octave

6
A Tuned Measure

Upload: sharon-maxmark

Post on 17-Mar-2016

226 views

Category:

Documents


1 download

DESCRIPTION

ultrasonic bulk water meter

TRANSCRIPT

Page 1: Octave

AMR Ready

No Moving Parts

ARAD 3G built-in and Easy connection to any automated metering reading system.

No wear - Therefore low maintenance.

A T u n e d M e a s u r e

Oct

ave-

Feb.

09

ARAD is proud to introduce the OCTAVE, a new

revolutionary, precise and super reliable ultrasonic bulk water meter.

This new meter, having both superior hydraulic performance as well

as advanced alert, data and statistical features, will naturally lead the world of water

management.

LeakageThe leaks detection module maps the physical network structure into groups. Utilizing a smart algorithm, it is able to calculate even the slightest water loss within any specific group, or between main groups and sub-groups.

Theft The system is specially programmed to "know" how to identify water theft; either directly from the meter or from the line (between meters). It immediately alerts the utility customer by mail, fax or cellular phone.

Damage The system is also capable of identifing deliberate damage to the meters, and immediately alerts the utility customer by mail, fax or cellular phone.

BackFlowThe system recognizes if a meter is installed incorrectly, in the wrong direction, or has been deliberately altered by the end user. The meter sends an alert notification that consumption is flowing in the wrong direction.

ARAD Technologies net management service (ATUS2000.COM) supplies the utility with a range of effective tools to manage and control its water, gas & electricity network. The system includes detection modules such as:

ARAD AMR Solutions

Innovation through precision,

Arad Ltd. Association Dalia Ramot-Menashe, 19239 Dalia, ISRAELTel: (972)4-9897911 Fax: (972)4-9897965 Email: [email protected] w w w. a r a d . c o . i l

quality and performance

BackFlowThe system recognizes if a meter is installed incorrectly, in the wrong direction, or has been deliberately altered by the end user. The meter sends an alert notification that consumption is flowing in the wrong direction.

Page 2: Octave

AMR Ready

No Moving Parts

ARAD 3G built-in and Easy connection to any automated metering reading system.

No wear - Therefore low maintenance.

A T u n e d M e a s u r e

Oct

ave-

Feb.

09

ARAD is proud to introduce the OCTAVE, a new

revolutionary, precise and super reliable ultrasonic bulk water meter.

This new meter, having both superior hydraulic performance as well

as advanced alert, data and statistical features, will naturally lead the world of water

management.

LeakageThe leaks detection module maps the physical network structure into groups. Utilizing a smart algorithm, it is able to calculate even the slightest water loss within any specific group, or between main groups and sub-groups.

Theft The system is specially programmed to "know" how to identify water theft; either directly from the meter or from the line (between meters). It immediately alerts the utility customer by mail, fax or cellular phone.

Damage The system is also capable of identifing deliberate damage to the meters, and immediately alerts the utility customer by mail, fax or cellular phone.

BackFlowThe system recognizes if a meter is installed incorrectly, in the wrong direction, or has been deliberately altered by the end user. The meter sends an alert notification that consumption is flowing in the wrong direction.

ARAD Technologies net management service (ATUS2000.COM) supplies the utility with a range of effective tools to manage and control its water, gas & electricity network. The system includes detection modules such as:

ARAD AMR Solutions

Innovation through precision,

Arad Ltd. Association Dalia Ramot-Menashe, 19239 Dalia, ISRAELTel: (972)4-9897911 Fax: (972)4-9897965 Email: [email protected] w w w. a r a d . c o . i l

quality and performance

BackFlowThe system recognizes if a meter is installed incorrectly, in the wrong direction, or has been deliberately altered by the end user. The meter sends an alert notification that consumption is flowing in the wrong direction.

Page 3: Octave

Digital Display

Measuring Principle

Ultrasonic Transducers

Long Life Battery Powered

Electrical Output Resolution (Quantity/Pulse)

m3 GAL A.F. CuFt.

10 1000 0.1 10001 100 0.01 100

0.100 10 0.001 100.010 1 0.0001 10.001 0.1 0.00001 0.1

Dimensions

Model Octave

Nominal size(mm) 50 80 100

(inch) 2 3 4

L – Length (mm) 200 200 250

B – Width (mm) 165 200 200

H – Height (mm) 214 234 250

h – Height (mm) 70 90 106

Weight (kg) 12 15.5 19

Imagine two identical swimmers crossing a river on the same diagonal line, one with

the flow and the other against the flow. The swimmer moving with the flow needs much

less time to reach the opposite bank.

Ultrasonic waves behave exactly the same way. The sound wave that flows in the direction of the

stream moves faster than the one that flows against the stream.

The transit times TAB (Transit time of ultrasonic waves from sensor A to sensor B) and TBA

(from sensor B to A) are measured continuously. The time difference (TBA - TAB) is directly proportional to the mean flow velocity (Vm) of the liquid.

The flow rate is a result of the velocity multiplied by the cross section area of the flow tube size.

Performance Data ISO 4064-2005 Performance Requirements Octave Q4

Maximum flowrate (m3/h)

Q3Nominal Flowrate(m3/h)

Q2Transitional

Flowrate(L/h)

Q1Minimum Flowrate

(L/h)

R10Q3/Q1

Nominal Size

mm inch

50 2 50 40 125 80 50080 3 80 63 200 125 500100 4 125 100 320 200 500

Octave Q4 Maximum flowrate (m3/h)

Q3Nominal Flowrate(m3/h)

Q2Transitional

Flowrate(L/h)

Q1Minimum Flowrate

(L/h)

R10Q3/Q1

Nominal Size

mm inch

50 2 50 40 250 160 25080 3 80 63 400 250 250100 4 125 100 650 400 250

Accuracy Curve

±5% accuracy limit±2% accuracy limit

Delivery in % Qmax

+5+2-20

0

-5-10

E%

Q1 Q4Q2 Q3

Head Loss Curve

Octa

ve 2

Octa

ve 3

Oct

ave

4”

1251008050400.0

1.0

1.5

2.0

2.5H(m)

Q(m3/h)

Technical Specifications

Rugged Mechanical Design

Working Pressure

Liquid Temperature

Metrological Characteristics

Configuration

Power Source

Environmental Protection

Display Units

Output (optional)

16 bar

0.1-50°C

ISO 4064-1 Third Edition (2005)

Compact - The display is built in to the unit

2 D size Li-battery -10 years life time

IP 68, Ambient operation temp. -25°C ÷ +55°C

Multi line 9 digit LC display (Programmable - m3, USG, CuFt. Acre Feet, Flow rate and volume)

Programmable single/dual open collector pulse outputPowered loop 4-20 mA

Vacuum sealed IP68 construction for long life and high performance.

Water Measuring Technologies

Flow direction icon

Output Mode

3G/GSM- Active communication

Leak detector

Volume unitsm3

Flow rate unitsm3/h

Battery level icon

Alarm/Error icon

10 years life expectancy

Double beam ultrasonic sensors for high accuracy and reliable operation.

H

L B

h

Page 4: Octave

Digital Display

Measuring Principle

Ultrasonic Transducers

Long Life Battery Powered

Electrical Output Resolution (Quantity/Pulse)

m3 GAL A.F. CuFt.

10 1000 0.1 10001 100 0.01 100

0.100 10 0.001 100.010 1 0.0001 10.001 0.1 0.00001 0.1

Dimensions

Model Octave

Nominal size(mm) 50 80 100

(inch) 2 3 4

L – Length (mm) 200 200 250

B – Width (mm) 165 200 200

H – Height (mm) 214 234 250

h – Height (mm) 70 90 106

Weight (kg) 12 15.5 19

Imagine two identical swimmers crossing a river on the same diagonal line, one with

the flow and the other against the flow. The swimmer moving with the flow needs much

less time to reach the opposite bank.

Ultrasonic waves behave exactly the same way. The sound wave that flows in the direction of the

stream moves faster than the one that flows against the stream.

The transit times TAB (Transit time of ultrasonic waves from sensor A to sensor B) and TBA

(from sensor B to A) are measured continuously. The time difference (TBA - TAB) is directly proportional to the mean flow velocity (Vm) of the liquid.

The flow rate is a result of the velocity multiplied by the cross section area of the flow tube size.

Performance Data ISO 4064-2005 Performance Requirements Octave Q4

Maximum flowrate (m3/h)

Q3Nominal Flowrate(m3/h)

Q2Transitional

Flowrate(L/h)

Q1Minimum Flowrate

(L/h)

R10Q3/Q1

Nominal Size

mm inch

50 2 50 40 125 80 50080 3 80 63 200 125 500100 4 125 100 320 200 500

Octave Q4 Maximum flowrate (m3/h)

Q3Nominal Flowrate(m3/h)

Q2Transitional

Flowrate(L/h)

Q1Minimum Flowrate

(L/h)

R10Q3/Q1

Nominal Size

mm inch

50 2 50 40 250 160 25080 3 80 63 400 250 250100 4 125 100 650 400 250

Accuracy Curve

±5% accuracy limit±2% accuracy limit

Delivery in % Qmax

+5+2-20

0

-5-10

E%

Q1 Q4Q2 Q3

Head Loss Curve

Octa

ve 2

Octa

ve 3

Oct

ave

4”

1251008050400.0

1.0

1.5

2.0

2.5H(m)

Q(m3/h)

Technical Specifications

Rugged Mechanical Design

Working Pressure

Liquid Temperature

Metrological Characteristics

Configuration

Power Source

Environmental Protection

Display Units

Output (optional)

16 bar

0.1-50°C

ISO 4064-1 Third Edition (2005)

Compact - The display is built in to the unit

2 D size Li-battery -10 years life time

IP 68, Ambient operation temp. -25°C ÷ +55°C

Multi line 9 digit LC display (Programmable - m3, USG, CuFt. Acre Feet, Flow rate and volume)

Programmable single/dual open collector pulse outputPowered loop 4-20 mA

Vacuum sealed IP68 construction for long life and high performance.

Water Measuring Technologies

Flow direction icon

Output Mode

3G/GSM- Active communication

Leak detector

Volume unitsm3

Flow rate unitsm3/h

Battery level icon

Alarm/Error icon

10 years life expectancy

Double beam ultrasonic sensors for high accuracy and reliable operation.

H

L B

h

Page 5: Octave

Digital Display

Measuring Principle

Ultrasonic Transducers

Long Life Battery Powered

Electrical Output Resolution (Quantity/Pulse)

m3 GAL A.F. CuFt.

10 1000 0.1 10001 100 0.01 100

0.100 10 0.001 100.010 1 0.0001 10.001 0.1 0.00001 0.1

Dimensions

Model Octave

Nominal size(mm) 50 80 100

(inch) 2 3 4

L – Length (mm) 200 200 250

B – Width (mm) 165 200 200

H – Height (mm) 214 234 250

h – Height (mm) 70 90 106

Weight (kg) 12 15.5 19

Imagine two identical swimmers crossing a river on the same diagonal line, one with

the flow and the other against the flow. The swimmer moving with the flow needs much

less time to reach the opposite bank.

Ultrasonic waves behave exactly the same way. The sound wave that flows in the direction of the

stream moves faster than the one that flows against the stream.

The transit times TAB (Transit time of ultrasonic waves from sensor A to sensor B) and TBA

(from sensor B to A) are measured continuously. The time difference (TBA - TAB) is directly proportional to the mean flow velocity (Vm) of the liquid.

The flow rate is a result of the velocity multiplied by the cross section area of the flow tube size.

Performance Data ISO 4064-2005 Performance Requirements Octave Q4

Maximum flowrate (m3/h)

Q3Nominal Flowrate(m3/h)

Q2Transitional

Flowrate(L/h)

Q1Minimum Flowrate

(L/h)

R10Q3/Q1

Nominal Size

mm inch

50 2 50 40 125 80 50080 3 80 63 200 125 500100 4 125 100 320 200 500

Octave Q4 Maximum flowrate (m3/h)

Q3Nominal Flowrate(m3/h)

Q2Transitional

Flowrate(L/h)

Q1Minimum Flowrate

(L/h)

R10Q3/Q1

Nominal Size

mm inch

50 2 50 40 250 160 25080 3 80 63 400 250 250100 4 125 100 650 400 250

Accuracy Curve

±5% accuracy limit±2% accuracy limit

Delivery in % Qmax

+5+2-20

0

-5-10

E%

Q1 Q4Q2 Q3

Head Loss Curve

Octa

ve 2

Octa

ve 3

Oct

ave

4”

1251008050400.0

1.0

1.5

2.0

2.5H(m)

Q(m3/h)

Technical Specifications

Rugged Mechanical Design

Working Pressure

Liquid Temperature

Metrological Characteristics

Configuration

Power Source

Environmental Protection

Display Units

Output (optional)

16 bar

0.1-50°C

ISO 4064-1 Third Edition (2005)

Compact - The display is built in to the unit

2 D size Li-battery -10 years life time

IP 68, Ambient operation temp. -25°C ÷ +55°C

Multi line 9 digit LC display (Programmable - m3, USG, CuFt. Acre Feet, Flow rate and volume)

Programmable single/dual open collector pulse outputPowered loop 4-20 mA

Vacuum sealed IP68 construction for long life and high performance.

Water Measuring Technologies

Flow direction icon

Output Mode

3G/GSM- Active communication

Leak detector

Volume unitsm3

Flow rate unitsm3/h

Battery level icon

Alarm/Error icon

10 years life expectancy

Double beam ultrasonic sensors for high accuracy and reliable operation.

H

L B

h

Page 6: Octave

AMR Ready

No Moving Parts

ARAD 3G built-in and Easy connection to any automated metering reading system.

No wear - Therefore low maintenance.

A T u n e d M e a s u r e

Oct

ave-

Feb.

09ARAD is proud to introduce

the OCTAVE, a new revolutionary, precise and super

reliable ultrasonic bulk water meter.This new meter, having both

superior hydraulic performance as well as advanced alert, data and statistical

features, will naturally lead the world of water management.

LeakageThe leaks detection module maps the physical network structure into groups. Utilizing a smart algorithm, it is able to calculate even the slightest water loss within any specific group, or between main groups and sub-groups.

Theft The system is specially programmed to "know" how to identify water theft; either directly from the meter or from the line (between meters). It immediately alerts the utility customer by mail, fax or cellular phone.

Damage The system is also capable of identifing deliberate damage to the meters, and immediately alerts the utility customer by mail, fax or cellular phone.

BackFlowThe system recognizes if a meter is installed incorrectly, in the wrong direction, or has been deliberately altered by the end user. The meter sends an alert notification that consumption is flowing in the wrong direction.

ARAD Technologies net management service (ATUS2000.COM) supplies the utility with a range of effective tools to manage and control its water, gas & electricity network. The system includes detection modules such as:

ARAD AMR Solutions

Innovation through precision,

Arad Ltd. Association Dalia Ramot-Menashe, 19239 Dalia, ISRAELTel: (972)4-9897911 Fax: (972)4-9897965 Email: [email protected] w w w. a r a d . c o . i l

quality and performance

BackFlowThe system recognizes if a meter is installed incorrectly, in the wrong direction, or has been deliberately altered by the end user. The meter sends an alert notification that consumption is flowing in the wrong direction.