Oldcastle
COX WICKENBURG STC
US HIGHWAY 60 AND
FLYING E RANCH ROAD
WICKENBURG, ARIZONA
BUILDING LOCATION SHOWN FOR REFERENCE ONLY
SS
CKT 16
CKT 10
CKT 12
CKT 10
CKT 10
CKT 12
CKT 12
CKT 12
CKT 14
CKT 16
CKT 16
CKT 18 CKT 18
S
T
T
T
SS
T
SS
CKT 16
CKT 10
CKT 12
CKT 10
CKT 10
CKT 12
CKT 12
CKT 12
CKT 14
CKT 16
CKT 16
CKT 18 CKT 18
S
T
T
T
SS
T
7600 East Orchard Road, Suite 250-S
Greenwood Village, CO 80111-2518
tel: 303.796.6000 Fax: 303.796.6099
www.mkkeng.com
Mechanical, Electrical & Energy Consultants
W:\01-C
O\2015.01.0205 O
ldcastle P
recast S
ervices W
ickenburg, A
Z C
om
m S
ite\D
WG
S\E
1 - G
RO
UN
DIN
G P
LA
N.dw
g
Sep 17, 2015 3:01pm
- tupton
PANEL 'MPB-1' SCHEDULE AND ELECTRICAL LOAD CALCULATIONS
USE AND/OR AREA SERVED
208Y/120V 30 4W
11
TOTAL AMPS PER PHASE
TOTAL WATTS PER PHASE
25
29
27
21
23
19
15
17
13
26
28
44504
214.3
SPACE
12
16
14
18
20
24
22
USE AND/OR AREA SERVED
MPB-1
SPACE
(THHN)
WIRE SIZE
PANEL: MOUNTING:QONTYPE:
3
7
9
5
C/B
NO.
1
CIR
NO.
CIR
10
LOAD
SURFACE
0 A 0 B
8
4
6
C/B
2
400AMAINS:
(THHN)
WIRE SIZE
10,000 A.I.C.
0 C
PANEL 'L1' SCHEDULE AND ELECTRICAL LOAD CALCULATIONS
11
TOTAL WATTS PER PHASE
LOAD CALCULATED AT 5 AMPS
TOTAL AMPS PER PHASE
**
25
29
27
21
23
19
17
15
13
26
28
30
40
18
20
24
22
3
12
16
14
L1
USE AND/OR AREA SERVED
WIRE SIZE
(THHN)
PANEL: MOUNTING:QOTYPE:
3
7
9
5
NO.
C/B
1
CIR
SURFACE
0 A 0 B
LOAD
4
6
8
10
2
NO.
CIR
0 C
C/B
A/C UNIT / HEATER #2
(THHN)
WIRE SIZE
MAINS:
USE AND/OR AREA SERVED
10,000 A.I.C.
30
32
34
36
38
40
42
31
33
35
37
39
41
3
200
3Ø
PANEL 'L1'
200A MLO240Y/120V 30 4W
A/C UNIT / HEATER #1
3
40
#8
#8
3
20
#12
SURGE SUPPRESSOR
45136 44344
217.4 213.6
LOAD x 1.25 FOR CONTINUOUS
*
CEILING LIGHT (GROUP 1) *
15
1
#14
876
CEILING LIGHT (GROUP 2) *
1
15
#14
876
15
1
#14
EXTERIOR LIGHT
84
SMOKE DETECTORS
1
15
#14
168
DUPLEX OUTLETS (GROUP #1)
1
15
#14
540
720
DUPLEX OUTLETS (GROUP #2)
15
1
#14
G.F.I. OUTLET
20
1
#12
180
540
DUPLEX OUTLETS (GROUP #3)
15
1
DUPLEX OUTLETS (GROUP #4)
1
15
360
3
20
#12
PHASE FAILURE
4982
4982
4982
4982
4982
4982
#14
#14
33216
33216
33216
TWISTLOCK RECEPTACLE #1
2
50
#6
TWISTLOCK RECEPTACLE #2
2
50
#6
EXISTING
EXISTING
7600 East Orchard Road, Suite 250-S
Greenwood Village, CO 80111-2518
tel: 303.796.6000 Fax: 303.796.6099
www.mkkeng.com
Mechanical, Electrical & Energy Consultants
W:\01-C
O\2015.01.0205 O
ldcastle P
recast S
ervices W
ickenburg, A
Z C
om
m S
ite\D
WG
S\E
2 - E
LE
CT
RIC
AL D
ET
AILS
.dw
g
Sep 17, 2015 3:02pm
- tupton
W
IC
K
E
N
B
U
R
G
W
A
Y
(U
S
H
W
Y
6
0
)
STATE
LAND
PARCEL
505-41-007 D
OLD CASTLE EQUIPMENT
BUILDING 25'-4 x 31'-4
(794 SQ. FT.)
EXISTING
SIGNS
EXISTING
ROAD SIGN
MASONRY SCREEN WALL & GATE.
SEE SHEET S-1 FOR DETAILS.
F
L
Y
I
N
G
R
A
N
C
H
R
O
A
D
1
2
.0
'
NEW GRAVEL
SURFACING
Δ=37°56'39"
R=368.27'
L=243.89'
1
1
1
2
3
4
5
6
7
8
6
6
6
6
FOUND BRASS CAP FLUSH
STAMPED 13941 NPM
FOUND BRASS CAP FLUSH
STAMPED 13941 NPM
S
1
2
°
5
1
'2
3
" W
3
4
3
.7
7
'
F
E
N
C
E
IS
0
.4
1
'N
O
R
T
H
O
F
B
O
U
N
D
A
R
Y
L
IN
E
2357.5 F.F.
2
6
.5
'
10.0' TYP.
3 SIDES
PRECAST GENERATOR
PAD BY OLDCASTLE
1
5
.0
'
4
.0
'
3
0
.2
5
'
4' WIDE SOLID GATE
SELECTED BY CONTRACTOR
4' WIDE - 6"
THICK
CONCRETE
WALK
REMOVE EXIST FENCE.
INSTALL NEW 12' WIDE
METAL GATE SELECTED BY
CONTRACTOR
57.2
5
7
.
2
5
7
5
7
5
7
5
7
5
6
5
6
5
6
5
4
.
5
5
4
.
5
5
6
5
6
.
5
5
6
.5
5
6
.5
5
6
.5
4
:1
4:1
5
6
5
6
5
5
20
SCALE: 1" = 20'
0 10 40 80
NORTH
LEGEND
PROPERTY LINE
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
EXISTING FENCE
EXISTING WATER LINE
NEW RETAINING WALL
NEW BUILDING LOCATION
EXISTING SIGNS
EXISTING SEWER LINE
NEW CONTOUR
NEW GRAVEL SURFACING
SPOT ELEVATION
99.53
FIN. FLR. ELEV.
99.28 F.F.
30 29
FLOW ARROW
TREE TABLE
SIZETREE TYPETREE NO.
MESQUITE1 12"Ø
MESQUITE2 10"Ø
MESQUITE3 16"Ø
MESQUITE4 18"Ø
MESQUITE5 24"Ø
TREE6 12"Ø
JOSHUA TREE7 24"Ø
TREE8 24"Ø
TREE9 24"Ø
7600 East Orchard Road, Suite 250-S
Greenwood Village, CO 80111-2518
tel: 303.796.6000 Fax: 303.796.6099
www.mkkeng.com
Mechanical, Electrical & Energy Consultants
AN
DE
RS
ON
&
H
AS
TIN
GS
CO
NS
UL
TA
NT
S
Jo
b N
o. 0
60
-1
5-2
24
7
SUBGRADE
COMPACTED
NONWOVEN POLYPROPYLENE
N.T.S.
LANDSCAPE FABRIC
SIZE 56 OR 57 CRUSHED
GRADING C OR D
AGGREGATE (100% ANGULAR FACE)
4" THICK AASHTO M-147
AGGREGATE BASECOURSE
2" THICK AASHTO M-43
GENERAL NOTES:
1. TOP SOIL SHALL BE SALVAGED AND STOCKPILED FROM ALL AREAS OF
EMBANKMENT AND EXCAVATION. TOPSOIL SHALL BE REPLACED ON
FINISHED SLOPES THAT DO NOT RECEIVE GRAVEL SURFACE. CLEAR AND
GRUB EXISTING TREES AND SHRUBS FROM WORK AREA.
2. CONSTRUCT BUILDINGS TO THE FINISHED LINES AND GRADES SHOWN ON
THE PLANS. !T SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO IMPORT
FILL MATERIAL OR REMOVE AND DISPOSE OF EXCESS EXCAVATION
MATERIAL AS NECESSARY.
3. AREAS TO RECEIVE GRAVEL SURFACING ARE TO BE SCARIFIED TO A DEPTH
OF 8 INCHES AND COMPACTED TO 95% STANDARD PROCTOR DENSITY
(ASTM D-698) AT ± 1 1/2% OPTIMUM MOISTURE CONTENT. THE SUBGRADE
SHALL BE PROOFROLLED IN THE PRESENCE OF THE GEOTECHNICAL
ENGINEER TO IDENTIFY SOFT SPOTS.
4. EXISTING VERTICAL AND HORIZONTAL CONTROL POINTS SHALL NOT BE
DISTURBED. !T SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
RELOCATE ANY DISTURBED CONTROL POINTS.
5. ALL DISTURBED AREAS NOT RECEIVING GRAVEL SURFACING SHALL BE
SEEDED AND MULCHED IN ACCORDANCE WITH ARIZONA STANDARD
SPECIFICATIONS FOR ROAD & BRIDGE CONSTRICTION.
6. EXISTING TOPOGRAPHY TAKEN FROM SURVEY PERFORMED AUGUST
2015 BY SUPERIOR SURVEYING.
8. THE CONTRACTOR SHALL CONTACT ALL APPROPRIATE UTILITY COMPANIES
PRIOR TO BEGINNING ANY CONSTRUCTION. CONTRACTOR SHALL BE
RESPONSIBLE FOR LOCATING ANY EXISTING UTILITY (INCLUDING DEPTHS)
WHICH MAY CONFLICT WITH THE PROPOSED CONSTRUCTION. ALL EXISTING
UTILITIES SHALL BE PROTECTED FROM DAMAGE BY THE CONTRACTOR.
9. ALL ITEMS SHOWN ON THE PLANS AS EXISTING ARE SHOWN IN
APPROXIMATE LOCATION ONLY. THE ACTUAL LOCATION MAY VARY FROM
THE PLANS, ESPECIALLY IN THE CASE OF UNDERGROUND UTILITIES.
WHENEVER CONTRACTOR DISCOVERS A DISCREPANCY IN LOCATION, HE
SHALL CONTACT ENGINEER IMMEDIATELY.
10. CAUTION : OPERATING COAXIAL CABLE CAN BE DAMAGED BY HEAVY
WHEEL LOADS. AT LOCATIONS WHERE HEAVY CONSTRUCTION
EQUIPMENT WILL BE CROSSING, THE CONTRACTOR SHALL PROVIDE
TEMPORARY GRANULAR FILL MATERIAL, AT LEAST 12 INCHES DEEP, OVER
THE CABLE FOR ADDITIONAL PROTECTION.
11. BENCHMARK: 2" MARICOPA COUNTY ALUMINUM CAP FLUSH STAMPED "T7N
R5W
1
4
S8S17 2005 37174", BEING THE SOUTH QUARTER CORNER OF
SECTION 8, HAVING AN AELEVATION OF 2360.871 FEET (NAVD88), MARICOPA
COUNTY DEPARTMENT OF TRANSPORTAION DATUM.
12. AREAS DISTURBED BY NEW CONSTRUCTION TO BE SEEDED AND MULCHED
IN ACCORDANCE WITH TOWN OF WICKENBURG AND MARICOPA COUNTY
REQUIREMENTS.
TYP. GRAVEL SURFACING SECTION
(NO ROUND RIVER ROCK ALLOWED)
8" CMU REINFORCED WITH #5
@ 24" VERTICAL, FULL HEIGHT.
GROUT CELLS WITH REINF.
BARS FULL HEIGHT. GROUT
ALL CELLS SOLID IN BOTTOM
(4) COURSES. ALL VERTICAL
REINFORCING BARS ARE TO
BE POSITIONED IN CENTER OF
WALL.
STD. DUR-O-WAL @
8" HORIZ. TYPICAL
#5 x DOWELS TO
MATCH VERT. REINF.
(3'-0 PROJECTION)
BOND BEAM WITH
(2) # 5 CONT.
VA
RIE
SV
AR
IE
S
NOTE: REFER TO PHOTO
1, THIS SHEET, FOR CMU
PATTERN AND FINISH
1'-0
"
(4) #5 CONT. TOP
AND BOTTOM
3'-3"
8"
EQ.EQ.
1
2
" = 1'-0"MASONRY SCREEN WALL
TYPICAL DETAILS
NOTE:
1. REFER TO CIVIL DRAWINGS FOR SCREEN WALL LOCATIONS
AND GRADE ELEVATIONS.
VA
RIE
S
8"
10
'-8
"
(1
0'-0
" A
LO
NG
E
AS
T W
AL
L IF
F
OO
TIN
G IS
RA
IS
ED
A
T C
ON
TR
AC
TO
R'S
O
PT
IO
N)
SEE CIVIL FOR GRADE
ELEVATION
T.O. MASONRY WALL
EL. = 2364.5'
T.O. FOOTING
EL. = 2353.83'
#4 @ 18" TOP
AND BOTTOM
T.O. SOLID GROUTED
CMU
2'-8
"
NOTE: PROVIDE 8"x16" DRAIN OPENING
IN BOTTOM OF SCREEN WALL AT EACH
CORNER (4 LOCATIONS). PROVIDE
STANDARD COPPER SCUPPER LINER
OR APPROVED ALTERNATIVE.
NOTE: TOP OF FOOTING MAY BE
RAISED ALONG EAST WALL TO
2354.5' AT CONTRACTOR'S OPTION
(EAST WALL ONLY)
8" M
IN
.
25'-4"
2
S-1
1
S-1
2'-6
"
2'-6"
1
4
" = 1'-0"
FOUNDATION PLAN
PLAN NOTES:
1. CONCRETE FOOTINGS TO BEAR ON UNDISTURBED NATIVE GRANULAR SOILS OR PROPERLY
COMPACTED ENGINEERED FILL, AS APPROVED BY THE GEOTECHNICAL ENGINEER.
2. PRECAST CONCRETE SLAB TO BEAR ON A 4" MINIMUM GRAVEL LAYER OVER NATIVE SOILS OR
PROPERLY COMPACTED ENGINEERED FILL, AS APPROVED BY THE GEOTECHNICAL ENGINEER..
3. REFER TO SHEET C-1 FOR BUILDING LOCATION ON SITE.
2'-0" 2'-0"
PRECAST CONCRETE
STOOP BY OLDCASTLE
PRECAST CONCRETE
STOOP BY OLDCASTLE
31
'-4
"
2'-6"
2'-6
"
1
S-1
1
S-1
2
S-1
1
S-1
PRECAST BUILDING
FOUNDATION
5'-2" 6'-0" 5'-2"
1
2
" = 1'-0"SECTION 1
#4 STIRRUPS @ 12", TYP.
(3) #6 CONT. TOP
AND BOTTOM, TYP.
2'-6"
4"
COMPACTED GRAVEL
FILL, TYPICAL
PRECAST BUILDING
TIE DOWN, CONNECTION TO
PC SHELTER AND LOCATION
BY PRECAST MFR.
1
2
" = 1'-0"SECTION 2
(2) #6 CONT. TOP
AND BOTTOM, TYP.
#4 STIRRUPS @ 16"
PRECAST BUILDING
2'-0"
2'-0
" M
IN
.
BUILDING JOINT
1'-6
" M
IN
.
TY
P.
4"
2'-0
"
SLUMPSTRENGTH
ALL UNLESS
OTHERWISE
SPECIFIED
EXTERIOR
FLATWORK
B
TYPE USE
A
4500 NW 0.45 3-5
TYPE
CONC.
4000
(1)
NW
(2)
RATIO
W/C
-
(4)
3-5
(5)
4-8
WRA
.75"
4-8
(7)
AIR
-
(6)
TURES
ADMIX-
.75"
SIZE
AGGR.
MAX.
STRUCTURAL GENERAL NOTES
1. DESIGN CODES:
A. INTERNATIONAL BUILDING CODE (IBC 2006), AS ADOPTED BY THE TOWN OF WICKENBURG.
B. REFERENCE IBC CHAPTER 35 FOR ADDITIONAL CODES USED IN DESIGN (ASCE/SEI 7-05, AISC 13th
EDITION, ACI 318-05, ETC.)
2. DESIGN LOADS (CORRESPONDING TO CRITERIA SPECIFIED BY OLDCASTLE PRECAST & MEETING OR
EXCEEDING TOWN OF WICKENBURG CRITERIA):
A. ROOF:
1. MINIMUM UNIFORM LOAD . . . . . . . . . . . . . . . . . . 20 psf.
D. WIND:
1. BASIC WIND SPEED (3 SECOND GUST) . . . . . . 90 mph.
2. EXPOSURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C .
3. IMPORTANCE FACTOR . . . . . . . . . . . . . . . . . . I
W
= 1.15.
a) OCCUPANCY CATEGORY . . . . . . . . . . . . . . . III.
E. SEISMIC:
1. SPECTRAL RESPONSE ACCELERATIONS: S
S
= 0.215.
S
1
= 0.068.
2. SPECTRAL RESPONSE COEFFICIENTS: S
DS
= 0.172.
S
D1
= 0.078.
3. IMPORTANCE FACTOR . . . . . . . . . . . . . . . . . . . I
E
= 1.25.
a) OCCUPANCY CATEGORY . . . . . . . . . . . . . . . III.
4. SITE CLASS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C.
5. DESIGN CATEGORY . . . . . . . . . . . . . . . . . . . . . B.
6. BASIC FORCE RESISTING SYSTEM . . . . . . . . SPECIAL PRECAST SHEAR WALLS
(ASCE 7-05, TABLE 2.2.1)
7. RESPONSE COEFFICIENT . . . . . . . . . . . . . . . . . C
S
= 0.0431
8. RESPONSE MODIFICATION FACTOR . . . . . . R = 5.0
9. DESIGN BASE SHEAR . . . . . . . . . . . . . V = 11.5 kips.
10. ANALYSIS PROCEDURE USED . . . . . . . . . EQUIVALENT LATERAL FORCE ANALYSIS
3. CONCRETE:
A. ALL CONCRETE SHALL CONFORM TO THE SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS,
ACI 301, AND BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, ACI 318.
B. CONCRETE MIX DESIGNS:
1. 28-DAY COMPRESSIVE STRENGTH, PSI.
2. NORMAL WEIGHT STONE AGGREGATE (NW).
3. MINIMUM POUNDS PER CUBIC YARD WITHOUT WATER REDUCING ADMIXTURE. SUBTRACT 47.0 lbs/C.Y.
WITH WATER REDUCING ADMIXTURE. FLY ASH MAXIMUM 20% CEMENTITIOUS MATERIAL. USE TYPE II
CEMENT, WHERE CONCRETE IS EXPOSED TO EARTH.
4. MAXIMUM WATER/CEMENT RATIO PER ACI.
5. RANGE IN INCHES.
6. FR 1.5 POUNDS PER CUBIC YARD OF POLYPROPYLENE FIBERS IN SLABS ON GRADE.
WRA = WATER REDUCING ADMIXTURES.
7. TOTAL AIR CONTENT, PERCENTAGE RANGE.
C. ALL REINFORCING SHALL BE HIGH STRENGTH DEFORMED BARS, GRADE 60, ASTM A615, WITH
60,000 psi MINIMUM YIELD POINT EXCEPT FIELD-WELDED BARS SHALL BE GRADE 60, ASTM A706.
D. REINFORCEMENT PROTECTION:
1. CONCRETE POURED AGAINST EARTH . . . . . . . . . . . 3"
2. CONCRETE POURED IN FORMS BUT EXPOSED TO WEATHER OR EARTH:
a. IF BARS ARE LARGER THAN No. 5 . . . . . . . . . . 2"
b. IF BARS ARE No. 5 OR SMALLER . . . . . . . . . . . 11/2"
E. NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED OR AS AUTHORIZED BY
ANDERSON & HASTINGS. LAP SPLICES, WHERE PERMITTED, SHALL BE A MINIMUM OF 48 BAR DIAMETERS
UNLESS OTHERWISE NOTED. MAKE ALL BARS CONTINUOUS AROUND CORNERS.
F. DETAIL BARS IN ACCORDANCE WITH ACI DETAILING MANUAL AND ACI BUILDING CODE REQUIREMENT FOR
REINFORCED CONCRETE.
G. PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT REINFORCING AT POSITIONS SHOWN ON THE
PLANS.
H. ALL REINFORCING SHALL BE ACCURATELY PLACED AND ADEQUATELY SUPPORTED PRIOR TO CONCRETE
PLACEMENT (NO WETSTABBING) PER ACI 318 SECTION 7.5.
J. PLACE 2-No. 5 (1 EACH FACE) WITH 2'-0 PROJECTION AROUND ALL OPENINGS IN CONCRETE.
K. SLABS AND GRADE BEAMS SHALL NOT HAVE JOINTS IN A HORIZONTAL PLANE. ANY STOP IN CONCRETE
WORK MUST BE MADE AT CENTER OF SPAN WITH VERTICAL BULKHEADS AND HORIZONTAL KEYS UNLESS
OTHERWISE SHOWN. ALL CONSTRUCTION JOINTS SHALL BE AS DETAILED OR AS REVIEWED BY ANDERSON
& HASTINGS.
M. NO WELDING OF REINFORCING SHALL BE PERMITTED UNLESS SPECIFICALLY DETAILED OR REVIEWED BY
ANDERSON AND HASTINGS.
4. MASONRY:
A. CONCRETE MASONRY UNITS (CMU) SHALL COMPLY WITH ASTM-C90 TYPE 1 AND HAVE A MINIMUM
COMPRESSIVE STRENGTH OF 1,900 psi.
B. MORTAR SHALL BE TYPE S CONFORMING WITH IBC SECTION 2103.8 AND ASTM C-270, WITH A MINIMUM
COMPRESSIVE STRENGTH OF 1,800 psi.
C. GROUT SHALL COMPLY WITH IBC SECTION 2103.12, AND TMS 602/ACI 530.1/ASCE 6.
D. PRISM TESTING PER IBC SECTION 2105 MUST BE COMPLETED BY AN INDEPENDENT TESTING LABORATORY.
E. MASONRY (CONCRETE MASONRY UNITS, MORTAR, AND GROUT) SHALL DEVELOP 1,500 psi MINIMUM
COMPRESSIVE STRENGTH IN 28 DAYS, AS VERIFIED BY PRISM TESTING.
F. ALL REINFORCING AND ANCHOR BOLTS IN MASONRY WALLS SHALL BE FULLY GROUTED IN PLACE.
G. FILL ALL VOIDS AND BLOCK CELLS SOLIDLY WITH GROUT FOR A MINIMUM DISTANCE OF 24" BENEATH AND
12" EACH SIDE OF ALL BEAM AND LINTEL REACTIONS OR OTHER CONCENTRATED LOADS, UNLESS
OTHERWISE DETAILED.
H. BAR REINFORCING SHALL BE HIGH STRENGTH DEFORMED BARS, GRADE 60, ASTM A615, WITH 60,000 psi
MINIMUM YIELD POINT EXCEPT FIELD-WELDED BARS SHALL BE GRADE 60 ASTM A706.
J. HORIZONTAL JOINT REINF. SHALL BE PLACED IN ALL EXTERIOR AND BEARING WALLS SPACED AT 16" O.C.
K. PROVIDE VERTICAL CONTROL JOINTS WITHIN 10'-0 OF 90° CORNERS AND NOT TO EXCEED 30'-0, TYPICAL.
DO NOT EXTEND HORIZONTAL JOINT REINFORCING THRU CONTROL JOINTS. (NOTE: ALL BOND BEAM &
LINTEL REINFORCING BARS ARE TO BE CONTINUOUS THRU CONTROL JOINTS UNLESS NOTED OTHERWISE).
L. PROVIDE VERTICAL REINFORCING AS SHOWN AND DOUBLE (ONE EACH CELL) AT ALL OPENING JAMBS AND
ENDS OF WALLS, AND ONE EACH SIDE OF CONTROL JOINTS, AND AT CORNERS - EXCEPT AS OTHERWISE
SHOWN. GROUT CELLS SOLID AT VERTICAL REINFORCING.
M. LAP SPLICES & DOWEL PROJECTIONS: 3'-6 FOR #5, 2'-6 FOR #4.
5. FOUNDATIONS; SOIL BEARING PRESSURE USED IN DESIGN 3,000 psf, BASED ON REPORT No. 2125JT113
PREPARED BY WESTERN TECHNOLOGIES, DATED AUGUST 6, 2015.
6. NOTCHING OR CUTTING OF ANY STRUCTURAL MEMBER IS PROHIBITED UNLESS SPECIFICALLY DETAILED ON THE
STRUCTURAL DRAWINGS.
7. EXISTING CONDITIONS:
A. NOTIFY ANDERSON & HASTINGS IMMEDIATELY IF CONDITIONS ARE NOT COVERED BY THESE CONTRACT
DRAWINGS ARE EXPOSED DURING CONSTRUCTION.
B. ALL EXISTING CONDITIONS MUST BE INCLUDED IN SUBMITTED SHOP DRAWINGS AND NOTED AS SUCH.
CONTENT
CEMENT
(3)
-
611
FR 1.5
7600 East Orchard Road, Suite 250-S
Greenwood Village, CO 80111-2518
tel: 303.796.6000 Fax: 303.796.6099
www.mkkeng.com
Mechanical, Electrical & Energy Consultants
AN
DE
RS
ON
&
H
AS
TIN
GS
CO
NS
UL
TA
NT
S
Jo
b N
o. 0
60
-1
5-2
24
7
SPECIAL INSPECTION REQUIREMENTS
MATERIAL
CONCRETE
DURING THE TAKING OF TEST SPECIMENS.
INSPECT FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.
PERIODIC
PROTECTION OF MASONRY DURING COLD WEATHER OR HOT WEATHER.
DURING PREPARATION OF ANY REQUIRED PRISMS DURING CONSTRUCTION.
DURING THE TAKING OF GROUT SAMPLES FOR TESTING IF REQUIRED DURING CONSTRUCTION.
PRIOR TO GROUTING TO INSPECT THE GROUT SPACE.
DURING ALL GROUTING OPERATIONS.
MASONRY
CONTINUOUS OR PERIODIC
INSPECTION
INSPECTION TASKS
DURING THE PLACING OF REINFORCED CONCRETE, EXCEPT SITE WORK AND INTERIOR
SLAB-ON-GRADE, INCLUDING THE TAKING OF TEST CYLINDERS AND SLUMP TEST.
PRIOR TO THE CLOSING OF THE FORMS OR PRIOR TO THE DELIVERY OF CONCRETE TO THE
JOBSITE. ITEMS INSPECTED SHALL INCLUDE, BUT NOT BE LIMITED TO: REINFORCEMENT SIZES,
PLACEMENT LOCATION, LAP LENGTHS, CLEAR DISTANCES, REINFORCING STEEL AROUND
OPENINGS, DOWELS INTO MASONRY WALLS (TYPICAL PLUS ADDITIONAL OPENINGS).
AT THE START OF LAYING MASONRY UNITS: ITEMS INSPECTED SHALL INCLUDE, BUT NOT BE
LIMITED TO:
1. MASONRY UNITS, REINFORCEMENT, CEMENT, LIME, AGGREGATE, AND ALL OTHER
MATERIALS MEET THE REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS.
2. MORTAR MIXING USING SPECIFIED MATERIALS AND PROPORTIONS OF INGREDIENTS.
3. METHODS OF MEASURING MATERIALS FOR MORTAR.
4. USE OF OPEN END UNITS AT STACK BOND CONDITIONS AT CORNERS OR ABUTTING
TO CONCRETE.
AFTER THE PLACEMENT OF REINFORCING STEEL PRIOR TO GROUTING. ITEMS INSPECTED SHALL
INCLUDE, BUT NOT BE LIMITED TO: REINFORCEMENT SIZES, PLACEMENT, LAP LENGTHS, CLEAR
DISTANCES, REINFORCING STEEL AROUND OPENINGS.
PRIOR TO GROUTING TO INSPECT EMBEDDED PLATES, BOLTS, BASE PLATES, AND OTHER
ANCHORAGES.
PERIODIC
(PER IBC TABLE 1704.4)
REINFORCING STEEL
(INCLUDING BOLTS EMBEDDED
IN CONCRETE)
PRIOR TO START OF WORK:
1. DURING THE TAKING OF GROUT SAMPLES FOR TESTING.
2. DURING THE PREPARATION OF MASONRY PRISMS.
NOTES:
1. REFER TO SPECIFICATIONS FOR ADDITIONAL INSPECTION REQUIREMENTS.
2. OWNER WILL EMPLOY SPECIAL INSPECTOR.
PERIODIC
(PER IBC TABLE 1704.5.1)
PHOTO 1
(MATCH PATTERN & FINISH ON NEW SCREEN WALL 4' WIDE SOLID GATE ON
EAST SIDE SELECTED BY CONTRACTOR).