nsr iocl bottom loading tanker - technical specification
TRANSCRIPT
![Page 1: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/1.jpg)
NSR IOCL Bottom Loading Tanker
![Page 2: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/2.jpg)
Introduction
• We are happy to show you exactly what & where the different components in a bottom loading tanker according to the INDIANOIL Technical Specifications is found.
![Page 3: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/3.jpg)
Bottom Loading API Adaptor ( AL Construction )
![Page 4: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/4.jpg)
Dust Cap (Aluminum)
![Page 5: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/5.jpg)
Air Operated Sequential Vapour Recovery Vent (AL Construction)
![Page 6: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/6.jpg)
Pneumatically Operated Internal Emergency Valve ( AL Construction )
![Page 7: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/7.jpg)
Sump/Mounting Flange ( Mild Steel )
![Page 8: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/8.jpg)
Female Gravity Discharge drop Coupler with hose (API to Camlock)
![Page 9: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/9.jpg)
Vapour Recovery Adaptor Valve ( AL Construction )
![Page 10: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/10.jpg)
Vapour Recovery Adaptor Cap
![Page 11: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/11.jpg)
Vapour Coaming Pipe line
![Page 12: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/12.jpg)
Aluminium Chequered Plate walk way
The tanker is completely sealed on top with aluminium chequered plate to avoid pilferage of material and sparking.
![Page 13: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/13.jpg)
Vapour Dump Vent (AL Construction)
![Page 14: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/14.jpg)
Manhole Assembly (AL Construction)
![Page 15: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/15.jpg)
Pressure / Vacuum Vent on 9 inches emergency hatch
Hatch – Closed Hatch – Open
![Page 16: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/16.jpg)
Vapour hose for vapour vent
![Page 17: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/17.jpg)
Two wire/ Five wire Overfill sensor
![Page 18: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/18.jpg)
Truck Plug/Socket Two wire /Five wire Optic socket with cap
![Page 19: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/19.jpg)
Pneumatic Control Panel
![Page 20: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/20.jpg)
Air interlock valve
![Page 21: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/21.jpg)
Air Filter Regulator
![Page 22: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/22.jpg)
Pressure Switch
![Page 23: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/23.jpg)
Electro pneumatic Shutdown push Button
SWITCH 1 (FRONT) SWITCH 2 ( REAR)
![Page 24: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/24.jpg)
PVC Tubing
PVC Tubing is used for all pneumatic lines in the tanker , an outside protection layer is provided to prevent it from physical damage.
![Page 25: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/25.jpg)
PV Valve ( Top Loading Only )
Please Note :-According to Petroleum and Explosive Safety Organization ( PESO ) department , PV Valve should be used only for top loading tankers and should not be used for bottom loading tankers
![Page 26: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/26.jpg)
Fusible Plug / Vent valve ( Top Loading Only )
Please Note :-According to Petroleum and Explosive Safety Organization ( PESO ) department , Vent Valve should be used only for top loading tankers and should not be used for bottom loading tankers.
![Page 27: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/27.jpg)
Dip Scale
![Page 28: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/28.jpg)
Fire extinguisher
![Page 29: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/29.jpg)
Battery Cut off switch
The cut-off switch is found inside the cabin behind the driver seat , to turn off the vehicle battery when required
![Page 30: NSR IOCL Bottom Loading Tanker - Technical Specification](https://reader036.vdocument.in/reader036/viewer/2022081502/55cb05b9bb61ebb6528b467c/html5/thumbnails/30.jpg)
Thank You
N.S.Rama Rao Body Works Website : www.nsrrbw.comEmail : [email protected] : 044-22770008Fax : 044-22770071