notice of discontinued, some components for the skr/kr · sep. 1st 2012 messrs thk co., ltd....

26
Sep. 1 st 2012 Messrs THK CO., LTD. Director, Senior General Manager of the Sales Junji Shimomaki Notice of discontinued, some components for the SKR/KR Dear Sir, I would rejoice more and more on your stage of your health and prosperity. We bestowed the exceptional patronage always, thank you very much. By the way, our company so far, we have sent off to the world many new products, while starting with linear systems make it better, continuing develop and model change of various products. This occasion, we will stop the production of some components of SKR/KR. So, we have replacement products were prepared. We inform you in more detail of stop the production below. The future, we will do our best to provide better products. Thank you for your cooperation and understanding overlaid Best regards Symbol Production stoppage partsThe housing A and middle flange for SKR/KR Please see the attachment “technical data” for details. General order stop dateMarch 29 th 2013 (Orders will be received by the due this date) In addition, if you have any questions, please contact our sales staff.

Upload: trantram

Post on 25-Jun-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Sep. 1st 2012

Messrs

THK CO., LTD.

Director, Senior General Manager of the Sales

Junji Shimomaki

Notice of discontinued, some components for the SKR/KR

Dear Sir, I would rejoice more and more on your stage of your health and prosperity. We

bestowed the exceptional patronage always, thank you very much.

By the way, our company so far, we have sent off to the world many new products, while starting

with linear systems make it better, continuing develop and model change of various products.

This occasion, we will stop the production of some components of SKR/KR. So, we have

replacement products were prepared.

We inform you in more detail of stop the production below.

The future, we will do our best to provide better products. Thank you for your cooperation and

understanding overlaid

Best regards

Symbol

《Production stoppage parts》

The housing A and middle flange for SKR/KR

Please see the attachment “technical data” for details.

《General order stop date》

March 29th 2013 (Orders will be received by the due this date)

In addition, if you have any questions, please contact our sales staff.

20/10/2012

Messrs

THK CO.,LTD.

The IMT division

Technical date With respect to discontinuation and replacement of component part for SKR/KR

1. Target components

Target components are as follows

Mode l No.Ball s c re w

le adBloc ktype

LM raille ngth

Ac c urac ygrade

With/ withouta motor

Withouta c ove r

Se ns ors pe c ific ation

Motorbrac ke t type

SKR33 10 A + 400 - P H - 1 B 0H

Intermediate flange Housing A

2.Detail by model number

【KR15】

(1) Motor interface part number, old to new conversion chart

Direct MountRated output Motor Size Old New

SGMM-A1 10W 0B ANSGMM-A2 20W 0B ANHC‐AQ013 10W 0A AMHC‐AQ023 20W 0A AM

□28 0D AS5phase CSK Ⅱ □28 0D AS

Motor type

ASC3*

Σ-miniAC servo

motor

□25

MitubishiElectricOrientalMotor

αStepCSK52*

YaskawaElectric

□28J2-Jr

(2) Housing A No dimensional changes, part number changes: 0 →A)

(3) Intermediate flange No dimensional changes, part number changes: See above chart

Intermediate flangeHousing A

【KR20/SKR20】

(1) Motor interface part number, old to new conversion chart. Direct Mount

Rated output Motor Size Old NewSGMM-A1 10W 3N ANSGMM-A2 20W 3N ANSGMM-A3 30W 3N ANSGMJV-A5 0B AQSGMAV-A5 0B AQHC‐AQ013 10W 3M AMHC‐AQ023 20W 3M AMHC‐AQ033 30W 3M AMHF‐MP053 0B AQHF‐KP053 0B AQ

Panasonic Crop. MSMD5A 50W □38 0A APQ1AA04003D 30W 0B AQQ1AA04005D 50W 0B AQ

Omron R88M‐K05030 50W □40 0B AQFanuc βis0.2/5000 50W □40 0B AQ

Keyence Corporation MV‐M05 50W □40 0B AQ□28 0F AS□42 0E AR□28 0F AS□42 0E AR

RK □42 0E ARUMK □42 0E ARCSK □42 0E ARCSK24*

Steppingmotor

2phase

αStep

CSK Ⅱ5phase

Motor type

MitubishiElectric

AC servomotor

SANYO ElectricSANMOTION

Q1

Σ-mini

Σ-Ⅴ

J3

MV

OMNUC G5

□25

□40

□40

UMK24*

CSK52*AS 46、ASC46、AR46ASC3*

β is series

Oriental Motor

YaskawaElectric

□40

□28

50W

MINAS A4

50W

J2-Jr

CSK54*RK54*

(2) Housing A change (Pat Number : 0 ⇒ A

<Discontinued lines> <replacement parts>

Intermediate flangeHousing A

(3) Intermediate flange **M,N type dose not change

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

【KR26/SKR26】

(1) Motor interface part number, old to new conversion chart. Direct Mount

Rated output Motor Size Old NewSGMM-A1 10W 0N ANSGMM-A2 20W 0N ANSGMM-A3 30W 0N ANSGMJV-A5 0B AQSGMAV-A5 0B AQHC‐AQ013 10W 0M AMHC‐AQ023 20W 0M AMHC‐AQ033 30W 0M AMHF‐MP053 0B AQHF‐KP053 0B AQ

Panasonic Crop. MSMD5A 50W □38 0A APQ1AA04003D 30W 0B AQQ1AA04005D 50W 0B AQ

Omron R88M‐K05030 50W □40 0B AQFanuc βis0.2/5000 50W □40 0B AQ

Keyence Corporation MV‐M05 50W □40 0B AQ□28 0F AS□42 0E AR□28 0F AS□42 0E AR

RK □42 0E ARUMK □42 0E ARCSK □42 0E AR

OMNUC G5

CSK54*RK54*

β is seriesMV

YaskawaElectric

□40

□28

50W

MINAS A4

50W

J2-Jr

□25

□40

□40

Oriental Motor

Motor type

MitubishiElectric

AC servomotor

SANYO ElectricSANMOTION

Q1

Σ-mini

Σ-Ⅴ

J3

Steppingmotor

2phase

αStep

CSK Ⅱ5phase

UMK24*

CSK52*AS 46、ASC46、AR46ASC3*

CSK24*

(2) Housing A No dimensional change (part number changes: 0 ⇒ A)

Intermediate flangeHousing A

(3) Intermediate flange **M,N type dose not change

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

【KR30H】

(1) Motor interface part number, old to new conversion chart. Direct Mount

Rated output Motor Size Old NewSGMJV-A5 0B AQSGMAV-A5 0B AQSGMJV-01 0B AQSGMAV-01 0B AQHF‐MP053 0B AQHF‐KP053 0B AQHF‐MP13 0B AQHF‐KP13 0B AQMSMD5A 50W 0A APMSMD01 100W 0A APQ1AA04003D 30W 0B AQQ1AA04005D 50W 0B AQQ1AA04010D 100W 0B AQR88M‐K05030 50W 0B AQR88M‐K10030 100W 0B AQβis0.2/5000 50W 0B AQβis0.3/5000 100W 0B AQMV‐M05 50W 0B AQMV‐M10 100W 0B AQ

□42 1C AR□60 0E AU□42 1C AR□60 0E AU□42 1C AR□60 0E AU□42 1C AR

□56.4 0D AT□42 1C AR

□56.4 0D AT

50W

100W

CSK56*RK54*

SANYO Electric

Motor type

AC servomotor

YaskawaElectric

OmronOMNUC

G5

SANMOTIONQ1

Keyence Corporation

β is seriesFanuc

□40

□40

Panasonic Crop.

100W

50WMitubishiElectric

J3

MINAS A4

Σ-Ⅴ

□38

Steppingmotor

Oriental Motor

UMK2phase

CSK

αStep

CSK Ⅱ

RK5phase

MV

CSK26*

AS 46、ASC46、AR46AS 6*、ASC66、AR6*

RK56*UMK24*UMK26*CSK24*

□40

□40

□40

CSK54*

□40

(2) Housing A No dimensional change.

Cover mounting tap is added for no-cover unit as well

Part number changed: 0 ⇒ A

Intermediate flange Housing A

(3) Intermediate flange changed from black oxide finish to THK AP-C Coating.(Refer to Clause2 ②-3

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

【KR33】

(1) Motor interface part number, old to new conversion chart.

Direct MountRated output Motor Size Old New

SGMJV-A5 5H AQSGMAV-A5 5H AQSGMJV-01 5H AQSGMAV-01 5H AQHF‐MP053 5H AQHF‐KP053 5H AQHF‐MP13 5H AQHF‐KP13 5H AQMSMD5A 50W 5K APMSMD01 100W 5K APQ1AA04003D 30W 5H AQQ1AA04005D 50W 5H AQQ1AA04010D 100W 5H AQR88M‐K05030 50W 5H AQR88M‐K10030 100W 5H AQβis0.2/5000 50W 5H AQβis0.3/5000 100W 5H AQMV‐M05 50W 5H AQMV‐M10 100W 5H AQ

□42 5I AR□60 5G AU□42 5I AR□60 5G AU□42 5I AR□60 5G AU□42 5I AR

□56.4 5F AT□42 5I AR

□56.4 5F AT

□38

AS 46、ASC46、AR46AS 6*、ASC66、AR6*

RK56*

□40

□40

□40

CSK54*

□40

MV

OmronOMNUC

G5

CSK26*

Steppingmotor

Oriental Motor

UMK2phase

CSK

αStep

CSK Ⅱ

RK5phase

100W

AC servomotor

□40

□40

Panasonic Crop.

50WMitubishiElectric

Keyence Corporation

β is seriesFanuc

MINAS A4

Σ-Ⅴ

SANYO ElectricSANMOTION

Q1

Motor type

UMK24*UMK26*CSK24*

50W

100W

CSK56*RK54*

YaskawaElectric

J3

(2) Housing A(Part Number Change: 0 ⇒ A)

<Discontinued lines> <replacement parts>

Intermediate flangeHousing A

(3) Intermediate flange changed from black oxide finish to THK AP-C Coating.(Refer to Clause2 ②-3

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

【SKR33】

(1) Motor interface part number, old to new conversion chart. Direct Mount

Rated output Motor Size Old NewSGMJV-A5 0H AQSGMAV-A5 0H AQSGMJV-01 0H AQSGMAV-01 0H AQHF‐MP053 0H AQHF‐KP053 0H AQHF‐MP13 0H AQHF‐KP13 0H AQMSMD5A 50W 0K APMSMD01 100W 0K APQ1AA04003D 30W 0H AQQ1AA04005D 50W 0H AQQ1AA04010D 100W 0H AQR88M‐K05030 50W 0H AQR88M‐K10030 100W 0H AQβis0.2/5000 50W 0H AQβis0.3/5000 100W 0H AQMV‐M05 50W 0H AQMV‐M10 100W 0H AQ

□42 0I AR□60 0G AU□42 0I AR□60 0G AU□42 0I AR□60 0G AU□42 0I AR

□56.4 0F AT□42 0I AR

□56.4 0F AT

Motor type

UMK24*UMK26*CSK24*

50W

100W

CSK56*RK54*

YaskawaElectric

J3

MINAS A4

Σ-Ⅴ

SANYO ElectricSANMOTION

Q1

100W

AC servomotor

□40

□40

Panasonic Crop.

50WMitubishiElectric

Keyence Corporation

β is series □40

Steppingmotor

Oriental Motor

UMK2phase

CSK

αStep

CSK Ⅱ

RK5phase

Fanuc

MV

OmronOMNUC

G5

CSK26*

□38

AS 46、ASC46、AR46AS 6*、ASC66、AR6*

RK56*

□40

□40

□40

CSK54*

(2) Housing A No dimensional change.

Cover mounting tap is added for no-cover unit as well

Part number changed: 0 ⇒ A

Intermediate flangeHousing A

(3) Intermediate flange changed from black oxide finish to THK AP-C Coating.(Refer to Clause2 ②-3

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

【KR45H】

(1) Motor interface part number, old to new conversion chart.

Direct MountRated output Motor Size Old New

SGMJV-A5 50W 0B AQSGMJV-01 100W 0B AQSGMJV-02 200W 0D A0SGMJV-04 400W 0D A0HF‐KP053 50W 0B AQHF‐KP13 100W 0B AQHF‐KP23 200W 0D A0HF‐KP43 400W 0D A0MSMD5A 50W 0A APMSMD01 100W 0A APMSMD02 200W 0C AYMSMD04 400W 0C AYQ1AA04005D 50W 0B AQQ1AA04010D 100W 0B AQQ1AA06020D 200W 0D A0Q1AA06040D 400W 0D A0R88M‐K05030 50W 0B AQR88M‐K10030 100W 0B AQR88M‐K20030 200W 0C AYR88M‐K40030 400W 0C AYβis0.2/5000 50W 0B AQβis0.3/5000 100W 0B AQβis0.4/5000 130W 0D A0βis0.5/6000 350W 0D A0βis1/6000 500W 0D A0MV‐M05 50W 0B AQMV‐M10 100W 0B AQMV‐M20 200W 0D A0MV‐M40 400W 0D A0

□60 0F AUCSK Ⅱ □60 0F AU

RK □60 0F AU

SANYO ElectricSANMOTION

Q1

Fanuc

Σ-Ⅴ

□60

□40

□40

□60

□38

□60Panasonic Crop.

Omron

Steppingmotor

Oriental MotorαStep

MINAS A4

5phase

MV

AS 6*、ASC66、AR6*

□40

□60

□40

□60

□40

□60

□40

□60

AC servomotor

Motor type

CSK56*RK56*

MitubishiElectric

J3

OMNUCG5

Keyence Corporation

β is series

YaskawaElectric

(2) Housing A No dimensional change.

Cover mounting tap is added for no-cover unit as well

Part number changed: 0 ⇒ A

Intermediate flangeHousing A

(3) Intermediate flange changed from black oxide finish to THK AP-C Coating.(Refer to Clause2 ②-3

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

【KR46】

(1) Motor interface part number, old to new conversion chart.

Direct MountRated output Motor Size Old New

SGMJV-A5 50W 0F 0QSGMJV-01 100W 0F AQSGMJV-02 200W 40 40SGMJV-04 400W 40 40HF‐KP053 50W 0F AQHF‐KP13 100W 0F AQHF‐KP23 200W 40 40HF‐KP43 400W 40 40MSMD5A 50W 0G APMSMD01 100W 0G APMSMD02 200W 30 30MSMD04 400W 30 30Q1AA04005D 50W 0F AQQ1AA04010D 100W 0F AQQ1AA06020D 200W 40 40Q1AA06040D 400W 40 40R88M‐K05030 50W 0F AQR88M‐K10030 100W 0F AQR88M‐K20030 200W 30 30R88M‐K40030 400W 30 30βis0.2/5000 50W 0F AQβis0.3/5000 100W 0F AQβis0.4/5000 130W 40 40βis0.5/6000 350W 40 40βis1/6000 500W 40 40MV‐M05 50W 0F AQMV‐M10 100W 0F AQMV‐M20 200W 40 40MV‐M40 400W 40 40

□60 10 10CSK Ⅱ □60 10 10

RK □60 10 10

AC servomotor

Motor type

CSK56*RK56*

MitubishiElectric

J3

OMNUCG5

Keyence Corporation

β is series

YaskawaElectric

□40

□60

□40

□60

□40

□60

□40

□60

MINAS A4

5phase

MV

AS 6*、ASC66、AR6*Steppingmotor

Oriental MotorαStep

Σ-Ⅴ

□60

□40

□40

□60

□38

□60Panasonic Crop.

Omron

SANYO ElectricSANMOTION

Q1

Fanuc

(2) Housing A ※No change --- 【1】,【3】,【4】.

※Cover mounting tap is added for no-cover unit as well

※Part number changed: 0 ⇒ A

<Discontinued lines> <replacement parts>

Intermediate flangeHousing A

(3) Intermediate flange changed from black oxide finish to THK AP-C Coating.(Refer to Clause2 ②-3

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

【SKR46】

(1) Motor interface part number, old to new conversion chart.

Direct MountRated output Motor Size Old New

SGMJV-A5 50W 0F AQSGMJV-01 100W 0F AQSGMJV-02 200W 04 AVSGMJV-04 400W 04 AVHF‐KP053 50W 0F AQHF‐KP13 100W 0F AQHF‐KP23 200W 04 AVHF‐KP43 400W 04 AVMSMD5A 50W 0G APMSMD01 100W 0G APMSMD02 200W 03 AYMSMD04 400W 03 AYQ1AA04005D 50W 0F AQQ1AA04010D 100W 0F AQQ1AA06020D 200W 04 AVQ1AA06040D 400W 04 AVR88M‐K05030 50W 0F AQR88M‐K10030 100W 0F AQR88M‐K20030 200W 03 AYR88M‐K40030 400W 03 AYβis0.2/5000 50W 0F AQβis0.3/5000 100W 0F AQβis0.4/5000 130W 04 AVβis0.5/6000 350W 04 AVβis1/6000 500W 04 AVMV‐M05 50W 0F AQMV‐M10 100W 0F AQMV‐M20 200W 04 AVMV‐M40 400W 04 AV

□60 01 AUCSK Ⅱ □60 01 AU

RK □60 01 AU

AC servomotor

Motor type

CSK56*RK56*

MitubishiElectric

J3

OMNUCG5

Keyence Corporation

β is series

YaskawaElectric

□40

□60

□40

□60

□40

□60

□40

□60

MINAS A4

5phase

MV

AS 6*、ASC66、AR6*Steppingmotor

Oriental MotorαStep

Σ-Ⅴ

□60

□40

□40

□60

□38

□60Panasonic Crop.

Omron

SANYO ElectricSANMOTION

Q1

Fanuc

(2) Housing A No dimensional change.

Cover mounting tap is added for no-cover unit as well

Part number changed: 0 ⇒ A

<Discontinued lines> <replacement parts>

Intermediate flangeHousing A

(3) Intermediate flange

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

<Discontinued lines> <replacement parts>

【KR55】

(1) Motor interface part number, old to new conversion chart. Direct Mount

Rated output Motor Size Old NewSGMJV-02 200W 00 A0SGMJV-04 400W 00 A0SGMJV-08 750W □80 0B AZHF‐KP23 200W 00 A0HF‐KP43 400W 00 A0HF‐KP73 750W □80 0B AZMSMD08 0A A5MAMA08 0A A5Q1AA06020D 200W 00 A0Q1AA06040D 400W 00 A0Q1AA07075D 750W □76 0A A5

Omron R88M‐K75030 750W □80 0A A5βis0.4/5000 130W 00 A0βis0.5/6000 350W 00 A0βis1/6000 500W 00 A0MV‐M20 200W 00 A0MV‐M40 400W 00 A0MV‐M75 750W □76 0A A5

□85 0G A6CSK Ⅱ □85 0G A6

RK □85 0G A6

AC servomotor

β is series

YaskawaElectric

Σ-Ⅴ

MINAS A4

AS 9*

J3

SANMOTIONQ1

CSK59*RK59*

Oriental MotorαStep

Motor type

□60

Steppingmotor 5phase

MV

OMNUC G5

Keyence Corporation

□60

MitubishiElectric

750WPanasonic Crop.

SANYO Electric

Fanuc

□80

□60

□60

□60

(2) Housing A No dimensional change.

(3) Intermediate flange 【B】type flange will be replaced with 【Z】type flange with dimensional change

shown below. Others will not change dimensionally; only part number will be

changed.

※changed from black oxide finish to THK AP-C Coating.

(Refer to Clause2 ②-3.)

<Discontinued lines> <replacement parts>

Intermediate flangeHousing A

【KR65】

(1) Motor interface part number, old to new conversion chart. Direct Mount

Rated output Motor Size Old NewSGMJV-02 200W 0A AVSGMJV-04 400W 0A AVSGMJV-08 750W □80 0G AZHF‐KP23 200W 0A AVHF‐KP43 400W 0A AVHF‐KP73 750W □80 0G AZMSMD08 2B A5MAMA08 2B A5Q1AA06020D 200W 0A AVQ1AA06040D 400W 0A AVQ1AA07075D 750W □76 2B A5

Omron R88M‐K75030 750W □80 2B A5βis0.4/5000 130W 0A AVβis0.5/6000 350W 0A AVβis1/6000 500W 0A AVMV‐M20 200W 0A AVMV‐M40 400W 0A AVMV‐M75 750W □76 2B A5

□85 2F A6CSK Ⅱ □85 2F A6

RK □85 2F A6

□80

□60

□60

□60

□60

MitubishiElectric

750WPanasonic Crop.

SANYO Electric

Fanuc

Motor type

□60

Steppingmotor 5phase

MV

OMNUC G5

Keyence Corporation

CSK59*RK59*

Oriental MotorαStep

AC servomotor

β is series

YaskawaElectric

Σ-Ⅴ

MINAS A4

AS 9*

J3

SANMOTIONQ1

(2) Housing A(Part Number Change: 0 ⇒ A)

<Discontinued lines> <replacement parts>

(3) Intermediate flange No dimensional change, only part number to be changed.

Changed from black oxide finish to THK AP-C Coating.(Refer to Clause2 ②-3

Intermediate flangeHousing A