ophir-spiricon inc. 1 january 2009 ophir-spiricon inc. the true measure of laser performance™...
TRANSCRIPT
OPHIR-SPIRICON INC.
1 January 2009
OPHIR-SPIRICON INC.The True Measure of Laser Performance™
What’s New for 2009
OPHIR-SPIRICON INC.
2 January 2009
How do I Measure MY Laser?
■ Power / Energy (Continuous or Pulsed)■ Temporal Profile (for pulsed lasers)■ Beam Profile■ Beam Variations Over Time
□ Beam Wander
□ Size and Shape
□ Power and Energy
OPHIR-SPIRICON INC.
3 January 2009
What Can We Provide You?
■ Ophir-Spiricon Offers Instruments for Measuring □ Power- from Picowatts to Kilowatts□ Energy- from Pico Joules to Hundreds of Joules□ Temporal Profile- from sub µs to ms□ Wavelength- from 157 nm to 20um□ Laser Beam Profiling
▪ Any laser▪ Any Wavelength ( from soft X-ray to THz)▪ Any power (from sub nW to over 150 kW)▪ Any size beam (from micron to meters)
OPHIR-SPIRICON INC.
4 January 2009
What’s NEW in Power/Energy for 2009?
■ PULSAR- Multi Channel High Speed USB II Interface□ Up to 25,000 Hz on ALL
Channels Simultaneously
□ Now supports ALL SmartHeads
■ Ideal for Multi-Head Applications
OPHIR-SPIRICON INC.
5 January 2009
What’s NEW in Power/Energy for 2009?
■ Vega- NEW COLOR Hand-Held Display□ Bright 320X240 Color TFT
Display▪ Optimize your display for
various laser glasses
□ ILLUMINATED KEYS▪ Easy to use in dim light
□ New Ergonomic Design
OPHIR-SPIRICON INC.
6 January 2009
What’s NEW in Power/Energy for 2009?
■ 100 mm Diameter Pyroelectric Head□ 96 mm Clear Aperture
for extra large beams□ Supplied with
removable diffuser for higher powers and energies
□ Comes with broadband coating
OPHIR-SPIRICON INC.
7 January 2009
What’s NEW in Power/Energy for 2009?
■ PE50 Pyroelectric with new diffuser
■ Rep rates to 3000Hz■ TEN TIMES the
previous damage limit.□ 40J/cm for 1ms pulses
□ 1J/cm for <100ns pulses
OPHIR-SPIRICON INC.
8 January 2009
What’s NEW in Power/Energy for 2009?
■ New High Damage Threshold Coating for Long Pulse Lasers.
■ FIVE TIMES the previous limit.□ 50 J/cm2 for 2ms pulses
□ 250 J/cm2 for 10ms pulses
OPHIR-SPIRICON INC.
9 January 2009
What’s NEW in Power/Energy for 2009?
■ Energy Head specially made for IPL applications□ Can be used with
and without gels
□ Easy clean design
OPHIR-SPIRICON INC.
10 January 2009
What’s NEW in Power/Energy for 2009?
■ 250W Long Pulse Power Head □ Large (33 mm)
Aperture
□ Up to 600J Total Energy
■ High Energy Density□ >400 J/cm2 for >2ms
pulses
OPHIR-SPIRICON INC.
11 January 2009
What’s NEW in Power/Energy for 2009?
■ 300W Low-Profile Long-Pulse Head□ ONLY 20 mm Thick
■ High Power Density Coating□ Up to 150 J/cm2 for
20 ms pulses
OPHIR-SPIRICON INC.
12 January 2009
What’s NEW in Power/Energy for 2009?
■ 500W FAN-COOLED Head for Long Pulse Lasers□ 65 mm aperture for
larger beams
□ 600J Total Energy
■ High Energy Density□ 200 J/cm2 for 10 ms
pulses
OPHIR-SPIRICON INC.
13 January 2009
What’s NEW in Power/Energy for 2009?
■ 100/500W Convection-Cooled Head□ 75W continuous, up to
500W intermittent.□ 65 mm aperture for large
beams□ Can be used with IPL
Sources up to 600 J!□ 30 J/cm2 for 10ms pulses
OPHIR-SPIRICON INC.
14 January 2009
What’s NEW in Power/Energy for 2009?
■ 1,500 Watt Long-Pulse RP Head□ Measures CW Power
& PULSE ENERGY
□ Also Measures Temporal Pulse shape!
■ Patented “RP” Technology
OPHIR-SPIRICON INC.
15 January 2009
BEAM PROFILING
■ The QUANTITATIVE way To Characterize Your Laser□ NO Guesswork!
□ All characteristics of your beam
□ ISO Beam Widths-No arguments
□ Easy to use
□ No operator error!
OPHIR-SPIRICON INC.
16 January 2009
Laser Profiling Equipment for Lab Use
■ Compact
■ USB-II AND FireWire!
■ From 190-1100 nm and 1450-1625 nm
■ Can even measure focused spots!
■ Any Wavelength-all you do is change detector arrays
OPHIR-SPIRICON INC.
17 January 2009
Laser Profiling Equipment for Lab Use
■ PYROCAM III
■ IR to THz Wavelengths
■ Patented Pyroelectric uncooled detector
■ Stable, robust, easy to use
■ FireWire interface
OPHIR-SPIRICON INC.
18 January 2009
Laser Profiling Equipment for Lab Use
■ Accessories□ Wide range for almost
every application▪ Range extenders for UV ▪ Beam Expanders and
reducers▪ Attenuation kits
OPHIR-SPIRICON INC.
19 January 2009
What’s NEW in Profiling for 2009?
■ BEAMGAGE□ A whole NEW
way of looking at your beam
■ Totally New Software□ Supported by
Microsoft VISTA
OPHIR-SPIRICON INC.
20 January 2009
NEW BeamGage Profiling Software for 2009
■ New Functionality
■ Ability to Test your Beam Calculations with Theoretical Beams!
■ Better 3D!
OPHIR-SPIRICON INC.
21 January 2009
What’s NEW in Profiling for 2009?
■ New Beam Creator lets you see how a Theoretical Beam should appear.
■ Can be used to ‘calibrate’ beam widths
■ Will Revolutionize the Science of Spatial Beam Profiling!
OPHIR-SPIRICON INC.
22 January 2009
What’s NEW in Profiling for 2009?
■ LBS-300 Integrated Focused Spot SYSTEM□ Measures focused spots as
small as 60 um
□ UP to 400 W total power
□ Works with short focal length lenses!
■ Image your FOCUSED SPOT!
OPHIR-SPIRICON INC.
23 January 2009
What’s NEW in Profiling for 2009?
■ LARGE Format Profiling Camera□ 24 mm X 36 mm Array
□ 11.2 Mpixels
□ FireWire Interface
□ 190 nm to 1100 nm range
■ Directly Image Large Beams!
OPHIR-SPIRICON INC.
24 January 2009
What’s NEW in Profiling for 2009?
■ BeamCube Integrated Beam Characterization SYSTEM□ Measures spatial profile,
focal spots, temporal pulse shape and power all in one unit!
□ UP to 150 W total power
■ Know your Beam Totally!
OPHIR-SPIRICON INC.
25 January 2009
What’s NEW in Profiling for 2009?
■ M2-200s■ FAST new Smaller M2
system■ Industrial design-even
for continuous use■ M2 in as little as 45
seconds!■ TRUE ISO 11146!
OPHIR-SPIRICON INC.
26 January 2009
What’s NEW in Profiling for 2009?
■ SP 503/620 USB-II MiniCameras
■ Built-in Pulse Sync operation
■ Small footprint■ High density Pixels■ Lower cost
OPHIR-SPIRICON INC.
27 January 2009
Industrial Beam Profiling Equipment
■ For 400-1100 nm Lasers
■ Power up to 4 kW
■ Integrated systems□ Some measure power and
temporal profile as well as Beam Profile
OPHIR-SPIRICON INC.
28 January 2009
Industrial Beam Profiling Equipment
■ Now for high power CO2 as well as Near IR applications□ Up to 48 mm diameter
beams□ Up to 8 kW continuous
power□ Can be permanently
installed for on-line beam monitoring
▪ Totally transparent to the process
OPHIR-SPIRICON INC.
29 January 2009
SUMMARY
■ New Technology Makes Diagnostics Easier■ Results in:
□ More Reliable Operation
□ Better Beam Quality
□ Less Waste
□ Higher Profits
OPHIR-SPIRICON INC.
30 January 2009
For More Information…
■ Contact your local representative■ Find us on the web:
□ www.ophir-spiricon.com
THANK YOU FOR WATCHING