n_tof commissioning intc-p-249 spokespersons: j.l.tain, v.vlachoudis contactperson: v.vlachoudis...

Download N_TOF commissioning INTC-P-249 Spokespersons: J.L.Tain, V.Vlachoudis Contactperson: V.Vlachoudis 16-17 th Nov 2009 for the n_TOF collaboration

If you can't read please download the document

Upload: lee-imogene-bates

Post on 17-Jan-2018

224 views

Category:

Documents


0 download

DESCRIPTION

Proposed measurements 1.Neutron fluence 2.Neutron beam profile 3.Neutron energy resolution function 4.Neutron energy versus time-of-flight relation 5.Scattered in-beam  -ray background 6.Scattered neutron background 7.Off-beam background Needed to obtain cross sections The neutronics of the new target is different, therefore there is a need to characterize carefully the beam and backgrounds in order to fulfill our goal of obtaining accurate data: Needed to control systematic errors Detected counts as a function of ToF Cross section as a function of energy

TRANSCRIPT

n_TOF commissioning INTC-P-249 Spokespersons: J.L.Tain, V.Vlachoudis Contactperson: V.Vlachoudis th Nov 2009 for the n_TOF collaboration o Pb mono-block ( 60cm L40cm) o Forced water cooling o Chemically controlled water o Oxygen/Corrosion control o Separate moderator from cooling o Al container o 3 Al-windows with air-gap o Defocused proton beam o New Ventilation system o Air-tight primary zone with a 40Pa depression New Target Refurbished Facility Proposed measurements 1.Neutron fluence 2.Neutron beam profile 3.Neutron energy resolution function 4.Neutron energy versus time-of-flight relation 5.Scattered in-beam -ray background 6.Scattered neutron background 7.Off-beam background Needed to obtain cross sections The neutronics of the new target is different, therefore there is a need to characterize carefully the beam and backgrounds in order to fulfill our goal of obtaining accurate data: Needed to control systematic errors Detected counts as a function of ToF Cross section as a function of energy 1.General start-up:1.0 p 2.Neutron fluence: (*)1.6 p 3.Beam profile:- 4.Resolution Function: (*)5.0 p 5.In-beam -ray background: (*)4.0 p 6.Scattered n background:2.1 p 7.Off-beam background:- Total: 2.45 p (*) assuming: normal water / borated water Requested beam time Proposed Experimental Apparatus Beam characteristics: Neutron fluence: PTB Fission Chamber 235 U, 238 U FIC 235 U, 238 U uMegas: 235 U & 10 B SiLi, Gold foils Spatial distribution: Medipix with LiF & polyethylene X-Y Megas with 10 B Resolution function: C6D6 with 54,56 Fe, 32 S Background: CR-39, TLD, BaF 2 and C6D6 Cooling station: Monitor Performance Control O 2 level PTB FC X uMegas Quad Medipix C6D6 TAC Scheduled beam on n_TOF target Delayed due to PS problems Medipix run. Problem on readout of the beam transformer. No reliable proton information X-Y Megas Beam profile measurements Alignment issues with the detectors Possible alignment problem on 2 nd collimator Beam transformer readout problem solved Resolution function Fluence measurements with PTB chamber Fe/Ni proposal Scattered neutron background in TAC Experimental alignment of the second collimator Commissioning Diary Experimental Area Beam profile results 8 Comparison X-Y Micromegas data vs. simulation for the New Target Projection of a cut around the mean value of the 2D distribution of X and Y +/- 2.5 mm in simulated data +/- 2.8 mm for X-Y Micromegas data S-Ex position m Full coverage from thermal to 1 MeV The direct comparison with data from 2002 do not indicate a significant change in the Resolution Function. The detailed analysis from high energy 56 Fe resonances and simulations remains to be done. Use 2 C6D6 detectors 2g samples enriched 54 Fe, 56 Fe Also 32 S (513, 819keV) Expected: 10 3 counts in weakest resonance 25% worsen on the tail. Effect to be seen after resonance analysis with SAMMY The C6D6 were placed upstream to reduce the in-beam gamma background Statistics were lower Resolution Function Neutron Fluence measurements The shape and intensity of the neutron fluence at n_TOF has been characterized by means of five different measurements: ReactionShapeIntensity PTB 235 U(n,f)Yes Megas 235 U(n,f) & 10 B(n, ) Yes~ SiMon 6 Li(n,t)Yes (E n 30 keV) Setup Problems in reading the transformers Problems in alignment of detectors Beam Profile Protons: uMegas 1 Medipix 610 16 p Horizontal plane: Very good agreement with the expectations Vertical plane: Agreement assuming a tilted second collimator by -2mm Neutron fluence Protons: PTB 110 18 p 20-25% lower than the expectations collimator misalignment/tilt Resolution function + Energy-Time relation Protons: 410 17 p (+exploiting the statistics from Fe/Ni proposal) No significant change with the past Analysis still on progress Summary 2009: ongoing Sample scattered neutron background in TAC Cross-check 2 nd collimator alignment experimentally 2010: planned Borated water circuit operating in two modes 0% 10 B-content or fully saturated ~1% 10 B Measure: Neutron fluence Resolution Reduction effect of in-beam -rays On-going / future measurements