outline of case study reports -...

15
BenchValue WP4 - case study overview: Ireland Project meeting: Vienna, Austria. 23 rd October, 2019 1

Upload: others

Post on 07-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

BenchValueWP4 - case study overview:

Ireland

Project meeting: Vienna, Austria. 23rd October, 2019

1

Page 2: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

Contents

• Overview of the Irish residential building stock

• Case study description

• Life Cycle Assessment results

• Conclusions

2

Page 3: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

Irish Residential Building Stock

3

0

100000

200000

300000

400000

500000

No.

Household

s

Construction Year

Detached house Semi- detached house

Terraced house Apartment

Bed-sit Not Stated

42%

28%

17%

12%

0% 1%Detachedhouse

Semi-detachedhouse

Terracedhouse

Apartment

Bed-sit

Source of data: Central Statistics Office [1]

Page 4: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

Irish Residential Building Stock

4Source timeline is based on [2]

Page 5: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

Case Study Building: 3 Bedroom Semi-Detached

Front Elevation Back Elevation5

Page 6: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

Case Study

Building

Ground Floor First Floor 6

Page 7: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

Case Study Building: Traditional Build

7

Source of image [3]

Page 8: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

Case Study Building: Insulated Concrete Formwork

8Source of images [4]

Page 9: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

Case Study Building: Timber Frame

9Source of images [5]

Page 10: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

Life Cycle Cost (A1-A5)

050

100150200250300350400

€/m

2

Building Element

Traditional Timber ICF

10

Page 11: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

Life Cycle Non-Renewable Energy (A1-A3)

0

200

400

600

800

1.000

1.200

MJ

/m2

Building Element

Traditional Timber ICF

11

Page 12: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

Life Cycle GHG Balance (A1-A3)

-60-40-20

020406080

100

kg

CO

2e

q./m

2

Building Element

Traditional Timber ICF

12

Page 13: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

Conclusions

• Concrete based superstructures are the predominant superstructure type in Ireland.

• Traditional based superstructure (concrete block cavity wall) is the cheaper option for building a semi-detached residential building.

• Timber frame based superstructure is the more environmentally friendly from a life cycle non-renewable energy and GHG balance perspective.

13

Page 14: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

References

14

[1] Central Statistics Office, “Housing in Ireland,” 2019. [Online]. Available:

https://statbank.cso.ie/px/pxeirestat/Database/eirestat/Profile 1 - Housing in Ireland/Profile 1 - Housing

in Ireland_statbank.asp?SP=Profile 1 - Housing in Ireland&Planguage=0. [Accessed: 18-Oct-2019].

[2] M. Badurek, M. Hanratty, B. Sheldrick, and D. Stewart, “Building Typology Brochure Ireland,” TABULA,

2014.

[3] Kingspan, “Kooltherm K8 Cavity Board: Partial Fill Cavity Wall Insulation,” Kingspan, 2018.

[4] Thermohouse, “Thermohouse,” 2019. [Online]. Available: https://thermohouse.ie. [Accessed: 27-Sep-

2019].

[5] Kingspan, “Kingspan Ultima Wall,” 2019. [Online]. Available: https://www.kingspan.com/irl/en-

ie/product-groups/engineered-timber-system/engineered-timber-frame-systems/our-

systems/wall/ultima. [Accessed: 27-Sep-2019].

Page 15: Outline of case study reports - benchvalue.efi.intbenchvalue.efi.int/uploads/documents/final-conference-vienna/4 Irish... · Project meeting: Vienna, Austria. 23rd October, 2019 1

15

Thank you!

Paul Moran

Jamie Goggins

Michael Clancy

Ken Byrne