FLUID & METERING Agriculture Chemical Processing Fuels & Energy Sanitary Water Pulsafeeder, Inc. 2883 Brighton-Henrietta Town Line Road Rochester, NY 14623 www.pulsa.com CUSTOMER : KUWAIT NATIONAL PETROLEUM COMPANY CONTRACTOR : M/s. AHMADIAH CONTG. AND TRADING CO. – KUWAIT ENGINEERING : M/s. PARAMOUNT LIMITED PROJECT TITLE : CB/PD/1123 REVAMP OF EFFLUENT TREATMENT FACILITIES (RETF) AT MAA/ MAB/ SHU REFINARY CONTRACT NUMBER : CB/PD/1123 REQUISITION NUMBER : R-CB/PD/1123/A-63-4-2053-E-B PUMP TAG NO. : P-22-104 A/B PUMP MODEL : 7660-S-E PUMP S/NO. : U705922-39, U705922-40 INDEX Sr.No. Document Title No. Pages 1 PUMP API DATASHEET 3 2 PUMP DATASHEET IN PULSAFEEDER FORMAT 1 3 PUMP GA DRAWING 1 4 PREDICTED PERFORMANCE CURVE 1 5 ELECTRICAL MOTOR DATASHEET 3 6 ELECTRICAL MOTOR GA DRAWING 1 7 MOTOR CURVES – (SPEED VS TIME, CURRENT VS SPEED & TORQUE VS SPEED) 3 8 ELECTRICAL MOTOR TEST REPORT 1 9 TECHNICAL DATASHEET FOR DISCHARGE PULSATION DAMPENER 1

Upload: suresh-ramanathan

Post on 27-Oct-2014

42 views

Category:

Documents


0 download

TRANSCRIPT

FLUID & METERING

AgricultureChemical Processing

Fuels & Energy Sanitary

Water

Pulsafeeder, Inc. 2883 Brighton-Henrietta Town Line Road Rochester, NY 14623 www.pulsa.com

CUSTOMER : KUWAIT NATIONAL PETROLEUM COMPANY

CONTRACTOR : M/s. AHMADIAH CONTG. AND TRADING CO. – KUWAIT

ENGINEERING : M/s. PARAMOUNT LIMITED

PROJECT TITLE : CB/PD/1123 REVAMP OF EFFLUENT TREATMENT FACILITIES (RETF) AT MAA/ MAB/ SHU REFINARY

CONTRACT NUMBER : CB/PD/1123

REQUISITION NUMBER : R-CB/PD/1123/A-63-4-2053-E-B

PUMP TAG NO. : P-22-104 A/B

PUMP MODEL : 7660-S-E

PUMP S/NO. : U705922-39, U705922-40

INDEX

Sr.No. Document Title No. Pages

1 PUMP API DATASHEET 3

2 PUMP DATASHEET IN PULSAFEEDER FORMAT 1

3 PUMP GA DRAWING 1

4 PREDICTED PERFORMANCE CURVE 1

5 ELECTRICAL MOTOR DATASHEET 3

6 ELECTRICAL MOTOR GA DRAWING 1

7 MOTOR CURVES – (SPEED VS TIME, CURRENT VS SPEED & TORQUE VS SPEED)

3

8 ELECTRICAL MOTOR TEST REPORT 1

9 TECHNICAL DATASHEET FOR DISCHARGE PULSATION DAMPENER 1

440V

PROJECT TITLE: CB/PD/1123 REVAMP OF EFFLUENT TREATMENT FACILITIES (RETF) AT MAA/MAB/SHU REFINERIESCONTRACT NUMBER: CB/PD/1123REQUISTION NUMBER: R-CB/PD/1123/A-63-4-2053-E-B Owner : KUWAIT NATIONAL PETROLEUM CO.(K.S.C.) Contractor : AHMADIAH CONTRACTING & TRADING CO. Engineering :PARAMOUNT LIMITED Vendor:

PUMP DATA SHEET/AS BUILT SR. NO. 6/33 REV 2 ESE 12/18/08 REVISED FOR FLOWS, TEST SECTION

S/N U705922-39-40: P-22-104 A/B NUTRIENT DOSING

����� ������ ���������������

� ��

���� ��� �������� ����� ��� ���� ������ ��������!���!�����������!���!����

���������� � �� ����� � �� �

����" ������ �����������

#������� �����

��#�" ����� ��������������� � ������ �� �� !����� ��������"�� ��� #�� "��������$

��"��"�� �#��

$�������

��#�� ����� �����

������� ���� �� ��#�� ���������������������������

������� ��� ������������������

��� ����������%"&�'��'����

����� ��������%'����

#�� #�% ����������� �����

�"�� ���&� �����������������

'������#

���#�������� ���� �� ��� ��

�"�� (��)���(�������

�"�� (���)���(�������

������% ������������(��� ��� ����"�

������% ������������(� ������

�������� %�&����

��"�#� ������������

&��� �������� * ������% �����

������ �����������( �� ����

&���������

��"�#� ��+���

�������������� �� � ���

�����

��# ��������(�������

&"&� ��������

%�� �������)�

����� ��+����(�� ����

��# ���������� �( ������

������ &"&� $����

������ &"&� ��+����(� ����

����� "��% ���(� ����

�#��"�� ����� &"&� ����%����(��������

#��� �%� &"&� $����

#��� �%� &"&� ��+����(� ����

����� �����������

������ ��������� ����������" #���" #�����

������ ��������� ��+����(��� ��

������ ��������� �"�%������ �� #���

#��� �%� ��������� ����������" #���" #�����

#��� �%� ��������� ��+����(��� ��

#��� �%� ��������� �"�%������ �� #���

�"

&"&������

&"&� . �� %������ #� � �#�� !*�����$

&"&� �� . %��#������

&"&� �������

��%�� �#�����

�� � . ��� �#�������� ��&����"

#�� �%��� #� � �#�� !*�����$

#�� �%� �����# � #��

#�� �%� %�������� ��&����"

������#�� �"��#��� � ��� ��&����"

"��

�������������� +������ � �+� ��������� , "��� �" �-

��"� 6��

�������������

��

����� �#�� ��� ����� &�"%���

�����" ��������

##����" ������8��������

�����"�

����������� � �%� �".�� ��� ������- # �� �" ������ ,

��� 6��

����" 6��

&�"%���

��"� "��% ��

��%�������% 6��

�����% 6��

�� ���� ! �� �����

�� ���� ! ��� #�% 6��

�� ���� ! �����% 6��

�������������

#��&�

���� ���������� ����� � +� � � �� ���

����( �

&�"%������

+����

� �����

����������

���������

���������

������������������

���� ����� ���������

���"������� �#�

���������#����) ��������� �� �/ �#�/ �������

���

������ ������

�� ����� ��"��" ���,������

������#�� ����

�����" �����������

��

������������,�� �� ��������,�� �����,�� ������������,���� ��� ���� ��������� �� ��� � ����������� �� ���� �������,�� ���� ��� �� �������������� ������ �������,�� ���� ������������� ������� ����������,�� ���� ����!��������

"����������,�� ����� ������ �� ��� ��, ��� ��� � � �(�(�(������ �� ��� ��,

�������

�� �� �����) ��������� ��" ���������� �� � ��) ���������� ��" ������������� ��� 0 �� �' 1 ��� ��� 0 �� �'���(��� ��� 1 � � ��� 0 �� �'������#���� ��" ���� �) '1 �� ��/ �1 �� �����/ ��,1 � �����"�� �����"��) "�������� ����� �� "������� +�#������

������������) �� ��������) �����+���� ��� ���� ��������) �� ��� � ����������) �� ���� �������+�� ����� ������ �������+�� ���� ������������) ������� ����������+�� �

#�������� +�� ����� ���� ��� �����)� )�+OTHER INFO : TESTING REQUIREMENT SHALL BE THE SAME AS SPECIFIED IN SUBMITTED API DATA SHEET

PROJECT TITLE: CB/PD/1123 REVAMP OF EFFLUENT TREATMENT FACILITIES (RETF) AT MAA/MAB/SHU REFINERIESCONTRACT NUMBER: CB/PD/1123REQUISTION NUMBER: R-CB/PD/1123/A-63-4-2053-E-B Owner : KUWAIT NATIONAL PETROLEUM CO.(K.S.C.) Contractor : AHMADIAH CONTRACTING & TRADING CO. Engineering :PARAMOUNT LIMITED Vendor:

GA DRAWING/AS BUILT SR.N0. 6/ 33FLANGE LOADING (SEE MOMENT) SR. NO. 9ESE REV 1 12/22/08REVISED FOR UNITS OF MEASURE

Vertical Load (Z) Moment (M) Transverse (X-Y)

39 lbs 44 in-lbs 3 lbs

S/N U705922-39-40: P-22-104 A/BNUTRIENT DOSING

PROJECT TITLE: CB/PD/1123 REVAMP OF EFFLUENT TREATMENT FACILITIES (RETF) AT MAA/MAB/SHU REFINERIESCONTRACT NUMBER: CB/PD/1123REQUISTION NUMBER: R-CB/PD/1123/A-63-4-2053-E-B Owner : KUWAIT NATIONAL PETROLEUM CO.(K.S.C.) Contractor : AHMADIAH CONTRACTING & TRADING CO. Engineering :PARAMOUNT LIMITED Vendor:

S/N U705922-39-40:P-22-104 A/BNUTRIENT DOSING

Document Title: Motor Data Sheet for SHU SSW Transfer Pump ( P-24-25 A B)

Ahmadiah Document No : R-CB/PD/1123/S-24-6-2053-E-BPAGE 1 OF 3

JOB NO CB/PD/1123 ITEM NO.(S) P-24-25 A & BREQ / SPEC NO. R-CB/PD/1123/S-24-6-2053-E-BPURCHASE ORDER NO. - DATE 19.05.08INQUIRY NO. - BY -

Requisition sheet for Design book No. : page:CAGE INDUCTION MACHINE Contr. job No. :

MESC No. :REQUIREMENTS AND CONDITIONS

Specific requirements : DEP 33.66.05.31-Gen. Rating : kW

Unit transformer included : No/…………. Speed : r/min

Pre-manufacturing meeting : Yes/No Direction of rotation : CW/ACW facing driving end

Preferred method Frame surface : IC4A1A1

of cooling Air to air : IC5A1A1

Supply system : 440V, 3-phase 50/60Hz IC6A1A1

: Max 25 KA Air to water

: Min 25 KA Type of mounting Horizontal : foot/flange

Max. duration of volt dip : 3 Sec. Vertical : foot/flange

Location : Land/Coastal/Offshore Number of starts per year : Nominal/………………..

Locked rotor current : to DEP/………………....

Ambient air temperature, min. : - 15 / -3 ° C Noise limitations at full load

Ambient air temperature, max. : 40 / 50 ° C (Max. sound pressure level) Special - see noise

Cooling water temp. min. : 5 / …………. ° C data sheet

Cooling water temp. max. : 30 / …………. ° C

Relative humidity, max. : 90%/ 100% Feeder cable Type

Tropical treatment required : Yes/No Size x mm

Direct sunlight : Yes/No Cable diam. Overlead/overall : / mm

Type of cable gland

Area classification : Zone 1/Zone 2/Non-Hazardous Anti-condensation heaters : Yes/No

Temperature classification : T3/ ……………… Heater supply voltage :

Gas group classification : IIA/ ……………… Aluminium frame allowed : Yes/No

Note: Permitted protection types (<22kW, non-hazardous, non-essential)

Ex'd' (IEC 79-1) Bearing temperature monitoring : Yes/No

Ex'p' (IEC79-2) Vibration monitoring

Ex'e' (IEC 79-7) Sleeve bearings - Proximity probes Yes/No

Ex'n' (IEC 70-15) Rolling element brgs. -SPM Yes/No

*** Not for hydrocarbon centrifugal or screw compressors Winding discharge monitoring Yes/No

Type : Production tests to be witnessed Yes/No

Moment of inertia : kgm2 Tests to be witnessed : Rotor balance Yes/No

Sample coil (HV) Yes/No

Torque/speed curve : Water coolers (HV) Yes/No

Type of coupling : Performance Test : Yes/No/Witnessed

Requisition Number : Routine test (HV only) : Yes/No/Witnessed

Special tests : Yes/No/Witnessed

Made Date EQUIPMENT : SHU SSW Transfer Pump Rev. letter

by: 19.05.08 Date

Chk'd Date PLANT : SHU Refinery Sign.

by:

Appr'd Date CONSIGNEE : Sheet No. 1 continued on sheet No. 2

by:

Eng. by : Equipm. No. P-24-25A/B-M

Principal : Req. No.

DEP 33.66.05.93-Gen., sheet 1/3, 12/2001

DL DL

A B

19.05.08 03.06.08AA

VKG19.05.08

DL19.05.08

DRIVEN EQUIPMENT

GENERAL BASIC REQUIREMENTS

CONSTRUCTION REQUIREMENTS

CONDITION MONITORING

INSPECTION AND TESTING

77 dB

V

Yes

Zone 1 Zone 2

Yes***

Yes***

Yes

Yes

Yes

LV only

No

SITE CONDITIONS

Supply system fault level:

EX PROTECTION

Page 1 of 3

Owner : KUWAIT NATIONAL PETROLEUM CO.(K.S.C.) Contractor : AHMADIAH CONTRACTING & TRADING CO. Engineering :PARAMOUNT LIMITED Vendor:

AL AHMADI,ABULLA & SHUAIBA REFINERIES CONTRACT NUMBER: CB/PD/1123 REQUISTION NUMBER: R-CB/PD/1123/A-63-42053-E-B

MOTOR DATA SHEETSR. NO. 3 REV 1 ESE 10/9/08

T705922-014

U705922-39-40: P-22-104 A/BNUTRIENT DOSING

Document Title: Motor Data Sheet for SHU SSW Transfer Pump ( P-24-25 A B)

Ahmadiah Document No : R-CB/PD/1123/S-24-6-2053-E-BPAGE 2 OF 3

JOB NO CB/PD/1123 ITEM NO.(S) P-24-25 A & BREQ / SPEC NO. R-CB/PD/1123/S-24-6-2053-E-BPURCHASE ORDER NO. - DATE 19.05.08INQUIRY NO. - BY -

Requisition sheet for Contr. job No. :

CAGE INDUCTION MACHINE MESC No. :

SPECIAL REQUIREMENTSNon-standard terminal box position :

Special tests :

At tender:Mass of motor (kg) Required

Moment of inertia 'j' (kg m2) Required

Lubrication requirements in case of force-lubricated bearings Required

Layout of terminal box Required

On receipt of order:Calculated critical speed (s) (1/min) Yes/No

Transient air-gap torque plots:

with two and three-phase short-circuit at the motor terminals, and with their respective frequencies over a

200 ms time period (Nm) Yes/No

Stalling times, hot and cold (s) Yes/No

Running-up times Yes/No

Dynamic model of motor to enable accurate flywheel sizing for reciprocating load and recommended flywheel size Yes/No

Rotor residual voltage time-constants and transient air-gap torques on reconnection after power interruption Yes/No

Heating/cooling time constants for thermal replica protection Yes/No

Maximum tolerable axial force Yes/No

Thermal endurance graphs showing insulation life versus temperature in the range including classes B and F;

such results shall be based on actual coils employing the Manufacturer's insulation system, tested to IEEE 117 or

IEEE 275 as appropriate. Yes/No

At testingSeverity of multiples of the supply frequency present in the vibration spectrum

Total all-in cost calculation require: Yes/No

Data to permit TAC calculation:

Capc Kot Ecost MDC

Electromagnetic compatibility restrictions

Made Date EQUIPMENT : SHU SSW Transfer Pump Rev. letter

by: 19.05.08 Date

Chk'd Date PLANT : SHU Refinery Sign.

by:

Appr'd Date CONSIGNEE : Sheet No. 2 continued on sheet No. 3

by:

Eng. by : Equipm. No. P-24-25A/B-M

Principal : Req. No.

DEP 33.66.05.93-Gen., sheet 2/3, 12/2001

DL DL

A B

19.05.08 03.06.08AA

VKG19.05.08

DL19.05.08

Page 2 of 3

Owner : KUWAIT NATIONAL PETROLEUM CO.(K.S.C.) Contractor : AHMADIAH CONTRACTING & TRADING CO. Engineering :PARAMOUNT LIMITED Vendor:

AL AHMADI,ABULLA & SHUAIBA REFINERIES CONTRACT NUMBER: CB/PD/1123 REQUISTION NUMBER: R-CB/PD/1123/A-63-42053-E-B

MOTOR DATA SHEET SR. NO. 3 REV 1 ESE 10/9/08

T705922-014

U705922-39-40: P-22-104 A/BNUTRIENT DOSING

Document Title: Motor Data Sheet for SHU SSW Transfer Pump ( P-24-25 A B)

Ahmadiah Document No : R-CB/PD/1123/S-24-6-2053-E-BPAGE 3 OF 3

JOB NO CB/PD/1123 ITEM NO.(S) P-87-900 A & BREQ / SPEC NO. R-CB/PD/1123/A-63-4-2051-E-BPURCHASE ORDER NO. - DATE 12.05.08INQUIRY NO. - BY -

Requisition sheet for Contr. job No. :

CAGE INDUCTION MACHINE MESC No. :

INFORMATION TO BE SUBMITTED BY MANUFACTURER

CONSTRUCTION DATAManufacturer: SIEMENS Allowable number of starts per year: …… 1000 Bearing Location: Endshield

Compliance with DEP 33.66.05.31-Gen. Full load current (FLC): …………………… 1.67 Bearing(s) DE make ORS

and requistion : Yes/No 1) SEE COMMENTS type 6205-2ZC3

Additional information required : 2) Power factor 100% / 75% load: … 0.77 clearanceC3

Main parts Country of origin/town Total/partly Efficiency 100% / 75% load 84 Bearing(s) NDE make ORS

Stator GERMANY Locked rotor current at Un/0.8 Un : ……% type 6004-2ZC3Rotor GERMANY Locked rotor torque at Un / 0.8 Un :…./ … clearanceC3

Pull up torque at Un/0.8 Un: …./…… % FLT N/A Bearing lifetime: ……… Hrs

Local service Name: KJ ELECTRIC Breakdown troque at Un/0.8: Un: …/…..% FLT Lubricant: Oil/grease GREASE

organisation Country/town: SYRACUSE, NY USA Shell type: ESSO UNIREX N3

Lub. System: SEALED

Sealing/regreasable/oilring/disc/forced

Type and frame number: 1LA9, 90S Running up time at Un / 0.8 Un: …./……..S Maximum relubrication interval: ………. Hrs

Rated voltage and frequency: 440V 50Hz VHz Allowable running up time at Un / 0.8 Un …/…….S N/A Min / Max oil flow: N/A- Rating: 0.75KW EEX-e motor to time: ……………………… S N/A Metallic cage bearing: yes/ …………… YES

- Full load speed: 1440 Vibration at no-load …………………. mm/s RMS N Axial float rotor: + …… mm/- …….. mm N/A

Direction of rotation facing driving end: Critical speed(s): ………………. r/min N/A Rotor balance grade : G1/ ………… N

CW/CCW/both BOTH Rotor inertia (J): ………………. Kgm2 Max axial force: …………… N N/A

Degree of protection of motor and auxiliaries: Max. sound pressure level at NO load: 48 dB(A) Bearing insulation provided: yes/no NO

IP 54/ ……IP55 Are noise correction measures used: yes/no NO Bearing bore diameter DE/NDE: ……… mm 25/20

Degree of protection of terminal boxes and bearings: (if yes, please state below) Stator frame: (Cast iron/steel) ALUM

IP 55/ …… IP55 Max. transient air gap torque when: Min. flywheel size (constant-torque load):

N/A ……...………… kgm2 N/A

Suitable for use in classified area: -two phase short circuit at motor terminals: Flywheel alternative and volt-dip duration:

Zone …… ZONE 2 EEX NA II ……………… kNm N/A ………………… kgm2, S N/A

- Template classification: T ………T3 -three phase short circuit at motor terminals: Magnetic slot wedges used yes/no

…………….. kNm N/A NO

- Gas group (if applicable): …………………… Magnetic slot wedges life years

Certification of Conformity available: Yes / ………YES -restart with full opposite residual voltage

possible: N/A

Type of protection of motor and auxiliaries: Yes/ ………………………. kNm HV cable connection : Bushing/Tail/ ……………..

IP55 N/A

Type of protection of terminal boxes: IP55 120 degree reconnection: ……….. kNm N/A Water cooler: Single tube / ……………….. N/AMethod of cooling: IC 4AIAI / ……IC4A1A1 Surplus water tubes: 20/ …………….. % N/A

Method of mounting: IM 1001 / …IM B3

Anti-Condensation heater rating …………… W N/A Stall time hot/cold: ……. / ………… S N/A Total net weight: …………………………… kg 15Proposed coupling fit : Keyed/Hydraulic/Integral KEYED Heating/cooling constants: …………………… N/A

Type Test results submitted ROUTINE

1) describe deviations LV performance test yes/no NOSEE COMMENTS ATTACHED HV sample coil test yes/no N/A

HV winding temp. rise yes/no N/A

2) Describe additional information required HV locked rotor current/torque yes/no N/A

Confirm testing to DEP yes/no NO

(list deviations below)

Noise reduction measures used:

Made Date EQUIPMENT : MAFP Spent Caustic Pump Rev. letter

by: 10.05.08 Date

Chk'd Date PLANT : MAA Sign.

by:

Appr'd Date CONSIGNEE : Sheet No. 3 continued on sheet No.

by:

Eng. by : Equipm. No. P-87-900A/B-M

Principal : Req. No. s

DEP 33.66.05.93-Gen., sheet 3/3, 12/2001

100000

20000

NOTES

ADDITIONAL INFORMATION

GENERAL PERFORMANCE DATA

INSPECTION AND TESTING

BASIC DATA

640%310%

320%

0.036

0.0033

DL

12.05.08

AAA B

12.05.08 03.06.08

DL12.05.08

VKGDL

Page 3 of 3

Owner : KUWAIT NATIONAL PETROLEUM CO.(K.S.C.) Contractor : AHMADIAH CONTRACTING & TRADING CO. Engineering :PARAMOUNT LIMITED Vendor:

AL AHMADI,ABULLA & SHUAIBA REFINERIES CONTRACT NUMBER: CB/PD/1123 REQUISTION NUMBER: R-CB/PD/1123/A-63-42053-E-B

MOTOR DATA SHEETSR. NO. 3 REV 1 ESE 10/9/08

T705922-014

U705922-39-40: P-22-104 A/BNUTRIENT DOSING

D1 - FV - SL

MO

TO

RD

IME

NSI

ON

AL

SR.N

O.6

RE

V1

ESE

10/9

/08

Ow

ne

r: K

UW

AIT

NA

TIO

NA

L PE

TRO

LEU

M C

O.(K

.S.C

.) C

on

tra

cto

r :

AH

MA

DIA

H C

ON

TRA

CTI

NG

& T

RA

DIN

G C

O.

Engin

eering :

PAR

AM

OU

NT

LIM

ITED

V

endor:

AL

AH

MA

DI,A

BU

LLA

& S

HU

AIB

A R

EFIN

ERIE

S C

ON

TRA

CT

NU

MB

ER: C

B/P

D/1

123

REQ

UIS

TIO

N N

UM

BER

: R-C

B/P

D/1

123/

A-6

3-42

053-

E-B

T70

5922

-014

S/N

U70

5922

-39-

40:P

-22-

104

A/B

NU

TRIE

NT

DO

SIN

G

MO

TOR

FR

AM

E :

IEC

90

curr

ent-s

peed

-cur

ve, d

irect

sta

rtin

gM

LF

B: 1LA

90904K

A90-Z

curr

ent at ra

ted s

yste

m v

oltage

curr

ent at vary

ing s

yste

m v

oltage

0

0.51

1.52

2.53

3.54

4.55

5.56

6.57

00.7

6

1.5

2

2.2

8

3.0

4

3.8

4.5

6

5.3

2

6.0

8

6.8

4

7.6

8.3

6

9.1

2

9.8

8

10

.64

01

50

30

04

50

60

07

50

90

01

05

01

20

01

35

01

50

0

0%

10

%2

0%

30

%4

0%

50

%6

0%

70

%8

0%

90

%1

00

%

speed in %

and a

bsolu

te

Pro

ject

na

me

: O

ffe

r n

o.:

Sie

me

ns-jo

b n

o.:

C

on

sig

nm

en

t-N

o.:

Clie

nt-

Ord

er-

no

.:It

em

-no

.:

Ow

ner

: KU

WA

IT N

ATI

ON

AL

PETR

OLE

UM

CO

.(K.S

.C.)

Contr

acto

r :

AH

MA

DIA

H C

ON

TRA

CTI

NG

& T

RA

DIN

G C

O.

Engin

eering :

PAR

AM

OU

NT

LIM

ITED

V

endor:

AL

AH

MA

DI,A

BU

LLA

& S

HU

AIB

A R

EFIN

ERIE

S C

ON

TRA

CT

NU

MB

ER: C

B/P

D/1

123

REQ

UIS

TIO

N N

UM

BER

: R-C

B/P

D/1

123/

A-6

3-42

053-

E-B

T70

5922

-014

RE

V 1

ESE

10/9

/08

S/N

U70

5922

-39-

40:P

-22-

104

A/B

NU

TRIE

NT

DO

SIN

G

spee

d-tim

e-cu

rve,

dire

ct s

tart

ing

MLF

B: 1LA

90904K

A90-Z

sta

rtin

g tim

e a

t ra

ted s

yste

m v

oltage

sta

rtin

g tim

e a

t vary

ing s

yste

m v

oltage

0

0.0

05

0.0

1

0.0

15

0.0

2

0.0

25

0.0

3

0.0

35

0.0

4

00.0

05

0.0

1

0.0

15

0.0

2

0.0

25

0.0

3

0.0

35

0.0

4

01

50

30

04

50

60

07

50

90

01

05

01

20

01

35

01

50

0

0%

10

%2

0%

30

%4

0%

50

%6

0%

70

%8

0%

90

%1

00

%

speed in %

and a

bsolu

te

Pro

ject

na

me

: O

ffe

r n

o.:

Sie

me

ns-jo

b n

o.:

C

on

sig

nm

en

t-N

o.:

Clie

nt-

Ord

er-

no

.:It

em

-no

.:

Ow

ne

r: K

UW

AIT

NA

TIO

NA

L PE

TRO

LEU

M C

O.(K

.S.C

.) C

on

tra

cto

r :

AH

MA

DIA

H C

ON

TRA

CTI

NG

& T

RA

DIN

G C

O.

Engin

eering :

PAR

AM

OU

NT

LIM

ITED

V

endor:

AL

AH

MA

DI,A

BU

LLA

& S

HU

AIB

A R

EFIN

ERIE

S C

ON

TRA

CT

NU

MB

ER: C

B/P

D/1

123

REQ

UIS

TIO

N N

UM

BER

: R-C

B/P

D/1

123/

A-6

3-42

053-

E-B

T70

5922

-014

RE

V 1

ESE

10/9

/08

S/N

U70

5922

-39-

40:P

-22-

104

A/B

NU

TRIE

NT

DO

SIN

G

torq

ue-s

peed

-cur

ve, d

irect

sta

rtin

gM

LF

B: 1LA

90904K

A90-Z

moto

r to

rque, ra

ted s

yste

m v

oltage

moto

r to

rque, vary

ing v

oltage

load torq

ue

0

0.51

1.52

2.53

3.54

02.4

85

4.9

7

7.4

55

9.9

4

12.4

25

14.9

1

17.3

95

19.8

8

0150

300

450

600

750

900

1050

1200

1350

1500

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

sp

ee

d in

min

-1 a

nd

sp

ee

d/s

yn

ch

ron

ou

s s

pe

ed

in

%

Pro

ject

na

me

: O

ffe

r n

o.:

Sie

me

ns-jo

b n

o.:

C

on

sig

nm

en

t-N

o.:

Clie

nt-

Ord

er-

no

.:It

em

-no

.:

MO

TO

RSP

EE

DV

ST

OR

QU

ESR

.NO

.4R

EV

1E

SE10

/9/0

8O

wn

er

: KU

WA

IT N

ATI

ON

AL

PETR

OLE

UM

CO

.(K.S

.C.)

Co

ntr

acto

r :

AH

MA

DIA

H C

ON

TRA

CTI

NG

& T

RA

DIN

G C

O.

Engin

eering :

PAR

AM

OU

NT

LIM

ITED

V

endor:

AL

AH

MA

DI,A

BU

LLA

& S

HU

AIB

A R

EFIN

ERIE

S C

ON

TRA

CT

NU

MB

ER: C

B/P

D/1

123

REQ

UIS

TIO

N N

UM

BER

: R-C

B/P

D/1

123/

A-6

3-42

053-

E-B

T70

5922

-014

S/N

U70

5922

-39-

40:P

-22-

104

A/B

NU

TRIE

NT

DO

SIN

G

T705922-014MOTOR TESTRESULTS SR. NO. 24REV 0 ESE 12/16/08

Owner : KUWAIT NATIONAL PETROLEUM CO.(K.S.C.) Contractor : AHMADIAH CONTRACTING & TRADING CO. Engineering :PARAMOUNT LIMITED Vendor:

AL AHMADI,ABULLA & SHUAIBA REFINERIES CONTRACT NUMBER: CB/PD/1123 REQUISTION NUMBER: R-CB/PD/1123/A-63-42053-E-B

S/N U705922-39-40: P-22-104 A/BNUTRIENT DOSING

EXPLODED VIEWSENTRY MODEL CT2420HF

SENTRY MODEL #: CT2420HFMAXIMUM PRESSURE: 275 PSI/18.9 BARCAPACITY: 370 CUBIC INCHES/6.06 LITERSWETTED HOUSING: 316L STAINLESS STEELNONWETTED HOUSING: 316L STAINLESS STEELBLADDER: HYPALONINLET: 2" 150# RAISED FLANGEAIR CONTROL: CHARGEABLE

ITEM DIMENSIONAL DRAWING

TOLERANCE ± .25"

BLACOH FLUID CONTROL, INCRIVERSIDE, CA 92507 USA

TEL: 800.603.7867 or 951.342.3100 Fax: 951.342.3101

E-mail: [email protected] web site: www.blacoh.com

ALTHOUGH THE INFORMATION ON THIS SHEET IS BELIEVED TO HAVE BEEN ACCURATE WHEN THE SHEET WAS FIRST PREPARED, SOME INFORMATION ON THIS SHEET MAY NOT BE ENTIRELY ACCURATE NOW. PLEASE VERIFY MATERIAL COMPONENTS, DIMENSIONS, AND PRESSURE RATING ON THE CURRENT BROCHURE FOR THIS PRODUCT BY BLACOH FLUID CONTROL, INC. (“BLACOH”) OR, IF NECESSARY, CONTACT BLACOH DIRECTLY. PRESSURE TOLERANCES, INCLUDING BUT NOT LIMITED TO, ON MODELS MADE OF PLASTIC, MAY BE REDUCED BY TEMPERATURE VARIATION AND BY THE COMPOSITION OF THE SUBSTANCE BEING PUMPED.

USE OF AN INCOMPATIBLE OR UNSUITABLE DAMPENER ON A PUMP MAY BE DANGEROUS TO PERSONS AND PROPERTY. BY WAY OF EXAMPLE BUT NOT LIMITATION, USE OF AN INCOMPATIBLE OR UNSUITABLE DAMPENER MAY RESULT IN EXPLOSIONS, LEAKAGE OF LIQUIDS OR GASES (WHICH MAY BE HAZARDOUS), OR MALFUNCTIONING EQUIPMENT.

THE USER IS SOLELY REPSONSIBLE FOR (AND BLACOH IS NOT RESPONSIBLE FOR) VERIFYING THE COMPAITIBILITY AND SUITABILITY OF A PARTICULAR DAMPENER FOR A PARTICULAR PUMP AND APPLICATION. AS WELL AS DETERMINING WHETHER TESTING OF A DAMPENER IS ADVISABLE PRIOR TO USE IN A PARTICULAR APPLICATION.

2" 150 # RF FLANGE

PROJECT TITLE: CB/PD/1123 REVAMP OF EFFLUENT TREATMENT FACILITIES (RETF) AT MAA/MAB/SHU REFINERIESCONTRACT NUMBER: CB/PD/1123REQUISTION NUMBER: R-CB/PD/1123/A-63-4-2053-E-B Owner : KUWAIT NATIONAL PETROLEUM CO.(K.S.C.) Contractor : AHMADIAH CONTRACTING & TRADING CO. Engineering :PARAMOUNT LIMITED Vendor:

S/N U705922-39-40: P-22-104 A/B NUTRIENT DOSING

T705922-005ACCESSORY DWG 6 REV 0 ESE 7/21/08