Page 1: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

Novasep Process: TangenX Tangential Flow Filtration Products 1

Strategies for Single Use Tangential Flow FiltrationIn Biopharmaceutical Applications

Michael LaBreckGlobal Product ManagerTangenX TFF Products

Page 2: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

2

SiusTM Single Use TFF Cassettes

Page 3: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

3

SiusTM family of single-use cassettes Purpose built for single-usePurpose built for single-use Ready to Use - Reduced prep time Delivered in 0.2M NaOH – Pre-sanitized

Cassette design for Development, Clinical, and Process Scale

SiusTM-LS 0.01 –0.1 m² surface area SiusTM 0.5 –2.5 m² surface area

SiusTM and SiusTM-LS Overview

Page 4: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

4

Contact Angle Measurement

(water at 20oC)

HyStream

Molecular Weight vs. % Rejection

0102030405060708090

100

0.1 1 10 100 1000 10000

Molecular Weight (kD)

% R

eje

cti

on

1K

3K

5K

10K

30K

50K

100K

300K

0.1um

Membrane Selectivity Curves for:

ProStream Membranes

HyStream Membranes

TangenX Membrane Properties

Modified Polyether Sulfone (mPES) membranes currently available ProStream:

• 1kD, 3kD, 5kD, 10kD, 30kD, 50kD, 100kD, 300kD• Neutrally Balanced Charge / Low Protein Binding

HyStream:• 5kD, 10kD, 30kD, 50kD, 100kD, 300kD, 0.1µm, 0.2µm, 0.45µm, 0.65µm• Hydrophilic - Minimal fouling with hydrophobic molecules / Low Protein Binding

Page 5: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

Novasep Process: TangenX Tangential Flow Filtration Products 5

Rejection Characteristics (UF Membranes)

1,000 10,000 100,000

Molecular Weight

0

100%

Per

cent

Rej

ectio

n

Page 6: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

Novasep Process: TangenX Tangential Flow Filtration Products 6

Rejection Characteristics (UF Membranes)

1,000 10,000 100,000

Molecular Weight

0

100%

Per

cent

Rej

ectio

n

Page 7: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

Novasep Process: TangenX Tangential Flow Filtration Products 7

Rejection Characteristics (UF Membranes)

1,000 10,000 100,000

Molecular Weight

0

100%

Per

cent

Rej

ectio

n

Page 8: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

Novasep Process: TangenX Tangential Flow Filtration Products 8

Pore Size Distribution (UF Membranes)

10KD

pore size distribution

Page 9: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

Novasep Process: TangenX Tangential Flow Filtration Products 9

Pore Size Distribution (UF Membranes)

Competitor pore size distribution TangenX pore size distribution

10kD 10kD

Page 10: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

Novasep Process: TangenX Tangential Flow Filtration Products 10

Flux vs TMP Monoclonal Antibody 1

30 mg/ml Formulation Buffer CF=70ml/min

404550556065707580859095

100

1 1.3 1.6 2 2.5

TMP (bar)

Flu

x (

LM

H) 1 GE

1 Pall

1 NS

1 ML

IBC Applications for BiopharmaceuticalsLa Jolla, CA June 1-3 2009

Page 11: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

11

LaborLabor

ConsumablesConsumables

WorkflowWorkflow

Single Use TFF Applications

Page 12: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

12

LaborLabor

ConsumablesConsumables

WorkflowWorkflow

Single Use TFF Applications

Page 13: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

13

Required Steps for TFF process

Set Up

Sanitize

Flush

NWP

Equilibrate

Process

Clean

Flush

NWP

Storage

RE-USABLE TFF

Time

Page 14: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

14

Required Steps for TFF process

Set Up

Sanitize

Flush

NWP

Equilibrate

Process

Clean

Flush

NWP

Storage

RE-USABLE TFF

Time

Process = 6 hrs

Page 15: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

15

Required Steps for TFF process

Set Up

Sanitize

Flush

NWP

Equilibrate

Process

Clean

Flush

NWP

Storage

RE-USABLE TFF

Time

Process = 6 hrs

Total Time = 12 hrs

Page 16: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

16

Process= 6 hrs

Time

Set Up

Equilibrate

Process

Required Steps for TFF process

SINGLE USE TFF

Page 17: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

17

Required Steps for TFF process

SINGLE USE TFF

Total Time = 7.0 hrs

Process= 6 hrs

Set Up

Equilibrate

Process

Page 18: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

18

Time Allocation Reusable TFF Process

Time Allocation Single Use TFF Process

A significant amount of time is spent preparing and cleaning reusable cassettes

Time is used more efficiently when using single-use cassettes

Water usage and utilities are conserved

Time Savings versus Single Use Cassettes

Page 19: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

19

Labor

Consumables

Workflow

Single Use TFF Applications

Page 20: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

20

Consumables Include:

Purified Water

Buffers

Cleaning Solutions

Filtration Cassettes

Developing a Model for Single Use TFF

Page 21: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

21

Economy of Single Use TFF

75% Less Buffer / WFI Required

230

60

0

50

100

150

200

250

Buffer/WFI Usage

(L/s

q. m

eter

)

Re-useSingle Use

Page 22: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

22

Consumables Include:

Purified Water

Buffers

Cleaning Solutions

Filtration Cassettes

Developing a Model for Single Use TFF

Page 23: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

23

Reusable Cassette Suppliers

Single Use – Economics

Average = $4,800 / meter2

$0

$500

$1,000

$1,500

$2,000

$2,500

$3,000

$3,500

$4,000

$4,500

1$ per sq meter surface area

Supplier A

Supplier B

Supplier C

Supplier D

Page 24: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

24

80% Less per TFF cassette

Other Supplier Reusable TFF$4,800 per meter2

Single Use – Economics

$4,800

$930

$0

$500

$1,000

$1,500

$2,000

$2,500

$3,000

$3,500

$4,000

$4,500

1$ per sq meter surface area

Re-useSingle use

TangenX SiusTM Single Use TFF$930 per meter2

Page 25: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

25

Membrane surface areas available 100 cm², 200 cm², 0.1 m²: Process development 0.5 m², 1.5 m², 2.5 m²: Pilot / Process

SiusTM-LS 0.01 –0.1 m² surface area SiusTM 0.5 –2.5 m² surface area

SiusTM and SiusTM-LS Overview

Page 26: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

26

NovaSetTM Reusable TFF Cassettes

Direct Scalability – From Single Use to ReusableSame channel geometry (ΔP and crossflow rate)

Same membrane chemistry (Prostream and Hystream)

Page 27: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

27

Labor

Consumables

Workflow

Single Use TFF Applications

Page 28: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

28

Reduces validation requirementsReduces validation requirements

Process flexibility Process flexibility

Reduces risk of cross-contaminationReduces risk of cross-contamination

Consistent membrane performance run to runConsistent membrane performance run to run

Removes process bottlenecks – Improves workflowRemoves process bottlenecks – Improves workflow

Other Benefits to Single Use TFF

Page 29: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

29

Pre-sanitized, 100% Integrity Tested

Equilibrate and ready-to-use

Reduce Labor by 50%

Reduce Buffer / WFI by 75%

Full range of formats and pore sizes

SiusTM and SiusTM-LS Summary

Page 30: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

30

SiusTM Cassette Holders & Disposable Flow Path Inserts

Page 31: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

31

Disposable Flow Path Inserts

Filter Plate Inserts Disposable Flowpath

Page 32: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

32

Filter Plate Inserts (TFP75-SE16)0.5 to 5.0 meter2

(up to 49 LPM)

Disposable

Pre-sanitized

USP Class VI Polypropylene

1” TC (4) ports

Low cost SS Holder

Disposable Flow Path Inserts

Page 33: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

33

TSPDI-VXBC: 10 m² up to 30 m² capacity

TFP99-SP20 Filter Plate Insert (150 LPM)

Disposable Flow Path Inserts

Page 34: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

34

Filter Plate Inserts – LS (TFPLS-SA08)0.01 m2 to 0.1 m2 x 5

Disposable

Pre-sanitized

USP Class VI Polypropylene

3/4” mini TC or luer lock

Low cost SS Holder

Disposable Flow Path Inserts

Page 35: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

Novasep Process: TangenX Tangential Flow Filtration Products 35

Single Use TFF:Case Study

Page 36: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

Novasep Process: TangenX Tangential Flow Filtration Products 36

Michael Xenelis, EMD Serono Biotech Center

IBC Bioprocess International Conference

October 16, 2009

Page 37: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

Novasep Process: TangenX Tangential Flow Filtration Products 37

Page 38: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

Novasep Process: TangenX Tangential Flow Filtration Products 38

Total Process Time = 13.1 Hours

Page 39: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

Novasep Process: TangenX Tangential Flow Filtration Products 39

Page 40: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

Novasep Process: TangenX Tangential Flow Filtration Products 40

Page 41: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

Novasep Process: TangenX Tangential Flow Filtration Products 41

Single Use TFF:Case Study

Page 42: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

42

Single Use TFF Case Study

Recombinant Protein

500L Batch Size

10X Concentration / 5 volume Diafiltration

Process Flux = 100 LMH

Process Time = 4 Hours

Membrane Area = 2.5 Sq. Meter

Single Use TFF vs. Reusable TFF

Page 43: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

43

Single Use TFF Case Study

Economic Model

20 runs per year

Membrane costs

Labor and Overhead (validation)

WFI and Buffers

Single Use TFF vs. Reusable TFF

Page 44: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

44

Single Use TFF Case Study

Membrane Costs

Run # vs. Cassette Cost / Run

$0

$1,000

$2,000

$3,000

$4,000

$5,000

$6,000

$7,000

$8,000

$9,000

$10,000

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Run Number

Cass

ette

Cost

per

Run

Re-Usable

Single Use

Page 45: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

45

Single Use TFF Case Study

Labor and Overhead

Labor

QA / QC

Validation

Facilities – HVAC, Clean Room

Page 46: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

46

Single Use TFF Case Study

Labor and Overhead

Labor and Overhead Rate $1,000/hr

hours $ hours $

Set-Up 0.5 $500 0.5 $500Sanitize 0.5 $500

Flush 0.5 $500NWP 0.5 $500

Equilibration 0.25 $250 0.3 $250Process 4.0 $4,000 4.0 $4,000Clean 2.5 $2,500 1.0 $1,000Flush 0.5 $500NWP 0.5 $500Store 0.5 $500

10.25 $10,250 5.75 $5,750

Reusable Single Use

$0

$2,000

$4,000

$6,000

$8,000

$10,000

$12,000Reusable vs. Single-Use Process Cost

1 2Process Type

Cost

(USD

)

Store

NWP

Flush

Clean

Process

Equili.

NWP

Flush

Sanitize

Set-Up

Page 47: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

47

Single Use TFF Case Study

Buffer Costs

WFI

Buffer chemicals

Consumables – filters, bags

Labor

QA/QC

Validation

Single Use TFF vs. Reusable TFF

Page 48: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

48

Single Use TFF Case Study

Buffer Costs

Buffer Cost $1.20 per literProcess Area 2.5 per m2Number of Runs 20 per campaign

Cost per run Total CostRe-Usable $690 $13,800Single Use $180 $3,600

Note: * Buffer cost includes system, maintainance, buffers, raw materials, monitoring, and disposal

Buffer Cost per Campaign

$13,800

$3,600

$0

$2,000

$4,000

$6,000

$8,000

$10,000

$12,000

$14,000

$16,000

Re-Usable

Single Use

Buffe

r Cos

t (U

SD)

Page 49: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

49

Single Use TFF Case Study: Summary

Total Cost per Campaign

$0

$50,000

$100,000

$150,000

$200,000

$250,000

1

Tota

l Cos

t

Re-UsableSingle Use

Cost / run Total Cost Cost / run Total CostOverhead & Labor $10,250 $205,000 Overhead & Labor $5,750 $115,000

Buffer Usage $690 $13,800 Buffer Usage $180 $3,600Consumables $500 $10,000 Consumables $2,000 $40,000

TOTAL COST $11,440 $228,800 $7,930 $158,600

Total Savings $70,200

Re-Usable Single Use

Page 50: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

50

Single Use TFF Case Study: Summary

45% Increase in Productivity

Process Time

10.25

5.75

0

2

4

6

8

10

12

Hou

rs

Reusable

Single Use

Page 51: Novasep Process: TangenX Tangential Flow Filtration Products 1 Strategies for Single Use Tangential Flow Filtration In Biopharmaceutical Applications Michael

5151

THANK YOU FOR YOUR ATTENTION