ns0-171.exam€¦ · ns0-171.exam.34q number : ns0-171 passing score : 800 time limit : 120 min ...

24
https://www.gratisexam.com/ NS0-171.exam.34q Number : NS0-171 Passing Score : 800 Time Limit : 120 min https://www.gratisexam.com/ NS0-171 FlexPod Implementation and Administration

Upload: others

Post on 02-Jun-2020

18 views

Category:

Documents


1 download

TRANSCRIPT

https://www.gratisexam.com/

NS0-171.exam.34q

Number: NS0-171Passing Score: 800Time Limit: 120 min

https://www.gratisexam.com/

NS0-171

FlexPod Implementation and Administration

https://www.gratisexam.com/

Exam A

QUESTION 1Which set of commands maps VLAN 100 to VSAN 100?

https://www.gratisexam.com/

A. Nexus 5000-A#configure terminalNexus 5000-A (config) # vlan 100Nexus 5000- A (config-vlan_ #fcoe vsan 100

B. Nexus 5000-B# configure terminalNexus 5000-B (config) # vsan databaseNexus 5000-B (config-vsan)# vsan 100Nexus 5000-B(config- vsan) #vsan 100 name FCoE-VLAN 100

C. Nexus 5000-A#configure terminalNexus 5000-B (config) # vsan databaseNexus 5000-A (config)# vsan 100Nexus 5000-A (config-vsan) # fcoe vsan 100

D. Nexus 5000-B# configure terminalNexus 5000-B(config-vsan) # vlan 100Nexus 5000-B (config-vsan)# vsan 100 name vsan100

Correct Answer: ASection: (none)Explanation

Explanation/Reference:Reference https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/fcoe/421_n1_1/b_Cisco_n5k_fcoe_config_gd_re_421_n1_1/Cisco_n5k_fcoe_config_gd_re_421_n1_1_chapter4.html

QUESTION 2Which feature allows Cisco Nexus 7000 Series switches to be virtualized at the device level?

A. PONG

B. VLAN

https://www.gratisexam.com/

C. VRF

D. VDC

Correct Answer: DSection: (none)Explanation

Explanation/Reference:Reference https://www.cisco.com/c/en/us/products/collateral/switches/nexus-7000-10-slot-switch/White_Paper_Tech_Overview_Virtual_Device_Contexts.html

QUESTION 3A Cisco UCS chasis has two power suppliers connected to one PDU and two power supplies connected to another PDU. You would like to protect against thefailure of one entire PDU.

In this scenario, which power policy should you configure in UCS Manager?

A. N+1

B. redundant

C. N+2

D. grid

Correct Answer: DSection: (none)Explanation

Explanation/Reference:Reference https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/3-0/b_UCSM_GUI_User_Guide_3_0/b_UCSM_GUI_User_Guide_3_0_chapter_0100010.html

QUESTION 4Your customer needs a new Nexus switch that can support at least ten 40GbE ports, and has room for future growth. Your customer would also like the new switchto be Application Centric Infrastructure- ready.

Which switch meets these requirements?

A. Nexus 7004

B. Nexus 5672

C. Nexus 6004

D. Nexus 9504

https://www.gratisexam.com/

Correct Answer: DSection: (none)Explanation

Explanation/Reference:Reference https://www.cisco.com/c/en/us/products/collateral/cloud-systems-management/application-policy-infrastructure-controller-apic/datasheet-c78-732414.html

QUESTION 5After deploying a FlexPod solution, which tool would you use to validate a successful installation?

A. Hardware Universe

B. Config Advisor

C. System Manager

D. UCS Manager

Correct Answer: CSection: (none)Explanation

Explanation/Reference:Reference https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_saphana_n9k_aff.html

QUESTION 6You are attempting to establish a cluster peer relationship between two NetApp clusters, but the peering process fails.

What is a cause for this failure?

A. The intercluster LIF on each node cannot communicate with the intercluster LIF on each node in the peer cluster.

B. The cluster LIFs on each node cannot communicate with the cluster LIFs on each node in the peer cluster.

C. The node management LIF on each node cannot communicate with the node management LIF on each node in the peer cluster.

D. The cluster management LIF for the cluster cannot communicate with the cluster management LIF for the peer cluster.

Correct Answer: ASection: (none)Explanation

Explanation/Reference:

https://www.gratisexam.com/

QUESTION 7The NetApp Vistual Storage Console is used to set which three setting categories on ESXi hosts? (Choose three.)

A. MPIO Settings

B. Adapter Settings

C. Logging Settings

D. NFS Settings

E. Security Settings

Correct Answer: ABDSection: (none)Explanation

Explanation/Reference:Reference https://library.netapp.com/ecm/ecm_download_file/ECMLP2371569

QUESTION 8A server administrator calls you complaining that an uplink on both UCS Fabric Interconnects went down. Each Fabric Interconnect has a vPC to the Nexus 500switches. After logging in to the switches, you notice that all vPC member ports on the secondary vPC peer switch are down. The vPC peer keepalive is stilloperational.

What is the problem in this scenario?

A. The vPC peer link is down.

B. Both UCS Fabric Interconnects rebooted.

C. The vPC feature is disabled.

D. A new VLAN was added to the UCS vPC member ports.

Correct Answer: ASection: (none)Explanation

Explanation/Reference:

QUESTION 9An administrator has a FlexPod solution with VMware vSphere. The administrator is migrating all network traffic from standard switches to vSphere distributed

https://www.gratisexam.com/

switches. Virtual machines (VMs) are currently using VM port groups called VLAN_500 and VLAN_501 on standard virtual switch vSwitch3. A new distributed switchcalled dvSwitch_VM is created and new distributed port groups are configured for each VM traffic VLAN. VMs are configured to use the new port groups. After thechange, VMs on VLAN 501 report a loss of network connectivity; however, VMs on VLAN 500 are not showing any connectivity issues. The symptoms areexperienced for VMs on all ESXi hosts.

Which action must the administrator perform to solve the problem?

A. Reboot the virtual machines to re-establish network connectivity.

B. Create a new vmkernel port on dvSwitch_VM for VLAN 501.

C. Configure the dvSwitch_VM port binding to Ephemeral.

D. Add the correct VLAN ID to the new distributed port group for VLAN 501.

Correct Answer: CSection: (none)Explanation

Explanation/Reference:

QUESTION 10Which two database types are supported with the VMWare vCenter 6.0 Server Appliance? (Choose two.)

https://www.gratisexam.com/

A. Oracle

B. vPostgres (embedded)

C. Microsoft SQL Server Express

D. Microsoft SQL Server Enterprise

Correct Answer: ABSection: (none)Explanation

Explanation/Reference:Reference https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_esxi60_n9k.html

https://www.gratisexam.com/

QUESTION 11Which three actions are required to configure two Cisco Nexus switches as vPC peers? (Choose three.)

A. Enable the vPC feature.

B. Configure matching vPC domain IDs.

C. Create a peer link between switches.

D. Configure different vPC domain IDs for each switch.

E. Modify the network QoS policy.

Correct Answer: BCESection: (none)Explanation

Explanation/Reference:

QUESTION 12Click the Exhibit button.

https://www.gratisexam.com/

You have FCoE configured between your Nexus 5672UP switches and UCS Fabric Interconnects running in FC end-host mode. You are experiencing disk I/Oerrors on your VMware FCoE datastore, but the NFS datastores on the same NetApp storage system are not experiencing any problems.

Referring to the Nexus output shown in the exhibit, what would cause this problem?

A. Port flow-control is currently off.

B. The no-drop QoS classes on the Fabric Interconnects are different than those on the Nexus switches.

C. The FCoE uplinks from the Fabric Interconnects must use the ports on the far right side of the Nexus switches.

D. “VL bmap” is hard to set to “off”.

Correct Answer: BSection: (none)Explanation

Explanation/Reference:

https://www.gratisexam.com/

QUESTION 13Click the Exhibit button.

Which Cisco switch is shown in the exhibit?

A. Nexus 2232

B. Nexus 5548

C. Nexus 5596

D. Nexus 7004

Correct Answer: BSection: (none)Explanation

Explanation/Reference:

QUESTION 14Which two technologies must be deployed for a Cisco Nexus 9000 ACI design? (Choose two.)

A. spine switch

B. VSM

C. APIC

D. LACP

Correct Answer: ACSection: (none)

https://www.gratisexam.com/

Explanation

Explanation/Reference:Reference https://www.cisco.com/c/en/us/solutions/collateral/data-center-virtualization/application-centric-infrastructure/white-paper-c11-737909.html

QUESTION 15Your customer has the storage configuration for a FlexPod solution shown below.

--FAS8040 HA-pair--Disk stack one-4x DS4243 disk shelves (2TB SATA disk drives)--Disk stack two- 2x DS 2246 disk shelves (1.2TB disk drives)--There are no unused SAS ports on either controller--There are no expansion slots available on either controller

The customer wants to attach a single DS2246 disk shelf with 800 GB SSD drives.

In this scenario, what are two ways to connect the new shelf for optimal performance? (Choose two).

A. Cable the new shelf to the end of stack one.

B. Cable the new shelf to the end of stack two.

C. Cable a new stack for the SSD shelf.

D. Cable the new shelf to the beginning of stack two.

Correct Answer: CDSection: (none)Explanation

Explanation/Reference:

QUESTION 16Which type of pools do you need to create vHBA templates?

A. MAC

B. WWNN

C. IQN

D. WWPN

Correct Answer: DSection: (none)

https://www.gratisexam.com/

Explanation

Explanation/Reference:Reference https://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/141/UCSM_GUI_Configuration_Guide_141_chapter28.html#task_8F07617D52184F6D93395113FF849DA9

QUESTION 17Click the Exhibit button.

https://www.gratisexam.com/

https://www.gratisexam.com/

An iSCSI SAN boot is not working for a new Cisoc UCS service profile. The new vNIC template was created using the settings shown in the exhibit.

What should you do to make iSCSI SAN boot work?

A. Specify a QoS policy.

B. Change the MAC pool to “<not set>”.

C. Set the iSCSI-A-VLAN as the “Native VLAN”.

D. Change the vNIC template to type “Initial Template”.

Correct Answer: ASection: (none)Explanation

Explanation/Reference:

QUESTION 18Which two operating modes are available with the Nexus 9000 Series switches? (Choose two.)

A. Cisco NX-OS

B. Cisco ACI

C. Cisco IOS

D. Cisco IOS EX

Correct Answer: ABSection: (none)Explanation

Explanation/Reference:Reference https://www.cisco.com/c/en_au/products/switches/nexus-9000-series-switches/index.html

QUESTION 19You installed a new NetApp cluster running clustered Data ONTAP. There is a single Storage Virtual Machine (SVM) named esx1 on the cluster. A volume namedesx_datastore1 is created in the SVM esx1. The name of the root volume for the esx1 SVM is esx1_rootvol. The default export policy was applied to the volumeesx1_rootvol. You verified that the export policy applied to esx_datastore1 contains a single rule that allows all clients to mount the volume as read/write using anyversion of NFS. A Linux client attempts to NFS mount the volume and receives a Permission Denied error.

In this scenario, what caused this error?

https://www.gratisexam.com/

A. NFS has not been configured on the SVM esx1.

B. The volume esx_datastore1 has not been mounted into the namespace of the esx1 SVM.

C. UNIX permissions for the volume esx1_rootvol are not set to read/write.

D. The default export-policy does not have at least one rule to allow all clients read-only access.

Correct Answer: DSection: (none)Explanation

Explanation/Reference:

QUESTION 20Your company is looking for a small remote office infrastructure to deploy to your 30 remote sites. You are asked to write deployment procedures for each site. Yourgoal is to have each site deployed in less than a day.

Which tool will help you accomplish your goal?

https://www.gratisexam.com/

A. OnCommand System Manager

B. OnCommand Insight

C. UCS Director

D. UCS Manager

Correct Answer: CSection: (none)Explanation

Explanation/Reference:

QUESTION 21An administrator has a Flexpod solution configured to use VMware vSphere 6.0. All virtual machines will reside on NAS datastores. Certain critical virtual machineshave a requirement to use eager-zeroed thick provisioning.

https://www.gratisexam.com/

In this scenario, which VMware capability should the administrator enable to satisfy the performance requirement?

A. datastore clustering

B. Storage I/O Control

C. VMware VMFS VAAI

D. NetApp NFS VAAI

Correct Answer: CSection: (none)Explanation

Explanation/Reference:

QUESTION 22You are installing two NetApp FAS8080 EX controllers.Which two ports would you use for HA connectivity? (Choose two.)

A. ib0b

B. ib0a

C. eof

D. e0e

Correct Answer: ABSection: (none)Explanation

Explanation/Reference:Reference https://library.netapp.com/ecm/ecm_download_file/ECMP1610209

QUESTION 23Click the Exhibit button.

https://www.gratisexam.com/

You just finished cabling a UCS 5108 chassis to the Fabric Interconnects.

https://www.gratisexam.com/

Which diagram in the exhibit is cabled correctly according to the CVD guidelines?

A. IV

B. III

C. I

D. II

Correct Answer: ASection: (none)Explanation

Explanation/Reference:

QUESTION 24Click the exhibit button.

https://www.gratisexam.com/

Referring to the exhibit, which two diagrams show the correct way to cable a new NetApp clustered Data ONTAP cluster with two nodes? (Choose two.)

https://www.gratisexam.com/

A. IV

B. II

C. I

D. III

Correct Answer: BDSection: (none)Explanation

Explanation/Reference:

QUESTION 25You are deploying a new virtual machine (VM). Your customer requires that the VM cannot reserve space on the VMFS filesystem, and the VM can only consumeblocks when data is written to disk from and within the VM/Guest OS.

Which virtual disk should you create to meet these requirements?

A. Thick Provision Lazy Zeroed

B. Thin Provision

C. Thick Provision Eager Zeroed

D. Independent Nonpersistent

Correct Answer: BSection: (none)Explanation

Explanation/Reference:Reference https://communities.vmware.com/thread/534974

QUESTION 26You are asked to create an interface group on a NetApp clustered Data ONTAP system. The system is connected to a Cisco Nexus switch in a vPC configurationwith the port-channel mode set to active.

Which NetApp interface group made matches this switch configuration?

A. multimode

B. multimode_lacp

https://www.gratisexam.com/

C. singlemode

D. mode active

Correct Answer: CSection: (none)Explanation

Explanation/Reference:Reference https://library.netapp.com/ecmdocs/ECMP1155586/html/GUID-EFA72201-E035-41E2-AC53-CD81A472B5ED.html

QUESTION 27You run NetApp Config Advisor against you FAS8060A storage system. The report states that the flow control settings for ports e0a on each node are incorrect.

Which set of commands will correct this problem?

A. network interface modify- node netapp-01 –port e0a –flowcontrol –admin nonenetwork interface modify –node netapp-02 –port e0a –flowcontrol – admin none

B. network interface modify- node netapp-01 port e0a-flowcontrol-admin fullnetwork interface modify- node netapp-02 port e0a-flowcontrol-admin full

C. network port modify- node netapp-01 port e0a-flowcontrol-admin nonenetwork port modify- node netapp-02 port e0a-flowcontrol-admin none

D. network port modify- node netapp-01 port e0a-flowcontrol-admin fullnetwork port modify- node netapp-02 port e0a-flowcontrol-admin full

Correct Answer: CSection: (none)Explanation

Explanation/Reference:

QUESTION 28Which management tool is used to configure and monitor centralized policies for multiple Cisco UCS domains?

A. UCS Manager

B. UCS Director

C. UCS Central

D. UCS Performance Manager

https://www.gratisexam.com/

Correct Answer: CSection: (none)Explanation

Explanation/Reference:Reference https://www.cisco.com/c/en/us/products/servers-unified-computing/ucs-central-software/index.html

QUESTION 29An administrator has a FlexPod solution for use with a VMware vSphere 6.0 environment. The virtual environment consists of virtual machines running bothWindows Server 2012 R2 and Windows Server 2008. The administrator determines that the Windows Server 2008 virtual machine VMDKs are misaligned. Theproblem needs to be solved without incurring downtime on the virtual machines.

Which tool enables the administrator to solve the problem without virtual machine downtime?

A. VMware vRealize Operations

B. NetApp mbralign toolkit

C. NetApp Virtual Storage Console

D. UCS Central

Correct Answer: DSection: (none)Explanation

Explanation/Reference:

QUESTION 30You have a NetApp clustered Data ONTAP storage system and vSphere 6 cluster. You discover that VMware VAAI for NFS is not showing as enabled on one of thefive ESXi hosts in your vSphere cluster.

In this scenario, what must you do to enable VAAI for NFS on that ESXi host?

A. Set the DataMover. HardwareAcceleratedInit advanced setting to 0 on the ESXi host.

B. Enable VMware vStorage for NFS on the NetApp SVM.

C. Enable NFSv3 on the storage system.

D. Install the NetApp NFS Plug-in for VMware VAAI on the ESXi host.

Correct Answer: CSection: (none)Explanation

https://www.gratisexam.com/

Explanation/Reference:Reference https://greatwhitetec.com/2014/12/29/deploying-netapp-nfs-plug-in-for-vmware-vaai/

QUESTION 31An administrator just finished installing Windows Server 2012 (Core) with Hyper-V. Now the administrator must deploy a new VM using PowerShell with theparameters shown below.

--Name: web server--Memory: 10 GB--Hard Drive: Existing Disk (d:\vhd\BaseImage.vhdx)

Which PowerShell command creates the VM based on the Information in the scenario?

A. New-VM-Name web server-MemoryStartupbytes 1 GB- VHDPath BaseImage.vhdx

B. New-VM-Name “web server” - MemoryStartupbytes 10 GB- VHDPath d:\vhd\BaseImage.vhdx

C. New-VM-Name “web server”- MemoryStartupbytes 10 GB - VHDPath d:\vhd\BaseImage.vhdx-NewVHDSireBytes 6000000

D. new- VM- Name web server- MemoryStartupBytes 10GB- VHDPath BaseImage.vhdx

Correct Answer: BSection: (none)Explanation

Explanation/Reference:Reference https://technet.microsoft.com/en-us/library/hh846766(v=ws.11).aspx

QUESTION 32You are asked to increase read performance for a single aggregate; however, there are no PCI-e slots available in the NetApp cluster nodes.

In this scenario, which feature meets these requirements?

A. Thin Provisioning

B. Flash Cache

C. Advanced Drive Partitioning

D. Flash pool

Correct Answer: DSection: (none)Explanation

https://www.gratisexam.com/

Explanation/Reference:

QUESTION 33You are an administrator of a UCS system. You notice that when you apply a setting that requires a reboot, the affected hardware reboots immediately withoutwarning. You would like to reboot to be acknowledged by an administrator instead.

What should you do to accomplish this task.

A. Create updating templates.

B. Create a maintenance policy.

C. Create aa BIOS policy.

D. Create a scrub policy.

Correct Answer: DSection: (none)Explanation

Explanation/Reference:

QUESTION 34Click the Exhibit button.

https://www.gratisexam.com/

You have a NetApp cluster and have just performed a storage failover giveback command from the CLI.Referring to the exhibit, what is the status of the storage failover process?

A. The giveback failed because cluster-01 was not able to communicate with the partner’s cluster LIFs.

B. The giveback is partially completed waiting for node cluster-01 to give back the partner’s SFO aggregate.

C. The giveback is partially completed waiting for node cluster-02 to give back the partner’s SFO aggregate.

D. The giveback failed because the partner node was not in a “waiting for “giveback” state.

Correct Answer: CSection: (none)Explanation

Explanation/Reference:

https://www.gratisexam.com/