Submittal Data: PEaD-a24aa4 & PuY-a24NHa4 (-bS) 24,000 btu/H HorizoNtal-DuctED air coNDitioNiNg SYStEm
gENEral FEaturES• Horizontal-ductedindoorunitfeaturesmediumstaticpressurecapability• Thinbody:9-7/8”high• Built-indrainmechanismforcondensateremoval;liftsto27-9/16"• Airfilterisincludedwithindoorunit• Quietoperation—bothindoorandoutdoorunits• Automaticfanspeedcontrol• Autorestartfollowingapoweroutage• Self-checkfunction—integrateddiagnostics• Knockoutforventilationair• Limitedwarranty:fiveyearspartsandsevenyearscompressors
oPtioNal accESSoriESindoor unit□ FilterBoxwithMERV13Filters(FBM2-3)
outdoor unit□ DrainPan(PAC-SG64DP)□ DrainSocket(PAC-SG61DS)□ Three-poleDisconnectSwitch(TAZ-MS303)□ WindBaffle(WB-PA2)□ AirOutletGuide(PAC-SG59SG□ MountingBase(DSD-400N)□ MountingPad(ULTRILITE2)□ Wall-mountingBrackets(CWMB1)
controller options□ WirelessWall-mountedRemoteControllerKit(MHK1)*□ PortableController(MCCH1)*□ OutdoorAirSensor(MOS1)*
*SeeSubmittalforinformationoneachoption.□ Wall-mountedWiredRemoteController(PAR-21MAAU)□ M-NETAdapter(PAC-SF81MA)□ CN51ConnectorforMultipleRemoteControllerAdapters/DuctFanController(PAC-725AD)□ CN32ConnectorforRemoteOn/Off(PAC-715AD)□ RemoteTemperatureSensor(PAC-SE41TS)□ RemoteOperationAdapter-DisplayandOn/Off(PAC-SF40RM)□ Hand-heldWirelessRemoteController(PAR-FL32MA;req.PAR-FA32MA-E)□ WirelessSignalReceiverModule(PAR-FA32MA-E)□ LockdownBracketforHand-heldController(RCMKP1CB)□ Control/ServiceTool(PAC-SK52ST)
Outdoor Unit: PUY-A24NHA4 (-BS)
SEacoaSt ProtEctioN• ExternalOuterPanel:Phosphatecoating+Acrylic-Enamelcoating• FanMotorSupport:Epoxyresincoating(atedgeface)• SeparatorAssembly;ValveBed:Epoxyresincoating(atedgeface)• Screws(usedouterside):Zincnickelcoating5μm+Polyvinylidenechloridecoating
“blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants..
uNit oPtioN□ StandardModel……………..........…….................PUY-A24NHA4□ SeaCoast (BS)Model…….…………………..PUY-A24NHA4-BS
Indoor Unit: PEAD-A24AA4
SPECIFICATIONS: PCA-A24KA4 & PUY-A24NHA4
Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc.
Notes:
cooling*RatedCapacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24,000Btu/hMinimumCapacity . . . . . . . . . . . . . . . . . . . . . . . . . . . .12,000Btu/hSEER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16.0Btu/h/WEER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.0Btu/h/WTotalInput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,400W
Electrical requirementsPowerSupply . . . . . . . . . . . . . . . . . . . . 208/230V,1-Phase,60HzRecommendedFuse/BreakerSize. . . . . . . . . . . . . . . . . . . . . . 25A
VoltageIndoor-OutdoorS1-S2 . . . . . . . . . . . . . . . . . . . . . . AC208/230VIndoor-OutdoorS2-S3 . . . . . . . . . . . . . . . . . . . . . . . . . . .DC±24V
oPEratiNg coNDitioNSIndoorIntakeAir
Temp.OutdoorIntakeAir
Temp.
CoolingMaximum 95ºF(35ºC)DB
71ºF(22ºC)WB 115ºF(46ºC)DB
Minimum 67ºF(19ºC)DB57ºF(14ºC)WB 0ºF**(-18ºC)DB
**Withoptionalwindbaffleaccessoryinstalled.Ifnotinstalled,theminimumtemperaturewillbe23ºF(-5ºC)DB.
indoor unitMCA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.63AFanTypexQuantity . . . . . . . . . . . . . . . . . . . . . . . . . Siroccofanx2FanMotorType . . . . . . . . . . . . . Direct-drivenDCBrushlessMotorBlowerMotor(ECM). . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.10F.L.A.FanMotorOutput . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121WAirflow(Lo-Mid-Hi). . . . . . . . . . . . . . . . 512-636-742DryCFM 494-600-671WetCFMAirFilter . . . . . . . . . . . . . . . . . . . . . . . . .PolypropyleneHoneycombExternalStaticPressure. . . . . . 0.14-0.20-0.28-0.40-0.60"WGSoundPressureLevel(Lo-Mid-Hi) . . . . . . . . . . 30-33-37dB(A)SHF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.68MoistureRemoval. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.9pt./h
DimENSioNS uNit iNcHES / mmW 43-5/16/1,100D 28-7/8/732H 9-7/8/250Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73lbs./33kgExternalFinish. . . . . . . . . . . . . . . . . . . . . . .Galvanized-steelSheetFieldDrainpipeSizeO.D. . . . . . . . . . . . . . . . . . . . . . 1-1/4"/32mm outdoor unitCompressor . . . . . . . . . . . . . . . . . . .DCInverter-drivenTwinRotaryMCA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . …18AMOCP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30AFanMotor(ECM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.75F.L.A.SoundPressureLevel(Cooling). . . . . . . . . . . . . . . . . . . . . 48dB(A)
DimENSioNS iNcHES / mmW 37-3/8/950D 13+1-3/16/330+30H 37-1/8/943
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163lbs./74kgExternalFinish. . . . . . . . . . . . . . . . . . . . . . MunsellNo.3Y7.8/1.1RefrigerantType . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R410ARefrigerantPipeSizeO.D.GasSide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5/8"/15.88mmLiquidSide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/8"/9.52mmMax.RefrigerantPipeLength. . . . . . . . . . . . . . . . . . . . . 165'/50mMax.RefrigerantPipeHeightDifference . . . . . . . . . . . . 100'/30mConnectionMethod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flared
SPECIFICATIONS : PEAD-A24AA4 & PUY-A24NHA4 (-bS)
* rating conditions per aHri Standard Cooling|Indoor:80ºF(27ºC)DB/67ºF(19ºC)WBCooling|Outdoor:95ºF(35ºC)DB/75ºF(24ºC)WB
Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc.
INDOOr UNIT PEAD-A24AA4 FAN PErFOrmANCE AND AIrFlOw rATES
0[0]
10[0.040]
20[0.080]
30[0.120]
40[0.161]
50[0.201]
60[0.241]
Airflow rate (m3/min)[cfm]
Ext
erna
l sta
tic p
ress
ure
(Pa)
[in.W
G]
10[353]
15[530]
20[706]
25[883]
30[1059]
0[0]
50[0.201]
100[0.401]
150[0.602]
Airflow rate (m3/min)[cfm]
Ext
erna
l sta
tic p
ress
ure
(Pa)
[in.W
G]
10[353]
15[530]
20[706]
25[883]
30[1059]
0[0]
10[0.040]
20[0.080]
30[0.120]
40[0.161]
50[0.201]
60[0.241]
70[0.281]
Airflow rate (m3/min)[cfm]
Ext
erna
l sta
tic p
ress
ure
(Pa)
[in.W
G]
10[353]
15[530]
20[706]
25[883]
30[1059]
0[0]
10[0.040]
20[0.080]
30[0.120]
40[0.161]
50[0.201]
60[0.241]
70[0.281]
80[0.321]
90[0.361]
Airflow rate (m3/min)[cfm]
Ext
erna
l sta
tic p
ress
ure
(Pa)
[in.W
G]
10[353]
15[530]
20[706]
25[883]
30[1059]
0[0]
50[0.201]
100[0.401]
150[0.602]
200[0.803]
Airflow rate (m3/min)[cfm]
Ext
erna
l sta
tic p
ress
ure
(Pa)
[in.W
G]
10[353]
15[530]
20[706]
25[883]
30[1059]
Limit
Low
Middle
High
Rated point
Limit
Low
Middle
High
Rated point
Limit
Low
Middle
High
Rated point
Limit
Low
Middle
High
Rated point
Limit
Low
Middle
High
Rated point
PEAD-A24AA4(External static pressure 35Pa [0.14 in. WG]) 208-230V 60Hz
PEAD-A24AA4(External static pressure 50Pa [0.2 in. WG]) 208-230V 60Hz
PEAD-A24AA4(External static pressure 70Pa [0.3 in. WG]) 208-230V 60Hz
PEAD-A24AA4(External static pressure 100Pa [0.4 in.WG]) 208-230V 60Hz
PEAD-A24AA4(External static pressure 150Pa [0.6 in. WG]) 208-230V 60Hz
Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc.
DImENSIONS: PEAD-A24AA4
3-ø
2.9(
1/8)
mou
ntin
g ho
le
Air
filte
r
Ref
riger
ant p
ipin
gfla
re c
onne
ctio
n (li
quid
)
Liqu
id p
ipe
Gas
pip
e
ø9.
52 (
3/8)
ø15
.88
(5/
8)
Ven
tilat
ion
air
inta
ke ø
100(
3-15
/16)
knoc
k ou
t hol
e
AM
odel
1400
1100
PE
AD
-A24
, 30A
A4
PE
AD
-A36
, 42A
A4
GF
BC
DE
1000
1413
6015
0014
54
1154
1060
1112
00
1300
1358
1058
Sus
pens
ion
bolt
hole
4-14
x30(
9/16
X1-3
/16)
Slo
t
(O.D
.ø32
(1-1
/4))
Dra
in p
ipe
Dra
in p
ipe(
O.D
.ø32
(1-1
/4))
(Spo
ntan
eous
dra
inin
g)
Ter
min
al b
lock
(Rem
ote
cont
rolle
r tr
ansm
issi
on li
ne)
Ter
min
al b
lock
(Ind
oor/
Out
door
con
nect
ion
line)
Con
trol
box
Drain
pum
p
Ref
riger
ant p
ipin
gfla
re c
onne
ctio
n (g
as)
1
12
2
Dra
in p
ipe(
O.D
. ø32
(1-1
/4))
(E
mer
genc
y dr
aini
ng)
2xE
-ø2.
9(1/
8)
Air
inle
tA
irou
tlet
2X2-
ø2.
9(1/
8)
(4-1
5/16
)ø
125
120
120
57(2-1/4)
78(3-1/8)
200(7-7/8)
378(
12-7
/16)
Uni
t:mm
(in.)
(43-
5/16
)
(55-
1/8)
(57-
1/4)
(45-
7/16
)(4
7-1/
4)
(59-
1/16
)(5
3-9/
16)
(41-
3/4)
(39-
3/8)
(51-
3/16
)(5
3-1/
2)
(41-
11/1
6)
21(7/8)
(8-5
/16)
(5-3/8)135
153
(6-1
/16)
(2-1
1/16
)(5
-3/8
)(Sus
pens
ion
bolt
pitc
h)
21G
18(3
/4)
210
40(1-5/8) 40(1-5/8)
250(9-7/8)
40(1-5/8)
33(1-5/16)122(4-13/16)
D(Duct) 20(13/16)
100(3-15/16)X(E-1)=F 30(1-3/16)
100(3-15/16)
217(8-9/16)
41(1-5/8)
100(3-15/16)
356
(1/1
6)6713
6
732
(28-
7/8)
700
(27-
9/16
)32
(1-5
/16)
238(
9-3/
8)
10(7
/16)
23(15/16) 178(7-1/16)
643
(25-
3/8)
23(15/16)
C
B(Suspension bolt pitch)
A
10(7
/16)
57(2
-1/4
)
58(2-5/16)
15(5
/8)
Not
e 4
10 1212
80
330
449 54
320
5
990
ML
KJ
N12
00
1500H
N-ø
2.9(
1/8)
(4-7/16)(4-7/16)
(50-
7/16
)
(39)
(12-
5/8)
(13)
(1-1
5/16
)
(2-3
/16)
(59-
1/16
)
(47-
1/4)
-7/1
60
(2-9
/16
)
(11-
13/1
6)
(27-9/16)
(11-
13/1
6)(9
-7/8
~11-
13/1
6)
Less than 700
Less
than
300
(Act
ual l
engt
h)
65 0 -1
0
JK
X(L
-1)=
MJ
6(1
/4)
11211211(7/16)
K
50(2
)
250~
300
450(
17-3
/4)
50(2
)
H
777(
30-5
/8)
450(
17-3
/4)
Mor
e th
an 3
00
More than 20(13/16)
More than 10(7/16)
<ac
cess
ory>
Drai
n ho
se (I
.D.ø
32(1
-1/4
))
Acc
ess
door
Not
e2
Mak
e th
e ac
cess
doo
r at t
he a
ppoi
nted
pos
ition
pro
perly
for s
ervi
ce m
aint
enan
ce.
Cei
ling
surf
ace
Acc
ess
door
Req
uire
d sp
ace
for
serv
ice
and
mai
nten
ance
NOTE 1. Use M10 screw for the Suspension bolt (field supply). 2. Keep the service space for the maintenance at the bottom. 3. This chart indicates for PEAD-A24·30·36·42AA4 models,which have 2 fans. 4. In case of the inlet duct is used, remove the air filter (supplied with the unit), then install a filter (field supplied) at suction side.
Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc.
3400 Lawrenceville Suwanee RdSuwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822www.mehvac.com