AIR MANAGEMENT & CONTROL PRODUCTS forNUCLEAR POWER PLANTS &
INDUSTRIAL PLANTS
DAMPERGRILLE
DIFFUSERLOUVER
SILENCERHUMIDIFIER
FO
RT
HE
BE
TT
ER
EN
VI
RO
NM
EN
TS
WI
TH
SA
FE
TY
AP
PL
IC
AT
IO
N
ISO 9001
Head office & Factory#563-1 Sipjeong-Dong, Bupyung-Gu, Incheon, Korea
Tel : +82-32-580-7300(rep.) Fax : +82-32-580-7399
Website : www.skps.kr
E-mail : [email protected] [email protected]
SAMKWANGPOWER SYSTEM CORP
We, ever since the modest beginning in 1988,have been a pioneer and leader in recognizingthe needs for air management products andair control devices that not only direct air butalso help control the indoor environment.
We have engaged in the various kinds ofconstruction project such as Industrial Factories,Houses, Laboratories, Electric & Electronic Facilities,Chemistry & Petrochemistry Plants, Subway/AirportTerminals, Nuclear Power Plants, etc. with rightmachinery & equipment capabilities, superiormanpower, and remarkable technical capability todesign, manufacture and erect of the wide ranges ofair control & ventilation products with best quality.
The modern world is changing rapidly andclients’ demands are varying faster than ever,so the wider variety of comprehensiveservices are required. In order tosuccessfully meet those requirements, ineverything we do, our management focus isan providing clients with the very best qualityproducts.
1
INTRODUCTION
Surely we have fabricated those bestcomplete lines of air distributing productsresulting from the workmanship of skilledpeople woven into the modern equipment &machinery and thanks to our best qualityproducts we have enjoyed a high reputationfrom clients.
Furthermore we are very eager to expand ouractivity & participation to abroad as offeringour advanced technology to overseascooperated partners, and to diversify ourproducts to sell in different markets. Basedon this conception of further branching out ourperformance we have taken part keenly inseveral overseas projects in Japan, China,Russia, Libya, Singapore, U.S.A., Malaysia,Indonesia, etc.
Parallel to our positive contribution, rooted in“The Sincerity Spirit and The Creativity ofWorkmanship” as the motto, we shall surelycontinue to dedicate ourselves to building
DESCRIPTION1) Using for Safety Related Zone/Non-
Safety Related Zone in Nuclear Power Plants or Other Industrial Plants.
2) Safety Related Equipment is capable of operating during and after accidentdue to Seismic Forces and otherloadings.
3) Basically the design, fabrication andperformance for Safety Related Equipment are based on the Seismic
&Environmental Requirements ofIEEE 323, 344 and 382.
4) The other requirements, which are not mentioned in IEEE or other criteria,can be fulfilled.
DESIGN & QUALIFICATION1) Meet the requirements ofpapa.5.9.3.2.
(Construction Class B) of ASME N509and Section DA-4000 of ASME AG-1.
2) Welding Requirements shall be in accordance with para. 7.3. of ASME N509 and ANSI/AWSD1.1. &3as applicable.
QUALITY ASSURANCEMeet the requirements of 10 CFR 50 App. B of ASME NQA-1 & USNRC.
GENERAL MATERIAL1) Conform to the requirements of
article DA-3000 of ASME AG-1 and Section 5.6.4. of ASME N509 or other equivalents.
2
Safety Related &
Non-SafetyRelated
Equipment
CODE No. SUBJECT
Test Method for Damper500AMCA
Reference Criteria
ANSI/AW
ASHRA
ASME
ASME
ASME
ASME
ASME
-
AG-1
B&PV
N509
NQA-1 & 2
B31.1
D1.1
Standard for Humidifiers
Leakage Rated Dampers for use inSmoke Control System
Standard for Fire Dampers
Material Standard (all applicable
Material Standard (all applicable
Standard for Qualifying Class 1EEquipment forNuclear Power Generating
IEEE Standards for Qualification of Actuatorfor Power Operated Valve Assemblies withSafety-Related Functions of Nuclear Power
Recommended Practicers for SeismicQualifi- cation for Class 1E Equipmentfor Nuclear Power Generating Stations
Structure Welding Code- Sheet
Welding and Brazing
Code on Nuclear Air and GasTreatment
Handbook-Fundamentals-DuctLiner Materials
Structure Welding Code-Steel
Quality Assurance ProgramRequirements for Nuclear
Power Piping
Nuclear Power Plant Air CleaningUnits and Components
Manual of Steel Construction AllowableStress Design
Environmental Qualification of ElectricEquip. Important to Safety for Nuclear
Quality Assurance Criteria for NuclearPower Plants and Fuel Reprocessing
Fire, Smoke and Radiational DamperInstallation Guide for HVAC System
-
10 CFR50. 49
10 CFR50 Appendix
998
555S
555
-
-
323
382
344
D1.3
-
USNRC
USNRC
ULUL
ULASTM
KS
IEEE
ANSI/IEE
ANSI/IEE
ANSI/AW
AISC
SMACN
Test Code for Grilles, Registers1062:GRD-84ADC
Method of Testing and PrefabricatedSilen-cers for Acoustic & Air Flow
E477ASTM
CUSTOMER PROJECT EQUIPMENTS a f e t y / N o n - S a f e t yRelated Dampers,GRD,Louvers, Silencers &
YGN 5 & 6(Korea)KEPCO
Main Supply Record (Nuclear
ELLIS &
DONG-AH
HANJUNG
DAEWOO
HYUNDAI
Korea Electric Power Corp.
Qinshan1&2
UCN 3 & 4(Korea)
UCN 3 & 4(Korea)
WOL 3 & 4(Korea)
WOL 2(Korea)
UCN 5 & 6(Korea)
S a f e t y / N o n - S a f e t yRelated Dampers,GRD,Louvers, Silencers &
YGN 5 & 6(Korea)
Non-Safety RelatedDampers & GRD
Engineering &Construction Corp.
Korea HeavyIndustries &
ConstructionIndustrial Co.,Ltd.
Non-Safety RelatedDampers & GRD
Non-Safety RelatedDampers & GRD
Non-Safety RelatedDampers & GRD
Non-Safety RelatedDampers & GRD
Non-Safety RelatedDampers & GRD
DESCRIPTIONThis damper is usually operated by handor pressure. This damper has twodifferent types as follows;
- Modulation Type- Isolation Type
Modulation Damper is used for airvolume (air flow) controlling function. Toreach the required air volume, thehandle(quadrant) should be positioned adesired point and hold by self- lockdevice.
This Modulation Damper is classified byBlade Type as follows;1) Opposed Blade Type Damper2) Butterfly Blade Type Damper
Isolation Damper is used for two positionsuch as Full Open and Full CloseFunction. (On-Off Function)When Damper being closed, normally acertain air leakage class should berequired based on ASME AG-1,depending on job-site or customerrequirements.
This Isolation Damper is classified byBlade Type as follows;1) Butterfly Blade Type Damper2) Check Damper3) Back Draft Damper
4
FRAME & SEAT LEAKAGE1) Fulfill the article DA-4140 of ASME
AG-12) Zero Leakage (Air Tight) Damper
available
CLASSIFICATION1) Manual Damper
- Modulation TypeOpposed Blade Type DamperButterfly Blade Type Damper
- Isolation TypeButterfly Type Damper Check DamperBack Draft Damper
2) Control Damper- Actuator Type
Pneumatic Control Damper(PSR)Hydraulic Control Damper(ESR)Electric Motor Control Damper(EM)
- Modulation TypeOpposed Blade Type DamperButterfly Blade Type Damper
- Isolation TypeParallel Blade Type DamperButterfly Type Damper Check DamperDual Disk Butterfly Damper
3) RCFC Check Damper
4) Fire Damper/Smoke Damper
5) Grille/Register/Diffuser (GRD)
6) Louver
7) Silencer
8) Humidifier
3
Safety Related &
Non-SafetyRelated
EquipmentMANUALDAMPER
DESCRIPTIONGenerally Leakage Class ¥† or ¥‡ isrequired for this damper in accordance withASME AG-1. Designed to meetConstruction Criteria of IEEE standards.This damper is Rectangular or Round.
FRAME/FLANGEGalvanized Steel, Carbon Steel andStainless Steel available in accordance withASTM or KS designation.
Integral Formed Channel Type Flange forRectangular Damper, and Welded Flangefor Round Damper.
BLADEGalvanized Steel, Carbon Steel andStainless Steel available in accordance withASTM or KS designation.
BLADE/SHAFT SEALNormally use E.P.D.M. or Neoprene.
SHAFT/LINKAGESteel or Stainless Steel in accordance withASTM or KS designation. Shaft Diameterand Linkage Size are various depending onDamper Size.
BEARINGPillow Block Flange Mounted & OilImpregnated Permanent Type.
6
DESCRIPTIONGenerally Leakage Class ¥† or ¥‡ isrequired for this damper in accordance withASME AG-1. Designed to meetConstruction Criteria of IEEE standard.This damper is rectangular.
FRAME/FLANGEGalvanized Steel, Carbon Steel andStainless Steel available in accordance withASTM or KS designation. Flange isIntegral Formed Channel type.
BLADEGalvanized Steel, Carbon Steel andStainless Steel available in accordance withASTM or KS designation.
BLADE SEALNormally use E.P.D.M. or Neoprene.
SHAFT/LINKAGESteel or Stainless Steel in accordance withASTM or KS designation. Shaft Diameterand Linkage Size are various depending onDamper Size.
BEARINGPillow Block Flange Mounted & OilImpregnated Permanent Type.
5
OPPOSED BLADEDAMPER
(MD-OB series)
BUTTERFLYBLADE
DAMPER(MD-BY/RBY series)
MANUAL DAMPER MANUAL DAMPER
MD-RBY(ROUND)
MD-BY(Rectangular)
DESCRIPTIONThis damper is normally installed in wall orin the terminal parts of duct-line. Thefunction is almost same as Check Damper.Generally Leakage Class¥–or ¥† is requiredfor this damper in accordance with ASMEAG-1. Designed to meet ConstructionCriteria of IEEE standards. CounterBalance applied. This damper isRectangular.
FRAME/FLANGEGalvanized Steel, Carbon Steel andStainless Steel available in accordance withASTM or KS designation. Flange is IntegralFormed Channel Type.
BLADEGalvanized Steel, Carbon Steel andStainless Steel available in accordance withASTM or KS designation.
BLADE/SHAFT SEALNormally use E.P.D.M. or Neoprene.
SHAFT/LINKAGESteel or Stainless Steel in accordance withASTM or KS designation. Shaft Diameterand Linkage Size are various depending onDamper Size.
BEARINGRolling Element Flange Mounted Type.
8
DESCRIPTIONThis damper is used for preventing a BackAir Flow in duct-line. The blade connectedto hinge post is closed by Back Pressure orBack Air Flow and opened under normalstatic pressure. This damper can beinstalled vertically or horizontally in duct-line. Generally Leakage Class¥–isrequired in accordance with ASME AG-1.
Designed to meet Construction Criteria ofIEEE standards. This damper isRectangular or Round.
FRAME/FLANGEGalvanized Steel, Carbon Steel andStainless Steel available in accordance withASTM or KS designation. Integral FormedChannel Type Flange for RectangularDamper, and Welded Flange for RoundDamper.
BLADEGalvanized Steel, Carbon Steel andStainless Steel available in accordance withASTM or KS designation.
BLADE SEALNormally use E.P.D.M. or Neoprene.
HINGE POSTGalvanized Steel in accordance with ASTMor KS designation.
7
BACK DRAFT
DAMPER(MD-BD series)
MANUAL DAMPER
CHECK DAMPER
(MD-CK/RCK series)
MANUAL DAMPER
MD-RCK(ROUND)
MD-CK(Rectangular)
DESCRIPTIONGenerally Leakage Class ¥†or ¥‡is requiredfor this damper in accordance with ASMEAG-1. Designed to meet ConstructionCriteria of IEEE standards. This damper isrectangular.
FRAME/FLANGEGalvanized Steel, Carbon Steel andStainless Steel available in accordance withASTM or KS designation. Flange is IntegralFormed Channel type.
BLADEGalvanized Steel, Carbon Steel andStainless Steel available in accordance withASTM or KS designation.
BLADE SEALNormally use E.P.D.M. or Neoprene.
SHAFT/LINKAGESteel or Stainless Steel in accordance withASTM or KS designation. Shaft Diameterand Linkage Size are various depending onDamper Size.
BEARINGPillow Block Flange Mounted & OilImpregnated Permanent Type.
ACTUATORPSR(Spring Return Type), ESR(SpringReturn Type) or EM(Electric Motor)
OPTIONSolenoid Valve (3-way type)Limit Switch (DP DT type)Positioner & Inverter
10
DESCRIPTIONThis damper is usually operated byPneumatic Actuator(PSR) or Electro-Hydraulic Actuator(ESR). This dampercan be equipped with other device suchas Solenoid Valve, Limit Switch,Positioner, etc. to control a damperblade precisely. This damper has twodifferent types as follows;
Modulation Type / Isolation type
Modulation Damper is used for airvolume (air flow) controlling function. Toreach the required air volume, 75~105psig of inlet pressure should beadjusted to 3~15psig of operatingpressure by 4~20mA of electric signal.(PSR Actuator Type). Electric HydraulicForce causes to modulate BalanceBeam with 4-20mA signal, and thisinduces to adjust the angle of the blades.(ESR Actuator Type) This operatingpressure can control the angle of eachblade.
This Modulation Damper is classified byBlade Type as follows;
1) Opposed Blade Type Damper2) Butterfly Blade Type Damper
Isolation Damper is used for two positionsuch as Open and Close Function. (On-Off Function) When Damper beingclosed, normally a certain air leakageclass should be required based onASME AG-1, depending on job-site orcustomer request.
This Isolation Damper is classified byBlade Type as follows;
1) Butterfly Blade Type Damper
9
CONTROLDAMPER
OPPOSED BLADEDAMPER
(ESR/PSR/EM-OBseries)
CONTROL DAMPER
PSR-OB series(Rectangular)
ESR-OB series(Rectangular)
DESCRIPTIONGenerally Leakage Class ¥–is requiredfor this damper in accordance withASME AG-1. Designed to meetConstruction Criteria, IEEE standards.This damper is rectangular. The bladeis operated in parallel as two position;Full Open and Full Close.
FRAME/FLANGEGalvanized Steel, Carbon Steel andStainless Steel available in accordancewith ASTM or KS designation. Flangeis Integral Formed Channel type.
BLADEGalvanized Steel, Carbon Steel andStainless Steel available in accordancewith ASTM or KS designation.
BLADE SEALNormally use E.P.D.M. or Neoprene.
SHAFT/LINKAGESteel or Stainless Steel in accordancewith ASTM or KS designation. ShaftDiameter and Linkage Size are variousdepending on Damper Size.
BEARINGPillow Block Flange Mounted & OilImpregnated Permanent Type.
ACTUATORPSR(Spring Return Type), ESR(SpringReturn Type) or EM(Electric Motor)
OPTIONSolenoid Valve (3-way type)Limit Switch (DP DT type)
12
DESCRIPTIONGenerally Leakage Class¥–, ¥†or ¥‡ isrequired for this damper in accordancewith ASME AG-1. Designed to meetConstruction Criteria, IEEE standards.This damper is Rectangular or Round.
FRAME/FLANGEGalvanized Steel, Carbon Steel andStainless Steel available in accordancewith ASTM or KS designation. IntegralFormed Channel Type Flange forRectangular Damper, and WeldedFlange for Round Damper.
BLADEGalvanized Steel, Carbon Steel andStainless Steel available in accordancewith ASTM or KS designation.
BLADE/SHAFT SEALNormally use E.P.D.M. or Neoprene.
SHAFT/LINKAGESteel or Stainless Steel in accordancewith ASTM or KS designation. ShaftDiameter and Linkage Size are variousdepending on Damper Size.
BEARINGPillow Block Flange Mounted & OilImpregnated Permanent Type.
ACTUATORPSR(Spring Return Type), ESR(SpringReturn Type) or EM(Electric Motor)
OPTIONSolenoid Valve (3-way type)Limit Switch (DP DT type)Positioner & Inverter
11
BUTTERFLYBLADE
DAMPER(ESR/PSR/EM-
BY/RBY series)
PARALLELBLADE
DAMPER(ESR/PSR/EM-PB
series)
CONTROL DAMPER CONTROL DAMPER
ESR-BY series(Rectangular)
PSR-RBYseries
ESR-PB series(Rectangular)
PSR-PB series(Rectangular)
DESCRIPTIONFIRE DAMPER is operated by heat when firebreaking. The fusible link should be meltdown by heat, and then the blade is shutdown as a curtain due to the force ofStainless Steel Closure Flat Spring as well asself-weight. So it is called as Curtain TypeFire Damper. Normally Class A 3-hour rated(UL Listed) is widely adopted. SMOKE DAMPER is damper is usuallyoperated by smoke detector as well as heatwhen fire breaking. When fire breaking, thefusible link is utilized automatically by signalfrom ionization detector. Leakage Class¥�should meet in accordance with UL555S.This damper has a handle for reset. Fire Damper is constructed by UL 555 andSmoke Damper, constructed by UL555S asdetermined ANSI/NEPA 90A andANSI/NEPA 803. This damper has a handlefor reset.
FRAME & BLADEGalvanized Steel, and Stainless Steelavailable in accordance with ASTM or KSdesignation.
FUSIBLE LINKUL Listed 165oF Fusible Link(FL) for FD-ELseries.Electric Thermal Fusible Link(ETL) for FD-ELand SD-EL series.
SPRINGStainless Steel Spring
SLEEVEBy others
14
DESCRIPTIONGenerally Leakage Class 0 or ¥�as AirTight Damper is required in accordancewith ASME AG-1. Designed to meetConstruction Criteria of IEEE standards.This damper is rectangular or round.Operating as Full Open and Full Close.
FRAME/FLANGEGalvanized Steel, Carbon Steel andStainless Steel available in accordancewith ASTM or KS designation. IntegralFormed Channel Type Flange forRectangular Damper, and WeldedFlange for Round Damper.
BLADEGalvanized Steel, Carbon Steel andStainless Steel available in accordancewith ASTM or KS designation.
BLADE SEALNormally use E.P.D.M. or Neoprene.
GEARED SHAFTStainless Steel in accordance withASTM or KS designation. ShaftDiameter is various depending onDamper Size. Linkage is option.
BEARINGPillow Block Flange Mounted & OilImpregnated Permanent Type.
ACTUATORPSR(Spring Return Type), ESR(SpringReturn Type) or EM(Electric Motor)
OPTIONSolenoid Valve (3-way type)Limit Switch (DP DT type)
13
DUAL DISKBUTTERFLY
DAMPER(ESR/PSR/EM-
DD/RDD series)
FIRE DAMPER(FD-FL/EL series)SMOKE DAMPER
(SD series)
CONTROL DAMPER
PSR-DD series(Rectangular)
ESR-RDD series(Round)
FD-FL series(Rectangular)
SD-EL series(Rectangular)
DESCRIPTIONDesigned to meet Construction Criteriaof IEEE, ADC1062 GRD-84 and ISO-5219, Air Distribution and Air DiffusionCriteria. Grille, Register and Diffuser(GRD) are for air distributing anddiffusion devices. Usually Grille andRegister are installed in the wall. SingleDeflection, Double Deflection or FixedLouver Blade for Grille/Register areavailable.
Grille with deflection blades can controlair flow vertically and/or horizontally.
Register is equipped with VolumeControl Damper (VCD) to control airvolume.
Diffuser is installed on ceiling. Diffuseris round or square shape. VolumeControl Damper to control air volume isavailable. Square Diffuser is 1 ~ 4Way.
FRAME/BLADEAluminum, Galvanized Steel, orStainless Steel body in accordance withASTM or KS designation.
GASKETUsually Neoprene
VCD-Opposed Blade DamperAluminum, Galvanized Steel, orStainless Steel in accordance withASTM or KS designation.
16
DESCRIPTIONDesigned to meet Construction Criteria ofIEEE standards. It has two types;Rectangular and Round. The blade ispositioned at Open Position under normalcondition with air flow. When hazard beinghappened, the blade should be closed withina certain time by Strong Spring equipped onthe back side of the blade and back flow.
FRAME/FLANGEPainted Carbon Steel body in accordancewith ASTM or KS designation. Flange forRectangular Damper is Integral FormedChannel Type, and Welded Flange forRound.
BLADEStainless Steel in accordance with ASTM orKS designation.
BLADE SEALNormally use E.P.D.M. or Neoprene
HINGE POSTPainted Carbon Steel or Stainless Steel inaccordance with ASTM or KS designation.Hinge Post size is various depending onDamper Size.
OPTIONLinkage - Galvanized, Carbon Steel orStainless Steel in accordance with ASTM orKS designation.Limit Switch for indicating
15
GRILLEREGISTERDIFFUSER(GRD series)
RCFC CHECK DAMPER
(RCFC series)
DIFFUSE
GRILLE
REGISTE
DESCRIPTIONDesigned to meet Construction Criteria of
IEEE & ASTM standards. Normally
Rectangular type is widely used for duct
installation. Mainly installed in the front of
Air Handling Units(AHU) or fan as well as
where sound attenuation is required.
Combusting rating for the Silencer acoustic
fill and sealant is in accordance with ASTM
E84 and NFPA 255, or the equivalent.
FRAMEGalvanized Steel body in accordance with
ASTM or KS designation.
SPLITThe front and back part of Split are
Galvanized Stainless Steel, and the side is
Perforated Galvanized Steel in accordance
with ASTM or KS designation.
INSULATIONGlass Cloth with Glass Wool or Glass
Fiber.
18
DESCRIPTIONDesigned to meet Construction & TestCriteria of AMCA standards. WaterPenetration Requirement forFixed/Operating Blade Type and LeakageClass for Operating Blade Type can befulfilled according to customer’s request.Louver is Classified by blade function asFixed Blade or Adjustable Blade as follows;1) Fixed Louver (A type)2) Operating Louver (B type)3) Operating Dual Combination
Louver (C type)4) Back Draft Dual Combination
Louver(Intake-D type/Exhaust-E type)
FRAME/BLADEGalvanized Steel, Stainless Steel andAluminum available in accordance withASTM or KS designation.
BLADE SEALNormally use Neoprene
BEARING for OPERATINGTYPEOilless Bearing for B ~ E Type
OPTIONActuatorSpecial Finish (Painting)
17
LOUVER(LV series)
SILENCER(SL series)
SPLIT
B/C type
E type D type
A type
3. CYCLE TIME TEST / 4. CYCLE REPETITION TEST
2. FLOW CHARACTERISTICS TEST
20
DESCRIPTIONDesigned to meet Construction Criteria ofIEEE, UL998 & 1013, and ASTMstandards. Humidifier consists ofEvaporating Chamber, Dispersion TubeSet, Electric Immersion Heater, Make-UpWater Valve, Control Box and HumidityControllers & Sensors.
The installation methods are;1) Floor Mounting 2) Trapeze Hanger Mounting3) Bracketed to Wall Mounting
Dispersion Tube is emitting dry steamwhich can be absorbed into running air floweasily.
EVAPORATING CHAMBERStainless Steel body in accordance withASTM or KS designation.
DISPERSION TUBE SETStainless Steel body in accordance withASTM or KS designation.
ELECTRIC IMMERSIONHEATERSheathe Material - Incoloy
MAKE UP WATER VALVEStainless Steel body in accordance withASTM or KS designation.
CONTROLLER/SENSORUL Listed/Recognized or equivalents
19
ELECTRICSTEAM
HUMIDIFIER(HF series)
PERFORMANCETEST
To measure the pressure loss onDamper Blade and Seat Bar. Ithas two different test; Duct TypeTest and Chamber Type Test.
This test is for Modulation TypeDampers only. After selectingfive different air f low values,measuring a pressure drop undereach air f low at different
¡�CYCLE REPETITIONTEST
This test is for Control
To measure whether there is anydifference between the requiredair pressure and the air pressureinduced into Actuator.
To measure air leak on frame andSeat. There are two leakagetests;
1)Frame Leak Test
¡�CYCLE TIME TESTTo measure the closing time of blade activated byActuator. This test is for
Isolation Damper
1. PRESSURE DROP TEST
Leakage to be measured causedby Friction and loosing ofcomponents during the repeatedoperating of damper blade.21,000 times repetition with Full
5. PNEUMATIC TEST
6. LEAKAGE TEST
4.5Kw
80Kw
Dispersion Tube Set
Control Panels
2221
TEST &
QUALIFICATION
TEST &
QUALIFICATION
FIRE DAMPER TEST at UL
Positioning FIRE DAMPER intothe furnace for Closing Test byUL engineer. (Horizontal Type)
Mounted FIRE DAMPER on thewall for Closing Test (VerticalType)
Performing Water Pressure Teston closed FIRE DAMPER Bladeto verify not to open by anypressure after finishing ClosingTest of FIRE DAMPER according
Checking and Inspecting theTest Result by UL engineer aftercompleting the whole test.
ELECTRIC STEAM HUMIDIFIER TEST at UL
PositioningHUMIDIFIER
(80Kw) forPerformance
Test for 30days.
Monitoring by ThermalRecorder during the
Testing
HUMIDIFIER(4.5Kw)Sample for UL Test inaccordance with UL
998.
SEISMIC & ENVIRONMENTAL TEST at WYLE LAB, Huntsville,
Vibration Test for Manual &Control Damper according to
Monitoring and Recording thewhole data during Seismic Test
Vibration Test for Fire Damper(Multi-Section) according to IEEE
QUALIFICATION REPORT from WYLE LAB.
Our Engineers with WYLEengineers at WYLE, USA