4
Protherm
Industry Standards
• UL Listed (File # SA12046)• Indoor: NEMA 12• Outdoor: NEMA 3R, 4 and 4X (optional)
Industries Served
• Industrial & Process Automation• Packaging and Logistical Systems• Energy (Solar, Wind, Water and Petrochemical)• Telecommunications• Water / Wastewater Systems• Defense Systems
Product Attributes
• 7 Sizes of Air Conditioners; Capacity Range from 1,300 BTU to 20K BTU• Voltage Options: 48VDC, 115VAC, 230VAC and 460VAC 3Phase• Operating Temperatures:
- Indoor: 20°C/68°F to 55°C/131°F- Outdoor: -40°C/-40°F to 55°C/131°F
• All Models Powder Coated RAL7035• R134a Earth Friendly Refrigerants Used• All Units Functionally Tested Before Shipment
5 6
Design Features
• 380 Watts – 6000 Watts
• Micro Channel Condensing Coil (Model 11 and larger)
- Full Aluminum Design
- Corrosion Protection (Standard on CVO Models)
- Filterless Design
- Eliminates Coil Oxidation
• Low Ambient Packages (Standard on CVO Models)
• Passive Condensate Management
• Simplified Mounting Design
• Optional Heater Packages (1kW / 3kW)
Digital Controller
• All Models except CVE03
• Sequencing (Lead/Lag)
• Modbus
• Alarm Functions
• Remote Door Switch Capable
• Remote Display (Standard on CVO Models)
• Short Cycle Protection
us.stulz-cosmotec.com800-465-9241 Information / Drawings subject to change without notice5 5
Air Conditioners - Protherm
6
It has been said that great things come in small packages, and Cosmotec’s Microchannel Condenser Coils are no exception. Cosmotec has developed a condenser technology for air conditioners that allows us to save space, use less refrigerant, reduce weight, minimize coil oxidation and increase performance all at the same time. By adapting philosophies from the Automotive Industry we have developed our new Micro Channel Condensing Coil to improve the performance of our air conditioners.
• Smaller Footprint (40% of Original Design)• Lighter Weight• Reduction of Refrigerant volume• Reduced Maintenance• Elimination of Coil Oxidation• Improved Performance
Micro Channel Condenser Coils: The big benefit of a smaller package
Parallel Flow Tubes
Header
Enhanced Aluminum Fins
MicroChannel Design
Sequencing cable(ACASEQ)
Serial port for Modbus(ACASPM)
Smart Energy2 Management probe(ACARES)
SAVING ENERGY
Stainless steel housing 304/316
Epoxy or cataphoresis treatment condenser coil (standard on outdoor models)
Electrical heater1kW (CVO11 & larger)3kW (CVO40)
Special ColorAir Filter
Display for Protherm Models(standard on all models except Model 03)
Options:
us.stulz-cosmotec.com800-465-9241 Information / Drawings subject to change without notice
CVO05Specification CVO05U12038000 CVO05U12208000 CVO05U1203800I CVO05U1220800I CVO05U12128000 CVO05U1212800I
Power Supply - V-Ph-Hz 115-1-60 230-1-50/60 115-1-60 230-1-50/60 48VDC 48VDC
Cooling Capacity L35L35 - W(BTU) 580 (1,979) 580 (1,979) 500 (1,706)
Cooling Capacity L35L50 - W(BTU) 430 (1,467) 430 (1,467) 350 (1,194)
Stainless Steel - 304 N/A • • N/A •
Optional Heater N/A
Dimensions - mm 634.5 x 313 x 235.5
Dimensions - in 25 x 12.3 x 9.3
Max Running Current / Starting Current - A 4 / 30 1.5 / 15 4 / 30 1.5 / 15 6.1 / -
Power Consumption L35L50 - W 340 340 300
Air Flow (free blowing) - m3/h(CFM) 195 (115) 195 (115) 450 (265)
Regulation Temperature Limits - °F 77° to 113°
Ambient Temperature Limits - °F -40° to 131°
Protection Level Type 4 Type 4X Type 4 Type 4X
Noise Level - dB(A) 61 61 67
Weight - kg (lbs) 23 (51)
CVO08Specification CVO08U12038000 CVO08U12208000 CVO08U1203800I CVO08U1220800I
Power Supply - V-Ph-Hz 115-1-60 230-1-50/60 115-1-60 230-1-50/60
Cooling Capacity L35L35 - W (BTU) 900 (3,070) 900 (3,070)
Cooling Capacity L35L50 - W (BTU) 700 (2,388) 700 (2,388)
Stainless Steel - 304 N/A • •
Optional Heater N/A
Dimensions - mm 634.5 x 313 x 235.5
Dimensions - in 25 x 12.3 x 9.3
Max Running Current / Starting Current - A 5.2 / 34 4 / 20 5.2 / 34 4 / 20
Power Consumption L35L50 - W 600 600
Air Flow (free blowing) - m3/h (CFM) 390 (230) 390 (230)
Regulation Temperature Limits - °F 77° to 113°
Ambient Temperature Limits - °F -40° to 131°
Protection Level Type 4 Type 4X
Noise Level - dB(A) 65
Weight - kg (lbs) 27 (60)
CVO11Specification CVO11U12038000 CVO11U12208000 CVO11U1203800I CVO11U1220800I
Power Supply - V-Ph-Hz 115-1-60 230-1-50/60 115-1-60 230-1-50/60
Cooling Capacity L35L35 - W (BTU) 1,150 (3,923) 1,150 (3,923)
Cooling Capacity L35L50 - W (BTU) 890 (3,036) 890 (3,036)
Stainless Steel - 304 N/A • •
Optional Heater 1kW 1kW
Dimensions - mm 906 x 410 x 272
Dimensions - in 35.7 x 16.1 x 10.7
Max Running Current / Starting Current - A 6.4 / 34 2.8 / 16 6.4 / 34 2.8 / 16
Power Consumption L35L50 - W 650 650
Air Flow (free blowing) - m3/h(CFM) 580 (341) 580 (341)
Regulation Temperature Limits - °F 77° to 113°
Ambient Temperature Limits - °F -40° to 131°
Protection Level Type 4 Type 4X
Noise Level - dB(A) 65
Weight - kg (lbs) 44 (97)
• All CVO units are
9
Outdoor Air Conditioners - Protherm
910
Air Technology Systems, Inc.
800-465-9241Information / Drawings subject to change without noticeus.stulz-cosmotec.com
Outdoor Air Conditioners - Protherm
10 11
CVO15Specification CVO15U12038000 CVO15U12208000 CVO15U12628000 CVO15U1203800I CVO15U1220800I CVO15U1262800I
Power Supply - V-Ph-Hz 115-1-60 230-1-50/60 400/460-3-50/60 115-1-60 230-1-50/60 400/460-3-50/60
Cooling Capacity L35L35 - W (BTU) 1,600 (5,459) 1,500 (5,118) 1,600 (5,459) 1,500 (5,118)
Cooling Capacity L35L50 - W (BTU) 1,280 (4,367) 1,200 (4,094) 1,280 (4,367) 1,200 (4,094)
Stainless Steel - 304 N/A N/A • • •
Optional Heater 1 kW N/A 1 kW N/A
Dimensions - mm 906 x 410 x 272 996 x 409 x 286 906 x 410 x 272 996 x 409 x 286
Dimensions - in 35.7 x 16.1 x 10.7 39.2 x 16.1 x 11.3 35.7 x 16.1 x 10.7 35.7 x 16.1 x 11.3
Max Running Current / Starting Current - A 9.5 / 32 4.2 / 17 2.5 / 16 9.5 / 32 4.2 / 17 2.5 / 16
Power Consumption L35L50 - W 825 890 825 890
Air Flow (free blowing) - m3/h (CFM) 580 / 341 580 / 341
Regulation Temperature Limits - °F 77° to 113°
Ambient Temperature Limits - °F -40° to 131°
Protection Level Type 4 Type 4X
Noise Level - dB(A) 65 65
Weight - kg (lbs) 46 (101) 48 (106) 46 (101) 48 (106)
CVO20Specification CVO20U12038000 CVO20U12208000 CVO20U12628000 CVO20U1203800I CVO20U1220800I CVO20U1262800I
Power Supply - V-Ph-Hz 115-1-60 230-1-50/60 400/460-3-50/60 115-1-60 230-1-50/60 400/460-3-50/60
Cooling Capacity L35L35 - W (BTU) 2,200 (7,506) 2,100 (7,165) 2,200 (7,506) 2,100 (7,165)
Cooling Capacity L35L50 - W (BTU) 1,850 (6,312) 1,800 (6,141) 1,850 (6,312) 1,800 (6,141)
Stainless Steel - 304 N/A N/A N/A • • •
Optional Heater 1kW N/A 1kW N/A
Dimensions - mm 996 x 409 x 286
Dimensions - in 39.2 x 16.1 x 11.3
Max Running Current / Starting Current - A 11.5 / 65 7.3 / 34 2.6 / 18 11.5 / 65 7.3 / 34 2.6 / 18
Power Consumption L35L50 - W 1240
Air Flow (free blowing) - m3/h(CFM) 930 (547)
Regulation Temperature Limits - °F 77° to 113°
Ambient Temperature Limits - °F -40° to 131°
Protection Level Type 4 Type 4X
Noise Level - dB(A) 68
Weight - kg (lbs) 48 (106)
CVO40 CV060Specification CVO40U12208000 CVO40U12628000 CVO40U1220800I CVO40U1262800I CV06U12628000 CV06U1262800I
Power Supply - V-Ph-Hz 230-1-50/60 400/460-3-50/60 230-1-50/60 400/460-3-50/60 460-3-60
Cooling Capacity L35L35 - W (BTU) 4,100 (13,989) 4,050 (13,819) 4,100 (13,989) 4,050 (13,819) 5,950 (20,300)
Cooling Capacity L35L50 - W (BTU) 3,300 (11,260) 3,260 (11,123) 3,300 (11,260) 3,260 (11,123) 4,850 (16,550)
Stainless Steel - 304 N/A N/A • • N/A •
Optional Heater 1kW or 3kW N/A 1kW or 3kW N/A N/A
Dimensions - mm 1211 x 511 x 356 1400 x 555 x 416
Dimensions - in 47.7 x 20.1 x 14 55 x 22 x 16
Max Running Current / Starting Current - A 10.5 / 46.5 3.5 / 18 10.5 / 46.5 3.5 / 18 8.11
Power Consumption L35L50 - W 1950 3,600
Air Flow (free blowing) - m3/h (CFM) 1300 (765) 1,600 (942)
Regulation Temperature Limits - °F 77° to 113° 77° to 113°
Ambient Temperature Limits - °F -40° to 131° -40° to 131°
Protection Level Type 4 Type 4X Type 4 Type 4X
Noise Level - dB(A) 70 71
Weight - kg (lbs) 86 (189) 100 (220)
• All CVO units are
us.stulz-cosmotec.com800-465-9241 Information / Drawings subject to change without notice
235.6314
634.
5
634.
5
235.6314313.524235.8 35.8
16.5
463
162.
5
316
132
142
20.5
642
31.5
280
260 26.826.8
16.816.8
313.524235.8 35.8
16.5
463
162.
5
316
142
20.5
642
31.5
280
260 26.826.8
16.816.8
132
906
410 27241031647 47
690
84.5
164
37119.5 19.5 24.5
316
913
240
108.
5
198.
5
340 3535
996
409 28641031647 47
690
84.5
164
37119.5 19.5
24.5
316
1005
240
200.
5
290.
5
340 3535
1211
511 356 51242046 46
940
179
24.5
24.5
400
530
85.5 25
4.5
430 4141
39061 61
41031647 47
690
84.5
164
37119.5 19.5 24.5
316
913
240
108.
5
198.
5
340 3535
272410
906
•M
easu
rem
ents
sho
wn
in m
m (r
efer
to
page
s 10
-11
for
in.)
*The dimensions for the CVO15U12628000(I) are the same as the CVO20 dimensions
CVO05 CVO08
CVO11 CVO15*
CVO20 CVO40
11
CVO60
1400
555 416
556
340
46247 47
43859 59
47242 42
340
179
24.5
431
91.5
1000
25.5
380.
5
1112
Outdoor Air Conditioners - Protherm
Air Technology Systems, Inc.
800-465-9241Information / Drawings subject to change without noticeus.stulz-cosmotec.com12 14
Coo
ling
Cap
acity
Ambient Temperature20 25 30 35 40 45 50 55
Inside Cabinet
Temperature
°C (°F)
Performance (115V/230V)850800750700650600550500450400350300250250
300350400450500550600650700750800850
20 25 30 35 40 45 50 55
CoolingCapacity
Ambient Temperature
CVE05(115V/230V)
25
30
35
40
45
Cabinet Temperature
°C
45 (113) 40 (104) 35 (95) 30 (86) 25 (77)
°F400
500
600
700
800
900
1000
1100
1200
1300
20 25 30 35 40 45 50 55
CoolingCapacity
Ambient Temperature
CVE08(115V/230V)
25
30
35
40
45
Cabinet Temperature
1300
1200
1100
1000
900
800
700
600
500
400
Coo
ling
Cap
acity
Ambient Temperature20 25 30 35 40 45 50 55
Inside Cabinet
Temperature
°C (°F)
Performance (115V/230V)
°C
45 (113) 40 (104) 35 (95) 30 (86) 25 (77)
°F
Coo
ling
Cap
acity
Ambient Temperature20 25 30 35 40 45 50 55
Inside Cabinet
Temperature
°C (°F)
Performance (115V/230V)1750
1600
1450
1300
1150
1000
850
700
550550
700
850
1000
1150
1300
1450
1600
1750
20 25 30 35 40 45 50 55
CoolingCapacity
Ambient Temperature
CVE11(115V/230V)
25
30
35
40
45
Cabinet Temperature
°C
45 (113) 40 (104) 35 (95) 30 (86) 25 (77)
°F
Coo
ling
Cap
acity
Ambient Temperature20 25 30 35 40 45 50 55
Inside Cabinet
Temperature
°C (°F)
Performance (115V/230V)2400225021001950180016501500135012001050
9009001050
1200
1350
1500
1650
1800
1950
2100
2250
2400
20 25 30 35 40 45 50 55
CoolingCapacity
Ambient Temperature
CVE15(115V/230V)
25
30
35
40
45
Cabinet Temperature
°C
45 (113) 40 (104) 35 (95) 30 (86) 25 (77)
°F
Coo
ling
Cap
acity
Ambient Temperature20 25 30 35 40 45 50 55
Inside Cabinet
Temperature
°C (°F)
Performance (115V/230V)3000
2800
2600
2400
2200
2000
1800
1600
14001400
1600
1800
2000
2200
2400
2600
2800
3000
20 25 30 35 40 45 50 55
CoolingCapacity
Ambient Temperature
CVE20(115V/230V)
25
30
35
40
45
Cabinet Temperature
°C
45 (113) 40 (104) 35 (95) 30 (86) 25 (77)
°F
Coo
ling
Cap
acity
20 25 30 35 40 45 50 55
Inside Cabinet
Temperature
°C (°F)
Performance (230V)5500520049004600430040003700340031002800250022002200
2500
2800
3100
3400
3700
4000
4300
4600
4900
5200
5500
20 25 30 35 40 45 50 55
CoolingCapacity
Ambient Temperature
CVE40(115V/230V)
25
30
35
40
45
Cabinet Termperature
°C
45 (113) 40 (104) 35 (95) 30 (86) 25 (77)
°F
CVO05 CVO08
CVO11 CVO15*
CVO20 CVO40
CVO60
3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
20 25 30 35 40 45 50 55
CoolingCapacity
Ambient Temperature
CVE60(460VAC)
25
30
35
40
45
Cabinet Temperature
Coo
ling
Cap
acity
Ambient Temperature20 25 30 35 40 45 50 55
8000
7500
7000
6500
6000
5500
5000
4500
4000
3500
Inside Cabinet
Temperature °C
(°F)
Performance (460VAC)
°C
45 (113) 40 (104) 35 (95) 30 (86) 25 (77)
°F
Outdoor Air Conditioners - Protherm
Air Technology Systems, Inc.
800-465-9241Information / Drawings subject to change without noticeus.stulz-cosmotec.com
Cosmotec Industrial Cooling, a part of STULZ Air Technology Systems, Inc.1572 Tilco Drive, Frederick, Maryland 21704
Phone: 800-465-9241Service: 888-529-1266
E-mail: [email protected]
us.stulz-cosmotec.comthermal.stulz-cosmotec.com
© October 2015 Technical data subject to change without notice.
®b y S T U L Z A i r T e c h n o l o g y S y s t e m s , I n c .
Production Facilities: U.S.A. • Germany • Italy • China • India On-Site Product Support: Worldwide
globally close to you
ISO-9001 Quality RegisteredISO9001Registered
Quality System
U.S.A.
Germany
Italy
India
China
STULZ Global Presence
(Thermal Calculation Tool)