oil and gas pipeline design, maintenance and repair - cu 12 leak detection and scada... · pe 607:...
TRANSCRIPT
![Page 1: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/1.jpg)
١PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Dr. Abdel-Alim HashemProfessor of Petroleum Engineering
Mining, Petroleum & Metallurgical Eng. Dept. Faculty of Engineering – Cairo University
[email protected]@yahoo.com
Part 12: LEAK DETECTION AND SCADA SYSTEM
Oil and Gas Pipeline Design, Maintenance and Repair
![Page 2: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/2.jpg)
٢PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Content• Methods of Detecting a Leak.• Leak Detection Instruments.• Description of Leak Detection Equipment• Recommended Method for Surface Gas Detection
Survey with FI Unit.• Odorants• Follow-up Inspection.• Leak Classification and Action Criteria.
![Page 3: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/3.jpg)
٣PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Methods of Detecting a Leak• Odor.• Vegetation. • Insects (flies, roaches, spiders). • Fungus-like Growth. • Sound. • Unaccounted for Gas. • Soap Solutions. • Leak Detection Instruments.
![Page 4: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/4.jpg)
٤PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
1.Odor• Gas odor is a common and effective indication of a leak• Gas is intentionally odorized so that the average person can
perceive it at a concentration well below the explosive range .• Odorant concentration is generally between 0.5 to 1.0 percent by
volume or as local applicable codes dictate .A report of gas odor should be investigated immediately .
• If a leak is found, the migration pattern of the gas should be determined .
• If an immediate hazard is determined to exist, the hazard potential should be eliminated and the leak repaired immediately .
![Page 5: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/5.jpg)
٥PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
2.Vegetation• Vegetation in an area of gas leakage may improve or
deteriorate, depending on:-1- The soil.2- The type of vegetation. 3- The environment. 4- The climate. 5- The volume and duration of the leak.
• Changes in vegetation may indicate slow below ground leaks.
• A vegetation survey by itself is not an acceptable method of complying with the pipeline safety regulations.
• Leak surveys should be conducted with leak detection equipment.
![Page 6: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/6.jpg)
٦PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
3.Insects (flies, roaches, spiders).
• Insects migrate to points or areas of leakage due to microbial breakdown of some components of gas.
• Some insects like the smell of the gas odorant.
• Heavy insect activity, particularly near the riser, the gas meter, or the regulator, can sometimes indicate a gas leak.
![Page 7: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/7.jpg)
٧PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
4.Fungus-like Growth.• Such growth in valve boxes, manholes, etc., may indicate gas
leakage. • These fungi grow best where there is a lack of oxygen, such as
in a gas leak area. • The color of the growth is generally white or grayish-white
similar to a coating of frost. • All such indications should be investigated with a leak
detection instrument. • Personnel should never enter manholes or other confined
spaces without first testing oxygen levels and gas concentrations.
• Check Occupational Safety and Health Administration (OSHA) regulations concerning confined space entry for further details on this subject.
![Page 8: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/8.jpg)
٨PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
5.Sound.• Listen for leaks.
• A hissing sound almost at: 1- A bad connection. 2- A fractured pipe. 3- A corrosion pit is the usual
indication of a gas leak.
![Page 9: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/9.jpg)
٩PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
6.Unaccounted for Gas.• A possible leak is indicated when an off-peak reading of a
master meter.
• Periodic off-peak checks can be averaged to provide data for comparison in future checks.
• This method may indicate a leak on the system, but will not provide a location for the leak.
• It is also most effective if consumption figures are known for atime period before the leak(s) occurred.
![Page 10: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/10.jpg)
١٠PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
7.Soap Solutions.• A soap solution can pinpoint the location of a leak on:
1-an exposed pipe. 2- On the riser. 3- On the meter.
• The solution is brushed or sprayed on and the location of bubbling indicates leakage.
• When excavating underground piping to investigate a suspected leak location, the pipe should be brushed and completely clean.
• Many leaks are found on the bottom of the pipe.
• A mirror may be used to observe the underside of the pipe.
![Page 11: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/11.jpg)
١١PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Leak Detection Instruments
![Page 12: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/12.jpg)
١٢PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Leak Detection Instruments.• Gas leak indicators are sophisticated instruments that require
regular care, maintenance, and calibration, and should be used by trained personnel.
• Two types are commonly used by the gas industry for surveying and pinpointing leak:
- Bead sensor type detector.- Combustible Gas Indicator (CGI).- Flame Ionization (FI) gas detector.
- PD (Personal Detector) Short Locator.
![Page 13: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/13.jpg)
١٣PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Leak Detection Equipment
![Page 14: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/14.jpg)
١٤PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Description of Leak Detection Equipment
![Page 15: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/15.jpg)
١٥PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Bead sensor type detector• Is most often used for inspecting exposed piping and
appliances to pinpoint leaks on those facilities.
• Bead sensor instruments are not generally used for leak surveys of underground piping.
![Page 16: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/16.jpg)
١٦PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Combustible Gas Indicator (CGI).
• The CGI was designed primarily for use in a confined space. • The CGI (Figure IV-3a & IV-3 b) consists of:
- Meter. - Probe. - Aspirator bulb.• The bulb is pumped by hand to bring a sample of air into the
probe and the instrument. • The CGI is not suitable for above ground surveys. • These instruments must be calibrated for the type of gas in the
system. • The CGI should be calibrated for natural gas for use on a
natural gas system.
![Page 17: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/17.jpg)
١٧PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Figure IV-3a
Combustible Gas Indicator (CGI).
Analogue Driven
![Page 18: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/18.jpg)
١٨PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Figure IV-3b
Combustible Gas Indicator (CGI)
Digital Readouts.
![Page 19: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/19.jpg)
١٩PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Figure IV-4
1% 5% 10% 15%
LIMITS OFFLAMMABILITY
LOWEREXPLOSIVELIMIT- (LEL)
UPPEREXPLOSIVELIMIT- (UEL)
NATURAL GAS-IN-AIR MIXTURE
1- This is an illustration of the lower and upper explosive limits for natural gas2- Typical natural gas is flammable in 4 to 14 percent natural gas in air mixture.
3- In a confined space, a 4 to 14 percent mixture can be explosive.
![Page 20: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/20.jpg)
٢٠PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Combustible gas indicator (CGI)• There is two main applications for outside surveys are:
1- Available Openings. 2- bar holing.
• A bar hole is a small diameter hole made in the ground in the vicinity of gas piping to extract a sample of the ground atmosphere for leak analysis.
• The CGI instruments are also useful in building surveys and in areas within a building, such as heater closets, and other confined areas.
• A CGI should always be used first when entering a building to determine if a hazardous atmosphere is present.
• The cost of a CGI is substantially lower than an FI unit.
![Page 21: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/21.jpg)
٢١PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
The Flame Ionization (FI)• The Flame Ionization (FI) detector uses a hydrogen fuel to power a
small flame in a detector cell.
• A pump or venturi system is used to pass continuous air samples through the detector cell.
• This is detected electronically and displayed on a meter readout.
• FI units are equipped with meters that indicate gas concentrations from 1 Part Per Million (PPM) to 10,000 PPM.
• They are also equipped with audible alarms to alert the operator when there is a meter deflection.
• Leak survey can be done more rapidly with an FI unit than with a CGI using the bar hole method.
![Page 22: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/22.jpg)
٢٢PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Figure IV-5The Flame Ionization (FI)
unit.
This man is checking a gas meter for leaks with a hand-carried FI unit.
![Page 23: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/23.jpg)
٢٣PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
PD (Personal Detector) Short Locator.
• The Model PD Detector acclaimed to be the fastest method known to accurately locate points of electrical contact and insulatingjoints on coated pipelines.
• Unaffected by parallel lines, depths or cover, the survey can often be, in part, conducted from a moving vehicle over the pipe.
• The PD Detector can be used to locate discontinuities in the coating of buried pipelines.
![Page 24: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/24.jpg)
٢٤PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Receiver
Oscillator PD Locator
![Page 25: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/25.jpg)
٢٥PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
PD (Personal Detector) Short Locator.
• The depth of the pipe or cable can be accurately determined without the usual bending or kneeling.
• First locate center of the pipe or line "A" by crossing the pipein a sweeping motion.
• A "null" (no signal) will mark the center of the pipe.
• Mark this location "A", moving 90o from the pipe with bubble centered in 45o angle gauge and holding the probe tip close to the ground until another "null"- "B" is detected.
• This distance from "B" to "A" less ½ of the outside diameter of the pipe will be the depth of the buried pipe as in Figure (I).
![Page 26: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/26.jpg)
٢٦PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Figure (I)
![Page 27: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/27.jpg)
٢٧PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Recommended Method for Surface Gas Detection Survey with FI Unit
(Natural Gas System Only)
![Page 28: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/28.jpg)
٢٨PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Recommended Method for Surface Gas Detection Survey with FI Unit (Natural Gas System Only)
• The ability of the gas to vent at the ground surface is critical for the success of a surface survey with an FI unit.
• FI is not to be used when the ground is frozen. • A sampling of the atmosphere , the services should be made at
ground level or at no more than 2 inches above the ground surface. • In areas where the gas piping is under pavement, samplings , curb
lines & available ground surface openings Such as:-1- manholes 2- catch basins 3- sewers 4- Telephone duct openings. 5- Fire & traffic signal boxes 6- cracks in the pavement
![Page 29: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/29.jpg)
٢٩PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Figure IV-7
• This figure shows leaking gas following the sewer line into the home, after leaking at the service tee. Natural gas can migrate in this manner.
1st FLOOR
BASEMENT
SINKSTOOL GAS
METER
SEWER LINE
WATER LINE
STREET
GASSERVICE
GAS LEAKNATURAL GAS
GAS PIPELINE
STREETMANHOLE
COVER
GAS
STREET CURB
GASLINE
SEWER LINE
STORMSEWER DRAIN
SEWER LINE
STREET CURB
Figure IV-8
![Page 30: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/30.jpg)
٣٠PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Odorants
![Page 31: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/31.jpg)
٣١PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Types of Odorants• Most odorants used in the United States are:
a) Mercaptans. b) Mercaptan sulfide blends.
• The only other odorant in wide use is cyclic sulfide (thiophane), which is mainly used in gas systems containing natural odorants.
• The human sense of smell is very discerning and can detect mercaptans at a concentration of only 1 Part Per Billion (PPB).
• The sulfur content of the odorants in the gas stream can be measured by gas analysis, if there is sufficient odorant.
• The main types of detectors are:-1- Odor concentration meters.2- Titrators.3- Gas chromatographs.
![Page 32: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/32.jpg)
٣٢PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Odorization Equipment
Figure IV-10
• The figures shows equipment which odorizes the gas.
ODORANT LEVEL
SINGLE-UNIT WICK ODORIZER
GAS FLOW
Figure IV-9
![Page 33: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/33.jpg)
٣٣PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Figure IV-12A picture of an odor testing instrument.
Figure IV-13This man is conducting a sniff test using an odor testing instrument.
![Page 34: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/34.jpg)
٣٤PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Follow-up Inspection
![Page 35: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/35.jpg)
٣٥PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Follow-up Inspection
• The adequacy of leak repairs should be checked before backfilling.
• The perimeter of the leak area should be checked with a CGI.
• a follow-up inspection should be made as soon as practical after allowing the soil atmosphere to vent and stabilize.
• OPS suggests follow-up inspection within 24 to 48 hours.
![Page 36: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/36.jpg)
٣٦PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
A method to remember when investigating gas leaks and determining it as follows:
• Where is the gas ? (Use a detector to confirm gas is present)
• How much is there ?(Take readings on the CGI)
• Extent of the spread? (Determine the migration pattern)
• Relation to other structures ?(Is gas detected in or near buildings or in manholes?)
• Evaluate/evacuate? (Classify the leak and take appropriate action)
![Page 37: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/37.jpg)
٣٧PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Leak Classification and Action Criteria
![Page 38: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/38.jpg)
٣٨PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Leak Classification and Action Criteria
• There is three grades of classification and action criteria:
1- Grade-12- Grade-23- Grade-3
![Page 39: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/39.jpg)
٣٩PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Grade-1
• A leak that represents an existing or probable hazard to persons or property, and requires immediate repair or continuous action until the conditions are no longer hazardous.
•Requires prompt action to protect life and property.
![Page 40: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/40.jpg)
٤٠PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Grade-2
• A leak that is recognized as being non-hazardous at the time of detection, but justifies scheduled repair based on probable future hazard.
• Leaks should be repaired or cleared within one calendar year, but no later than 15 months from the date the leak was reported.
![Page 41: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/41.jpg)
٤١PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Grade-3
• A leak that is non-hazardous at the time of detection and can be reasonably expected to remain non-hazardous.
• These leaks should be re-evaluated during the next scheduled survey, or within 15 months of the date reported.
![Page 42: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/42.jpg)
٤٢PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Conclusion:1- There is Methods of Detecting a Leak in Pipes.2- Leak Detection Instruments Must be Apply
Immediately.3- Can Detect any leak in pipes by Leak Detection
Equipment.4- Surface Gas Detection Can Be Detected By Survey with
FI Unit.5- Can easily Detect gas leaking by Odorants.6- Follow-up Inspection is Very important.7- There is Classification for Leak .
![Page 43: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/43.jpg)
٤٣PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
SCADA
Supervisory Control And Data Acquisition
نظام المراقبة والتحكم وجمع البيانات
WHAT IS SCADA ?ما هـو نظـــــام االســــكادا
![Page 44: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/44.jpg)
٤٤PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
ما هو نظـام االســكادا؟ االسكادا هى نظام تكنولوجي يمكن مستخدمها من جمع بيانات من مواقع ذه بعيدة ومراقبة تشغيل هذه المواقع وإرسال أوامر التشغيل للتحكم فى ه
غلق أو Set Pointالمواقـع مثل غلق أو فتح الصمامات أو تغـيير ال أشخاص وجود إلي الحاجة دون وهذا ، الطوارئ حالة فى بالكامل المحطة.فى ظروف التشغيل العادية المواقع هذه فى للتشغيل
What is SCADA?SCADA is the technology that enables a user to collect data from distant facilities , supervise the operation and send control instructions to those facilities as closing or opening valves ,changing set points or shutdown in case of emergency , so there is no need to assign operators to those facilities in normal operating conditions.
![Page 45: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/45.jpg)
٤٥PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
-:IMPORTANCE OF SCADA-:أهمية نظام االسكادا
إمكانية المراقبة والتحكم فى شبكة الغاز بكل تفاصيلها والتى يمكن -. أن تمتد إلى آالف الكيلومترات
- The ability of monitoring and control the gas network with its details whichcan be extended to thousands of kilometers.
.تحليل بيانات التشغيل وتخزينها لمدد طويلة -
- Operational data analyses and storage for long periods ( historical).
.إعداد تقارير التشغيل اليومية والدورية-
- Operational data daily and periodically reporting.
.تسجيل األحداث وأوامر التشغيل وآذلك اإلنذارات -
- Logging of selected events and operator actions and warning alarms.
![Page 46: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/46.jpg)
٤٦PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
- Remote diagnostics and upgrading for RTU’s.
- The ease of upgrading or reconfiguring the system as adding or omitting
gas pipelines, gas stations or even the signals transmitted from stations
to dispatch center by persons who have this permission through an
engineering terminal without operational interruption.
![Page 47: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/47.jpg)
٤٧PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
SCADA
SupervisionMonitoring of operation parameters such as press., temp., flow,…..
Data AcquisitionRemotely using telecomm. Networks to connect control sites to control centers.
ControlIssuing control commands to fulfill operation demands.
![Page 48: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/48.jpg)
٤٨PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Supervisory Control And Data Acquisition SystemFor The Egyptian National Gas Grid
Is integrated system used to remotely monitor and control different gas activities in Egypt and is known as SCADA for abbreviation
![Page 49: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/49.jpg)
٤٩PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
To SCADA
To SCADA
PT
To SCADA
R & M Station
PT TT
To SCADA
T. Box
Instrumentation cables
RTU
Control panel
To SCADA
To SCADA
To SCADA
To SCADA
To SCADA
8
8
![Page 50: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/50.jpg)
٥٠PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Operation Philosophy
![Page 51: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/51.jpg)
٥١PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
• Each local control center collects the information of control sites in its geographical area and perform local monitoring.
• This information is transmitted to the main control center for central monitoring.
• Control is done centrally from the main control center by sending the control information to local centers.
• In case of failure of a local control center the main control center takes over its role until it comes back and then updates it with lost data during the failure period.
• The main control center is designed in redundant configuration to ensure reliable and secure control over the grid, only a force major could cause the main control centre to fail.
• In case of main control center failure the emergency control center takes over until it comes back and then updates it with
![Page 52: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/52.jpg)
٥٢PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Applying this operation philosophy guarantees continuous and safe control over the gas grid
![Page 53: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/53.jpg)
٥٣PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
System Objective
![Page 54: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/54.jpg)
٥٤PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
The main objective of the system is to protect the huge investments in the national gas grid via:
• Providing remote monitoring and control over the whole pipelinesnetwork.
• Proposing operation scenarios for different operating circumstances and in emergency situations.
• Leak and break detection in pipelines network.
• Facilitate decision support systems.
• Integration with other application such as gas accounting and billing system.
• Remote administration and maintenance of different system components.
• Telecomm systems are utilized to provide voice and data communications between all system’s sites independently of third-party service providers
![Page 55: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/55.jpg)
٥٥PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Gas Grid InformationThe System Serves (about) :
Gas Grid Length: 3000 KmGrid Capacity: 100 SMCM/DayBulk Consumers: 250Gas Fields: 15
![Page 56: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/56.jpg)
٥٦PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Components of National Components of National Gas Grid Gas Grid SCADASCADA SystemSystem
![Page 57: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/57.jpg)
٥٧PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
The system consists of:• Remote Terminal Units RTUs• Control Centers• Telecomm networks• Software packages
![Page 58: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/58.jpg)
٥٨PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
FirstRemote Terminal Units
![Page 59: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/59.jpg)
٥٩PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
The RTU Is a special computer designed to process data between control sites and local control centers
![Page 60: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/60.jpg)
٦٠PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
SecondControl Centers
![Page 61: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/61.jpg)
٦١PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
4 Control centers cover geographically the whole gas grid
AlexCairo
Suez
Delta)
![Page 62: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/62.jpg)
٦٢PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
The main control center is located in Cairo and is responsible for monitoring and control of the national gas grid. The center is designed in redundant configuration for reliable operation. It takes the role of local control centers in case of failure, and is consists of:
![Page 63: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/63.jpg)
٦٣PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Local control centers are located in Delta, Alexandria, Suez, and Cairo. Each control center gathers the operation data for its local sites and perform control actions, then it transmit this data to the main control center.
![Page 64: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/64.jpg)
٦٤PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Emergency control center is designed to take over the role of the main control center in case of emergency or failure.
![Page 65: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/65.jpg)
٦٥PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
ThirdTelecommunication
Networks
![Page 66: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/66.jpg)
٦٦PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
An integrated high speed digital telecomm. Network covers the whole gas grid, while providing voice and data services between grid sites.
![Page 67: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/67.jpg)
٦٧PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Primary digital microwave network working in the 7 Giga band, indicated in red color and is used for data transmission between control centers.
![Page 68: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/68.jpg)
٦٨PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Optical fiber network and is usually installed with recent pipelines. It is indicated in yellow colors. Fiber optics network is used to transmit data between control centers and also transmit operation information of the pipeline.
![Page 69: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/69.jpg)
٦٩PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Secondary digital microwave network consisting of 4 local networks covering the whole gas grid and is working in the 2.4 Giga band. This network is used to connect production, consumers, and dispatching sites to the local control center.
![Page 70: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/70.jpg)
٧٠PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
FourthApplication Software Packages
![Page 71: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/71.jpg)
٧١PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
Application Software Packages
• SCADA software package.• Network management software packages.• Gas grid simulation software is doing grid
analysis and accordingly proposing operation scenarios in different circumstances. It detects leak and line break, also predict their places. It performs other functions that ensure GASCO high security measures.
![Page 72: Oil and Gas Pipeline Design, Maintenance and Repair - cu 12 Leak detection and SCADA... · PE 607: Oil & Gas Pipeline Design, Maintenance & Repair ٢ Content • Methods of Detecting](https://reader031.vdocument.in/reader031/viewer/2022013008/5c95ce0709d3f29c7b8d59fe/html5/thumbnails/72.jpg)
٧٢PE 607: Oil & Gas Pipeline Design, Maintenance & Repair
References:-• Leak Detection, 49 CFR, Part 192.
• From Net:
-www.caltechindia.com