  • 8/12/2019 NOX Components Overview July 2011

    1/64

    NOX SYSTEMS AG P: +423 370 25 25Alvierweg 17 F: +423 370 25 26FL-9490 Vaduz www.noxsystems.comLiechtenstein

    NOXSecurity System

    ComponentsOverview

    (Detailed technical descriptions:see datasheets of the individual components)

    Distribution for: Europe ( NL, DK, N, S, F)

    NOX SYSTEMS AGAlvierweg 17FL-9490 VaduzLiechtenstein

    Phone +423 370 25 25Fax +423 370 25 [email protected]

    Scandinavia (DK, N, S, F)

    SHJ ElektronikHerningvej 258DK-9220 Aalborg st

    Denmark

    Phone +45 30 25 87 14Fax +45 98 15 87 [email protected]

    www.shjelektronik.dk

    Netherlands (NL)

    ARAS Security B.V.Thomas Edisonweg 5NL-5151 DH DrunenNetherlands

    Phone +31 416 32 00 42Fax +31 416 37 95 [email protected]

    FFIS approved class 3DANAK/DBI Security grade 3

    Registred inDenmark, Sweden, NorwayNetherlands Category 3Austria VS (P)

    EN 50130-4EN 50131-6

    mailto:[email protected]:[email protected]://www.noxsystems.com/http://www.noxsystems.com/mailto:[email protected]:[email protected]://www.shjelektronik.dk/http://www.shjelektronik.dk/mailto:[email protected]:[email protected]://www.aras.nl/http://www.aras.nl/http://www.aras.nl/mailto:[email protected]://www.shjelektronik.dk/mailto:[email protected]://www.noxsystems.com/mailto:[email protected]
  • 8/12/2019 NOX Components Overview July 2011

    2/64

    Page 2 / 64 Components Overview July 2011

  • 8/12/2019 NOX Components Overview July 2011

    3/64

    Components Overview July 2011 Page 3 / 64

    IndexNOX Control Units _____________________________________________________________ 5

    NOX SYS, NOX Control Unit ...................................................................................................... 5NOX Lite Sets, Small Control Units ............................................................................................. 6

    Control Units Spare Parts and Single Components __________________________________ 8

    Components for NOX SYS and NOX Lite ................................................................................... 8NOX PS5, Power Supply Unit 5A .............................................................................................. 11NOX PS5, Power Supply Unit 5A with Adapter Plate as Replacement for NOX PSU ................ 12NOX PS2, Power Supply Unit 2A .............................................................................................. 13NOX BOX, Control Unit Housing for NOX CPU / NOX PS5 ...................................................... 14NOX PS5, Power Supply Unit 5A integrated in NOX BOX Housing .......................................... 14NOX PS2, Power Supply Unit 2A integrated in NOX BOX Lite Housing .................................... 15

    NOX Control Panels __________________________________________________________ 16

    NOX CPA AP , Control Panel on wall ........................................................................................ 16NOX CPA UP ..., Control Panels in wall .................................................................................... 17

    NOX TPA Rev.C, Touch Panel 10.4 ........................................................................................ 18NOX PC User Interfaces Software ............................................................................................ 19Code Keypads .......................................................................................................................... 20

    NOX KPD , Code Keypads ............................................................................................... 20NOX UPE, Code Keypad in Feller Edizio Due Design .......................................................... 21

    NOX UPK, Key Switch in Feller Edizio Due Design ................................................................... 22

    NOX Bus, I/O Modules for Sensors / Actuators ____________________________________ 23

    NOX IO1, Single In-/Output Module .......................................................................................... 23NOX IO4 Rev.C, Quadruple In-/Output Module ......................................................................... 24NOX RE4, Quadruple Relay Module ......................................................................................... 25NOX O32, 32 Open Collector Output Module ............................................................................ 26

    NOX M31, Mini In-/Output Module ............................................................................................ 27NOX MIO Rev.B, Multi Input/Output Module ............................................................................. 28NOX UP4, In- / Outputmodule in Feller Edizio Due Design ....................................................... 29NOX IR1, NOX Bus I/O Module for Alarmcom IR270T Detector ................................................ 30

    NOX Bus Cardreader Interfaces _________________________________________________ 31

    NOX CRx, Cardreader Interface Modules ................................................................................. 31NOX CMx, Cardreader Interface Module with Offline Functions ................................................ 32

    NOX Bus Repeater / Converter and Communication Modules ________________________ 33

    NOX RPT, NOX Bus Repeater / Converter ............................................................................... 33NOX ATU, Serial Communication Interface with ATU Protocol ................................................. 34NOX ESP, Serial Interface with several Protocols ..................................................................... 35NOX Bus Extension via TCP/IP ................................................................................................ 36

    NOX MXA, Bus Extension via TCP/IP .................................................................................. 36NOX MXA mini, Mini Bus Extension via TCP/IP ................................................................... 37

    Interface Module for Third Party Systems ________________________________________ 38

    NOX IS9, Interface for SAEL S9 (SECULON) ........................................................................... 38NOX S8P RevC, Interface for SAEL S8 (PRISMA) ................................................................... 39NOX IFT, Interface to Thor Bus ................................................................................................. 40NOX ABI M-Bus, Interface to ABI Control Unit with M-Bus ........................................................ 41NOX RXP, Wireless Receiver for Paradox Detectors ................................................................ 42

    NOX Sensors ________________________________________________________________ 43

    NOX THS, Temperature and Humidity Sensor .......................................................................... 43NOX THT, Wireless Temperature and Humidity Sensor............................................................ 44NOX FLD, Water Detector ........................................................................................................ 45

  • 8/12/2019 NOX Components Overview July 2011

    4/64

    Page 4 / 64 Components Overview July 2011

    Wireless Components of NOX Picture Monitoring System (PMGS) ____________________ 46

    Wireless receiver modules ........................................................................................................ 46NOX RXM, Wireless Receiver Module with NOX Bus ........................................................... 46NOX RXR, Wireless Receiver Module with Relay ................................................................. 47NOX BPR, portable alerting receiver .................................................................................... 48

    Wireless transmitter modules .................................................................................................... 49

    NOX TXM, wireless picture detector ..................................................................................... 49NOX TXS, Wireless Picture Detector Mini ............................................................................ 50NOX TXK, Wireless Detector ................................................................................................ 51NOX TXT, Wireless Transmission Detector Mini .................................................................. 51NOX TXM REF, Radio Reference Transmitter ...................................................................... 52NOX THT, Wireless Temperature and Humidity Sensor ....................................................... 53

    Supplies / Accessories_________________________________________________________ 54

    Mounting Plate .......................................................................................................................... 54Empty Plate for 8 DASK Cases ............................................................................................ 54Mounting Plate with 8 DASK Cases and Cables ................................................................... 54Mounting Plate with 8 DASK Cases ...................................................................................... 55

    Empty Plate for 4 DASK Cases ............................................................................................ 55Mounting Plate with 4 DASK Cases and Cables ................................................................... 56NOX TNA, Empty Mounting Plate ......................................................................................... 56

    DASK Case ............................................................................................................................... 57PCBA Fixation for DASK Case .................................................................................................. 57Batteries.................................................................................................................................... 58Cables ...................................................................................................................................... 58

    Cable NOX Bus, 4th Dask Plate ........................................................................................... 58Cable NOX Bus, 8th Dask Plate ........................................................................................... 59NOX Bus Terminal................................................................................................................ 59USB Cable to CPU_V3 Motherboard .................................................................................... 60

    Spare Fuses for NOX Modules ................................................................................................. 61

    SMD Fuse Set 500mAT ........................................................................................................ 61SMD Fuse Set 1AT............................................................................................................... 61SMD Fuse Set 2AT............................................................................................................... 61SMD Fuse Set 3AT............................................................................................................... 61SMD Fuse Set 5AT............................................................................................................... 61

    NOX Software Components _____________________________________________________ 62

    NOX Config, PC Configuration Software for the NOX Security System ..................................... 62NOX PC Control Panel .............................................................................................................. 62NOX PC TPA Licence, PC Touch Panel Software Licence ....................................................... 63NOX SIMS, Security Information Managment System ............................................................... 63NOX Logger .............................................................................................................................. 63

    NOX Time ................................................................................................................................. 63NOX iNOX ................................................................................................................................ 64NOX iOS ................................................................................................................................... 64

  • 8/12/2019 NOX Components Overview July 2011

    5/64

    Components Overview July 2011 Page 5 / 64

    NOX Control Units

    NOX SYS, NOX Control Unit

    SpecificationBottom Housing Steel sheet galvanised, 2mm

    CoverSteel sheet, 2mm,powder coated RAL9006 (white aluminium)

    Dimensions (L x W x H) 605 x 410 x 124 mm

    Weight with Cover (without batteries) 15.9 kg

    Peak current from NOX PS5 5A

    Connections AC Input, Batteries, 3 x NOX Bus, 2 x 15VDC Output

    Tamper Monitoring Integrated, through tamper contactVibration Protection Integrated, vibration sensor on NOX MIO

    Space for alarm transmission system up to 150 x 200 x 95 mm

    Space for Batteriesup to 2 x 17 Ah, Valve Regulated Lead Acid batteries (VRLAtype)

    Scope of delivery

    N106, NOX BOX, Control Unit HousingN109, NOX PS5, Power Supply Unit 5AN166, NOX CPU V3, Central Processing Unit complete(with SW Licence NOX Full)N105, NOX MIO, Multi Input/Output Module (internal)

    Part. No. N101

    The Unit is delivered assembled and tested.

    The latest system software is installed.

  • 8/12/2019 NOX Components Overview July 2011

    6/64

  • 8/12/2019 NOX Components Overview July 2011

    7/64

    Components Overview July 2011 Page 7 / 64

    Licences from the NOX System softwareDescription Part. No.Licence NOX Lite -- (included in N171 and N177)

    Update NOX Lite -> NOX Advanced S101Update NOX Lite -> NOX Full S102Update NOX Advanced -> NOX Full S103(included in N101)

    SW Licence keyNOX Lite

    (Standard for NOXLite Sets)

    NOX Advanced NOX Full

    Max. number of users 50 100 unlimited (10000)

    Max. number of Areas 20 40 unlimited (800)

    Max. number ofTimeprofiles

    3 6 unlimited(400)

    NOX TIO (withoutIP/Telnet communication)

    yes yes yes

    NOX TIO complete no yes yes

    Alarm per email no yes Yes

    IP Bus (NPort) no yes yes

    Master/Slave only Slave only Slave Master and SlaveModbus Interface no no yes

    Smart Phone, Smart PadInterface(for iPhone/iPod/Android)

    no yes yes

    SIMS Server integration yes yes yes

  • 8/12/2019 NOX Components Overview July 2011

    8/64

    Page 8 / 64 Components Overview July 2011

    Control Units Spare Parts and SingleComponents

    Components for NOX SYS and NOX Lite

    Component Part No. Description

    CommonforNOXSYSandNOXLite

    N168NOX CPU V3, Motherboard(without Toradex CPU Module (DIMM))

    T528 Tamper contact with cable and plug

    T525Cable NOX Bus, to connect any modules(e.g. MIO)

    T530 Cable USB to CPU_V3 Motherboard

  • 8/12/2019 NOX Components Overview July 2011

    9/64

    Components Overview July 2011 Page 9 / 64

    ForNO

    XSYSonly

    N106

    NOX BOX, Control Unit Housing includes:

    Covers for the cable entries

    Holding bracket for 2x 17Ahbatteries (without batteries)

    T528, Tamper contact with cableand connector

    N166

    NOX CPU V3, CPU complete(with SW Licence NOX Full)consists of:

    N168, NOX CPU V3, Motherboardwith 3 bus connections

    N167, Toradex CPU Module(DIMM) with SW Licence NOX Full

    Replacement for NOX CPU V1 andNOX CPU V2

    N167

    Toradex CPU Module (DIMM) includes:

    Windows Embedded

    NOX System Software with SWLicence NOX Full

    T529 Cable, PS5 to the batteries

  • 8/12/2019 NOX Components Overview July 2011

    10/64

    Page 10 / 64 Components Overview July 2011

    N

    OXLite

    N173

    NOX BOX Lite, Control Unit Housing Liteincludes:

    T528, Tamper contact with cableand plug

    Replacement for SE06, NOX SE emty

    cabinet.

    N175

    NOX CPU V3 Lite, complete CPU(with SW Licence NOX Lite)contents:

    N168, NOX CPU V3, Motherboardwith 3 bus connections

    N174, Toradex CPU Module(DIMM) with SW Licence NOX Lite

    N174

    Toradex CPU Module (DIMM) includes:

    Windows Embedded

    NOX System Software with SWLicence NOX Lite

    T524 Cable, PS2 to the batteries

  • 8/12/2019 NOX Components Overview July 2011

    11/64

    Components Overview July 2011 Page 11 / 64

    NOX PS5, Power Supply Unit 5A

    SpecificationDimensions (L x W x H) 220 x 125 x 100 mm

    Weight 1.0 kg

    Input Voltage 100240 VAC; 50/60Hz (with active PFC)

    Output Voltage 15VDCMaximum Output Current 5A

    Batteries Charge Voltage 2630VDC (adjustable)

    Batteries Charge Current max. 2A

    Batteries Supported 2 x 7 Ah/12V to 2 x 42 Ah/12V

    ConnectionsAC Input, Batteries, Tamper contact, NOX Bus,2 x 15VDC Output

    Part. No. N109

    The Unit is delivered assembled and tested.

    Single component Part. No. Description

    N138 NOX PS5 Print 5A (PCBA)

    N139AD/DC Power Supply 32V/150W(with active PFC, overload and overtemperatureprotection)

    T522 Cable, PS5 Power Supply to Print (PCBA)

  • 8/12/2019 NOX Components Overview July 2011

    12/64

    Page 12 / 64 Components Overview July 2011

    NOX PS5, Power Supply Unit 5A with Adapter Plate asReplacement for NOX PSU

    When replacing the NOX PSU power supply unit, the NOX PS5 with the adapter plate fits into the

    older housing.

    SpecificationAdapter Plate Material Aluminium

    Dimensions (L x W x H) 340 x 125 x 95 mm

    Weight 1.2kg

    Part. No. N140All other specifications are identical with part no. N109.

    The Unit is delivered assembled and tested.

  • 8/12/2019 NOX Components Overview July 2011

    13/64

    Components Overview July 2011 Page 13 / 64

    NOX PS2, Power Supply Unit 2A

    Small low priced power supply unit with 2A continous output current.

    SpecificationDimensions (L x W x H) 180 x 125 x 80 mm

    Weight 0.64kg

    Input Voltage 100240 VAC; 50/60Hz

    Output Voltage 15 VDC

    Maximum Output Current2 A continuous4 A peak (without Batteries charging during this time)

    Battery Charge Voltage 2630VDC (adjustable)

    Batteriy Charge Current max. 2A

    Batteries Supported 2 x 7 Ah/12V bis 2 x 42 Ah/12V

    Part. No. N188

    The Unit is delivered with cable, without mounting parts.

    Component Part. No. Description

    N138 NOX PS5 Print (PCBA)

    N176AD/DC Power Supply 32V/75W(with overload and overtemperature protection)

    T523 Cable PS2, Power Supply to Print

  • 8/12/2019 NOX Components Overview July 2011

    14/64

    Page 14 / 64 Components Overview July 2011

    NOX BOX, Control Unit Housing for NOX CPU / NOXPS5

    SpecificationBottom Housing Steel sheet galvanised, 2mm

    CoverSteel sheet, 2mm,powder coated RAL9006 (white aluminium)

    Dimensions (L x W x H) 604 x 404 x 124 mm

    Weight with Cover (without batteries) 12.8 kg

    Scope of delivery- Covers for the cable entries (2 pcs.)- Holding bracket for 2 x 17Ah batteries (without batteries)- T528, Tamper contact with cable and plug

    Part. No. N106

    NOX PS5, Power Supply Unit 5A integrated in NOX BOXHousing

    SpecificationPart. No. N104

    All other specifications are identical with part no. N109 and N106.

    The unit is delivered assembled and tested with the housing.

  • 8/12/2019 NOX Components Overview July 2011

    15/64

    Components Overview July 2011 Page 15 / 64

    NOX PS2, Power Supply Unit 2A integrated in NOX BOXLite Housing

    SpecificationBottom Housing Steel sheet, galvanised, 2mm

    CoverSteel sheet, 2mm,powder coated RAL9006 (white aluminium)

    Dimensions (L x W x H) 510 x 320 x 105 mm

    Weight with Cover (without batteries) 6.70 kg

    Part. No. N189All other specifications are identical with part no. N188.

    The Unit is delivered assembled and tested with the Lite housing.

  • 8/12/2019 NOX Components Overview July 2011

    16/64

    Page 16 / 64 Components Overview July 2011

    NOX Control PanelsWith a control panel the NOX Security System can be controlled and monitored.

    NOX CPA AP , Control Panel on wall

    These control panels have a full graphic display with 128 x 64 Pixel with white backlight and anumeric pad with additional function keys.

    N110AP N146

    Specification (NOX CPA AP Aluminium)Case Aluminium anodized

    Display Full graphic LCD 128 x 64 pixels

    Backlight LED white

    Lexan Screen Light grey with numeric pad and function keys

    Tamper Monitoring Integrated (through tamper contact)

    Buzzer Integrated

    Connection to the Control Unit NOX Bus

    Dimensions (L x W x H) 175 x 110 x 23mm

    Mounting On wall

    Part. No. N110AP

    Specification (NOX CPA AP PVC)Case PVC greyDimensions (L x W x H) 177 x 112 x 29mm

    Part. No. N146All other specifications are identical with part no. N110AP.

  • 8/12/2019 NOX Components Overview July 2011

    17/64

    Components Overview July 2011 Page 17 / 64

    NOX CPA UP ..., Control Panels in wall

    These control panel cosists of a graphical display (128 x 64 Pixel) with white backlight and anumeric pad with function keys.

    N110UP N114

    Specification (NOX CPA UP Aluminium)Case Aluminium anodized

    Display Full graphic LCD 128 x 64 Pixel

    Backlight LED white

    Foilkeypad Light-grey with numeric pad and function keys

    Monitoring tamper Integrated (through tamper contact)Buzzer Integrated

    Connection to the Control Unit NOX Bus

    Dimensions (L x W x H) 212 x 148 x 23mm

    Mount In wall

    Part. No. N110UP

    Specification (NOX CPA UP Design)Case Aluminium anodized, without visible screws

    Dimensions (L x W x H) 212 x 148 x 23mm

    Mount In wall; Steel base plate with holding magnet

    Part. No. N114

    All other specifications are identical with part no. N110UP.

    NOX CPA UP Mounting SuppliesSupply Part. No. Description

    N110Box Wooden box for NOX CPA UP for in wall mount

  • 8/12/2019 NOX Components Overview July 2011

    18/64

    Page 18 / 64 Components Overview July 2011

    NOX TPA Rev.C, Touch Panel 10.4

    Additonally to the controlling and monitoring capabilities of the whole system, the 10.4 TouchPanel Rev.C offers as a highlight, the ability to arm and disarm areas directly on coloured floorplans.

    Specification (NOX TPA Rev.C)Front Steel, powder coated RAL9002 (grey white)

    Dimensions (L x W x H) 312 x 242 x 76 mm

    Input Voltage 100 -240 VAC (external AC Adapter)

    Connection to the Control Unit Ethernet (RJ45)

    Scope of delivery

    -Touch Panel PC with:

    10.4 SVGA TFT LCD

    Microsoft Windows XP Embedded with SP3

    Microsoft .NET 2.0 Framework

    128MB RAM, 128MB Flash Memory-TPALoader2 Software(loads NOXTPA2 application from the control unit)

    -External AC Adapter-Front frame-without mounting supplies (see below)

    Part. No. N111

    The mounting supply decides the type of mounting, in wall or on wall (with noble natural beechframe).

    NOX TPA mounting accessories (for any TPA Rev)

    Supply Part. No. Description

    N111Box Wooden box for NOX TPA for in wall mount

    N112In wall mount frame aluminium natureDimensions (L x W x H): 392 x 312 x 4 mm

  • 8/12/2019 NOX Components Overview July 2011

    19/64

    Components Overview July 2011 Page 19 / 64

    Supply Part. No. Description

    N118On wall mount natural beech frame, clearcoat finishOutside dimensions (L x W x H): 420 x 345 x 80 mm

    N113

    Complete on wall mount frame, consists of:- N112, In wall frame aluminium nature- N118, On wall frame in natural beech, clearcoat

    finish

    NOX PC User Interfaces Software

    Specification (NOX PC TPA Software licence)

    Basic Functions Identically with NOXTPA2 software (with floorplans),optimized for Touchcontrol; has to be configured as amodule

    LicenceFinal constumer licence for 1 Control Unit(can be installed on any number of PCs)

    Operating systems Microsoft Windows 2000, XP, Vista, 7 (32 and 64Bit)

    Part. No. S100

    Compatibility

    This licence runs with:

    PCTPALoader.exe (Application TPA V1.00 toV1.99e which runs on TPA Rev.A and TPA Rev.BHardware as well), not for new installations!

    PCTPA2Loader.exe (Application TPA V2.00 toactual Version which runs on TPA Rev.C Hardware

    as well)More informations at NOX Software Components.

    Specification (NOX PC User Panel Software)

    Basic Functions

    Allows complete control on user level with:- User Profiles- Time Profiles- Filter rules for Log entries- Runs without configuration

    Licence none

    Operating system Microsoft Windows 2000, XP, Vista, 7 (32 and 64Bit)

    Part. No. S401

    More informations at NOX Software Components.

  • 8/12/2019 NOX Components Overview July 2011

    20/64

    Page 20 / 64 Components Overview July 2011

    Code Keypads

    NOX KPD , Code KeypadsThe Code keypads consist of a numeric pad and two different coloured LEDs as status indicators.The Units are normally used to arm or disarm areas or to release a door opener.

    N113AP N113UP N116

    Specification (NOX KPD AP Aluminium)Case Aluminium anodized

    Foil Keypad Light-grey with numeric pad and function keys

    Display LED red and green (as status indicator)

    Tamper Monitoring Integrated, through tamper contact

    Buzzer Integrated

    Connection to the control unit NOX BusDimensions (L x W x H) 100 x 70 x 23mm

    Mount On wall

    Part. No. N113AP

    Specification (NOX KPD UP Aluminium)Dimensions (L x W x H) 136 x 106 x 23mm

    Mount In wall

    Part. No. N113UPAll other specifications are identical with part no. N113AP.

    Specification (NOX KPD UP Design)Case Aluminium anodized, no visible screwsDimensions (L x W x H) 136 x 106 x 23mm

    Mount In wall; Steel base plate with holding magnet

    Part. No. N116All other specifications are identical with part no. N113UP.

  • 8/12/2019 NOX Components Overview July 2011

    21/64

    Components Overview July 2011 Page 21 / 64

    NOX KPD UP MontagezubehrSupply Part. No. Description

    N113Box Wooden Box for NOX KPD UP, in wall mount

    NOX UPE, Code Keypad in Feller Edizio Due DesignThe code keypad consists of a numeric pad and two different coloured LEDs as status indicators.

    The Unit is normally used to arm and disarm areas or to release a door opener.The code keypad can be mounted with a conventional socket and combine with different coversas required from the Feller Edizio Due Design.

    N250

    SpecificationCase Feller Edizio Due Designframe, white

    Lexan Screen Light-grey with numeric pad and function keys

    Display LED red and green (as status indicator)

    Tamper Monitoring Integrated, through tamper contactBuzzer Integrated

    Connection to the control unit NOX Bus

    Dimensions (L x W x H)-incl. Feller Frame-only PCBA

    88 x 88 x 35 mm60 x 60 x 35 mm

    Mount In wall

    Part. No. N250Edizio Due Design line was specially designed for the Swiss Market and according to SwissStandards.

  • 8/12/2019 NOX Components Overview July 2011

    22/64

    Page 22 / 64 Components Overview July 2011

    NOX UPK, Key Switch in Feller Edizio Due Design

    Universal key switch with cylinder lock and 2 different coloured LEDs asstate indicator. The keyswitch is available in 2 versions, with or without state LEDs.

    Variante C218Specification (NOX UPK-xx)Case Feller Edizio Due Designframe, white

    Dimensions (L x W x H)(incl. Feller Frame)

    88 x 88 x 35 mm

    Typ of cylinder Kaba 8 with 2 keys (www.kaba.ch/en)

    Tamper Monitoring Integrated, through tamper contact

    ConnectionsPotential free contacts and driving LEDs (C218 only)with 15VDC (optional 5VDC)

    Versions of NOX UPK, Key-switchLabel Description Part No.NOX UPK-Z Key-switch, without LEDs, with Cylinder Kaba 8 C216NOX UPK-ZL Key-switch, with LEDs, with Cylinder Kaba 8 C218

    http://www.kaba.ch/enhttp://www.kaba.ch/enhttp://www.kaba.ch/enhttp://www.kaba.ch/en
  • 8/12/2019 NOX Components Overview July 2011

    23/64

    Components Overview July 2011 Page 23 / 64

    NOX Bus, I/O Modules for Sensors /Actuators

    NOX IO1, Single In-/Output Module

    The NOX IO1 module has one resistance controlled input and one free programmable relay. Themodule can be used for e.g. monitoring a door and for triggering the door opener at the sametime.

    Specification (NOX IO1)Case Plastic ABS, white (DASK Case)

    Tamper Monitoring Integrated, through tamper contact

    Dimensions (L x W x H) 85 x 66 x 27mm

    Connection to the control unit NOX Bus

    Input 1 resistance monitored Input

    Output1 potential-free Relay output(max. contact rating 30V/1A)

    Part. No. N117

  • 8/12/2019 NOX Components Overview July 2011

    24/64

    Page 24 / 64 Components Overview July 2011

    NOX IO4 Rev.C, Quadruple In-/Output Module

    The IO4 Rev.C Module has four resistance monitored inputs. As a unique feature the monitoredresistor value can be configured for each input individually in the range from 3 k up to 40 k.Thus different types of detectors can be connected or migrated from existing installation quitesimple. In addition individually input delay time is also possible.The module supports Tripple end of lineresistors. This allows covering alarm, tamperingmonitoring and anti mask detection on one inputting only.

    Additional the module has 4 open collector outputs.

    SpecificationCase Plastic ABS, white (DASK Case)

    Tamper Monitoring Integrated, through tamper contact

    Dimensions (L x W x H) 85 x 66 x 27 mm

    Connection to the Control Unit NOX Bus

    Inputs 4 resistance monitored Inputs

    Outputs4 Open Collector Outputs(max. output current 500mA for all 4 Outputs)

    Part. No. N119Replacement for NOX IN4, Inputmodule (Part. No. N120)

  • 8/12/2019 NOX Components Overview July 2011

    25/64

    Components Overview July 2011 Page 25 / 64

    NOX RE4, Quadruple Relay Module

    NOX RE4 is a universal output module with four free programmable relays.

    SpecificationCase Plastic ABS, white (DASK Case)

    Tamper Monitoring Integrated, through tamper contact

    Dimensions (L x W x H) 85 x 66 x 27 mm

    Connection to the control unit NOX Bus

    Inputs None

    Outputs 4 potential free Relay Outputs, each 30VDC@1A

    Part. No. N122

  • 8/12/2019 NOX Components Overview July 2011

    26/64

    Page 26 / 64 Components Overview July 2011

    NOX O32, 32 Open Collector Output Module

    This module suits well for applications which require many outputs at once. The outputs can beconnected either via screw terminal or through 0.1male header multipoint connector.The ports are configurable by a jumper as Open Collector, with 2VDC or with VBus (15VDC)potentia. The power supply for LEDs is variable in the range of 1.9 - 2.2. Volt.Every output can be programmed with the graphic NOX Formel Editor and can toggle with a freeprogrammable frequency. All of these features are combined in a compact PCBA form factor.

    SpecificationCase None (fits in MIO Case)

    Tamper MonitoringIntegrated, through tamper contact(only activ with MIO PVC Case)

    Dimensions (L x W x H) print (PCBA) 118 x 55 x 15 mm

    Connection to the control unit NOX Bus

    Input1 digital Input without resistance monitoring (open / closed,e.g. external contact)

    Outputs

    32 Open Collector Outputs(max. output current 300mA for each Output, max. 3A total)Configurable as: Open Collector, with 2VDC or VBus(15VDC) potential

    Internal voltage supply for LED 1.9-2.2 VDC (max.1A) to drive LEDs on the ports directly

    Part. No. N155

  • 8/12/2019 NOX Components Overview July 2011

    27/64

    Components Overview July 2011 Page 27 / 64

    NOX M31, Mini In-/Output Module

    The NOX M31 is a small, compact module with one open collector output and three inputs, itsdesigned to fit directly into the case of a detector.The module has 3 non resistance monitored inputs (e.g. for external contacts).

    SpecificationCase none

    Tamper Monitoring Connection available

    Dimensions (L x W x H) 28 x 20 x 10 mm

    Connection to the control unit NOX Bus

    Inputs 3 none resistance monitored Inputs (open / closed)

    Outputs 1 Open Collector Output (max.output current 50mA)

    Part. No. N121

  • 8/12/2019 NOX Components Overview July 2011

    28/64

    Page 28 / 64 Components Overview July 2011

    NOX MIO Rev.B, Multi Input/Output Module

    The MIO Rev.B module can be used e.g. to connect an alarm transmission unit and to drive sirensand flash bulbs. As external version it can be used in a similar way but decentralized.

    N105 (NOX MIO Rev.B internal) N105e (NOX MIO Rev.B external)

    Specification (NOX MIO Rev.B external)

    Case Plastic, whiteTampe Monitoring Integrated, through tamper contact

    Dimensions (L x W x H) 150 x 100 x 36 mm

    Connection to the control unit NOX Bus

    Inputs 4 resistance monitored Inputs

    Outputs

    8 potential-free Relay Outputs(max. contact rating 30V/1A)4 Open Collector Outputs, individually fused(max. current for a single output 500mA)

    Part. No. N105e

    Specification (NOX MIO Rev.B internal)Case None

    Tamper Monitoring Through vibration sensorDimensions (L x W x H) 120 x 67 x 12 mm

    Part. No. N105All other specifications are identical with part no. N105e.

  • 8/12/2019 NOX Components Overview July 2011

    29/64

    Components Overview July 2011 Page 29 / 64

    NOX UP4, In- / Outputmodule in Feller Edizio DueDesign

    The UP4 module offers four resistance monitored inputs to connect detectors and indicators to theNOX Bus.

    Unique is the separate adjustable resistor monitoring range from 3 kup to 40 kfor each Input.This allows connecting different types of detectors and indicators and migrate existinginstallations. An individual time delay can be set for each input.The module supports Tripple end of line resistors. This allows covering alarm, tamperingmonitoring and anti mask detection on one inputting only.

    Additional the module has 2 open collector outputs integrated.

    SpecificationCase Feller Edizio Due Designframe with cover, white

    Dimensions (L x W x H)(incl. Feller Frame)

    88 x 88 x 35 mm

    Tamper Monitoring Integrated, through tamper contactConnection to the control unit NOX Bus

    Inputs 4 resistance monitored Inputs

    Outputs2 Open Collector Outputs(max. current for a single output 200mA)

    Part. No. N251

  • 8/12/2019 NOX Components Overview July 2011

    30/64

    Page 30 / 64 Components Overview July 2011

    NOX IR1, NOX Bus I/O Module for Alarmcom IR270TDetector

    Backside View Component Side ViewWith this I/O module an Alarmcom IR270T detector can be connected to the NOX Bus. The

    module is mounted into the case of the detector.

    SpecificationCase none

    Dimensions (L x W x H) 45 x 44 x 10 mm

    Tamper Monitoring Functionality of the detector

    Inputs Alarm-, Tamper- and Antimask contacts

    Outputs NOX Bus; Detector arm/disarm, Detector Walktest

    Part. No. N151

  • 8/12/2019 NOX Components Overview July 2011

    31/64

    Components Overview July 2011 Page 31 / 64

    NOX Bus Cardreader Interfaces

    NOX CRx, Cardreader Interface Modules

    Card readers from different manufacturers (e.g. Legic, Temic, Mifare, Hitag) with Wiegand orData/Clock interfaces can be connected with the NOX CRx interface modules to the NOX Bus. Inaddition to the cardreader interface the NOX CRx modules have one resistance monitored inputand one relay output.

    Specification (NOX CRx) generally

    Case Plastic ABS, white (DASK Case)Tamper Monitoring Integrated, through tamper contact

    Dimensions (L x W x H) 85 x 66 x 27mm

    Connection to the control unit NOX Bus

    Input 1 resistance monitored Input

    Output 1 relay output (30V/1A)

    Variants of the NOX CRx, Cardreader, Interface ModulesDescription Part No.NOX CRD, with 26Bit Wiegand Interface N115NOX CRA, with Data/Clock Interface (Omron Protocol) N125NOX CRB, with 40Bit Wiegand Interface N126NOX CRC, with 27Bit and 40Bit Wiegand Interface for HID iCLASS

    reader N127NOX CRE, with Data/Clock Interface (Omron Protokoll) and keyboard

    supportN128

    NOX CRF, with 26Bit Wiegand Interface and keyboard support N129NOX CRG, with Data/Clock Interface (Omron Protocol) for Acticon and

    ABI card readersN130

    NOX CRH, forHID RK40 N131NOX CRU, for Wiegand Interface up to 80Bit paket length (universal)

    compatible with CRC, CRD and CRHN132

  • 8/12/2019 NOX Components Overview July 2011

    32/64

    Page 32 / 64 Components Overview July 2011

    NOX CMx, Cardreader Interface Module with OfflineFunctions

    The NOX CMx module offer additionally to the usual CRx functions an offline functionalityif the

    connection to the control unit may gets interrupted. The NOX CMx can store 204 to 251 cardcodes directly.

    Specification (NOX CMx) generalCase Plastic ABS, white (DASK Case)

    Tamper Monitoring Integrated, through tamper contact

    Dimensions (L x W x H) 85 x 66 x 27mm

    Offline Functions204 to 251 batch cards are non volatile storedFormulas can be evaluated locally in the module (e.g. for

    door opener)Connection to the central unit NOX Bus

    Input 1 resistance monitored Input

    Output 1 Relay Output (30V/1A)

    Variants of the NOX CMx, Cardreader Interface modules with offline functionality. (Non volatilememory for 251 fix programmed cards if not specified otherwise).Description Art. No.NOX CMD, with 26Bit Wiegand Interface N215NOX CME, with Data/Clock Interface (Omron Protocol) and keyboard

    supportN228

    NOX CMF, with 26Bit Wiegand Interface and keyboard support N229NOX CMI, for UNITEK Cardreader with keyboard support N230NOX CML, for 50Bit Aras Cards N231NOX CMU, for Wiegand Interface 26..80Bit paket lenght (universal)

    Memory for total 204 cards:24 complete programmed cards180 cyclic cards (dynamic)

    N232

  • 8/12/2019 NOX Components Overview July 2011

    33/64

    Components Overview July 2011 Page 33 / 64

    NOX Bus Repeater / Converter andCommunication Modules

    NOX RPT, NOX Bus Repeater / Converter

    The NOX RPT Module runs as a universal bus repeater (RS-485 up to RS-485) or alternatively asserial RS-232 interface (RS485 to RS-232). The function can be defined with the jumper on themodule. The repeater allows an almost unlimited extension of the the bus cable length.The module decouples two bus lines, therefore bus communication problems are decreased. Inaddition the bus output is fused separately.

    N141

    Specification (NOX RPT, NOX Bus Repeater)Case Plastic ABS, white (DASK Case)

    Tamper Monitoring Integrated, through tamper contact

    Dimensions (L x W x H) 85 x 66 x 27mm

    Connection to the control unit NOX Bus

    Input NOX Bus

    Output NOX Bus

    Part. No. N141

    Specification (NOX RPT RS232, NOX Bus Converter)Case Plastic ABS, white (DASK Case)

    Tamper Monitoring Integrated, through tamper contact

    Dimensions (L x W x H) 85 x 66 x 27mm

    Connection to the control unit NOX BusInput NOX Bus

    Output RS-232 with DB9 receptacle

    Part. No. N141A

  • 8/12/2019 NOX Components Overview July 2011

    34/64

    Page 34 / 64 Components Overview July 2011

    NOX ATU, Serial Communication Interface with ATUProtocol

    The NOX ATU module connects a NOX System with an alarm transmission device with ATU(Alarm Transmission Unit) protocol.

    SpecificationCase Plastic ABS, white (DASK Case)

    Tamper Monitoring Integrated, through tamper contact

    Dimensions (L x W x H) 85 x 66 x 27mm

    Connection to the control unit NOX Bus

    Input NOX Bus

    OutputRS-232 with ATU Protocol (Transmission from SIA Level 2commands)

    Part. No. N144

  • 8/12/2019 NOX Components Overview July 2011

    35/64

    Components Overview July 2011 Page 35 / 64

    NOX ESP, Serial Interface with several Protocols

    The NOX ESP module supports the ESPA, IRIS and Musdo protocols and acts as a serialinterface (RS-232) to various Alarm Transmission Systems.

    SpecificationCase Plastic ABS, white (DASK Case)

    Tamper Monitoring Integrated, through tamper contact

    Dimensions (L x W x H) 85 x 66 x 27mm

    Connection to the control unit NOX Bus

    Input NOX Bus

    Output

    RS-232 with following protocols- ESPA 4.4.4 (Paging)-Chiron IRIS (SIA Level 2 / 3 Protocol), alarm transmission-Musdo, alarm transmission

    Part. No. N147

  • 8/12/2019 NOX Components Overview July 2011

    36/64

    Page 36 / 64 Components Overview July 2011

    NOX Bus Extension via TCP/IP

    NOX MXA, Bus Extension via TCP/IPWith NOX MXA a standard NOX Bus can be connected to a NOX Security System via TCP/IP.This Bus acts in the same manner as a direct connected NOX Bus.

    N202

    Specification (NOX MXA Components)Connection to the control unit Through TCP/IPOutput NOX Bus

    Scope of delivery-MOXA Nport 5110, pre configured-modified NOX RPT Module

    Part. No. N201

    Specification (NOX MXA on mounting plate)Installation plate Aluminium

    Dimensions (L x W x H) 300 x 207 x 3 mm

    Mounting 4 x 4.5mm drills

    DASK Case 5 pieces pre-assembled on mounting plate

    Scope of delivery

    Pre-assembled, wired and tested on mounting plate

    -N201, NOX MXA components-5 x DASK Case, pre-installed-1 Cable channel

    Part. No. N202An additional Power supply (NOX PS5) for an auxiliary Bus is not integrated.With each NOX MXA up to 200 additional NOX Bus modules can be connected to the system.

  • 8/12/2019 NOX Components Overview July 2011

    37/64

    Components Overview July 2011 Page 37 / 64

    NOX MXA mini, Mini Bus Extension via TCP/IPThe NOX MXA mini has the same functionality as the NOX MXA but it has only 1 empty DASKcase.

    SpecificationBaseplate Aluminium

    Dimensions (L x W x H) 226 x 165 x 3 mm

    Mounting 4 x 4.5mm holes

    DASK Case 5 pieces mounted on Baseplate

    Scope of delivery

    Mounted, wired and tested on baseplate:-N201, NOX MXA Components-1 x DASK Case, wired-1 Cable channel

    Part. No. N203

  • 8/12/2019 NOX Components Overview July 2011

    38/64

    Page 38 / 64 Components Overview July 2011

    Interface Module for Third Party Systems

    NOX IS9, Interface for SAEL S9 (SECULON)

    The NOX IS9 Interface allows to connect bus units from the SAEL S9 (Seculon) security system tothe NOX Bus. All devices of the SAEL S9 system can be integrated into the NOX system (exceptcontrol panel and power supply).

    SpecificationBaseplate Aluminium

    Dimensions (L x W x H) 155 x 120 x 30 mm

    Mounting direct into the NOX control unit housing

    Input NOX Bus

    Outputs4 x SAEL S9 Bus connections with individual fusing(max. 99 S9 devices for one S9 Bus connection)

    Scope of delivery NOX IS9 assembled on Baseplate

    Part. No. N143

  • 8/12/2019 NOX Components Overview July 2011

    39/64

    Components Overview July 2011 Page 39 / 64

    NOX S8P RevC, Interface for SAEL S8 (PRISMA)

    The NOX S8P RevC Interface module is used to connect bus devices from SAEL S8 (Prisma)

    system to the NOX Bus.

    SpecificationCase Plastic, white

    Tamper Monitoring Integrated, through tamper contact

    Dimensions (L x W x H) 150 x 100 x 36 mm

    Input NOX Bus

    Output 2 x SAEL S8 LAN Port

    Part. No. N149

  • 8/12/2019 NOX Components Overview July 2011

    40/64

    Page 40 / 64 Components Overview July 2011

    NOX IFT, Interface to Thor Bus

    The IFT Interface module converts the Thor Bus to the NOX Bus. It supports S-Art modules ofType 1xxx and 2xxx (Inputs and Outputs).SpecificationCase None (fits into MIO case)

    Tamper Monitoring Integrated, through tamper contact(is only active with MIO PVC )

    Dimensions (L x W x H) Print (PCB) 118 x 55 x 15 mm

    Input NOX Bus

    Output 4 x Thor Bus connections

    Part. No. N148

  • 8/12/2019 NOX Components Overview July 2011

    41/64

    Components Overview July 2011 Page 41 / 64

    NOX ABI M-Bus, Interface to ABI Control Unit with M-Bus

    The NOX ABI interface allows to connect M-BUS devices of the ABI systemt (e.g. MC1500) to theNOX Bus. The Interface has two pieces; a NOX ABI and a NOX ISA module.

    SpecificationCase 2 x Plastic ABS, white (DASK case)

    Tamper Monitoring Integrated (in both cases), trough tamper contact

    Dimensions (L x W x H) per Case 85 x 66 x 27 mm

    Input NOX Bus (on NOX ABI)

    Output M-Bus (on NOX ISA)

    Scope of delivery-NOX ABI, Interfacecard with NOX Bus-NOX ISA, Interfacecard with 1 x M-Bus port(for every M-Bus up to 120 ABI devices can be connected)

    Part. No. N145

    Supported ABI devices:15191/15190 LAM 2 Inputs, 2 Outputs15198 LAM-4 8 Inputs, 2 Outputs15196 IOM 4 Inputs, 2 Relays15193 RLM 2 Relays15192 BLM Block lock module

    All inputs and output modules are programmable.

  • 8/12/2019 NOX Components Overview July 2011

    42/64

    Page 42 / 64 Components Overview July 2011

    NOX RXP, Wireless Receiver for Paradox Detectors

    NOX RXP wireless receiver allows to integrate wireless motion detectors, door contacts, wirelessportable transmitter, magnetic switches and remote controls of different systems from ParadoxSecurity Systems, Canada.The receiver ist connected to the NOX bus. Multiple receivers can beused for larger installations. The transmitter can be used to arm and disarm areas or as panicalarm button.

    Supported Paradox Devices:

    Wireless Motion Detector (e.g. PMD1P)

    Wireless Doorcontact (e.g. DCTXP2)

    Wireless Portable Transmitter (e.g. REM1, RAC1, REM15)

    Wireless Fire Warning Detector (e.g. SD738)

    SpecificationCase PVC, white

    Dimensions (L x W x H) 172 x 155 x 28mm (without antenna)

    Input NOX Bus

    Output4 x SAEL S9 Bus connections with individual fusing(max. 99 S9 devices per S9 Bus connection)

    Scope of delivery-Paradox, Wireless expansion Module RTX3-Adapter module to the NOX Bus assembled and wired inthe paradox housing

    Part. No. P221

  • 8/12/2019 NOX Components Overview July 2011

    43/64

    Components Overview July 2011 Page 43 / 64

    NOX Sensors

    NOX THS, Temperature and Humidity Sensor

    The NOX THS measures the air temperature andhumidity in rooms. Its available for indoor oroutdoor use. The measured values are transmitted through the NOX Bus to the control unit and forfurther processing. For both physical values an upper and a lower threshold can be set. Thetriggered warnings and alarms can be linked and evaluated as desired by software formulas. Withthe integrated relay a fan and air conditioner may be controled. The readings are stored for oneyear.On a PC trending for the last day, month or year is selectable.

    Specification (NOX THS internal)Case Plastic ABS, white (DASK Case)

    Temper Monitoring Integriert, through tamper contact

    Dimensions (L x W x H) 85 x 66 x 27 mm

    Input NOX Bus

    Output 1 Relay output potential-free(max. contact rating 30V/1A)

    Sensorsprecise combined sensor for temperature and relativehumidity

    Part. No. N150i

    Specification (NOX THS external)Sensorconnection 3m Cable, 4 strands

    Sensor Case Duropol, black

    Sensor Dimensions 30 x 20 x 15 mm

    Sensor protection class (IEC60529:2001)

    IP 67 (only with Temperature sensor)

    Scope of delivery

    - NOX Bus Module to connect a temperature/humiditysensor

    - external temperature and relative humidity sensor with 3mcable

    Part. No. N150eAll other specifications are identical with part no. N150i.

  • 8/12/2019 NOX Components Overview July 2011

    44/64

    Page 44 / 64 Components Overview July 2011

    NOX THT, Wireless Temperature and Humidity Sensor

    See also Wireless Components of NOX Picture Monitoring System (PMGS).

    The wireless NOX THT module measures temperature and relative humidity of the room air.The NOX RXM wireless receiver receives actually measured values and passes it on over theNOX BUS to the control unit.

    SpecificationCase Plastic white

    Protection class (IEC 60529:2001) IP 40

    Dimensions (L x W x H) 58 x 51 x 13mm

    Temperature range25C: 0.3C0 bis +40 C: 0.5C

    -20C bis +70C: 1.0CHumidity range

    10 bis 90% RH: 2%90% RH: 4%

    Wireless rangeUnder open field conditions: 300mInside of buildings:line of sight

    SettingsAdjustable transmission interval (8 levels) at change oftemperature or humidity reading

    Power supply 2 x 1.5V Alkaline batteries AAAA

    Battery life time 1 up to 2 years, dependent on the quantity of transmissions

    Scope of delivery-NOX THT, wireless temperature and humidity sensor-2 pieces batteries Alkaline AAAA-Velcro Tape for easy mounting

    Part. No. N159

  • 8/12/2019 NOX Components Overview July 2011

    45/64

    Components Overview July 2011 Page 45 / 64

    NOX FLD, Water Detector

    In rooms with invaluable goods or equipment like museums, server and computer rooms, centralheating room or in storage rooms serious property damage can happen in case of water ingress.NOX FLD detects the ingress of any conducting liquids in a reliable manner for many years.

    SpecificationCase PVC grey

    Protection class (IEC 60529:2001) IP 68 (water and dust proof)

    Dimensions (L x W x H) 55 x 39 x 12 mm

    Length Sensor Cable 3m

    Detectable Liquids All with a conductivity 150S

    Response time 5ms

    Sensor Output Open Collector

    Connection to the Control Unit e.g. with a NOX Module, NOX IO1, NOX IO4 or similar

    Part. No. M801

  • 8/12/2019 NOX Components Overview July 2011

    46/64

    Page 46 / 64 Components Overview July 2011

    Wireless Components of NOX PictureMonitoring System (PMGS)

    Wireless receiver modules

    NOX RXM, Wireless Receiver Module with NOX BusReceiver for the 868 MHz wireless signal from the NOX PMGS transmitters. The module has aNOX bus connection. This module is monitored (as all other NOX bus modules) by the CPU forsabotage.For monitoring purposes of the RF link, a reference transmitter (NOX TXM REF) can bei linked(configuration) with one or more receiver modules.

    SpecificationCase Plastic ABS, white (DASK case)

    Tamper Monitoring Integrated, through tamper contact

    Dimensions (L x W x H) 85 x 66 x 27mm (L=145mm with antenna)

    Connection to the control unit NOX Bus

    Part. No. P110

  • 8/12/2019 NOX Components Overview July 2011

    47/64

    Components Overview July 2011 Page 47 / 64

    NOX RXR, Wireless Receiver Module with RelayReceiver for the 868 MHz wireless signal from the NOX PMGS transmitters. The module isindependent from the NOX control unit (no NOX Bus connection) and can be used to integrate theNOX Picture Monitoring System (PMG) into security systems of third party manufacterer.

    SpecificationCase Plastic ABS, white (DASK case)

    Tamper Monitoring Integrated, through tamper contact

    Dimensions (L x W x H) 85 x 66 x 27mm (L=145mm with antenna)

    Output

    3 Relay output potential-free

    (max. contact rating 30V/1A)-Collective alarm pictures-Collective alarm external contacts-Collective alarm sabotage/battery malfunction

    Part. No. P220

  • 8/12/2019 NOX Components Overview July 2011

    48/64

    Page 48 / 64 Components Overview July 2011

    NOX BPR, portable alerting receiverThe portable receiver with beltclip receives the 868MHz RF signals from the PMGS picture alarmdetectors. In this compact case a red alarm LED, a green status LED, On/Off side switch and analarm buzzer are integrated.

    SpecificationCase Plastic ABS, white with beltclip

    Dimensions (L x W x H) 120 x 65 x 23mm

    Weight 80g incl. batteries

    DisplayStatus LED, green

    Alarm LED, red

    Alarming with LED and buzzer (integrated)

    Antenna Integrated

    Power Supply 2 x 1.5V batteries AAPart. No. P102

  • 8/12/2019 NOX Components Overview July 2011

    49/64

    Components Overview July 2011 Page 49 / 64

    Wireless transmitter modules

    NOX TXM, wireless picture detectorThe PMGS wireless picture detector indicates micromotion and touches of objects.The sensitivity is adjustable within 8 steps by a digital micro switch.

    The module is free of toxic materials in comarison to mercury switches. The detector module hasthe CE Label and it does not interfere with other wireless devices.

    SpecificationCase Plastic ABS, white

    Dimensions (L x W x H) 105 x 58 x 19mm

    Weight 80g incl. batteries

    Functional principle Vibration, 8 level of sensitivity

    Alarming Via RF and integrated buzzer

    Antenna Integrated

    Wireless rangeUnder open field conditions: 300mInside of buildings: line of sight

    Connections 1 x connection for an external contact

    Power Supply 2 x 1.5V Alkaline batteries AAA

    Part. No. P111

  • 8/12/2019 NOX Components Overview July 2011

    50/64

    Page 50 / 64 Components Overview July 2011

    NOX TXS, Wireless Picture Detector MiniThe NOX TXS module is a mini version of the TXM module. The functionality is identiacal with theNOX TXM module.

    SpecificationCase Plastic PVC, grey; Epoxy cover dark green

    Dimensions (L x W x H) 58 x 51 x 13mmWeight 45g incl. batteries

    Functions of the sensors Vibration, 8 level of sensitivity

    Alarming Via RF

    Antenna Integrated

    Wireless rangeUnder open field conditions: 300mInside of buildings: line of sight

    Connections 1 x connection for an external Contact

    Power Supply 2 x 1.5V Alkaline batteries AAAA

    Part. No. P112

  • 8/12/2019 NOX Components Overview July 2011

    51/64

  • 8/12/2019 NOX Components Overview July 2011

    52/64

    Page 52 / 64 Components Overview July 2011

    NOX TXM REF, Radio Reference TransmitterWith the NOX TXM REF reference transmitter its possible to supervise the RF link between thetransmitter and one or more receivers (NOX RXM).

    SpecificationCase Plastic ABS, white

    Dimensions (L x W x H) 105 x 58 x 19mmWeight 80g

    Alarming Via RF, in malfunction of the reference signal

    Antenne Integrated

    Wireless rangeUnder open field conditons: 300mInside of the building: line of sight

    Transmitter interval Adjustable from 10..80s

    Power supply External power supply, 7..20VDC, 0.1W

    Part. No. P999

  • 8/12/2019 NOX Components Overview July 2011

    53/64

    Components Overview July 2011 Page 53 / 64

    NOX THT, Wireless Temperature and Humidity SensorThe wireless NOX THT module measures the temperature and relative humidity of the air inrooms.The readings are transmitted to the NOX RXM RF receiver which transfers it via NOX Bus to theNOX control unit.

    SpecificationMaterial Plastic, white

    Protection class (IEC 60529:2001) IP 40

    Dimensions (L x W x H) 58 x 51 x 13mm

    Temperature range25C: 0.3C0 bis +40 C: 0.5C-20C bis +70C: 1.0C

    Humidity range10 to 90% RH: 2%90% RH: 4%

    Wireless rangeUnder open field conditions: 300mInside of buildings: line of sight

    Adjustable Options

    Adjustable Transmission interval (8 levels) for temperature

    and humidity valuesPower Supply 2 x 1.5V Alkaline batteries AAAA

    Batterie lifetime 1 up to 2 Years, it depends on the number of transmissions

    Scope of delivery-NOX THT, wireless temperature and humidity sensor-2 pieces alkaline batteries AAAA-Velcro tape for easy mounting

    Part. No. N159

  • 8/12/2019 NOX Components Overview July 2011

    54/64

    Page 54 / 64 Components Overview July 2011

    Supplies / Accessories

    Mounting Plate

    Empty Plate for 8 DASK Cases

    SpecificationMaterial Aluminium

    Dimensions (L x W x H) 300 x 207 x 3 mm

    Mounting16 x M3 threads to attach 8 DASK Cases3 x M3 threads to attach a 30mm wide cable channel4 x 4.5mm holes for the montage of the aluminium plate

    DASK Case None

    Part. No. T501

    Mounting Plate with 8 DASK Cases and Cables

    Specification

    Mounting plate AluminiumDimensions (L x W x H) 300 x 207 x 3 mm

    Mounting16 x M3 threads to attach 8 DASK Cases3 x M3 threads to attach a 30mm wide cable channel4 x 4.5mm holes to mount the plate

    DASK Case 8 pieces preassemble on montage plate

    Scope of delivery

    Preassembled and prewired on mounting plate:-8 x DASK Case-8 x Bus terminals-1 Cable channel

    Part. No. T502

  • 8/12/2019 NOX Components Overview July 2011

    55/64

    Components Overview July 2011 Page 55 / 64

    Mounting Plate with 8 DASK Cases

    SpecificationMounting plate Aluminium

    Dimensions (L x W x H) 300 x 207 x 3 mm

    Mounting16 x M3 threads to attach 8 DASK Cases3 x M3 threads to attach a 30mm wide cable channel

    4 x 4.5mm holes to mount the plateDASK Case 8 pieces preassembled on the mounting plate

    Scope of deliveryPreassembled on mounting plate:-8 x DASK Case-1 Cable channel

    Part. No. T503

    Empty Plate for 4 DASK Cases

    SpecificationMaterial Aluminium

    Dimensions (L x W x H) 226 x 165 x 3 mm

    Mounting8 x M3 threads to attach 4 DASK Cases2 x M3 threads to attach a 30mm wide cable channel4 x 4.5mm holes to mount the plate

    DASK Case none

    Part. No. T505

  • 8/12/2019 NOX Components Overview July 2011

    56/64

    Page 56 / 64 Components Overview July 2011

    Mounting Plate with 4 DASK Cases and Cables

    SpecificationMounting plate Aluminium

    Dimensions (L x W x H) 226 x 165 x 3 mm

    Mounting8 x M3 thread to attach 4 DASK Cases2 x M3 threads to attach a 30mm wide cable channel

    4 x 4.5mm holes to mount the plateDASK Case 4 pieces preassembled on the mounting plate

    Scope of delivery

    Preassembled and pre-wired on montage plate:-4 x DASK Case-4 x Bus terminal-1 Cable channel

    Part. No. T506

    NOX TNA, Empty Mounting PlateSpecificationMaterial Aluminium

    Dimensions (L x W x H) 245 x 182 x 3 mm

    Mounting6 x 4mm holes to mount the platein the old or new Control Unit housing

    Part. No. T504

  • 8/12/2019 NOX Components Overview July 2011

    57/64

    Components Overview July 2011 Page 57 / 64

    DASK Case

    SpecificationMaterial Plastic ABS,white

    Dimensions (L x W x H) 85 x 66 x 27 mm

    Scope of delivery Empty Case with 2 x M3x16 mm screwsPart. No. T552

    PCBA Fixation for DASK Case

    SpecificationMaterial Plastic PVC, black

    Scope of delivery 2 x fixation with screws M3x14 mm

    Part. No. T551

  • 8/12/2019 NOX Components Overview July 2011

    58/64

    Page 58 / 64 Components Overview July 2011

    Batteries

    Typ AAAA Typ AAA Typ AA

    SpecificationPart. No. Type DescriptionT701 AA Alkaline Batteries 1.5V (for NOX BPR) Set with 2 piecesT702 AAA Alkaline Batteries 1.5V (for NOX TXM / TXK) Set with 2 piecesT703 AAAA Alkaline Batteries 1.5V (for NOX THT / TXS) Set with 2 pieces

    Cables

    Cables for the Control Unit: see under Control Units Spare Parts and Single Components P.8.

    Cable NOX Bus, 4th Dask Plate

    SpecificationCable 4 x PVC stranded wire, 1mm

    2

    Length 3 x 20cm

    NOX Bus Connections 4 x 4 poles, Type Phoenix

    Part. No. T526

  • 8/12/2019 NOX Components Overview July 2011

    59/64

    Components Overview July 2011 Page 59 / 64

    Cable NOX Bus, 8th Dask Plate

    SpecificationCable 4 x PVC stranded wire, 1mm

    2

    Length 7 x 20cm

    NOX Bus Connections 8 x 4 poles, Type Phoenix

    Part. No. T527

    NOX Bus Terminal

    SpecificationType Phoenix Contact

    Number of connections 4

    Part. No. N187

  • 8/12/2019 NOX Components Overview July 2011

    60/64

    Page 60 / 64 Components Overview July 2011

    USB Cable to CPU_V3 MotherboardThis cable makes it possible to update the operating system of the Toradex CPU module which isa component of the NOX CPU V3.

    SpecificationTyp USB 1.1 Cable

    Length 0.6m

    Connection USB Cable receptacle Type A female

    Scope of deliveryCable assembledWithout USB memory stick

    Part. No. T530

  • 8/12/2019 NOX Components Overview July 2011

    61/64

    Components Overview July 2011 Page 61 / 64

    Spare Fuses for NOX Modules

    This SMD fuse type is used within the following NOX modules:PSU, PS2, PS5, CPU V1, CPU V2, CPU V3 MIO, MIOe, RPT, S8P, IS9, IFTThe rated current is dependent of the module and the specific application.

    General Specification

    Manufacturer LittlefuseType SMD Fuse, 452 Series

    Outline shape Nano2 (6.1 x 2.69 mm)

    SMD Fuse Set 500mATSpecificationCharacteristic slow blowFuses per set 25Rated Current 500mA

    Part No. N301

    SMD Fuse Set 1ATSpecificationCharacteristic slow blowFuses per set 25Rated Current 1A

    Part No. N302

    SMD Fuse Set 2ATSpecificationCharacteristic slow blowFuses per set 25Rated Current 2A

    Part No. N303

    SMD Fuse Set 3ATSpecificationCharacteristic slow blowFuses per set 25Rated Current 3A

    Part No. N304

    SMD Fuse Set 5ATSpecificationCharacteristic slow blowFuses per set 25Rated Current 5A

    Part No. N305

  • 8/12/2019 NOX Components Overview July 2011

    62/64

    Page 62 / 64 Components Overview July 2011

    NOX Software Components

    NOX Config, PC Configuration Software for the NOXSecurity SystemConfiguration- and diagnostic software for start-up and maintenance of the NOX systems.Functionality:

    Update of the NOX System Software

    Management of customized configurations

    Detailed system informations

    Maintenance functionality

    Access to all logs

    Online user interface to the system

    Online Terminalwindow with realtime output

    Part. No. S400

    NOX PC Control PanelPC Control Panel for the end user.Offers an easy but still complete operation of the security system on userlevel:

    Arm / disarm of areas

    Activate / deactivate of detectors

    View and acknowledge of alarms and warnings

    Shows all system logs

    Define of filter rules to view log entries

    Shows actual temperature / humidity sensor readings and history

    Change of temperature / humidity threshold values

    Shows information about picture monitoring detectors (incl. battery voltages)

    Management of user profiles and user codes

    Managment of time profiles

    Licence None

    Configuration Runs directly without configuration

    Supported operating systems Microsoft Windows 2000, XP, Vista, 7 (32 and 64Bit)

    Part. No. S401

  • 8/12/2019 NOX Components Overview July 2011

    63/64

    Components Overview July 2011 Page 63 / 64

    NOX PC TPA Licence, PC Touch Panel SoftwareLicenceThe Touch Panel Software is designed to be used with a PC (with or without Touch Panel).The interaction with the system happens directly over the floor plans of the building.

    Supported functions: Arm / disarm of areas

    Activate / deactivate of detectors

    Alarm view and acknowledge

    Shows actual temperature / humidity sensor readings

    Shows all system logs

    Management of user codes

    Shows system state informations in the floor plans

    Licence1 End user licence for each control unit(e.g. the TPALoader software can be installed on anynumber of PC)

    ConfigurationThe Module NOX TPA must be configured in the NOXControl Unit

    Supported operating systems Microsoft Windows 2000, XP, Vista, 7 (32 and 64Bit)

    Part. No. S100

    Compatibility

    This licence runs with:

    PCTPALoader.exe (Application TPA V1.00 toV1.99e which runs on TPA Rev.A and TPA Rev.BHardware as well), not for new installations!

    PCTPA2Loader.exe (Application TPA V2.00 toactual Version which runs on TPA Rev.C Hardwareas well)

    NOX SIMS, Security Information Managment SystemProfessional security information management system with up to 128NOX Control Units for up to 32 PC Workstations. It supports differentIntrusion detection systems, fire detection systems and buildingautomation systems.

    Base licence for 1 PC Workstation

    Part. No. S405

    Additional licence for 1 PC Workstation

    Part. No. S407

    NOX Logger

    Stores all system logs as text file to a network drive (e.g. server). Thisresults in nearly unlimited recording of all system actions. The history of alltemperature and humidity sensors are stored as well.

    Part. No. S402

    NOX Time

    Tracking of the labour time with direct connection to the NOX Control Unit.Staff members start and stop tracking by using control panel or card reader.Unlimited number of employees.

  • 8/12/2019 NOX Components Overview July 2011

    64/64

    Part. No. S404

    NOX iNOX

    App to view and control of NOX security systems by iPhone (smartphone) or iPad (Tablet PC).The App allows to view and acknowledge alarms and warnings, arm and disarm of areas and theaccess the logs of the NOX system.This software application runs on all supported Apple platforms.

    Licence 1 Licence, bound to the user (Apple Licence)

    Requirements NOX Security System must be reachable from the Internet

    Supported Apple platforms

    iPhone 3

    iPhone 4

    iPad

    iPad 2

    Distribution through Apple iTunes Store iNOX

    NOX iOS

    Adds floor plans of the building to the iNOX App. Thus the NOX Security system can becontrolled direct over the floor plans.

    Licence Bound to a NOX CPU

    RequirementsNOX iNOX application (distributed throug the Apple iTunesStore). Optimized floor plans and adequate data points for theindividual system configuration.

    Supported Apple Platforms Identically with iNOX

    Part. No. S408