o2 presentation.ppt [read-only] - pml process · thermocouple leads electrode lead genesis. genesis...
TRANSCRIPT
Genesis O2
LAND LAND LAND LAND instruments
How to measure Oxygen
• In situ Vs Extractive
• Extractive ◊ Paramagnetic
◊ Zirconia Extraction
• In Situ◊ Zirconia
Genesis O2
LAND LAND LAND LAND instruments
In Situ Zirconia Measurement
• Principle of Operation Flue Gases
Zirconia
HeaterHeater
O formed
O dischargedto O
Air
2-
2-
Thermocouple
Porous PlatinumElectrodes
2
Genesis O2
LAND LAND LAND LAND instruments
In Situ Zirconia Measurement
• Principle of Operation Sensor Output across Electrodes is given by:
E = RT In P1 + C4F P2
where:R - Gas ConstantP1 - Air Oxygen LevelP2 - Flue Gas Oxygen LevelF - Faraday’s ConstantT - Absolute TemperatureC - Cell Constant
Genesis O2
LAND LAND LAND LAND instruments
In Situ Zirconia Measurement
• Principle of Operation
220
200
180
160
140
120
100
80
60
40
20
0
0.1 0.2 0.5 1.0 2.0 5.0 10 2025
mV
%O2
1400°C
600°C 20.9%
Genesis O2
LAND LAND LAND LAND instruments
In Situ Zirconia Measurements
• Advantages over sampling systems◊ Fast response
◊ Stable
◊ High output at low % 02
◊ Low interference
◊ In situ calibration (manual or automatic)
◊ Robust
◊ Easy to Install and Maintain
◊ Can be used for general purpose high temperature and hazardous area applications
Genesis O2
LAND LAND LAND LAND instruments
In Situ Zirconia Measurements
• Disadvantages against sampling System◊ Makes reading on wet basis
◊ Occasional chemical inference of sensor
Genesis O2
LAND LAND LAND LAND instruments
Genesis O2
LAND LAND LAND LAND instruments
• Product Range◊ Stand alone system
◊ Remote control system
◊ Universal control unit
◊ High temperature system
◊ Hazardous area system
genesis
Genesis O2
LAND LAND LAND LAND instruments
• Model g1200 & g1210 Probe
Flame Arrester
Optional
StandardPorous Ceramic
FilterZirconia Cell
Heater
Inner
Electrode
Outer
Electrode
Electrode
Contact
Thermocouple
Reference Air
Thermocouple
Leads
Electrode
Lead
genesis
Genesis O2
LAND LAND LAND LAND instruments
• Probe Features
◊ Insertion Lengths 0.4M, 1.0M, 1.5M, 2.0M
◊ Fixing Flange JIS or 2” ANSI
◊ Probe material stainless steel
◊ Flue gas temp range 0-600°C
◊ Flue gas pressure or 50cm WG
g enesis
Genesis O2
LAND LAND LAND LAND instruments
• Stand alone g1200
• Control unit part of probe
genesis
Genesis O2
LAND LAND LAND LAND instruments
• g 1200 Stand Alone Oxygen System Features:◊ Display on probe
◊ Diagnostics on probe
◊ User interface on probe
◊ System confirmation on probe
◊ System fault indication on probe
◊ Analogue output (optional track or hold)
◊ Customer configured alarms
◊ Serial communication (RS 485 Modbus Protocol)
◊ Manual or Auto calibration trigger
◊ IP65 enclosed
◊ Universal Power input
genesis
Genesis O2
LAND LAND LAND LAND instruments
• Remote / Universal Control Unit g1220 ◊ Can be used with Genesis g 1210 probe
◊ Compatible with probes of other manufacturers
◊ All setting as stand alone unit
◊ Used with high temperature Genesis g 1230 probe
◊ Supplied with wall mounting flange
genesis
Genesis O2
LAND LAND LAND LAND instruments
• High Temperature Probe g 1230◊ Works with remote control g 1220
◊ Gas Temperature range 600 - 1400°C
◊ Probe lengths 556 or 953mm
◊ Various sheath materials depending on Temperature• Incoloy up to 1000°C
• Alumnus Porcelain up to 1250°C
• Recrystalised Alumina up to 1400°C
genesis
Genesis O2
LAND LAND LAND LAND instruments
• Automatic Calibration Flow/Control Unit g 1270◊ For auto calibration of stand alone and remote systems
◊ Use where regular calibration required
◊ Often required for compliance monitoring
g enesis