Odour and Air Management StudiesKey Tool in Determining Effective Odour Control Solutions
Presented by:Wayne Wong, M.A.Sc, EIT
September 28, 2011
2Project Team
Yuko Suda, P.Eng. – Kerr Wood Leidal Associates Ltd.
Ted Steele, P.Eng. – Kerr Wood Leidal Associates Ltd.
Karl Mueller, P.Eng. – Kerr Wood Leidal Associates Ltd.
Chris Hunniford, PE – OCTC, a V&A Company
September 28, 2011
3Introduction to Sanitary Odours
Sewer odours can be found everywhere!• Gravity sewers• Air vents• Pump stations• Forcemains• Manholes• Wastewater treatment plants
Operational headache and nuisance
Costly problem for municipalities
September 28, 2011
4Source of Odours in Sanitary Systems
Odour Generation + Odour Release = Problem
Odour GenerationCombination of organic waste material and bacteria in the sewer
generates hydrogen sulfide (H2S) and volatile organic compounds (VOCs)
Especially problematic in collection systems with large detention times
Odour ReleaseLocal pressurization of the air space above sewage results in odourous
air being released from a contained space (sewer, manhole, tanks)
September 28, 2011
5Odour Generation
Occurs where there are large concentrations of organic waste materials and bacteria in the collection system
Odour generation is accelerated under the right environmental conditions
- Anaerobic conditions (typical in long forcemains or in collection systems with long hydraulic detention times)
Odour generation is generally difficult to avoid
September 28, 2011
6Odour Release
Odourous compounds generally exist within the collection system headspace.
These odourous compounds become a nuisance when there is pressurization and air movement which transport these odourous compounds from the headspace and released into the environment
There are a number of physical mechanisms that result in pressurization. The primary mechanism is air movement in the sewer due to the effects of friction drag
September 28, 2011
7Air Movement in Sewers
The primary force for air movement in gravity systems is the friction between the sewer headspace air and the moving wastewater below.
Resistance to air movement due to friction between air and pipe wall
An idealized velocity gradient can be developed based on these simple boundary conditions
September 28, 2011
8Air Movement in Sewers
Friction factor between water and air varies depending on factors such as turbulence and rough water surfaces (high friction factor)
Slower moving, quiescent water surfaces will generally result in a lower friction factor.
The flow rate of air that is conveyed is proportional to the air velocity in the headspace and the cross sectional area of the headspace
September 28, 2011
9Pressurization in Sewer Headspace
Occurs when there are abrupt changes in rate of air flow in the sewer
High flow rate of air from one section colliding with air in a downstream section that has a lower air flow rate
Change in air flow rates can be caused by changes in pipe slope and/or restrictions in the sewer headspace
When an area of pressurization coincides with a vent or manhole, sewer air will be expelled at that point
September 28, 2011
10Other Factors That Can Contribute to Odour Ventilation Problems
Change in atmospheric (barometric) pressure or ambient temperature (air density change) can cause air movement in/out of the collection system
Strong surface winds can draw air out of the collection system via eduction
Decrease in pipe diameter in downstream pipe sections
Opposing or perpendicular flows entering a junction can cause a
temporary backup of air
September 28, 2011
11Other Factors That Can Contribute to Odour Ventilation Problems
Ventilation effects are more pronounced in collection systems with fewer service connections, vents and manholes, where there are fewer relief points for expelling air
Ventilation effects can be most severe at inverted siphons, full-flowing or surcharged sewers and pump stations where airflow can be stopped completely, creating high pressures in the sewers
September 28, 2011
12Developing Solutions
Conventional solution has been to seal manholes or install carbon scrubbers
This results in increased air pressurization of the overall collection system and causes air to be expelled elsewhere.
This is a reactive approach which shifts the problem to another location rather than solving the problem
September 28, 2011
13Developing Solutions
Completing an odour and air management study to determine the most effective mitigation strategy is a more proactive approach
A comprehensive odour and air management study can be used to:
• Determine the root cause of odour emissions• Develop options to eliminate problems while minimizing
capital and operating costs.
September 28, 2011
14Odour and Air Management Study
An effective odour control and air management study includes:
• Monitoring program (H2S, VOCs, differential air pressure)
• Ventilation modeling (areas of pressurization, air flow rates, ventilation dynamics, release points)
• Hydraulic modeling (displacement effects)
Based on the above study, an evaluation can be conducted to develop the most effective strategy for mitigating odour
September 28, 2011
17Odour and Air Management Study
An evaluation can be conducted to develop the most effective strategy for mitigating odour emissions
Key Considerations:•Cost•Feasibility of implementation•Environmental impacts (hazardous chemicals, noise, etc.)•Overall treatment effectiveness
September 28, 2011
18Active Odour Control Facilities
An active odour control facility draws air from the sewer using a fan, treats it, and releases it to the atmosphere.
Types of treatment include biofilters, activated carbon adsorbers, and chemical scrubbers etc.
Drawing air in from the sewer with a blower and treating it creates an area of negative pressure (zone of influence) in the vicinity of the collection system within the sewer.
September 28, 2011
19Case Study – Highbury InterceptorMetro Vancouver
The Highbury Interceptor is owned and operated by Metro Vancouver.
Combined sewer (expected to be fully separated by 2050)
Total length = 6 km
Pipe diameter – 2,900 mm
Significant odour complaints and headspace pressurization issues
Noise issues during winter storms in which large volumes of air are expelled from vents
Manhole lids have been observed to be blown off
September 28, 2011
20Case Study – Highbury InterceptorMetro Vancouver
Monitoring of differential pressure, H2S, and VOCs were carried out during both wet and dry weather periods
Differential pressure indicated significant positive pressure occurs throughout the Highbury Interceptor
Ventilation modeling estimated the drag airflow at 10,000 cfm
Downstream end of the interceptor is a siphon, and no air can be conveyed beyond this point, creating an area of high pressurization
September 28, 2011
21Case Study – Highbury InterceptorMetro Vancouver
Hydraulic modeling indicated that sections of sewer becomes completely isolated from upstream, downstream, and tributary sewers during high flow (backwatering)
The ventilation model estimated that a typical storm could displace up to 7,000 cfm
Model indicated that as sewage level increase, a large amount of air can only be displaced at a few small vents (high pressure and high air discharge velocity)
September 28, 2011
22Case Study – Highbury InterceptorMetro Vancouver
KWL/OCTC project team proposed three active odour control facilities along the interceptor sewer
The main active odour control facility, with a design treatment capacity of 10,000 cfm, would have a zone of influence of approximately 4.6 km
September 28, 2011
23Conclusion
An odour control and air management study that includes monitoring, ventilation modeling, and hydraulic modeling is key to determining the root cause of odour complaints and can be used to develop a cost effective solution for controlling odour in a sanitary collection system.