omnik micro-inverter-m248-m500-kit
TRANSCRIPT
15 year15 Warranty
Features
Omniksol-M248Type Omniksol-M500
Micro inverterOmniksol-M248/Omniksol-M500
2014
/06
Eng
lish
V1
High efficiency (Max. 94.5%)Reduce shading issues, improve the generating capacity of the whole solar PV systemAC/DC high frequency isolation technologyMaximum connection of 15 Micro-invertersAdopted electric power carrier communicationEasy design, Plug-and-play chain installationRemote monitor to each module integrated ENS function, complied with safety standard, can be connected to grid directly
M248M500
Input (DC) Recommended Maximum Input PowerMax DC Voltage Operating MPPT Voltage Range MPPT Voltage Range at Nominal PowerStart up DC VoltageTurn off DC VoltageMaximum DC Short Circuit CurrentMaximum Input CurrentOutput (AC)Max. AC Power Max. AC Current Nominal Grid VoltageNominal Grid FrequencyGrid Voltage Range*Grid Frequency Range*Power FactorTotal Harmonic Distortion (THD)Night time Power ConsumptionMaximum Units Per BranchEfficiencyMax. EfficiencyCEC Weighted EfficiencyMPPT EfficiencyPhysical StructureDimensions(W*H*D)Weight Environmental Protection RatingCooling ConceptOvervoltage CategoryReference StandardSafety StandardEMC StandardGrid StandardGeneral DataOperating Ambinent Temperature RangeOperating Internal Temperature RangeRelative HumidityMax. Altitude (above sea level)Isolation TypeCommunicationWarranty
300W54V
18-50V26-45V
26V18V
10.0A15A
248W1.11A
220V/230V/240V50Hz/60Hz180-265V
47-51.5Hz/57-60.5Hz>0.99<3%
<100mW15
95.5%94.5%99.9%
234x163x26mm1.6kg
2x300W54V
18-50V26-45V
26V18V
10.0Ax215A
500W2.3A
220V/230V/240V50Hz/60Hz180-265V
47-51.5Hz/57-60.5Hz>0.99<3%
<100mW8
96.5%95.5%96.9%
420 x 130 x 27 mm2.4kg
IP 65 (According to IEC 60529)Natural convection
PV II / Mains III (According to IEC 62109-1)
EN 62109, AS/NZS 3100EN 61000-6-1, EN 61000-6-3, EN 61000-6-2, EN 61000-6-4, EN61000-3-2, EN61000-3-3
VDE-AR-N-4105, VDE 0126-1-1, G83/1, UTE C15-712-1, AS4777, NB/T 32004-2013, CEI 0-21
-40 °C to +65 °C -40 °C to +85 °C
0% to 98%, no condensation2000m
HF transformer isolationPLCC (Power Line Carrier Communication)
15 Years (4-25 years option)
*The AC voltage and frequency range may vary depending on specific country grid Products updating continues. Any data change will not be informed exclusively. Omnik company reserves the right of final interpretation of product technical data and copyrights.
M248M500
5year
555 Warranty
Micro Kit
Wiring Diagram
Features
“Micro kit” acts as the power interface (PI) to the utility grid and communications interface with the internet. It is a device installed at the coupling point to the utility grid to provide safety functions such as over/under voltage, over/under frequency, leakage current detection and DC injection detection. The real-time performance informa-tion of energy harvest for all OMNIK micro-inverter systems can be collected by Microkit and transmitted to OMNIK Solar Energy Data Acquisition System for global real-time monitoring.
Over/under voltage protectionOver/under frequency protection Leakage current detection DC injection detection Disconnection of grid by four relays.Web-based online monitoring per-moduleExpandable for large systems
Address: XingHu Rd. Nr. 218 bioBAY Park A4-414, 215123, SuZhou, China Tel: +86-512-6956-8216 Fax: +86-512-6295-6682 E-mail: [email protected] Website: http://www.omnik-solar.com
Omniksol-Microkit Technical DataMicrokit 4kModel
Data(AC)Rated PowerOperating voltage rangeNominal operating voltageNominal operating frequencyMechanical DataEnclosure environmental ratingOperating temperatureDimensions (WxHxD) WeightFeaturesComplianceWarrantyPower Consumption
3.68kW230V
Matching Grid Demand16A
IP40-20°C~65°C
207x186x81mm1kg
CQC/VDE0126-1-1/VDE-AR-N-4105/AS47775 Years
6W