Ohaus Corporation19A Chapin RoadP.O. Box 2033Pine Brook, NJ 07058, USA
Ohaus Ruby Compact Jewelry Scalewith Taels
-OPERATING MANUAL-
• For best results, use the scale in the specified optimum operatingtemperature.
• For best accuracy, perform your mass measurements in cleanenvironments, free of electrostatic and magnetic fields, dust and dirt,moisture, vibration and air currents.
• Use your scale with care, gently loading items to be weighed onto thecenter of the pan. Avoiding rough treatment will aid in the life of yourcompact scale.
• Calibration weights are not provided with the scale.
MANUAL.pmd 9/14/2005, 2:51 PM1
2
Battery InstallationThree AA size alkaline batteries are provided.
• Remove the battery cover on the bottom of the scale and place thethree “AA” size alkaline batteries into the compartment as indicated.
• Do not use excessive force or press the weighing pan.
• Re-insert the battery cover.
AC Adapter OperationAC power adapters are available as optional accessories.
• Connect the AC adapter to the power input jack at the rear of the scale.
• Plug the AC adapter into a properly grounded wall outlet.
General Product Features• Power Up Test: When the scale is turned on, all display segments will
appear for approximately 3 seconds before resetting to zero.
• Stable Reading Indication: On the display, a star indicator will appear inthe lower left corner of the display when a stable reading has beenreached.
• Weight Unit Indication: On the display, either g, thk, tsg or trc willappear indicating the weight unit selected.
• Overload: If the applied load exceeds the capacity of the scale, an Ewill appear on the display and the load should be removed immediately.The scale will return to normal operation.
• Zero Function: Values can progressively be added to a sample. Bypressing the On/Off Zero button, the scale display returns to zero. Afteradding additional mass, press On/Off Zero to zero the scale again.Additional mass may be added up to the capacity of the scale.
MANUAL.pmd 9/14/2005, 2:51 PM2
3
• Negative Value: When a load is removed from the scale, any zeroedvalue will be displayed as a negative number. To return to normaloperation, the zeroed value can be cancelled by pressing On/Off Zero.
• Low Battery Indication: The display will show Lo when the batteries areweak and need to be replaced.
• Auto Shut-Off: To extend battery life, the scale will automatically turn offafter approximately 4 minutes if no button press or active weighing isoccurring. This feature is only active with battery operation.
Two Button Keypad• On/Off Zero: Pressing this button turns on the scale. This same button
operates the zero feature when the scale is on. Press and hold thisbutton for three seconds to turn the scale off.
• Unit/Cal: Press this button briefly to change the weighing unit. Thefollowing weight units may be selected: Hong Kong Taels (thk), SingaporeTaels (tsg), Taiwan Taels (trc) or grams (g). Press and hold this button tobegin the calibration process.
CalibrationFor best results, calibrate the scale at regular intervals. This is especiallyimportant if the scale is in use for prolonged periods.
• Pressing and holding the Unit/Cal button starts thecalibration process. The display should show CAL.
• The calibration process can be aborted by turning thescale off.
• Press the On/Off Zero button to capture 0. Thedisplay shows -C- while the scale stores the the zeroload signal.
• The display will show C xxx where xxx is thecalibration weight in grams.
• Place the appropriate calibration weight on theplatform.
• Press On/Off Zero button.
• The display shows -C- while the scale stores thecalibration point signal.
MANUAL.pmd 9/14/2005, 2:51 PM3
4
Accessories Supplied• Three AA size alkaline batteries.
Optional AccessoriesAC Power Adapters: Ohaus Part No.
120V US Plug 90524-66220V Euro Plug 90524-63240V UK Plug 90524-64240V Australian Plug 90524-65
Calibration Masses:200g 51025-16
1050 ml Bowl 80850075Stainless steel weighing pan cover 80850076
• After span capture, the display returns to thenormal weighing mode.
• The message CAL E will appear if the calibrationsteps are not followed or the wrong weight was used.
Specifications JR 300T
Capacity x Readability 300 X 0.1g8.015 X .005thk7.935 X .005tsg8.000 X .005trc
Linearity ±0.1g
Weighing units g, thk, tsg, trc
Calibration User calibration
Stabilization time 3 seconds
Overload indication [ E ]
Underload indication Negative value
Auto shut-off 4 minutes no activity
Optimum operating temperature 64° to 77° F / 18° to 25° C
Weigh pan size L x W (in/cm) 5.75 x 5.25/14.5 x 13.3
Power requirements 3-AA alkaline batteries
Dimensions L x W x H (in/cm) 8.00 x 5.50 x 1.50 / 20.5 x 14.0 x 3.8
Net Weight (lb/kg) 1.0/0.47
g
MANUAL.pmd 9/14/2005, 2:51 PM4
5
Declaration of Conformity We, Ohaus Corporation, declare under our sole responsibility thatthe balance models listed below marked with "CE" are in conformity with the directives andstandards mentioned.
EC Marking EC Directive Applicable Standards73/23/EC EN60950:1992Electrical equipment for usewithin specified voltage limits
89/336/EC EN61326:1997 + A1:1998 + A2:2001Electromagnetic compatibility
Ted XiaPresident
Ohaus CorporationPine Brook, NJ USA
Date: September 15, 2005
Ohaus Corporation, 19A Chapin Road, P.O. Box 2033, Pine Brook, NJ, 07058-2033, USA
Instrument type JR300T
NOTE: This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonableprotection against harmful interference in a residential installation. This equipment generates,uses and can radiate radio frequency energy and, if not installed and used in accordance withthe instructions, may cause harmful interference to radio communications. However, there is noguarantee that interference will not occur in a particular installation. If this equipment doescause harmful interference to radio or television reception, which can be determined by turningthe equipment off and on, the user is encouraged to try to correct the interference by one ormore of the following measures:
-- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.
Urs MüllerGeneral Manager
Ohaus EuropeGreifensee, Switzerland
ISO 9001 RegistrationIn 1994, Ohaus Corporation, USA, was awarded a certificate of registration to ISO 9001 byBureau Veritus Quality International (BVQI), confirming that the Ohaus quality managementsystem is compliant with the ISO 9001 standard’s requirements. On May 15, 2003, OhausCorporation, USA, was re-registered to the ISO 9001:2000 standard.
This Class B digital apparatus complies with Canadian ICES-003.Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada
MANUAL.pmd 9/14/2005, 2:51 PM5
6
LIMITED WARRANTYOhaus compact scales are warranted against defects in materials andworkmanship for a period of 12 months from the date of delivery. Duringthe warranty period, Ohaus will repair, or, at its option, replace anycomponent(s) that prove to be defective at no charge, provided that theproduct is returned, freight prepaid, to Ohaus.
This warranty does not apply if the product has been damaged by accidentor misuse, exposed to radioactive or corrosive materials, has foreignmaterial penetrating to the inside of the product, or as a result of serviceor modification by other than Ohaus. In lieu of a properly returned warrantyregistration card, the warranty period shall begin on the date of shipmentto the authorized dealer. No other express or implied warranty is given byOhaus Corporation. Ohaus Corporation shall not be liable for anyconsequential damages.
Ohaus Corporation19A Chapin RoadP.O. Box 2033Pine Brook, NJ 07058, USATel: (973) 377-9000Fax: (973) 973-944-7177
With offices worldwide.
P/N 71152433 A
Ohaus Corporation 2005, all rights reserved. Printed in China
*71152433*
MANUAL.pmd 9/14/2005, 2:51 PM6
7
Ohaus Corporation19A Chapin RoadP.O. Box 2033Pine Brook, NJ 07058, USA
MANUAL.pmd 9/14/2005, 2:51 PM7
8
MANUAL.pmd 9/14/2005, 2:51 PM8
9
MANUAL.pmd 9/14/2005, 2:51 PM9
10
g
MANUAL.pmd 9/14/2005, 2:51 PM10
11
*71152433*P/N 71152433 A
MANUAL.pmd 9/14/2005, 2:51 PM11
12
Ohaus Corporation19A Chapin RoadP.O. Box 2033Pine Brook, NJ 07058, USA
MANUAL.pmd 9/14/2005, 2:51 PM12
13
MANUAL.pmd 9/14/2005, 2:51 PM13
14
MANUAL.pmd 9/14/2005, 2:51 PM14
15
g
MANUAL.pmd 9/14/2005, 2:51 PM15
16
MANUAL.pmd 9/14/2005, 2:51 PM16
17
OHAUS WARRANTY REGISTRATION
Please complete this registration form and fax or mail to clostest office, see rear page.
________________________________________________________________NAME,
________________________________________________________________ORGANIZATION,
________________________________________________________________TITLE,
_________________________________________________________________ADDRESS,
_________________________________________________________________CITY,
_________________________________________________________________STATE,
_________________________________________________________________POST CODE/ZIP,
_________________________________________________________________TELEPHONE NO.,
_________________________________________________________________MODEL NO.,
_________________________________________________________________PURCHASED FROM,
_________________________________________________________________DATE OF PURCHASE,
MANUAL.pmd 9/14/2005, 2:51 PM17
18
Ohaus Corporation19A Chapin RoadPO Box 2033Pine Brook, NJ 07058-2033Fax: 973-944-7177
Ohaus JapanMettler-Toledo K.K.5F Tokyo Ryutsu Center Annex6-1-1 Heiwajima, Ohta-kuTokyo 143-0006, JapanFax: 9-011 +81-3-5762-0756
Ohaus Korea30th Fl. ASEM Tower159-1, Samsung-dong, Kangnam-kuSeoul, KOREA 135-090Fax: 9-011 +822 6001-3003
Ohaus Australia220 Turner StP.O. Box 173Port Melbourne, Australia 3207Fax:: +61 3 9645 3935
Ohaus China589 Gui Ping RoadShanghai 200233, P.R. of ChinaKent T Xiangun Guo ongHaijian LuFax: +86-21-64853351
Ohaus EuropeHeuwinkelstrasseCH-8606 Nanikon, SWITZERLANDFax: +41-1-944 32 30
Ohaus SEA Sdn BhdUnit 1.02, (1st Floor)Bangunan ElectrosconLot 8 Jalan Astaka U8/84,Bukit Jelutong, 40150 Shah AlamSelangor D.E., MalaysiaFax: +603-7845-3478
Ohaus IndiaAmar Hill, Saki Vihar Road,Powai, Mumbai 400 072, IndiaFax: +22-857 7716
MANUAL.pmd 9/14/2005, 2:51 PM18
19
MANUAL.pmd 9/14/2005, 2:51 PM19
20
P/N 71152433 A
Ohaus Corporation 2005, all rights reserved. Printed in China
Ohaus Corporation19A Chapin RoadP.O. Box 2033Pine Brook, NJ 07058, USATel: (973) 377-9000Fax: (973) 944-7177www.ohaus.com
With offices worldwide.
*71152433*
MANUAL.pmd 9/14/2005, 2:51 PM20