Page 1: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

Occupancy Classifications and Loads

Page 2: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

You must always determine the occupancy classification and the occupancy load to establish the parameters that are to be used for your project.

Page 3: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

An occupancy classification is assigned to the building or space. It is a broad classification. (educational)

Building type is more specific. It is a specific class or category within an occupancy. (high school)

Page 4: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

The number of people or occupants for which the code will require you to provide means of egress or exiting in your design.

The occupant load sets the minimum level of exiting that must be provided Number of exits Widths of corridors Distance to nearest exit

Page 5: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

The maximum number that can occupy the space.

Page 6: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

Must be assigned to the building or to a space within the building

One of the most important steps in the code process

Should be the first thing you determine when designing an interior

Page 7: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

Will affect code requirement pertaining to: Occupant load Means of egress Egress capacities Finish selection Number of plumbing fixtures As well as other areas (shown in fig. 2.1,

page 44)

Page 8: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

New buildings are usually determined.Buildings with different types of tenants

require that occupancy classifications be determined for each tenant.

Careful attention to renovation work (ie: a warehouse converting to apartments)

Have a code official approve your decision if you are unsure

Page 9: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

The ten most common occupancies are: Assembly Business Educational Factory or Industrial Hazardous Institutional Mercantile Residential Storage Utility and Misc.

Page 10: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

You will need to know three things before you can accurately determine the occupancy classification The type of activity occurring The expected number of occupants and If any unusual hazards are present

These factors can affect the classification of a building type. (ie: if a particular building is planned to serve a large number of people, it may be classified as an Assembly)

Page 11: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

Unusual hazards can either change an occupancy to a stricter classification or simply require all or part of a building to be classified as a Hazardous occupancy…subject to tougher codes. (page 47) Large groups of people Night occupancies Mobility of occupants Familiarity of occupants Potential spread of fire

Page 12: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

Refer to pages 56-72

Page 13: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

Incidental Use (page 75) (hazardous areas that are relatively small, storage, furnace rooms, boiler rooms, etc.) Additional fire and smoke protection may be required.

Mixed Occupancies: more than one occupant type under one roof. (Hotels with restaurants, ballrooms, exercise rooms will be both Assembly and Business)

Page 14: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

Whether an occupancy is new or existing becomes important when using the LSC.

An occupancy is considered new if it falls in the following categories: New construction Relocation into an existing building New addition to an existing building Occupancy is staying in existing space,

but changing size or use

Page 15: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

When two or more occupancies occur in the same building

Trend for the future Different codes will apply to each Requires fire-walls between spaces Treat as its own entity

Office building with a childcare center (Business/Educational)

Hospitals with cafeterias (Institutional/Assembly)

Malls with food courts (merchantile/assembly)

Page 16: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

Certain occupancy classifications are also affected by the ADA.

Federal building and 1 and 2 family dwelling are not regulated by the ADA. Restaurants and Cafeterias (Assembly) Libraries (business or educational) Mercantile and many businesses Medical (healthcare) Transient lodging (residential and

correctional/detention) Childcare

Page 17: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

An occupant load is the second thing you need to determine at the beginning of a project.

It sets the minimum number of occupants for which you must design the means of egress from a building or specific area.

Each code set a predetermined amount of space or sq. ft for each occupant. This figure is called the load factor.

Page 18: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

The load factor is used to help you determine the occupant load for a space or a building.

The load factor will help to determine the number of people that will be using the corridors, stairs and exits in the event of a fire

See table on page 89.

Page 19: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

This factor indicates the amount of space or area it is assumed each person present will require

Although the sq foot figures may seem high for one person, they allow for furniture and equipment and in some cases corridors, closets and other miscellaneous areas.

It is always represented in sq. feet; however, it can be a gross or a net figure.

Page 20: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

The gross area refers to the building as a whole and includes all misc. spaces within the exterior walls.

The net area refers to actual occupied spaces and does not include accessory spaces such as corridors, restrooms, utility closets etc.

When net figures are required, it is assumed that the occupants who are using an accessory area would have left the occupied space to do so. (ex: a student walking in a hallway would already have been counted as a student in the classroom)

Note: a Load factor has nothing to do with individual space allocation with planning a facility.

Page 21: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

Occupancy Load = Floor Area (sq. ft) / Occupant Factor

It can be used two ways Help determine the required area in sq.

feet for a new structure (you will need to know roughly how many people will use the building and the classification of the building.)

Determine the occupancy size allowed in a building of a set sq. footage. (existing buildings)

Page 22: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are
Page 23: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

Even if you know that your client will have fewer occupants, you must plan the space based on the determined load figures as required by the codes.

Page 24: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

You must figure each occupant load separately

Example: Multistory buildings may have mercantile, business on one floor. Figure each occupancy type for each floor and add them together

Page 25: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

Example wasTemple Baptist Church prior to construction of new sanctuary: Worship hall is also a basketball court Fellowship hall is also cafeteria

Figure the occupancy load based on the largest concentration of people.

Page 26: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

Common in Assembly occupancies The seats are considered fixed if they do

not easily move. Theaters Churches Stadiums, bleachers

Do not use standard formula Count actual seats For seats without arms, figure 18” for

each occupant 12’ pew is 144” divided by 18 = 8 people

Page 27: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

The occupant load that you determine in the beginning of a project will be used again later in your code research to determine the means of egress, such as The number of exits Width of exits Placement of exits

Page 28: Occupancy Classifications and Loads. You must always determine the occupancy classification and the occupancy load to establish the parameters that are

Every assembly room or Assembly occupancy usually requires the approved occupant load to be permanently posted near the main exit from the space.

A typical sign might read “Occupancy by more than 100 persons

is dangerous and unlawful.”