OPN_DL UTILITY SOFTWARE

INSTALLATION AND USER GUIDE - v2.03

Electronic Reading Systems Ltd 14 Wolseley Business Park

Kempston Beds

MK42 7PW

Tel: 01234 855300 Fax: 01234 855446

www.ers-online.co.uk

Page 2: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

CONTENTS

1.0 INTRODUCTION 2.0 INSTALLING OPN_DL & DRIVERS 2.1 Installing the OPN_DL Application 2.2 Installing the OPN2001 Drivers

3.0 USING OPN_DL

3.1 Running OPN_DL 3.2 Downloading Stored Data from the OPN2001 3.3 Format of the Output Data File 3.4 Backup Data Files 4.0 CONFIGURING THE OPN2001

4.1 The Configurable Parameters 4.2 Saving the displayed configuration to Disk 4.3 Retrieving a Configuration from disk 4.4 Cloning Devices 5.0 SHUTTING DOWN OPN_DL

Page 3: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

1.0 INTRODUCTION

OPN_DL is a simple to use utility program for use with the OPN2001.

The software allows stored data to be collected from the terminals and provides facilities to allow configuration of the OPN2001s.

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

Page 4: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

2.0 INSTALLING OPN_DL AND DRIVERS

2.1 INSTALLING OPN_DL APPLICATION

NOTE: Previous versions of the OPN_DL application installer automatically installed both the OPN_DL application and the OPN2001 hardware drivers. This led to differences in the installation procedure for Windows XP (totally automatic), and Vista/ Windows7. For this reason, the OPN_DL installer no longer attempts to install the hardware drivers automatically. As a result the application and drivers are now installed as 2 separate procedures summarised in sections 2.1 and 2.2 below.

To install the OPN_DL utility execute the Microsoft Installer OPN_DL.msi and proceed as show below:

NOTE: The .NET 2.0 Framework is a prerequisite of the OPN_DL application.

The .NET 2.0 Framework may be downloaded from the ERS website or direct from Microsoft. (Approximately 22MB download)

1) Click Run

2) Click Next

3) Click Next

4) Click Next

5) Click Close. OPN_DL is now installed.

Note: The software must be installed from a logon with full Administrative rights

NOTE: These screenshots are based on XP. Other operating systems may differ in style and detail. For example additional security warnings will nor-mally be presented under Vista and Windows7 )

Note: Do not connect the OPN2001 data collector onto your PC until after the drivers have been manually installed - see section 2.2 below

Page 5: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

2.2 INSTALLING OPN2001 DRIVERS To install the OPN2001 drivers run the OPN2001 Driver Installer USB Drivers Installer.exe and proceed as follows:

1) Click Run

2) Click Next

3) Click Next

4) Click Next

5) Click Next. The OPN drivers are now installed

Note: Do not connect the OPN2001 data collector onto your PC until after the drivers have been manually installed below

Page 6: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

OPN Hardware Drivers:

Note 1: The drivers automatically allocate a ‘virtual’ COM port for the OPN2001 allowing it to operate just as if it were plugged into one of the PC COM ports.

The OPN_DL utility will automatically detect the COM port allocated to the OPN2001, avoiding the requirement for manual configuring of the software. Note 2: If the OPN2001 is subsequently connected to a different USB port on the PC it will be seen as a new device. The Found New Hardware wizard will then automatically run to allow the OPN2001 to be installed to this USB Port. In this case a new virtual COM port will be assigned for the device when used via this USB port. Note 3: OPN_DL expects that only 1 OPN2001 will be connected to the PC. In the event that multi-ple devices are simultaneously connected, OPN_DL will communicate only with the 1st OPN2001 found when searching for devices. If that device is disconnected OPN_DL will re-enter ’search’ mode finding the ‘next’ connected device.

Page 7: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

3.0 USING OPN_DL OPN_DL software provides the following facilities: • Downloading stored data from the OPN2001 • Configuring the OPN2001 3.1 Running OPN_DL The installation procedure above will create an icon for OPN_DL on the PC desktop. OPN_DL can be run from the desktop icon or from the Start menu.

1) OPN_DL splash screen

2) Click OK to set default operating mode for OPN_DL

(This message will be displayed only when running OPN_DL for the 1st time).

3) OPN_DL will automatically search for a connected device and will display an appropriate message.

The example screenshots shown here illustrate the connec-tion of an OPN2001 which currently contains no stored data.

4) The Change Parameters facility will only be displayed when a device is connected.

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

Page 8: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

3.2 Downloading Stored Data from the OPN2001 To download stored data from the OPN2001 proceed as follows:

1) Execute OPN_DL 2) Select the required download option by clicking as required to enable or disable. The option will be highlighted when enabled.

The selected settings will be stored and will remain as default settings until subsequently changed by the operator if required.

Store DTS allows the date/ time stamp for each stored barcode to be included in the output data file.

Clear After Download allows OPN_DL to automatically clear the OPN2001 memory after a successful download.

3) Connect the OPN2001 to a suitable USB port on the PC.

OPN_DL will automatically connect to the device and attempt to download stored data.

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

Page 9: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

4) Specify the required location, name and file type (.txt or .xls) for the output data file and click Save.

(The default path for the output file is the My Documents folder in the current user profile).

The specified path and filename will be remembered and will be used as default for subsequent downloads until changed by the operator.

5) OPN_DL will overwrite the data file if it already exists.

Click Yes to confirm overwrite, NO to return to the Save as screen above for selection of a new output file.

6) OPN_DL confirms that the data records have been written to the output data file.

7) To download another OPN2001 simply unplug the device and plug-in another.

Note: OPN_DL will automatically synchronise the real-time clock in the OPN2001 to the PC clock every time the device is connected.

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

Page 10: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

3.3 Format of the Output Data File The data collected from the scanner may be written to a simple ASCII text file or to an .xls spreadsheet.

If written as a text file the data records will be written in the following format::

Barcode, ScanDate 5025874103041,20/06/2008 08:31:11 88834561,20/06/2008 08:31:13 50259635874,20/06/2008 08:31:13 74-1-GX,20/06/2008 08:31:14

If written as an .xls document the data will be presented in Excel as:

Note that the date/time stamp will only be present in the output data file if the Store DTS option from the OPN_DL main screen is set to ON when the device is downloaded:

Page 11: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

3.4 Backup Data Files In addition to the output data file produced above OPN_DL also writes a file to a history folder located in the Application Data folder for All Users.

For example for XP the back up data files will be stored at:

C:\Documents and Settings\All Users\Application Data\Electronic Reading Systems Ltd\OPN_DL\HISTORY These history files are written in the text file format as shown in section 3.3 above, and are named with the date/time of creation as OPN_ddmmyyyyhhmmss.txt

Where ddmmyyyy is the date (day, month and year) and hhmmss is the time (hours, minutes and seconds) For example: OPN_20062008083134.txt

Page 12: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

4.0 CONFIGURING THE DATA COLLECTOR

To configure the data collector connect the OPN2001 and proceed as follows:

1) Click Change Parameters

Note: If the Change Parameters button is not displayed, unplug and re-plug the data collector

2) Select Symbology Parameters or Device Parameters as required

3) The configuration of the connected OPN2001 is automatically extracted and displayed.

Use the relevant drop down lists to change settings as required.

Note: Selecting a setting via the drop down lists will immediately load that setting down to the device and verify.

4) To set an OPN2001 into the factory default state click Set Defaults.

5) To clone OPN2001s see section 4.4 below.

6) Click to exit Configuration Mode.

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

Page 13: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

4.1 Configurable Parameters The configurable parameters for the OPN2001 are displayed under two tabs grouping together those parameters related to the barcode symbology and those associated with the operation of the OPN2001 itself:

Further details of the configurable parameters follow:

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

Note: Setting the bleeper volume. To set the bleeper volume ensure that Volume and Override OPN volume are both set to ON. Now select the required volume setting from the drop down menu under Default Override Set-ting. Selecting a new volume setting from the menu will immediately download that setting to the OPN2001 (Note: the LOW+1 volume setting is currently the lowest available setting in the OPN2001. Setting the volume to LOW has no affect).

Page 14: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

SYMBOLOGY PARAMETERS

PARAMETER COMMENTS DEFAULT

CODE 39

Standard Enable/ Disable (ON/ OFF) ON

Full ASCII Enable/ Disable (ON/ OFF) OFF

Check Digit Verify check digit (ON/ OFF) OFF

Send Check Digit Transmit Check digit (ON/ OFF) OFF

EAN/ UPC

EAN +UPC Enable/Disable (ON/OFF) ON

Convert UPCE to A ON/ OFF OFF

Convert EAN8 to EAN13 Type

Add zeroes + change code type to EAN13 (ON/ OFF)

OFF

Convert EAN8 to EAN13

Add zeroes. Do not change code type (ON/ OFF)

OFF

UPC A Preamble NONE/ SYSTEM CHR/ SYSTEM + COUN-TRYCODE

SYSTEM CHR

Security Level 0

Addon NO ADDON/ ADDON ONLY/ BOTH NO ADDON

Addon Redundancy # times to decode UPC/ EAN barcode without addon (2—20)

2

Send UPC A Check Digit

ON/ OFF ON

Send UPC E Check digit

ON/ OFF ON

UPC E Preamble NONE/ SYSTEM CHR/ SYSTEM + COUNTRY CODE

SYSTEM CHR

2 of 5

Interleaved 2 of 5 Enable/ Disable (ON/ OFF) ON

Interleaved 2 of 5 check digit

Verify Check Digit (ON/ OFF) OFF

Convert Interleaved 2 of 5 to EAN13

ON/ OFF OFF

Send Interleaved 2 of 5 Check Digit

Transmit Check digit (ON/ OFF) OFF

Interleaved 2 of 5 Length1/ Length 2

1 Discrete Length (L1= length, L2 = 0) 2 Discrete Lengths (L1 > L2) Length within Range (L1 <L2) Any length (L1 = L2 = 0)

L1 = 14 L2 = 0

Industrial 2 of 5 Enable/ Disable (ON/ OFF) OFF

Industrial 2 of 5 Length1/ Length 2

1 Discrete Length (L1= length, L2 = 0) 2 Discrete Lengths (L1 > L2) Length within Range (L1 <L2) Any length (L1 = L2 = 0)

L1 = 12 L2 = 0

EAN128/ Code128

EAN128 Enable/ Disable (ON/ OFF) ON

Code128 Enable/ Disable (ON/ OFF) ON

RSS Code RSS DISABLED/ RSS LIMITED/ RSS14/ RSS EXPANDED

DISABLED

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

Page 15: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

DEVICE PARAMETERS

PARAMETER COMMENTS DEFAULT

SOUND

Volume Enable/ Disable beeper (ON/ OFF) ON

Override OPN Volume

Enable/ Disable (ON/ OFF). When enabled OPN_DL will send the Default Override Volume Setting.

OFF

Default Override Vol-ume Setting

OFF/ HIGH/ MEDIUM/ LOW/ LOW+1/LOW+2

OFF

Host Connect Beep ON

Beeper Toggle Enable/ Disable feature allowing operator to toggle beeper ON/ OFF using scan key (ON/ OFF)

ON

Host Complete Beep ON/ OFF ON

BARCODE SCANNING

Max Barcode Length 1 - 30 30

Scanner on-time 1 - 10 Secs. (100mS increments) 30 (3 Secs)

Reject Redundant Barcode

OFF - Any code will be accepted

Mode1 - A code will be rejected if identical to previously scanned code

Mode 2 - A code will be rejected if identical to any previously scanned code

OFF

Good Decode LED On-time

250mS - 1 Sec (250mS increments) 4 (1 Sec.)

MEMORY

Auto Clear

Clear Barcodes after download (ON/ OFF) (Overrides the Clear After Download setting in OPN_DL)

OFF

Store RTC Store real-time clock data (ON/ OFF)

ON

Delete Enable Determines operation of recessed Delete key.

Clear All function (ON/OFF)/ Delete Barcode (ON/OFF)/ Set all to default (ON/OFF)

Thus a setting of ON/ OFF/ ON will enable Clear All, and Delete Barcode but disable Set All to default

ON/ON/ON

BATTERY

Low Battery Warning Determines how low battery condition will be handled. 0 = No operation 1 = Ignore low battery 2 = Indicate, laser turned off 3 = Indicate, operate normally

3

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

Store RTC Store DTS Output File Result

OFF OFF No DTS in file

OFF ON DTS = 01/01/0001 00:00:00

ON OFF No DTS in file

ON ON DTS = scanned date/time

Page 16: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

4.2 SAVING DISPLAYED CONFIGURATION TO DISK To save the displayed configuration to disk click the diskette icon from the menu bar

1) Click the Diskette icon to save the displayed configuration to disk

2) Specify the required location and name for the file and click Save

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

Page 17: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

4.3 RETRIEVING THE CONFIGURATION FROM DISK To load a configuration from disk click the windows ‘folder’ icon from the menu bar:

1) Click the Windows ’Folder’ icon to retrieve a saved configuration from disk

2) Select the file to be retrieved and click Open.

This will load the configuration into the OPN2001. The display will be updated to reflect the new settings.

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

Page 18: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

4.4 CLONING DEVICES To clone devices to the displayed configuration proceed as follows:

1) Click Clone

This will prevent OPN_DL from automatically extracting the configuration from connected de-vices, allowing the displayed configuration to be loaded to successive OPN2001s.

2) Connect the 1st OPN2001 to be cloned. The displayed configuration will automatically be loaded to the device

3) Configuration successfully loaded. Disconnect the OPN2001

4) Connect next OPN2001 to be cloned, or click Finish to exit from Cloning mode.

Note - Cloning device volume: The OPN2001 does not report its current bleeper volume to OPN_DL. This means that when cloning a device to a set of configuration parameters extracted from a ‘master’ device, all settings in the cloned device will match the master except for the bleeper vol-ume, which will be set to a default level.

The default level is set using the volume override parameter (see section 4.1). This allows a default volume level to be configured into the OPN_DL software which will be used when cloning devices.

Electronic Reading Systems Ltd Tel: 01234 855300 Fax: 01234 855446 www.ers-online.co.uk

Page 19: OPN DL UTILITY SOFTWARE INSTALLATION AND USER … · OPN_DL UTILITY SOFTWARE INSTALLATION AND USER GUIDE ... If written as an .xls document the data will be presented in Excel as:

5.0 Shutting Down OPN_DL It is necessary to disconnect the OPN2001 before closing the application.

1) Click ‘Close’

2) If necessary, disconnect OPN2001 and click OK