ObjectivesObjectives
Perform alarm query complying with requ
ests.
Understand the basic concepts of alarm,
such as alarm level, alarm type, etc.
Perform the alarm configuration correctly.
Upon completion of this course,you will be able to:
![Page 3: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/3.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Course ContentsCourse Contents
Chapter 1 Alarm Management Description
Chapter2 Alarm Query
Chapter3 Alarm Maintenance
Chapter4 Alarm Box Management
Chapter5 BTS Near-end Alarm Management
![Page 4: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/4.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Structure of Alarm Management SystemStructure of Alarm Management System
Radio layer Alarm
Alarm detection
CMUX Alarm management
Exchange
Alarm storage query MM
L Server
Alarm filtration forwarding
Alarm processing
BAM
BSC FAM
Transport layer Alarm
Com
munication
Gatew
ay
Alarm
Box
BTS FAM OMU
Alarm Box
![Page 5: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/5.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Basic ConceptsBasic Concepts
Event AlarmFault Alarm
Alarm TypeAlarm Type
Event AlarmFault AlarmRecovery Alarm
Alarm TypeAlarm Type
The fault alarm and recovery alarm should occur in pairs.
![Page 6: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/6.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Basic ConceptsBasic Concepts
Critical LevelMajor LevelMinor LevelWarning Level
Alarm LevelAlarm Level
•It indicates the severity of the alarm. •The highest level is the critical level.
![Page 7: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/7.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Basic ConceptBasic Concept
Used to identify the category of alarm.
Alarm IDAlarm ID
Used to identify the sequence of alarms generated.
Alarm Sequence NumberAlarm Sequence Number
![Page 8: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/8.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Course ContentsCourse Contents
Chapter 1 Alarm Management Description
Chapter2 Alarm Query
Chapter3 Alarm Maintenance
Chapter4 Alarm Box Management
Chapter5 BTS Near-end Alarm Management
![Page 9: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/9.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Alarm Query CommandsAlarm Query Commands
LST ALMFE
LST ALMLOG
LST NEALMLOG
LST ALMINF
LST ALMCFG
![Page 10: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/10.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Query the Current AlarmsQuery the Current Alarms
Example: To query the current alarms ( including fault alarms and event alarms) in the system and return a maximum of 100 results .Command: LST ALMFE : CNT=100;
![Page 11: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/11.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Query RAC History AlarmQuery RAC History Alarm
Example 1: Query history alarms of RAC. Alarm level: cirtical
and major alarms. Up to 200 records will be returned when th
e alarm level are “Critical” and “Major” for history alarm query.
Command: LST ALMLOG: ALMTP=flt, ALVL=EMERGENCY-
1&IMPORTANT-1&COMMON-0&NOTIFICATION-0, CNT=20
0;
![Page 12: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/12.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Difference Between Current Alarm and History Alarm
Difference Between Current Alarm and History Alarm
Current Alarm: The current alarm refers to a fault alarm or an
event alarm that has not been recovered or acknowledged .
History Alarm: All alarms generated in the system, including
fault alarms and event alarms, whether recovered or
confirmed are called history alarms.
![Page 13: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/13.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Query Information of History Alarm of the BTS Query Information of History Alarm of the BTS
Example 1: Query all the history alarms with alarm level of em
ergency alarm & common alarm of the BTSs from No. 10 to N
o. 13, at most 200 records are required.
Command: LST NEALMLOG: STARTNEID=10, ENDNOEID=
13, ALMTP=flt, ALVL=EMERGENCY-1&IMPORTANT-0&CO
MMON-1&NOTIFICATION-0, CNT=200;
![Page 14: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/14.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Query Alarm Detailed Information Query Alarm Detailed Information
The serial No. of the alarm is the only command parameter
that needs to be input..
Example: Query the detailed information of the alarm whose
serial No. is 2200.
Command: LST ALMINF: CSN=2200;
![Page 15: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/15.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Query Alarm Configuration InformationQuery Alarm Configuration Information
Example1: Query the configuration information of the alarms
whose IDs are between 100 and 200.
Command: LST ALMCFG: STARTAID=100, ENDAID=200;
![Page 16: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/16.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Course ContentsCourse Contents
Chapter 1 Alarm Management Description
Chapter2 Alarm Query
Chapter3 Alarm Maintenance
Chapter4 Alarm Box Management
Chapter5 BTS Near-end Alarm Management
![Page 17: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/17.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Alarm Management CommandsAlarm Management Commands
RMV ALMFLT
RMV ALMLOG
SET ALMACK
SET ALMLVL
SET ALMMSK
SET CLTRPT
![Page 18: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/18.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Manually Reset AlarmManually Reset Alarm
Example: Manually recover the alarms whose serial No. is between 111 and 222.Command: RMV ALMFLT: STARTCSN=111, ENDCSN=222;
![Page 19: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/19.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Delete History AlarmDelete History Alarm
Example1: Delete history alarms generated during the days b
etween 2001-02-03 and 2001-02-05.
Command:RMV ALMLOG: SD=2001&02&03, ED=2001&02&
05;
![Page 20: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/20.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Alarm ConfirmationAlarm Confirmation
Example1: Confirm alarms whose serial No. is between 2000
and 2100.
Command:SET ALMACK: STARTCSN=2000, ENDCSN=2100;
![Page 21: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/21.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Set Alarm LevelSet Alarm Level
Example1: Set alarm level as “Major” for alarms whose ID is
between 100 and 200.
Command: SET ALMLVL: STARTAID=100, ENDAID=200,
NEWALVL=IMPORTANT;
![Page 22: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/22.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Set Alarm Shielding FlagSet Alarm Shielding Flag
Example1: Shield alarms whose IDs are between 50 and 80.
Command: SET ALMMSK: STARTAID=50, ENDAID=80,
MSKFLG=MASK;
the system will not store and display the shielded alarms.
![Page 23: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/23.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Example 1: Set alarms whose ID is between 100 and 120 not
to be reported to the client.
Command:
SET CLTRPT: STARTAID=100, ENDAID=120,
RPTFLG=NONRPT;
Set Alarm ReportSet Alarm Report
![Page 24: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/24.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Difference Between SET ALMMSK & SET CLTRPT Difference Between SET ALMMSK & SET CLTRPT
If SET ALMMSK is executed, the foreground will not stored
corresponding alarms. And the alarms could not be queried by
command “LST ALMLOG” or “LST ALMLOG”, but the execution
result of “SET CLTPRT” is not in this case.
The alarms will be sent to alarm box even if ”SET CLTRPT” is
executed.
![Page 25: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/25.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Course ContentsCourse Contents
Chapter 1 Alarm Management Description
Chapter2 Alarm Query
Chapter3 Alarm Maintenance
Chapter4 Alarm Box Management
Chapter5 BTS Near-end Alarm Management
![Page 26: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/26.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Configuration of Communication GatewayConfiguration of Communication Gateway
![Page 27: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/27.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Query Alarm Indicator StatusQuery Alarm Indicator Status
Example: Query the status of the current alarm indicator. Command: LST BOXLGT:;The information returned from the system is as follows:%%LST BOXLGT:;%%RETCODE = 0 Execution succeededCritical : 3 Alarm Major : 14 Alarm Minor 0 Alarm Warning |#|#| 0 Alarm
![Page 28: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/28.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Manually Switch Off Alarm IndicatorManually Switch Off Alarm Indicator
Example: Switch off the alarm box indicator of “Warning”
alarms.
Command: CLR BOXLGT: ALVL=NOTIFICATION;
![Page 29: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/29.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Stop Alarm Sound Stop Alarm Sound
Example: Stop the alarm sound
Command: STP BOXSND:;
![Page 30: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/30.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Query Alarm Indicator StatusQuery Alarm Indicator Status
Example: Query the status of the current alarm indicator. Command: LST BOXLGT:;The information returned from the system is as follows:%%LST BOXLGT:;%%RETCODE = 0 Execution succeededCritical : 3 Alarm Major : 14 Alarm Minor 0 Alarm Warning |#|#| 0 Alarm
![Page 31: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/31.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Reset Alarm BoxReset Alarm Box
Example: Reset alarm box
Command:
RST ALMBOX:;
![Page 32: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/32.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Course ContentsCourse Contents
Chapter 1 Alarm Management Description
Chapter2 Alarm Query
Chapter3 Alarm Maintenance
Chapter4 Alarm Box Management
Chapter5 BTS Near-end Alarm Management
![Page 33: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/33.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Query BTS Current AlarmQuery BTS Current Alarm
LST CURALM[:BRDTP=<BCIM>][,BRDID=<0>][,BGNDT=<2000&1&1
>][,BGN TM=<0&0&0>][,END DT=<2005&12&31>][,END
TM=<23&59&59 >][,ALARM CODE=<255>][,SUBUNIT TYPE=<255>]
[,SUBUNIT NO=<255 >][,ALARM DESCRIP="<STRING>"]
![Page 34: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/34.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Query BTS History Alarm Query BTS History Alarm
LST HISALM[:BRDTP=<BCIM>][,BRDID=<0>][,BGN
DT=<2000&1&1 >][,BGN TM=<0&0&0>][,END
DT=<2005&12&31>][,END TM=<23&59&59 >][,ALARM
CODE=<255>][,ALARM TYPE=<ALL>][,SUBUNIT
TYPE=<255 >][,SUBUNIT NO=<255>][,ALARM
DESCRIP="<STRING>"]
![Page 35: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/35.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
Delete BTS History Alarm Delete BTS History Alarm
DEL HISALM[:BRDTP=<BCIM>][,BRDID=<0>][,BGN
DT=<2000&1&1 >][,BGN TM=<0&0&0>][,END
DT=<2005&12&31>][,END TM=<23&59&59 >][,ALARM
CODE=<255>][,ALARM TYPE=<ALL>][,SUBUNIT
TYPE=<255 >][,SUBUNIT NO=<255>][,ALARM
DESCRIP="<STRING>"]
![Page 36: ORI005301 RAC6610 Alarm System ISSUE 1.1](https://reader035.vdocument.in/reader035/viewer/2022062614/546ac75ab4af9f6b2c8b487a/html5/thumbnails/36.jpg)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
SummarySummary
Alarm Management Description
Alarm Query
Alarm Maintenance
Alarm Box Management
BTS Near-end Alarm Management