are equipped with 4 supplementary hot air outlets, making possible the distribution of air via flexible belts in rooms located in vicinity; Remove the outlet protection plate and fasten thereon the belt connection unions. Attention! Regardless of the power of the fans, the distance at which the air shall be pulsed is neverthe less limited.

VI. IGNITION

- Lift the door completely.- Put blocks of lights fire and small wood in the apparatus.- Ignite the fire and lower the door leaving a space of approximately 5 cm to ensure good draught and avoid the soiling of the cold glass. (Too low a temperature causes condensation which will deposit on the glass.)- After loading (door open) and when the fire is bright, gradually close the glass until it is completely closed.- In the event of bad pulling of chimney or bad wood qulity, raise the door 1 cm in order to ensure a sufficient air flow and a good fire starting.- In the case of poor draught or poor quality of wood (humid), leave the door slightly ajar to ensure an ade quate input of air and a good start of the fire.- If hot draught is insufficient (problem of repulsion), it is necessary to remove the baffle.- To ensure good functioning, do not remove ash from the fireplace completely; but leave a 2-3 cm layer of ash on the grid.- When the apparatus has a ventilator, you regulate the flow wished with the variable speed controler. The ventilator must always function.

V. AIR OF COMBUSTION

This apparatus is équipped with a external air instake system for combustion air (A).

The adjustement of the air inlet of combustion is carrfied out with the assistance of the lever (B), located on the right of the apparatus.

Positioned on the left, open completely the air inlet of combustion, primary air under the grib and secondary air by the holes on the back of the apparatus. In the center, the primary air inlet is closed. The apparatus finction only with the secondary air of combus tion. Positioned on the right, you close olmost completly the arrive of the combustion air.

Page 5: NOTICE OF ASSEMBLY, UTILISATION AND MAINTE- NANCE ...€¦ · For your safety and satisfaction, entrust your installation to your installer/salesman. Nevertheless, ... - Assemble

5

IMPORTANT!

THE DEVICE CAN ONLY FUNCTION WITH BOTH DOORS OPEN IN THE DOUBLE FACE VERSION

For raising and lowering the door, always use the raising system located at the bottom of the left hand chassisTo reload the fire with fuel it is compulsory to use the door! The side door is only used for cleaning the glass. After cleaning of the glass it is necessary to re-close the side door firmly since otherwise the side door may become forced open.

ATTENTION! In the case of utilisation of an ‘open fire’, provide a spark Shield. NEVER FUNCTION WITH THE DOOR OPEN 2-3 CM IN NORMAL UTILISATION

VII. CLEANING OF GLASS

Cleaning of glass is implemented with the door open sideways. Always introduce the fist via the bottom of the joggle in order to assist the rotation movement of the door.

Clean the glass with a cloth soaked in water with an addition of vine gar; suitable commercial products are also available. Do not use an abrasive sponge. Take care not to damage the joint on the periphery of the door. If necessary, it can be replaced.

VIII. ADVICE - REMINDER

- Implement an annual sweep in order to limit the deposits of tar in the fume extraction flue.- It is necessary to monitor the condition of cleanliness of the fan. An accumulation of dust causes an imbalance of the turbine and pushes the motor which may then burn out or become noisy. If necessary, clean it 2-3 times a year. For greater ease, remove the fan from its seat, but before doing so, ensure that the current input is cut off.- Once or twice a year depending on the amount of use, clean and grease the door sliding axles using a high temperature grease.- Panels of protection (vermiculite) of the heating element may crack without preventing normal functio ning of the device. Nevertheless, ensure that no part of it is missing. If it is, replace the damaged panel.

IX. TYPE OF FUEL

‘Wood’ Certain types of wood heat better than others. ‘Green’ wood contains a lot of water (approximately 50 %). Normally, ‘dry’ wood stored outside for18 to 24 months and well ventilated, still contains 15 to 20 % of water. Humid wood is more difficult to burn and has lower calorific value. Humid fumes have, inter alia, the disadvantages of reduced draught and of the formation of tar in the fume extraction flue and on cold surfaces (glass, etc...).

Page 6: NOTICE OF ASSEMBLY, UTILISATION AND MAINTE- NANCE ...€¦ · For your safety and satisfaction, entrust your installation to your installer/salesman. Nevertheless, ... - Assemble

6

Decor 84 PL+ Decor 84 PL DF+ Decor 16/9 PL+ Decor 16/9 PL DF+

3 kg - 4 kg 3 kg - 4 kg 3 kg - 4 kg 3 kg - 4 kg

1

2

3

4

5

6

7

89

11

12

10

13

ATTENTION! Never use as fuel either treated wood (e.g. painted wood) or any material generating gases harmful to the envi-ronment and which attack the fireplace components.

N.B. We cannot be held liable for faulty installation. This must be very careful and implemented according to the rules-of-the-art.

Complementary products used for installation must comply with local stipulations and regulations.

X. NOMENCLATURE

1. Exterior housing 2. Heating element 3. Connection to fume outlet 4. Compulsory hot air outlet 5. Complete door with silk screen-printed glass 6. Stop ambers, joined for plane 7. Baffle 8. External air inlet for combustion 9. Fan 10. Variable speed drive 11. Vermiculite panel 12. 4 adjustable feet 13. Air of convection input (underneath - side – back)

Preferably use wood from deciduous trees. ‘Hard’ wood varieties such as beech or oak, whose density is high, will burn longer than other varieties with a low density. The table which follows, lists the densities of several varieties of wood.

Hornbeam 400 300- 500 kg/m³ Pine 300 300- 400 kg/m³ Oak 380 300- 480 kg/m³ Poplar 250 300- 350 kg/m³ Beech 350 300- 450 kg/m³ Spruce 250 300- 350 kg/m³ Larch 300 300- 400 kg/m³ Acacia 250 300- 350 kg/m³ Birch 300 300- 400 kg/m³

Other fuels: Peat, briquettes.

Maximum dry wood consumption per hour.

Do not exceed the maximum loading of wood per hour if not you risk an overheating of the apparatus.

Page 7: NOTICE OF ASSEMBLY, UTILISATION AND MAINTE- NANCE ...€¦ · For your safety and satisfaction, entrust your installation to your installer/salesman. Nevertheless, ... - Assemble

7

XI. WARRANTY AGREEMENT

The warranty, which appears below, shall only be valid, if the device has been installed according to the rules-of-the-art and used according to the recommendations appearing in the notice of assembly and of utilisation supplied with the device.

The currency of the warranty is seven years from the date of delivery by the installer or the reseller and shall apply to the following parts:

- the heating element of the device,- the outside housing.

The warranty is limited to two years in respect of the following parts:

- fan, variable speed drive.

The following are excluded from the warranty:

- Internal consumable parts,- Air control,- Vermiculite panels,- Ash box and door joints,- Glass subject to shock or to excessively violent manipulation,- Normal wear and lack of maintenance,- Damage attributable to the choice of nominal power and to the fuels used,- Damage due to faulty installation and to abnormal fume extraction flue draught (maximum 20 Pa),- Damage due to lack of monitoring, or to improper or faulty use of the device.

Deliberate and permanent suspension of ventilation shall also entail the suspension of the warranty on the device.

By agreement, the costs of travel, transport, labour, packing and the consequences of the immobilisation of the device, due to the implementation of the warranty, shall be for the account of the customer.The warranty shall only be able to be implemented through the reseller on the submission of the purchase invoice.---------------------------------------------------------------------------------------------------------------------------------------MODEL ‘JIDE’: DATE OF PURCHASE

PURCHASER Name: Given name: Address:

Post code: Town:

Page 8: NOTICE OF ASSEMBLY, UTILISATION AND MAINTE- NANCE ...€¦ · For your safety and satisfaction, entrust your installation to your installer/salesman. Nevertheless, ... - Assemble

8

ADVICE IN CASE OF IRREGULARITIES AND DYSFUNCTIONS

PROBLEM FOUND POSSIBLE CAUSES REMEDIES

Difficulty of lighting

Expulsion of fumes

Heating inadequate, the fire ignites with difficulty given normal regulation

Fume exhaustion flue fire

Poor heating with a bright fire

Excessive heating and speed of combustion

Repulsion of fumes by the glass

- humid, or excessively large pieces of fuel- cold fume extraction flue

- insufficient draught

insufficient draught- influence of wind - flue is poorly insulated- flue is too short- flue is not properly sealed- flue section too small - flue partly blocked by a foreign body or by tar- presence of too powerful a V.M.C or of a kitchen extraction hood- during the opening of the door

- insufficient draught- excessively humid wood - logs diameter is excessive

- insufficient draught- excessively humid wood- negligent sweeping

- device and connections are inadequately sealed - excessive draught

- device overloaded with fuel- small pieces of fuel

- excessive draught

- inadequate draught condi-tions in nominal functioning of the device

- use small pieces of dry wood to form a hot bed of fuel- heat the flue by setting fire to newsprint with the door closed- verify the conditions of functioning of the flue and the level of air input into the dwelling.- Test of chimney pulling by means of a «vacuum gange»- consult the installer- Test of chimney pulling by means of a «vacuum gange»

- inspect the flue and if necessary, sweep out

- review the level of air input into the dwelling (verification by opening a door or a window)- open the air inlet before opening the door- always open the door slowly, in order to avoid any aspiration of fumes towards the outside of the fireplace - see above - use wood containing 15 to 20 % humidity- ensure adequately rapid combustion before loading the device with large pieces of fuel. Increase the level of primary air input.

- see above

- observe the normal frequency of sweeping.

- verify that the device is adequately sealed(joints)

- reduce the conditions of draught of the flue and in particular fit a draught cut-off set at between 10 et 20 Pa- close the baffle.- load the device with reasonable amounts of fuel (5 kg)- increase the diameter of the logs,- remove ash from the device less frequently- see above

- open the air inlet slightly in order to maintain the minimum value of output of the air of functioning- pay attention to the use of the kitchen hood- verify the position of the baffle

Page 9: NOTICE OF ASSEMBLY, UTILISATION AND MAINTE- NANCE ...€¦ · For your safety and satisfaction, entrust your installation to your installer/salesman. Nevertheless, ... - Assemble

9

PROBLEM FOUND POSSIBLE CAUSES REMEDIES

The glass becomes soiled very rapidly.

Formation of bistre (tar) in the fume extraction flue and in the device

- humid wood

- slightly insufficient draught

- reduced and excessively lengthy combustion

- humid wood- excessively long flue

- flue is poorly insulated

- combustion is too slow- lack of air input into the dwelling

- use wood with 15 to 20 % humidity- increase the level of air input into the device

- increase the section of the passage of fumes by slightly opening the air inlet- verify the position of the baffle

- avoid reduced combustion

- use wood with 15 to 20 % humidity- if possible, reduce the run of the fumes and introduce a tube into the flue- introduce heat insulation on the flue (mineral wool)- daily use of the device is advisable- verify the level of air input into the dwelling(opening of a door or of a window)- control the use of a kitchen hood

NOTE: The functioning of the fireplace insert depends a great deal on climatic and atmospheric conditions. Strong winds: excessive draught or expulsion Mist: lack of draught