optical coherence tomography - uc davis health · optical coherence tomography (oct) is an optical...
TRANSCRIPT
![Page 1: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/1.jpg)
Optical Coherence Tomography
When Black and White TV Just Isn’t Good Enough
Jeffrey A Southard, MD
UC Davis Medical Center May 5, 2012
![Page 2: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/2.jpg)
• Consultant for Boston Scientific, Cordis, St Jude
![Page 3: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/3.jpg)
Imaging
![Page 4: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/4.jpg)
What is OCT?
4
Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images of tissue microstructure.
Key Features: Micrometer-level resolution Subsurface imaging High tissue contrast Safe, non-ionizing radiation
![Page 5: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/5.jpg)
C7-XR Dragonfly™ Imaging Catheter
Insertable length: 135 cm with
hydrophilic coating
Purge port with 3ml syringe
2.7 Fr tip diameter
(distal 28 cm) with hydrophilic coating Minirail tip compatible with .014”
guidewire
Optical fiber quick-connect
![Page 6: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/6.jpg)
Intravascular OCT
Flexible fiberoptic catheter used for light delivery
Catheter rotates to create image frames
Catheter pulls back to map vessel segment
Lesion analysis, stent planning, post-stent assessment, follow-up
6
![Page 7: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/7.jpg)
Image Generation Measure echo time
delay of reflected light waves
One pixel 5 x 19 um One axial line 1024
pixels One frame 500 axial
lines Optical resolution 15
axial, 20 to 40 um transverse
7
![Page 8: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/8.jpg)
Pullback Generation
One pullback 270 frames
8
![Page 9: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/9.jpg)
Intima Media
Adventitia
Normal Coronary Artery
Black and White TV
![Page 10: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/10.jpg)
Normal, Mild Intimal Thickening
![Page 11: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/11.jpg)
Calcified Plaque Signal poor (darker) Low backscatter Low attenuation Sharp edges
Circumferential Calcium C
Calcium Nodule
![Page 12: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/12.jpg)
Calcified Plaque with Rupture
![Page 13: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/13.jpg)
Lipid Top is bright Body is dark
High attenuation Diffuse edge
L
L
L L
![Page 14: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/14.jpg)
Fibrous Plaque
14
Homogeneous High backscatter, bright Finely textured Low attenuation
F
F
![Page 15: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/15.jpg)
Metallic stent struts (BMS & DES)
Bright inner surface reflection
Shadows behind
Stent Images
![Page 16: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/16.jpg)
F/U DES at 1 Mo F/U BMS
DES compared to BMS in OCT
![Page 17: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/17.jpg)
Red Thrombus
![Page 18: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/18.jpg)
Stent
Dissection
Edge Dissection
![Page 19: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/19.jpg)
Small Intimal Tear
![Page 20: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/20.jpg)
Zoom Feature (Magnify)
![Page 21: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/21.jpg)
![Page 22: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/22.jpg)
Tissue Penetration
22
![Page 23: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/23.jpg)
- 61 intermediate stenosis by angiography were assessed by FFR - FFR less than 0.80 was considered significant - OCT vs IVUS on these vessels for anatomic assessment - In vessels less than 3 mm in diameter OCT was superior to IVUS in
identifying functionally significant lesions - MLA for IVUS was 2.42 mm2 - MLD for IVUS was 1.55 mm2
![Page 24: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/24.jpg)
40 Mhz IVUS
Dissection – OCT vs. IVUS
![Page 25: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/25.jpg)
FD-OCT vs IVUS
25
Edge dissection during stent implantation
Neointimal growth on previously implanted stent at follow-up
![Page 26: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/26.jpg)
Stent malapposition: 10atm
Stent Underexpansion & Malapposition: OCT vs. IVUS
![Page 27: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/27.jpg)
Technical Comparison
27
Resolution Axial 15 µm 100 - 200 µm
Transverse 20 – 40 µm 200 - 300 µm Imaging Speed Rotational 100 frames/s 30 frames/s
Pullback 20 mm/s 0.5 - 1 mm/s
Scan Diameter 10 mm 15 mm (var)
Tissue Penetration 1 - 2 mm 6 -10 mm
OC
T
IVU
S
![Page 28: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/28.jpg)
What I Can’t Do With IVUS
1. Clearly see what I am doing 2. Image thrombus 3. Determine thin cap fibroatheroma (TCFA)
and hence possible vulnerable plaque 4. Visualize bio-absorbable stents 5. Visualize spontaneous dissection well 6. Determine measurements in small vessels < 3 mm with accuracy 7. Image the vessel in a timely fashion
![Page 29: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/29.jpg)
29
![Page 30: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/30.jpg)
Quotes
• “The high resolution OCT images provide a glimpse at structural detail not seen before by other imaging modalities. We believe that OCT has the potential to identify thin-cap fibro-atheromas, clearly highlight intraluminal thrombus, and assess the complete healing of novel drug-eluting stent designs. Volcano is committed to exploring the various clinical benefits of our OCT platform…”
Michael Lussier- President, Volcano Europe 2008
![Page 31: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/31.jpg)
• "Volcano is committed to being the leader in intravascular imaging…Our investment in this OCT product line underscores that commitment, and opens a series of new clinical applications and opportunities…”
• “a breakthrough that is the result of a 10 year development effort and an investment of over $150 million dollars…”
Scott Huennekens, President and Chief Executive Officer of Volcano 2008, 2009
![Page 32: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/32.jpg)
Final Thoughts
• IVUS is used more than OCT right now because OCT is new…
• Physicians don’t know how to interpret the OCT images at the present time
• Financial concerns • What do I do with what I find? - I can’t lie to my staff anymore…
![Page 33: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/33.jpg)
Beer Goggles… OCT vs. IVUS I’m Not Very Sure I Understand What I’m Seeing
![Page 34: Optical Coherence Tomography - UC Davis Health · Optical Coherence Tomography (OCT) is an optical imaging modality that uses near-infrared light to create high-resolution images](https://reader033.vdocument.in/reader033/viewer/2022053006/5f0a02d97e708231d42994e0/html5/thumbnails/34.jpg)
You Win! OCT is BETTER!