Page 1: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

#vmworld

CNET1474BU

NSX and Cisco ACI:Running Your SDDCon a Cisco Underlay

Paul Mancuso, VMware, Inc.

#CNET1474BU

VMworld 2019 Content: Not for publication or distribution

Page 2: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc.

Disclaimer

This presentation may contain product features or functionality that are currently under development.

This overview of new technology represents no commitment from VMware to deliver these features in any generally available product.

Features are subject to change, and must not be included in contracts, purchase orders, or sales agreements of any kind.

Technical feasibility and market demand will affect final delivery.

Pricing and packaging for any new features/functionality/technology discussed or presented, have not been determined.

2

The information in this presentation is for informational purposes only and may not be incorporated into any contract. There is no commitment or obligation to deliver any items presented herein. VMworld 2019 Content: Not for publication or distribution

Page 3: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

3©2019 VMware, Inc.

VMware NSX Data Center has proven its ability for deployment on any switch fabric. Customers have asked for simplification of application deployment on a Cisco infrastructure. VMware developed architectural guides for deploying an NSX Data Center platform on Cisco’s switching fabrics, including a Cisco ACI underlay. In this session, you will learn best practices for implementing a software-defined data center on any Cisco underlay. You will find out what is the required to set up Cisco ACI and steps to normalize ACI’s fabric for an NSX Data Center for VMware vSphere or VMware NSX-T Data Center deployment.

Session Objective

VMworld 2019 Content: Not for publication or distribution

Page 4: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 4

vSphere

BRANCH

BRANCH

EDGE/IOT

TELCO/NFV

BRANCH

BRANCH

DCDC

DC

BRANCH

Virtual Cloud Network

Tied Together—Everywhere.

vRNI

CLEAR VISIBILITY

NSX Intelligence

DEEP INSIGHT

VMworld 2019 Content: Not for publication or distribution

Page 5: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc.

Agenda

5

AgendaNSX over Any Underlay Role of Physical and Virtual Network Infrastructure

Design PrimerNSX Data Center and Cisco ACI overview and terms

NSX Data Center on an ACI InfrastructureDesign guide discussion

OperationsHow a good design reduces the pitfalls

Summary

VMworld 2019 Content: Not for publication or distribution

Page 6: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 6

Extract Simplicityvs Abstracting

Complexity

VMworld 2019 Content: Not for publication or distribution

Page 7: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

7©2019 VMware, Inc.

VMware NSX over Any UnderlayThe role of physical and virtual network infrastructure

VMworld 2019 Content: Not for publication or distribution

Page 8: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 8

Virtual Network Infrastructure:Optimized for Application Scale, IT Operations and Efficiency

Built to meet the needs of specific infrastructure

environments (DC, Campus, Branch)

Physical Network Infrastructure: Optimized for price, throughput, latency

Built to meet the needs of applications and data across the end-to-end IT delivery model (DC, Cloud, Edge)

Productivity

Line

VMworld 2019 Content: Not for publication or distribution

Page 9: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 9

NSXSecurity, Overlay, Services

NSX and Cisco underlay interoperability

NSX Data Center over Any Underlay

• Consistent API for networking, security cross cloud

• Works with any underlay

NSX provides:

• Fabric management

• Programmable physical network

Switch fabric provides:

ACI Switch Fabric

VMworld 2019 Content: Not for publication or distribution

Page 10: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 10

High speed scalable security platform

Context aware andLayer 7 FW capabilities

Supports and extends life of the switch fabric

Supported management infrastructure

Built-in vs. Bolt-on:

NSX is the only native networking and security platform for ESXi.

ESXi w/NSX

Service InsertionDistributed Firewall Networking

vCenter

Supported

High Performance

Operational Simplicity

Native Service Platform

Agile Network Deployment

Stable, high speed network infrastructure

++

Consistent networking and security built-in

Ubiquitous policy platform data center and cloud

Bare Metal Workload

VMworld 2019 Content: Not for publication or distribution

Page 11: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 11

Intrinsic Security

Building the de-facto firewall used within the data center

• Unique, ubiquitous enforcement

• Distributed for cloud-scale

• Advanced security features

• Zone firewalling requirements and distributed firewalling requirements

• Analytics and visualization

Realtime Visibility

Net-sec Analytics

Zone Firewalling

Data Center Branch VMC Cloud

Unified Management Plane

Layer 4-7

Edge Appliance

URL Classification

NEW

Layer 4-7

Identity Firewalling

URL Whitelisting

Endpoint ProtectionBare-metalVMs Public Clouds,

AWS, AzureContainers

Micro-segmentation

VMC on AWSVMworld 2019 Content: Not for publication or distribution

Page 12: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

12©2019 VMware, Inc.

Design PrimerNSX-T Architecture Overview and Value

VMworld 2019 Content: Not for publication or distribution

Page 13: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 13

NSX-T Datacenter Components

Converged management & control plane cluster

3 node cluster for scale & high availability

UI/API for interacting with user, automation & CMP platforms

Validates and Stores desired configuration

Maintain and propagate dynamic state

Management, control and data planes

Cloud Service Manager

NSX Container Plug-in

vCenter(s)

VMs Containers

ESXi host KVM host

Bare-MetalServer

NSXEdge

NSXCloudGW

WindowsVM

LinuxVM

PrivateCloud

PublicCloud

N-VDS N-VDS NSX

NSX NSX

Management/control plane

Data plane

NSX Management Cluster

GUI/REST/CMPConsumption

PhysicalNetwork

Management/control plane

Host workloads (VMs, containers) and services

Implements distributed routingand firewalling

Distributed data plane

VMworld 2019 Content: Not for publication or distribution

Page 14: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 14

Bare-metalVMs VMwareCloud

Public Cloud

PhysicalSwitching OutpostsContainers

TelcoCloud

Network Infrastructure as Code

Ops. Simple. Consistent.

Intrinsic SecurityCloud-ScalePlatform

The industry’s first & only network & security platform running today where your apps are

Networking and Security for the Multi-Cloud Era

VM, container, physical, private, public

VMworld 2019 Content: Not for publication or distribution

Page 15: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

15©2019 VMware, Inc.

NSX Data Center Deploymenton Standard Cisco InfrastructureNexus NX-OS switches and Cisco UCS

VMworld 2019 Content: Not for publication or distribution

Page 16: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 16

Standard NSX data center infrastructure topology

NSX Data Center Design Overview

Physical Network

Compute Clusters Edge Cluster(s) Management Cluster

Application

Transport Subnet /22

NSX Edge Nodes

VM1

Management(VLAN)

Database

Transit VLAN

Web

TieredLogical Switches

Transport Zone

VM5

VM2

VM3

VM5 VM6

PrototypicalDesign

NSX Manager Cluster

CCP

VMworld 2019 Content: Not for publication or distribution

Page 17: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 17

NSX over NX-OS: Overview

ACI Infrastructure

Supports attachment of hosts

• Define physical domain of host attachment

• VLANs, switch interfaces, and policies in use

• Domains, physical and external

Create application profile

• Defines EPGs

• Networks

– Private networks

– Bridge domains

– External L2 and L3 connectivity

NSX Overlay

Compute

VMKernel

ACLs

VLANs

NX-OS Fabric

Compute Edge

VM1 VM3 VM5 VM2 VM4 VM6

Web LS

APP LS

DB LS

PeeringVLANs

Mgmt vMotion Storage Transport

Management

Border Leaves

Transit VLAN

TransitVLAN

VMworld 2019 Content: Not for publication or distribution

Page 18: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 18

NSX Data Center Infrastructure Independence

NSX

Any L2/L3 Data Center Interconnect

Pod A Pod BL2

L3

L3 Core L3 Core

Traditional Data Center Fabrics NSX Platform Proprietary Data Center Fabrics

ACI

ACI

ACI ACI ACI

ACIVMworld 2019 Content: Not for publication or distribution

Page 19: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 19

NSX Data Center Design on Cisco L2 and L3 Topologies

Pod components can be any mix of 9k / 7k/ 6k / 5k / 2k

95xx

VXLAN VLAN ID 103 - Transport Zone Scope (extends across ALL PODs/clusters)

POD A

ComputeCluster A

ComputeCluster B

95xx

93xx 93xx

95xx

93xx 93xx

L3

L2

VLAN ID 100, 101 and 102 Scope

UCS B-Series

POD B

95xx

93xx 93xx

95xx

93xx 93xx

L3

L2

VLAN ID 100, 101 and 102 Scope

UCS B-Series

95xx

L3 Core

95xx

VXLAN VLAN ID 103 - Transport Zone Scope (extends across ALL PODs/clusters)

POD A

ComputeCluster A

ComputeCluster B

95xx

93xx 93xx

95xx

93xx 93xx

L3

L2

VLAN ID 100, 101 and 102 Scope

UCS B-Series

POD B

95xx

93xx 93xx

95xx

93xx 93xx

L3

L2

VLAN ID 200, 201 and 202 Scope

UCS B-Series

95xx

L3 Core

VMworld 2019 Content: Not for publication or distribution

Page 20: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 20

Cisco DC Topologies – VXLAN

VLAN ID 100, 101 and 102 Scope – VXLAN VLAN ID 103 - Transport Zone Scope (extends across ALL PODs/clusters)

Compute Cluster A

Compute Cluster B

UCS B-Series UCS B-Series

Spine

Leaf

UCS B-Series UCS B-Series

Border Leaf

Mgt / Edge Cluster

VLANs & IP Subnet Defined at each ToR

SVI Interface VLAN ID IP Subnet

Management 100 10.100.100.x/24

vMotion 101 10.101.101.x/24

Storage 102 10.102.102.x/24

VXLAN 103 10.103.103.x/24

L3 Spine DC CoreInternet/DMZ

56xx 56xx

Spine - Leaf can be:9xxx, 7xxx, 6xxx ,

56xx

Cisco’s Prime or DCNM may also provide underlay and

VXLAN management.

95xx 95xx 95xx 95xx

60xx 60xx93xx 93xx93xx 93xx

VMworld 2019 Content: Not for publication or distribution

Page 21: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 21

UCS Fabric Interconnects• Run in End-Host mode

• vPC connectivity to Nexus switching

vSphere Compute connectivity• UCS vnics can be shared or dedicated

• vSphere dvUplinks equals number of vmnics

• Use multiple VTEPs with Src ID teaming

• 1:1 mapping of VTEPs to UCS vnics

vSphere Edge connectivity• Edge Cluster preferably UCS C-Series

• Separate straight thru connection, bypass FIs

• More to follow for UCS B-Series

vSphere Host and UCS Interconnectivity

NSX Data Center and UCS Connectivity

UCS

Edge Leaf

L3

L2

Edge ClusterUCS C-Series

DC CoreInternet/DMZ

DC Fabric

95xx 95xx

93xx 93xx

VPN VPN

VPN VPN

VMworld 2019 Content: Not for publication or distribution

Page 22: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 22

vDS Design, Uplink and Traffic Flow

Cisco UCS Connectivity

VMNIC 0 VMNIC 1 VMNIC 2 VMNIC 3

vNIC 3vNIC 1

2204 FEX2204 FEX

6248 (A) 6248 (B)

Teaming Mode

VMkernelVXLAN

VTEP – 1

Traffic Type

VMkernelVXLAN

VTEP - 2

VMkernel vMotion

VMkernelMgmt

VMkernel IP

Storage

LBT SRC_ID SRC_ID Explicit FailoverLBT

Nexus 93XXNX-OS Mode

vNIC 4vNIC 2

VDS – 2 Routing

Routing VLAN PG

20

BridgingPG

Routing VLAN PG

10

VDS - 1 MGMT, vMotion, NFS, VXLAN & Bridging

Recommended UCS B-Series setup

SRC_ID SRC_ID SRC_ID

UCSB-SeriesBlade

93xx 93xx

VMworld 2019 Content: Not for publication or distribution

Page 23: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 23

UCS vNIC Connectivity NSX Data Center

3 UCS Service Profiles

UCS Management Service Profile Template

• 2 UCS vNICS (Optional 4 vNIC)

• All Traffic East / West(Optional Management to be routed outside of fabric)

• VLAN Pinning for all VLANs to vPCports (Separates Edge VLANs)

UCS Compute Service Profile Template

• 2 UCS vNICs

• All Traffic East / West

• VLAN Pinning for all VLANs to vPCports

vDS dvPortgroups for Compute Nodes (NSX Data Center for vSphere)

VMNIC 0 VMNIC 1

vNIC 1

23xx FEX23xx FEX

63xx (A) 63xx (B)

Teaming Mode

Overlay TEP – 1

Traffic Type

Overlay TEP - 2

vMotion MgmtIP Storage

LBT SRC_ID SRC_ID Failover

LBT

Nexus 93XXNX-OS Mode

vNIC 2

VDS or NVDS - 1 MGMT, vMotion, vSAN, NSX Overlay

Recommended UCS B-Series setup

UCSB-SeriesBlade

93xx 93xx

vNIC 1 vNIC 2

ESXi Infra

VMNIC0 VMNIC1

Vnic 3 vNIC 4

NVDS-1

VMNIC2 VMNIC3

2 vDS Model1 vDS + 1 NVDS

VMworld 2019 Content: Not for publication or distribution

Page 24: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 24

Cisco UCS Network Uplink Recommendations

VLAN Pinning– Edge Node VLANs

Two sets of VLANs on separate port-channels (PC and vPC)

• Soft-Pinning

vSphere/NSX Infrastructure

• East – West vPC

NSX Edge Nodes

• North – South PC

Deterministic traffic

• Avoid using complex traffic patterns for routed traffic.

• Easy alignment of adjacencies

UCS B-Series – Use ‘Soft Pinning’ for Layer-2 Uplinks

Nexus 93XX LeavesNX-OS / ACI Mode

(No Leaf channel in ACI Mode)

Dedicated Port-ChannelNorth – South

VLANs

23xx FEX23xx FEX

63xx (A) 63xx (B)

93xx 93xx

UCS Fabric Interconnects andUCS B-Series Chassis FEX

Virtual Port-ChannelEast – West

VLANs

VLAN PinningEdge Node VLANs

Source: Cisco UCS Network Mgmt Guide 4.0Chapter: Upstream Soft Pinning Layer 2 UpstreamVMworld 2019 Content: Not for publication or distribution

Page 25: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 25

vDS

NSX Edge Node Connectivity

NSX Edge Node

• 4 vNIC design *

• One-to-one alignment of edge node vnics with vSphere dvPg

Soft pinning and UCS vNIC Profile

• East / West vNICs

– Mgmt (Failover A/S)

– Transport (Src ID A/A)

• Edge Node Routing vNIC (1 Per FI)

– Active / Unused per side

vSphere dv-Portgroups

• VLAN tagged for external alignment

Edge Node vnics

• No VLAN tagged required

UCS B Series reference configuration

Mgmt NVDS-1 NVDS-2 NVDS-3

vNIC 3vNIC 1

UCS vNICsESXi vmnic

Mgmt Pg

ESXi Edge Cluster Host

NSX Edge Node

vNIC 2

Transport Pg

23xx FEX

63xx (B)

23xx FEX

63xx (B)

vNIC 4

Ext–Pg–FI-A Pg Ext–Pg–FI-B Pg

Optional: One or twovSphere VDS

*UCS B Series 4 vNICs / UCS C-Series 4 NICsVMworld 2019 Content: Not for publication or distribution

Page 26: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

26©2019 VMware, Inc.

NSX Data Center on a Cisco ACI UnderlayDesign and deployment discussion

VMworld 2019 Content: Not for publication or distribution

Page 27: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 27

ACI infrastructure terminology

ACI Fabric Object Alignment

Switch and leaf profile

• Interface profile

– Interface selector

– Port range

– Interface Policy Group

AEP

• Selectors for attachment points

– Ports, PC, vPC

• Associated using Interface Port Policy Group object

• Associated to domain(s)

– Links VLAN Range

Leaf Ports +

Policies

AEP

Domains (Phy, L2, L3)

• Specifies how devices are connected to the fabric

• Virtual, bare metal, external L2 or external L3

VLAN pools

• Identifies the VLAN IDs used for encapsulation between the ACI fabric and system devices

• Pools are associated to domain

Physical Domain

External Domain

VLAN Pool 1

VLAN Pool 2

VLAN Pool 3

VMworld 2019 Content: Not for publication or distribution

Page 28: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 28

BD

Terminology: Application profile, network and external domain objects

ACI Tenant Overview

Consume Consume Consume

L3 / VRF

Shared Infrastructure ServicesDNS, Syslog, AD, etc

L3OutEPG

WebEPG

L3OutPublic

BDSubnet2

BDSubnet3

APPEPG

DBEPG

Tenant X

CommonTenant

Provide Provide Provide

Subnet1

ProvideConsume

Contract

Web Contract

ProvideConsume

Contract

App Contract

ProvideConsume

contract

DB Contract

VMworld 2019 Content: Not for publication or distribution

Page 29: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 29

Streamline ACI Ops – NSX Data Center on ACI Underlay

Pools VLAN, VXLAN

VMM Dom1

VMM Dom1

VMM Dom1

Phy Ext Dom

AAEP Policy

AAEP Policy

AAEP Policy

IntfPoliciy

Grp

IntfPolicyGrp

IntfPolicyGrp

IntfPolicyGrp

IntfPolicy

Settings

IntfPolicy

Settings

IntfPolicy

Settings

IntfPolicy

Settings

Pools VLAN, VXLAN

Intf Port Selector

Intf Port Selector

Intf Port Selector

Intf Port Selector

IntfProfile

IntfProfile

IntfProfile

IntfProfile

Switch Profile

Switch Profile

Switch Profile

Switch Profile

Switch Selector

Switch Selector

Switch Selector

Switch Selector

SwPolicy Group

SwPolicy Group

SwPolicy Group

SwPolicy Group

Multiple per site fabric, multiple tenant policies plus ACI Multi-site policy manager settings = MTTR

Multiple fabric policies of various complexity

Single set of fabric policies Single ACI Tenant PolicyNSX Data Center on ACI underlay

NSX Data Center on any underlay

= +

AAEP Policy

Tenant – A

Multiple AP, BD,VRFs, L3outs

Tenant – B

Multiple AP, BD,VRFs, L3outs

Tenant – C

Multiple AP, BD,VRFs, L3outs

Tenant – D

Multiple AP, BD,VRFs, L3outs

Multiple ACI tenant policies of various complexity

VMworld 2019 Content: Not for publication or distribution

Page 30: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 30

NSX over NX-OS: Overview

ACI Infrastructure

Supports attachment of hosts

• Define physical domain of host attachment

• VLANs, switch interfaces, and policies in use

• Domains, physical and external

Create application profile

• Defines EPGs

• Networks

– Private networks

– Bridge domains

– External L2 and L3 connectivity

NSX Overlay

Compute

VMKernel

ACLs

VLANs

NX-OS Fabric

Compute Edge

VM1 VM3 VM5 VM2 VM4 VM6

Web LS

APP LS

DB LS

PeeringVLANs

Mgmt vMotion Storage Transport

Management

Border Leaves

Transit VLAN

TransitVLAN

VMworld 2019 Content: Not for publication or distribution

Page 31: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 31

ACI infrastructure requirements

NSX over ACI: Overview

ACI Infrastructure

Supports attachment of hosts

• Define physical domain of host attachment

• VLANs, switch interfaces, and policies in use

• Domains, physical and external

Create Application Profile

• Defines EPGs

• Networks

– Private networks

– Bridge domains

– External L2 and L3 connectivity

NSX Overlay

Compute

VMKernel

ACI Contracts

ACI EPGs

Layer 2ACI Fabric

Compute Edge

VM1 VM3 VM5 VM2 VM4 VM6

Web LS

APP LS

DB LS

PeeringVLANs

Mgmt vMotion Storage Transport

Management

Border Leaves

Transit EPG

TransitEPG

VMworld 2019 Content: Not for publication or distribution

Page 32: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 32

NSX over ACI DeploymentInfrastructure design

ACI Fabric IdealsFabric Policies

Fabric Access PoliciesNSX over ACI

Tenant Configuration

Fabric PoliciesFabric Access Policies

Overall infrastructure design for a supported NSX data center deployment on an ACI underlay

Layer 2 fabric logistics:

• Single tenant

• Fewer contract needs

• Map static vSphere Eps

• Map NSX Edge to ACI border

Minimum requirements:

• 1 Physical domain

• 1 External routing domain

• 2 VLAN pools (Int & Ext)

• 1 AEP (Leaf & switch policies, Int & Int sel policies, etc..)

NSX data center deployment

• Separate tenant (not common)

• 1 Application (network) profile

• 4 EPGs (base EPGs)

• 4 bridge domains, 1 VRF(ea VLAN = ea EPG = ea BD)L3Out; South (NSX Overlay)

VMworld 2019 Content: Not for publication or distribution

Page 33: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 34

Fabric and fabric access policies required of ACI

Creating the Fabric Policies

This small set of policies are

required of any ACI deployment.

VMware NSX over ACI underlay design requires a

substantially smaller subset of these fabric

required objects

Create a single set of fabric abstractions

NSX-Phy-Domain

NSX-Infra VLAN Pool

NSX-L3-Domain

NSX-Ext VLAN Pool

NSX-AEP(AEP)

NSX-Host-Int-Profile(Leaf Interface Profile)

NSX-Host-Ports(Access Port Selector)

NSX-Port-Policy Group(Interface Policy Group)

Interface Policies

NSX-Leaf-Profile(Leaf Profile)

NSX-Leaf-Sel(Leaf Selector)

NSX-Sw-Pol-Group(Leaf Policy Group)

Leaf Policies

LLDP CDP Default

DomainsAttachable Access

Entity Profile Interface Policies Switch Policies

Where How Interface Settings Switch Settings

VMworld 2019 Content: Not for publication or distribution

Page 34: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 35

Reducing the complexity and increasing operational simplicity

NSX on ACI Tenant

TenantCommon Shared Infrastructure Services

DNS, Syslog, AD, etc.

Provide

Consume

Optional: Place either in common tenant or within NSX on ACI tenant.

TenantNSX on ACI

Management EPG

Shared Infrastructure ServicesDNS, Syslog, AD, etc.

vMotionEPG

IP StorageEPG

OverlayEPG

Routed External

L3 Out EPG

L3 OutvMotion

BDIPSBD

OverlayBD

ManagementBD

vMotionSubnet

IP StorageSubnet

OverlaySubnet

L3 / VRF

PublicManagement

Subnet

VMworld 2019 Content: Not for publication or distribution

Page 35: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 36

NSX on ACI Tenant Overview

Single ACI Tenant

• Adds simplicity to fabric mgmt.

• Reduces dynamic management of ACI fabric

• Adds stability

NSX Edge

• Application Platform disaggregated from physical

Single Tenant for all application workloads

• NSX on ACI Application Profile

• Four EPGs

• Statically or App EPG to AEP

• NSX on ACI Networking

• Bridge Domains (one)

• VRF (single)

• NSX on ACI External Networking

• L3Out and EEPG

• DC connect

• NSX OverlayVMworld 2019 Content: Not for publication or distribution

Page 36: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 37

NSX on ACI L3Out Detail

NSX External connectivity

• ECMP or HA

• ACI setup the same

• Simplicity to L3Out

• NSX Overlay: Stub network

• Requires only a default route

• Simplicity to L3Out

• NSX Edge Cluster

• Role: Provider edge

• NSX T1 routers

• Role: Tenant routers

• Routing External Domain

• Node Profiles (Border leaves)BGP Peers using SVIs

• Configured Node Profiles

• Displays BGP Neighbors

• L3Out Networks (EEPG)

• Default Route Leak PolicyVMworld 2019 Content: Not for publication or distribution

Page 37: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 38

Connecting the NSX overlay to the switch fabric

NSX Edge Routing – NSX on ACI Underlay

Edge Cluster provides E/W and N/S connectivity

• Standard ACI physical domainfor E/W

– 4 Infrastructure EPGs

• Routed external domain for N/S

• The same or separate physical uplinks can be used

• 2 or 4 pNIC (4 vNIC UCS) design

• Best to utilize separate fabric access and pool policy objects: VLAN pools, Domains, PC, Interface leaf and switch policy objects

Edge Cluster

Same physical uplinks used for East/West and North/South

ACI

ACI

ACI

ACI ACI ACI

VMworld 2019 Content: Not for publication or distribution

Page 38: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 39

Example Physical and Logical Connectivity

NSX Edge to ACI SVI Peer Connectivity

Interface SVIsVLAN Red

Interface SVIsVLAN Blue

ECMPEdges

Pair of SVIs per Border Leaf One SVI per each VLAN Interface

2x Peer Connections per Edge Node = 1x Peer per VLAN, per NSX Edge

Transit VLANs

Peer Connectivity

ACIBorderLeaves

VMworld 2019 Content: Not for publication or distribution

Page 39: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

40©2019 VMware, Inc.

OperationsA good design reduces the risks

VMworld 2019 Content: Not for publication or distribution

Page 40: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 41

VMware NSX data center design on an ACI underlay

Leverage Operational Value

Operational features and scaling are inherent and easily manageable

• Infrastructure traffic inherently isolated

• Infrastructure traffic scales within the fabric

• Minimal need for infrastructure changes

• Increasing workload deployment within the NSX Overlay requires no changes to physical underlay

• Scaling infrastructure has minimal overhead

• Reduced HW replacement

• Hardware infrastructure stabilized

Isolation of Infrastructure Traffic

Application deployment scalability

Infrastructure operations are minimized

VMworld 2019 Content: Not for publication or distribution

Page 41: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 42

Leveraging operational simplicity

Infrastructure Traffic Isolation

NSX data center infrastructure traffic

• Provides a high speed scalable fabric

• Traffic types can be inherently isolated by ACI EPGs

• vSphere provides inherent Advanced Security for VMKernel traffic

• No necessity to manage isolation

• Simplifies underlay operations

Management Group

VLAN 100

Transport Group

VLAN 100

Management Group

VLAN 100

TransportGroup

VLAN 100

Permit Access No Access

ACI ACI

ACI ACI ACI ACI

VMworld 2019 Content: Not for publication or distribution

Page 42: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 43

Scale and deploy applications abstracted from switch fabric

NSX Logical Routing Enhancements

NSX Edge cluster advantage

• Application decoupled from physical fabric

• Homogenous policy operation

- Multi-Site, Multi-Cloud, Heterogenous switch fabrics

• Agile distributed services deployment

- LB, NAT, Tenant FW, DNS, DHCP,etc

• Micro-segmentation completeness

- Logical overlay separation

- Stateful distributed FW

- Context aware micro-segmentation

- Layer-7 guest and network service insertion

ACI Leaves

Edge Cluster ECMP Routing

ACI Switch Fabric

VLAN: 700 10.0.100.0/24

Physical-to Virtual On/Off Ramp

Virtual workload flow may stay local on the host if source and destination are the same host

VNI: 5003192.168.102.0/24

VNI: 5002192.168.101.0/24

VNI: 5001192.168.100.0/24

Logical Network

Distributed Routing

VMworld 2019 Content: Not for publication or distribution

Page 43: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 44

Infrastructure operations minimized

Software Defined Data Center

Deployed application

view

Stable, scalable

hardware underlay

Software defined

managed network

Two fabric access policies

required to scale out

Leaf and Interface selector policies

Web2Web1 App2App1

Logical Switch 1 Logical Switch 2

Spine

Physical Topology

Logical Router

Software defined logical application topology

HV1

HV1

HV3

Web1

App2

App1 HV4

HV5

HV6 Web2

Edge

HV7

HV8

Edge

HV10

HV11

Logical routers on every hypervisor

(in kernel)

(ESXi / KVM) Infrastructure ClustersVMworld 2019 Content: Not for publication or distribution

Page 44: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 45

NSX Transport and Edge Performance

Methodology:• iPerf 2.0.5

− 4 Threads per VM Pair

− 4 – 12 VM Pairs

• Average Throughput – 35 Gbps @ 1500 MTU

• E/W (With Firewall)– Logical Switch

– Logical Router

• N/S– Routing

– Routing with Firewall

– SNAT

– DNAT

East/west and north/south high performance capability

NSX-T Data Center Performance Deep Dive [NET1855BU]VMworld 2018 Live Demonstration

Throughput - NSX Data Center 2.2Using Intel® XL710s (40Gbps) – iPerf 2

Th

rou

gh

pu

t (G

bp

s)

SNAT DNAT

NAT

Overlay > VLAN

LS

Overlay > VLANVLAN> Overlay VLAN> Overlay

LR (T1) LR (T0) NS Routing NS Routing + Firewall

40

35

30

25

20

15

10

5

0

VMworld 2019 Content: Not for publication or distribution

Page 45: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 46

Wireshark caption of NSX overlay traffic in ACI iVXLAN fabric

Visibility of Encapsulated Traffic in ACI Fabric

VMworld 2019 Content: Not for publication or distribution

Page 46: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 47

Accelerate application security and networking across private, public and hybrid clouds

VMware Network Insight

• Accelerate micro-segmentation deployment

• Troubleshoot security for SDDC, native AWS and hybrid applications

• Minimize business risk during application migration

• Reduce mean time to resolution for application connectivity issues

• Optimize application performance by eliminating network bottlenecks

• Audit network and security changes over time

• Scale across multiple NSX managers

• Boost uptime by proactively detecting misconfiguration errors

• Ensure compliance for NSX

Use Cases

Plan application security and migration

Optimize and troubleshoot virtual and physical networks

Manage and scale NSX

VMworld 2019 Content: Not for publication or distribution

Page 47: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 48

Complete virtual through physical visibility!

vRealize Network Insight: NSX Overlay on ACI Switch Fabric

vRNI for ACI Fabrics

Features include:

• ACI/APIC integration

• EPG, bridge domain, ANP, EPG to VM, EPG to DVPG association

• Layer 2 path from VM to Leaf nodes

• VM to VM path visibility I(ACI VRF in VM-VM path)

• ACI Leaf nodes and their ports in path through Spine (ACI fabric)

VMworld 2019 Content: Not for publication or distribution

Page 48: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

49©2019 VMware, Inc.

Jesse RyskiAAA/ACG

Fiat Chrysler Automotive

• ACI Multi-Pod Deployment 70+ Leaves

AAA/ACG

• Greenfield COLO ACI as Underlay For NSX

• Brownfield 7,5,2+ Vcenter Migration to ACI/NSX

I’m a NSX Ninja

VMworld 2019 Content: Not for publication or distribution

Page 49: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

50©2019 VMware, Inc.

Use Case – Secure PCI Data Deploy New Application• Consistent Repetitive infrastructure model irrelevant to application being

deployed

• Micro-segmentation For new app

• Reduce DC footprint

• Visibility into physical layer underlay packet flow

• Prepare future NSX Micro-segmentation in Existing Brownfield DC

• Prepare for automation

• Prepare Containerization

VMworld 2019 Content: Not for publication or distribution

Page 50: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

51©2019 VMware, Inc.

ACI as Underlay For NSX• Spine Leaf Model scales easily for NSX

• Predictable Latency

• Scalable

• High Bandwidth

• Management

• Centralized Configuration

• Rapid deployment\expansion

• Rapid Transfer of Encapsulated Traffic

• Agnostic to overlay traffic

• Forwarding encapsulated traffic efficiently

• Security

• Bare metal micro-seg

• Default Deny

• Strategic Partners

• Supported Model

• Day 2 SupportVMworld 2019 Content: Not for publication or distribution

Page 51: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

52©2019 VMware, Inc.

NSX As overlay

• Underlay agnostic

• HardWare Lifecycle Management

• Strategic Direction

• East West Traffic

• Opportunistic Local Host switching and routing

• Underlay simplistic switching and routing requirements

• Secured by NSX micro segmentation

• Reduced overhead

• Existing Vcenter

• Largely Virtualized in Primary DC (60%-70%)

• New Green-Field 99% virtual

• Highly virtualized future

• Net New Apps Deployed NSX micro-segmentation

• Refresh into Virtual

• Slowly Re-platformVMworld 2019 Content: Not for publication or distribution

Page 52: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

©2019 VMware, Inc. 53

ResourcesHow to get started

Design Guides Demos

Take a Hands-on Lab Join VMUG, VMware Communities (VMTN)

LEARN TRY

nsx.techzone.vmware.com

CONNECTTRY

@VMwareNSX#runNSXVMworld 2019 Content: Not for publication or distribution

Page 53: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

VMworld 2019 Content: Not for publication or distribution

Page 54: NSX and Cisco ACI: Running Your SDDC on a Cisco Underlaydl.geekboy.pro:8080/VMworld 2019/CNET1474BU.pdf · Running Your SDDC on a Cisco Underlay Paul Mancuso, VMware, Inc. VMworld

VMworld 2019 Content: Not for publication or distribution