OutlineOutline
• Classroom – Introduction– Terminology– Respirator Program
• Hands-on – Cleaning– Inspection– Fit testing
![Page 3: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/3.jpg)
Training GoalsTraining Goals
• You should understand the extent of the requirements of a respiratory protection program.
• You should understand the limitations of the program and your respirator.
![Page 4: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/4.jpg)
Permissible PracticesPermissible Practices
• Engineering and administrative controls before respirators.
• Engineering: substitution, minimization, isolation, ventilation controls.
• Administrative: scheduling or rotation of work.
• Maintenance and Research are areas where respirator use is still fairly common.
![Page 5: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/5.jpg)
ExposureExposure
• Exposure is the concentration of air contaminant
![Page 6: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/6.jpg)
According to MSDS for Hydrochloric Acid, recommended Personal Protective Equipment should include:
– Chemical goggles or face shield.
– Chemical resistant gloves. – Clothing, to avoid skin
contact. – Respiratory protection
based on airborne levels of acid vapor.
Exposure Assessment: Exposure Assessment: Hydrochloric AcidHydrochloric Acid
![Page 7: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/7.jpg)
Exposure Assessment: Exposure Assessment: Muriatic AcidMuriatic Acid
According to MSDS for muriatic acid, recommended personal protective equipment should include:
• Chemical goggles or face shield and chemical goggles.
• Chemical resistant gloves• Coveralls, boots, or apron
to avoid skin contact. • Respiratory protection
based on airborne levels of contaminants.
![Page 8: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/8.jpg)
Process SelectionProcess Selection
• Physical Plant’s respirator program has a complete “process selection” chart in your handouts
• Power Plant hasn’t developed such a tool yet.
• Other departments – ?
![Page 9: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/9.jpg)
Exposure AcronymsExposure Acronyms
• PELPEL - Permissible Exposure Limit
• TWATWA - Time Weighted Average
• STELSTEL - Short Term Exposure Limit
• C C - Ceiling Limit
• TLV TLV - Threshold Limit Value
• IDLH IDLH - Immediately Dangerous to Life and Health
• ALAL - Action Level
![Page 10: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/10.jpg)
Explanation of Exposure TermsExplanation of Exposure TermsB
lan
k C
har
t
![Page 11: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/11.jpg)
Exposure ChartExposure ChartS
easo
ned
Wo
rker
![Page 12: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/12.jpg)
Exposure ChartExposure ChartS
up
ervi
sor
![Page 13: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/13.jpg)
Exposure Chart Exposure Chart O
uts
ide
Co
ntr
acto
r
![Page 14: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/14.jpg)
Asbestos Exposure LimitsAsbestos Exposure Limits
![Page 15: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/15.jpg)
Types of Respirators: FitTypes of Respirators: Fit
• Tight-fitting• Loose-fitting
![Page 16: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/16.jpg)
Tight fitting respiratorsTight fitting respirators
![Page 17: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/17.jpg)
QuickLatch RespiratorQuickLatch Respirator
• The only respirator with the easy on and off latching system. Just flip the latch and the respirator slides off the face. Close the latch and the respirator slides back into its original fitting position.
![Page 18: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/18.jpg)
Loose-fitting respiratorsLoose-fitting respirators
![Page 19: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/19.jpg)
Classes of Respirators:Classes of Respirators:Positive and Negative PressurePositive and Negative Pressure
• Positive pressurePositive pressure– The sandblasting helmet
system is a positive pressure respirator
• Negative pressureNegative pressure– North 7700 is a negative
pressure respirator– Disposable masks
![Page 20: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/20.jpg)
Positive Pressure RespiratorsPositive Pressure Respirators
• When inhaling, the pressure inside the respirator is kept higher than outside the respirator
![Page 21: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/21.jpg)
Examples: positive pressure respiratorsExamples: positive pressure respirators
• Powered air purifying respirator
![Page 22: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/22.jpg)
Examples: positive pressure respiratorsExamples: positive pressure respirators
![Page 23: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/23.jpg)
Examples: positive pressure respiratorsExamples: positive pressure respirators
• Atmosphere supplying respirator– Supplied air respirators– Self-contained breathing apparatus
![Page 24: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/24.jpg)
Examples: escape-only respiratorsExamples: escape-only respirators
• Can not be used for entry
![Page 25: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/25.jpg)
Negative Pressure RespiratorsNegative Pressure Respirators
• When inhaling, the pressure inside the respirator is less than outside the respirator
![Page 26: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/26.jpg)
Examples: negative pressure respiratorsExamples: negative pressure respirators
• Filtering facepieces or Dust masks
![Page 27: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/27.jpg)
Examples: negative pressure respiratorsExamples: negative pressure respirators
• Use for sensitizers like allergens?
• Immunologic asthma develops after a variable period of time during which "sensitization" to an agent present in the workplace takes place
• If sensitization occurs, it may follow the first exposure, or may not occur until after exposure has continued for a long time.
![Page 28: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/28.jpg)
Voluntary and Mandatory Voluntary and Mandatory
• Dust masks are being used for protection against biological agents such as Anthrax
• Voluntary Use– One page OSHA
mandatory “Voluntary Use” form required
• Mandatory use of dust masks kick in the full respirator requirements
![Page 29: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/29.jpg)
Examples: negative pressure respiratorsExamples: negative pressure respirators
• Air-purifying respirator– North 7700
![Page 30: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/30.jpg)
Negative Pressure Respirators: filtersNegative Pressure Respirators: filters
• Color coded• Made specific for a
single manufacturers line of respirators
![Page 31: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/31.jpg)
Filters used against dust: HEPAFilters used against dust: HEPA
• High Efficiency Particulate Air (magenta ???)
• HEPA-only or combination filter
• Pancake
![Page 32: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/32.jpg)
Filters used against vapors: Filters used against vapors: Cartridges or Canisters Cartridges or Canisters
• Cartridges are the most common type.– OV (black)– OV/AG (bl/yellow)– OV/HEPA– OV/AG/pancake
HEPA
![Page 33: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/33.jpg)
Filters used against vapors: Cartridges or Filters used against vapors: Cartridges or CanistersCanisters
• Photo from cover of Chronicle of Higher Education
![Page 34: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/34.jpg)
Respirators in the NewsRespirators in the News
• Soldiers prepared for chemical warfare during Gulf War
(photo from Science magazine, Feb. 2001)
![Page 35: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/35.jpg)
Service LifeService Life
• End of service life indicators– mercury
• Service life calculations
![Page 36: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/36.jpg)
• Exertion Level• Cartridge Variability• Temperature• Humidity• Multiple Contaminants
Factors that can Reduce Cartridge Factors that can Reduce Cartridge Service LifeService Life
![Page 37: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/37.jpg)
Cartridge Service Life EstimatesCartridge Service Life Estimates
![Page 38: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/38.jpg)
Fit factorsFit factors
• We’ll talk about this at the end, if time permits.
Particulate Respirator
Combination Respirator
Gas & Vapor Respirator
![Page 39: Outline Classroom –Introduction –Terminology –Respirator Program Hands-on –Cleaning –Inspection –Fit testing](https://reader030.vdocument.in/reader030/viewer/2022032707/56649e0a5503460f94af257a/html5/thumbnails/39.jpg)
Latex AllergyLatex Allergy
• Latex allergy can result from repeated exposures to proteins in natural rubber latex. Exposure can be due to skin contact with a latex-containing item or inhalation of the proteins. Reactions can range from skin rash to anaphylaxis and shock. Some items that include latex are gloves, medical supplies, respirators, rubber bands, balloons, and baby bottle nipples.
• Respirators are available in rubber and silicone. The silicone masks can be used by those with latex sensitivities