order price enquiry - aco nordic · 3. design please choose: surface treatment coating (sanding...
TRANSCRIPT
Order Price enquiry
ACO ShowerDrain C - individual configuration
Installer:
Street: City:
Tel.: Email:
ACO HaustechnikProjektierung DuschrinnenFax +49 (0) 3 69 65 /81 9-3 69E-Mail: [email protected]
Sales representative:
Date:
Object (no., name, location):
Dealer/contact partner:
Handling code/document no.:
Tel.: Email:
If you require a quotation, please fill in this two-page configura-tion, print and send to the following fax number or print as PDF file and send to the following email address:
1. Socket inclination gully bodies (indications installation height)
Please choose:
Vertical outlet (90° inclination)without water seal (WS), ND 50shower channel installation height 18 mm (HInstallation)
H In
stal
latio
n
12
H
Inst
alla
tion
Horizontal outlet (1.5° inclination)Water seal = 50 mm, ND 50shower channel installation height 92 mm (HInstallation)
H In
stal
latio
n
12
H
Inst
alla
tion
Horizontal outlet (1.5° inclination)Water seal = 30 mm, ND 50shower channel installation height 65 mm (HInstallation)
2a. Room installation (max. length = 2200 mm, standard width = 70 mm)
30 30
12
L1L2
70
30L1 = ............. mm ( max. 2200 mm)L2 = ............. mm ( max. 2260 mm)
4-sided revolving thin bed flange
2b. Wall installation (max. length = 2200 mm, standard width = 70 mm)
3013
20
12
L1L2
70
30 30L1 = ............. mm ( max. 2200 mm)L2 = ............. mm ( max. 2260 mm)
3-sided thin bed flangeWall flange at rear
2c. Without flange (max. length = 2200 mm, standard width = 70 mm)
L1
70
L1 = ............. mm ( max. 2200 mm)
3. Design
Please choose:
Surface treatment Coating (sanding flange) Fixation
etched yes concrete anchor
electropolished noheight-adjustable mounting angle (55 mm)
4. Number and position of drain bodies
Min./max. length indications, also applies to vertical design:
Lmin 250 mmLmax 700 mm
Lmin 460 mmLmax 700 mm
Lmin 250 mmLmax 700 mm
For drain values as per DIN EN 1253-1 the max. flow distance of water may NOT exceed 700 mm.
Please choose:
Outletcentrally
Oneoutlet L3 L4
S1
L3 = ............. mm L4 = ............. mm
S1 = front / back
Twooutlets
L3 L4 L5S1
S2 L3 = ............. mm / L4 = ............. mm L5 = ............. mm
S1 = front / backS2 = front / back
Threeoutlets L3 L5 L6
S1
S3
S2L4
L3 = ............. mm / L4 = ............. mm L5 = ............. mm / L6 = ............. mm
S1 = front / backS2 = front / backS3 = front / back
5. Design gratings (gratings as from 1400 mm two-part)
Please tick:
Wave Square Massive
Tile Slot