oem & odm business are welcome! · communication protocol: ansi c12.18, ansi c12.19 electricity...

4
ANSI C12.20 class 0.5 % accuracy High accuracy 16-bits A-D Wide range of current measurement from 0.001Ib to 6.77Ib Two models of 5Amp and 30 Amp Full power parameter measures of Watt, Var, VA, pf... Multi-tariff with TOU (Time-of-Use rate) Four quadrant measurement Block and rolling demand measurement Record load profile Communication of RS-485, modem or power line carrier Energy pulse output Low cost Wide range of power input 96~528V Wide range of operating temperature -40~80˚C LCD displays around 400 items IEC60687, ANSI C12.18, C12.19 & C12.20 FEATURES OEM & ODM business are welcome! BRAINCHILD

Upload: others

Post on 26-Mar-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OEM & ODM business are welcome! · Communication protocol: ANSI C12.18, ANSI C12.19 Electricity and Environmental tests: IEC 60687 or ANSI C12.20 The memory to record the loading:

• ANSI C12.20 class 0.5 % accuracy

• High accuracy 16-bits A-D

• Wide range of current measurement from 0.001Ib to 6.77Ib

• Two models of 5Amp and 30 Amp

• Full power parameter measures of Watt, Var, VA, pf...

• Multi-tariff with TOU (Time-of-Use rate)

• Four quadrant measurement

• Block and rolling demand measurement

• Record load profile

• Communication of RS-485, modem or power line carrier

• Energy pulse output

• Low cost

• Wide range of power input 96~528V

• Wide range of operating temperature -40~80˚C

• LCD displays around 400 items

• IEC60687, ANSI C12.18, C12.19 & C12.20

FEATURES

OEM & ODM business are welcome!

BRAINCHILD

Page 2: OEM & ODM business are welcome! · Communication protocol: ANSI C12.18, ANSI C12.19 Electricity and Environmental tests: IEC 60687 or ANSI C12.20 The memory to record the loading:

1. “ Norm ” – in normal operation mode

2. “ Test ” – in test operation mode

3. “ Alt ” – in alternative mode to display messages

4. “ Cali ” – in calibration mode

5. “ Comx ” – in communication mode

6. It displays code of Watt, Volt, Amp, Var, VA, pf, etc. If it is illuminated as “ CA ” or “ AL ”, then caution or alarm status occurs.

7. It displays the value of Watt, Volt, Amp, RMS, Var, VA, pf, etc. Once “ CA ” or “ AL ” is illuminated, the following code is illuminated on these bigger 7 segments too.

Caution codes:

0001: not programmed yet

0002: potential low voltage

0003: received KWH

0004: leading KVARH

0005: overload the demand

Alarm codes:

0001: voltage imbalance

0002: inactive current

0003: under the normal voltage

0004: over the normal voltage

8. “ A ” illuminated means A phase voltage input.

9. “ B ” illuminated means B phase voltage input.

10. “ C ” illuminated means C phase voltage input.

11. “ Cum ” illuminated means it displays cumulative demand value.

12. Both “ Cont ” and “ Cum ” illuminated means it continuously displays cumulative demand value.

13. “ Prev ” illuminated means it displays previous data.

14. “ Max ” illuminated means it displays the maximum demand value.

15. The unit of present displaying value

16. “ El ” illuminated means end of interval time to stop counting the demand value.

17. “→” illuminated means the meter delivers the energy to the loading part.

18. “←” illuminated means the meter received the energy from the loading part.

19. “ Leading ” illuminated means Varh is leading ahead.

20. “ Lagging ” illuminated means Varh is lagging behind.

21. 10 bars is to divide the Kt Watthours by 10 divisions between two pulses.

22 ~ 25. A, B, C, D mean different period time of use applied for different rates. Only one is illuminated at a time.

LCD Function Description

Page 3: OEM & ODM business are welcome! · Communication protocol: ANSI C12.18, ANSI C12.19 Electricity and Environmental tests: IEC 60687 or ANSI C12.20 The memory to record the loading:

Power Line Carrier Module Modem Module RS-485 Module

EM3005 (5Amp) EM3030 (30 Amp)

Communication Interfaces

Specifications

Wirings

Power: 96 ~ 528 VAC, 50 / 60 Hz

Accuracy: 0.5 % (IEC 60687 or ANSI C12.20)

Range: Voltage 96 ~ 528 VAC,

Current:model EM3005: Ib 5A, 2.5 mA ~ 20 A model EM3030: Ib 30A, 30 mA ~ 200 A

Operating Temperature: -40~80 ºC

Time of use ( TOU ): 4 available time zooms applied for different rates

The minimum starting current: 2.5 mA for EM3005, 30mA for EM3030

Electricity supply at any phase: available

Counting KWh under one or two phase electricity: available

Electricity data to be measured and displayed: around 400 items

Communication protocol: ANSI C12.18, ANSI C12.19

Electricity and Environmental tests: IEC 60687 or ANSI

C12.20

The memory to record the loading: 2 MB

Communication software: Programming, Load Profile and Communication in 3 kinds

Automatic calibration: available

Meter constants: programmable

Dimension: 188mm(W) X 235mm(H) X 156mm(D)

Net weight: 2.1Kgs

Page 4: OEM & ODM business are welcome! · Communication protocol: ANSI C12.18, ANSI C12.19 Electricity and Environmental tests: IEC 60687 or ANSI C12.20 The memory to record the loading:

Type 05 - 5 Amp 30 - 30 Amp

Communications 0 – none c – LonTalks power line carrier m – modem 2 – RS-232 4 – RS-485

Function b - basic function of Time-of-Use p - Time-of-Use plus Load Profile function

Software 0 – none 3 – Programming, Load Profile and Communication in 3 kinds

Ordering Code

PSI inc.

Tel: 514-852-1616 Fax: 514-329-0012E-mail: [email protected] site: http://www.psi-qc.com

EM30 - □ □ □ □