operating instructions tr611top2 tr622top2 en

14
Assembly and operating instructions 1 Time switch Instrucciones de montaje y de uso 15 Interruptor horario Manual de instruções e de montagem 29 Temporizador Montage- und Bedienungsanleitung 43 Schaltuhr TERMINA TR 611 top2 TR 622 top2 611 0 102 622 0 102 309 259 04 TERMINA TR 611 top2 TERMINA TR 622 top2 MENU OK 1 0 6 12 18 24 2 p o t 1 1 6 R T 2,5mm 2 0,5mm - 2 m m 8 230-240V~ 50-60Hz R 10a - 30T 16(10)A 250V~ 1 C1 2 3 Ext MENU OK 1 2 0 6 12 18 24 2 p o t 2 2 6 R T 2,5mm 2 0,5mm - 2 230-240V~ 50-60Hz R 10a - 30T C1/C2 16(10)A 250V~ C1 C2 Ext 2 m m 8 Ext 1 4 5 6 1 3 4 5 6 GB Current connection required for smooth zerocrossing switch operation (see connection diagram)!

Upload: mohdsaadahmad

Post on 16-Apr-2017

225 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: Operating Instructions TR611top2 TR622top2 En

� Assembly and operating instructions 1Time switch

� Instrucciones de montaje y de uso 15Interruptor horario

� Manual de instruções e de montagem 29Temporizador

� Montage- und Bedienungsanleitung 43Schaltuhr

TERMINA TR 611 top2 TR 622 top2611 0 102622 0 102

309 259 04

TERMINA TR 611 top2 TERMINA TR 622 top2

MENU OK

1

0 6 12 18 24

2pot

116

RT

2,5mm2

0,5mm -2

mm8

230-240V~50-60Hz

R 10a - 30T

16(10)A 250V~

1

C1

2 3

Ext

MENU OK

1 2

0 6 12 18 24

2pot

226

RT

2,5mm2

0,5mm -2

230-240V~50-60Hz

R 10a - 30TC1/C216(10)A 250V~

C1

C2

Ext 2

mm8

Ext 1

4 5 6

1 3

4 5 6

GB

Current connection required for smooth zerocrossing switch operation(see connection diagram)!

TERMINA 611_622 top2_309 259 04_GB.qxd 31.10.2008 10:58 Uhr Seite 1

Page 2: Operating Instructions TR611top2 TR622top2 En

ContentsBasic advice 3Screen display and keys/Operating principle 4Menu overview 5Connection/assembly 6Initial start-up 7RESET 10Menu item PROGRAM

Reprogram switching time 8Change/delete switching time (applies also for pulse and cycle) 9Pulse programming 10Cycle programming 11

Menu item MANUALManual and permanent switching 12

Menu item OPTIONSPIN code 12External input 13

Memory card OBELISK top2 13Technical data 14Service address/Hotline 142

TERMINA 611_622 top2_309 259 04_GB.qxd 31.10.2008 10:58 Uhr Seite 2

Page 3: Operating Instructions TR611top2 TR622top2 En

GBBasic advice

• The device is designed for installation on DIN top hat rails (in accordance with EN 60715)

• Corresponds to type 1 BSTU in accordance with IEC/EN 60730-2-7

• Power reserve (10 years) is reduced with memory card inserted (in battery mode)

• Designated use:The timer is used for lighting, air-conditioning, flushing etc. .

• For use only in closed, dry rooms

Do not use on safety devices, e.g. escape route doors, fire safety equipment etc.

• DisposalDispose of equipment in an environmentally-friendly manner

Danger of death through electric shock or fire!� Installation should only be carried out by professional electrician!

WARNING

3

TERMINA 611_622 top2_309 259 04_GB.qxd 31.10.2008 10:58 Uhr Seite 3

Page 4: Operating Instructions TR611top2 TR622top2 En

4

Screen display and keys Operating principle

0 6 12 18 24

Time display

Date display

Channel status C1 + C2:ON OFF

� MENU– Activate display– Open menu– Terminate programme– ESC

(Leave menu)

YESConfirmation

OK press

NOChange/revise

� �press

� O K– Confirm

selection– Confirm

selection� � �

Alternatives are displayed

Days of the week from1 – 7

Display of active buttons with relevant function

Programmed switch times

bbbb

1. Read text lineFlashing text/symbol represents question

bbbb

2. Make decision

TERMINA 611_622 top2_309 259 04_GB.qxd 31.10.2008 10:58 Uhr Seite 4

Page 5: Operating Instructions TR611top2 TR622top2 En

Menu overview

19 10 06C1 OFF C2 OFF

9:4046

PROGRAM

NEW

CHECK

Modify

DELETE

END

MENU

TIME/DATE MANUAL OPTIONS END

TIME CHANNEL C1

SET DATE

SU-WI

WEEK DAY

FORM DATE

FORM TIME

END

PERM ON

PERM OFF

OVERRIDEON

TIMER

OPERATINGHOUR

EXTERNAL INPUT

� � � � �

HOLIDAY

RANDOM

END

LCD ILLUMINA-TION

LANGUAGE

PIN

FACTORY SETTINGS

INFO

END

GB

5

TERMINA 611_622 top2_309 259 04_GB.qxd 31.10.2008 10:58 Uhr Seite 5

Page 6: Operating Instructions TR611top2 TR622top2 En

6

Connection/installation

Connect cable

� Strip cable by 8 mm (max. 9).� Insert cable at 45° in the open terminal

(2 cables per terminal is possible).� Only for flexible wiring: Press screwdriver downwards

to open spring screwless terminal.

Warning, danger of death through electric shock!�Must be installed by professional electrician!� Disconnect power source.� Cover or shield any adjacent live compo-

nents.� Ensure device cannot be switched on!� Check power supply is disconnected!� Earth and bypass!

WARNING

45° cable

Spring screw-less terminalNC contact

Test tap

Spring screwlessterminal

TERMINA 611_622 top2_309 259 04_GB.qxd 31.10.2008 10:58 Uhr Seite 6

Page 7: Operating Instructions TR611top2 TR622top2 En

Initial start-up(see fig.)

Set date, time and summer/winter time rule

� Press desired button and follow on-screen

instructions.

GERMAN

YEAR

MONTH

DAY

HOUR

MINUTE

SU-WI EUROPA

SU-WI GB/IRL/P

SU-WI FIN/GR/ TR

SU-WI CDN

SU-WI USA07

SU-W IRAN

SU-WI FREERULE

SU-WI FIX DATE

NO SU-WI

� �okor

19 10 06C1 OFF C2 OFF

9:4046

GB

7

TERMINA 611_622 top2_309 259 04_GB.qxd 31.10.2008 10:58 Uhr Seite 7

Page 8: Operating Instructions TR611top2 TR622top2 En

8

Reprogram switching time(see fig.)

� Press MENU.

� Confirm with OK or select desired setting � �.

� Reconfirm with OK .

You have 84 memory locations available.

NEW

SWITCH

�ok

PROGRAM

CHANNEL C1

same switching time for several days = Block

Switchingtime for one day

FREE 84

ON C1 On

HOUR

MINUTE

MONDAY

SAVECOPY

ADD TUESDAY

SAVE

��

TERMINA 611_622 top2_309 259 04_GB.qxd 31.10.2008 10:58 Uhr Seite 8

Page 9: Operating Instructions TR611top2 TR622top2 En

9

Change/delete switching time(applies also for pulse andcycle)(see fig.)

� Press MENU.

� Confirm with OK or select desired setting � �.

� Reconfirm with OK .

You can either change or delete a block, i.e. a

switching time copied for several days

(e.g. Mon-Fri) or a single switching time.

SWITCH�ok

PROGRAM

NEW

CHECK

MODIFY

DELETECHANNEL C1

MONDAY

MODIFYHOUR

MODIFYMINUTE

MODIFYSINGLE DAY

MODIFY BLOCK

��

GB

TERMINA 611_622 top2_309 259 04_GB.qxd 31.10.2008 10:58 Uhr Seite 9

Page 10: Operating Instructions TR611top2 TR622top2 En

10

Pulse programming(see fig.)

(for pause signals, air-conditioning,

flushing etc.)

� Press MENU.

� Confirm with OK or select desired

setting � �.

RESET

� Press the 4 buttons simultaneously.

You can choose between KEEP PROGRAM

and DELETE PROGRAM .

CHANNEL C1

MEM FREE 84

SWITCH

PULSE

CYCLE

�ok

okPROGRAM

NEW

ON C1 On

HOUR

MINUTE

SECONDS

PULSE LENGTH-TION

MINUTE

SECONDS

MONDAY

SAVECOPY

ADD TUESDAY

SAVE

��

TERMINA 611_622 top2_309 259 04_GB.qxd 31.10.2008 10:58 Uhr Seite 10

Page 11: Operating Instructions TR611top2 TR622top2 En

Cycle programming(see fig.)

(with cyclical time functions,

e. g. water treatment etc.)

� Press MENU.

� Confirm with OK or select the

desired setting with � �.

11

CHANNEL C1

MEM FREE 84

START CYCLE

HOUR

MINUTE

MONDAY

PULSE LENGTH-TION

PAUSE

ENDLESSWITH END

STOP CYCLE

��SWITCH

PULSE

CYCLE

�ok

okPROGRAM

NEW

GB

TERMINA 611_622 top2_309 259 04_GB.qxd 31.10.2008 10:58 Uhr Seite 11

Page 12: Operating Instructions TR611top2 TR622top2 En

Manual and permanentswitchingManual and permanent switching can be

selected by using menu option MANUAL or

(in the automatic display) via a combination of

buttons (see fig.) .

Activate manual switching

� Quickly press both buttons simultaneously.

Activate permanent switching

� Press both buttons simultaneously for 2 sec.

Cancelling manual/permanent switching

� Press both buttons simultaneously.

ok

ChannelC1

ChannelC2

PIN code

The PIN code is set in the menu under

OPTIONS (see fig.). If you have forgotten the

PIN call the Theben Hotline.

OPTIONS

OPERATINGHOUR

EXTERNAL INPUT

WITH PIN

CURRENT PIN

NEW PIN

00 00

LCD ILLUMINA-TION

LANGUAGE

PIN

FACTORY SETTINGS

INFO

ok

12

TERMINA 611_622 top2_309 259 04_GB.qxd 31.10.2008 10:58 Uhr Seite 12

Page 13: Operating Instructions TR611top2 TR622top2 En

13

External input

The EXTERNAL INPUT can be set using

OPTIONS menu entry (see fig.).

� Use switch without glow lamp path.

CHANNEL C1

BUTTON MANUAL

TIMERSWITCH

INACTIVE

ok

�ok

OPTIONS

OPERATINGHOUR

EXTERNALINPUT

LCD ILLUMINA-TION

LANGUAGE

PIN

FACTORY SETTINGS

INFO

GBMemory card OBELISK top2

Use memory card

� Insert memory card in the timer.

� Request savedswitch timings, read to/from

the timer or start Obelisk program.

� Memory card OBELISK top2

(No. 907 0 404) after Pro-

gramming etc. remove

and store in cover.

Avoid mechanical overloador contamination caused by other storage/ transport.

TERMINA 611_622 top2_309 259 04_GB.qxd 31.10.2008 10:58 Uhr Seite 13

Page 14: Operating Instructions TR611top2 TR622top2 En

Technical data• Nominal voltage: 230–240 V~, +10 %/-15 %• Frequency: 50-60 Hz• Power consumption: max. 6 VA• Switching output: phase-independent

(zero-crossover switching),• TR 611 top2: suitable for switching SELV

(Safe Extra-Low Voltage) • Contact: two way switch• Contact material: AgSnO2• Switching capacity max.: 16 A, 250 V~, cos ϕ = 1;

10 A, 250 V~, cos ϕ = 0.6• Switching capacity min.: 10 mA/230 V AC

100 mA/24 V AC/DC• Incandescent lamp load: 2600 W • Halogen lamp load: 2600 W• Fluorescent lamp load: uncorrected:

1000 VA series corrected730 VA (80 μF) parallel corrected

• Compact fluorescent lamps: 22 x 7 W, 18 x 11 W 16 x 16 W, 20 x 14 W, 23 x 15 W,

• Permissible ambient temperature: –30 °C ... +55 °C

• Protection class: II in accordance with EN 60730-1 for designated installation

• Protection rating: IP 20 in accordance with EN 60529

• Pollution level: 2• Power consumption: 10 years at 20 °C

Service address/HotlineService address

Theben AGHohenbergstr. 3272401 HaigerlochGERMANYPhone +49 (0) 74 74/6 92-0 Fax: +49 (0) 74 74/6 92-150

Hotline

Phone+49 (0) 74 74/6 92-369Fax: +49 (0) 74 74/6 [email protected], telephone numbers etc.www.theben.de

14

TERMINA 611_622 top2_309 259 04_GB.qxd 31.10.2008 10:58 Uhr Seite 14