oil heaters
DESCRIPTION
DC Oil HeaterTRANSCRIPT
20 Customer Support: (509) 536-8660 www.hotstart.com
Oil Heaters
Use a thermostat with all lube oil heaters to protect the oil from overheating if the heater is energizedwhile the engine is hot or running. Lube oil heaters must always be installed in the sump with the entireheater submerged below the oil level at all times. See page 21 for remote thermostat part numbers.
OilCapacity
WeathertightHeater Only
WeathertightWith Thermostat
Class 1, Group DHaz. LocationsHeater Only
Volts Watts Amps Watts/SqInch
3/8” N.P.T. THREAD WITH A 2 1/8” PROBE LENGTH
2 qts (2L)or Less
OW005100-000OW005200-000
——
——
120240
5050
.4
.220.020.0
1/2” N.P.T. THREAD WITH A 4” PROBE LENGTH
2 - 6 qts2 - 5.7L
OW212100-000OW212200-000
OW2121XX-000OW2122XX-000
OE212100-000OE212200-000
120240
125125
1.0.5
24.624.6
3/4” N.P.T. THREAD WITH A 5” PROBE LENGTH
1 - 5 gal3.8 - 19L
OW415100-000OW415200-000
OW4151XX-000OW4152XX-000
OE415100-000OE415200-000
120240
150150
1.3.6
14.614.6
5 - 15 gal19 - 57L
OW430100-000OW430800-000OW430200-000
OW4301XX-000OW4308XX-000OW4302XX-000
OE430100-000OE430800-000OE430200-000
120208240
300225300
2.61.11.2
29.322.029.3
1” N.P.T. THREAD WITH A 5 1/4” PROBE LENGTH
1 - 5 gal3.8 - 19L
OW615100-000OW615200-000
OW6151XX-000OW6152XX-000
OE615100-000OE615200-000
120240
150150
1.3.6
10.710.7
5 - 15 gal19 - 57L
OW630100-000OW630800-000OW630200-000
———
OW6301XX-000OW6308XX-000OW6302XX-000
———
OE630100-000OE630800-000OE630200-000OE630700-000OE630300-000OE630400-000
120208240277380480
300375300265300300
2.61.81.21.01.0.6
21.428.021.419.021.421.4
15 - 30 gal57 - 113L
OW650100-000OW650800-000OW650200-000OW650700-000
———
OW6501XX-000OW6508XX-000OW6502XX-000OW6507XX-000
———
OE650100-000OE650800-000OE650200-000OE650700-000OE650300-000OE650400-000OE650500-000
120208240277380480575
500450500400500500500
4.12.22.01.41.31.00.8
35.733.035.730.035.735.735.7
C US
OilCapacity Volts Watts
.5” NPT with4” ProbeLength
.75” NPT with4 7/8” Probe
Length
1” NPT with5 3/8” Probe
LengthAmps
Watts PerSquareInch
2 Quartsor Less
1224
7575
OW207900-012—
OW407900-012OW407900-024
——
6.33.1
1/2” are all 14.7 WSI3/4” are all 7.3 WSI
2 to 6Quarts 24 125 OW212900-024 — — 5.2 24.6 WSI
1 to 5Gallons
1224
150150
——
OW415900-012OW415900-024
OW615900-012OW615900-024
12.56.3
3/4” are all 14.6 WSI1” are all 10.7 WSI
5 to 15Gallons
1224
300300
——
—OW430900-024
OW630900-012OW630900-024
25.012.5
3/4” are all 29.3 WSI1” are all 21.4 WSI
15 to 30Gallons 24 500 — — OW650900-024 20.8 35.7 WSI
NOTES: Weathertight models are furnished with a 4 ft. oil and heat resistant power cord - no plug.Class 1, Group D heaters are furnished with 18” of lead wire for connection to the powerleads in an approved splice box.
To specify temperature range ofthermostat, insert code fromchart in place of the XX in modelnumber.
Example:
Desired Temp. Range 80° - 100°FModel Number: OW2121XX-000Order as: OW212108-000
Temperature RangeCode
ON OFF
60°F (16C)
80°F (27C)
100°F (38C)
80°F (27C)
100°F (38C)
120°F (49C)
06
08
10
See p21 for remote thermostatassembly part numbers
12 Volt and 24 Volt DC oil heaters can be powered directly from the battery, but will drain the battery veryrapidly unless charged by an alternator or generator.
DC Oil Heaters12V and 24V
-
+
12 or 24VDC
DIT COIL
C1
C1 C1
Magnetic Contactors
Oil Heater
When used with a thermostatcontrol, all DC oil heaters mustuse a DC relay
12 VOLT/24 VOLT DCCONTROL BOXES
25 AmpsMaximum
12V24V
JBMC330DC-12VJBMC330DC-24V
oil heater with y-cord and remotethermostat
21Customer Support: (509) 536-8660 www.hotstart.com
Heater only
Class 1, Group DWeathertightFor Hazardous Locations, Heater only
6.54.00
Probe Depth
.50 Dia.
1/2" NPT
1 3/8 Std. Hex1-14 UNS
C US
6.75.25
Probe Depth
1" Dia.
1" NPT1 3/8 Std. Hex
1-14 UNS
6.45.00
Probe Depth
3/4 Dia.
3/4" NPT
1 3/8 Std. Hex
1-14 UNS
REMOTE THERMOSTATS for OIL HEATERS
Weathertight Class I, Group DTemprature Range
ON OFFSensingUnit Thread Size
DIT68
DIT810
DIT1012
DIT1214
DIT68EP
DIT810EP
DIT1012EP
DIT1214EP
60°F (16C) 80°F (27C)
80°F (27C) 100°F (38C)
100°F (38C) 120°F (49C)
120°F (49C) 140°F (60C)
LSU6
LSU8
LSU10
LSU12
.5” NPT
.5” NPT
.5” NPT
.5” NPT
Switch Capacity
120V - 15amp
208V - 10amp
240V - 10amp
277V - 10amp
12V DC
24V DC
PilotDutyOnly}
Weathertight Class I, Group D