notice of discontinued, some components for the skr/kr · sep. 1st 2012 messrs thk co., ltd....
TRANSCRIPT
Sep. 1st 2012
Messrs
THK CO., LTD.
Director, Senior General Manager of the Sales
Junji Shimomaki
Notice of discontinued, some components for the SKR/KR
Dear Sir, I would rejoice more and more on your stage of your health and prosperity. We
bestowed the exceptional patronage always, thank you very much.
By the way, our company so far, we have sent off to the world many new products, while starting
with linear systems make it better, continuing develop and model change of various products.
This occasion, we will stop the production of some components of SKR/KR. So, we have
replacement products were prepared.
We inform you in more detail of stop the production below.
The future, we will do our best to provide better products. Thank you for your cooperation and
understanding overlaid
Best regards
Symbol
《Production stoppage parts》
The housing A and middle flange for SKR/KR
Please see the attachment “technical data” for details.
《General order stop date》
March 29th 2013 (Orders will be received by the due this date)
In addition, if you have any questions, please contact our sales staff.
20/10/2012
Messrs
THK CO.,LTD.
The IMT division
Technical date With respect to discontinuation and replacement of component part for SKR/KR
1. Target components
Target components are as follows
Mode l No.Ball s c re w
le adBloc ktype
LM raille ngth
Ac c urac ygrade
With/ withouta motor
Withouta c ove r
Se ns ors pe c ific ation
Motorbrac ke t type
SKR33 10 A + 400 - P H - 1 B 0H
Intermediate flange Housing A
2.Detail by model number
【KR15】
(1) Motor interface part number, old to new conversion chart
Direct MountRated output Motor Size Old New
SGMM-A1 10W 0B ANSGMM-A2 20W 0B ANHC‐AQ013 10W 0A AMHC‐AQ023 20W 0A AM
□28 0D AS5phase CSK Ⅱ □28 0D AS
Motor type
ASC3*
Σ-miniAC servo
motor
□25
MitubishiElectricOrientalMotor
αStepCSK52*
YaskawaElectric
□28J2-Jr
(2) Housing A No dimensional changes, part number changes: 0 →A)
(3) Intermediate flange No dimensional changes, part number changes: See above chart
Intermediate flangeHousing A
【KR20/SKR20】
(1) Motor interface part number, old to new conversion chart. Direct Mount
Rated output Motor Size Old NewSGMM-A1 10W 3N ANSGMM-A2 20W 3N ANSGMM-A3 30W 3N ANSGMJV-A5 0B AQSGMAV-A5 0B AQHC‐AQ013 10W 3M AMHC‐AQ023 20W 3M AMHC‐AQ033 30W 3M AMHF‐MP053 0B AQHF‐KP053 0B AQ
Panasonic Crop. MSMD5A 50W □38 0A APQ1AA04003D 30W 0B AQQ1AA04005D 50W 0B AQ
Omron R88M‐K05030 50W □40 0B AQFanuc βis0.2/5000 50W □40 0B AQ
Keyence Corporation MV‐M05 50W □40 0B AQ□28 0F AS□42 0E AR□28 0F AS□42 0E AR
RK □42 0E ARUMK □42 0E ARCSK □42 0E ARCSK24*
Steppingmotor
2phase
αStep
CSK Ⅱ5phase
Motor type
MitubishiElectric
AC servomotor
SANYO ElectricSANMOTION
Q1
Σ-mini
Σ-Ⅴ
J3
MV
OMNUC G5
□25
□40
□40
UMK24*
CSK52*AS 46、ASC46、AR46ASC3*
β is series
Oriental Motor
YaskawaElectric
□40
□28
50W
MINAS A4
50W
J2-Jr
CSK54*RK54*
(2) Housing A change (Pat Number : 0 ⇒ A
<Discontinued lines> <replacement parts>
Intermediate flangeHousing A
(3) Intermediate flange **M,N type dose not change
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
【KR26/SKR26】
(1) Motor interface part number, old to new conversion chart. Direct Mount
Rated output Motor Size Old NewSGMM-A1 10W 0N ANSGMM-A2 20W 0N ANSGMM-A3 30W 0N ANSGMJV-A5 0B AQSGMAV-A5 0B AQHC‐AQ013 10W 0M AMHC‐AQ023 20W 0M AMHC‐AQ033 30W 0M AMHF‐MP053 0B AQHF‐KP053 0B AQ
Panasonic Crop. MSMD5A 50W □38 0A APQ1AA04003D 30W 0B AQQ1AA04005D 50W 0B AQ
Omron R88M‐K05030 50W □40 0B AQFanuc βis0.2/5000 50W □40 0B AQ
Keyence Corporation MV‐M05 50W □40 0B AQ□28 0F AS□42 0E AR□28 0F AS□42 0E AR
RK □42 0E ARUMK □42 0E ARCSK □42 0E AR
OMNUC G5
CSK54*RK54*
β is seriesMV
YaskawaElectric
□40
□28
50W
MINAS A4
50W
J2-Jr
□25
□40
□40
Oriental Motor
Motor type
MitubishiElectric
AC servomotor
SANYO ElectricSANMOTION
Q1
Σ-mini
Σ-Ⅴ
J3
Steppingmotor
2phase
αStep
CSK Ⅱ5phase
UMK24*
CSK52*AS 46、ASC46、AR46ASC3*
CSK24*
(2) Housing A No dimensional change (part number changes: 0 ⇒ A)
Intermediate flangeHousing A
(3) Intermediate flange **M,N type dose not change
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
【KR30H】
(1) Motor interface part number, old to new conversion chart. Direct Mount
Rated output Motor Size Old NewSGMJV-A5 0B AQSGMAV-A5 0B AQSGMJV-01 0B AQSGMAV-01 0B AQHF‐MP053 0B AQHF‐KP053 0B AQHF‐MP13 0B AQHF‐KP13 0B AQMSMD5A 50W 0A APMSMD01 100W 0A APQ1AA04003D 30W 0B AQQ1AA04005D 50W 0B AQQ1AA04010D 100W 0B AQR88M‐K05030 50W 0B AQR88M‐K10030 100W 0B AQβis0.2/5000 50W 0B AQβis0.3/5000 100W 0B AQMV‐M05 50W 0B AQMV‐M10 100W 0B AQ
□42 1C AR□60 0E AU□42 1C AR□60 0E AU□42 1C AR□60 0E AU□42 1C AR
□56.4 0D AT□42 1C AR
□56.4 0D AT
50W
100W
CSK56*RK54*
SANYO Electric
Motor type
AC servomotor
YaskawaElectric
OmronOMNUC
G5
SANMOTIONQ1
Keyence Corporation
β is seriesFanuc
□40
□40
Panasonic Crop.
100W
50WMitubishiElectric
J3
MINAS A4
Σ-Ⅴ
□38
Steppingmotor
Oriental Motor
UMK2phase
CSK
αStep
CSK Ⅱ
RK5phase
MV
CSK26*
AS 46、ASC46、AR46AS 6*、ASC66、AR6*
RK56*UMK24*UMK26*CSK24*
□40
□40
□40
CSK54*
□40
(2) Housing A No dimensional change.
Cover mounting tap is added for no-cover unit as well
Part number changed: 0 ⇒ A
Intermediate flange Housing A
(3) Intermediate flange changed from black oxide finish to THK AP-C Coating.(Refer to Clause2 ②-3
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
【KR33】
(1) Motor interface part number, old to new conversion chart.
Direct MountRated output Motor Size Old New
SGMJV-A5 5H AQSGMAV-A5 5H AQSGMJV-01 5H AQSGMAV-01 5H AQHF‐MP053 5H AQHF‐KP053 5H AQHF‐MP13 5H AQHF‐KP13 5H AQMSMD5A 50W 5K APMSMD01 100W 5K APQ1AA04003D 30W 5H AQQ1AA04005D 50W 5H AQQ1AA04010D 100W 5H AQR88M‐K05030 50W 5H AQR88M‐K10030 100W 5H AQβis0.2/5000 50W 5H AQβis0.3/5000 100W 5H AQMV‐M05 50W 5H AQMV‐M10 100W 5H AQ
□42 5I AR□60 5G AU□42 5I AR□60 5G AU□42 5I AR□60 5G AU□42 5I AR
□56.4 5F AT□42 5I AR
□56.4 5F AT
□38
AS 46、ASC46、AR46AS 6*、ASC66、AR6*
RK56*
□40
□40
□40
CSK54*
□40
MV
OmronOMNUC
G5
CSK26*
Steppingmotor
Oriental Motor
UMK2phase
CSK
αStep
CSK Ⅱ
RK5phase
100W
AC servomotor
□40
□40
Panasonic Crop.
50WMitubishiElectric
Keyence Corporation
β is seriesFanuc
MINAS A4
Σ-Ⅴ
SANYO ElectricSANMOTION
Q1
Motor type
UMK24*UMK26*CSK24*
50W
100W
CSK56*RK54*
YaskawaElectric
J3
(2) Housing A(Part Number Change: 0 ⇒ A)
<Discontinued lines> <replacement parts>
Intermediate flangeHousing A
(3) Intermediate flange changed from black oxide finish to THK AP-C Coating.(Refer to Clause2 ②-3
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
【SKR33】
(1) Motor interface part number, old to new conversion chart. Direct Mount
Rated output Motor Size Old NewSGMJV-A5 0H AQSGMAV-A5 0H AQSGMJV-01 0H AQSGMAV-01 0H AQHF‐MP053 0H AQHF‐KP053 0H AQHF‐MP13 0H AQHF‐KP13 0H AQMSMD5A 50W 0K APMSMD01 100W 0K APQ1AA04003D 30W 0H AQQ1AA04005D 50W 0H AQQ1AA04010D 100W 0H AQR88M‐K05030 50W 0H AQR88M‐K10030 100W 0H AQβis0.2/5000 50W 0H AQβis0.3/5000 100W 0H AQMV‐M05 50W 0H AQMV‐M10 100W 0H AQ
□42 0I AR□60 0G AU□42 0I AR□60 0G AU□42 0I AR□60 0G AU□42 0I AR
□56.4 0F AT□42 0I AR
□56.4 0F AT
Motor type
UMK24*UMK26*CSK24*
50W
100W
CSK56*RK54*
YaskawaElectric
J3
MINAS A4
Σ-Ⅴ
SANYO ElectricSANMOTION
Q1
100W
AC servomotor
□40
□40
Panasonic Crop.
50WMitubishiElectric
Keyence Corporation
β is series □40
Steppingmotor
Oriental Motor
UMK2phase
CSK
αStep
CSK Ⅱ
RK5phase
Fanuc
MV
OmronOMNUC
G5
CSK26*
□38
AS 46、ASC46、AR46AS 6*、ASC66、AR6*
RK56*
□40
□40
□40
CSK54*
(2) Housing A No dimensional change.
Cover mounting tap is added for no-cover unit as well
Part number changed: 0 ⇒ A
Intermediate flangeHousing A
(3) Intermediate flange changed from black oxide finish to THK AP-C Coating.(Refer to Clause2 ②-3
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
【KR45H】
(1) Motor interface part number, old to new conversion chart.
Direct MountRated output Motor Size Old New
SGMJV-A5 50W 0B AQSGMJV-01 100W 0B AQSGMJV-02 200W 0D A0SGMJV-04 400W 0D A0HF‐KP053 50W 0B AQHF‐KP13 100W 0B AQHF‐KP23 200W 0D A0HF‐KP43 400W 0D A0MSMD5A 50W 0A APMSMD01 100W 0A APMSMD02 200W 0C AYMSMD04 400W 0C AYQ1AA04005D 50W 0B AQQ1AA04010D 100W 0B AQQ1AA06020D 200W 0D A0Q1AA06040D 400W 0D A0R88M‐K05030 50W 0B AQR88M‐K10030 100W 0B AQR88M‐K20030 200W 0C AYR88M‐K40030 400W 0C AYβis0.2/5000 50W 0B AQβis0.3/5000 100W 0B AQβis0.4/5000 130W 0D A0βis0.5/6000 350W 0D A0βis1/6000 500W 0D A0MV‐M05 50W 0B AQMV‐M10 100W 0B AQMV‐M20 200W 0D A0MV‐M40 400W 0D A0
□60 0F AUCSK Ⅱ □60 0F AU
RK □60 0F AU
SANYO ElectricSANMOTION
Q1
Fanuc
Σ-Ⅴ
□60
□40
□40
□60
□38
□60Panasonic Crop.
Omron
Steppingmotor
Oriental MotorαStep
MINAS A4
5phase
MV
AS 6*、ASC66、AR6*
□40
□60
□40
□60
□40
□60
□40
□60
AC servomotor
Motor type
CSK56*RK56*
MitubishiElectric
J3
OMNUCG5
Keyence Corporation
β is series
YaskawaElectric
(2) Housing A No dimensional change.
Cover mounting tap is added for no-cover unit as well
Part number changed: 0 ⇒ A
Intermediate flangeHousing A
(3) Intermediate flange changed from black oxide finish to THK AP-C Coating.(Refer to Clause2 ②-3
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
【KR46】
(1) Motor interface part number, old to new conversion chart.
Direct MountRated output Motor Size Old New
SGMJV-A5 50W 0F 0QSGMJV-01 100W 0F AQSGMJV-02 200W 40 40SGMJV-04 400W 40 40HF‐KP053 50W 0F AQHF‐KP13 100W 0F AQHF‐KP23 200W 40 40HF‐KP43 400W 40 40MSMD5A 50W 0G APMSMD01 100W 0G APMSMD02 200W 30 30MSMD04 400W 30 30Q1AA04005D 50W 0F AQQ1AA04010D 100W 0F AQQ1AA06020D 200W 40 40Q1AA06040D 400W 40 40R88M‐K05030 50W 0F AQR88M‐K10030 100W 0F AQR88M‐K20030 200W 30 30R88M‐K40030 400W 30 30βis0.2/5000 50W 0F AQβis0.3/5000 100W 0F AQβis0.4/5000 130W 40 40βis0.5/6000 350W 40 40βis1/6000 500W 40 40MV‐M05 50W 0F AQMV‐M10 100W 0F AQMV‐M20 200W 40 40MV‐M40 400W 40 40
□60 10 10CSK Ⅱ □60 10 10
RK □60 10 10
AC servomotor
Motor type
CSK56*RK56*
MitubishiElectric
J3
OMNUCG5
Keyence Corporation
β is series
YaskawaElectric
□40
□60
□40
□60
□40
□60
□40
□60
MINAS A4
5phase
MV
AS 6*、ASC66、AR6*Steppingmotor
Oriental MotorαStep
Σ-Ⅴ
□60
□40
□40
□60
□38
□60Panasonic Crop.
Omron
SANYO ElectricSANMOTION
Q1
Fanuc
(2) Housing A ※No change --- 【1】,【3】,【4】.
※Cover mounting tap is added for no-cover unit as well
※Part number changed: 0 ⇒ A
<Discontinued lines> <replacement parts>
Intermediate flangeHousing A
(3) Intermediate flange changed from black oxide finish to THK AP-C Coating.(Refer to Clause2 ②-3
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
【SKR46】
(1) Motor interface part number, old to new conversion chart.
Direct MountRated output Motor Size Old New
SGMJV-A5 50W 0F AQSGMJV-01 100W 0F AQSGMJV-02 200W 04 AVSGMJV-04 400W 04 AVHF‐KP053 50W 0F AQHF‐KP13 100W 0F AQHF‐KP23 200W 04 AVHF‐KP43 400W 04 AVMSMD5A 50W 0G APMSMD01 100W 0G APMSMD02 200W 03 AYMSMD04 400W 03 AYQ1AA04005D 50W 0F AQQ1AA04010D 100W 0F AQQ1AA06020D 200W 04 AVQ1AA06040D 400W 04 AVR88M‐K05030 50W 0F AQR88M‐K10030 100W 0F AQR88M‐K20030 200W 03 AYR88M‐K40030 400W 03 AYβis0.2/5000 50W 0F AQβis0.3/5000 100W 0F AQβis0.4/5000 130W 04 AVβis0.5/6000 350W 04 AVβis1/6000 500W 04 AVMV‐M05 50W 0F AQMV‐M10 100W 0F AQMV‐M20 200W 04 AVMV‐M40 400W 04 AV
□60 01 AUCSK Ⅱ □60 01 AU
RK □60 01 AU
AC servomotor
Motor type
CSK56*RK56*
MitubishiElectric
J3
OMNUCG5
Keyence Corporation
β is series
YaskawaElectric
□40
□60
□40
□60
□40
□60
□40
□60
MINAS A4
5phase
MV
AS 6*、ASC66、AR6*Steppingmotor
Oriental MotorαStep
Σ-Ⅴ
□60
□40
□40
□60
□38
□60Panasonic Crop.
Omron
SANYO ElectricSANMOTION
Q1
Fanuc
(2) Housing A No dimensional change.
Cover mounting tap is added for no-cover unit as well
Part number changed: 0 ⇒ A
<Discontinued lines> <replacement parts>
Intermediate flangeHousing A
(3) Intermediate flange
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
<Discontinued lines> <replacement parts>
【KR55】
(1) Motor interface part number, old to new conversion chart. Direct Mount
Rated output Motor Size Old NewSGMJV-02 200W 00 A0SGMJV-04 400W 00 A0SGMJV-08 750W □80 0B AZHF‐KP23 200W 00 A0HF‐KP43 400W 00 A0HF‐KP73 750W □80 0B AZMSMD08 0A A5MAMA08 0A A5Q1AA06020D 200W 00 A0Q1AA06040D 400W 00 A0Q1AA07075D 750W □76 0A A5
Omron R88M‐K75030 750W □80 0A A5βis0.4/5000 130W 00 A0βis0.5/6000 350W 00 A0βis1/6000 500W 00 A0MV‐M20 200W 00 A0MV‐M40 400W 00 A0MV‐M75 750W □76 0A A5
□85 0G A6CSK Ⅱ □85 0G A6
RK □85 0G A6
AC servomotor
β is series
YaskawaElectric
Σ-Ⅴ
MINAS A4
AS 9*
J3
SANMOTIONQ1
CSK59*RK59*
Oriental MotorαStep
Motor type
□60
Steppingmotor 5phase
MV
OMNUC G5
Keyence Corporation
□60
MitubishiElectric
750WPanasonic Crop.
SANYO Electric
Fanuc
□80
□60
□60
□60
(2) Housing A No dimensional change.
(3) Intermediate flange 【B】type flange will be replaced with 【Z】type flange with dimensional change
shown below. Others will not change dimensionally; only part number will be
changed.
※changed from black oxide finish to THK AP-C Coating.
(Refer to Clause2 ②-3.)
<Discontinued lines> <replacement parts>
Intermediate flangeHousing A
【KR65】
(1) Motor interface part number, old to new conversion chart. Direct Mount
Rated output Motor Size Old NewSGMJV-02 200W 0A AVSGMJV-04 400W 0A AVSGMJV-08 750W □80 0G AZHF‐KP23 200W 0A AVHF‐KP43 400W 0A AVHF‐KP73 750W □80 0G AZMSMD08 2B A5MAMA08 2B A5Q1AA06020D 200W 0A AVQ1AA06040D 400W 0A AVQ1AA07075D 750W □76 2B A5
Omron R88M‐K75030 750W □80 2B A5βis0.4/5000 130W 0A AVβis0.5/6000 350W 0A AVβis1/6000 500W 0A AVMV‐M20 200W 0A AVMV‐M40 400W 0A AVMV‐M75 750W □76 2B A5
□85 2F A6CSK Ⅱ □85 2F A6
RK □85 2F A6
□80
□60
□60
□60
□60
MitubishiElectric
750WPanasonic Crop.
SANYO Electric
Fanuc
Motor type
□60
Steppingmotor 5phase
MV
OMNUC G5
Keyence Corporation
CSK59*RK59*
Oriental MotorαStep
AC servomotor
β is series
YaskawaElectric
Σ-Ⅴ
MINAS A4
AS 9*
J3
SANMOTIONQ1
(2) Housing A(Part Number Change: 0 ⇒ A)
<Discontinued lines> <replacement parts>
(3) Intermediate flange No dimensional change, only part number to be changed.
Changed from black oxide finish to THK AP-C Coating.(Refer to Clause2 ②-3
Intermediate flangeHousing A